UPS monitoring and management through web browsers and web enabled portable devices – no special software required
Enterprise wide monitoring with SNMP
Operating system shutdown with NetWatch agent or LanSafe 5 software
Load segment control
E-mail capability
Remote upgrades and configuration
Event and data logs stored in the adapter
Graphical meter data view applet
10/100 Mb networks supported (autosensing)
Optional Environmental Monitoring Probe for temperature, humidity and 2 contact inputs
•
•
•
•
•
•
•
•
•
•
ConnectUPS Web/SNMP Cards
ConnectUPS Web/SNMP
network adapters are the most
powerful and flexible way to
manage and monitor UPSs in a
computer network environment.
Web interface shows current
status of the UPS at a glance,
while also storing data in its
memory for future reference.
SNMP protocol interfaces the
card to network management
systems such as HP OpenView,
IBM Director and many more.
If necessary, the card can
initiate a controlled shut
down of up to 256 computers.
The shutdown agent called
NetWatch is able to execute
tasks and inform users before
shutting down the operating
system. NetWatch is available
for Windows, Novell, MacOS
X and major Unix platforms.
The new LanSafe 5 network
shutdown software is also
compatible with ConnectUPS
Web/SNMP cards.
Monitoring, control and shutdown
Product SnapshotType: TCP/IP network adapter for Powerware UPSsInstallation: Hot-pluggableOperating Systems: NetWatch supports Windows, Novell, MacOS X and several Unixes including LinuxAdditional features: 3-port switching hub (ConnectUPS-X) and optional environmental monitoringUpgrades: Upgrades available at www.powerware.com
Features
In case of an alarm the
adapter can notify system
administrators in many ways.
An email can be sent using its
SMTP function, NetWatch can
create pop up messages on
user terminals and SNMP traps
will alert network management
systems.
The optional Environmental
Monitoring Probe provides
temperature and humidity
sensors as well as two relay
inputs which can be used
to detect intrusions, water
leaks, smoke and fire alarms.
Environmental data can be also
used to trigger an automatic
operating system shutdown
with NetWatch.
With ConnectUPS Web/SNMP
cards it is possible to remotely
turn off and on UPS outputs
perhaps to reboot attached
devices. Battery tests can also
be initiated via web or SNMP.
ConnectUPS Web/SNMP Cards come in three physical forms:
Mailing address:Powerware Products and Services,MarketingP.o. Box 54, 02921 Espoo, FINLANDTel: +358 9 452 661Fax: +358 9 452 [email protected] http://www.powerware.com
DENMARKTel: +45 3686 [email protected]
FINLANDTel: +358 9 452 [email protected]
FRANCETel: +33 1 60 12 74 [email protected]
GERMANYTel: +49 7841 [email protected]
ITALYTel: +39 02 66 04 05 [email protected]
NORWAYTel: +47 23 03 65 50 [email protected]
POLANDTel: +48 22 331 85 [email protected]
RUSSIATel: +7 095 787 [email protected]
SWEDENTel: +46 8 598 940 [email protected]
UNITED KINGDOMTel: +44 1753-608 [email protected]
In the interests of continual product improvement all specifications are subject to change without notice.Powerware®, Hot Sync®, Advanced Battery Management, LanSafe, PowerVision, and FORESEER are trademark(s) of Eaton Power Quality Corporation. © 2005 Eaton Corporation
1017974 Rev B 8/2005
Technical specifications
ConnectUPS Web/SNMP Cards
Network connection 10/100BaseT RJ-45 (ConnectUPS-X has a built-in hub which provides 3 additional connectors for other devices)
UPS Protocol Powerware UPS protocols (XCP, UPSCode II)
Network protocol User: HTTP, SMTP, SNMPSystem: DHCP (BootP), ARP, RARP, TFTP
SNMP MIBs Powerware PowerMIB (XUPS.MIB)Standard UPS MIB RFC 1628 (stdupsv1.mib)
Operating temperature 0 – 40°C
Operating humidity 10 – 80 %, noncondensing
Power input ConnectUPS-X and -BD: 9 V DC, from slotConnectUPS-E : 12 V DC
Power consumption 3.5 W maximum
Size ConnectUPS-X: 120 x 114 x 39 mmConnectUPS-BD: 134 x 81 x 33 mmConnectUPS-E: 134 x 90 x 30 mm
Weight 200 g
Supported Operating Systems for NetWatch shutdown
• Windows 9x/Me/NT4/2000/XP/2003• Novell NetWare• MacOS X• Several Unix variants, including Linux
Environmental Monitoring Probe
(option for the 100 mbit ConnectUPS Web/SNMP adapters, requires fw 3.01 or higher)
Temperature measurement 0-80°C, accuracy ±1°C
Humidity measurement 10-90 %, accuracy ±5%
Power input 12 VDC (from the ConnectUPS Web/SNMP card)
Dimensions 58 x 38 x 30 mm
Weight 34 g
ConnectUPS-E Web/SNMP adapter (External for 9305)Part number 103003535-5501
ConnectUPS-BD Web/SNMP card (for 9120)Part number 103002973-5501
ConnectUPS-X Web/SNMP card (XSlot; for 9390/9370/9355/9155/9125/5125/5115RM)Part number 103002974-5501
Environmental Monitoring Probe (EMP)Part number 103003637-5501