1
Surface Diagram Solar Green Roof lowers the ambient temperture of the roof optimizing the soalr panels efficiency. Total number of solar panels: 323 = 422.484kwh/per day CONNECTIVITY Architecture in the urban setting should have a range of connections between interior and exterior instead of a singular connection. The interior/exterior connection is influenced by a range of spaces within the solid/void relationship. These spaces should create an experiential, physical, and visual relationship of interior and exterior. Within the built environment there should be a range of spaces that establish multiple connections between interior and exterior. Zinco Solar Green Roof In order from top to bottom: -Solar Panel -Solar Panel Mounting structure -Plant (Buffalo grass) -Growing medium Zinco Blend-E (Depth 4”) -Zinco filter sheet -Zinco water storage and drainage element Floradrain FD 25 -Zinco moisture retention and protection may SSM45 -Zinco root barrier WSF40 -Roof Construction - Steel structure, steel Decking, Concrete Pedestrian-Oriented Hardscape Located at 2nd Floor Linear Courtyard Solar Green Roof and Green Roof Green Roof llocated at 3rd floor Summer Solstice Winter Solstice Variable Refrigerant Flow System Insulated Metal Wall Panel Louvered Window Overhang Solar Shading System Louvered Cutain Wall Solar Shading System Channel Glass Curtain Wall Solar Green Roof Energy Recovery Ventilator Lafayette, Louisiana
Transcript
Page 1: CONNECTIVITY - AIA Houston · 2018-05-01 · Solar Green Roof lowers the ambient temperture of the roof optimizing the soalr panels efficiency. Total number of solar panels: 323 =

Surface DiagramSolar Green Roof lowers the ambient temperture of the roof optimizing the soalr panels efficiency.Total number of solar panels: 323 = 422.484kwh/per day

CONNECTIVITYArchitecture in the urban setting should have a range of connections between interior and exterior instead of a singular connection. The interior/exterior connection is influenced by a range of spaces within the solid/void relationship. These spaces should create an experiential, physical, and visual relationship of interior and exterior. Within the built environment there should be a range of spaces that establish multiple connections between interior and exterior.

Zinco Solar Green RoofIn order from top to bottom:-Solar Panel-Solar Panel Mounting structure-Plant (Buffalo grass)-Growing medium Zinco Blend-E (Depth 4”)-Zinco filter sheet-Zinco water storage and drainage element Floradrain FD 25-Zinco moisture retention and protection may SSM45-Zinco root barrier WSF40-Roof Construction - Steel structure, steel Decking, Concrete

Pedestrian-OrientedHardscape Located at 2nd FloorLinear Courtyard

Solar Green Roofand Green Roof

Green Roof llocatedat 3rd floor

Summer Solstice

Winter Solstice

Variable Refrigerant Flow System

Insulated Metal Wall Panel

Louvered Window Overhang Solar Shading System

Louvered Cutain WallSolar Shading System

Channel Glass Curtain Wall

Solar Green Roof

Energy Recovery Ventilator

Lafayette, Louisiana