ARCHITECT OWNER HKS ARCHITECTS, INC. 90 SOUTH 400 WEST, SUITE 110 SALT LAKE CITY, UT 84101 STATE OF UTAH DIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDING SALT LAKE CITY, UTAH 84114 HKS PROJECT # 22564.000 MECHANICAL ENGINEER VAN BOERUM & FRANK 330 SOUTH 300 WEST SALT LAKE CITY, UTAH 84111 ELECTRICAL ENGINEER BNA CONSULTING 635 SOUTH STATE STREET SALT LAKE CITY, UTAH 84111 STATE OF UTAH DIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT AND THE UTAH NATIONAL GUARD STRUCTURAL ARW ENGINEERS 1594 PARK CIRCLE OGDEN, UTAH 84404 14 FEBRUARY 2020 CONSTRUCTION DOCUMENTS BUILDING 4141 RENOVATIONS
Transcript
Page 1: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

ARCHITECT

OWNER

HKS ARCHITECTS, INC.

90 SOUTH 400 WEST, SUITE 110

SALT LAKE CITY, UT 84101

STATE OF UTAH

DIVISION OF FACILITIES CONSTRUCTION

AND MANAGEMENT

4110 STATE OFFICE BUILDING

SALT LAKE CITY, UTAH 84114

HKS PROJECT # 22564.000

MECHANICAL ENGINEER

VAN BOERUM & FRANK

330 SOUTH 300 WEST

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

BNA CONSULTING

635 SOUTH STATE STREET

SALT LAKE CITY, UTAH 84111

STATE OF UTAH

DIVISION OF FACILITIES

CONSTRUCTION AND MANAGEMENT

AND THE UTAH NATIONAL GUARD

STRUCTURAL

ARW ENGINEERS

1594 PARK CIRCLE

OGDEN, UTAH 84404

14 FEBRUARY 2020CONSTRUCTION DOCUMENTS

BUILDING 4141 RENOVATIONS

Page 2: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

DRAWING ABBREVIATIONS INDEX OF DRAWINGS

LEGEND

A

AB ANCHOR BOLTAD AREA DRAINAC AIR CONDITIONINGACT ACOUSTICAL CEILING TILEADD ADDENDUMADD'L ADDITIONALADJ ADJACENTAFF ABOVE FINISHED FLOORAGGR AGGREGATEAL ALUM ALUMINUMALT ALTERNATEANOD ANODIZEDAPPROX APPROXIMATEARCH ARCHITECTURAL

B

B.M. BENCH MARKBD BOARDBETW BETWEENBF BACKFACEBG BUMPER GUARDBL BED LOCATORBL BUILDING LINEBLDG BUILDINGBLKG BLOCKINGBM BEAMBOT BOTTOMBR BUMPER RAILBRG BEARINGBSMT BASEMENTBU ROD BACK-UP RODBUR BUILT-UP ROOFBW BEARING WALL

C

C COMPACT PARKING SPACECC CUBICK CURTAINCDR CARD READERCEM CEMENTCER CERAMICCG CORNER GUARDCIP CAST IN PLACECJ CONTROL JOINTCJ CONSTRUCTION JOINTCL CENTER LINECLG CEILINGCLR CLEARCMU CONCRETE MASONRY UNITCOL COLUMNCOMM COMMUNICATIONSCONC CONCRETECONN CONNECTIONCONST CONSTRUCTIONCONT CONTINUOUSCOORD COORDINATECPE CHLORINATED POLYETHYLENECOOR CORRIDORCR COLD ROLLEDCR CRASH RAILCSK COUNTERSUNKCT CERAMIC TILECTD CENTEREDCTR CENTERCW CURTAIN WALL

D

D DEPTHDBA DEFORMED BAR ANCHORDET DETAILDF DECORATIVE FILMDIA DIAMETERDIAPH DIAPHRAGMDIM DIMENSIONDJ DEFLECTION JOINTDL DEAD LOADDN DOWNDRG DRAWINGDS DOWN SPOUTDWGS DRAWINGSDWLS DOWELS

E

EA EACHEF EACH FACEEFG ENTRANCE FLOOR GRILLEEIFS EXTERIOR INSULATION AND

FINISH SYSTEMEJ EXPANSION JOINTEL ELEVATIONELEC ELECTRICELEV ELEVATOREOS EDGE OF SLABEQ EQUALEQUIP EQUIPMENTESC ESCALATOREW EACH WAYEWC ELECTRIC WATER COOLEREXIST EXISTINGEXP BLT EXPANSION BOLTEXT EXTERIOR

F

FD FLOOR DRAINFDN FOUNDATIONFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFF FINISH FLOORFHC FIRE HOSE CABINETFIB FIBERGLASSFIN FINISHFLR FLOORFS FAR SIDEFT FOOTFT FLOOR TRANSITIONFTG FOOTINGFV FIELD VERIFYFVC FIRE VALVE CABINET

G

GA GAUGEGALV GALVANIZEDGB GRADE BEAMGEN GENERALGFRC GLASS-FIBER REINFORCED

CONCRETEGI GALVANIZED IRONGL GLASSGM GLAZED MASONRY UNITGND GROUNDGR GRADEGRG GLASS-REINFORCED GYPSUMGYP BD GYPSUM BOARD

H

HB HOSE BIBHDW HARDWAREHDWD HARDWOODHK HOOKHM HOLLOW METALHOR HORIZONTALHP HIGH POINTHR HOURHS HEADED STUDHSKP HOUSEKEEPINGHT HEIGHTHW HAND WASHHW HEAD OF WALL

I

IBC INTERNATIONAL BUILDINGCODE

ID INSIDE DIAMETERINSUL INSULATIONINT INTERIOR

J

K

K KIPS (1000 LB)KO KNOCK-OUTKP KICKPLATEKPD KEYPADKSF KIPS PER SQUARE FOOT

L

L ANGLELAV LAVATORYLG LONGLKB LOCKABLELL LIVE LOADLLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLOC LOCATIONLP LOW POINTLT LIGHTLWC LIGHTWEIGHT CONCRETE

M

MAS MASONRYMAT'L MATERIALMAX MAXIMUMMECH MECHANICALMEMB MEMBRANEMEP MECHANICAL, ELECTRICAL

AND PLUMBINGMFG MANUFACTURERMGO MEDICAL GAS OUTLETMIN MINIMUMMISC MISCELLANEOUSMO MASONRY OPENINGMOB MEDICAL OFFICE BUILDINGMOD BIT MODIFIED BITUMENMOD MODIFIEDMSL MEAN SEA LEVELMTL METAL

N

NA NOT AVAILABLENIC NOT IN CONTRACTNOA NOTICE OF ACCEPTANCE NOM NOMINALNS NEAR SIDENTS NOT TO SCALENWC NORMAL WEIGHT CONCRETE

O

OA OVER ALLOC ON CENTEROD OUTSIDE DIAMETEROD OVERFLOW DRAINOFCI OWNER FURNISHED,

CONTRACTOR INSTALLEDOFOI OWNER FURNISHED, OWNER INSTALLEDOH OPPOSITE HANDOPNG OPENINGOPP OPPOSITEOSF OUTSIDE FACE

P

P LAM PLASTIC LAMINATEPC PRECAST CONCRETEPCF POUNDS PER CUBIC FOOTPCP PORTLAND CEMENT

PLASTERPENT PENTHOUSEPL PROPERTY LINEPL PLATEPLUMB PLUMBINGPLYWD PLYWOODPP PUSH PLATEPOL POLISHEDPORT CEM PORTLAND CEMENTPR PAIRPREFAB PREFABRICATEDPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPT POINTPT PNEUMATIC TUBEPTD PAINTED

R

R RISERRAD RADIUSRAF RUBBERIZED ASPHALT

FLASHINGRAM RUBBERIZED ASPHALT

MEMBRANERAU RUBBERIZED ASPHALT

UNDERLAYMENTRCP REFLECTED CEILING PLANRD ROOF DRAINREBAR REINFORCING BARRECP RECEPTACLEREF REFER OR REFERENCEREINF REINFORCINGRELOC RELOCATE/RELOCATEDREQ'D REQUIREDRFVC RECESSED FIRE VALVE

CABINETRM ROOMRO ROUGH OPENING

SAB SOUND ATTENUATION BLANKET

SBC STANDARD BUILDING CODESCHED SCHEDULESDL SUPERIMPOSED DEAD LOADSECT SECTIONS/H SINGLE HUNGSHWR SHOWERSIM SIMILARSO STRUCTURAL OPENINGSOG SLAB ON GRADESP STAND PIPESPA SPACE, SPACINGSPEC SPECIFICATIONSQ SQUARESS STAINLESS STEELSSF SOLID SURFACESTA STATIONSTC SOUND TRANSMISSION

CLASSSTD STANDARDSTIFF STIFFENERSTIR STIRRUPSTL STEELSTRUC STRUCTURALSYM SYMMETRICALSYS SYSTEM

S

T

T TREAD T&B TOP AND BOTTOMTC TOP OF CURBTEL TELEPHONETEMP TEMPERATURETHK THICKTLT TOILETTO TOP OFTOB TOP OF BEAMTOC TOP OF CONCRETETOF TOP OF FOOTINGTOP TOP OF PARAPETTOS TOP OF SLABTOSTL TOP OF STEELTRSH CH TRASH CHUTETW TOP OF WALLTYP TYPICAL

U

U/C UNDER COUNTER U/G UNDERGROUNDUNO UNLESS NOTED OTHERWISE

VAR VARIES VCT VINYL COMPOSITION TILEVERT VERTICALVEST VESTIBULEVWC VINYL WALL COVERING

V

W/ WITHW/C WHEEL CHAIRW/O WITHOUTW WIDTHWP WATERPROOF(ING)WD WOODWF WIDE FLANGEWL WIND LOADWP WORK POINTWPO WORK POINT - POINT OF

ORIGINWP1 WORK POINT - NUMBEREDWWF WELDED WIRE FABRIC

W

NUMBERING SYSTEM:

A2.10/01

DISCIPLINE:C - CIVILL - LANDSCAPEA - ARCHITECTUREM - MECHANICALE - ELECTRICALP - PLUMBINGS - STRUCTURALK - FOOD SERVICE

SERIES NUMBER

SHEET NUMBER WITHIN SERIES

NUMBER OF PLAN, DETAIL, ETC. ON SHEET

CONCRETE/ PRECAST CONCRETE

SOIL

SAND, EIFS FINISH COAT, OR CEMENT PLASTER

BRICK

CMU

STONE

GLASS MINERAL FIBER SEMI RIGID INSULATION

GLASS MINERAL FIBER BATT INSULATION

MINERAL WOOL SEMI RIGID INSULATION

EXPANDED POLYSTYRENE RIGID INSULATION

EXTRUDED POLYSTYRENE RIGID INSULATION

POLYISOCYANURATE RIGID INSULATION

GYPSUM BOARD

EXTERIOR GYPSUM SHEATHING

EXTERIOR CEMENT BOARD

COATED GLASS MAT WATER RESISTANT GYP BD

PLYWOOD

COVER BOARD

MATERIALS

ROOM NAME

XXXXX

X

X

1

A0.XX

X

A3

A3

ROOM NAME/NUMBER

EXISTING COLUMN CENTERLINE

COLUMN CENTERLINE

ACCESSORY

DEMOLITION NUMBERED NOTES

BUILDING WALL SECTION

ELEVATION

SECTION DETAIL

PLAN, BLOW-UP DETAIL

INTERIOR ELEVATION INDICATOR

DIRECTION INDICATOR

PARTITION TYPE WITH NO SOUND ATTENUATION

PARTITION TYPE WITH SOUND ATTENUATION

CMU WALL

NEW WALL

EXISTING WALL

DEMO WALL

DRAWING SYMBOLS

CEILING SYMBOLS

BUILDING EXPANSION JOINT

GYP BD CEILING

SUPPLY AIR

RETURN AIR

ACCESS PANEL

FLUORESCENT LIGHT

WALL MOUNTED FLUORESCENT FIXTURE

EXIT SIGNS - HATCH INDICATES EXIT TEXT AND ARROW INDICATES DIRECTION

SMOKE DETECTOR

WALL WASHER

PENDANT TYPE LIGHT FIXTURE

WALL MOUNTED LIGHT FIXTURE

DOWNLIGHT

STRIP LIGHT

SPEAKER

MEDICAL EQUIPMENT

CORNER GUARDS

CRASH RAIL

BUMPER RAIL

HAND RAIL

BED LOCATOR

WALL PROTECTION

IV TRACK

CUBICLE CURTAIN TRACK

EDGE OF SLAB

FACE OF BUILDING

PROJECT INFORMATION

PROJECT NAME: CAMP WILLIAMS BUILDING 4101 RENOVATIONADDRESS: 17800 S 1700 W, BLUFFDALE, UT 84065PROPOSED USE: WASHROOMOWNER-CONTACT PERSON: WAYNE SMITH

SD

01

001

+9'-0" CEILING HEIGHT

S

EXHAUST AIR

CR - 3

BG

HR

AAA

3

AAA

3

A0.XX

01

SUSPENDED LIGHT

SUSPENDED FLUORESCENT LIGHT

CHANDELIER

PROJECTOR

A0.XX

01

A0.XX

BL

DUMMY SECTION DETAILA0.XX

LOCATION PLAN

VICINITY MAP

SHEET INDEX

CODE ANALYSIS

APPLICABLE CODES

INTERNATIONAL BUILDING CODE INTERNATIONAL MECHANICAL INTERNATIONAL FUEL GAS CODEINTERNATIONAL PLUMBING CODE INTERNATIONAL FIRE CODE INTERNATIONAL ENERGY CONSERVATION CODE

NATIONAL ELECTRICALCODEUNIFORM CODE FORBUILDING CONSERVATIONADA ACCESSIBILITYGUIDELINESINTERNATIONAL EXISTING BUILDING CODE

2015 2015 20152015

2015 IBC

2015

Year Year

2014

2015 IBC

2015

A. OCCUPANCY AND GROUP: A-4

CHANGE IN USE: YES _______ NO _______ MIXED OCCUPANCY: YES ________ NO ________ SPECIAL USE AND OCCUPANCY (E.G. HIGH RISE, COVERED MALL): _____________________________

B. SEISMIC DESIGN CATEGORY: __________ DESIGN WIND SPEED __________ mph

C. TYPE OF CONSTRUCTION (CIRCLE ONE):

IA

IB

IIA

IIB

IIIA

IIIB

IVHT

VA

VB

D. FIRE RESISTANCE RATING REQUIREMENTS FOR THE THE EXTERIOR WALLS BASED ON THE FIRE SEPARATION DISTANCE (IN HOURS):

NORTH: _______ SOUTH: _______ EAST: ________ WEST: ________

E. MIXED OCCUPANCIES: ________ NONSEPARATED USES: ________

F. SPRINKLERS:

REQUIRED: _______ PROVIDED: ________

TYPE OF SPRINKLER SYSTEM (IBC 903.3.1) ____________________

G. NUMBER OF STORIES: _______ Building Height: ______

H. ACTUAL AREA PER FLOOR (SQUARE FEET): 1,686.19 SF

I. ALLOWABLE AREA (TABLE 506): 6,000 SF

J. AREA MODIFICATIONS:

a)

b) SUM OF THE RATIO CALCULATIONS FOR MIXED OCCUPANCIES:

ACTUAL AREA ALLOWABLE AREA

c) TOTAL ALLOWABLE AREA FOR:

1) ONE STORY: 6,000 SF2) TWO STORY: A (2)_______3) THREE STORY: A (3)______

d) UNLIMITED AREA BUILDING: Yes _______ No ________ Code Section: _________

K. FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS).

EXTERIOR BEARING WALLSINTERIOR BEARING WALLSEXTERIOR NON-BEARINGWALLSSTRUCTURAL FRAMEPARTITIONS - PERMANENTFIRE BARRIERS

FLOORS - CEILING FLOORSROOFS - CEILING ROOFSEXTERIOR DOOR AND WINDOWSHAFT ENCLOSURESFIRE WALLSFIRE PARTITIONSSMOKE PARTITIONS

ELEMENT HOURSASSEMBLY

LISTINGELEMENT HOURS

ASSEMBLYLISTING

L. DESIGN OCCUPANT LOAD: ________________

EXIT WIDTH REQUIRED: ___________ EXIT WIDTH PROVIDED: ___________

M. MINIMUM NUMBER OF REQUIRED PLUMBING FACILITIES:

a) WATER CLOSETS - REQUIRED (M) _____ (F) _____ PROVIDED (M) _____ (F) _____ b) URINALS - REQUIRED _____ PROVIDED ______c) LAVATORIES - REQUIRED (M) ______ (F) ______ Provided (M) ______ (F) ______d) BATH TUBS OR SHOWERS: REQUIRED _______ PROVIDED _______e) DRINKING FOUNTAINS: REQUIRED _______ PROVIDED ________f) SERVICE SINKS: REQUIRED _______ PROVIDED ________

FOOTNOTES:

1) IN CASE OF CONFLICT WITH THE U.S DEPARTMENT OF JUSTICE FEDERAL REGISTERS PARTS ITHROUGH V - ADA GUIDELINES AND SPECIFIC REFERENCE TO THE INTERNATIONAL BUILDING CODE ACCESSIBILITY CHAPTERS, THE MORE RESTRICTICE REQUIREMENT SHALL GOVERN.

2) ADDITIONAL CODE INFORMATION SHALL BE PROVIDED AT THE DISCRETION OF THE BUILDINGOFFICIAL FOR COMPLEX BUILDINGS. INCLUDING, BUT NOT LIMITED TO:

A) HIGH RISE REQUIREMENTS.B) ATRIUMSC) PERFORMANCE BASED CRITERIA.D) MEANS OF EGRESS ANALYSIS.E) FIRE ASSEMBLY LOCATOR SHEETF) EXTERIOR AND INTERIOR ACCESSIBILITY ROUTE.G) FIRE STOPPING, INCLUDING TESTED DESIGN NUMBER.

X

0 0 0 0

NO NO

NO

aa

00

0000

00

0N/A

310

34

32" 80"

1 1 11 11

0.5 9

1 1 12 12

11N/A

1 0

1 2

X

NO

1 13'-5"

N/AN/A

NONE REQ.NONE REQ.

ABLE-BODIED FACILITY NOTICE

THE UTAH NATIONAL GUARD AT CAMP WILLIAMS HAS DESIGNATED THIS BUILDING AS AN ABLE-BODIED FACILITY. THE CAMP HAS DESIGNATED OTHER FACILITIES AT THE CAMP TO ACCOMMODATE INDIVIDUALS WITH INCREASED ACCESSIBILITY REQUIREMENTS ABOVE WHAT IS BEING PROVIDED BY THIS PROJECT.THIS FACILITY IS CONSIDERED AN EMPLOYEE WORK AREA AS OUTLINED IN THE ACCESSIBILITY CODES. DESIGN HAS TAKEN INTO CONSIDERATION THE NON-REQUIRED TURNING SPACES AND ACCESSIBLE CLEARANCES WHENVER POSSIBLE.

X N/A

ISSUED FOR INFORMATION ONLY

ISSUED FOR CONSTRUCTION X

O

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

1:4

2:3

5 P

M

A0.01

PROJECT

INFORMATION

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

SHEET INDEX

Sheet Number Sheet Name 01

/28/2

01

9 -

PE

RM

IT S

ET

02/1

4/2

020

- C

ON

ST

RU

CT

ION

DO

CU

ME

NT

S

ARCHITECTURAL

A0.00 COVER SHEET O O

A0.01 PROJECT INFORMATION O O

AD.01 DEMOLITION PLAN O O

ALS.01 LIFE SAFETY PLAN O O

A2.01 REMODEL PLANS O O

A2.02 METAL ROOFING DETAILS O

A3.00 PARTITION TYPES/DETAIL, GYP BD DETAILS, METAL FAB, WALL PROTECTION O O

A3.01 PARTITION FRAMING DETAILS O O

A3.20 ADAAG/ANSI TOILET LAYOUTS AND STD ACCESSORIES, SHOWER AND TUB DTL O O

A3.30 DOOR, SAFETY GLAZING, LOUVERS & FINISH INFO O O

A3.50 INTERIOR ELEVATIONS AND CABINET DETAILS O O

A5.01 EXTERIOR ELEVATIONS O O

A7.01 EXTERIOR DETAILS O

STRUCTURAL

S0.01 STRUCTURAL NOTES O

S0.02 SCHEDULES O

S1.01 FOOTING, FOUNDATION & ROOF FRAMING PLAN O

S2.01 DETAILS O

S2.02 DETAILS O

S4.01 SCHEMATIC REFERENCE O

MECHANICAL & PLUMBING

M0.00 LEGEND OF MECHANICAL SYMBOLS AND ABBREVIATIONS O O

MD1.01 MECHANICAL AND PLUMBING DEMOLITION PLANS O

M1.01 MECHANICAL PLANS O O

M5.01 MECHANICAL DETAILS AND SCHEDULES O O

P1.01 PLUMBING PLANS O O

P5.01 MECHANICAL DETAILS AND SCHEDULES O O

ELECTRICAL

E0.01 SYMBOLS, SCHEDULES AND NOTES O O

E0.02 SCHEDULES O O

E1.01 ELECTRICAL DEMOLITION PLANS O

E2.01 LIGHTING PLAN O O

E3.01 POWER AND SYSTEMS PLAN O O

NO. DESCRIPTION DATE

Page 3: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

1 2

B

A

63' - 8 3/4"

24

' -

5 1

/4"

GRID LINES REPRESENTS

INTERIOR FACE OF

EXISTING CMU DEMOLISH DOOR AND SIDE LITE DEMOLISH EXTERIOR WALL

DEMOLISH MECHANICAL ROOM WALLS

GRID LINE REPRESENTS

INTERIOR FACE OF

EXISTING CMU

DEMOLISH DOOR AND SIDE LITE

DEMOLISH CONCRETE FLOOR

DEMOLISH DOOR AND FRAME

1 2

B

A

7

7

7 7

7 7

7

7

7 7 7 7 7

7 7 7

7

7

7 7

7

7 7 7 7

7777

8

8

8

8

8

8

7 7

8

DEMO ATTIC ACCESS HATCH

1 2

B

A

REFER TO MECHANICAL DRAWINGS FOR MECHANICAL COMPONENTS

ON ROOF THAT ARE TO BE DEMOLISHED OR ABANDONED

DEMOLISH STANDING SEAM

ROOF SYSTEM

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET

NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAH

DIVISION OF FACILITIES

CONSTRUCTION AND MANAGEMENT

4110 STATE OFFICE BUILDING

SALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARD

CAMP WILLIAMS

17800 S 1700 W

BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

1:1

1:5

4 P

M

AD.01

DEMOLITION PLAN

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

1/4" = 1'-0"01DEMOLITION PLAN

1/4" = 1'-0"02DEMOLITION RCP

1/8" = 1'-0"03DEMOLITION ROOF PLAN

DEMOLITION NOTES

Revision Number Comment

7 DEMOLISH EXISTING LIGHT FIXTURES

8 DEMOLISH EXISTING GYP BOARD CEILING AS REQUIRED FOR INSULATION OF NEW WORK

1. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL UNDERFLOOR PIPING REVISIONS THAT

REQUIRE THE REMOVAL OF PORTIONS OF THE EXISTING SLAB

GENERAL NOTES

NO. DESCRIPTION DATE

Page 4: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

F

353 SF

SHOWER

279 SF

WASH

221 SF

UTILITY SINK

516 SF

TOILET ROOM

78 SF

MECHANICAL

18 SF

HSK

59' - 0"

FEC

28 SF

HSK

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

12:4

9:0

3 P

M

ALS.01

LIFE SAFETY PLAN

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

1/4" = 1'-0"01LIFE SAFETY PLAN - LEVEL 1

OCCUPACY LOAD SCHEDULE

Name Area OL FACTOR PRIMARY USE OL (CALC)

SHOWER 353 SF 50 SF LOCKER ROOM 8

WASH 279 SF 50 SF LOCKER ROOM 6

UTILITY SINK 221 SF 50 SF LOCKER ROOM 5

TOILET ROOM 516 SF 50 SF LOCKER ROOM 11

MECHANICAL 78 SF 300 SF MECHANICAL 1

HSK 18 SF 300 SF STORAGE 1

HSK 28 SF 300 SF STORAGE 1

33

LIFE SAFETY LEGEND

ROOM NAMENAME AND AREA

1 HR FIRE BARRIER

1 HR FIRE/SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE/SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED WALL

SMOKE COMPARTMENT

HORIZONTAL EXIT WALL

OCCUPANCY SEPERATION WALL

FIRE EXTINGUISHER CABINET

FIRE HOSE CABINET

STANDPIPE HOSE CNXN CABINET

EMERGENCY KEY CABINET

EXIT SYMBOL

FEC

FHC

FIRE EXTINGUISHERFE

SHC

EKC

EXIT CORRIDOR

EXIST ENCLOSURE

SUITE

MECHANICAL

ASSEMBLY

STORAGE

EXIT SIGN - HATCHINDICATES EXITTEXT & ARROWINDICATES DIRECTION

XXX' - X"TRAVEL DISTANCE FROM THE MOST REMOTE POINT TO THE CLOSEST

XXX' - X"TRAVEL DISTANCE WITHIN A SMOKE ZONE TO AN

ADJACENT SMOKE ZONE

150 SF

FIRE DEPARTMENT CONNECTION

FDC

NO. DESCRIPTION DATE

Page 5: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

OS

OSOS

OS

OS

OS

OS

OS

A5

.01

/03

A5.01/02

A5

.01

/04

A5.01/01

1 2

B

A

AD

A

TRASH

BENCH

11 TOILET STALLS09 URINAL STALLS12 LAVATORIES04 UTILITY SINKS11 SHOWERS

VE

RIF

Y IN

FIE

LD

24

' - 5

1/4

"

A6

H3

A3

A6

A6

A3

A6

A3

A3

A3A3

A3

A3

A3

A3

A3

N1

VERIFY IN FIELD

63' - 8 3/4"

SHOWER

102

HSK

101

WASH

103

UTILITY SINK

104TOILET

105

MECH

106

FEC

MF08CG-20

CG-20

HOSE BIB

REF. A3.00/05MF08REF. A3.00/05

CG-20

101

BULLNOSE TILE AT ALL OUTSIDE CORNERS, TYP

CG-20

1' -

8"

NEW MECHANICAL UNIT

CT - 02

CT - 02

CT

-02

CT - 02

8' -

6"

TEAK BENCH -BASIS OF DESIGN EARTHLY 18" BY ECO DECORS

FIN

TO

FIN

3' -

0"

TY

P

REFER TO A3.20/01 FOR RECESSED DRAIN CONSTRUCTION

REFER TO A3.20 FOR TYPICAL SHOWER DETAILS

HSK

107

05

A5.01

6' - 1" 11' - 0" 4' - 6"

7' - 8" 12' - 10"

6' - 0" 9' - 4" 11' - 11 1/4"

10

' - 1

0"

5' -

1"

14

' - 8

"

4' - 0" TILE WAINSCOTING ALL AROUND ROOM

3' - 5"

FD

FD

U1

U1

U1

U1

U2

U1

U1

U1

U1

S4 S4 S4 S1

S4 S4 S4 S4 S4

U1

FD FD

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1SH1

SH2

SH2

SH2

SH2SH2

SH2

SH2

SH2

SH2

SH2

107

106

10

4

10

3

FD

FD

A3.50 0102

A3.50 0403

A3.50

07

0506

A3.50

09

08

DOWNSPOUT AND SPLASHBLOCK

7' -

6"

7' -

0"

9' -

0"

3' -

9"

5' - 6"

FD

NEW CONCRETE PAD

FD

FD

FD

W/ MAU MFG

VERIFY MAU SIZE

FOUNDATION

3' - 6" FROM

4' -

6"

W/ M

AU

MF

G

VE

RIF

Y M

AU

SIZ

E

1' -

0"

EQ

EQ

1' -

0"

1' - 6"

(3) BOLLARDS (MF01A) - PAINT SAFETY YELLOW -REFA3.00/06

TYP3"

21' - 11 1/4"

RO

5' - 9 1/2"

FD

FD

A3

A3

A3

A6

2' - 1" 25' - 2"

TYP

6' - 1"

3' -

3"

10' - 11 1/2"

7' -

9 1

/8"

19

' - 9

"

2' -

0"

CG-20

2' -

0"

2' -

0"

2' - 0"

5' -

7"

10' - 0"

2' -

4"

28' - 0 5/8"

RO

7' - 7 1/2"

GRID LINE IS INTERIOR FACE OF EXISTING CMU, TYP

1 2

B

A

EQ EQ

1' -

9 1

/2"

4' -

6"

4' -

6"

1' -

9 1

/2"

1' -

9"

CJ CJ

CJ CJ CJ

AF8' - 0"

SHOWER

102

HSK

101

WASH

103

UTILITY SINK

104

TOILET

105

MECH

106

EQ

EQ

EQ EQ

EQ EQ

EQ EQ

EQ

EQ

EQ EQ

EQ

EQ

MOUNT EMERGENCY LIGHT ALIGNED WITH T.O. WINDOW, TYP

EQ EQ

CENTER OVER DRAIN, TYP

EQ

EQ

EQ EQ

5' - 7 3/4" 5' - 5 3/8"

EQ EQ

EQ EQ

4' - 0 3/8" 3' - 8 3/4" 3' - 11 1/8" 3' - 10"

HSK

107

EQ

EQ

EQ

EQ

EQ EQ

EQ EQ

1' -

0"

EQ EQ

1' -

2"

EQ EQ

8' -

0"

8' -

0"

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

CJ

EQ EQ

EQ

EQ

EQ EQ

1' - 6"

1' - 6"

5/8" GYP BD ON 3/4" FURRING STRIPS AT BOTTOM OF ROOF TRUSS

CEILING SYMBOL LEGEND

GYPSUM BOARD CEILING

SUPPLY AIR

RETURN AIR

EXHAUST AIR

ACCESS PANEL

RECESSED LIGHT

SUSPENDED LIGHT

SUSPENDED STRIP LIGHT

WALL MOUNTEDFIXTURE

CONTROL JOINTS

CHANDELIER

EXIT SIGN - HATCHINDICATES EXIT TEXT& ARROW INDICATES DIRECTION

HEAT DETECTORHD

FIRE ALARM / STROBEFA

SPEAKERS

WALL WASHER

PENDANT TYPE LIGHTFIXTURE

WALL MOUNTEDLIGHT FIXTURE

DOWNLIGHT

STRIP LIGHT

1. ALL CEILINGS SHALL BE 8' - 0" ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. (COORDINATE WITH OWNER-FURNISHED VENDOR DRAWINGS AND EQUIPMENT.

2. IN THE CASE OF MINOR DISCREPANCIES BETWEEN MEP AND ARCHITECTURAL DOCUMENTS IN THE LOCATION OF CEILING MOUNTED COMPONENTS, THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN. IN THE CASE OF MAJOR DISCREPANCIES, THE ARCHITECT SHALL BE NOTIFIED AS SOON AS THE DISCREPANCY IS DISCOVERED PRIOR TO PROCEEDING WITH THE WORK.

3. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS REQUIRED OF INDICATED.

4. LIGHTS, DIFFUSERS, EXIT SIGNS, SMOKE DETECTORS, SPEAKERS, STROBES AND MISCELLANEOUS DEVICES SHALL BE CENTERED IN THE CEILING TILE IN WHICH THEY OCCUR, UNLESS NOTED OTHERWISE.

5. ALL CORRIDOR SPRINKLER HEADS SHALL BE ALIGNED IN THE SAME LOCATION PARALLEL TO THE WALL WITHIN EACH SPECIFIC CEILING CONSTRUCTION. ARCHITECTURALLY SIGNIFICANT SPRINKLER HEAD LOCATIONS MAY BE SHOWN ON REFLECTED CEILING PLAN FOR DESIGN INTENT ONLY.

6. ACCESS DOOR LOCATIONS IN GYPSUM BOARD CEILINGS ARE INDICATED ON RCP'S ONLY WHERE ARCHITECTURALLY SIGNIFICANT. REFERENCE SPECIFICATIONS AND MEP DRAWINGS FOR OTHER ACCESS DOOR LOCATIONS

7. EXIT SIGNS ARE SHOWN ON REFLECTED CEILING PLAN ONLY WHERE LOCATION IS ARCHITECTURAL SIGNIFICANT.

8. DIMENSIONS AT CUBICLE CURTAIN TRACKS ARE TO CENTER OF TRACK, TYP.

9. ALL CUBICLE CURTAIN TRACKS MUST CLEAR DOOR SWINGS BY 3' MINIMUM. 10.

10. REFERENCE A2.01 FOR CEILING SYMBOL LEGEND.11. REFERENCE A3.00 FOR CONTROL JOINT DETAILS.12. REFERENCE A3.00 FOR METAL FABRICATION DETAILS.

GENERAL NOTES - REFLECTED CEILING PLAN

A5

.01

/03

A5.01/02

A5

.01

/04

A5.01/01

1 2

B

A

NEW STANDING SEAM METAL ROOF

RIDGE VENT

SL

OP

E 5

" P

ER

FT

SL

OP

E 5

" P

ER

FT

GUTTER

GUTTER

DOWNSPOUT AND SPLASHBLOCK, TYP AT EA END OF GUTTER

02

A2.02

03

A2.02

03

A2.02

02

A2.0204

A2.02

05

A2.02

PLUMBING VENT

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

1:1

1:5

1 P

M

A2.01

REMODEL PLANS

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

1/4" = 1'-0"01REMODEL PLAN

1/4" = 1'-0"02REFLECTED CEILING PLAN

1. DIMENTIONS ARE TO FACE OF DRYWALL OR FINISH, FACE OF MASONRY UNLESS OTHERWISE NOTED

2. REFER TO SHEET A3.00 FOR PARTITION TYPES/DETAIL, GYP BD DETAILS, METAL FAB, LOCKER WALL PROTECTION

3. REFER TO SHEET A3.20 FOR ADAAG/ANSI TOILET LAYOUTS AND STD SCCESSORIES, SHOWER AND TUB DTL

4. REFER TO SHEET A3.30 FOR DOOR & FINISH INFO5. REFER TO SHEET A3.50 FOR INTERIOR ELEVATIONS DETAIL6. REFER TO SHEET A5.01 FOR EXTERIOR ELEVATIONS7. REFER TO AD.01 FOR DEMOLITION PLANS

GENERAL NOTES

1/8" = 1'-0"03TO WALL FRAMING

NO. DESCRIPTION DATE

Page 6: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

PLYWOOD

ROOFING UNDERLAYMENT

METAL ROOF

SLIP SHEET

ROOF TRUSS AT GABLE END

MTL FLASHING

2X8 WOOD FASCIA

ROOFING UNDERLAYMENT

METAL ROOFING

SLIP SHEET

1' - 6"

METAL PANEL SOFFIT

STRUCTURAL WALL SHEATHING

FACE OF EXTERIOR FINISH SYSTEM

BACKWRAP MESH THEN OVERLAP 2 1/2" MIN - TYPICAL AT SYSTEM RETURNS

COLOR COORDINATED PRIMER/COATING AT SYSTEM RETURNS

SEALANT AND BACKER ROD

2X4 OUTRIGGERS

ROOF SHEATHING3/4"

GUTTER

VENTED SOFFIT (MIN 24 SQ INCHES PER LINEAL FT OF FREE VENTING AREA - 6 SQ INCHES PER LINEAL FT AT EACH EAVE AND 12 SQ INCHES PER LINEAL FT AT THE RIDGE)

2 x 8 FASCIA

GUTTER STRAP

SHEET METAL EAVE FLASHING

FIELD NOTCH 1" MIN AND HEM UNDER

RUBBERIZED ASPHALT UNDERLAYMENT

SLIP SHEET

METAL ROOFING

5"

AIR

GA

P1" M

IN

VENT CHUTE AND HEEL BAFFLE.

1' -

0"

HE

EL

FO

R R

OO

F IN

SU

LA

TIO

N

SEALANT AND BACKER ROD EA SIDE

R-38 BATT INSULATION

EXTERIOR INSULATION AND FINISH SYSTEM

3/4"

1' - 6"

NOTCH UPPER CORNERS OF BLOCKING FOR AIR FLOW

06

A2.02

5"

ROOFING UNDERLAYMENT

FASTENER INTO ROOF TRUSS

SLIP SHEET

"Z" CLOSURE

METAL ROOFING

VENTED SHEET METAL RIDGE CAP - COLOR TO MATCH METAL ROOFING

MIN

2"

MIN1 1/2ʺ

MIN

1 1/2ʺ

CURROGATED POLYETHELENE RIDGE VENT

3"

MIN

6"

MIN

6"

BAFFLE

VENT CHUTE

1"

1"

R-38 BATT INSULATION

RUBBERIZED ASPHALT UNDERLAYMENT

6"

6"

SLIP SHEET

METAL ROOFING

SOLDERED SEAM

SHEET METAL FLASHING

FLASHING CAP

VENT CHUTE

3 1/2ʺ

3 1

/2ʺ

3 1

/2ʺ

3 1/2ʺ

DOUBLE TOP PLATE

ROOF TRUSS

ROOF SHEATHING

NOTCH EACH UPPER CORNER OF THE BLOCKING BETWEEN TRUSSES TO PROVIDE MIN 6 SQ INCHES CLEAR AREA AT EACH NOTCH FOR VENTING

BETWEEN TRUSS BLOCKING - REF STRUCTURAL

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

12:4

8:4

4 P

M

A2.02

METAL ROOFING

DETAILS

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

3" = 1'-0"01METAL ROOFING

3" = 1'-0"02GABLE END EDGE FLASHING

3" = 1'-0"03

DOWNSLOPE

PERIMETER WITH GUTTER

3" = 1'-0"04VENTING RIDGE CAP

3" = 1'-0"05PLUMBING VENT FLASHING

NO. DESCRIPTION DATE

1 1/2" = 1'-0"06TRUSS BLOCKING AIR FLOW DETAIL

Page 7: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

REFER TO PARTITION HEAD DETAILS

SEALANT

MTL RUNNER

SEALANT

MTL RUNNER

5/8" GYP BD EACH SIDE

LINE OF STRUCTURE

LINE OF CEILING

LINE OF STRUCTURE

FLOOR PLAN DESIGNATION NO SOUND ATTENUATION

FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION

STUD SIZE

PART WIDTH

FIRE RATING

UL LISTING WITH SOUND

STC:NO SOUND

REMARKS

3 5/8" 4 7/8"NON-

RATEDN/A 49

W/3" SAB

40

2 1/2"

6"

3 5/8"

2 1/2"

6"

3 5/8"

2 1/2"

6"

3 5/8"

3 3/4"

7 1/4"

4 7/8"

3 3/4"

4 7/8"

7 1/4"

3 3/4"

7 1/4"

4 7/8"

NON-RATED

NON-RATED

SMOKE RESIST

SMOKE RESIST

SMOKE RESIST

ONE HOUR

ONE HOUR

ONE HOUR

ONE HOUR/ SMOKE RESIST

U465 49W/3" SAB

40

2 1/2" 3 3/4"

ONE HOUR/ SMOKE RESIST

6" 7 1/4"

ONE HOUR/ SMOKE RESIST

U465 49W/3" SAB

40

N/A

N/A

N/A

N/A

N/A

U465

U419

U465

49W/3" SAB

40

49W/3" SAB

40

49W/3" SAB

40

49W/3" SAB

40

49W/3" SAB

40

49W/3" SAB

40

49W/1 1/2" SAB

N/A

49W/3" SAB

40

REFER TO PARTITION HEAD DETAILS

TYPE "E"

3 5/8"

REF FLOOR PLAN

NON-RATED

N/A 52W/3 1/2" SAB

N/A

3 5/8"ONE

HOURU420 52

W/3 1/2" SAB

N/AREF FLOOR PLAN

LINE OF STRUCTURE

LINE OF CEILING

LINE OF STRUCTURE

SEALANT

MTL RUNNER

SEALANT

MTL RUNNER

5/8" GYP BD EACH SIDE

3 5/8" STUD CROSS BRACING

REFER TO PARTITION HEAD DETAILS

TYPE "H"

MTL RUNNER

SEALANT

MTL RUNNER

5/8" GYP BD

3 5/8" 4 1/4"NON-

RATEDN/A

2 1/2"

6"

3 1/8"

6 5/8"

NON-RATED

NON-RATED

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

LINE OF STRUCTURE

LINE OF STRUCTURE

REFER TO PARTITION HEAD DETAILS

MTL RUNNER

SEALANT

MTL RUNNER

5/8" GYP BD

3 5/8" 4 1/4"NON-

RATEDN/A

2 1/2"

6"

3 1/8"

6 5/8"

NON-RATED

NON-RATED

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

LINE OF STRUCTURE

LINE OF STRUCTURE

LINE OF CEILING

TYPE "K"

1 5/8" 3"NON-

RATEDN/A

2 1/2"

3 5/8"

4"

5"

NON-RATED

NON-RATED

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

SEALANT

MTL RUNNER

5/8" GYP BD

LINE OF STRUCTURE

LINE OF STRUCTURE

BRACE EACH STUD AT 4'-0" OC VERTICALLY

LINE OF STRUCTURE OR OTHER CONSTRUCTION PROVIDING BACK-UP FOR STUD BRACING

TYPE "M"

1 5/8" 3"NON-

RATEDN/A

2 1/2"

3 5/8"

4"

5"

NON-RATED

NON-RATED

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

SEALANT

MTL RUNNER

5/8" GYP BD

LINE OF STRUCTURE

LINE OF CEILING

BRACE EACH STUD AT 4'-0" OC VERTICALLY

LINE OF STRUCTURE OR OTHER WALL CONSTRUCTION PROVIDING BACK-UP FOR STUD BRACING

TYPE "B"

A3 A3

A2 A2

A6 A6

A3

A2 A2

A6 A6

A3

A2

A6 A6

A3

A2

A6 A6

E3 E3

E3 E3

H3

H2

H6

J3

J2

J6

K1

K2

K3

M1

M2

M3

REFER TO SCHEDULE BELOW FOR PARTITION WIDTH 3" MIN

FLOOR PLAN DESIGNATION NO SOUND ATTENUATION

FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION

STUD SIZE

PART WIDTH

FIRE RATING

UL LISTING WITH SOUND

STC:NO SOUND

REMARKS

FLOOR PLAN DESIGNATION NO SOUND ATTENUATION

FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION

STUD SIZE

PART WIDTH

FIRE RATING

UL LISTING

SOUND TRANS CLASS REMARKS

FLOOR PLAN DESIGNATION NO SOUND ATTENUATION

FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION

STUD SIZE

PART WIDTH

FIRE RATING

UL LISTING REMARKS

FLOOR PLAN DESIGNATION NO SOUND ATTENUATION

FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION

STUD SIZE

PART WIDTH

FIRE RATING

UL LISTING REMARKS

FLOOR PLAN DESIGNATION NO SOUND ATTENUATION

FLOOR PLAN DESIGNATION WITH SOUND ATTENUATION

STUD SIZE

PART WIDTH

FIRE RATING

UL LISTING REMARKS

LINE OF CEILING

LINE OF CEILING

TYPE "A"

PARTITION WIDTH

REFER TO SCHEDULEBELOW FOR

FLOOR PLANREFER TO

3"

PARTITION WIDTH

REFER TO SCHEDULEBELOW FOR

PARTITION WIDTH

REFER TO SCHEDULEBELOW FOR

3"

PARTITION WIDTH 3" MIN

REFER TO SCHEDULEBELOW FOR

3"

SOUND TRANS CLASS

SOUND TRANS CLASS

SOUND TRANS CLASS

NOTES

PARTITION TYPE INCLUDED IN SCOPE OF WORK

PARTITION TYPE NOT INCLUDED IN SCOPE OF WORK

1. PARTITIONS ARE DISTINGUISHED ON FLOOR PLANS BY SYMBOL DESIGNATION, GRAPHIC DESIGNATION OR A COMBINATION OF BOTH DESIGNATIONS.

2. THERE ARE TWO TYPES OF SYMBOL DESIGNATIONS, ONE FOR PARTITIONS NOT REQUIRING SOUND ATTENUATION AND ANOTHER FOR PARTITIONS WHICH REQUIRE SOUND ATTENUATION. REFER TO PARTITION MATRICES FOR SOUND ATTENUATION BLANKET (SAB) MINIMUM THICKNESS FOR STC INDICATED.

3. THERE ARE TWO SYMBOL DESIGNATION SYSTEMS USED. THE FIRST SYSTEM CONSISTS OF TWO AND THREE CHARACTERS, THE FIRST CHARACTER IS A LETTER INDICATING THE PARTITION TYPE. THE SECOND CHARACTER IS NUMERIC INDICATING THE STUD OR CMU WIDTH. REFER TO LEGEND BELOW. THIS SYSTEM IS USED TO DEFINE WALL TYPES: A, B, C, D, E, F, H, J, K, M, R

THE # CHARACTER BELOW THE LINE INDICATES THE HEIGHT OF THE SPECIFIC WALL COMPONENT. THE HEIGHT OF A SPECIFIC WALL COMPONENT. REFER TO THE LEGEND BELOW. THIS SYSTEM IS USED TO DEFINE WALL TYPES: RA THRU RR

4. IF NO SYMBOL DESIGNATION IS PROVIDED, THE STUD SIZE WILL BE 3 5/8".

5. THE GRAPHIC DESIGNATION IS INCORPORATED FOR PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT. REFER TO NOTE 18.

6. "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY.

7. ALL DIMENSIONS ARE FROM FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD. REFER TO PARTITION MATRICES FOR PARTITION WIDTH DIMENSIONS UNLESS INDICATED TO BE SHOWN ON PLAN.

8. SEALANT:1. FIRE RESISTANCE RATED PARTITIONS SHALL USE RATED FIRE/SMOKE FIRE RESISTANT FILL

MATERIAL IN CONJUNCTION WITH AN APPROPRIATE RATED FIRE/SMOKE FIRE STOPPING SYSTEM.2. NON-RATED PARTITIONS AND NON-RATED SMOKE RESISTANT PARTITIONS SHALL USE ACOUSTICAL SEALANT.

9. INSULATION: - HEAD CONDITIONS AT FLOOR/ROOF DECK1. FIRE RESISTANCE RATED PARTITIONS SHALL USE MINERAL WOOL INSULATION.2. NON-RATED PARTITIONS REQUIRING SOUND ATTENUATION SHALL USE SOUND ATTENUATION

BLANKETS (SAB).3. PROVIDE FULL THICKNESS INSULATION INSIDE ALL STUD BOX BEAMS AND HEADERS WHICH OCCUR

IN WALLS WITH SOUND ATTENUATION.

10. REFER TO SPECIFICATIONS FOR MINIMUM STUD THICKNESS, MAXIMUM SPACING AND ALLOWABLE LIMITING HEIGHTS DEFLECTION CRITERIA FOR GYPSUM BOARD ASSEMBLIES.

11. FOR PARTITIONS INDICATED TO RECEIVE SOUND ATTENUATION BLANKETS (SAB), EXTEND SAB TO FULL HEIGHT OF PARTITION UNLESS OTHERWISE INDICATED. FLOOR TRACK TO BE SET IN A CONT BED OF SEALANT.

12. FIRE RESISTANT AND FIRE RESISTANT SMOKE BARRIER RATINGS ARE TO SURROUND ALL OPENINGS IN RATED PARTITIONS.

NUMERIC CHARACTER

STUD WIDTH

CMU WIDTH

12346812

1 5/8"2 1/2"3 5/8"

4"6"

3 5/8"5 5/8"7 5/8"

11 5/8"

13. SMOKE RESISTANT, FIRE RESISTANT, AND FIRE RESISTANT SMOKE BARRIER PARTITIONS SHALL EXTEND AND SEAL TO INSIDE FACE OF EXTERIOR SHEATHING, INCLUDING EXTENSIONS THROUGH SOFFITS.

14. EACH PARTITION SHOWN ON THE DRAWINGS TO HAVE A FIRE AND SMOKE RESISTANT RATING SHALL BE IDENTIFIED AS SUCH WITH A LABEL ABOVE THE CEILING ON EACH SEGMENT OF THE WALL AND 6' - 0" OC MAX EACH SIDE.

15. REFER TO TOILET ACCESSORIES SHEET AND CASEWORK SHEET FOR MOUNTING DETAIL INFORMATION.

16. REFER TO THE METAL FABRICATIONS DETAILS FOR MF REFERENCES IN PARTITIONS SECTION.

17. REFER TO STRUCTURAL DRAWINGS FOR REINFORCING INFORMATION.

18. GRAPHIC DESIGNATION

19. DO NOT APPLY BULLNOSE BLOCK AT CORNER GUARD LOCATIONS.

20. MASONRY REINFORCEMENT: REFERENCE STRUCTURAL DRAWINGS.

21. HW (HEAD OF WALL) DETAILS DO NOT ALTER PARTITION TYPES NOTED ON PLANS.

4 HR FIRE BARRIER3 HR FIRE BARRIER2 HR SMOKE BARRIER2 HR FIRE BARRIER2 HR FIRE BARRIER/SHAFT WALL1 HR SMOKE BARRIER1 HR FIRE BARRIER1 HR FIRE BARRIER/SHAFT WALLSMOKE PARTITION (NON RATED)

PRIORITY

1 HIGHEST2

3

4

5 LOWEST

NOTE:

1. NOT ALL PARTITION TYPES SHOWN ON THIS SHEET ARE USED ON THIS PROJECT.

2. THE SHADED PORTIONS OF A PARTITION TYPE ARE NOT INCLUDED IN THE SCOPE OF THE WORK.

3. THE UN-SHADED PORTIONS OF ALL PARTITION TYPES ARE INTENDED TO BE IN THE SCOPE OF THE WORK.

HATCHING:

NUMERIC CHARACTER

CMU/BRICK HEIGHT

12345

9' - 4"10' - 8"12' - 8"18' - 8"14' - 0"

SYMBOL DESIGNATIONS(NO SOUND ATTENUATION)

SYMBOL DESIGNATION(WITH SOUND ATTENUATION)

X# X#XXXX# XXXX

#

A3

A3

A3

U419 49W/1 1/2" SAB

N/A

MISCELLANEOUS SPECIALTIES

AND EQUIPMENT

MOUNTING DETAIL -REFER TO SHEET A3.01

FINISH FLOOR

DRAWING DESIGNATION

4' -

0"

B

FEC SURFACE MOUNTED FIRE EXTINGUISHER CABINET

NON-RATED OR SMOKE RESISTANT

CONT 22 GA MIN 3" DEEP LEG DEFLECTION TRACK ATTACH TO DECK AT 12" OC MAXDO NOT ATTACH GYP BD

OR STUDS TO DEFLECTION TRACK IN THIS AREA

SEALANT

CONT 2" WIDE X 22 GA MTL STRAP FOR TOP ATTACHMENT OF STUDS

1"

3/4

"

4"

3/4

"

3/4

"

1. REFER TO SPECIFICATIONS FOR HEAD OF WALL SLOTTED TRACK OPTIONS FOR METAL STUD WALLS. CONT 2" WIDE X 22 GA METAL STRAP CAN BE DELETED IF OPTIONAL SLOTTED TRACKS ARE SELECTED.

HEAD OF WALL GENERAL NOTES

PARTITION HEAD DETAILS

PARTITION

SOUND ATTENUATION BLANKET COMPRESSED TO FILL OPENING AT SOUND RATED PARTITION

L-BEADSEALANT AND BACKER ROD

LINE OF PARTITION

1/4”

SEALANT

"LC" - BEAD

PARTITION

24'-0" - 30'-0" MAX

CONTROL JOINT

GYP BOARD SUSPENDED CEILING SYSTEM

24'-0" - 30'-0" MAX

3" UNO

SANDWICH PLATE BETWEEN TWO 18 GA MTL STUDS - PROVIDE 4 EA 3/8" DIA THRU BOLTS AT EACH END OF PLATE

CONT 3 1/4" X 3/8" STEEL PLATE. COORDINATE PROFILE OF PLATE WITH LAVATORY. DASHED LINE INDICATES LOCATION OF BENT PLATE AND PLYWOOD BACKING AT ANGLED CONDITIONS

END WALL

PLAN

NOTE: FINISH AFTER FABRICATION: SHOP PRIMER PAINT

SEALANT

NOTE:PAINT ALL MISC EXPOSED STRUCTURAL STEEL FLAT BLACK.

SECTION

CONT 3 1/4" X 3/8" STL PLATE WELDED TO STL TUBE - FASTEN 3/4" EXT PLYWOOD TO PLATE WITH CSK SELF TAPPING SCREWS AT 12" OC. EXTEND PLATE INTO END WALL PER MF07 DETAIL

TO STRUCTURE ABOVE IF APPLICABLE

NOTE: FINISH AFTER FABRICATION: SHOP PRIMER PAINT

PLAN 29”

5"

COORDINATE LOCATION OF COUNTER SUPPORTS WITH BOWL LOCATIONS

TYP - REF TO PLAN

2' - 0"

PLAN3" = 1' - 0"

3" X 2" X 3/16" HORIZ STL TUBE ABOVE

2" X 2" X 3/16" STL TUBE POST WELDED TO BASE PLATE @ 4' OC

4" X 5" X 3/8" STL BASE PLATE WITH FOUR 1/2" DIA EXP ANCHORS WITH 2 1/4" MIN EMBEDMENT

3/4" 3/4"

4"

3/4

"3

/4"

5"

3" X 2" X 3/16" STL TUBE POST WELDED TO VERTICAL STL TUBE 3 1/2"

3 1

/2"

CORNER GUARD SCHEDULE

CG - 20

CG -21

- 48" HEIGHT

-FULL HEIGHT

SURFACE MOUNTED -NOT FIRE RATED

STAINLESS STEEL

4"

6"

3' -

0"

1' - 6" DIA

NOTE: FINISH AFTER FABRICATION: HOT-DIP GALVANIZE

3/4" (TYP)

SEALANT, BACKER ROD, AND EXPANSION JOINT FILLER

LINE OF PAVING

CONC FOOTING

TWO #5 X 1' - 0" STL BARS THRU PIPE

6" DIA SCHEDULE 80 STEEL PIPE FILLED WITH CONC 4

' -

0"

2'

- 8

"

3/4" (TYP)

GALV METAL POST CAP OVER END OF PIPE, WELDED TO GALV STL PIPE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

12:4

8:4

7 P

M

A3.00

PARTITION

TYPES/DETAIL, GYP BD

DETAILS, METAL FAB,

WALL PROTECTION

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

3" = 1'-0"01

CONTROL JOINT AT

PARTITION INTERSECTION

CHANGE IN CONSTRUCTION

3" = 1'-0"02CONTROL JOINT AT PARTITION

NON-EXPOSED EDGE

3" = 1'-0"03CONTROL JOINT FOR

GYPSUM BOARD CEILING

3" = 1'-0"04MF07 - LAVATORY COUNTER SUPPORT

SPAN LESS THAN 10' - 0"

1 1/2" = 1'-0"05MF08 - LAVATORY COUNTER SUPPORT

SPAN 10' - 0" TO 16' - 0"

1/2" = 1'-0"06 MF01A - NON-REMOVABLE PIPE BOLLARD

NO. DESCRIPTION DATE

Page 8: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

DOUBLE 20 GA 3 5/8" OR 6" MTL STUDS

CLIP ANGLE - 20 GA X 1 1/2" X 1 1/2" X 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE

22 GA MTL TRACK

CLIP ANGLE - 20 GA X 1 1/2" X 1 1/2" X 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE

22 GA MIN MTL TRACK

CLIP ANGLE - 20 GA X 1 1/2" X 1 1/2" X 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS

22 GA MIN MTL TRACK

CLIP ANGLE - 20 GA X 1 1/2" X 1 1/2" X 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS

22 GA MIN MTL TRACK

CLIP ANGLE - 20 GA X 1 1/2" X 1 1/2" X 3" FOR 3 5/8" STUDS AND 5" FOR 6" STUDS

22 GA MIN MTL TRACK AT FLOOR

2 1/2" X 2 1/2" 20 GA MTL STRAP AT 2'-0" OC WITH 4 SCREWS (2 INTO EACH STUD EA SIDE)

20 GA MIN MTL TRACK AT FLOOR

DOUBLE 20 GA MTL STUDS

MIN 20 GA MTL STUDS FACING OPPOSITE DIRECTIONS TO ALLOW MOUNTING PLATE ATTACHMENT (16 GA AT SHOWER SEATS AND ADULT CHANGING STATIONS)

14 GA STL RUNNER TRACK-CLIP FLANGES AND FOLD WEB TO FORM ATTACHMENT FLANGE

RE

FE

R T

YP

ICA

L

MO

UN

TIN

G

HE

IGH

TS

8" MIN DEEPER IF REQUIRED

TYPE CTYPE BTYPE A

RE

FE

R T

YP

ICA

L

MO

UN

TIN

G

HE

IGH

TS

CONT 20 GA 4" WIDE MTL BACK-UP PLATE

HSS 4x2x3/16 W/ 1/8" THICK END PLATES (MIN 8- #12 TEK SCREWS)

RE

FE

R T

YP

ICA

L

MO

UN

TIN

G

HE

IGH

TS

TYPE D

MIN 18 GA MTL DOUBLE STUDS AT 16" OC TO ALLOW MOUNTING PLATE ATTACHMENT

BARIATRIC GRAB BAR

RE

FE

R T

YP

ICA

L

MO

UN

TIN

G

HE

IGH

TS

CONT 18 GA 6" TALL - 8" ONLY REQUIRED BY FHA FOR GRAB BARS

2"

4"

2"

05 05

02

01

03

01

04

DOUBLE STUDS (FULL HEIGHT)

DOUBLE STUDS (FULL HEIGHT)

DOUBLE STUDS (FULL HEIGHT)

MOUNTING DETAIL

B8' - 6" MAX4' - 6" MAX

STONE VENEER WALLS

16 GA STUDS AT 4' - 6" MAX 8' - 6" MAX

DOOR OPENING DOUBLE DOOR OPENING

BELOW CEILING OPENING

LARGE BELOW CEILING

OPENING

PROVIDE DIAGONAL BRACING OF TOP TRACK AT 48" OC MAX BETWEEN FULL HEIGHT STUDS

05

02

DOOR OPENING05

02

DOOR OPENING05

01

DOUBLE DOOR OPENING

03

BELOW CEILING OPENING

01

LARGE BELOW CEILING

OPENING

05

03

ABOVE CEILING

OPENING

LARGE ABOVE CEILING

OPENING

04

01

01

01

OPENING ABOVE CEILING WHICH INTERRUPTS

LOWER OPENINGS JAMB STUDS

MOUNTING DETAIL B

DOUBLE STUDSDOUBLE STUDS

DOUBLE STUDS DOUBLE STUDS

DOUBLE STUDS

STONE VENEER WALLS

16 GA STUDS AT 20 GA STUDS AT

WALL MOUNTED ARCHITECTURAL

CABINETS/MILLWORK /ATTACHED SHELVING

4' - 6" MAX 8' - 6" MAX 4' - 6" MAX4' - 6" MAX 8' - 6" MAX

STUDS ARE TO BE 20 GAGE

IF GREATER THAN 8' - 6" ALL

8' - 6" MAX 8' - 6" MAX

4' - 6" MAX

22 GA MIN BOTTOM TRACK (TYP)

FLOOR LINE

22 GA MIN MTL TOP TRACK (TYP UNO)

CEILING LINE

UNDERSIDE OF SLAB, FLOOR OR ROOF DECK

2" WIDE 22 GA MIN METAL STRAP

1. ALL STUDS ARE SPACED 16" OC MAXIMUM.

2. ALL STUDS SHALL BE "C" STUDS WITH 1/4" FLANGE MINIMUM.

3. DENOTES SHELVING OR CABINETRY.

4. DENOTES STONE.

5. IN NO CASE SHALL DOUBLE STUDS AT SIDES OF OPENING BE CUT FOR DUCTWORK OR OTHER MECHANICAL SYSTEMS.

6. AT LEAD LINED PARTITIONS STUDS SHOULD BE 20 GA.

7. DO NOT CUT MORE THAN ONE STUD WEB TO ALLOW FOR HORIZONTAL PIPING PATH. PROVIDE STRAP AT WEB ABOVE AND BELOW PIPE IN ORDER TO RESTORE STUD INTEGRITY. STRAP GAUGE TO MATCH STUD GAUGE MIN

ACCESSORY/EQUIPMENT MOUNTING DETAILS PARTITION FRAMING DETAILS

04

TYPICAL INTERIOR PARTITION FRAMING

AND ADULT CHANGING STATIONS

16 GA STUDS AT 12" OCAT SHOWER SEATS

NOTES

TYPICAL LEAD LINED DOOR FRAMING DETAILS

MINIMUM STUD SIZING FOR SEISMIC CATEGORY D AND ABOVE IS 20 GA

20 GA MIN MTL TRACK AT FLOOR

DOUBLE 20 GA MTL STUDS AT BOTH JAMBS

2 1/2" X 2 1/2" 18 GA MTL STRAP AT 2'-0" OC WITH 4 SCREWS (2 INTO EACH STUD EA SIDE)

FRAME ANCHORS

3"

18 GA "KING" STUD WITH 3" FLANGES

3" = 1'-0"01

DOUBLE DOOR/LARGE

OPENING HEADER3" = 1'-0"02

DOOR

OPENING HEADER3" = 1'-0"03OPENING HEADER

3" = 1'-0"04

LARGE

OPENING JAMB STUDS3" = 1'-0"05B

OPTION 2

DOOR OPENING

JAMB STUDS3" = 1'-0"05A

OPTION 1

DOOR OPENING

JAMB STUDS

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

12:4

8:4

8 P

M

A3.01

PARTITION FRAMING

DETAILS

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

NO. DESCRIPTION DATE

Page 9: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

REF PLANTOP OF DRAIN

A3.21

02

A3

.21

02

A3

.21

02

A3.21

01

REF PLANTOP OF DRAIN

NOTE: LOCATE FLUSH ACTIVATION ON WIDE SIDE AT ALL TOILETS - LOCATE FLUSH VALVE BENEATH ADJACENT GRAB BARS.

STANDARD LAYOUTS - ADAAG/ANSI SCALE: 1/4" = 1' - 0"

STANDARD COMPARTMENTPLAN DESIGNATION S4

S4B9

OF

WE

T W

AL

L

5' -

6"

TO

FIN

ISH

INSIDE FACE

3' - 0" INSIDEFACE TO

STANDARD URINALPLAN DESIGNATION U1PLAN DESIGNATION U2 @ ACCESSIBLE

30"x48" CLEAR FLOOR SPACE

U1

U2 HC

2' -

0"

2' -

0"

INSIDE FACE

3'-0" INSIDEFACE TO

STANDARD

ACCESSIBLE LAVATORYPLAN DESIGNATION L1

AC

CE

SS

IBLE

LA

V

4' -

0"

3' -

2"

MA

X A

T

FINISH FLOOR

LAV COUNTER

MIRROR

MF07/MF08 LAV SUPPORT

INSULATE PIPING

SE

CT

1' - 9" 2' - 8"UNO

1' - 9"

2' - 8"

UNO

1' - 9"

2' -

0"

L1

30" X 48" CLEAR FLOOR SPACE

MF07 / MF08 LAV SUPPORT

ACCESSIBLE TRANSFER

TYPE SHOWER COMPARTMENTPLAN DESIGNATION SH1

SH1

36" X 48" CLEAR FLOOR SPACE

SE

AT

WA

LL

N1

E7

ELEVATIONPLAN

1' - 0"

CO

NT

RO

L

WA

LL

FIN TO FIN

3' - 0"

E7

FLEXIBLE SHOWER SPRAY HOSE -60" LONG MIN

CONTROL AREA

EQ EQEQ EQ

EL

EV

TO

CL

2' -

10

"

2' -

3"

MAX

2' - 1"

MA

X T

O R

IM

2' -

10

"

FIN

TO

FIN

3' -

0"

E15E15

V1

NOTE:COORDINATE LAVATORY MF08 SUPPORTS WITH BOWL LOCATIONS.

OPENING

26"CLEAR

2' -

9"

CL

4"

4' -

0"

1' - 3"

TOILET ACCESSORY MOUNTING DIAGRAM SCALE: 1/4" = 1'-0"

NOTE:

1. ACCESSORIES LISTED MAY HAVE GAPS IN ALPHABETICAL LISTING.

2. ACCESSORIES CAN APPEAR ON FLOOR PLANS OR INTERIOR ELEVATIONS.

FINISH FLOOR

TOILET ACCESSORY TYPE

MOUNTING DETAIL - REFER TO SHEET A3.03

DRAWING DESIGNATION

FINISH FACE OF WET WALL

TOILET TISSUE DISPENSER

A

B9 TWIN JUMBO -ROLL

FINISH FLOOR

TOILET ACCESSORY TYPE

MOUNTING DETAIL - REFER TO SHEET A3.03

DRAWING DESIGNATION

SHOWER CURTAIN ROD, HOOKS & CURTAIN

A

L1 ROD

L2 SHOWER CURTAIN TRACK -SECURITY

SOAP DISH

A

M1 SURFACE MOUNTED

MOP AND BROOM HOLDER WITH SHELF

A

P1 SURFACE MOUNTED

STAINLESS STEEL FRAMED MIRROR

B

R1 24 X 36 WITHOUT SHELF SURFACE MOUNTED

R2 24 X 36 WITH SHELF SURFACE MOUNTED

ROBE HOOK

A

V1 1 1 /2" SINGLE SURFACE MOUNTED

V2 2" DOUBLE SURFACE MOUNTED

SEE PLAN

TO

TO

P

2' -

7"

6' -

8"

4'-0"

MA

X

3' -

4"

6' -

0"

TO

TO

P O

F F

RA

ME

6' -

2"

AC

CE

SS

IBLE

5' -

0”

4' -

0"

MA

X A

T

FIXTURE AND PARTITION MOUNTING DIAGRAM

4' -

0"

1' -

0"

URINAL EWC

PARTITION

TYPEMOUNTING -REF A3.02

C

URINAL PARTITION

FINISH FLOOR

1' -

5"

MA

X T

O

RIM

AT

A

CC

ES

SIB

LE

9"

MIN

2' -

3"

MIN

6" MAX 8" MIN

AC

CE

SS

OR

Y

3' -

0"

MA

XT

O S

PO

UT

HA

ND

LE

44"

MA

X T

OF

LU

SH 2

' - 0

12”

48”

CLEAR

3' - 0" 2' - 0"

STANDARD

ACCESSIBLE LAVATORYSECTION L1

V2

B9

4" MAX

5' -

6"

S5

WHEELCHAIR ACCESSIBLE

TOILET COMPARTMENT

W/FULL HEIGHT PARTITIONS PLAN DESIGNATION S5

CLR OPNG

34" MIN

E15

1' - 5"

5' - 7" FIN TO FIN

2' -

10

"

E16

V1

5"

3' -

2”

AT

FL

OO

R M

OU

NT

ED

30

" L

ON

G F

IXT

UR

E

3' -

4"

CL

FOLDING SHOWER SEATS

N1

SHOWER SEAT DESIGN1/2" = 1'-0"

1' - 11" MAX

MAX

1' - 4”

MAX2 1/2”

MA

X1

1/2

MA

X

1' -

3”

LINE OF COMPARTMENT ENTRY

MA

X

3”

FOLDING SHOWER SEAT

C

N1 SURFACE MOUNTED SEAT

MOP SINK FAUCET SUPPORT BRACKET

WIT

H F

AU

CE

T

CO

OR

DIN

AT

E

TYPEMOUNTING -REF A3.02

C MIN 60" LONG HOSE

HAND HELD SHOWER

SHOWER HEAD

4' -

0"

MA

X A

T

6' -

6"

AC

CE

SS

IBL

E S

HO

WE

R

4' -

0"

PAPER TOWEL DISPENSER

A

A1 SURFACE MOUNTED

4'-0

" M

AX

D

ISP

EN

SIN

G

PO

INT

SOAP DISPENSER

A

J1 SURFACE MOUNTED

TO

SP

OU

T

R4 20 X 36 WITHOUT SHELF SURFACE MOUNTED

ACCESSIBLE TOILET STALL OR SHOWER GRAB BAR WITH SEAT

24 X 42 -NON-SLIP FINISH

E14

42 X 54 -NON-SLIP FINISH

E16

C

D AT BARIATRIC CONDITIONS ONLY

TO

CL

2'

- 1

0"

2' -

10"

1' -

6"

VERTICAL GRAB BAR

E15 18"

3' - 4" TO CL

C

TY

P A

T A

LL

3' -

4"

LO

CA

TIO

NS

MA

X

3' -

4"

SHOWER STALL GRAB BAR

16 X 31 -NON-SLIP FINISH

E7

C

D

TO

CL

2'

- 9

7/8

"

2' -

10"

NON - ACCESSIBLE SHOWER

PLAN DESIGNATION SH2

SH2ELEVATION

PLAN

CO

NT

RO

L

WA

LL

FIN TO FIN

3' - 0"

EL

EV

CL

RE

CO

MM

EN

DE

D

4' -

0"

3' -

0"

6' -

6"

EQ EQ

CONTROL AREA

SHOWER HEAD

3' - 0"

OF DRAIN

REF PLAN

1 1

/2"

3"

REINFORCED MORTAR BED 2 X 2 - W0.3 X W0.3 MESH

CONTINUOUS FACED WATERPROOFING MEMBRANE - TO EXTEND INTO TOILET ROOM

CONTINUOUS UNFACED WATERPROOFING MEMBRANE - MIN 1/4"/FT SLOPE TO DRAIN (FLUID APPLIED NOT ALLOWED)

FILL WITH GRAVEL

REF PLAN FOR ELEVATIONSEALANT

THICKSET PORTLAND CEMENT MORTAR

TILE

ADDITIONAL 4" RADIUS MEMBRANE AT TILE SIDE OF SUBSTRATE, SCRIBE TO VALVE, SEAL

SEALANT

SHOWER CONTROL VALVE

PROVIDE SEALANT ALL AROUND INSIDE OF ESCUTCHEON PLATE

TILE

CONT FACED WATERPROOFING MEMBRANE (FLUID APPLIED NOT ALLOWED)

COATED GLASS MAT WATER RESISTANT BOARD

SE

CT

ION

VALVE TRIM

SECONDARY BEAD OF SEALANT TO DIVERT WATER

SEALANT

LINE OF ESCUTCHEON

PROVIDE MIN 1/4" SEALANT AND BACKER ROD, EACH SIDE OF SHOWER HEAD PIPE

SHOWER HEAD, SEAL ALL AROUND WITH SEALANT

DOUBLE SIDED TAPE SEAL AT ESCUTCHEON PLATE, TIGHT TO SHOWER HEAD

TILE

SHOWER HEAD SUPPLY FROM MIXING VALVE, SECURE TO STUDS FOR VIBRATING CONTROL

COATED GLASS MAT WATER RESISTANT BOARD

CONT FACED WATERPROOFING MEMBRANE (FLUID APPLIED NOT ALLOWED)

ADDITIONAL 4" RADIUS WATERPROOFING MEMBRANE AT TILE SIDE OF SUBSTRATE, SEAL TO SHOWER MEMBRANE

RE

FE

R T

O T

OIL

ET

A

CC

ES

SO

RY

S

CH

ED

ULE

FO

R

MO

UN

TIN

G

HE

IGH

T

CONT BED OF SILICONE SEALANT AROUND EACH FASTENER AND MOUNTING PLATE

FLOOR

GUIDE BRACKET

PROVIDE 1/2" BRASS PIPE SPACERS AT EACH SCREW LOCATION

BRACING TRACK - REF PARTITION FRAMING DETAILS AND TOILET ACCESSORIES

SHOWER SEAT - REF TOILET ACCESSORIES

RE

FE

R T

O T

OIL

ET

A

CC

ES

SO

RY

S

CH

ED

UL

E F

OR

M

OU

NT

ING

H

EIG

HT

CONT FACED WATERPROOFING MEMBRANE CUT TIGHT TO PIPE SPACERS, SEAL (FLUID APPLIED NOT ALLOWED)

GRAB BAR SHOWN - SIMILAR CONDITION AT OTHER TOILET ACCESSORIES

CONT BEAD OF SILICONE SEALANT ALL AROUND EACH FASTENER AND MOUNTING PLATE

TILE

EQUIP ITEM MOUNTING PLATE

WALL BACKING TRACK -REF PARTITION FRAMING DETAILS AND TOILET ACCESSORIES

EQ

EQ

EQ

FIN

ISH

TO

FIN

ISH

3' -

0"

+ 3/8"

+ 3/8"

+ 3/8"

+ 3/8"

0"

FLOOR DRAIN

3' - 0" 3' - 1"

CONT UNFACED WATERPROOFING MEMBRANE (FLUID APPLIED NOT ALLOWED)

GALVANIZED METAL STRIP

COATED GLASS MAT WATER RESISTANT BOARD

PREFABRICATED CPE CORNER - TYP ALL LOCATIONS. OVERLAP FLOOR AND WALL MEMBERS OVER CORNER MEMBRANE

CONT FACED WATERPROOFING MEMBRANE (FLUID APPLIED NOT ALLOWED)

CONTINUOUS UNFACED WATERPROOFING MEMBRANE -MIN 1/4"/FT SLOPE TO DRAIN (FLUID APPLIED NOT ALLOWED)

6"

3" 1

1/2

"

4"

REINFORCED MORTAR BED 2 X 2 - W0.3 X W0.3 MESH

FILL WITH GRAVEL

OF DRAIN

SEALANT

SET TRACK IN SEALANT

CONTINUOUS FACED WATERPROOFING MEMBRANE (FLUID APPLIED NOT ALLOWED)

CONTINUOUS 6" WIDE 20 GA GALVANIZED METAL STRIP

COATED GLASS MAT WATER RESISTANT BOARD

TILE

3/4

"

REF PLAN FOR ELEVATION

REF PLAN

THICKSET PORTLAND CEMENT MORTAR

COATED GLASS MAT WATER RESISTANT BOARD

TILE

CONTINUOUS FACED WATERPROOFING MEMBRANE (FLUID APPLIED NOT ALLOWED)

CONCRETE CURB

3/4

"

THIN SET PORTLAND CEMENT MORTAR

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

12:4

8:5

1 P

M

A3.20

ADAAG/ANSI TOILET

LAYOUTS AND STD

ACCESSORIES,

SHOWER AND TUB DTL

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

3" = 1'-0"01SHOWER DETAIL AT

3" DEEP SLAB DEPRESSION

3" = 1'-0"03SHOWER CONTROL VALVE

PENETRATION DETAIL

3" = 1'-0"04 SHOWER HEAD PENETRATION DETAIL

1 1/2" = 1'-0"05ACCESSIBLE SHOWER SEAT

PENETRATION DETAIL

6" = 1'-0"06TOILET ACCESSORIES

PENETRATION DETAIL AT TILED WALL

1" = 1'-0"07SHOWER REFERENCE PLAN WITH SLAB

DEPRESSION WITH CURB AND/OR THRESHOLD

1 1/2" = 1'-0"08 CORNER AT SHOWER WITH SLAB DEPRESSION

3" = 1'-0"02SHOWER DETAIL AT

3" DEEP SLAB DEPRESSION

3" = 1'-0"09 COVED TILE DETAIL

NO. DESCRIPTION DATE

Page 10: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

2" 5/8"

PA

RT

N

SC

HE

D1

/2"

1 1

5/1

6”

1 1

5/1

6”

VA

RIE

S

APPLIED STOP AT GLAZING

TYPICAL -

HOLLOW METAL

1

SAFETY GLASS LOCATIONS

DOOR LEGEND

NOTE:NOT ALL CONDITIONS SHOWN BELOW ARE APPLICABLE TO THE SCOPE OF WORK.

GLASS SCHEDULE

GLASS PRODUCT SCHEDULE FOR WALLS AND DOORS

NP - NOT PERMITTED

A - ACCEPTABLE

NR - NOT RECOMMENDED

FIRE -RATED

NON-FIRE -RATED

SAFETY NOT REQUIRED

SAFETY NOT REQUIRED

SAFETY REQUIRED

SAFETY REQUIRED

NP

NP

NP

A A A A

*

A

AA

A

NP NP

NP NP NP

NP

NR

NR

AN

NE

AL

ED

WIR

ED

TE

MP

ER

ED

LA

MIN

AT

ED

FIR

E-

RA

TE

D

SAFETY GLAZING (SG) IS REQUIRED FOR

WET AREAS CLOSE PROXIMITY TO DOORS GLAZED OPENINGS IN

DOORS

STANDING SURFACE

SG

SG

60”

ANY GLASS AROUND THESE AREAS AT 60" OR LESS ABOVE THE STANDING SURFACE IS TO BE SAFETY GLASS

SG

SAFETY GLASS IS TO BE USED FOR ALL DOORS AT HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATH TUBS OR SHOWERS

SG

SG

SG

SG

SG

SG

SG

SG

SG

SG

SG

SG

24"

60 " 24

"

60 "

DOOR NOTES

1. CONTRACTORS TO USE THE ARCHITECT'S FLOOR PLAN DESIGNATION DOOR NUMBER IN ADDITION TO THE ROOM NUMBER ON ALL SHOP DRAWING SCHEDULE SUBMITTALS.

DOOR TYPES

ACCESSORIES

DOOR AND BORROWED LITE FRAME TYPES

SCALE: 1" = 1' -0"DOOR PLAN DESIGNATION

SUFFIX FOR MULTIPLE DOORS AT A ROOM

DOOR NUMBER SAME AS ROOM NUMBER

4" MIN6" PREFERRED

OPENING MIN CLEAR1' - 6" (PULL SIDE)

CLOSER AND LATCH

1' - 0" (PUSH SIDE) MINCLEAR IF DOOR HAS

DOOR OPENING LOCATION

A. DOORS SHOWN ADJACENT TO A FLANKING WALL OR OTHER FIXED OBSTRUCTION, SHALL BE LOCATED AS SHOWN ABOVE.

B. OTHER LOCATIONS SHALL BE ON CENTERLINE OF ROOM OR AS SPECIFICALLY DIMENSIONED.

DOOR FIRE RATING101X

90

VISION PANEL OR LOUVER ACCESSORY

DOOR LEGEND

DOOR NOTES

1. CONTRACTORS TO USE THE ARCHITECT'S FLOOR PLAN DESIGNATION DOOR NUMBER IN ADDITION TO THE ROOM NUMBER ON ALL SHOP DRAWING SCHEDULE SUBMITTALS.

CONTROL JOINT AT DOOR FRAMES

SINGLE DOORS

ALIGN WITH EDGE OF DOOR FRAME CORNER ON HINGE SIDE

DOUBLE DOORS

ALIGN WITH EDGE OF DOOR FRAME CORNER

ACCESSORIES

AT

AC

CE

SS

IBLE

48”56”

LOCK BAR

VIEW PORT

NOTE:VIEW PORTS AT GUEST ROOMS ARE TO ALLOW VISION FROM THE INSIDE. VIEW PORTS AT MEETING/CONFERENCE ROOMS ARE TO ALLOW VISION FROM THE OUTSIDE.

* - NOT ALLOWED AT SHOWER ENCLOSURES

SINGLE DOORS

4' X 8' GYP BD PANEL CONFIGURATION

DOUBLE DOORS

GYPSUM BD CONFIGURATION AT DOORS

BOTTOM OF STRUCTURE

4' X 8' GYP BD PANEL CONFIGURATION

BOTTOM OF STRUCTURE

VA

RIE

S

VA

RIE

S

VA

RIE

S

EXTEND CJ TO BOTTOM OF STRUCTURE AT RATED WALLS 4" ABOVE CEILINGS AT NON-RATED WALLS

CASED OPENING

ALIGN WITH EDGE OF CASED OPENING

ARMOR PLATE

KICK PLATE

KICK/ARMOR PLATE LEGEND:K: KICK PLATEA: ARMOR PLATE1. DOOR PUSH SIDE2. DOOR PULL SIDE3. BOTH SIDES

EXAMPLE: K1 = PUSH SIDE KICK PLATE

EXTEND CJ TO BOTTOM OF STRUCTURE AT RATED WALLS 4" ABOVE CEILINGS AT NON-RATED WALLS

EXTEND CJ TO BOTTOM OF STRUCTURE AT RATED WALLS 4" ABOVE CEILINGS AT NON-RATED WALLS

FLOOR TRANSITION

A1FLUSHSINGLE

T

CASED OPENING

DASHED FRAMING FOR PAIR (DOUBLE) OF DOORS

GYP BOARD

HOLLOW METAL FRAME

GENERAL NOTES

REFERENCE FRAMING DETAILS SHEETS A3.01 FOR TRACK AND STUDS NOTES.

SEALANT AT PERIMETER OF FRAME TO MATCH FRAME PAINT COLOR

REFER TO A3.01 FOR FRAMING DETAILS

GYP BOARD

HOLLOW METAL FRAME

SEALANT AT PERIMETER OF FRAME TO MATCH FRAME PAINT COLOR

REFER TO A3.01 FOR FRAMING DETAILS

MATERIAL LEGEND

INTERIOR PAINT - IPT

IPT-01 MANUFACTURER: SHERWIN WILLIAMSFINISH COLOR: SNOWBOUNDNUMBER: SW 7004SHEEN: SEMI-GLOSS

CERAMIC TILE - CT

CT-01W MANUFACTURER: DALTILE SERIES: MODERN DIMENSIONS, GLAZED CERAMICSIZE: 4 1/4" X 12 3/4"NUMBER: 0190 COLOR: ARCTIC WHITEFINISH: SEMI-GLOSS

CT-02 MANUFACTURER: DALTILE SERIES: COLORBODY PORCELAIN, PORTFOLIOSIZE: 12" X 24"FINISH: PF06COLOR: IRON GREYNUMBER: PF06

RESILIENT WALL BASE - RB

RB-01 MANUFACTURER: JONSONITETYPE: BASEWORKS (TYPE TS) 4" FINISH COLOR: CHARCOAL WG

SOLID SURFACE - SSF

SSF-01 MANUFACTURER: WILSONARTNUMBER: 9219GSCOLOR: BROOKLYN CONCRETE

CT-02B MANUFACTURER: DALTILE SERIES: COLORBODY PORCELAIN, PORTFOLIOTRIM TYPE: COVE BASESIZE: 6X12PART: P-36C9TB & PC-36C9TB (OUTSIDE CORNER) COLOR: IRON GRAYCOLOR NUMBER: PF06

CT-02M MANUFACTURER: DALTILE SERIES: COLORBODY PORCELAIN, PORTFOLIOSIZE: 2X2 MOSAICCOLOR: IRON GRAYCOLOR NUMBER: PF06

SEALED CONCRETE - SC

SC-01 REFER TO CAST-IN-PLACE CONCRETE SPECIFICATION

NOT USED

NOT USED

NOT USED

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

12:4

8:5

1 P

M

A3.30

DOOR, SAFETY

GLAZING, LOUVERS &

FINISH INFO

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

3" = 1'-0"03INTERIOR DOOR

HEAD DETAIL - HOLLOW METAL

3" = 1'-0"04INTERIOR DOOR

JAMB DETAIL - HOLLOW METAL

FINISH MATERIALS LEGEND

ML METAL LAMINATE

OHR ORNAMENTAL HANDRAIL/RAILINGS

OM ORNAMENTAL METALS

PC ARCHITECTURAL PRECAST CONCRETE

PCP PORTLAND CEMENT PLASTER

PL PLASTIC LAMINATE

RB RESILIENT BASE

RF RESINOUS FLOORING

RS ROLLER SHADE

RSF RESILIENT SHEET FLOORING

RT RUBBER FLOOR TILE

RTF RESILIENT TILE FLOORING

SC SEALED CONCRETE

SDG SUSPENDED DECORATIVE GRID

SHL SHEET LINOLEUM FLOORING

SHR SHEET RUBBER FLOORING

SHV SHEET VINYL FLOORING

SMC SNAP-IN METAL PAN CEILINGS

SMU CALCIUM SILICATE MASONRY UNIT

SS STAINLESS STEEL

SSF SOLID SURFACE

SSM SIMULATED STONE

ST STONE

T TILE

TAC TEXTURED ACRYLIC COATING

TC TRAFFIC COATING

TER TERRAZZO

TIC TEXTURED INTERIOR COATING

TRP TRANSLUCENT RESIN PANELS

VCT VINYL COMPOSITION TILE

VT SOLID VINYL TILE

VWC VINYL WALL COVERING

WC WALL COVERING

WD WOODWORK

WDP WOOD CEILING PANEL

WF WOOD FLOORING

WP WALL PROTECTION

WTP WOOD TRIM PROFILE

XPT EXTERIOR PAINT

FINISH MATERIALS LEGEND

ACT ACOUSTICAL CEILING TILE

AF ACCESS FLOORING

AFA ANODIZED FINISHED ALUMINUM

AMC ACOUSTICAL METAL PAN CEILING PANEL

AMF ARCHITECTURAL METAL FINISH

AMU ADHERED MASONRY VENEER

AP ACOUSTICAL WALL PANEL

BP BRICK PAVING

CF CONCRETE FINISH

CMU CONCRETE MASONRY UNIT

CP CARPET

CPT CARPET TILE

CRPL CHEMICAL RESISTANT PLASTIC LAMINATE

CSM CAST STONE MASONRY

CT CERAMIC TILE

CTB CERAMIC TILE BASE

DEFS DIRECT APPLIED EXTERIOR FINISH SYSTEM

EC ELASTOMERIC COATING

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EPT EPOXY PAINT

FP FABRIC WRAPPED PANEL

FRP FIBERGLASS REINFORCED PANEL

FWC FABRIC WALL COVERING

GL GLAZING

GMU GLASS MASONRY UNIT

GRC GLASS-FIBER REINFORCED CONCRETE PANELS

GRG GLASS-FIBER REINFORCED GYPSUM

GRP GLASS-FIBER REINFORCED PLASTIC

GVP GYPSUM VENEER PLASTER

GYP GYPSUM WALL BOARD

HB HORIZONTAL BLIND

HPC HIGH PERFORMANCE COATING

ICP INTERLOCKING PRECAST CONCRETE PAVING

IPT INTERIOR PAINT

ITF INTERLOCKING RUBBER TILE FLOORING

LT LINOLEUM FLOOR TILE

MCP METAL CEILING PANEL

MIC MULTICOLORED INTERIOR COATINGS

GENERAL NOTES - FLOOR TRANSITIONS THICK SET

1 REFERENCE INTERIOR DESIGN SELECTIONS FOR DEFINITION OF INTERIOR MATERIAL DESIGNATIONS.

2 ALL INTERIOR HOLLOW METAL DOOR AND WINDOW FRAMES SHALL BE PAINTED IPTXX UNLESS NOTED OTHERWISE.

3 R = REFERENCE REMARKS.

4 ALL CASEWORK SHALL HAVE PLXX ON THE CABINETS AND PLXX ON THE COUNTERTOPS AND BACKSPLASH UNLESS NOTED OTHERWISE.

5 ALL GYP BOARD SOFFITS SHALL BE PAINTED IPTXX UNLESS NOTED OTHERWISE.

6 ALL METAL PORTIONS OF STAIRS SHALL BE PAINTED IPTXX UNLESS NOTED OTHERWISE.

7 REFERENCE A2 SERIES DRAWINGS FOR FLOOR PATTERN/FINISH EXTENT PLANS.

8 REFERENCE A3 SERIES DRAWINGS FOR MILLWORK INFORMATION.

9 REFERENCE A3 SERIES DRAWINGS FOR INTERIOR SPECIALTY ELEVATIONS.

10 REFERENCE A3 FOR TYPICAL FLOORING TRANSITION DETAILS.

11 WELDING ROD AT WELDED SEAMS IN SHEET VINYL SHALL MATCH THE DARKER OF THE SHEET VINYL COLORS AT SEAMS THAT DIVIDE TWO COLORS UNLESSNOTED OTHERWISE.

12 REFERENCE A2 SERIES DRAWINGS FOR TYPE AND PLACEMENT OF WALL PROTECTION.

LOCATION

FLOOR BASE

WALLS

CEILING REMARKSRE

VIS

ION

RO

OM

NU

MB

ER

ROOM NAME NORTH EAST SOUTH WEST

101 HSK CT-02 CT-02B IPT-01 IPT-01 IPT-01 IPT-01 IPT-01 4'-0" WAINSCOTING AT NORTH, SOUTH, AND WEST WALLS

102 SHOWER ROOM CT-02, CT02M CT-02B IPT-01 CT-01 CT-01 CT-01 IPT-01 CT-02M IN SHOWERS, CT-02 IN AISLE

103 WASH ROOM CT-02 CT-02B IPT-01 IPT-01 IPT-01 IPT-01 IPT-01

104 UTILITY SINK CT-02 CT-02B IPT-01 CT-01 IPT-01 CT-01 IPT-01

105 TOILET ROOM CT-02 CT-02B IPT-01 IPT-01 IPT-01 IPT-01 IPT-01

106 MECH SC-01 RB-01 IPT-01 IPT-01 IPT-01 IPT-01 IPT-01

107 HSK CT-02 CT-02B IPT-01 IIPT-01 IPT-01 IPT-01 IPT-01 4'-0" WAINSCOTING ALL WALLS

DOOR SCHEDULE

RE

VIS

ION

DO

OR

NU

MB

ER

WID

TH

HE

IGH

T

DO

OR

TY

PE

FR

AM

E T

YP

E

MATERIALS AND FINISHES DETAILS

LO

CK

FU

NC

TIO

N

CO

MM

EN

TS

DO

OR

NU

MB

ER

DO

OR

MA

TE

RIA

L

DO

OR

FIN

ISH

FR

AM

E M

AT

ER

IAL

FR

AM

E F

INIS

H

HE

AD

JA

MB

SIL

L

LEVEL 1

- 101 2' - 8" 7' - 0" A1 HM HM IPT - 01 HM IPT - 01 A3.30/03 A3.30/04 - STOREROOM 101

- 103 3' - 6" 7' - 0" A1 HM HM - HM - A3.30/03 A3.30/04 - CLASSROOM SEE EXTERIOR ELEVATIONS FOR FINISHES 103

- 104 3' - 6" 7' - 0" A1 HM HM - HM - A7.01/16 A7.01/03 & 16 - CLASSROOM SEE EXTERIOR ELEVATIONS FOR FINISHES 104

- 106 3' - 6" 7' - 0" A1 HM HM - HM - A7.01/16 A7.01/03 & 16 - STOREROOM SEE EXTERIOR ELEVATIONS FOR FINISHES 106

- 107 3' - 0" 7' - 0" A1 HM HM IPT - 01 HM IPT - 01 A3.30/03 A3.30/04 - STOREROOM 107

DOOR HARDWARESUBCONTRACTOR TO COORDINATE W/ OWNERSHIP AND FIELD CONDITIONSFINISH: 626 TYPICAL - INDICATED IN PARENTHESIS (626)

BASIS OF DESIGN:LOCKSET: SARGENT 7900 SERIES OR SIMILAR (626)

FUNCTION: SEE DOOR SCHEDULE - NO DEADBOLTLEVER: BLROSE: CECYLINDER: MATCH RESERVE SPEC W/ CONSTRUCTION CORE

HINGE: (3) MCKINNEY T4A3786 4 1/2" OR SIMILAR (626)KICKPLATE: ROCKWOOD K1050 10" OR SIMILAR (626)INTERIOR DOOR STOP: ROCKWOOD 406 OR SIMILAR (626)EXTERIOR DOOR STOP: RIXSON 10-X36 (630)

PROVIDE THE FOLLOWING AT EXTERIOR DOORS ONLY:CLOSER: NORTON CPS7500 OR SIMILAR (626)THRESHOLD: PEMKO 271A OR SIMILAR GASKETING: PEMKO 2893AV OR SIMILARSWEEP: PEMKO 57AV OR SIMILAR

3" = 1'-0"01 INTERIOR 8" CMU JAMB DETAIL

3" = 1'-0"02 INTERIOR 8" CMU HEAD DETAIL

TYPE FT-5

NO. DESCRIPTION DATE

Page 11: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

A3

.50

02

2' - 0 3/4"

19”

MIN

CL

EA

R

2' -

3"

TO

TO

P O

F S

INK

RIM

2' -

10

"

COUNTERTOP AND SKIRT

SEALANT AROUND EDGE OF SINK

FINISH WALL

ACCESSIBLE FAUCET

BACKSPLASH

ACCESSIBLE SINK

LINE OF BASE CABINET BEYOND

FINISHED FLOOR

MAX

25"

PROVIDE UNDERSINK PIPING INSULATION

TYPICAL CABINET DIMENSIONS

NOTE: ALL CABINET DIMENSIONS GIVEN ARE NOMINAL. SCHEDULED CEILING HEIGHT

84"

60"54"48"

36"

34"

30"

FF

2' - 0"

MIN

2' -

3"

APRON / KNEE SPACE

PLAM - PLASTIC LAMINATE UNOCP - CAST PLASTIC (SOLID SURFACING MATERIAL)ER - EPOXY RESINSS - STAINLESS STEELST - STONE

SS

3" MAX

1 1/2" MIN

1/8

SCRIBE TO WALL

FILLER PANEL

LINE OF WALL

DOOR

PLAN - WALL FILLER PANEL AT END WALL

APLAN - END PANEL

B

DOOR

FLUSH

END PANEL

1 1

/4”

5 1

/2”

COUNTERTOP

APRON

36

" O

R 3

4"

AF

F

ARCHITECTURAL CABINET TYPICAL DETAILS

APRON

COUNTERTOP

1 1

/4”

1 1

/2”

30

" A

FF

1 1

/4”

1 1

/2”

30

" A

FF

COUNTERTOP

PENCIL DRAWER

SECTIONS - KNEE SPACE / APRON

CPLAN - INSIDE CORNER

FILLER PANELS BETWEEN ADJACENT CABINETS

D

4" MAX

2 1/4" MIN

4"

MA

X

2 1

/4"

MIN

1/8”

DOOR

DOOR OR DRAWER

FILLER PANEL

1/8

CABINET PULL

DRAWER FRONT

DOOR

STRETCHER

SECTION - DOOR TO DRAWERDRAWER TO DRAWER SIM

ESECTION - OPEN

CABINET TO DRAWER

F

CABINET PULL

DRAWER FRONT

END PANEL OR CABINET BEYOND

STRETCHER

1 1

/4”

1/8

CABINET PULL

DOOR

COUNTERTOP

1/8”

1/8

”2

1/2

DOOR

VALANCE

CABINET PULL

SECTION -COUNTERTOP WITH

DOOR BELOW

GSECTION - UPPER CABINET WITH DOORS AT VALANCE

H

1/8”

2 3

/8”

SECTION - UPPER CABINET OPEN SHELF

VALANCE

I

END PANEL OR CABINET BEYOND

VALANCE

2 3

/8”

END PANEL

CABINET BOTTOM

SECTION - UPPER CABINET AT EXPOSED

SIDE

J

1/8”

1/8

DOOR

CABINET PULL

PLAN - CABINET TO CABINET AT DOORS

KPLAN - DOOR TO

DOOR

L

1/8”

DOOR

CABINET PULL

FIN CLG

FASCIA PANEL WITH INTEGRAL SUPPORT

END PANEL

SECTION - UPPER CABINET FASCIA PANEL RETURN

M

1”

2”

FASCIA PANEL WITH INTEGRAL SUPPORT AT 36" OC MAX (MIN 2)

DOOR

GYP BD FURR DOWN

FURR DOWN SECTION AT UPPER CABINET

N

SCRIBE TO BACK WALL

CABINET BOTTOM

LINE OF WALL

SECTION - UPPER CABINET - BOTTOM OF

BACK WALL

O

MIN1”

CABINET COUNTERTOP

LINE OF WALL

PLAN - CASEWORK AT WALL ADJACENT

P

LINE OF BASE CABINET BELOW

R 2"

PLAN - AT OUTSIDE CORNER OF

COUNTERTOPS

Q

END PANEL

SCRIBE TO BACK WALL

END PANEL AT WALL

R

BASE CABINET

COUNTERTOP

COUNTERTOP EXTENSION AT END OF BASE CABINET

S

1/8

4”

4”

DOOR

EXTEND WALL BASE UNO

FLOOR

SECTION -CABINET DOOR

AT BASE

T

EQUIP

END PANEL

SECTION - END CAP

UUPPER CABINET FASCIA

PANEL CLOSURE

V

END PANEL

SECTION - END CAP

W

END PANEL

LINE OF BACK WALL

SCRIBE TO WALL

PLAN - END PANEL AT BACK

WALL

X

PLANMAX6”

SECTION

3”

PLAN

4”

COUNTERTOP SUPPORT BRACKET 36" OC MAX

MOUNTING SUPPORT TYPE B

3/4" PLAM COVERED BACKING

SECTION - COUNTERTOP SUPPORT BRACKET AT KNEE

SPACE

1/8

CLEAR MUTE

2”

CLEAR MUTE

CLEAR MUTE

CLEAR MUTE

3/8

PLAM TO MATCH CAB

FIN CLG

FASCIA PANEL WITH INTEGRAL SUPPORT AT 36" OC MAX (MIN 2)

DOOR

3/8

PLAM TO MATCH CAB

CABINET LEGEND

CABINET ELEVATION LEGEND

SCHEDULED CLG HEIGHT

84"

60"

54"

48"

36"

34"

30"

FF

A

L

K

G G

P

A

K

LL

K

N V

B

36

36

30

I O H

T

B

U

U

C C F

RE

AS

EQUIP

KS

36a

36 18 18 30

SS

M

X

J

X

S

FURR DOWN OR FASCIA PANEL

ADJUSTABLE SHELF INDICATION

COUNTERTOP DESIGNATION IF OTHER THAN PLASTIC LAMINATE

CABINET ELEVATION ABBREVIATION

CABINET WIDTH AND ACCESSORY

VIEW ICON INDICATES ORIENTATION OF VIEW ON PLAN

ROOM NAMEROOM NUMBER

ACCESSORY LEGEND (LOWER CASE LETTERS ONLY)

a - DRAWER / CABINET LOCKb - WASTE CHUTE - 8" DIA HOLE IN COUNTERTOPc - SLIDING WRITING SHELFd - GROMMETe - P-LAM CLAD PANEL, INSERT TO MATCH CABINET DOOR / DRAWERS

ELEVATION ABBREVIATION LEGEND

AS - ACCESSIBLE SINKF - FILE DRAWERFS - FIXED SHELFKB - KEYBOARD DRAWERKS - KNEE SPACEG - GLASS FRONTTL - TASK LIGHTING

CABINET ELEVATION LEGENDSCHEDULED CLG HEIGHT

84"

60"

54"

48"

36"

34"

30"

FF

KS

ROOM NAMEROOM NUMBER

A

A

P

K

L

N V

B

H O I

G

C

K

L

B W

Q

T

FURR DOWN OR FASCIA PANEL

ADJUSTABLE SHELF INDICATION

CABINET ELEVATION ABBREVIATION

VIEW ICON INDICATES ORIENTATION OF VIEW ON PLAN

CABINET ELEVATION LEGENDSCHEDULED CLG HEIGHT

84"

60"

54"

48"

36"

34"

30"

FF

ROOM NAMEROOM NUMBER

SS

C E

R BD

AS

COUNTERTOP DESIGNATION IF OTHER THAN PLASTIC LAMINATE

CABINET ELEVATION ABBREVIATION

VIEW ICON INDICATES ORIENTATION OF VIEW ON PLAN

CABINET GENERAL NOTES

1. CABINET WIDTHS TO BE BASED ON MODULE INCREMENTS OF 3" UNO.

2. PROVIDE FILLER PANELS TO FINISH OUT TO SCRIBE CABINETS TO WALL.

3. PROVIDE FILLER PANELS AND TRIM WHERE EQUIPMENT IS LOCATED WITHIN CABINETS.

4. PROVIDE FINISHED END PANELS END RETURNS AT OPEN ENDED CABINETS, KNEE SPACES, AND ACCESSIBLE SINKS.

5. PROVIDE 1 1/2" THICK FINISHED END PANEL AT FREE STANDING END OF ACCESSIBLE SINKS AND KNEE SPACES.

6. WHEN FILLER PANELS ARE REQUIRED AT BOTH ENDS OF CASEWORK TERMINATION, BOTH FILLER PANELS SHALL BE EQUAL WIDTH.

7. PROVIDE WALL BRACKET SUPPORTS AT 36" OC MAX TO SUPPORT COUNTERTOP AT CONTINUOUS KNEE SPACE.

8. PROVIDE END SPLASH WHEN COUNTERTOP IS ADJACENT TO WALL AT SIDES.

9. PROVIDE HOLES FOR GROMMETS IN COUNTERTOPS AND AT THE FOLLOWING LOCATIONS: - 1 EACH WIRE ACCESS HOLE WITH GROMMET AT KNEE SPACE. - WIRE ACCESS HOLES WITH GROMMETS AT 38" OC FOR CONTINUOUS RUNS OF KNEE SPACE. - 1 WIRE ACCESS GROMMET BEHIND EACH KEYBOARD DRAWER. - 1 COMPUTER PAPER SLOT GROMMET BEHIND EACH PRINTER.

10. PROVIDE ADJUSTABLE SHELVES IN CABINETS AT THE FOLLOWING LOCATIONS UNO ON ELEVATIONS: - BASE CABINET - 1 SHELF - FULL HEIGHT CABINET - 5 SHELVES, 1 FIXED. - WALL CABINET - 1 SHELF AT 24" HIGH, 2 SHELVES AT TALLER CABINETS NOTE: SHELVES TO BE 3/4" THICK FOR SPANS UP TO 32" AND 1" THICK FOR SPANS UP TO 36".

11. GLASS FRONTS TO BE 1/4" THICK CLEAR TEMPERED GLASS UNO.

12. PROVIDE AN APRON AT ALL KNEE SPACES 30" OR HIGHER UNO.

FASCIA PANEL JOINTS

8'-0" MAX BETWEEN

TASK LIGHTING

R4

IPT - 01

2' -

0"

6"

BASE - 01

SSF - 01

IPT - 01

TYP6 1/4"

TYPEQ

TYPEQ

CT - 01

09

A3.20

CUSTOM FOUR COMPARTMENT STAINLESS STEEL SERVICE SINK W/ RAISED RIM - BOWL SIZE BASED ON KOHLER BALLAD K-RH20061

2' -

10

"

14' - 8"

BOWL CL

3' - 6"BOWL CL TO

J1

R4

A1

IPT - 01

BASE - 01

IPT - 01

SSF - 01

TYPEQ

TYPEQ

TYPEQ

TYPEQ

8"

6"

2' -

0"

EQ

TYP

EQ EQ EQ EQ EQ EQ EQ EQ EQ

4' -

0"

CT - 01

V1

HOSE BIB

09

A3.20

CT - 01

09

A3.20

SIM

CT - 01

09

A3.20

CT- 01

4' -

0"

08

A3.20

OPEN TO BEYOND

IPT - 01

BASE - 01

IPT - 01

IPT - 01

BASE - 01

1" = 1'-0"10

ACCESSIBLE FRONT

APPROACH SINK SECTION

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

2:2

6:5

9 P

M

A3.50

INTERIOR ELEVATIONS

AND CABINET DETAILS

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

1/4" = 1'-0"01WASH ROOM EAST ELEVATION

1/4" = 1'-0"04HEAVY DUTY SINK EAST ELEVATION

1/4" = 1'-0"02WASH ROOM WEST ELEVATION

1/4" = 1'-0"03HEAVY DUTY SINK WEST ELEVATION

1/4" = 1'-0"06SHOWER ROOM EAST ELEVATION

1/4" = 1'-0"07SHOWER ROOM SOUTH ELEVATION

1/4" = 1'-0"05SHOWER ROOM WEST ELEVATION

1/4" = 1'-0"08TOILET ROOM NORTH ELEVATION

1/4" = 1'-0"09TOILET ROOM SOUTH ELEVATION

NO. DESCRIPTION DATE

Page 12: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

LEVEL 1

100' - 0"

1 2

TO WALL FRAMING

109' - 1 1/8"

05

A5.01

ADHERED STONE MASONRY (MV-1)

EXTERIOR INSUALTION FINISH SYSTEM (EF-1)

ALUMINUM FASCIA & GUTTER (MF-2)

STANDING SEAM METAL ROOF (MF-1)

ADHERED STONE MASONRY WATERTABLE (MV-2)

HIGH PERFORMANCE WINDOWS (WN-1) W/ APPLIED FILM (FM-1) ON INTERIOR SURFACE

HM DOOR AND FRAMEMAX U VALUE: 0.37(MF-3)

SIDELIGHT (GL-1) W/ APPLIED FILM (FM-1) ON INTERIOR SURFACE

ALUMINUM DOWNSPOUT (MATCH EF-1)

ALIGN TOP OF LIGHT FIXTURE W/ FRAME HEAD

1' - 2"

EQ 8' - 0" EQ EQ8' - 0"8' - 0"8' - 0"EQ

CJ CJ CJ CJ CJ CJ

15

A7.01

16

A7.01

03

A7.01

11

A7.01

12

A7.0113

A7.01

04

A7.01BOLLARD (MF01A)REF A3.00/06 - PAINT SAFETY YELLOW

NEW MECHANICAL AIR UNIT

LEVEL 1

100' - 0"

12

TO WALL FRAMING

109' - 1 1/8"

HIGH PERFORMANCE WINDOWS (WN-1) W/ APPLIED FILM (FM-1) ON INTERIOR SURFACE

HM DOOR AND FRAMEMAX U VALUE: 0.37(MF-3)

SIDELIGHT (GL-1) W/ APPLIED FILM (FM-1) ON INTERIOR SURFACE

ADHERED STONE MASONRY (MV-1)

EXTERIOR INSUALTION FINISH SYSTEM (EF-1)

ALUMINUM GUTTER AND FASCIA (MF-2)

STANDING SEAM METAL ROOF (MF-1)

ADHERED STONE MASONRY WATERTABLE (MV-2)

ALUMINUM DOWNSPOUT (MATCH EF-1)

ALIGN TOP OF LIGHT FIXTURE W/ FRAME HEAD

1' - 2"

EQ 8' - 0" 8' - 0" EQ EQ8' - 0"8' - 0"EQ

CJ CJ CJ CJ CJ CJ

15

A7.01

16

A7.01

03

A7.01 11

A7.01

12

A7.01

13

A7.01

03

A7.01

05

A5.01

BOLLARD (MF01A) -PAINT SAFETY YELLOW

MECHANICAL AIR UNIT

LEVEL 1

100' - 0"

B A

MECHANICAL EXHAUST FAN

TO WALL FRAMING

109' - 1 1/8"

ADHERED STONE MASONRY (MV-1)

EXTERIOR INSUALTION FINISH SYSTEM (EF-1)

ALUMINUM FASCIA & GUTTER(MF-2)

STANDING SEAM METAL ROOF (MF-1)

ADHERED STONE MASONRY WATERTABLE (MV-2)

HIGH PERFORMANCE WINDOWS (WN-1) W/ APPLIED FILM (FM-1) ON INTERIOR SURFACE

HM DOOR AND FRAMEMAX U VALUE: 0.37(MF-3)

8' -

0"

EQ 8' - 0" EQ

CJ CJ

15

A7.01

16

A7.01

03

A7.01

13

A7.01

11

A7.01

12

A7.01

REF. A7.01/ 17

LEVEL 1

100' - 0"

BA

TO WALL FRAMING

109' - 1 1/8"

BU

ILD

ING

HE

IGH

T

13

' - 3

3/8

"

EQ

EQ

12

' - 0

"

EQ 8' - 0" 8' - 0" EQ

CJ CJ CJ

ATTIC STYLE TRUSS BEYOND SHOWN DASHED

MECHANICAL DUCT PENETRATIONS

LIGHT FIXTURE

REF. A7.01/ 17

MECHANICAL AIR UNIT

BOLLARD (MF01A) -PAINT SAFETY YELLOW

LEVEL 1

100' - 0"

B

TO WALL FRAMING109' - 1 1/8"

EIFS(EF-1)

ADHERED STONE MASONRY(MV-1)

ADHERED STONE WATERTABLE(MV-2)

MIN R-19 BATT INSULATION IN STUD CAVITY

2" SEMI-RIGID INSULATION

STRUCTURAL FOUNDATION WALL

2" RIGID INSULATION

2X6 NOMINAL WOOD STUDS

STANDING SEAM METAL ROOF(MF-1)

6" GRAVEL COURSE

CONCRETE SLAB ON GRADE

MIN R-38 BATT INSULATION AT ROOF

1" AIR VENT CHUTE AND HEEL BAFFLE

5

12

METAL PANEL SOFFIT(MF-2)

ALUMINUM GUTTER & FASCIA(MF-2)

6"

GRADE

A2.02/03

A7.01/11

SIM

A7.01/02

EXTERIOR FINISH SELECTIONS (BASIS OF DESIGN)

ADHERED MASONRY VENEER

MV-1MFG: CULTURED STONESTYLE: DRESSED FIELDSTONECOLOR: ASPEN

MV-2MFG: CULTURED STONESTYLE: WATERTABLE / SILLCOLOR:

EXTERIOR INSULATION & FINISH SYSTEM (EIFS)

EF-1COLOR: RED TO MATCH EXISTING

MIN PERFORMANCE VALUES:R: 7.2

METAL FINISH

MF-1MFG: CENTRIATYPE: CUSTOM COLOR (3 COAT SYSTEM INCLUDING PRIMER, PVDF COLOR COAT, AND PVDF CLEAR COAT)COLOR: RED TO MATCH EXISTING ROOF

OWNER TO SELECT (GRAY OR TAUPE)

MF-2 CENTRIATYPE: CUSTOM COLOR (3 COAT SYSTEM INCLUDING PRIMER, PVDF COLOR COAT, AND PVDF CLEAR COAT)COLOR: LIGHT GRAY TO MATCH EXISTING FASCIA & SOFFIT

GLASS

GL-1TYPE: 1" INSULATEDCOLOR: CLEAR

MAX SYSTEM PERFORMACE VALUES:U: 0.38SHGC: 0.40

MF-3TYPE: PAINT MPI EXT 5.1M (SEE PAINTING SPECIFICATION)COLOR: LIGHT BLUE TO MATCH EXISTING HM DOORS AND FRAMES.

APPLIED FILM

FM-1MFG: 3MTYPE: POLYESTERCOLOR: SXWF-WM WHITE MATTE

EXTERIOR WINDOWS

WN-1MFG: CASCADIATYPE: FIBERGLASS 400 SERIESCOLOR: WHITE

MAX SYSTEM PERFORMANCE VALUESU: 0.38SHGC: 0.40

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

1:1

1:5

3 P

M

A5.01

EXTERIOR ELEVATIONS

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

1/4" = 1'-0"01SOUTH ELEVATION

1/4" = 1'-0"02NORTH ELEVATION

1/4" = 1'-0"03EAST ELEVATION

1/4" = 1'-0"04WEST ELEVATION

1/2" = 1'-0"05TYPICAL WALL SECTION

NO. DESCRIPTION DATE

Page 13: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

CASING BEAD WITH PERFORATIONS AT 12" OC FOR WEEPING

THIN MASONRY

3/4" PORTLAND CEMENT PLASTER

METAL LATH

EXTERIOR CEMENT BOARD SHEATHING

AIR / WATER BARRIER - SEE GRADE LEVEL TERMINATION DETAIL FOR AIR BARRIER TERMINATION AT GRADE

MORTAR SETTING BED

EXTERIOR PLYWOOD SHEATHING

2" SEMI-RIGID INSULATION

MESH TAPE AT ALL JOINTS IN CEMENT BOARD SHEATHING

MORTAR

"Z" FURRING

FIBERGLASS CLIP

CONT SHEET METAL DRIP FLASHING - PROVIDE END DAMS AT ALL DRIP FLASHING TERMINATIONS UNO

GENERAL NOTES

CONTROL JOINTS (CJ) AND EXPANSION JOINTS (EJ) TO BE PLACED AT:1. AS REQUIRED TO ALIGN WITH JOINTS IN SUBSTRATES.2. AS REQUIRED TO DIVIDE PLASTER INTO AREAS (PANELS) OR FOLLOWING MAXIMUM SIZES

WITH LENGTHS-TO-WIDTH RATIOS OF NOT GREATER THAN 2-1/2:1:

A. VERTICAL SURFACES: 144 SQ FT (13.4 SQ M)B. HORIZONTAL SURFACES: 100 SQ FT (9.3 SQ M)

3. AT DISTANCES BETWEEN CONTROL JOINTS OF NOT GREATER THAN 12 FT (3.6M) ON CENTERS.4. WHERE CONTROL JOINTS OCCUR IN SURFACE OF OTHER CONSTRUCTION DIRECTLY BEHIND PLASTER.5. WHERE PLASTER AREAS CHANGE DIMENSIONS, TO DELINEATE RECTANGULAR-SHAPED AREAS (PANELS) AND TO RELIEVE STRESS THAT OCCURS AT CORNER FORMED BY

DIMENSION CHANGE.

VAPOR RETARDER

5/8" GYP BOARD

R-19 BATT INSULATION

SLAB ON GRADE

THIN MASONRY ON PORTLAND CEMENT PLASTER SYSTEM

BARRIER FLASHING TAPE

BELOW SLAB VAPOR RETARDER

MA

X

45.0

1/2" CEMENT BOARD

1' -

4"

6"

LA

P

FIBERGLASS CLIP

RUBBERIZED ASPHALT FLASHING

CONTINUOUS TERMINATION BAR

3/4" PORTLAND CEMENT PLASTER

AIR / WATER BARRIER

BARRIER FLASHING TAPE

LIQUID MEMBRANE

BARRIER FLASHING TAPE

LATH

SHEET METAL FLASHING W/ HEMMED EDGE TO BE CONT VISIBLE

GEOMETRY OF END DAMS SHOWN DASHED - INSTALL END DAMS AT EACH FLASHING TERMINATION

"Z" FURRING

CONT SHEET METAL DRIP FLASHING WITH HEMMED EDGE - PROVIDE END DAM AT ALL FLASHING TERMINATION UNO

6"

GRADE

2" SEMI-RIGID INSULATION

NOTE:REFER TO ADHERED MASONRY SYSTEM COMPONENTS DETAIL FOR SYSTEM COMPONENTS.

3"

SEALANT WITH BOND BREAKER TAPE

THIN MASONRY ON PORTLAND CEMENT PLASTER SYSTEM

BARRIER FLASHING TAPE

VAPOR RETARDER

GYP BOARD

HOLLOW METAL DOOR FRAME

SEALANT

2X6 NOMINAL WOOD STUDS

R-19 BATT INSULATION

NOTE:REFER TO ADHERED MASONRY SYSTEM COMPONENTS DETAIL FOR SYSTEM COMPONENTS.

2" SEMI RIGID INSULATION

"Z" FURRING

CONT 2 1/2" X 2 1/2" 12 GA GALV STEEL ANGLE

FIBERGLASS CLIP

AIR / WATER BARRIER

1/2" CEMENT BOARD

SEALANT AND BACKER ROD

SHEET METAL CONTINUOUS FLASHING

3"

THIN MASONRY ON PORTLAND CEMENT PLASTER SYSTEM

BARRIER FLASHING TAPE

1/2" CEMENT BOARD

AIR / WATER BARRIER

NOTE:REFER TO ADHERED MASONRY SYSTEM COMPONENTS DETAIL FOR SYSTEM COMPONENTS.

2X6 NOMINAL WOOD STUDS

SEALANT AND BACKER ROD

CONTROL JOINT

CORNER BEAD

GYP BD

R-19 BATT INSULATION

2" SEMI-RIGID INSULATION

VAPOR RETARDER

REF EXTERIOR ELEVATIONS

3"

3"

THIN MASONRY ON PORTLAND CEMENT PLASTER SYSTEM

AIR / WATER BARRIER

CONTROL JOINT

BUILDING PAPER TO BE CONTINUOUS BEHIND CONTROL JOINT

R-19 BATT INSULATION

GYP BD

SEALANT AND BACKER ROD

NOTE:REFER TO ADHERED MASONRY SYSTEM COMPONENTS DETAIL FOR SYSTEM COMPONENTS.

VAPOR RETARDER2" SEMI-RIGID INSULATION

3"

SEAL WATERTIGHT INTERSECTION OF VERTICAL EXPANSION JOINT AND HORIZONTAL CASING BEAD

PERFORATIONS AT 12" OC

CLIP CASING BEAD AT CONTROL JOINT TO ALLOW FOR DRAINAGE

CONTROL JOINT

NOTE:SOME COMPONENTS OMITTED FOR CLARITY - REFER TO THE TYPICAL GRADE LEVEL TERMINATION DETAIL FOR WEEPS AND FLASHING AT SILL TERMINATION.

FINISH COAT

THE EXTERIOR INSULATION AND FINISH

SYSTEM (EIFS)

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD

BASE COAT

REINFORCING MESH

BASE COAT

TROWEL APPLIED ADHESIVE APPLIED TO BACK OF EPS BOARD

THE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) IS DESIGNED AS AN INTEGRATED SYSTEM REQUIRING COORDINATION OF INSTALLATION AND INTERFACE OF SYSTEM COMPONENTS. THE SYSTEM FUNCTIONS AS A FLEXIBLE, EXTERIOR INSULATING ENVELOPE WITH AN INNER INSULATING LAYER AND AN OUTER PROTECTIVE COATING LAYER. THE SYSTEM IS DESIGNED AS A BARRIER WALL SYSTEM, IT IS DETAILED TO PREVENT WATER FROM ENTERING THE SYSTEM.

THE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) IS MADE UP OF, BUT NOT LIMITED TO THE FOLLOWING:

- SUBSTRATE- MESH TAPE- AIR / WATER BARRIER- FLASHING TAPE- EXPANDED POLYSTYRENE (EPS) INSULATION BOARD- TROWEL APPLIED ADHESIVE- BASE COAT- REINFORCING MESH- FINISH COAT- PRIMER

EIFS SYSTEM AIR / WATER BARRIER

CONT 4" WIDE STRIP OF FLASHING TAPE AT PERIMETER OF ALL OPENINGS

MESH TAPE

PLYWOOD SUBSTRATE

EIFS SYSTEM

BACKWRAP MESH THEN OVERLAP 2 1/2" MIN - TYPICAL AT SYSTEM RETURNS

COLOR COORDINATED PRIMER/COATING AT SYSTEM RETURNS

SEALANT AND BACKER ROD

SILL PAN END DAM BEYOND

BARRIER FLASHING TAPE

SILL PAN FINISHED TO MATCH WINDOW SYSTEM

3/4

"

RO

AIR / WATER BARRIER

4"

THIN MASONRY WATERTABLE W/ DRIP EDGE

THIN MASONRY ON PORTLAND CEMENT PLASTER SYSTEM

2"

CONT SHEET METAL FLASHING - PROVIDE END DAM AT ALL TERMINATIONS

SEALANT

SHIM

2"

SLOPE 1:2

FACE OF EIFS BEYOND

3"

EIFS SYSTEM

SEALANT AND BACKER ROD

COLOR COORDINATED PRIMER/COATING AT SYSTEM RETURNS

BARRIER FLASHING TAPE

BACKWRAP MESH THEN OVERLAP 2 1/2" MIN - TYPICAL AT SYSTEM RETURNS

MULLION CLOSURE TRIM

RO

SEALANT

4"

1"

3/4

"

VAPOR RETARDER

GYP BOARD

R-19 BATT INSULATION

2 1/4"

SEALANT AND BACKER ROD

COLOR COORDINATED PRIMER/COATING AT SYSTEM RETURNS

BARRIER FLASHING TAPE

BACKWRAP MESH THEN OVERLAP 2 1/2" MIN - TYPICAL AT SYSTEM RETURNS

EIFS SYSTEM

SEALANT

2X HEADER AS SCHEDULED

RO

3/4

"

1"

4"

SLOPE 1:2

VAPOR RETARDER

R-19 BATT INSULATION

GYP BOARD

2 1/4"

EIFS SYSTEM

BACKWRAP MESH THEN OVERLAP 2 1/2" MIN - TYPICAL AT SYSTEM RETURNS

SEALANT AND BACKER ROD EACH SIDE

COLOR COORDINATED PRIMER/COATING AT SYSTEM RETURNS

EIFS SYSTEM

3/4

"3

/4"

2 1/4"

HOLLOW METAL FRAME

RO

GYP BOARDPLYWOOD SHEATHING

2x6 NOMINAL WOOD STUDS

SEALANT AND BOND BREAKER TAPE

SEALANT

BARRIER FLASHING TAPE

VAPOR RETARDER

R-19 BATT INSULATION

4"

1"

3/4

"

RAIN DRIP

HOLLOW METAL FRAME

RO

GYP BOARD

PLYWOOD SHEATHING

3/4

"

SEALANT AND BOND BREAKER TAPE

SEALANT

BARRIER FLASHING TAPE

4"

2X WOOD HEADER

VAPOR RETARDER

1"

SLOPE 1:2

2 1/4"

NOTE: REFER TO DETAIL A7.01/10 FOR BALANCE OF SYSTEM COMPONENTS.

EXTERIOR PLYWOOD SHEATHING

AIR/WATER BARRIER

BARRIER FLASHING TAPE ALL SIDES

CONTINUOUS WELD

DUCT OR INSULATED PIPE PENETRATION WALL SYSTEM

12 GA STAINLESS STEEL COLLAR - ALL SIDES

0.062" X 6" EXTRUDED SILICONE SHEET SET IN SILICONE SEALANT

CONTINUOUS STAINLESS STEEL DRAW BAND

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/1

4/2

020

12:4

8:5

9 P

M

A7.01

EXTERIOR DETAILS

14 FEBRUARY 2020

22564.000

CONSTRUCTION

DOCUMENTS

3" = 1'-0"01ADHERED MASONRY

SYSTEM COMPONENTS

3" = 1'-0"02 GRADE LEVEL TERMINATION

3" = 1'-0"03HOLLOW METAL

DOOR FRAME AT JAMB

3" = 1'-0"04 TYPICAL CORNER DETAIL PLAN

3" = 1'-0"05 VERTICAL CONTROL JOINT

3" = 1'-0"06 CONTROL JOINT TERMINATION

NTS10 EIFS SYSTEM COMPONENTS

3" = 1'-0"11 WINDOW SILL

3" = 1'-0"12 WINDOW JAMB

3" = 1'-0"13 WINDOW HEAD

3" = 1'-0"14 PENETRATION

3" = 1'-0"16 EXTERIOR EIFS JAMB DETAIL

3" = 1'-0"15 EXTERIOR EIFS HEAD DETAIL

3" = 1'-0"17 DUCT OR INSULATED PIPE PENETRATION

NO. DESCRIPTION DATE

Page 14: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

STRUCTURAL NOTES :

A. GENERAL

1. THE STRUCTURAL NOTES ARE INTENDED TO COMPLEMENT THE PROJECT SPECIFICATIONS WHICH ARE PART OF THE CONSTRUCTION DOCUMENTS. SPECIFIC NOTES AND DETAILS ON THE DRAWINGS SHALL GOVERN OVER THE STRUCTURAL NOTES AND TYPICAL DETAILS.

2. THESE DRAWINGS (AND, WHERE APPLICABLE, ACCOMPANYING WRITTEN SPECIFICATIONS) ARE THE ONLY CONTRACT DOCUMENTS PROVIDED BY ARW ENGINEERS FOR THE PROJECT REPRESENTED HEREIN. NOTHING IN ANY DIGITAL MODEL OR DIGITAL FILE RELATED TO THIS PROJECT SHALL BE TAKEN TO SUPERSEDE ANY INFORMATION SHOWN IN THESE DRAWINGS (INCLUDING, BUT NOT LIMITED TO, DIMENSIONS, SIZES, ETC).

3. THE ARCHITECTURAL DRAWINGS ARE THE PRIME CONTRACT DRAWINGS. THE STRUCTURAL DRAWINGS ARE SUPPLEMENTARY TO AND MUST BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS AND OTHER CONSULTANTS DRAWINGS. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY WORK INVOLVED. IN CASE OF CONFLICT, FOLLOW THE MOST STRINGENT REQUIREMENT AS DIRECTED BY THE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER.

4. SEE SPECIFICATIONS FOR REQUIRED SUBMITTALS. SUBMITTALS SHALL BE MADE IN A TIMELY MANNER AS INDICATED IN SPECIFICATIONS. REVIEW OF SUBMITTALS BY ARW ENGINEERS IS FOR GENERAL COMPLIANCE ONLY AND IS NOT INTENDED AS APPROVAL. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SIZES, DIMENSIONS, AND ELEVATIONS ON SUBMITTALS AS RELATED TO DESIGN DOCUMENTS. PREPARATION OF SHOP DRAWINGS FOR STRUCTURAL ELEMENTS WILL REQUIRE INFORMATION (I.E. DIMENSIONS, ETC.) FOUND IN THE ARCHITECTURAL, STRUCTURAL, AND OTHER CONSULTANTS DRAWINGS.

5. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE SITE. IF ACTUAL CONDITIONS DIFFER FROM THOSE SHOWN ON CONTRACT DOCUMENTS, CONTRACTOR SHALL NOTIFY ARCHITECT PRIOR TO FABRICATION OR CONSTRUCTION OF ANY AFFECTED ELEMENTS.

6. THE CONTRACTOR SHALL COORDINATE AND VERIFY ALL LOCATIONS AND SIZES OF MECHANICAL EQUIPMENT OR OTHER EQUIPMENT BEFORE FABRICATING AND ERECTING STRUCTURAL ELEMENTS. SIZES AND LOCATIONS THAT DIFFER FROM THOSE SHOWN ON THE CONTRACT DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT.

7. THE CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST TO THE ARCHITECT FOR ARCHITECT AND/OR ENGINEER APPROVAL BEFORE PROCEEDING WITH ANY CHANGES, MODIFICATIONS, OR SUBSTITUTIONS.

8. OBSERVATION VISITS TO THE SITE BY ARW ENGINEERS FIELD REPRESENTATIVES SHALL NEITHER BE CONSTRUED AS INSPECTION NOR APPROVAL OF CONSTRUCTION.

9. DURING AND AFTER CONSTRUCTION, BUILDER AND/OR OWNER SHALL KEEP LOADS ON STRUCTURE WITHIN THE LIMITS OF DESIGN LOADS AS NOTED IN THESE DOCUMENTS.

10. TYPICAL OR SIMILAR DETAILS AND SECTIONS SHALL APPLY WHERE SPECIFIC DETAILS ARE NOT SHOWN. TYPICAL OR SIMILAR DETAILS REFER TO THE CONDITION ADDRESSED AND ARE NOT NECESSARILY DETAILS LABELED “TYPICAL” OR “SIMILAR” IN THE PLANS AND DOCUMENTS.

11. DRAWINGS AND DETAILS HAVE BEEN PREPARED WITH THE INTENT TO VISUALLY REPRESENT INFORMATION PROVIDED IN SCALED FORM; HOWEVER CONTRACTOR/SUPPLIERS SHOULD NOT SCALE PLANS OR DETAILS FOR DIMENSIONAL INFORMATION.

12. THE CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY SHORING AND BRACING FOR ALL STRUCTURAL ELEMENTS UNTIL THE ENTIRE STRUCTURAL SYSTEM IS COMPLETED. DESIGN OF ALL SHORING AND BRACING IS BY OTHERS AT NO ADDITIONAL COST TO THE OWNER.

13. ENGINEER SHALL NOT BE RESPONSIBLE FOR ACTIVITIES UNDER CONTROL OF THE CONTRACTOR SUCH AS CONSTRUCTION SITE SAFETY, MEANS, METHODS AND SEQUENCING OF CONSTRUCTION. ENGINEER SHALL NOT BE RESPONSIBLE FOR FABRICATION, ERECTION AND CONSTRUCTION REQUIREMENTS AS PRESCRIBED BY OSHA OR OTHER REGULATORY AGENCIES REGARDLESS OF INDICATIONS IN THESE DOCUMENTS.

14. NOTICE OF COPYRIGHT: THESE STRUCTURAL DRAWINGS ARE HEREBY COPYRIGHTED BY ARW ENGINEERS, ALL RIGHTS RESERVED. THESE DOCUMENTS DEFINE A STRUCTURE AND ARE INSTRUMENTS OF SERVICE, FOR ONE USE ONLY. REPRODUCTION AND DISTRIBUTION OF THESE DRAWINGS IS ONLY ALLOWED AS REQUIRED FOR REGULATORY AGENCIES AND FOR CONVEYANCE OF INFORMATION TO PARTIES INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. THESE DOCUMENTS SHALL NOT BE REPRODUCED OR COPIED, IN PART OR WHOLE BY ANY PARTY FOR USE IN PREPARATION OF SHOP DRAWINGS OR OTHER SUBMITTALS.

15. WHERE THE WORD "SHALL" OCCURS IN THESE DRAWINGS AND ANY ACCOMPANYING SPECIFICATIONS, IT IS CONSIDERED A MANDATORY OBLIGATION AND SYNONYMOUS WITH THE PHRASE "HAS DUTY TO".

B. STATEMENT OF SPECIAL INSPECTIONS AND SPECIAL INSPECTIONS

1. THE DESIGNATED SEISMIC/WIND SYSTEMS AND SEISMIC/WIND-FORCE-RESISTING SYSTEMS THAT ARE SUBJECT TO SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC SECTION 1705.11 AND 1705.12 ARE IDENTIFIED ON THESE DOCUMENTS WITH A CIRCLE “L”. ALL OTHER ITEMS REQUIRING SPECIAL INSPECTION ARE IDENTIFIED IN THE SPECIAL INSPECTION SCHEDULE ON SHEET S0.02.

2. SPECIAL INSPECTIONS AND TESTING ARE TO BE PROVIDED AS REQUIRED BY IBC SECTIONS 1704 THROUGH 1705 AND OTHER APPLICABLE SECTIONS OF THE IBC. THE TYPE AND FREQUENCY OF TESTING AND SPECIAL INSPECTIONS SHALL BE AS NOTED IN THE SPECIAL INSPECTION SCHEDULE, JOB SPECIFICATIONS, AND ACCORDANCE WITH IBC SECTION 110 AND CHAPTER 17. CONTRACTOR SHALL COORDINATE AND COOPERATE WITH REQUIRED INSPECTIONS.

3. ALL TESTING AND SPECIAL INSPECTION SHALL BE PROVIDED BY A QUALIFIED INDEPENDENT SPECIAL INSPECTION AGENCY IN ACCORDANCE WITH IBC 1704 AND AS OUTLINED IN THE JOB SPECIFICATIONS. REPORTS OF FINDINGS OR DISCREPANCIES SHALL BE NOTED AND FORWARDED TO THE CONTRACTOR, ARCHITECT, ENGINEERS, AND BUILDING OFFICIAL IN A TIMELY MANNER.

4. STRUCTURAL OBSERVATION VISITS SHALL BE PERFORMED BY A REPRESENTATIVE FROM ARW ENGINEERS IN ACCORDANCE WITH THE CONTRACT AS NEEDED TO OBSERVE THE CONSTRUCTION OF CRITICAL BUILDING ELEMENTS (I.E. FOOTINGS, BRACED FRAMES, MOMENT FRAMES, DRAG STRUTS AND THEIR CONNECTIONS, COLLECTORS, AND ROOF AND FLOOR DIAPHRAGMS). STRUCTURAL OBSERVATION REPORTS FOR EACH VISIT SHALL BE SENT DIRECTLY TO THE ARCHITECT FOR DISTRIBUTION TO THE CONTRACTOR AND BUILDING OFFICIAL. STRUCTURAL OBSERVATION VISITS SHALL NEITHER BE CONSTRUED AS SPECIAL INSPECTION NOR APPROVAL OF COMPLETED CONSTRUCTION.

5. IN ACCORDANCE WITH IBC 1704.4, THE CONTRACTOR SHALL SUBMIT A WRITTEN CONTRACTOR’S STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER. THE STATEMENT SHALL BE SUBMITTED PRIOR TO THE CONSTRUCTION OF ANY SEISMIC/WIND-FORCE-RESISTING SYSTEM, DESIGNATED SEISMIC/WIND SYSTEM, OR COMPONENT IDENTIFIED IN THESE DOCUMENTS WITH A CIRCLE “L”.

C. BASIS OF DESIGN

1. GOVERNING BUILDING CODE : INTERNATIONAL BUILDING CODE (IBC) 2018RISK CATEGORY : II

2. ROOF LOADSa. FLAT-ROOF SNOW LOAD, Pf : 30 PSF

1. GROUND SNOW LOAD, Pg : 43 PSF2. SNOW EXPOSURE FACTOR, Ce : 1.03. SNOW LOAD IMPORTANCE FACTOR, Is : 1.04. THERMAL FACTOR, Ct : 1.05. SLOPE FACTOR, CS : 1.06. SNOW DRIFT : SHOWN ON PLANS WHERE APPLICABLE.

b. LIVE LOAD = 20 PSFc. DEAD LOAD = 15 PSF

3. WIND DESIGNa. BASIC WIND SPEED (3 SECOND GUST) : 103 MPHb. WIND EXPOSURE : Cc. INTERNAL PRESSURE COEFFICIENT, GCPI : 0.18d. COMPONENT AND CLADDING DESIGN WIND PRESSURE SHALL BE AS REQUIRED PER ASCE 7-16.

4. SEISMIC DESIGN :a. SEISMIC IMPORTANCE FACTOR, IE : 1.0b. SITE CLASS : Dc. MAPPED SPECTRAL RESPONSE ACCELERATIONS : SS = 1.147 , S1 = 0.418d. SPECTRAL RESPONSE COEFFICIENTS : SDS = 0.918 , SD1 = 0.524e. SEISMIC DESIGN CATEGORY : Df. BASIC SEISMIC-FORCE-RESISTING SYSTEM : LIGHT-FRAME WOOD SHEAR WALLg. DESIGN BASE SHEAR : VN-S = 12.8k , VE-W = 12.8kh. SEISMIC RESPONSE COEFFICIENT, CS : 0.141i. RESPONSE MODIFICATION FACTOR, R : 6.5j. ANALYSIS PROCEDURE : STATIC, ELF

D. FOUNDATION

1. GENERALa. DESIGN SOIL PRESSURE : 1500 PSFb. ALL FOOTINGS SHALL BE PLACED ON MECHANICALLY COMPACTED FILL COMPACTED TO NOT LESS

THAN 95% OF MODIFIED PROCTOR DENSITY (ASTM D-1557).c. UNLESS NOTED OTHERWISE, ALL CONCRETE SLABS ON EARTH SHALL BEAR ON STRUCTURAL FILL

COMPACTED TO 90% OF MODIFIED PROCTOR DENSITY (ASTM D-1557).d. TOP OF FOOTING ELEVATIONS SHOWN ON THE FOOTING AND FOUNDATION PLAN ARE BASED ON

PRELIMINARY GRADING INFORMATION AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION. STEPS WHERE SHOWN ARE AT APPROXIMATE LOCATIONS. ACTUAL STEP LOCATIONS SHALL BE AT THE CONTRACTOR’S DISCRETION BASED UPON FIELD CONDITIONS. ALL EXTERIOR FOUNDATIONS SHALL BEAR A MINIMUM OF 30 INCHES BELOW LOWEST ADJACENT FINAL GRADE.

e. ALL WALLS (EXCEPT CANTILEVERED RETAINING WALLS) SHALL BE ADEQUATELY BRACED AGAINST LATERAL MOVEMENT PRIOR TO BACKFILLING. DESIGN AND ERECTION OF BRACING/SHORING SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. BRACING SHALL REMAIN IN PLACE UNTIL SUPPORTING STRUCTURAL ELEMENTS ARE IN PLACE AND HAVE ATTAINED FULL STRENGTH.

f. UNLESS NOTED OTHERWISE, ALL FOOTINGS AT COLUMNS SHALL BE CENTERED BELOW COLUMNS.g. UNLESS NOTED OTHERWISE, ALL FOOTINGS SHALL HAVE VERTICAL FACES FORMED WITH

STANDARD FORMING MATERIALS (WOOD, METAL, ETC.). WITH PRIOR APPROVAL OF ARCHITECT AND ENGINEER, CONCRETE FOR FOOTINGS CAN BE PLACED IN EXCAVATED SOIL “FORMS” PROVIDED THAT THE DIMENSIONS ARE INCREASED 3” ON ALL SIDE.

I. TIMBER

1. WOOD GRADES (UNLESS NOTED OTHERWISE)a. ALL FRAMING LUMBER SHALL BE DOUGLAS FIR/LARCH CLEARLY MARKED WITH A STAMP BY WWPA

APPROVED AGENCY AND SHALL BE GRADED AS FOLLOWS:1. HORIZONTAL MEMBERS: JOISTS & RAFTERS: NO. 2, BEAMS & STRINGERS: NO. 2.2. VERTICAL MEMBERS: POST & TRIMMERS: NO. 1, STUDS: NO. 2.

b. ALL FRAMING IN CONTACT WITH FOOTINGS, FOUNDATIONS OR SLABS ON GRADE SHALL BE PRESSURE TREATED OR TIMBERSTRAND LSL TREATED LUMBER WITH EQUIVALENT STRESS GRADES TO TYPICAL FRAMING MEMBERS.

2. SHEATHING SHALL BE APA RATED SHEATHING, EXPOSURE I, EXTERIOR GLUE AND PANEL INDEX RATING AS NOTED BELOW UNLESS NOTED OTHERWISE :

LOCATION THICKNESS PANEL INDEXWALLS : 15/32” 24/0ROOFS : 19/32” 32/16

3. INDIVIDUAL PIECES OF SHEATHING AT ROOF, FLOOR, AND SHEAR WALLS SHALL NOT BE SMALLER THAN 24” IN EITHER DIRECTION AND SHALL SPAN A MINIMUM OF TWO FRAMING SPACES, UNO.

4. CONNECTIONS, FASTENERS, AND ADHESIVEa. ALL BOLTS THRU WOOD SHALL BE ASTM A307 AND SHALL HAVE HARDENED WASHERS UNDER ASTM

A563 HEAVY HEX NUT AND BOLT HEADS.b. UNLESS NOTED OTHERWISE, 10d COMMON (0.148) NAILS SHALL BE USED TO FASTEN ALL PLYWOOD

FLOOR AND ROOF SHEATHING TO SUPPORTING TRUSSES, JOISTS, LEDGERS OR BLOCKING AS FOLLOWS:1. BOUNDARY NAILING “BN”: 4”O.C. AT ALL BEARING WALLS, SHEAR WALLS, BLOCKING, AND

WHERE OTHERWISE INDICATED IN THE STRUCTURAL DRAWINGS.2. PANEL EDGE NAILING “EN”: 6”O.C. AT ALL OTHER PLYWOOD PANEL EDGES.3. PANEL FIELD NAILING “FN”: 12”O.C. AT INTERIOR SUPPORTS IN FIELD OF PANEL.

c. UNLESS NOTED OTHERWISE IN THE WOOD SHEAR WALL SCHEDULE ON SHEET S0.02, 10d COMMON (0.148) NAILS SHALL BE USED TO FASTEN ALL PLYWOOD SHEAR WALL SHEATHING TO STUDS AND BLOCKING AS FOLLOWS:1. PANEL EDGE NAILING “EN”: 6”O.C.2. PANEL FIELD NAILING “FN”: 12”O.C. AT INTERIOR SUPPORTS IN FIELD OF PANEL.

d. NAILS SHALL BE GALVANIZED OR STAINLESS STEEL AT EXPOSED LOCATIONS OR IN TREATED WOOD (SEE NOTE BELOW FOR FASTENERS CONNECTED TO OR IN CONTACT WITH TREATED WOOD). THE HEAD OF ALL NAILS SHALL BE DRIVEN FLUSH WITH THE SURFACE OF THE SHEATHING.

e. UNLESS NOTED OTHERWISE, ALL NAILS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES :COMMON SHANK HEAD LENGTH MIN. PENETRATIONNAIL SIZE DIAMETER DIAMETER INTO SUPPORT MEMBER6d 0.113” 0.266” 2” 1.25”8d 0.131” 0.281” 2-1/2” 1.375”10d 0.148” 0.312” 3” 1.50”12d 0.148” 0.312” 3-1/4” 1.50”16d 0.162” 0.344” 3-1/2” 1.62”

f. ALL FRAMING ANCHORS, POST CAPS, HOLD DOWNS, COLUMN BASES ETC. TO BE PROVIDED BY SIMPSON OR APPROVED EQUAL AND SHALL BE ATTACHED IN ACCORDANCE WITH MANUFACTURER’S PUBLISHED DATA, UNLESS NOTED OTHERWISE.

g. UNLESS NOTED OTHERWISE, ALL WALL BOTTOM PLATES TO BE ANCHORED TO FOUNDATIONS OR FOOTINGS WITH 3/4” DIAMETER ANCHOR BOLTS AT 32”O.C. WITH 8” MINIMUM EMBEDMENT. THERE SHALL BE A MINIMUM OF (2) ANCHOR BOLTS PER PLATE WITH ONE BOLT LOCATED NOT MORE THAN 12” AND NOT LESS THAN 4” FROM EACH END OF EACH PIECE.

h. WALL BOTTOM PLATES AT SHEAR WALLS SHALL INCLUDE 1/4” x 3” x 3” STEEL PLATE WASHERS BETWEEN THE SILL PLATE AND NUT OF THE ANCHOR BOLT. THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH UP TO 3/16” LARGER THAN THE BOLT DIAMETER AND SLOT LENGTH NOT TO EXCEED 1-3/4”, PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. THE PLATE WASHER SHALL EXTEND TO WITHIN ½” OF THE EDGE OF THE BOTTOM PLATE ON THE SHEATHED SIDE.

i. FASTENERS CONNECTED TO OR IN CONTACT WITH PRESERVATIVE-TREATED AND/OR FIRE-RETARDANT-TREATED WOOD (EXCEPT FOR TIMBERSTRAND LSL TREATED LUMBER AND BORATE BASED TREATMENTS) SHALL BE OF G-185 HOT-DIP GALVANIZED STEEL OR 304 OR 316 STAINLESS STEEL. STAINLESS STEEL AND GALVANIZED STEEL SHALL NEVER BE USED IN CONTACT WITH EACH OTHER.

j. EXCEPT WHERE NOTED OTHERWISE, THE NUMBER AND SIZE OF NAILS CONNECTING WOOD MEMBERS SHALL NOT BE LESS THAN THAT SET FORTH IN IBC TABLE 2304.10.1. CONNECTIONS FOR MULTIPLE PIECES OF ENGINEERED LUMBER PIECES SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS.

5. ALL WOOD TRUSSED RAFTERS SHALL BE FABRICATED IN COMPLIANCE WITH THE RESEARCH COMMITTEE RECOMMENDATIONS OF THE ICC FOR THE CONNECTOR PLATES USED. SUBMIT DESIGN CALCULATIONS WITH ENGINEERS SEAL FOR REVIEW WITH SHOP DRAWINGS. PROVIDE CALCULATIONS AND DETAILS FOR ALL TRUSS TO TRUSS CONNECTIONS INCLUDING CONNECTION HARDWARE. ALL NECESSARY TRUSS BRIDGING AND CONNECTION DESIGN OF TRUSS BRIDGING SHALL BE PROVIDED BY THE TRUSS DESIGNER AND SHALL BE INCLUDED IN THE DESIGN CALCULATIONS FOR REVIEW.

6. INSTALLATION OF ALL METAL-PLATE-CONNECTED WOOD TRUSSES SHALL COMPLY WITH THE FOLLOWING STANDARDS :a. ANSI/TPI 1 “NATIONAL DESIGN STANDARD FOR METAL-PLATE-CONNECTED WOOD TRUSSES”.b. TPI HIB “COMMENTARY AND RECOMMENDATIONS FOR HANDLING INSTALLING & BRACING METAL-

PLATE-CONNECTED WOOD TRUSSES”.c. TPI DSB “RECOMMENDED DESIGN SPECIFICATION FOR TEMPORARY BRACING OF METAL-PLATE-

CONNECTED WOOD TRUSSES”.7. UNLESS NOTED OTHERWISE, ALL ROOF SHEATHING AND WALL SHEATHING AT SHEAR WALLS SHALL

HAVE SOLID BLOCKING AT ALL PANEL EDGES.8. PROVIDE SOLID 2” (NOMINAL) FULL DEPTH BLOCKING AT ENDS AND SUPPORT LOCATIONS FOR ALL

JOISTS AND RAFTERS. BLOCKING SHALL BE ATTACHED TO SUPPORT FRAMING WITH A MINIMUM OF (1) SIMPSON A35 FRAMING ANCHOR BETWEEN JOISTS UNLESS NOTED OTHERWISE.

9. UNLESS NOTED OTHERWISE, ALL BEARING WALLS SHALL BE 2x6 SPACED AT 16 “O.C. BLOCK ALL NON-SHEATHED BEARING WALLS AT 4’-0”O.C.

10. VERIFY THE STUD SPACING WITH THE ANCHOR BOLT LAY-OUT. WHERE STUDS INTERFERE WITH ANCHOR BOLTS, PROVIDE AN ADDITIONAL FULL-HEIGHT STUD TO ENSURE THAT THE FULL CROSS-SECTIONAL AREA OF THE STUD IS IN CONTACT WITH THE SILL PLATE.

11. UNLESS NOTED OTHERWISE, ALL EXTERIOR WALLS AND SHEAR WALLS SHALL HAVE DOUBLE 2X TOP PLATES THAT ARE SPLICED TOGETHER WITH A MINIMUM OF 48” OF OVERLAP AND SHALL BE CONNECTED TOGETHER WITH A MINIMUM OF (28) 10d COMMON NAILS EACH SIDE OF THE SPLICE. OUTSIDE OF THESE SPLICE LOCATIONS, TOP PLATES SHALL BE NAILED TOGETHER WITH 10d NAILS AT 12” O.C.

12. UNLESS NOTED OTHERWISE, ALL HORIZONTAL FRAMING MEMBERS SHALL BE INSTALLED WITH THE NATURAL CROWN UP.

J. STRUCTURAL DELEGATED DESIGNS AND DEFERRED SUBMITTALS

1. STRUCTURAL DELEGATED DESIGNS AND SUBSEQUENT DEFERRED SUBMITTALS ARE FOR ELEMENTS, PARTS, OR PORTIONS OF THE OVERALL STRUCTURAL SYSTEM THAT ARE INDICATED OR REFERRED TO ON THESE DRAWINGS AND THAT ARE CRITICAL TO THE PERFORMANCE OF THE OVERALL STRUCTURAL SYSTEM. DESIGN CRITERIA HAS BEEN PROVIDED FOR THESE ITEMS IN THE STRUCTURAL NOTES, PLANS, AND DETAILS.

2. STRUCTURAL DEFERRED SUBMITTALS ARE COMPLETE PACKAGES TO BE SUBMITTED FOR REVIEW THAT INCLUDE DRAWINGS AND CALCULATIONS FOR ALL DELEGATED DESIGN ITEMS AND THEIR CONNECTIONS. DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF THE DESIGN PROFESSIONAL RESPONSIBLE FOR THEIR DESIGN.

3. ARW ENGINEERS WILL REVIEW STRUCTURAL DEFERRED SUBMITTALS TO VERIFY DESIGN CRITERIA IS COMPLIANT WITH THE APPROVED CONSTRUCTION DOCUMENTS.

4. STRUCTURAL DELEGATED DESIGN COMPONENTS SHALL NOT BE INSTALLED UNTIL APPROVED BY THE BUILDING OFFICIAL.

5. STRUCTURAL DELEGATED DESIGN ITEMS REQUIRING DEFERRED SUBMITTALS INCLUDE, BUT ARE NOT LIMITED TO :a. PRE-MANUFACTURED WOOD TRUSSES, BLOCKING, BRIDGING, BRIDGING CONNECTIONS, FASCIA,

TRUSS HANGERS, AND RELATED COMPONENTS.

K. NON-STRUCTURAL DELEGATED DESIGNS AND DEFERRED SUBMITTALS

1. NON-STRUCTURAL DELEGATED DESIGNS AND SUBSEQUENT DEFERRED SUBMITTALS ARE FOR ITEMS NOT INCLUDED IN THE STRUCTURAL DELEGATED DESIGN SECTION. THESE ARE ITEMS THAT ARE NOT CRITICAL TO THE OVERALL PERFORMANCE OF THE STRUCTURAL SYSTEM BUT THAT IMPART LOADS AND FORCES TO THE STRUCTURAL SYSTEM.

2. NON-STRUCTURAL DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF THE DESIGN PROFESSIONAL RESPONSIBLE FOR THE DESIGN.

3. ARW ENGINEERS WILL REVIEW NON-STRUCTURAL DEFERRED SUBMITTALS TO VERIFY DESIGN CRITERIA IS COMPLIANT WITH THE APPROVED CONSTRUCTION DOCUMENTS.

4. IF THE STRUCTURAL DRAWINGS INCLUDE LOADS TO ACCOMMODATE NON-STRUCTURAL ELEMENTS, THE CONTRACTOR SHALL SUBMIT DOCUMENTATION INDICATING THAT THE NON-STRUCTURAL ELEMENTS COMPLY WITH THE LOADING CRITERIA PROVIDED HEREIN. SUCH DOCUMENTATION SHALL BEAR THE STAMP AND SIGNATURE OF THE DESIGN PROFESSIONAL RESPONSIBLE FOR THE DESIGN.

5. IF THE NON-STRUCTURAL DEFERRED SUBMITTAL INDICATES THAT THE ELEMENT WILL IMPART FORCES IN EXCESS OF THOSE INDICATED ON THE STRUCTURAL DRAWINGS, THE CONTRACTOR SHALL SUBMIT A DETAILED GRAPHICAL REPRESENTATION OF THOSE DESIGN LOADS, INCLUDING MAGNITUDE, AND LOCATION. THE GRAPHIC SHALL BE ACCOMPANIED BY DOCUMENTATION INDICATING THAT THE NON-STRUCTURAL ELEMENT DESIGN COMPLIES WITH THE LOADING CRITERIA PROVIDED HEREIN. THE LETTER SHALL BEAR THE STAMP AND SIGNATURE OF THE DESIGN PROFESSIONAL RESPONSIBLE FOR THE DESIGN.

6. NON-STRUCTURAL DELEGATED DESIGN ITEMS REQUIRING DEFERRED SUBMITTALS SHALL INCLUDE, BUT ARE NOT LIMITED TO :a. SEISMIC BRACING OF ALL ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

WHERE REQUIRED BY THE MOST RECENT VERSION OF ASCE 7 AND THE PROJECT CONTRACT DOCUMENTS.

L. EXISTING BUILDING NOTES

1. ARW ENGINEERS EXPRESSLY DISCLAIMS RESPONSIBILITY FOR ANY PORTION OF THE EXISTING BUILDING NOT SPECIFICALLY ADDRESSED IN THESE DRAWINGS.

2. DRAWINGS AND DETAILS HAVE BEEN PREPARED TO REFLECT THE EXISTING CONDITIONS AND CONFIGURATIONS OF STRUCTURAL ELEMENTS. HOWEVER, THE CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS AND ALERTING THE ENGINEER OF ANY DISCREPANCIES FOUND PRIOR TO FABRICATING OR INSTALLING STRUCTURAL ELEMENTS.

3. THE CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THAT THE BUILDING AND ELEMENTS WITHIN THE BUILDING REMAIN STABLE UNTIL CONSTRUCTION IS COMPLETE. AT NO ADDITIONAL COST TO THE OWNER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING SHORING OR OTHER TEMPORARY SUPPORT OF STRUCTURAL MEMBERS UNTIL THE FINAL CONFIGURATION HAS BEEN COMPLETED.

E. CONCRETE

1. ALL CONCRETE MIX DESIGNS SHALL COMPLY WITH THE REQUIREMENTS LISTED BELOW :a. FOOTINGS, GRADE BEAMS, FOUNDATION WALLS :

1. WHERE THE TOP OF THE ELEMENT IS EXPOSED OR IS LOCATED WITHIN 30” OF THE LOWEST ADJACENT GRADE (EXPOSURE CATEGORY F2) :a. 28 DAY COMPRESSIVE STRENGTH : 4500 PSIb. MAXIMUM W/C RATIO : 0.45c. MAXIMUM AGGREGATE SIZE : 1”d. AIR CONTENT : 4.5% +/- 1.5%

2. WHERE THE TOP OF THE ELEMENT IS NOT EXPOSED OR IS NOT LOCATED WITHIN 30” OF THE LOWEST ADJACENT GRADE (EXPOSURE CATEGORY F0) :a. 28 DAY COMPRESSIVE STRENGTH : 3000 PSI

b. INTERIOR SLABS ON GRADE (EXPOSURE CATEGORY F0) :1. 28 DAY COMPRESSIVE STRENGTH : 3000 PSI

c. EXTERIOR SLABS (DOCKS, ETC.) (EXPOSURE CATEGORY F2) :1. 28 DAY COMPRESSIVE STRENGTH : 4500 PSI2. MAXIMUM W/C RATIO : 0.453. MAXIMUM AGGREGATE SIZE : 1”4. MINIMUM AIR CONTENT : 4.5% +/- 1.5%

2. WATER USED IN MIXING CONCRETE SHALL CONFORM TO ASTM C1602.3. NO PIPES, DUCTS, SLEEVES, ETC. SHALL BE PLACED IN STRUCTURAL CONCRETE UNLESS

SPECIFICALLY DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. NO ALUMINUM PRODUCTS SHALL BE EMBEDDED IN CONCRETE. PENETRATIONS THRU STRUCTURAL CONCRETE ELEMENTS MUST BE APPROVED BY THE ENGINEER AND SHALL BE BUILT INTO THE ELEMENT PRIOR TO CONCRETE PLACEMENT.

4. REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES, ORNAMENTS, ETC. TO BE CAST IN TO CONCRETE, AND FOR EXTENT AND LOCATION OF DEPRESSIONS, CURBS, RAMPS, ETC.

5. UNLESS NOTED OTHERWISE, MINIMUM REINFORCING IN ALL CONCRETE FOUNDATION WALLS SHALL BE AS FOLLOWS:

TOP &THICKNESS BOTTOM BARS VERTICAL HORIZONTAL6” (1) #5 #4 AT 18”O.C. #4 AT 16”O.C.8” (2) #5 #4 AT 18”O.C. #4 AT 12”O.C.10” (2) #5 #4 AT 12”O.C. #5 AT 12”O.C.12” (2) #5 #4 AT 18”O.C. EA FACE #4 AT 16”O.C. EA FACE

6. UNLESS NOTED OTHERWISE, CONCRETE SLABS ON EARTH SHALL BE UNREINFORCED. 7. UNLESS NOTED OTHERWISE, FOR NON-DETAILED OPENINGS IN CONCRETE WALLS LARGER THAN 12”

AND SMALLER THAN 24” IN ANY DIRECTION ADD (2) #5 BARS ON ALL SIDES IN ADDITION TO REGULAR WALL REINFORCING AND EXTEND 24” EACH WAY BEYOND OPENING. IF 24” IS NOT AVAILABLE ON EVERY SIDE, NOTIFY STRUCTURAL ENGINEER FOR FURTHER DIRECTION. OPENINGS SHALL HAVE A MINIMUM OF 12" OF CONCRETE ABOVE THE OPENING, TYP.

8. CONSTRUCTION JOINTS NOT SHOWN ON THE PLANS SHALL BE MADE AND LOCATED SO AS TO NOT IMPAIR THE STRENGTH OF THE STRUCTURE AND AS APPROVED BY THE STRUCTURAL ENGINEER. PROVIDE 2 X 4 (SHAPED) KEYWAY IN ALL VERTICAL AND HORIZONTAL JOINTS UNLESS NOTED OR DETAILED OTHERWISE. ALL STEEL REINFORCING SHALL BE CONTINUOUS THROUGH COLD JOINTS UNLESS NOTED OTHERWISE. SEE TYPICAL DETAILS FOR COLD/CONSTRUCTION JOINTS FOR SLABS ON GRADE.

9. WHERE NEW CONCRETE IS PLACED AGAINST PREVIOUSLY HARDENED CONCRETE, THE JOINT SHALL BE CLEAN AND FREE OF LAITANCE. IMMEDIATELY BEFORE NEW CONCRETE IS PLACED, CONSTRUCTION JOINTS SHALL BE PREWETTED AND STANDING WATER REMOVED.

F. ANCHOR BOLTS/EMBEDDED BOLTS

1. ALL ANCHOR BOLTS SHALL HAVE ASTM A-563 HEAVY HEX NUT AND ASTM F-436 WASHERS AT STANDARD OR OVERSIZED HOLES PER AISC SPECIFICATION TABLE J3.3. WHERE HOLE SIZES DO NOT COMPLY WITH THE LIMITATIONS FOR OVERSIZED HOLES THE STRUCTURAL ENGINEER SHALL BE NOTIFIED TO DETERMINE STEEL PLATE WASHER REQUIREMENTS. ANCHOR BOLTS SHALL COMPLY WITH THE FOLLOWING :a. AT WOOD STUD WALLS - ASTM A-307 GRADE HEADED BOLTS. ANCHOR BOLTS IN TREATED LUMBER

SHALL BE GALVANIZED OR STAINLESS STEEL. SEE TIMBER NOTES FOR MORE INFORMATION.b. AT ALL OTHER ANCHOR BOLTS (UNLESS NOTED OTHERWISE) - ASTM F1554 GRADE 36 HEADED

BOLTS. (ASTM A36 THREADED ROD MAY BE USED WITH DOUBLE NUT AND WASHER.)2. SEE TYPICAL ANCHOR BOLT DETAIL FOR DEFINITIONS OF EMBEDMENT LENGTH, ETC.3. FURNISH TEMPLATES AND OTHER DEVICES AS NECESSARY FOR PRESETTING ALL BOLTS PRIOR TO

PLACING CONCRETE AND/OR GROUT.4. IF THREADED RODS ARE USED AS PERMITTED ABOVE, THEY SHALL BE CLEAR OF SOIL AND DIRT.5. WHERE REQUIRED FOR ERECTION, HOLES LARGER THAN OVERSIZED MAY BE PERMITTED WITH THE

USE OF STEEL PLATE WASHERS AT THE DISCRETION OF THE STRUCTURAL ENGINEER.

G. ADHESIVE/MECHANICAL ANCHORS

1. WITHOUT WRITTEN APPROVAL OF THE ENGINEER, CONTRACTOR SHALL NOT SUBSTITUTE POST-INSTALLED ANCHORS WHERE CAST-IN-PLACE ANCHORS ARE SPECIFIED IN THE DRAWINGS.

2. WHERE STRUCTURAL DETAILS SPECIFY SPECIFIC BRANDS AND/OR TYPES OF ADHESIVES OR ANCHORS, SUBSTITUTIONS OF OTHER BRANDS AND/OR TYPES IS NOT ALLOWED, WITHOUT WRITTEN APPROVAL OF THE ENGINEER.

3. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS SHALL BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. SUBSTITUTION REQUESTS SHALL INCLUDE AN ICC ESR OR IAPMO REPORT AND SUPPORTING CALCULATIONS INDICATING COMPLIANCE WITH DESIGN INTENT.

4. ALL ADHESIVE/MECHANICAL ANCHORS SHALL BE INSTALLED, INCLUDING HOLE DRILLING AND PREPARATION, IN ACCORDANCE WITH AN APPROVED INDEPENDENT EVALUATION REPORT (ICC-ES, IAPMO, OR APPROVED EQUAL), AS INDICATED BELOW, AND IN ACCORDANCE WITH ALL MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS (MPII).

5. ADHESIVE ANCHORS SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF 21 DAYS AT TIME OF ANCHOR INSTALLATION. ADHESIVE ANCHORS SHALL NOT BE FULLY LOADED UNTIL CONCRETE HAS REACHED DESIGN STRENGTH.

6. UNLESS APPROVED BY THE ENGINEER OF RECORD, CONCRETE AND DRILLED ANCHOR HOLES SHALL BE DRY AND FREE OF WATER FOR 24 HOURS PRIOR TO ADHESIVE INSTALLATION. CONTACT THE ENGINEER OF RECORD FOR GUIDANCE IF THE CONTRACTOR CHOOSES TO INSTALL IN WET OR DAMP HOLES.

7. CONCRETE TEMPERATURE AT THE TIME OF INSTALLATION SHALL BE MONITORED BY THE CONTRACTOR. CONTRACTOR SHALL COMPLY WITH ALL MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII) RELATIVE TO SUBSTRATE TEMPERATURE.

8. INSTALLATION OF ADHESIVE ANCHORS HORIZONTALLY OR UPWARDLY INCLINED TO SUPPORT SUSTAINED TENSION LOADS SHALL BE PERFORMED BY PERSONNEL CERTIFIED BY AN APPLICABLE CERTIFICATION PROGRAM. CERTIFICATION SHALL INCLUDE WRITTEN AND PERFORMANCE TESTS IN ACCORDANCE WITH THE ACI/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM, OR EQUIVALENT IN ACCORDANCE WITH ACI 318-11 D.9.2.2. PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. CONTINUOUS SPECIAL INSPECTION SHALL BE PROVIDED FOR THESE ANCHORS.

9. UNLESS NOTED OTHERWISE, ALL ADHESIVE ANCHORS INTO CONCRETE SHALL BE:a. HILTI HIT-RE 500V3 (ESR-3814), OR HILTI HIT-HY 200-A (ESR-3187).b. SIMPSON SET-3G (ESR-4057), OR AT-XP (ER-0263). c. DEWALT PURE 110+ (ESR-3298), OR AC200+ GOLD (ESR-4027-COLD WEATHER).

10. UNLESS NOTED OTHER WISE, ALL MECHANICAL ANCHORS INTO CONCRETE SHALL BE:a. HILTI KWIK BOLT TZ (ESR-1917). b. SIMPSON STRONG-BOLT 2 (ESR-3037).

11. UNLESS NOTED OTHERWISE, ALL SCREW ANCHORS INTO CONCRETE SHALL BE:a. SIMPSON TITEN HD (ESR-2713).b. DEWALT SCREWBOLT+ (ESR-2526).c. HILTI KWIK HUS-EZ (ESR-3027).

12. THE TESTING LABORATORY WILL PERFORM VISUAL INSPECTION OF ANCHORS AND DOWELS AS SPECIFIED IN THE SPECIAL INSPECTION SCHEDULE AND THE APPROVED INDEPENDENT EVALUATION REPORT. TENSION TESTING CAN BE REQUIRED AT THE DIRECTION OF THE STRUCTURAL ENGINEER OF RECORD OR THE SPECIAL INSPECTOR.

13. IF REINFORCEMENT IS ENCOUNTERED DURING DRILLING, ABANDON THAT HOLE AND SHIFT THE ANCHOR LOCATION TO AVOID THE REINFORCEMENT. PROVIDE A MINIMUM SPACE OF (2) ANCHOR HOLE DIAMETERS OR 1 INCH, WHICH EVER IS LARGER, OF SOUND CONCRETE/MASONRY BETWEEN THE ANCHOR AND THE ABANDONED HOLE. FILL THE ABANDONED HOLE WITH NON-SHRINK GROUT. AT CONTRACTORS OPTION, LOCATE EXISTING REINFORCEMENT PRIOR TO DRILLING/CORING. IF THE ANCHOR OR DOWEL CANNOT BE SHIFTED AS NOTED ABOVE, THE ENGINEER WILL DETERMINE A NEW LOCATION.

14. LOCATE REINFORCEMENT AND CONFIRM FINAL ANCHOR LOCATIONS PRIOR TO FABRICATING PLATES, MEMBERS, OR OTHER STEEL ASSEMBLIES ATTACHED WITH MECHANICAL ANCHORS.

H. REINFORCING STEEL

1. REINFORCING BAR STRENGTH REQUIREMENTS:a. ALL REINFORCING BARS SHALL CONFORM TO ASTM STANDARD A-615 GRADE 60 AND ALL WELDED

WIRE FABRIC SHALL CONFORM TO ASTM STANDARD A-1064 AND SHALL BE SUPPLIED IN FLAT SHEETS. ADEQUATELY TIE AND SUPPORT ALL REINFORCING STEEL AS SPECIFIED BY ACI 117, TO MAINTAIN EXACT REQUIRED POSITION.

2. ALL REINFORCING STEEL SHALL BE TIED IN PLACE AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET STABBING OF ANY REINFORCING STEEL IS NOT PERMITTED, UNLESS SPECIFICALLY DETAILED OTHERWISE OR APPROVED BY THE ENGINEER.

3. ALL FIELD BENT DOWELS SHALL BE GRADE 40 WITH SPACING INDICATED REDUCED BY 1/3.4. UNLESS NOTED OTHERWISE, REINFORCEMENT SHALL HAVE THE FOLLOWING CONCRETE COVERAGE :

a. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ….. 3”b. EXPOSED TO EARTH OR WEATHER :

1. #6 & LARGER ….. 2”2. #5 & SMALLER …..1-1/2”

c. NOT EXPOSED TO WEATHER OR EARTH :1. SLABS, WALLS, JOISTS, #11 & SMALLER ….. 3/4”2. BEAMS, COLUMNS: MAIN REINFORCING OR TIES ….. 1-1/2”

d. SLAB ON GRADE :1. PLACE REINFORCING AT CENTER OF SLAB UNLESS INDICATED OTHERWISE.

5. EXCEPT WHERE NOTED ON PLANS OR DETAILS CONTINUOUS REINFORCEMENT SHALL BE SPLICED AT POINTS OF MINIMUM STRESS BY LAPPING PER THE REBAR LAP SCHEDULE.

6. REINFORCING STEEL MAY BE SPLICED WITH MECHANICAL COUPLERS THAT HAVE A TENSION CAPACITY OF AT LEAST 125% OF THE STRENGTH OF THE BAR. MECHANICAL COUPLERS SHALL BE A POSITIVE CONNECTING TYPE COUPLER, AND SHALL BE INSTALLED IN ACCORDANCE WITH AN APPROVED ICC RESEARCH REPORT. WHERE THESE ARE USED, SPLICES ON ADJACENT BARS SHALL BE STAGGERED AT LEAST 24 INCHES ALONG THE LENGTH OF THE BARS.

7. ALL VERTICAL REINFORCING IN STRUCTURAL ELEMENTS ABOVE SHALL BE SPLICED WITH MATCHING DOWELS EMBEDDED WITHIN THE FOOTINGS OR STRUCTURE BELOW. SPLICE LENGTHS SHALL COMPLY WITH REBAR LAP SCHEDULE. DOWELS INTO FOOTINGS SHALL TERMINATE WITH A STANDARD HOOK, AND SHALL EXTEND TO WITHIN 4” OF THE BOTTOM OF THE FOOTING, BUT NEED NOT EXTEND MORE THAN 20” INTO FOOTING. FOR MASONRY CONSTRUCTION SEE STRUCTURAL NOTE P.6.A.

8. DO NOT WELD REINFORCING EXCEPT AS NOTED ON PLANS, WHERE REINFORCING IS WELDED, USE ASTM A-706 REINFORCING.

9. REINFORCING BARS, TIES, AND TENDONS SHALL BE SUPPORTED BY NYLON CONES, PLASTIC-COATED TIE-WIRES, OR PLASTIC-COATED CHAIRS. REINFORCING IN FOOTINGS IS PERMITTED TO BE SUPPORTED ON CONCRETE DOBIES.

10. UNLESS NOTED OTHERWISE, HOOKS, STIRRUPS, TIES, AND OTHER BENDS IN REINFORCING STEEL SHALL MEET THE STANDARDS SET FORTH IN ACI 318/318R-14. UNLESS OTHERWISE PERMITTED BY THE ENGINEER, ALL REINFORCEMENT SHALL BE BENT COLD. REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT, EXCEPT AS SHOWN ON THESE DRAWINGS OR OTHERWISE PERMITTED BY THE ENGINEER.

11. UNLESS SPECIFICALLY NOTED AND/OR DETAILED IN THE STRUCTURAL DRAWINGS CONDUIT SHALL NOT BE IN CONTACT WITH REINFORCING STEEL.

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

ARW:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF

FA

CIL

ITIE

S C

ON

ST

RU

CT

ION

AN

D M

AN

AG

EM

EN

T

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

HKS: 22564.000

C:\

Users

\am

monh\D

ocum

ents

\S-1

9467-C

am

p W

illia

ms

4141-2

019_ja

sonr@

arw

engin

eers

.com

.rvt

2/1

4/2

020 1

1:0

8:3

6 A

M

S0.01

STRUCTURAL NOTES

14 FEBRUARY 2020

19467

CONSTRUCTION

DOCUMENTS

Structural Sheet Index

SHEETNUMBER SHEET NAME

S0.01 STRUCTURAL NOTES

S0.02 SCHEDULES

S1.01 FOOTING, FOUNDATION & ROOF FRAMING PLAN

S2.01 DETAILS

S2.02 DETAILS

S4.01 SCHEMATIC REFERENCE

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

Page 15: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

S S

LEGEND OF SYMBOLS AND ABBREVIATIONS

AB = ANCHOR BOLTABV = ABOVEARCH = ARCHITECTBLW = BELOWBN = BOUNDARY NAILINGBRB = BUCKLING RESTRAINED BRACEBRBF = BUCKLING RESTRAINED BRACE FRAMECJP = COMPLETE JOINT PENETRATIONCL = CENTERLINECMU = CONCRETE MASONRY UNITCOL = COLUMNCONC = CONCRETECP = CONCRETE PIERDC = DEMAND CRITICALDIA / Ø = DIAMETERDBA = DEFORMED BAR ANCHORDBE = DECK BEARING ELEVATIONELEV = ELEVATIONEN = EDGE NAILINGEOD = EDGE OF DECKFDN = FOUNDATIONFTG = FOOTINGFFE = FINISHED FLOOR ELEVATIONGB = CONCRETE GRADE BEAMHSA = HEADED STUD ANCHORJBE = JOIST BEARING ELEVATIONKB = KICKER BRACEMAX = MAXIMUMMB = MASONRY BEAMMC = MASONRY COLUMNMECH = MECHANICALMEZZ = MEZZANINEMIN = MINIMUMMJ = MASONRY JAMBMW = MASONRY WALLNS, FS = NEAR SIDE, FAR SIDEOAE = OR APPROVED EQUALOPP = OPPOSITEPAF = POWDER ACTUATED FASTENERPL = PLATEREINF = REINFORCINGREQ'D = REQUIREDSIM = SIMILARSSH = STEEL STUD HEADERSSJ = STEEL STUD JAMBSSS = STEEL STUD SILLSSW = STEEL STUD WALLTOB = TOP OF BEAM ELEVATIONTOC = TOP OF CONCRETE SLABTOF = TOP OF FOOTINGTOG = TOP OF GIRDER ELEVATIONTOM = TOP OF MASONRYTOS = TOP OF STEEL ELEVATIONTYP = TYPICALUNO = UNLESS NOTED OTHERWISE

CONCRETE BEAM

FOOTING STEP

TOP OF FOUNDATION WALL OR COLUMN PIER ELEV.

SHEET NUMBER

TOP OF FOOTING ELEV.

SECTION MARK

FOOTING MARK

ITEMS, DETAILS, & SYSTEMS WHICH ARE PART OF THE LATERAL FORCE RESISTING SYSTEM.

MOMENT RESISTING CONNECTIONS -SEE DETAIL

L

ELEVATION

MOMENT RESISTING CANTILEVER CONNECTIONS - SEE DETAIL

KICKER BRACEKB

SHEAR WALL - SEE SCHEDULE

MIN. LENGTH OF SHEAR WALL

DEPRESS FDN./WALL AND POUR FLOOR SLAB OVER AT CONCRETE FOUNDATION WALL

HD - SIMPSON HOLDOWN SIZE POST -SIZE OF END POST CONNECTED TO HOLDOWN "A" - PLAN CONFIGURATION AT HOLDOWN AT FOUNDATION

"A"

POSTH

D

TYP. FOOTING SECTIONTYP. FOOTING SECTION

W/ TOP & BOTTOM REINF.

THICKWIDTHMARK LENGTHLENGTHWISE REINF.

NO. SIZE NO. SIZE SPA.

CROSSWISE REINF.REMARKS

FOOTING SCHEDULE

FC2 2'-0" CONT. 12" (2) #5 -- -- --

TYPICAL FOOTING REINFORCING

3" CLEAR EQ. EQ. EQ. 3" CLEAR 3" CLEAR EQ. EQ. EQ. 3" CLEAR

3" CLEAR

2" CLEAR

3" CLEAR

JA

DIMENSION OF STANDARD90° HOOKS, ALL GRADES

DIMENSION OF STANDARD 180°HOOKS, ALL GRADESBAR SIZE

A

D = 6db FOR #3 THROUGH #8D = 8db FOR #9 THROUGH #11C = FOR BARS IN CMU:#6 AND LARGER, PROVIDE 12db

FROM POINT OF TANGENCY#5 AND SMALLER, PROVIDE 6db

FROM POINT OF TANGENCY(2 1/2" MINIMUM)

DETAILINGDIMENSIONS

D

D = 6db FOR #3 THROUGH #8D = 8db FOR #9 THROUGH #11

HOOK A

4 db OR 2 1/2" MIN.

180°

JD

STANDARD HOOK & BEND SCHEDULE

#3 5" 3" 6"

#4 6" 4" 8"

#5 7" 5" 10"

#6 8" 6" 1'-0"

#7 10" 7" 1'-2"

#8 11" 8" 1'-4"

#9 1'-3" 11 3/4" 1'-7"

#10 1'-5" 1'-1 1/4" 1'-10"

#11 1'-7" 1'-2 3/4" 2'-0"

AJ

DETAILINGDIMENSIONS

DETAILINGDIMENSIONS

D

C

D = 4db FOR #3 THROUGH #5D = 6db FOR #6 THROUGH #8D = 8db FOR #9 THROUGH #11

6db OR 2 1/2" MIN.FROM POINT OF

TANGENCY

NOTE: db = BAR DIAMETER

135°

90°

ESTABLISHED PER 2018 IBC SECTION 110 AND CHAPTER 17

ITEM

GENERAL SPECIAL INSPECTION NOTES :

PERIODIC3CONTINUOUS3 REFERENCE COMMENTS

SEE IBC TABLE 1705.3 - REF. NOTE C1

REFERENCE NOTE C4

REFERENCE NOTE C5

REFERENCE NOTES P1 & P2

REFERENCE NOTE C3

REFERENCE NOTE W1

REFERENCE NOTE F1

REFERENCE NOTE F1

REFERENCE NOTE F1

REFERENCE NOTE F2

REFERENCE NOTE W2

REFERENCE NOTE F1

REFERENCE NOTE F2

EPOXY / EXPANSION ANCHOR PLACEMENT

VERIFICATION OF IN-SITU STRENGTH

CURING TEMPERATURE / TECHNIQUES

CONCRETE PLACEMENT / SAMPLING

VERIFYING REQUIRED DESIGN MIX

EMBEDDED BOLTS & PLATES

REINFORCING STEEL PLACEMENT

HIGH LOAD DIAPHRAGMS (ROOF / FLOOR)

PROPERLY PREPARED SITE AND SUB-GRADE PRIOR TO FILL.

VERIFY ADEQUATE MATERIALS BELOW FOOTINGS

EXCAVATIONS EXTEND TO PROPER DEPTH ANDREACH PROPER MATERIAL

CLASSIFY & TEST CONTROLLED FILL MATERIALS

PERFORM MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF CONTROLLED FILL.

SHEAR WALL & DIAPHRAGM NAILING

DRAG STRUTS

BRACES & SHEAR PANELS

HOLDOWNS

CONCRETE CONSTRUCTION (IBC 1705.3)

SPECIAL INSPECTION SCHEDULE 1, 2

PRE-FAB CONSTRUCTION (IBC 1704.2)

WOOD (IBC 1705.5 & 1705.11.1 & 1705.12.2)

SOILS (IBC 1705.6)

1. SPECIAL INSPECTION IS NOT REQUIRED WHERE THE WORK IS DONE ON THE PREMISES OF A FABRICATOR REGISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION, PROVIDED THE FABRICATOR COMPLIES WITH IBC.

2. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS IF THE MATERIAL USED IN THE CONSTRUCTION TOOK PLACE ON SITE. SPECIAL INSPECTION WILL NOT BE REQUIRED DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE OF COMPLIANCE. (SEE NOTE 2).

1. SPECIAL INSPECTION IS NOT REQUIRED FOR CONC. ISOLATED SPREAD FOOTINGS, CONTINUOUS FOOTINGS, NON-STRUCTURAL SLABS, FOUNDATION WALLS, PATIOS, DRIVEWAYS, AND SIDEWALKS PROVIDED THE REQUIREMENTS OF IBC 1705.3 ARE MET.

2. PERIODIC SPECIAL INSPECTION IS ALLOWED FOR VERIFICATION OF THE WELDABILITY OF REINFORCING STEEL RESISTING FLEXURAL AND AXIAL FORCES IN INTERMEDIATE AND SPECIAL MOMENT FRAMES, BOUNDARY ELEMENTS OF SPECIAL REINFORCED CONCRETE SHEAR WALLS, AND SHEAR REINFORCEMENT. PERIODIC SPECIAL INSPECTION IS ALLOWED FOR WELDING OF OTHER ASTM A 706 REINFORCING STEEL NOT INCLUDED IN THE CONTINUOUS SPECIAL INSPECTION REQUIREMENTS NOTED ABOVE.

3. PERFORM AIR, SLUMP AND TEMP. TESTS WHEN CONCRETE SAMPLES ARE CAST.4. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR VERIFICATION OF IN-SITU CONCRETE STRENGTH FOR POST-TENSIONED

CONCRETE PRIOR TO TENSIONING TENDONS OR REMOVING SHORING OR FORMS.5. EPOXY AND EXPANSION ANCHORS INTO MASONRY OR CONCRETE MAY BE USED ONLY WHEN APPROVED BY ARCHITECT. AND/OR

ENGINEER USING AN APPROVED PRODUCT WITH CURRENT PUBLISHED ICC RESEARCH REPORT NUMBERS. COORDINATE CONTINUOUS/PERIODIC SPECIAL INSPECTION REQUIREMENTS WITH ICC REPORT.

1. WOOD STRUCTURAL PANEL SHEATHING SHALL BE INSPECTED TO ASCERTAIN THAT GRADE AND THICKNESS ARE IN COMPLIANCE WITH APPROVED BUILDING PLANS. NOMINAL SIZE OF FRAMING MEMBERS AT ADJOINING PANEL EDGES, THE NAIL OR STAPLE DIAMETER AND LENGTH, THE NUMBER OF FASTENER LINES, AND SPACING BETWEEN FASTENERS IN EACH LINE AND AT EDGE MARGINS SHALL ALSO BE INSPECTED AND VERIFIED FOR COMPLIANCE WITH APPROVED BUILDING PLANS.

2. SPECIAL INSPECTION IS NOT REQUIRED FOR WOOD SHEAR WALLS, WOOD DIAPHRAGMS, INCLUDING NAILING, & BOLTING, AND OTHER FASTENING TO OTHER COMPONENTS WHERE THE SPACING OF THE SHEATHING FASTENERS IS GREATER THAN 4"o.c.

3. SPECIAL INSPECTION SHALL BE PERFORMED TO VERIFY THAT THE INSTALLATION OF TEMPORARY AND PERMANENT RESTRAINT/BRACING IS INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE.

1. SPECIAL INSPECTION OF SOILS SHALL REFERENCE THE APPROVED SOILS REPORT TO DETERMINE COMPLIANCE.2. WHERE SOILS REPORT IS NOT PROVIDED SPECIAL INSPECTIONS ARE REQUIRED TO VERIFY THAT THE IN-PLACE DRY DENSITY OF

THE COMPACTED FILL IS NOT LESS THAN 90 PERCENT OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT DETERMINED IN ACCORDANCE WITH ASTM D 1557.

GLUING OPERATIONS

1. THE ITEMS MARKED WITH A " " IN THE SPECIAL INSPECTION SCHEDULE SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17 BY A CERTIFIED SPECIAL INSPECTOR FROM AN ESTABLISHED TESTING AGENCY. FOR MATERIAL SAMPLING AND TESTING REQUIREMENTS, REFER TO THE MATERIAL SAMPLING AND TESTING SECTION, THE PROJECT SPECIFICATIONS, AND THE SPECIFIC GENERAL NOTES SECTIONS. THE TESTING AGENCY SHALL SEND COPIES OF ALL STRUCTURAL TESTING AND INSPECTION REPORTS DIRECTLY TO THE ARCHITECT, ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL. ANY ITEMS WHICH FAIL TO COMPLY WITH THE APPROVED CONSTRUCTION DOCUMENTS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF DISCREPANCIES ARE NOT CORRECTED, THEY SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING OFFICIAL, ARCHITECT, AND ENGINEER PRIOR TO COMPLETION OF THAT PHASE OF WORK. SPECIAL INSPECTION TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS.

2. ANY CONSTRUCTION OR MATERIAL THAT HAS FAILED INSPECTION SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT.3. CONTINUOUS SPECIAL INSPECTION MEANS THE FULL-TIME OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORMED. PERIODIC SPECIAL INSPECTION MEANS THE

PART-TIME OR INTERMITTENT OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED AND AT THE COMPLETION OF THE WORK. (IBC SECTION 202)

FF

W

W

W

C

C

CC

C

P

P

METAL-PLATE-CONNECTED WOOD TRUSSES WITH HEIGHTS GREATER THAN OR EQUAL TO 60"

REFERENCE NOTE W2

METAL-PLATE-CONNECTED WOOD TRUSSES WITH SPANS GREATER THAN OR EQUAL TO 60 FEET

REFERENCE NOTE W3

TYPE STRENGTH

FOR CONCRETE APPLICATIONS (ACI 318 - 14)

BAR LOCATIONCONCRETE

#3

BAR SIZE

CONCRETE REINFORCING & SPLICE LENGTHS (IN)

2018 IBC CONCRETE REBAR LAP SPLICE SCHEDULE

VERT. WALL BARS, FILL ON METAL DECK

NWC 4500 PSI 14

NOTES :1. MECHANICAL COUPLERS MAY BE USED IN LIEU OF LAP SPLICES SHOWN. SEE STRUCTURAL NOTES FOR MINIMUM COUPLER CAPACITY. WHERE MECHANICAL COUPLERS ARE USED, STAGGER ADJACENT SPLICES A MINIMUM OF 24" AS

INDICATED ABOVE.2. DEVELOPMENT LENGTHS SHALL BE INCREASED BY 50% FOR STRAIGHT BAR DEVELOPMENT AND 20% FOR HOOKED BARS WHERE EPOXY COATING IS USED.3. WHEN SPLICING BARS OF DIFFERENT SIZES, USE LAP SPLICE LENGTH OF LARGER BARS UNO.4. SPLICE BARS LARGER THAN #11 USING MECHANICAL COUPLERS.

HORIZ. WALL BARS, FOOTING TOP BARS

BEAM BOTTOM BARS, COLUMN BARS

FOOTING BOTTOM BARS

BEAM TOP BARS

SLAB ON GRADE

NWC 4500 PSI

NWC 4500 PSI

NWC 4500 PSI

NWC 4500 PSI

NWC 4500 PSI

ℓd ℓs ℓdh

18 7

14 18 7

14 18 7

12 16 7

18 23 7

12 16 7

#4

18

ℓd ℓs ℓdh

23 6

#5

ℓd ℓs ℓdh

#6

ℓd ℓs ℓdh

#7

ℓd ℓs ℓdh

18 23 6

18 23 9

12 16 6

24 31 9

12 16 6

#8

ℓd ℓs ℓdh

#9

ℓd ℓdh

#10

ℓd ℓdh

#11

ℓd ℓdh

23 30 8

23 30 8

23 30 11

14 18 8

30 39 11

14 18 8

27 35 9

27 35 9

27 35 13

17 22 9

35 46 13

17 22 9

40 52 11

40 52 11

40 52 16

24 31 11

51 66 16

27 35 11

45 59 13

45 59 13

45 59 18

27 35 13

59 77 18

34 44 13

66 14

66 14

66 20

40 14

86 20

57 14

73 16

73 16

73 22

44 16

95 22

73 16

81 25

81 25

81 25

48 25

104 25

81 25

TYPE STRENGTH

BAR LOCATIONCONCRETE

#3

BAR SIZE

CONCRETE REINFORCING & SPLICE LENGTHS (IN)

VERT. WALL BARS, FILL ON METAL DECK

NWC 3000 PSI 17

HORIZ. WALL BARS, FOOTING TOP BARS

BEAM BOTTOM BARS, COLUMN BARS

FOOTING BOTTOM BARS

BEAM TOP BARS

SLAB ON GRADE

NWC 3000 PSI

NWC 3000 PSI

NWC 3000 PSI

NWC 3000 PSI

NWC 3000 PSI

ℓd ℓs ℓdh

22 8

#4

22

ℓd ℓs ℓdh

29 8

#5

ℓd ℓs ℓdh

#6

ℓd ℓs ℓdh

#7

ℓd ℓs ℓdh

#8

ℓd ℓs ℓdh

#9

ℓd ℓdh

#10

ℓd ℓdh

#11

ℓd ℓdh

28 36 10 33 43 12 48 62 13 55 72 15 81 17 90 19 99 30

17 22 8

17 22 8

12 16 8

22 29 8

12 16 8

22 29 8

22 29 11

14 18 8

29 38 11

14 18 8

28 36 10

28 36 14

17 22 10

36 47 14

17 22 10

33 43 12

33 43 16

20 26 12

43 56 16

20 26 12

48 62 13

48 62 19

29 38 13

63 82 19

32 42 13

55 72 15

55 72 22

33 43 15

72 94 22

42 55 15

81 17

81 25

48 17

105 25

69 17

90 19

90 27

55 19

117 27

90 19

99 30

99 30

60 30

127 30

99 30

DEVELOPMENT LENGTH

ℓd

LAP SPLICE LENGTH

ℓs

FACE OF JOINT OR CRITICAL SECTION

FACE OF JOINT OR CRITICAL SECTION

ℓdh

CLEAR

2' - 0"

COUPLER ORWELDED SPLICE

HOOK DEVELOPMENT LENGTH

COMMENTS

COMMENTS

ℓs

ℓs

ℓs

ℓs

ℓs

ℓs

51

51

51

31

66

44

56

56

56

34

73

56

62

62

62

37

80

62

62 69 76

62

62

37

81

53

69

69

42

90

69

76

76

46

98

76

WALL MARK

CONNECTION NAILING A.B. @ FOUND.

BLKG.TO TOP PL.

C

DIA. SPA.COMMENTS

WOOD SHEAR WALL SCHEDULE WOOD SHEAR WALL SCHEDULE CONT.

SW-2

SW-1 15/32" 3/4" DIA.(2) ROWS OF16d @ 8"o.c.

32"o.c.A35 @ 24"o.c.10d @ 6"o.c. 2 x

15/32" 3/4" DIA. 16"o.c.10d @ 4"o.c. 2 x 3 x

NAILING TOP PL.

TOGETHER B

(NOTE 6) NOM. STUD SIZE (MIN.)

NOMINAL BOTTOM

PLATE SIZE

EDGE NAILING

(E.N.) (SEE NOTES 2 &

3)

(NOTE 8)PLYWOOD

SHEATHING(CDX U.N.O.)

NOTES:

1. ALL SHEATHING PANEL EDGES TO BE BLOCKED. USE 3x BLOCKING WEHRE 3x STUDS ARE REQ'D.2. ALL NAILS TO BE COMMON OR GALV. BOX.3. FIELD NAILING TO BE SAME NAILS @ 12"o.c.4. AT SHEAR WALLS W/ SHEATHING ON BOTH SIDES, BOTH VERTICAL AND HORIZONTAL JOINTS ON OPPOSITE SIDES OF THE WALL SHALL BE

STAGGERED.5. STAGGER E.N. AT DOUBLE TOP PLATES.6. 3x NOMINAL FRAMING MEMBERS TO OCCUR AT ABUTTING PANEL EDGES. 2x NOMINAL FRAMING MEMBERS MAY BE USED AT INTERIOR OF PANEL,

UNLESS NOTED OTHERWISE IN FLOOR FRAMING NOTES. 4x NOMINAL FRAMING MEMBERS OF THE SAME DEPTH AND LUMBER GRADE MAY BE USED IN LIEU OF 3x MEMBERS AT CONTRACTOR OPTION.

7. SHEATHING SHALL BE STAMPED W/ APA STAMP. O.S.B. OF EQUIVALENT THICKNESS, GRADE, AND RATING MAY BE USED IN LIEU OF PLYWOOD.8. ALL A.B.TO HAVE MIN. 8" EMBEDMENT INTO CONCRETE.9. SEE THIS SHEET FOR TYPICAL SHEAR TRANSFER DETAILS.10. WHERE SHEAR WALL PANELS HAVE TO BE CONSTRUCTED SEPARATELY, ATTACH ADJOINING 2x STUDS TOGETHER W/ (2) ROWS OF 16d NAILS @

6"o.c. STAGGERED. SUBMIT PROPOSED JOINT LAYOUT & DETAIL TO EOR FOR APPROVAL PRIOR TO CONSTRUCTION.11. REFER TO THE FOOTING & FOUNDATION PLAN NOTES FOR HOLDOWN LOCATIONS & INFORMATION.12. SEE STRUCTURAL NOTES FOR REQUIRED 1/4" x 3" x 3" PLATE WASHERS.

2 x

(2) ROWS OF16d @ 8"o.c.

A35 @ 24"o.c.

SW-3 15/32" 3/4" DIA. 16"o.c.10d @ 3"o.c. 3 x 3 x(2) ROWS OF16d @ 8"o.c.

A35 @ 16"o.c.

WALL SUPPORTING ROOF TRUSSES

WALL SUPPORTING ROOF OUTLOOKER

ROOF

SHEAR TRANSFER DETAILS

ROOF RAFTER

DIAPHRAGM BOUNDARY NAILING SEE STRUCTURAL NOTES

C

B

E.N.FULL HEIGHT SOLID BLOCKING SEE 6/S2.02

ROOF TRUSS

SHEAR WALL

B

C

DIAPHRAGM BOUNDARY NAILING - SEE STRUCTURAL NOTES

FULL HEIGHT SOLID BLOCKING - SEE 6/S2.02

E.N.

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

ARW:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF

FA

CIL

ITIE

S C

ON

ST

RU

CT

ION

AN

D M

AN

AG

EM

EN

T

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

HKS: 22564.000

C:\

Users

\am

monh\D

ocum

ents

\S-1

9467-C

am

p W

illia

ms

4141-2

019_ja

sonr@

arw

engin

eers

.com

.rvt

2/1

4/2

020 1

1:0

8:3

9 A

M

S0.02

SCHEDULES

14 FEBRUARY 2020

19467

CONSTRUCTION

DOCUMENTS

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

Page 16: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

PRE-MANUFACTURED TRUSSES @ 24"o.c.

2x6 O

UT

LO

OK

ER

S @

24"o

.c.

2x6 O

UT

LO

OK

ER

S @

24"o

.c.

1

2

B

A

HDU4

(2) 2x

6

HDU4

(2) 2x

6

HDU2

(2) 2x

6

HDU2

(2) 2x

6

HDU2

(2) 2x

6HDU2

(2) 2x

6HDU2

(2) 2x

6HDU2

(2) 2x

6

HDU2

(2) 2x

6 HDU2

(2) 2x

6 HDU2

(2) 2x

6

SW-1

13' - 0"

SW-1

28' - 0"

SW-1

7' - 0"

(2) 2x6 TRIMMERS(2) 2x6 KING STUDS

SW-2

4' - 8"

SW-1

19' - 6"

(2) 2x6 TRIMMERS(1) 2x6 KING STUDSSW-1

21' - 0"

SW-1

25' - 0"

FC2

98' - 0"

FC2

98' - 0"

FC2

98' - 0"

FC2

98' - 0"

5

S2.01

TYP.

6

S2.01

5

S2.01

5

S2.01

TYP.

TYP.

6

S2.01

6

S2.01

5

S2.01TYP.

1

2

B

A

(3) 2x8 (3) 2x8

(3) 2x10(2) 2x8(2) 2x8

(2)

2x8

(2)

2x8

DO

UB

LE

TR

US

S

DO

UB

LE

TR

US

S

9

S2.02

TYP.

10

S2.02

TYP.

10

S2.02

TYP.

11

S2.02

TYP.

9

S2.02

TYP.

CONTINUOUS 2x8 FASCIA -MINIMUM 10'-0" LONG -TYPICAL @ ALL CORNERS

'L' 1.5 'L' 1.5 'L' 'L'

WOOD FRAMING NOTES:

1. FOR ROOF SHEATHING AND NAILING REQUIREMENTS, SEE STRUCTURAL NOTES SHEET S0.01.2. SHEAR WALLS ARE INDICATED ON SHEET S0.02. SEE THE SHEAR WALL SCHEDULE FOR SHEAR WALL

ATTACHMENTS.3. AT TOP PLATE SPLICE, LAP 4'-0" MIN. AND CONNECT WITH MIN (28) 10d COMMON NAILS.4. SEE DETAIL 5/S2.02 FOR OPENINGS IN ROOF DIAPHRAGM.5. U.N.O., ALL EXTERIOR WALLS, INTERIOR BEARING WALLS AND SHEAR WALLS SHALL BE SHEATHED AND

HAVE 2x6 STUDS @ 16"o.c. OTHER WALLS TO BE AS PER ARCHITECTURAL DRAWINGS.6. TYPICAL HEADERS WHERE NOT OTHERWISE INDICATED TO BE AS FOLLOWS (SEE DETAIL 11/S2.02):

a. UP TO 4'-0" OPENING (3) 2x8 4'-1"b. TO 5'-6" (3) 2x10

7. FOR TYPICAL TRIMMERS, WHERE NOT OTHERWISE INDICATED, SEE DETAIL 2/S2.028. FOR TYPICAL KING STUDS, WHERE NOT OTHERWISE INDICATED, SEE DETAIL 2/S2.029. SEE DETAIL 6/S2.02 FOR PLYWOOD ROOF SHEATHING LAYOUT.10. CONTRACTOR SHALL ERECT AND MAINTAIN ADEQUATE TEMPORARY BRACING UNTIL ALL ROOF FRAMING

AND ROOF DIAPHRAGM ATTACHMENTS ARE COMPLETE.11. SEE DETAIL 4/S2.02 FOR ATTACHMENT OF NON-BEARING WALLS TO PRE-MANUFACTURED TRUSSES.

PRE-MANUFACTURED TRUSS NOTES:

1. PRE-MANUFACTURED TRUSSES SHALL BE DESIGNED PER ALL APPLICABLE LOAD COMBINATIONS AND LOAD CONFIGURATIONS AS REQUIRED BY THE GOVERNING CODE AND THE GENERAL STRUCTURAL NOTES:

THE FOLLOWING CRITERIA SHALL BE USED IN DESIGN.A. SNOW LOAD = PER GENERAL STRUCTURAL NOTESB. LIVE LOAD = PER GENERAL STRUCTURAL NOTESC. DEAD LOAD = 10 PSF TOP CHORD

5 PSF BOTTOM CHORDD. WIND LOAD = PER GENERAL STRUCTURAL NOTESE. SNOW DRIFT = AS DETERMINED BY THE TRUSS MANUFACTURER. CONSIDER BALANCED,

UNBALANCED AND DRIFT LOCATIONS2. ALL TRUSSES SHALL BE DESIGNED FOR A 150 POUND POINT LOAD APPLIED AT ANY LOCATION ALONG THE

BOTTOM CHORD. DESIGN ALL TRUSSES FOR WIND UPLIFT PER THE GOVERNING CODE WITH A 8 PSF DEAD LOAD.

3. ALL TRUSS TO TRUSS CONNECTIONS PROVIDED BY TRUSS MANUFACTURER. 4. TRUSS MANUFACTURER SHALL COORDINATE AND INCLUDE ALL ADD LOADS FROM

MECHANICAL/ELECTRICAL EQUIPMENT, ARCH ATTACHMENTS, ETC. COORDINATE WITH ARCH./MECH. DRAWINGS.

5. COORDINATE DUCT RUNS AND TRUSS WEB CONFIGURATIONS WITH MECHANICAL & ARCH. DRAWINGS. DO NOT FIELD MODIFY TRUSSES TO ACCOMMODATE DUCTING AND OTHER MISCELLANEOUS EQUIPMENT WITHOUT WRITTEN DIRECTION FROM THE TRUSS MANUFACTURER OR STRUCTURAL ENGINEER.

6. INSTALL SIMPSON H2.5A HURRICANE TIES @ EACH TRUSS AS SHOWN IN DETAIL 9/S2.02. TRUSS MANUF. TO VERIFY THAT THIS SIMPSON H2.5A TIE MEETS OR EXCEEDS REQUIRED UPLIFT CAPACITIES FOR ALL TRUSSES DESIGNED. TRUSS MANUF. RESPONSIBLE TO NOTIFY EOR IN WRITING WHERE UPLIFT CAPACITIES ARE EXCEEDED.

7. COORDINATE ALLOWABLE TRUSS DEFLECTIONS WITH ARCHITECT FOR DETAILING OF NON-BEARING STUD WALLS BELOW.

8. WHERE CORNER OUTLOOKERS OCCUR, TRUSS MANUFACTURER SHALL DESIGN THE FASCIA BOARD & ITS CONNECTION TO THE TRUSS AROUND THE PERIMETER OF THE ENTIRE BUILDING. THE FASCIA BOARD SHALL BE CAPABLE OF SUPPORTING GRAVITY LOADS (DEAD AND SNOW) AND WIND UPLIFT LOADS.

9. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND CALCULATIONS FOR REVIEW AS REQUIRED BY THE DEFERRED SUBMITTAL SECTION OF THE GENERAL STRUCTURAL NOTES.

FOOTING & FOUNDATION NOTES

1. SEE SHEET S0.01 FOR GENERAL STRUCTURAL NOTES.2. ALL FOOTINGS SHALL BE PLACED ON SOIL WHICH HAS BEEN PREPARED FOR THE BEARING PRESSURE

SHOWN IN THE STRUCTURAL NOTES.3. VERIFY ALL DIMENSIONS WITH DRAWINGS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOUND.4. SEE SHEET S0.02 FOR FOOTING SCHEDULE.5. SEE SHEET S2.01 FOR TYPICAL FOOTING AND FOUNDATION DETAILS.6. ALL EXTERIOR WALL FOOTINGS TO BEAR A MINIMUM DIMENSION BELOW EXTERIOR GRADE AS NOTED IN

GENERAL STRUCTURAL NOTES.7. FOUNDATION WALLS ARE DESIGNED AND DETAILED FOR THE COMPLETED CONDITION. CONTRACTOR IS

RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION. BACKFILLED WALLS SHALL BE ADEQUATELY BRACED DURING CONSTRUCTION AND BACKFILLING TO PRODUCE PLUMB AND TRUE FINISHED WALLS.

8. ALL ANCHORS, HOLD-DOWNS, ANCHOR BOLTS, DOWELS, EMBEDDED ITEMS, ETC. SHALL BE HELD IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.

9. COORDINATE ALL FOOTING DEPTHS (INTERIOR AND EXTERIOR) WITH DRAINS, CONDUITS, ETC. THAT MAY INTERFERE WITH FOOTINGS.

CONCRETE SLAB NOTES

1. SLAB ON GRADE SHALL BE 4" THICK CONCRETE U.N.O. SLAB SHALL BE UNDERLAIN BY FREE DRAINING MATERIAL AS PRESCRIBED IN THE SOILS REPORT.

2. SEE SHEET S2.01 FOR CONTROL AND CONSTRUCTION JOINT INFORMATION.

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

ARW:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF

FA

CIL

ITIE

S C

ON

ST

RU

CT

ION

AN

D M

AN

AG

EM

EN

T

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

HKS: 22564.000

C:\

Users

\am

monh\D

ocum

ents

\S-1

9467-C

am

p W

illia

ms

4141-2

019_ja

sonr@

arw

engin

eers

.com

.rvt

2/1

4/2

020 1

1:0

8:4

0 A

M

S1.01

FOOTING,

FOUNDATION & ROOF

FRAMING PLAN

14 FEBRUARY 2020

19467

CONSTRUCTION

DOCUMENTS

SCALE : 1/4" = 1'-0" S1.01

AFOOTING AND FOUNDATION PLAN

SCALE : 1/4" = 1'-0" S1.01

BROOF FRAMING PLAN

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

Page 17: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

CONTROL JOINTCONSTRUCTION JOINT

DIAMOND BLOCKOUT AT COLUMNS

CONCRETE FLOOR SLAB

POUR #1

POUR #2

POUR #3 T = SLAB THICKNESS

SCALE : NONE

CONCRETE FLOOR SLAB

SCALE : NONE

PLATE DOWELS AT 24"o.c. OR 1/2" DIA. x 18" UNBONDED DOWELS AT 18"o.c.

NOTES:1. JOINTS SHALL OCCUR AT MAIN COLUMN / GRID LINES

W/ 10'-0" MAX. SPACING BETWEEN JOINTS AT 4" SLABS;12'-0" MAX. AT 5" SLABS, AND 15'-0" MAX. AT 6" SLABS.

2. SEE PLAN FOR SLAB THICKNESS 'T' AND REINFORCING SIZE AND SPACING.

T = SLAB THICKNESS

NOTE: THICKENING OF SLAB NOT REQUIRED FOR SLABS WITH T = 6" OR GREATER

A

B

T

t/4

SAWN OR FORMED JOINT

AB

SLAB REINFORCEMENT(WHERE OCCURS)

SLAB REINFORCEMENT (WHERE OCCURS) TERMINATE 3" FROM EACH SIDE OF CONSTRUCTION JOINTS

'T'

18" 18"

MIN

.

6"

1

1

FOOTING OUTLINE

FOOTING REINFORCING (TOP STEEL WHERE OCCURS)

TYP. FOUNDATION REINFORCEMENT

(2) #6 DOWELS (AT CONCRETE FOUNDATION WALLS ONLY)

TYP. FOUNDATION REINFORCEMENT

T = FOOTING THICKNESSH = FOOTING STEP HEIGHT

30"

NOTES : 1. FOUNDATION REINFORCING NOT SHOWN FOR CLARITY.2. SEE FOOTING SCHEDULE FOR FOOTING WIDTH AND

REINFORCING SIZE AND LOCATION. ALL FOOTING REINFORCING REFERENCED IN THE SCHEDULE OR SHOWN IN THE DETAILS MUST RUN CONTINUOUS THROUGH THE FOOTING STEP.

2 x 'H'

MIN

.'T'

'T'

24

" M

AX

. (U

.N.O

.)

'H'

24"

24" MIN

.

PIPE CROSSING FOOTING / FOUNDATION WALL

PIPE PARALLEL TO FOOTING

CONCRETE OR CMU FOUNDATION WALL

(1) #5 x REQ'D ABOVE & BELOW SLEEVE IN FOUNDATION WALLS

BOTTOM OF FOOTING

THICKEN FOOTING WHERE PIPE IS LESS THAN 24" BELOW BOTTOM OF FOOTING

PIPE TO CLEAR SLEEVE BY 1" ALL AROUND

NO DIGGING FOR PIPE TRENCH PARALLEL TO FOOTING WITHIN THIS BOUNDARY

12

UTILITY TRENCHES BACK FILL AND COMPACT PER GEOTECHNICAL REPORT

NOTES : 1. TYP. FOUNDATION WALL REINFORCING NOT SHOWN FOR

CLARITY.2. FOR OPENINGS LARGER THAN 12" IN ANY DIRECTION. SEE

STRUCTURAL NOTE E-7.3. DETAIL IS SIMILAR AT MASONRY FOUNDATION WALLS.4. DISTANCE 'L' SHALL BE THE GREATER OF (d1 +d2)/2 OR 4".

NO PIPES ALLOWED TO PASS THROUGH FTGS. OR GRADE BEAMS

4" MIN. 24" MAX.

SLE

EV

E 4"

MIN

.

.

5"

SLE

EV

E

12" 12"

18"

12" MIN. Ld1 d2

INTERSECTION CORNER

INTERSECTION CORNER

DOUBLE MAT

SINGLE MAT

ALTERNATE BENDS, TYP.

NOTES:1. ℓs = LAP SPLICE LENGTH - SEE REBAR LAP SCHEDULE.2. VERTICAL BARS NOT SHOWN.3. THIS DETAIL IS APPLICABLE AT ALL FOOTINGS AND

FOUNDATION WALLS.

ℓsℓsℓsℓs

ℓs

ℓs ℓs

E.N. - SEE STRUCTURAL NOTES

WOOD STUD WALL -SEE PLAN AND SCHEDULE

CONCRETE SLAB - SEE PLAN / NOTES FOR THICKNESS AND REINFORCING

CONCRETE FOUNDATION WALL -SEE PLAN AND STRUCTURAL NOTES FOR SIZE AND REINFORCING CONCRETE FOOTING -

SEE PLAN AND SCHEDULEFOR SIZE AND REINFORCING

MASONRY VENEER -SEE STRUCTURAL NOTES FOR ATTACHMENT TO WALL

WALL SHEATHING - SEE STRUCTURAL NOTES

SEE SHEAR WALL SCHEDULE OR STRUCTURAL NOTES FOR ANCHOR SIZE AND SPACING

2x REDWOOD OR PRESSURE TREATED PLATE

FROSTDEPTH MIN.

CONCRETE SLAB (EXTERIOR, WHERE OCCURS)

CONCRETE FOUNDATION WALL -SEE PLAN AND STRUCTURAL NOTES FOR SIZE AND REINFORCING

CONCRETE SLAB (INTERIOR) -SEE PLAN / NOTES FOR THICKNESS AND REINFORCING

#4 DOWELS AT 24"o.c.

STEP CONT. TOP BARS BELOW RECESS

CONCRETE FOOTING -SEE PLAN AND SCHEDULEFOR SIZE AND REINFORCING

24"REQ'D

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

ARW:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF

FA

CIL

ITIE

S C

ON

ST

RU

CT

ION

AN

D M

AN

AG

EM

EN

T

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

HKS: 22564.000

C:\

Users

\am

monh\D

ocum

ents

\S-1

9467-C

am

p W

illia

ms

4141-2

019_ja

sonr@

arw

engin

eers

.com

.rvt

2/1

4/2

020 1

1:0

8:4

0 A

M

S2.01

DETAILS

14 FEBRUARY 2020

19467

CONSTRUCTION

DOCUMENTS

SCALE : NONE S2.01TYPICAL CONCRETE SLAB JOINTS 1

SCALE : NONE S2.01

2TYPICAL STEPPED FOOTINGSCALE : NONE S2.01ALLOWABLE PIPING LOCATIONS @ FOOTING DETAIL 3

SCALE : NONE S2.01

4TYP. REINF. @ INTERSECTIONS IN CONC.DETAIL

LSCALE : NONE S2.01

5SECTION @ EXTERIOR TIMBERSECTION @ EXTERIOR TIMBERSCALE : NONE S2.01

6CONCRETE FOUNDATION @ OPENING

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

Page 18: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

HEADED ANCHOR BOLTS -SEE SCHEDULE FOR SIZE AND SPACING

EDGE POST - SEE PLAN PLYWOOD SHEATHING -LAY LONG EDGE HORIZONTAL - SEE SCHEDULE FOR SIZE

HOLDOWN - SEE SCHEDULE

EDGE POST - SEE PLAN

BLOCKING REQ'D AT PANEL EDGES (USE 3x BLOCKING IN WALL TYPES REQUIRING 3x STUDS AT PANEL EDGES)

PLATE WASHER 1/4" x 3" x 0'-3", TYP.

SIMPSON SB ANCHORSEE DETAIL 2 AND 3/S2.02

SOLID WOOD BLOCKING TYP.BETWEEN RAFTERS AND TRUSSES.ALL BEARING AND SHEAR WALLSNOTCH WHERE REQ'D FORVENTILATION - SEE DETAIL 6/S2.02

3x STUD WALL FRAMING AND 3x BOTTOM PLATE WHERE REQ'D - SEE SCHEDULE

BLOCKING TO TOP PLATE ATTACHMENT "C" - SEE SCHEDULE

PANEL EDGE NAILSPACING

FIELD NAILSPACING

2x OR 3x STUD WALL FRAMING - SEE SCHEDULE

OPENING SIZE KING STUDS TRIMMER STUDS

DOUBLE 2x WALL TOP PLATE - SEE ROOF FRAMING NOTES

CRIPPLE STUDS (WHERE OCCURS)

HEADER BEAM - SEE PLAN AND 4/S2.02

TRIMMER STUDS - SEE SCHEDULE

KING STUDS - SEE SCHEDULE

SIMPSON LCE4 POST CAP - TYP. EACH SIDE

UP TO 6'-0"

6'-1" TO 10'-0"

(2) 2x6

(3) 2x6(2) 2x6

(2) 2x6

WALL TOP PLATE

SOLID 2x BLOCKING BETWEEN TRUSSES AND RAFTERS. NOTCH CORNERS AS SHOWN WHERE REQ'D FOR VENTILATION

ROOF SHEATHING - SEE STRUCTURAL NOTES

ROOF TRUSS OR RAFTER - SEE PLAN

BLOCKING TO TOP PLATE ATTACHMENT -SEE SCHEDULE

NOTE: FOR DEPTHS GREATER THAN 11-1/4" USE SOLID LSL BLOCKING BETWEEN RAFTERS.

WALL PARALLEL TO TRUSSES WALL PERPENDICULAR TO TRUSSES

(2) 8d EACH SIDE

2x8 TOP PLATE

2x4 FLAT AT 48"o.c. DO NOT NAIL TO TRUSS

16d AT 12"o.c.

FASTEN MASTER NLB SCREW AT EACH TRUSS1

" C

LE

AR

MAX. OPENING 4'-0" x 4'-0"

DOUBLE JOIST

" U " JOIST HANGER - TYP.

DOUBLE HEADER JOIST

DOUBLE JOIST

EDGE NAILING ALL AROUND OPENING

AT ROOF

B.N. = BOUNDARY NAILING

F.N. = FIELD NAILINGE.N. = EDGE NAILING

4'-0" x 8'-0" TYP.SHEATHING

EDGE SHEATHING JOINTS TOBE CENTERED ON JOISTS

EDGE OF ROOF1/8" PANEL GAP(TYP.)

BLOCKING ABOVE WALLBELOW (WHERE OCCURS)

E.N. - TYP.

B.N. - TYP.

F.N. TYP.

SUPPORT UNBLOCKEDPANEL EDGES W/SIMPSON PSCL PANEL CLIPS -TYP. BETWEEN TRUSSESAT MIDSPAN OF SHEATHING

STAGGER JOINTSAT 4'-0"o.c.

WOOD STUDS - SEE SHEAR WALL SCHEDULE AND FRAMING NOTES

SEE SHEAR WALL SCHEDULE FOR BOLTED ATTACHMENT TO FOUNDATION. PROVIDE 1/4" x 3" x 0'-3" PLATE WASHERS TYP. AT EACH ANCHOR BOLT

SILL PLATE

CONCRETE FOOTING OR FOUNDATION WALL -SEE PLAN FOR SIZE

SIMPSON HOLDOWN ANCHOR W/ ANCHOR BOLT PER PLAN AND DETAIL 3/S2.02

BOUNDARY POST PER PLAN

APA RATED SHEATHING AT ALL SHEAR WALLS -SEE SCHEDULE FOR PANEL NAILING

2x BLOCKING TYP. AT ALL PANEL EDGES. INSTALL 3x BLOCKING WHERE 3x STUDS ARE REQ'D - SEE SCHEDULE

CORNER / END WALL INSTALLATION

SECTION A

CONTINUOUS WALL INSTALLATION

ANCHORHOLDOWN SIZE SIZE

MIN. EMBEDMENTDEPTH "Le"

LOCATE MIN. 45 DEG.

HDU2

HDU4

SB 5/8 x 24

SB 5/8 x 24

20"

HDU5

HDU8

SB 5/8 x 24

SB 7/8 x 24

PLACE SB ANCHOR DIAGONAL IN CORNER AT END WALL APPLICATION

5"

MIN

.

1 3/4" MIN.

A

CONCRETE FOUNDATION WALL

20"

20"

20"

12"

SEE ARCH.

ROOF SHEATHING - SEE STRUCTURAL NOTES

B.N. - SEE STRUCTURAL NOTES

FULL HEIGHT SOLID 2x OR LSL BLOCKING TYP. BETWEEN TRUSSES - SEE 6/S2.02

E.N. - SEE STRUCTURAL NOTES

WALL SHEATHING - SEE STRUCTURAL NOTES AND WOOD SHEAR WALL SCHEDULE

ROOF TRUSS - SEE PLAN SIMPSON H2.5A AT EACH TRUSS

WOOD SHEAR WALL - SEE PLAN AND SCHEDULE

SIMPSON A35 AT EACH TRUSS

SIMPSON A35 AT EACH BLOCK

NOTE: SEE ARCH. FOR SOFFITAND FACIA DETAILS

OUTLOOKER - SEE PLAN

E.N. - SEE STRUCTURAL NOTES

WALL SHEATHING - SEE STRUCTURAL NOTES ANDSHEAR WALL SCHEDULE

B.N. INTO 2x SOLID BLOCKING - SEE STRUCTURAL NOTES

SIMPSON FACE MOUNT HANGER AT EACH OUTLOOKER MIN. CAPACITY = 500lb

SIMPSON H2.5A UPLIFTANCHOR AT 24"o.c.

2-PLY PRE-MANUFACTUREDROOF TRUSS - SEE PLAN

ROOF SHEATHING - SEE STRUCTURAL NOTES

SIMPSON A35 AT 24"o.c.

L 2L

(2) SIMPSON 4" SDS SCREWS TYPICAL

(2) PIECES (3) PIECES (4) PIECES

(2) ROWS 12d NAILS AT 12"o.c.

(2) ROWS 16d NAILS AT 12"o.c. (EACH SIDE STAGGERED)

(2) ROWS 1/2" DIA. THRU BOLTS AT 24"o.c.

2"

2"

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

ARW:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF

FA

CIL

ITIE

S C

ON

ST

RU

CT

ION

AN

D M

AN

AG

EM

EN

T

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

HKS: 22564.000

C:\

Users

\am

monh\D

ocum

ents

\S-1

9467-C

am

p W

illia

ms

4141-2

019_ja

sonr@

arw

engin

eers

.com

.rvt

2/1

4/2

020 1

1:0

8:4

2 A

M

S2.02

DETAILS

14 FEBRUARY 2020

19467

CONSTRUCTION

DOCUMENTS

LSCALE : NONE S2.02

1DETAILDETAILSCALE : NONE S2.02

5DETAIL

LSCALE : NONE S2.02

6DETAILDETAIL

SCALE : NONE S2.02

11TYP. NON-BEARING WALL

SCALE : NONE S2.02

7DETAILL

SCALE : NONE S2.02

8TYP. SHEATHING LAYOUT (UNBLOCKEDDIAPHRAGM)TYP. SHEATHING LAYOUT (UNBLOCKEDDIAPHRAGM)

LSCALE : NONE S2.02

2TYP. HOLDOWN DETAILTYP. HOLDOWN DETAILL

SCALE : NONE S2.02

3HOLDOWN EMBED SCHEDULEHOLDOWN EMBED SCHEDULE

LSCALE : NONE S2.02

9DETAILDETAILL

SCALE : NONE S2.02

10DETAILDETAIL

SCALE : NONE S2.02

4HEADER AND BEAM MEMBERCONNECTIONS

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

Page 19: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

NOTE: THIS VIEW REPRESENTS A SCHEMATIC RENDERING ONLY AND IS NOT INTENDED TO CONVEY CONSTRUCTION INFORMATION. ALL CONSTRUCTION SHALL COMPLY WITH SPECIFIC NOTES AND DETAILS WITHIN THE STRUCTURAL DRAWINGS.

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

ARW:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF

FA

CIL

ITIE

S C

ON

ST

RU

CT

ION

AN

D M

AN

AG

EM

EN

T

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

HKS: 22564.000

C:\

Users

\am

monh\D

ocum

ents

\S-1

9467-C

am

p W

illia

ms

4141-2

019_ja

sonr@

arw

engin

eers

.com

.rvt

2/1

4/2

020 1

1:0

8:4

4 A

M

S4.01

SCHEMATIC

REFERENCE

14 FEBRUARY 2020

19467

CONSTRUCTION

DOCUMENTS

SCALE : S4.01

A3D REFERENCEW VIEW ONLY

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

Page 20: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

02/14/2020

REG

I STE

RE

D PROFESS IONAL ENGIN

EER

No. 7715

S TA T E O F UTAH

RICHARD G.REEDER

181 East 5600 SouthMurray, Utah 84107O: (801) 530-3148www.vbfa.comvbfa project #: 18455

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

TD

ATE:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CAM

P W

ILLI

AMS

SHEETNO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UTAH

NAT

IONA

L GU

ARD

STAT

E OF

UTA

H DI

VISI

ON O

F FA

CILI

TIES

CON

STRU

CTIO

N AN

D M

ANAG

EMEN

T

OWNERSTATE OF UTAHDIVISION OF FACILITIESCONSTRUCTION AND MANAGEMENT4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 WBLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/14

/202

0 1:

33:5

4 PM

14 FEBRUARY 2020

22564.000

CONSTRUCTIONDOCUMENTS

BU

ILD

ING

414

1 R

EN

OV

AT

ION

S

M0.00

LEGEND OF MECHANICALSYMBOLS &ABBREVIATIONS

VTR

LEGEND OF MECHANICAL SYMBOLS AND ABBREVIATIONS

12X12200

22X22200

12X12200

24X10200

24X10200

12X12200

12X12200

S

T

RPBP

GPM0.0

O-100°

F

S

T

MECHANICAL

A

S

SD

PLUMBING PLUMBING CONT. LINETYPES LINETYPES CONT.

SYMBOLS

AutoCAD SHX Text
PS
AutoCAD SHX Text
N
AutoCAD SHX Text
LB/HR.
AutoCAD SHX Text
GPM
AutoCAD SHX Text
3-1" SLOTS
AutoCAD SHX Text
@ 48" 400
AutoCAD SHX Text
W
AutoCAD SHX Text
R
AutoCAD SHX Text
12/12
AutoCAD SHX Text
6
AutoCAD SHX Text
45%%D
AutoCAD SHX Text
D
AutoCAD SHX Text
FD
AutoCAD SHX Text
FSD
AutoCAD SHX Text
SD
AutoCAD SHX Text
OR
AutoCAD SHX Text
8/8
AutoCAD SHX Text
1.25D
AutoCAD SHX Text
AD
AutoCAD SHX Text
12/8 FO
AutoCAD SHX Text
ATC
AutoCAD SHX Text
CF
AutoCAD SHX Text
LATERAL STRAINER WITH BLOW-OFF VALVE, PROVIDE HOSE END WITH CAP WHERE DISCHARGE IS NOT PIPED TO DRAIN
AutoCAD SHX Text
F&T
AutoCAD SHX Text
AW
AutoCAD SHX Text
AV
AutoCAD SHX Text
HP(NAME)
AutoCAD SHX Text
N20
AutoCAD SHX Text
(NAME)
AutoCAD SHX Text
R
AutoCAD SHX Text
SINGLE DUCT AIR TERMINAL BOX VARIABLE OR CONSTANT VOLUME. MIN. 1-1/2 TERMINAL INLET SIZE STRAIGHT DUCT AT TERMINAL INLET.
AutoCAD SHX Text
HEATING OR COOLING COIL IN DUCT
AutoCAD SHX Text
ACCESS PANEL IN DUCT OR PLENUM
AutoCAD SHX Text
ATC DAMPER
AutoCAD SHX Text
SMOKE DAMPER W/ ACCESS PANEL
AutoCAD SHX Text
COMBINATION FIRE/SMOKE DAMPER W/ ACCESS PANEL
AutoCAD SHX Text
FIRE DAMPER IN DUCT, W/ ACCESS PANEL REQD.
AutoCAD SHX Text
MANUAL VOLUME DAMPER
AutoCAD SHX Text
HIGH EFFICIENCY FITTING
AutoCAD SHX Text
TAP ENTRY AREA EQUALS 150% OF BRANCH AREA
AutoCAD SHX Text
BRANCH DUCT SPLIT WITH 6" WIDTH AND MIN. R=WIDTH OF BRANCH DUCT DOWNSTREAM. ELBOW TURNING VANE OPTIONAL.
AutoCAD SHX Text
RECTANGULAR TO ROUND DUCT TRANSFORMATION
AutoCAD SHX Text
RECTANGULAR TO RECTANGULAR OR ROUND TO ROUND DUCT TRANSFORMATION MAXIMUM 15° INCLUDED ANGLEEXCEPT WHERE SHOWN OTHERWISE.
AutoCAD SHX Text
R/W=1. ROUND DUCT SIMILAR TO RECTANGULAR
AutoCAD SHX Text
INCLINED DROP
AutoCAD SHX Text
INCLINED RISE
AutoCAD SHX Text
WITH RESPECT TO AIR FLOW 15°NOMINAL INCLINE WITH RADIUS TURNS=DEPTH OF DUCT.
AutoCAD SHX Text
ROUND DUCT WITH FREE AREA DIMENSIONS SHOWN IN INCHES.
AutoCAD SHX Text
RECTANGULAR DUCT WITH FREE AREA DIMENSIONS SHOWN IN INCHES.
AutoCAD SHX Text
FLAT OVAL DUCT WITH FREE AREA DIMENSIONS SHOWN IN INCHES.
AutoCAD SHX Text
FAN
AutoCAD SHX Text
FLEXIBLE DUCT
AutoCAD SHX Text
FLEXIBLE DUCT CONNECTION
AutoCAD SHX Text
LINEAR DIFFUSER WITH PLENUM AND FLEXIBLE DUCT CONNECTION. NO. OF SLOTS & SIZE OF SLOT ON TOP, ACTIVE LENGTH AND CFM ON BOTTOM
AutoCAD SHX Text
CEILING AIR GRILLE WITH FLEXIBLE DUCT
AutoCAD SHX Text
CEILING SUPPLY DIFFUSER WITH FLEXIBLE DUCT
AutoCAD SHX Text
SIDEWALL EXHAUST OR RETURN REGISTER
AutoCAD SHX Text
SIDEWALL SUPPLY REGISTER
AutoCAD SHX Text
CEILING EXHAUST REGISTER, (BALANCE TO MATCH SUPPLY IF RETURN CFM IS NOT SHOWN)
AutoCAD SHX Text
CEILING RETURN REGISTER
AutoCAD SHX Text
CEILING SUPPLY DIFFUSER
AutoCAD SHX Text
RELIEF AIR OR EXHAUST AIR LOUVER
AutoCAD SHX Text
FRESH AIR LOUVER
AutoCAD SHX Text
TURNING VANES
AutoCAD SHX Text
UNDER FLOOR DUCT
AutoCAD SHX Text
ROUND DUCT - DROP
AutoCAD SHX Text
ROUND DUCT - RISE
AutoCAD SHX Text
NEGATIVE PRESSURE DUCT - DROP
AutoCAD SHX Text
TOP FIGURES INDICATE NECK SIZE. BOTTOM FIGURE INDICATES CFM.
AutoCAD SHX Text
12/8
AutoCAD SHX Text
12%%c
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
12/12
AutoCAD SHX Text
12%%c
AutoCAD SHX Text
1.5D
AutoCAD SHX Text
D
AutoCAD SHX Text
12%%C
AutoCAD SHX Text
12/12
AutoCAD SHX Text
FLANGE
AutoCAD SHX Text
PRESSURE GAUGE WITH PIGTAIL
AutoCAD SHX Text
PRESSURE GAUGE WITH SHUT-OFF COCK
AutoCAD SHX Text
ANCHOR
AutoCAD SHX Text
DEMOLITION
AutoCAD SHX Text
ALIGNMENT GUIDE
AutoCAD SHX Text
FLEXIBLE EXPANSION JOINT
AutoCAD SHX Text
SOLENOID VALVE
AutoCAD SHX Text
CHEMICAL FEED
AutoCAD SHX Text
HELICOPTER FUEL RETURN
AutoCAD SHX Text
HELICOPTER FUEL SUPPLY
AutoCAD SHX Text
FUEL OIL RETURN
AutoCAD SHX Text
FUEL OIL SUPPLY
AutoCAD SHX Text
HOT GAS
AutoCAD SHX Text
EXISTING PIPING TO BE REMOVED
AutoCAD SHX Text
LIQUIFIED PETROLEUM GAS
AutoCAD SHX Text
GLYCOL PIPING SOLUTION
AutoCAD SHX Text
GLYCOL HEAT RECOVERY PIPING
AutoCAD SHX Text
HEATING HOT WATER RETURN
AutoCAD SHX Text
HEATING HOT WATER SUPPLY
AutoCAD SHX Text
EXISTING PIPING
AutoCAD SHX Text
NATURAL GAS
AutoCAD SHX Text
MAKE UP WATER
AutoCAD SHX Text
BOILER FEED WATER
AutoCAD SHX Text
BOILER BLOW DOWN
AutoCAD SHX Text
HIGH PRESSURE STEAM
AutoCAD SHX Text
MEDIUM PRESSURE STEAM
AutoCAD SHX Text
LOW PRESSURE STEAM
AutoCAD SHX Text
HIGH PRESSURE CONDENSATE
AutoCAD SHX Text
LOW PRESSURE CONDENSATE
AutoCAD SHX Text
HFR
AutoCAD SHX Text
HFS
AutoCAD SHX Text
FOR
AutoCAD SHX Text
FOS
AutoCAD SHX Text
HG
AutoCAD SHX Text
(NAME)
AutoCAD SHX Text
LPG
AutoCAD SHX Text
G(NAME)
AutoCAD SHX Text
GHR
AutoCAD SHX Text
HWR
AutoCAD SHX Text
HWS
AutoCAD SHX Text
E(NAME)
AutoCAD SHX Text
G
AutoCAD SHX Text
MUW
AutoCAD SHX Text
BF
AutoCAD SHX Text
BBD
AutoCAD SHX Text
HPS
AutoCAD SHX Text
MPS
AutoCAD SHX Text
LPS
AutoCAD SHX Text
HPC
AutoCAD SHX Text
LPC
AutoCAD SHX Text
DN
AutoCAD SHX Text
UNION
AutoCAD SHX Text
FLOW METER ORIFICE
AutoCAD SHX Text
FLOW SWITCH
AutoCAD SHX Text
TEMPERATURE AND PRESSURE TEST PORT
AutoCAD SHX Text
PRESSURE SWITCH
AutoCAD SHX Text
PRESSURE REDUCING, SELF CONTAINED VALVE
AutoCAD SHX Text
PRESSURE REDUCING, EXTERNAL PRESSURE VALVE
AutoCAD SHX Text
BALL VALVE (PIPE SIZES 2" AND SMALLER) BUTTERFLY VALVE (PIPE SIZES 2-1/2" AND LARGER)
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
MOTOR OPERATED BUTTERFLY VALVE
AutoCAD SHX Text
GAS COCK
AutoCAD SHX Text
RELIEF VALVE
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
ATC VALVE - 2 WAY
AutoCAD SHX Text
ATC VALVE - 3 WAY
AutoCAD SHX Text
GLOBE VALVE
AutoCAD SHX Text
CALIBRATED BALANCING VALVE WITH GPM INDICATED
AutoCAD SHX Text
SHUT-OFF COCK FOR USE WITH PRESSURE GAUGE
AutoCAD SHX Text
FLOW METER
AutoCAD SHX Text
90° ELBOW
AutoCAD SHX Text
45° ELBOW
AutoCAD SHX Text
THERMOMETER - TEMP RANGE AS INDICATED
AutoCAD SHX Text
NIGHT THERMOSTAT
AutoCAD SHX Text
STEAM TRAP, F&T=FLOAT & THERMOSTATIC
AutoCAD SHX Text
B=BUCKET, T=THERMOSTATIC
AutoCAD SHX Text
ARROW INDICATES DIRECTION OF FLOW IN PIPE
AutoCAD SHX Text
LEADER INDICATES DOWNWARD SLOPE
AutoCAD SHX Text
RISER - DOWN (ELBOW)
AutoCAD SHX Text
RISER - UP (ELBOW)
AutoCAD SHX Text
BRANCH - SIDE CONNECTION
AutoCAD SHX Text
CLEAN-OUT
AutoCAD SHX Text
FLOOR CLEAN-OUT OR CLEAN-OUT TO GRADE
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text
DOMESTIC COLD WATER (DCW)
AutoCAD SHX Text
DOMESTIC HOT WATER (DHW)
AutoCAD SHX Text
DOMESTIC HOT WATER RETURN (DHWR)
AutoCAD SHX Text
PLUMBING FIXTURES
AutoCAD SHX Text
POINT OF CONNECTION
AutoCAD SHX Text
SECTION TAG - TOP FIGURE IS SECTION NO. BOTTOM FIGURE IS SHEET NO.
AutoCAD SHX Text
DETAIL TAG - TOP FIGURE IS DETAIL NO. BOTTOM FIGURE IS SHEET NO.
AutoCAD SHX Text
EQUIPMENT IDENTIFICATION
AutoCAD SHX Text
KEYED NOTE IDENTIFICATION
AutoCAD SHX Text
ACID WASTE
AutoCAD SHX Text
ACID VENT
AutoCAD SHX Text
HIGH PRESSURE DOMESTIC WATER
AutoCAD SHX Text
MEDICAL OXYGEN
AutoCAD SHX Text
MEDICAL AIR
AutoCAD SHX Text
MEDICAL AIR AT PRESSURE INDICATED
AutoCAD SHX Text
MEDICAL VACUUM
AutoCAD SHX Text
NITROGEN
AutoCAD SHX Text
NITROUS OXIDE
AutoCAD SHX Text
CARBON DIOXIDE
AutoCAD SHX Text
COMPRESSED AIR
AutoCAD SHX Text
LAB AIR
AutoCAD SHX Text
LAB VACUUM
AutoCAD SHX Text
BRINE
AutoCAD SHX Text
FIXTURE FROM LEVEL ABOVE
AutoCAD SHX Text
P-1
AutoCAD SHX Text
EF
AutoCAD SHX Text
1
AutoCAD SHX Text
OX
AutoCAD SHX Text
MA
AutoCAD SHX Text
MA 120
AutoCAD SHX Text
MV
AutoCAD SHX Text
N
AutoCAD SHX Text
C02
AutoCAD SHX Text
CA
AutoCAD SHX Text
LA
AutoCAD SHX Text
LV
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
M-101
AutoCAD SHX Text
A
AutoCAD SHX Text
M101
AutoCAD SHX Text
CONDENSER WATER RETURN
AutoCAD SHX Text
CONDENSER WATER SUPPLY
AutoCAD SHX Text
CHILLED WATER RETURN
AutoCAD SHX Text
CHILLED WATER SUPPLY
AutoCAD SHX Text
CR
AutoCAD SHX Text
CS
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
INSTRUMENT AIR
AutoCAD SHX Text
INSTRUMENT AIR AT PRESSURE INDICATED
AutoCAD SHX Text
IA
AutoCAD SHX Text
IA 120
AutoCAD SHX Text
MEDIUM PRESSURE CONDENSATE
AutoCAD SHX Text
MPC
AutoCAD SHX Text
BRANCH - BOTTOM CONNECTION
AutoCAD SHX Text
BRANCH - TOP CONNECTION
AutoCAD SHX Text
FLOOR SINK
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
AIR VENT-MANUAL
AutoCAD SHX Text
AIR VENT-AUTO
AutoCAD SHX Text
REDUCER
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
PIPE CAP
AutoCAD SHX Text
SWITCH
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
SENSOR
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
DOWNSPOUT NOZZLE
AutoCAD SHX Text
INLINE PUMP
AutoCAD SHX Text
INLINE PUMP
AutoCAD SHX Text
1
AutoCAD SHX Text
WATER HAMMER ARRESTOR
AutoCAD SHX Text
CONCENTRIC REDUCER
AutoCAD SHX Text
ECCENTRIC REDUCER
AutoCAD SHX Text
CEILING RETURN AIR GRILLE W/ SOUND BOOT
AutoCAD SHX Text
BDD
AutoCAD SHX Text
BACK DRAFT DAMPER
AutoCAD SHX Text
POSITIVE PRESSURE DUCT - RISE
AutoCAD SHX Text
POSITIVE PRESSURE DUCT - DROP
AutoCAD SHX Text
NEGATIVE PRESSURE DUCT - RISE
AutoCAD SHX Text
1-WAY BLOW PATTERN
AutoCAD SHX Text
2-WAY BLOW PATTERN
AutoCAD SHX Text
2-WAY BLOW PATTERN
AutoCAD SHX Text
3-WAY BLOW PATTERN
AutoCAD SHX Text
4-WAY BLOW PATTERN
AutoCAD SHX Text
DUCT SMOKE DETECTOR
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
SW
AutoCAD SHX Text
OX 120
AutoCAD SHX Text
REFRIGERANT SUCTION
AutoCAD SHX Text
REFRIGERANT LIQUID
AutoCAD SHX Text
PUMPED CONDENSATE
AutoCAD SHX Text
VACUUM
AutoCAD SHX Text
RS
AutoCAD SHX Text
RL
AutoCAD SHX Text
V
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
ROOF DRAIN OVERFLOW
AutoCAD SHX Text
SEWER (BELOW GRADE)
AutoCAD SHX Text
SEWER (ABOVE GRADE)
AutoCAD SHX Text
VENT (SEWER)
AutoCAD SHX Text
SOFT DOMESTIC WATER (SW)
AutoCAD SHX Text
REVERSE OSMOSIS WATER RETURN
AutoCAD SHX Text
MEDICAL OXYGEN AT PRESSURE INDICATED
AutoCAD SHX Text
RDO
AutoCAD SHX Text
RD
AutoCAD SHX Text
ROR
AutoCAD SHX Text
FCO
AutoCAD SHX Text
COTG
AutoCAD SHX Text
GATE VALVE - NON RISING STEM
AutoCAD SHX Text
ANGLE VALVE
AutoCAD SHX Text
BALANCING COCK
AutoCAD SHX Text
VALVE IN RISE
AutoCAD SHX Text
FILL PORT
AutoCAD SHX Text
DRAIN PAN AND P-TRAP
AutoCAD SHX Text
RISE OR DROP
AutoCAD SHX Text
DI
AutoCAD SHX Text
DEIONIZED WATER SUPPLY
AutoCAD SHX Text
DEIONIZED WATER RETURN
AutoCAD SHX Text
DIR
AutoCAD SHX Text
RO
AutoCAD SHX Text
REVERSE OSMOSIS WATER SUPPLY
AutoCAD SHX Text
FUEL OIL VENT
AutoCAD SHX Text
FOV
AutoCAD SHX Text
REDUCED PRESSURE BACKFLOW PREVENTOR W/ DRAIN PAN
AutoCAD SHX Text
LUBRICATED PLUG COCK
AutoCAD SHX Text
THERMOSTATIC MIXING VALVE
Page 21: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

1 2

B

A

SHOWER102

HSK101

WASH103

UTILITY SINK104

TOILET105

MECH106

HSK107

T

EF1

12"Ø310 (5)

12"Ø350 (2)

20/20 16/16

MAU11

MAINTENANCECLEARANCE

24/201450 (2)

20/20

14"Ø450 (2)

16/16

14"Ø500

20/20

UH1

16/16HOUSEKEEPING

PAD

30/14

16/16

TRANSITION DUCTWORKAS REQUIRED TO ENTER

EQUIPMENT STAND

14"Ø500 (2)

14"Ø500

14"Ø500

2

TMAU-1

3 3

M1.01

MECHANICAL PLANS

KEYED NOTES#

1. MOUNT MAKE-UP AIR UNIT ON MECHANICAL EQUIPMENTSTAND. SEE MECHANICAL DETAILS. FIELD VERIFY LOCATIONFOR MAKE-UP AIR UNIT TO BE PLACED DOES NOT CONFLICTWITH ANY UTILITIES, STRUCTURE, IRRIGATION EQUIPMENT,ETC. IF A CONFLICT IS DISCOVERED, IMMEDIATELY BRING TOTHE ATTENTION OF THE OWNER/ENGINEER FOR RESOLUTIONPRIOR TO ANY WORK PROGRESSING.

2. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS,DUCT SIZES, PIPE SIZES, LOCATIONS AND CONDITIONS PRIORTO BEGINNING ANY WORK OR PURCHASING ANY SUPPLIES OREQUIPMENT. IF ANY DISCREPANCIES, ERRORS, CONFLICTS ORCONCERNS ARE UNCOVERED THEY SHALL BE BROUGHT TOTHE ATTENTION OF THE OWNER/ENGINEER FOR RESOLUTIONPRIOR TO ANY WORK PROGRESSING.

3. CONCENTRIC VENT THRU ROOF.

SCALE: 1/4" = 1'-0"0' 4' 8'

02/14/2020

REG

I STE

RE

D PROFESS IONAL ENGIN

EER

No. 7715

S TA T E O F U TAH

RICHARD G.REEDER

181 East 5600 SouthMurray, Utah 84107O: (801) 530-3148www.vbfa.comvbfa project #: 18455

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

TD

ATE:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CAM

P W

ILLI

AMS

SHEETNO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UTAH

NAT

IONA

L GU

ARD

STAT

E OF

UTA

H DI

VISI

ON O

F FA

CILI

TIES

CON

STRU

CTIO

N AN

D M

ANAG

EMEN

T

OWNERSTATE OF UTAHDIVISION OF FACILITIESCONSTRUCTION AND MANAGEMENT4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 WBLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/14

/202

0 1:

33:5

4 PM

14 FEBRUARY 2020

22564.000

CONSTRUCTIONDOCUMENTS

BU

ILD

ING

414

1 R

EN

OV

AT

ION

S

1 MECHANICAL PLAN - BLDG 4141SCALE: M1.01

AutoCAD SHX Text
N
Page 22: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

W

INACCESIBLEDAMPER ISOPERATOR WHEREREMOTE CEILING

45

L=1/4 W (4" MIN.)NOTE:

L

REGULATORCEILING DAMPERPROVIDE CONCEALEDVOLUME DAMPER

AIR FLOW

INTERSECTIONSTO ELBOWS ORTHAN TWO DUCT WIDTHSBE INSTALLED CLOSERDAMPERS SHOULD NOTNOTE:

(MIN.)

(MIN.)(MIN.)(MIN.)DD

(MIN.)

30° ELBOW2 PIECE

45° ELBOW3 PIECE

60° ELBOW4 PIECE

90° ELBOW5 PIECE

DD

DDDDDD

11.25°

11.25

° 10°

10°

20°

20°

15°

15°

11.25°

22.5°

22.5°

22.5°

11.25

°

DUCT

TRUNK

DUCT

TRUNK

DUCT

TRUNK

TRUNK DUCT

AIR FLOW AIR FLOW

AIR FLOW

AIR FLOWBRANCH DUCT BRANCH DUCT

BRANCH DUCTBRANCH DUCT

90° CONICAL TEE

90° ELONGATED TEE

2-WAY 45° Y

45° Y TEE

SEE PLAN FOR

LOCATIONSIZE AND

NECK SIZE

GYPBOARD CEILING

SCREW MATING

MIN. OF TWO6" O.C. W/W/ SCREWS @COLLARS TIGHT

PER SIDE

1/2 DIFFUSER

2" MIN.

1"

DIFFUSER CONNECTIONBOOT LINED WITH 1"ACCOUSTICAL

BOX UP TO STRUCTURESTRAP EACH SIDE OFFOLDED SHEET METAL

PLANS FOR SIZE AND LOCATIONSUPPLY DIFFUSER OR REGISTER- SEE

WHEN REQUIRED

LAY-IN CEILING WHENREQUIRED

AT ALL EDGESMASTIC SEALANT

SUPPLY AIR

SHEET METAL DUCT

TO BOOT INLET COLLARSECURE FLEX DUCT

SEE PLANS FOR SIZE AND LOCATION

SUPPLY DIFFUSER-

INSULATION

CEILING SUPPORTCHANNEL

CEILING

SIZE

FLEX DUCTSEE PLAN FOR

ABOVEFROM STRUCTURESUPPORT FLEX DUCT

MAKE BEND RADIUS

TIGHTENING BAND1 1/2 x DUCT RADIUS

CEILING

DIFFUSER CONNECTION-AIS NOT ENOUGH ROOM FORFOR LOCATIONS WHERE THERENOTE:

RECTANGULAR DUCT SUPPORTNO SCALE

5

ROUND DUCT ELBOW DETAILSNO SCALE

3

BRANCH DUCT TAKE-OFF & DAMPER DETAILNO SCALE

7

DIFFUSER CONNECTION DETAIL - ANO SCALE

6DIFFUSER CONNECTION DETAIL - B11

DIFFUSER CONNECTION DETAIL - C10

ROUND DUCT BRANCH TAKE-OFF DETAILSNO SCALE

12

NO SCALE

NO SCALE

NO SCALEDUCT LINER DETAIL

METAL DUCTGALV. SHT.

OF LINER2" FROM EDGENOT MORE THAN

AND TAPED OVER.FIRMLY TOGETHERLINER SHALL BE BUTTEDADHESIVE. ENDS OFTO BE COATED WITHALL ENDS OF LINER

100% ADHESIVEDUCT WITHADHERED TOLINER TO BE

LINERDUCT

SIDESOVERLAP THELINER SHALLSECTION OFTOP AND BOTTOM

DUCT LINER

(TYP.)12" O.C. MAX.METAL FASTENERS

ROUND TRANSITIONRECTANGLE TO

VOLUME DAMPER AT EACH BRANCH TAKE-OFF

FLEX DUCT OR RIGID, SEE PLANS.

45°

AIR FLOW

RECTANGULAR DUCT

HIGH EFFICIENCY TAKE-OFF DETAILNO SCALE9

8

DUCT

BEND TAB UNDER

NOTE: USE SPECIFIED SPACING AND NOT LESS THAN ONE SUPPORT PER BRANCH.

1 1/4" x 16 GAUGESHEET METAL STRAP,TYPICAL

DOUBLE FOLD STRAP ANDSECURE TO TOP CHORD OF TRUSSES.

#10 SHEET METAL SCREW6" ON CENTER, TYP.

NO SCALE

MAKEUP AIR UNIT EQUIPMENT STAND DETAIL1

-

CENTRIFUGAL WALL EXHAUST FAN DETAILNO SCALE

2

FACTORYMOUNTINGBRACKET

ELECTRICUNIT HEATER

SUSPEND UNIT FROMSTRUCTURE W/1/2"DIAMETER STEEL RODSAND VIBRATION ISOLATORS

VIBRATION ISOLATOR

2- 1/2" X 2-1/2" X1/4" STEEL ANGLE(BOLTED TO BRACKET)

TOP OF UNIT TO BEMIN. OF 12" FROMALL STRUCTURE ORCEILING

ELECTRIC UNIT HEATER MOUNTING DETAILNO SCALE4

02/14/2020

REG

ISTE

RE

D PROFESS IONAL ENGIN

EER

No. 7715

S TA T E O F U TAH

RICHARD G.REEDER

181 East 5600 SouthMurray, Utah 84107O: (801) 530-3148www.vbfa.comvbfa project #: 18455

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

TD

ATE:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CAM

P W

ILLI

AMS

SHEETNO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UTAH

NAT

IONA

L GU

ARD

STAT

E OF

UTA

H DI

VISI

ON O

F FA

CILI

TIES

CON

STRU

CTIO

N AN

D M

ANAG

EMEN

T

OWNERSTATE OF UTAHDIVISION OF FACILITIESCONSTRUCTION AND MANAGEMENT4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 WBLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/14

/202

0 1:

33:5

4 PM

14 FEBRUARY 2020

22564.000

CONSTRUCTIONDOCUMENTS

BU

ILD

ING

414

1 R

EN

OV

AT

ION

S

M5.01

MECHANICALDETAILS &SCHEDULES

ELECTRIC UNIT HEATER SCHEDULEAIR ELECTRICAL PHYSICAL

ENTERING LEAVINGAIRFLOW TEMP. TEMP.

AREA RATE LOAD DB DB WEIGHTID MANUFACTURER MODEL NUMBER SERVED TYPE (CFM) (BTU/H) (°F) (°F) KW AMPS VOLT/PH/HZ W x D x H (IN) (LBS) NOTES

UH-1 MARKEL HF2B5103N SEE PLANS HORIZONTAL 300 8,500 60 86 2.5 6.9 208/1/60 14.5 x 6.5 x 18 30 1,2

1. PROVIDE WITH LOUVER DIFFUSER, FACTORY MOUNTED THERMOSTAT (SET TO 60° F), MOUNTING KIT, HEATER BRACKETS AND DISCONNECT (DISCONNECT TO BE INSTALLED BY DIVISION 26).2. SCHEDULED CAPACITIES AT AHRI CONDITIONS.

FAN SCHEDULEAIR ELECTRICAL PHSICAL

MAXIMUMAIRFLOW STATIC MOTOR MOTOR MOTOR

AIR RATE PRESSURE SIZE SIZE SPEED SONES DIMENSIONS WEIGHTID MANUFACTURER MODEL NUMBER TYPE TYPE (CFM) (IN. WATER) (BHP) (HP) (RPM) VOLT/PH DIA" x H" (LB) NOTES

EF-1 COOK ACWD 195W17D (VF2) UPBLAST, WALL EXHAUST 2,750 0.35 0.303 3/4 1725 208/3 7.6 40"Ø x 36.5" 80 1,2,3,4

1. DIRECT DRIVE, CENTRIFUGAL EXHAUST FAN; PROVIDE WITH BIRD SCREEN, BACKDRAFT DAMPER AND DISCONNECT (DISCONNECT INSTALLED BY DIV. 26).2. PROVIDE WITH ECM WIRING PACKAGE OR 0-10VDC CONTROL FOR EXHAUST EC MOTORS. CONTROLS PROVIDED TO BE COMPATIBLE WITH CAMP WILLIAMS MANAGEMENT SYSTEM.3. FAN TO RUN CONTINUOUSLY WHEN BUILDING IS OCCUPIED.4. SCHEDULED CAPACITIES AT 4,800 FEET ELEVATION.

GRILLES, REGISTERS AND DIFFUSERS

ID MANUFACTURER MODEL DESCRIPTION

CD-1 PRICE SPD

FACE STYLE: SQUARE PLAQUE DIFFUSER W/ REMOVABLE FACE FINISH: COORDINATE COLOR WITH ARCHITECTFACE SIZE: 24" x 24". MOUNTING-FRAME: SURFACE OR LAY-IN, AS REQ'D.

APPLICATION: SUPPLY AIR PATTERN: 360° RADIAL HORIZONTAL AIR PATTERNVELOCITY: 500 FPM MAX DAMPER: OPPOSED BLADEMATERIAL: ALUMINUM / STEEL MAX NC - 30

EG-1 PRICE PDDRE

FACE STYLE: PERFORATED. MOUNTING-FRAME: SURFACE W/ REMOVABLE FACE & CORE.FACE SIZE: 16" x 16" DAMPER: OPPOSED BLADEAPPLICATION: EXHAUST AIR FINISH: COORDINATE COLOR WITH ARCHITECTMATERIAL: ALUMINUM / STEEL MAX NC - 30

RG-1 PRICE 10

FACE STYLE: PERFORATED W/ 1/2" x 1/2" x 1/2" SQUARES. MOUNTING-FRAME: SURFACE W/ REMOVABLE FACE & CORE.FACE SIZE 22" x 20" DAMPER: OPPOSED BLADEAPPLICATION: RETURN AIR FINISH: COORDINATE COLOR WITH ARCHITECTMATERIAL: ALUMINUM / STEEL MAX NC - 30

NOTE: UNLESS NOTED OTHERWISE CD-1 TYPICAL SQUARE DIFFUSER; RG-1 TYPICAL SQUARE RETURN AIR GRILLE; EG-1 TYPICAL EXHAUST AIR GRILLE

MAKE-UP AIR UNIT SCHEDULEEVAPORATIVE COOLING HEATING MOTOR

TOTAL ENTER/ DOMESTICOUTSIDE STATIC ENTERING LEAVING LEAVING COLDAIR FLOW PRESSURE AIR TEMP. AIR TEMP. AIR TEMP. HEATING HEATING SUPPLY WATER

RATE DROP DB / WB DB / WB DB LOAD INPUT LOAD OUTPUT WORKING FAN CONNECTIONID MANUFACTURER MODEL NUMBER LOCATION (CFM) (IN H20) (DEG. F) (DEG. F) EFFICIENCY (DEG. F) (MBH) (MBH) FLUID HP FLA V/PH DIA. (IN) WEIGHT (LBS) NOTES

MAU-1 TRANE GRAA35GDJF0 GROUND 2800 1 99 / 63 64 / 62 90% 0 / 95 350 247.79 NATURAL GAS 1.5 - 208/3 3/4 1200 1,2,3

1. PROVIDE WITH STAINLESS STEEL BURNER, THERMOSTAT, (4) 2" MERV-8 FILTERS, 42-INCH INSULATED EQUIPMENT STAND W/ SIDE RETURN INLET, MODULATING GAS HEAT, INTEGRAL 2-POSITION OSA & RETURN DAMPER(S), EVAPORATIVE COOLING SECTION, AND MANUFACTURER'S NON-FUSED DISCONNECT (DISCONNECT TO BE INSTALLED BY DIV. 26,ELECTRICIAN).2. SCHEDULED CAPACITIES AT 4,800 FEET ELEVATION.

3. CONTROLS TO BE COMPATIBLE WITH CAMP WILLIAMS' MANAGEMENT SYSTEM.

AutoCAD SHX Text
1.
AutoCAD SHX Text
2.
AutoCAD SHX Text
%%uNOTES%%u:
AutoCAD SHX Text
MAU
AutoCAD SHX Text
O.A. FACTORY HOOD
AutoCAD SHX Text
PROVIDE RESILIENT CAULKING (TYPICAL)
AutoCAD SHX Text
SEE FLOOR PLANS FOR DUCT SIZES
AutoCAD SHX Text
TRANSITION DUCTS AS REQUIRED (TYP.)
AutoCAD SHX Text
42" HIGH, HORIZONTAL SIDE RETURN TYPE FACTORY INSULATED EQUIPMENT STAND.
AutoCAD SHX Text
COORDINATE EXACT LOCATION OF STAND WITH ARCHITECT / OWNER.
AutoCAD SHX Text
DUCTWORK EXPOSED TO THE ELEMENTS TO BE INSULATED.
AutoCAD SHX Text
%%uNOTE:
AutoCAD SHX Text
INSTALLATION PROCEDURES
AutoCAD SHX Text
WITH MANUFACTURERS
AutoCAD SHX Text
WALL IN ACCORDANCE
AutoCAD SHX Text
MOUNT AND SECURE TO
AutoCAD SHX Text
DAMPER
AutoCAD SHX Text
BACKDRAFT
AutoCAD SHX Text
POST
AutoCAD SHX Text
INTERNAL WIRING
AutoCAD SHX Text
SWITCH
AutoCAD SHX Text
SAFETY DISCONNECT
AutoCAD SHX Text
FAN
AutoCAD SHX Text
WALL EXHAUST
AutoCAD SHX Text
CENTRIFUGAL
AutoCAD SHX Text
BIRDSCREEN
AutoCAD SHX Text
CAULK / SEAL WEATHER TIGHT
AutoCAD SHX Text
EXTERIOR WALL
AutoCAD SHX Text
GRAVITY
AutoCAD SHX Text
6-INCH THICK CONCRETE PAD
AutoCAD SHX Text
RETURN AIR DUCT
AutoCAD SHX Text
SUPPLY AIR DUCT
AutoCAD SHX Text
FLEXIBLE CONNECTION
Page 23: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

SHOWER102

HSK101

WASH103

UTILITY SINK104

TOILET105

MECH106

HSK107

SHOWER102

HSK101

WASH103

UTILITY SINK104

TOILET105

MECH106

HSK107

02/14/2020

REG

I STE

RE

D PROFESS IONAL ENGIN

EER

No. 7715

S TA T E O F U TAH

RICHARD G.REEDER

181 East 5600 SouthMurray, Utah 84107O: (801) 530-3148www.vbfa.comvbfa project #: 18455

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

TD

ATE:

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

ISSUE

© 2005 HKS, INC.

CAM

P W

ILLI

AMS

SHEETNO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UTAH

NAT

IONA

L GU

ARD

STAT

E OF

UTA

H DI

VISI

ON O

F FA

CILI

TIES

CON

STRU

CTIO

N AN

D M

ANAG

EMEN

T

OWNERSTATE OF UTAHDIVISION OF FACILITIESCONSTRUCTION AND MANAGEMENT4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 WBLUFFDALE, UT 84065

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

2/14

/202

0 1:

33:5

4 PM

14 FEBRUARY 2020

22564.000

CONSTRUCTIONDOCUMENTS

BU

ILD

ING

414

1 R

EN

OV

AT

ION

S

P1.01

PLUMBINGPLANS

KEYED NOTES#

P101 SCALE: 1/4" = 1'-0"0' 4' 8'

PLUMBING PLAN - WASTE & VENT - BLDG. 4141SCALE:

P101 SCALE: 1/4" = 1'-0"0' 4' 8'

PLUMBING PLAN - WATER & GAS - BLDG. 4141SCALE:

1

2

AutoCAD SHX Text
EXISTING 6-INCH WASTE SERVING BUILDING 4140. FIELD VERIFY EXACT SIZE & LOCATION.
AutoCAD SHX Text
WYOMING AVE.
AutoCAD SHX Text
EXISTING 8"WASTE
AutoCAD SHX Text
2
AutoCAD SHX Text
SS-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
U-1
AutoCAD SHX Text
U-1
AutoCAD SHX Text
U-1
AutoCAD SHX Text
U-1
AutoCAD SHX Text
U-1
AutoCAD SHX Text
L-1
AutoCAD SHX Text
L-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
4"WASTE
AutoCAD SHX Text
8
AutoCAD SHX Text
I.E. 97.1'
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
F.F.E. 100'-0"
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WCO
AutoCAD SHX Text
FD-2
AutoCAD SHX Text
FD-2
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
U-1
AutoCAD SHX Text
U-1
AutoCAD SHX Text
FCO
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
4" VTRVTR
AutoCAD SHX Text
4" VTRVTR
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
12
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
3"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
3"
AutoCAD SHX Text
4"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
%%UCOTG
AutoCAD SHX Text
2
AutoCAD SHX Text
L-1
AutoCAD SHX Text
L-1
AutoCAD SHX Text
L-1
AutoCAD SHX Text
L-1
AutoCAD SHX Text
L-1
AutoCAD SHX Text
L-1
AutoCAD SHX Text
L-1
AutoCAD SHX Text
2"
AutoCAD SHX Text
S-1
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WCO
AutoCAD SHX Text
U-1
AutoCAD SHX Text
U-1
AutoCAD SHX Text
U-1
AutoCAD SHX Text
FD-2
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
4"
AutoCAD SHX Text
3"
AutoCAD SHX Text
3"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
3"
AutoCAD SHX Text
3"
AutoCAD SHX Text
3"
AutoCAD SHX Text
4"
AutoCAD SHX Text
G
AutoCAD SHX Text
7
AutoCAD SHX Text
7
AutoCAD SHX Text
DHWR
AutoCAD SHX Text
HB-1
AutoCAD SHX Text
DCW
AutoCAD SHX Text
DHW
AutoCAD SHX Text
4
AutoCAD SHX Text
(9)
AutoCAD SHX Text
8
AutoCAD SHX Text
1"
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
1"
AutoCAD SHX Text
1"
AutoCAD SHX Text
1-1/4"
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
1"
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
2"
AutoCAD SHX Text
1"
AutoCAD SHX Text
1 1/4"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
1 1/4"
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
1"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
1"
AutoCAD SHX Text
2 1/2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
1"
AutoCAD SHX Text
2"
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
2"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
2 1/2"
AutoCAD SHX Text
1"
AutoCAD SHX Text
2 1/2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
3"
AutoCAD SHX Text
EXISTING 3/4" GAS BELOW GRADE
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM-1
AutoCAD SHX Text
6
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
1 1/4"
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
2"
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
1"
AutoCAD SHX Text
5
AutoCAD SHX Text
2-1/2"DCW
AutoCAD SHX Text
VERTICAL PRV, SEE PLUMBING DETAILS.
AutoCAD SHX Text
GM
AutoCAD SHX Text
GM-1
AutoCAD SHX Text
1
AutoCAD SHX Text
MECHANICAL EQUIPMENT, SEE MECHANICAL PLANS
AutoCAD SHX Text
MAU
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
9
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
1-1/4"
AutoCAD SHX Text
1"
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
2"
AutoCAD SHX Text
2-1/2"
AutoCAD SHX Text
1"
AutoCAD SHX Text
2 1/2"
AutoCAD SHX Text
1"
AutoCAD SHX Text
3"
AutoCAD SHX Text
2"
AutoCAD SHX Text
EXISTING 2-1/2"DCW BELOW GRADE
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
MECHANICAL EQUIPMENT, SEE MECHANICAL PLANS
AutoCAD SHX Text
11
AutoCAD SHX Text
WH-199
AutoCAD SHX Text
1
AutoCAD SHX Text
WH-199
AutoCAD SHX Text
2
AutoCAD SHX Text
N
AutoCAD SHX Text
N
AutoCAD SHX Text
1. DOMESTIC COLD WATER, DOMESTIC HOT WATER & DOMESTIC COLD WATER, DOMESTIC HOT WATER & DOMESTIC HOT WATER RE-CIRCULATION PIPING UP TO ABOVE CEILING. 2. FIELD VERIFY EXISTING WASTE FROM BUILDING 4141 TIES FIELD VERIFY EXISTING WASTE FROM BUILDING 4141 TIES INTO EXISTING 6-INCH WASTE SERVING BARRACKS 4140. IF SO, CONNECT NEW 4-INCH WASTE TO EXISTING 6-INCH WASTE SERVING BUILDING 4140. IF NOT, ROUTE NEW 4-INCH WASTE TO POINT OF CONNECTION AT STREET, AS SHOWN ON PLANS. IF REQUIRED, FIELD VERIFY EXACT LOCATION OF EXISTING 8-INCH MAIN AT STREET. FIELD VERIFY LOCATION AND DEPTHS OF OTHER EXISTING UTILITIES PRIOR TO EXCAVATION. 3. PROVIDE GAS SHUT-OFF VALVE AND PRESSURE PROVIDE GAS SHUT-OFF VALVE AND PRESSURE REGULATOR AT MECHANICAL EQUIPMENT CONNECTION. VERIFY REQUIREMENTS, PRESSURE AND PIPE SIZE WITH MANUFACTURER'S SPECIFICATION AND INSTRUCTIONS. 4. DOMESTIC WATER PIPING DOWN IN FURRED WALL. ROUTE DOMESTIC WATER PIPING DOWN IN FURRED WALL. ROUTE WATER PIPING ON THE INSIDE OF EXTERIOR WALL INSULATION. 5. PROVIDE AND INSTALL 2 PSI, 1070 CFH GAS METER, PROVIDE AND INSTALL 2 PSI, 1070 CFH GAS METER, SEE PLUMBING DETAILS & PLUMBING FIXTURE SCHEDULE. FIELD VERIFY GAS INLET PRESSURE IS MAXIMUM 100 PSI. IF HIGHER, INFORM ARCHITECT / ENGINEER AND AWAIT RESOLUTION PRIOR TO WORK PROGRESSING. 6. INSTALL NEW WATER METER IN ACCESSIBLE LOCATION INSTALL NEW WATER METER IN ACCESSIBLE LOCATION BELOW CEILING OF MECHANICAL ROOM. WATER METER TO BE INTEGRATED WITH CAMPUS UTILITY USAGE MONITORING SYSTEM. 7. DOMESTIC HOT WATER DOWN IN WALL FOR SERVICE TO DOMESTIC HOT WATER DOWN IN WALL FOR SERVICE TO PUBLIC LAV(S) THEN BACK UP TO ABOVE CEILING. 8. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, DUCT SIZES, PIPE SIZES, LOCATIONS AND CONDITIONS PRIOR TO BEGINNING ANY WORK OR PURCHASING ANY SUPPLIES OR EQUIPMENT. IF ANY DISCREPANCIES, ERRORS, CONFLICTS OR CONCERNS ARE UNCOVERED THEY SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER/ENGINEER FOR RESOLUTION PRIOR TO ANY WORK PROGRESSING. 9. 2-INCH DCW AND 2-INCH DHW DOWN FOR CONNECTION 2-INCH DCW AND 2-INCH DHW DOWN FOR CONNECTION TO HOT WATER HEATER. SEE GAS FIRED HOT WATER HEATER DETAIL. PROVIDE SHUT-OFF VALVE AND GAS PRESSURE REGULATOR AT EQUIPMENT GAS CONNECTION. 10. PROVIDE SHUT-OFF VALVE AND DRAIN VALVE FOR PROVIDE SHUT-OFF VALVE AND DRAIN VALVE FOR WINTERIZING MAU EVAPORATIVE COIL. IF REQUIRED, PROVIDE ARCHITECT APPROVED ACCESS PANEL. 11. CAP 3/4-INCH GAS STUB-OUT FOR FUTURE CAP 3/4-INCH GAS STUB-OUT FOR FUTURE CONNECTION TO ADDITIONAL WATER HEATER. 12. EXISTING UTILITIES ROUTED PARALLEL TO AND BELOW EXISTING UTILITIES ROUTED PARALLEL TO AND BELOW STREET. IF REQUIRED, VERIFY EXACT LOCATION WITH BLUE STAKES BEFORE DIGGING.
Page 24: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r
Page 25: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

OAKESON

JOSHUA

No. 7707671-2202

GIN

EER

ONA

OF

ESSI

R

UTAH

TE OF

STA

P

L EN

2018 BNA CONSULTING SA

LT L

AK

E

ST.G

EO

RG

ESuite 202St. George, Utah 84770

CONSULTING

P:435.628.3670F:435.628.3680

www.bnaconsulting.com

393 East Riverside Drive

BNA

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

2/1

3/2

020

10:1

3:3

7 P

M

E0.01

SYMBOLS, SCHEDULES

AND NOTES

29 JANUARY 2019

22564.000

For Information Only

SHEET INDEXSHEET INDEXSHEET INDEXSHEET INDEXE0.01 SYMBOLS, SCHEDULES AND NOTES

E0.02 SCHEDULES

E2.01 LIGHTING PLAN

E3.01 POWER AND SYSTEMS PLAN

842

TC

J

P

F

S

F

H

S

D

D

R

CM

D

ML

CR

34EQ

A

H

MM

S

1D

2D

A

I

M

ES

T

A

PP

S

S

S

S

S

S

S

C

S

SEE DIAGRAM,SPECIFICATION

EQUIPMENT CABINET/RACK CIRCUIT TO 120V

ARCHITECTURAL ROOM NUMBER

TIME CLOCK +5'-0" 2.

JUNCTION BOX ('F' IN FLOOR) AS NOTED

MOTOR OUTLETEQUIP.

TO SUIT

PHOTO-ELECTRIC CONTROL TORK 2000AAS NOTED

PUSHBUTTON +4'-0" 6.

NON-FUSED DISCONNECT SWITCH +5'-0" 5.

FUSED DISCONNECT SWITCH +5'-0" 5.

MANUAL STARTER THERMAL OVERLOAD SWITCH WITH PILOT LIGHT

T+4'-0" 2.

VARIABLE FREQUENCY DRIVEVFD +6'-6"

MAGNETIC STARTER / DISCONNECT COMBINATION +5'-0"

PANEL BOARDTOP AT+6'-0"

MAIN DISTRIBUTION PANEL

TELEPHONE TERMINAL BOARD

FIRE ALARM MANUAL STATION +4'-0" 6.

FIRE ALARM SIGNAL HORN/STROBE 6.

SMOKE DETECTOR CEILING

DUCT SMOKE DETECTOR MTD. IN DUCT

FIRE/SMOKE DAMPER

DOOR HOLDER AS NOTED

ST TAMPER SWITCH

FIRE ALARM RELAY OR SECURITY RELAY

FIRE ALARM CONTROL MODULE

DURESS PUSHBUTTON +4'-0"

MAGNETIC SHEAR LOCK

ACCESS CONTROL CARD READER +4'-0" 6.

CAMERA - SEE SCHEDULE AS NOTED

EQUIPMENT NUMBER

LIGHT FIXTURE (LETTER DESIGNATES TYPE)

BELL +7'-6"

HEAT DETECTOR CEILING

SF FLOW SWITCH

FW WATER FLOOD INDICATOR

FIRE ALARM MONITOR MODULE

FIRE ALARM STROBE

SECURITY SYSTEM DOOR SWITCHDOORJAMB

MOUNT AS PER. MFR.

SECURITY SYSTEM OVERHEAD DOOR SWITCH CEILING

SECURITY SYSTEM KEYED ACCESS SWITCH +4'-0" 6.

INFRARED SENSOR AS NOTED

MOUNT AS PER. MFR.

SECURITY MOTION DETECTOR

ELECTRIC DOOR STRIKE

DOOR POSITION INDICATING SWITCH

O.S. & Y. VALVE SEE DIAGRAM

LOW VOLTAGE TRANSFORMER

CORD DROP SEE DIAGRAM

AUTOMATIC RELAY PACK CEILINGSEE DIAGRAM. SPEC.

POWER PACK CEILINGSEE DIAGRAM, SPEC.

CALL SWITCH +4'-0" 6.

PLUGMOLD+46" OR

AS NOTED

SPECIAL PURPOSE OUTLET 10. WITH CAP. 11.AS NOTED+16" OR

MOMENTARY CONTACT SWITCH, CENTER POSITION OFF +4'-0" 6.

TIMER SWITCH +4'-0" 6.TM

PSWITCH WITH PILOT LIGHT +4'-0" 6.

K KEY OPERATED SWITCH +4'-0" 6.

4 FOUR-WAY SWITCH +4'-0" 6.

3 THREE-WAY SWITCH +4'-0" 6.

x6. 4.SINGLE POLE SWITCH +4'-0"

AS NOTEDCEILING/WALL MOUNTED EXIT LIGHTCEILING/

1.3.8.

FLOOD OR TRACK FIXTURE AS NOTED

EGRESS LIGHT FIXTURE AS NOTED UNSWITCHED

LIGHT FIXTURE AS NOTED 1

RECESSED DOWNLIGHT FIXTURE CEILING 1.

WALL LIGHT FIXTURE AS NOTED 1.

CEILING LIGHT FIXTURE CEILING 1.

CABLE TRAY AS NOTED

CONDUIT STUB LOCATION CONDUITCAP

CONDUIT DOWN

CONDUIT UP

CONDUIT RUN CONCEALED IN FLOOR OR GROUND

CONDUIT RUN CONCEALED IN WALL OR CEILING

3 CIRCUIT, HOME RUN TO PANEL

2 CIRCUIT, HOME RUN TO PANEL

ONE CIRCUIT, HOME RUN TO PANEL CLOCK OUTLET +7'-6" 8.

ELECTRIC WATER COOLER RECEPTACLEWSEE DIAGRAM

A DUPLEX RECEPTACLE 9.

+4'-0" 6.CEILING/WALL MOUNTED OCCUPANCY SENSOR CEILING/

BASEAREA LIGHT POLE AND FIXTURE CONCRETE SEE DIAGRAM

VARIABLE INTENSITY SWITCH +4'-0" 6.D

DUPLEX RECEPTACLE 9. 11.AS NOTED+16" OR

WEATHERPROOF RECEPTACLEWP 2. 9.AS NOTED+24" OR

GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE 9. 11.AS NOTED+16" OR

DUPLEX RECEPTACLE EMERGENCY POWER (RED) 9. 11.AS NOTED+16" OR

FOURPLEX RECEPTACLE 9. 11.AS NOTED+16" OR

FOURPLEX RECEPTACLE EMERGENCY POWER (RED) 9. 11.AS NOTED+16" OR

TELEVISION OUTLET 11.AS NOTED+16" OR

LOW VOLTAGE WALLSTATION (SUBSCRIPT INDICATES +4'-0"CONFIGURATION & CONTROL SEQUENCE) SEE DIAGRAM

ELECTRICAL SYMBOL SCHEDULEELECTRICAL SYMBOL SCHEDULEELECTRICAL SYMBOL SCHEDULEELECTRICAL SYMBOL SCHEDULE

NOTESNOTESNOTESNOTESMOUNTING MOUNTING MOUNTING MOUNTING

HEIGHTHEIGHTHEIGHTHEIGHTDESCRIPTIONDESCRIPTIONDESCRIPTIONDESCRIPTIONSYMBOLSYMBOLSYMBOLSYMBOL

STANDARD MOUNTING HEIGHT UNLESS OTHERWISE NOTED ON PLANSSTANDARD MOUNTING HEIGHT UNLESS OTHERWISE NOTED ON PLANSSTANDARD MOUNTING HEIGHT UNLESS OTHERWISE NOTED ON PLANSSTANDARD MOUNTING HEIGHT UNLESS OTHERWISE NOTED ON PLANS

1. SEE FIXTURE SCHEDULE FOR TYPE, MOUNTING AND WATTAGE.2. HEIGHT MEASURED TO CENTER LINE OF THE BOX FROM THE FINISH FLOOR.3. REFER TO DRAWINGS FOR DIRECTIONAL ARROWS.4. SUBSCRIPT KEYS SWITCH TO FIXTURES CONTROLLED.5. NEMA TYPE 'ND' NON-FUSED UNLESS NOTED 'F' (FUSED). USE 'HD' 480 V.6. HEIGHT MEASURED TO TOP OF THE BOX FROM FINISH FLOOR.

NOTESNOTESNOTESNOTESMOUNTING MOUNTING MOUNTING MOUNTING

HEIGHTHEIGHTHEIGHTHEIGHTDESCRIPTIONDESCRIPTIONDESCRIPTIONDESCRIPTIONSYMBOLSYMBOLSYMBOLSYMBOL

7. PROVIDE H.O.A. AND S.S. PUSHBUTTONS AS REQUIRED.8. DOUBLE ARROWS DENOTE A DOUBLE FACE UNIT.9. COORDINATE WITH MILLWORK SHOP DRAWINGS AND ELEVATIONS FOR HEIGHT.10. SUBSCRIPT DENOTES NEMA CONFIGURATION.11. HEIGHT MEASURED TO BOTTOM OF THE BOX FROM FINISH FLOOR.12. COORDINATE WITH DOOR HARDWARE SUPPLIER.

RECESSED WALLWASH DOWNLIGHT FIXTURE CEILING 1.

WIRELESS ACCESS POINT, TWO CABLES CEILING

FT FLIP-TOP BOX

TOMBSTONE RECEPTACLE

DIGITAL DAYLIGHT SENSOR CEILING

VASPIRATING SMOKE DETECTION SYSTEM CEILING MOUNT AS

PER. MFR.

UPPER OUTLETSWITCH CONTROLLEDDUPLEX RECEPTACLE 9. 11.AS NOTED

+16" OR

SIMPLEX RECEPTACLE 9. 11.AS NOTED+16" OR

ISOLATED GROUND RECEPTACLEIG 2. 9.AS NOTED+16" OR

DATA OUTLET, ONE CABLE 9. 11.AS NOTED

DATA OUTLET, TWO CABLES 9. 11.AS NOTED+16" OR

DATA OUTLET, THREE CABLES 9. 11.+16" OR

PT POKE THRU - SEE SCHEDULE FLOOR

9.

MAGNETIC STARTER +5'-0" 7.

CHIME +7'-6"

E FIRE ALARM SIGNAL SPEAKER/STROBE 6.

K FIRE ALARM SPEAKER ONLY 6.

G GLASS BREAK DETECTOR CEILING

+16" OR

AS NOTED

12.

EL ELECTRIC DOOR LOCK 12.

GROUND FAULT INTERRUPTER FOURPLEX RECEPTACLE 9. 11.AS NOTED+16" OR

R ACCESS CONTROL SYSTEM, REQUEST TO EXIT

K SECURITY SYSTEM KEYPAD +4'-0" 6.

POWER POLE

RCDIGITAL ROOM CONTROLLER (SUBSCRIPT INDICATES NUMBER OF RELAYS) CEILING

SEE DIAGRAM, SPEC.X

CONDUIT/CIRCUIT CONTINUATION

TVSS PROTECTED RECEPTACLE 9. 11.AS NOTED+16" OR

DATA OUTLET, W/MORE THAN (3) CABLES 9. 11.+16" OR

AS NOTEDX

CORD REEL SEE DIAGRAM

H CONCEALED FIRE ALARM SIGNAL HORN/STROBE

E CONCEALED FIRE ALARM SIGNAL SPEAKER/STROBE

S CONCEALED FIRE ALARM SIGNAL STROBE

SCSMOKE/CARBON MONOXIDE DETECTOR

CCARBON MONOXIDE DETECTOR

CEILING

CEILING

BR ACCESS CONTROL BIOMETRIC READER +4'-0" 6.

TW TWO-WAY COMMUNICATION SYSTEM CALL STATION

TWZTWO-WAY COMMUNICATION SYSTEM ANNUNCIATOR

DUPLEX RECEPTACLE WITH USB OUTLET 9. 11.AS NOTEDU+16" OR

SIMPLEX RECEPTACLE WITH USB OUTLET 9. 11.AS NOTED+16" OR

U

GROUND BUS BAR

+4'-0"

+4'-0" 6.

6.PANEL

SUBSCIPT A=ANALOG, D = DIGITAL

9. 11.AS NOTED+16" OR

CONTROLLED RECEPTACLE

RECEPTACLE SWITCH PACK CEILINGR

B FIRE ALARM SIGNAL STROBE WITHBLUE COLORED LENS (CO VISUAL ALARM) +8'-0"

CEILING/ MOUNT AS PER. MFR.

EPABOVE

CEILINGSEE DIAGRAM, SPEC.

EMERGENCY LIGHTING CONTROL UNIT

+8'-0"

S CONCEALED FIRE ALARM SIGNAL STROBE WALL 6.+8'-0"

CLG CEILING

6.+8'-0"

ECONCEALED FIRE ALARM SIGNAL SPEAKER/STROBE WALL

6.+8'-0"

CLG CEILING

+8'-0"

H 6.+8'-0"CONCEALED FIRE ALARM SIGNAL HORN/STROBE WALL

CLG CEILING

+7'-6"

X6., SEE DIAGRAM, SPEC.

FB FLOOR BOX - SEE SCHEDULE FLOORSEE DIAGRAM,SPEC.SEE DIAGRAM,SPEC.

SEE DIAGRAM,SPEC.

DEVICE/EQUIPMENT (TEXT DESIGNATES TYPE) SEE SCHEDULE

PMOUNT AS PER. MFR.

SECURITY SYSTEM POP-IT

DP

CP CEILING PROJECTION SYSTEM CEILING BOX

FLAT PANEL DISPLAY WALL BOX TVSS RECEPT., SEE DIAGRAM,SPEC. 26 2726SEE DIAGRAM,SPEC.

AS NOTED

CEILINGABOVE

ABBREV. DESCRIPTION ABBREV. DESCRIPTION

ABBREVIATIONS INDEX

# NUMBER

AC ALTERNATING CURRENT

A.F.F. ABOVE FINISH FLOOR

AIC AMPS INTERRUPTING CAPACITY

AM AMPS METER

AMP AMPERE

ANN ANNUNCIATOR

ATS AUTOMATIC TRANSFER SWITCH

AUX AUXILIARY

AWG AMERICAN WIRE GAUGE

BC BARE COPPER

BFG BELOW FINISH GRADE

C CONDUIT

CAB CABINET

CATB COMMUNITY ANTENNA TELEVISION

CATV CABLE TELEVISION

CKT CIRCUIT

CLG CEILING

CNTR CONTRACTOR

C.O. CONDUIT ONLY

CRT COMPUTER TERMINAL

CT CURRENT TRANSFORMER

CU COPPER

C/W COMPLETE WITH

DB DECIBEL

DC DIRECT CURRENT

DWG DRAWING

(E) EXISTING

EC EMPTY CONDUIT

EG EMERGENCY GENERATOR

EMT ELECTRICAL METALLIC TUBING

EX EXPLOSION PROOF

FACP FIRE ALARM CONTROL PANEL

FC FOOT CANDLE

FT FOOT

GFI GROUND FAULT INTERRUPTER

GND GROUND

GRC GALVANIZED RIGID CONDUIT

HP HORSE POWER

HZ HERTZ

IG ISOLATED GROUND

IMC INTERMEDIATE METALLIC CONDUIT

IN INCH

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT AMPERES

KVAR KILOVARS

KW KILOWATT

LRA LOCKED ROTOR AMPS

LTG LIGHTING

MNF MANUFACTURER

MATV MASTER ANTENNA TELEVISION

MAX MAXIMUM

MB MAIN BUS

MCC MOTOR CONTROL CENTER

MCM 1000 CIRCULAR MILLS

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MTG MOUNTING

MTR MOTOR

N/A NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECT. MANUFAC. ASSOC.

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION ASSOC.

N.I.C. NOT IN CONTRACT

NO NORMALLY OPENED

NTS NOT TO SCALE

OS & Y OUTSIDE SCREW & YOKE

PB PUSHBUTTON

PF POWER FACTOR

PFR PHASE FAILURE RELAY

PNL PANEL

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE CONDUIT

(R) RELOCATE

RECEP RECEPTACLE

REQ REQUIREMENT

RLA RATED LOAD AMPS

RMS ROOT MEAN SQUARE

SE SERVICE ENTRANCE

SPEC SPECIFICATIONS

SPKR SPEAKER

SS SELECTOR SWITCH

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

TTB TELEPHONE TERMINAL BOARD

TTC TELEPHONE TERMINAL CABINET

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

UP UTAH POWER

UPS UNINTERRUPTED POWER SUPPLY

V VOLT (KV-KILOVOLT)

VA/R VOLT-AMPS/REACTIVE

VM VOLT METER

W WATTS

W/ WITH

WH WATTHOUR METER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFMR SW TRANSFER SWITCH

XP EXPLOSION PROOF

1P SINGLE-PHASE

2P TWO-POLE

3P THREE-POLE

4P FOUR-POLE

∅ PHASE

GENERAL NOTESCONSULT ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL LIGHTING FIXTURES.

VERIFY ALL EQUIPMENT DIMENSIONS AND LOCATIONS BEFORE BEGINNING ROUGH IN. CONSULT ALL APPLICABLE CONTRACT DRAWINGS AND SHOP DRAWINGS TO INSURE NEC CODE CLEARANCES REQUIRED AROUND ALL ELECTRICAL EQUIPMENT.

CONTRACTOR SHALL VERIFY ALL ELECTRICAL LOADS (VOLTAGE, PHASE, CONNECTIONREQUIREMENTS, ETC) OF ALL EQUIPMENT FURNISHED UNDER ALL DIVISIONS, INCLUDING

ALL EXISTING EQUIPMENT TO BE RE-USED. REVIEW ALL SHOP DRAWINGS AND EXISTING EQUIPMENT BEFORE BEGINNING ROUGH-IN.

SEE SECTION 265100 (16510) OF THE SPECIFICATION FOR REQUIRED COORDINATION MEETINGS WITH MECHANICAL AND CEILING CONTRACTORS.

SEE APPLICABLE SHOP DRAWINGS FOR ROUGH IN LOCATION OF ALL EQUIPMENT, WIRING DEVICES, ETC. WHERE APPLICABLE MOUNT ALL WIRING DEVICES ABOVE BACK SPLASH EXCEPT THOSE SERVING UNDER COUNTER EQUIPMENT.

SEE SPECIFICATION FOR ENERGY SAVING LAMP AND BALLAST REQUIREMENTS.

FINISHES OF ALL LIGHT FIXTURES SHALL BE AS SELECTED BY ARCHITECT.

THE ELECTRICAL CONTRACTOR SHALL NOTIFY AND COOPERATE WITH THE MECHANICAL CONTRACTOR SUCH THAT NO PIPING, DUCTS, OR EQUIPMENT FOREIGN TO THE OPERATION OF THE ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE INSTALLED IN, ENTER OR PASS THRU ELECTRICAL ROOMS OR SPACES, OR ABOVE OR BELOW ELECTRICAL EQUIPMENT IN OTHER AREAS.

ELECTRICAL BOXES SHALL NOT BE LOCATED IN MASONRY COLUMNS IN BRICK WALLS OR IN GROUTED CELLS ADJACENT TO OPENINGS. COORDINATE LOCATION OF BOXES WITH MASONRY CONTRACTOR.

ALL PENETRATIONS OF FIRE RATED FLOORS, WALLS, AND CEILINGS SHALL BE SEALED WITH APPROVED MATERIAL TO MAINTAIN FIRE RATING OF SURFACE PENETRATED.

CIRCUITS EXTENDING OVER 70' FOR 120 VOLT AND 115' FOR 277 VOLT 20 AMP CIRCUITS SHALL BE RUN WITH CONDUCTORS PER TABLE BELOW.

10.

8.

7.

9.

5.

4.

6.

2.

1.

3.

11.

MAXIMUM LENGTH

20 AMP MINIMUM BRANCH CIRCUIT CONDUCTOR SIZING

BRANCH CIRCUIT VOLTAGE

CONDUCTOR LENGTH (FT) 120 VOLT 277 VOLT

<70 MIN. #12 AWG

70 - 115

115 - 170

170 - 270

271 - 380

>380

MIN. #12 AWG

MIN. #10 AWG MIN. #12 AWG

MIN. #8 AWG MIN. #10 AWG

MIN. #6 AWG MIN. #8 AWG

NOTE B MIN. #8 AWG

NOTE B NOTE B

A. THESE ARE BASED ON MAXIMUM LENGTH OF CIRCUIT.

B. PERFORM VOLTAGE DROP CALCULATIONS AND PROVIDE CONDUCTOR SIZE TO KEEPBRANCH CIRCUIT VOLTAGE DROP LESS THAN 3% WITH A 15 AMP LOAD.

C. CONTRACTOR SHALL ENSURE THAT THE INSTALLATION OF EACH BRANCH CIRCUITSTAYS WITHIN 3% VOLTAGE DROP FOR A 15 AMP LOAD. IF NECESSARY,CONTRACTOR SHALL INCREASE WIRE AND CONDUIT SIZE TO MEET THE STANDARD ATNO ADDITIONAL COST TO OWNER.

6.

CONTRACTOR SHALL VERIFY FURNITURE LAYOUT PRIOR TO ANY FLOORBOX OR POKE-THRU INSTALLATION. COORDINATE EXACT LOCATION OF FLOOR BOX OR POKE-THRU WITH OWNER AND FURNITURE PROVIDER PRIOR TO ROUGH-IN.

12.

DATA AND OTHER DEVICES, REFER TO DIAGRAMS

SEE SPEC. 27 1500

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

Page 26: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

S

H001H003

H004R001

TYPICAL TRAPEZE CONDUIT RACK

NTS

DIAGRAMTYPICAL RACEWAY SUPPORT METHODS

NTS

DIAGRAM

NTS

TYPICAL ROUGH IN REQUIREMENTSDIAGRAMDEVICE MOUNTING HEIGHTS

NTS

DIAGRAM

200A3P

200A3P

400A3PSPARE

400A3P

1200A3P

TOLAUNDRYBUILDING

TOBUILDING

4142

CULINARYDINNING

TO CULINARYBUILDING

200A3P

TO BUILDING414 AC PANEL

200A3PSPARE

TO WARDENBUILDING

3 SETS

2 WIRE

100A3P

TO BLDG 4141

(4) #1 CU WITH #6 CU GND IN 2" EMT CONDUIT

NO SCALE

ONE-LINE DIAGRAM

RACEWAY 3/4" TO 6"

(TYP.)

ALL THREAD ROD-SIZEAS REQUIRED

(MIN. 3/8")

SIZE AS REQUIRED

NUTS

FLAT WASHER

1/4" STEEL PLATE

NUT

FLAT WASHER

1/4" STEEL PLATE

ALL THREAD RODSIZE AS REQUIRED

STRUCTURAL UNIT

(BEAM, JOIST, SLAB, ETC.)DO NOT SUPPORTFROM BOTTOM CORDOF STEEL TRUSSES.

UNISTRUT CHANNEL -SIZE AS REQUIRED BYWEIGHT SUPPORTED

STRUCTURAL UNIT

CONDUIT HANGER

RACEWAY - 3/4" THRU 6"

ALL THREAD - SIZE AS

REQUIRED (3/8" MINIMUM)

NUTS

FLAT WASHER

1/4" STEEL PLATE

NUT

FLAT WASHER

1/4" STEEL PLATE

ALL THREAD RODSIZE AS REQUIRED

6"

4

OUTLET BOXTYPICAL

12"

48"

16"

12"

6

5

(TYP.)

6

TYP. FOR WOOD AND METAL STUD ROUGH-IN.

PLASTER RINGS NOT SHOWN. COORDINATE RINGDEPTH TO BE FLUSH WITH FINAL FINISHED SURFACE

LOCATE ALL OUTLET BOXES IN ACCORDANCE WITH ARCH. AND MECH. DRAWINGS,AND WITH ALL APPLICABLE SHOP DRAWINGS.

OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR PARTITIONS IN THE SAME STUD

SPACE MUST BE SEPARATED BY A MIN. OF 6" HORIZONTAL DISTANCE.

ELECTRICAL BOXES INSTALLED IN FIRE RESISTANT WALLS OR PARTITIONS SHALL

COMPLY WITH IBC 714.3.2 (24" SEPARATION ON OPPOSITE SIDES OR WITH FIRESTOP PUTTY ON EACH BOX.)

INSULATED THROAT EMT CONNECTOR.

CADDY FASTENER, THROUGH STUD CABLE/CONDUIT SUPPORT 'FB12P'.

CADDY BOX MOUNTING BRACKET 'RBS16'.

4

3

2

1

NOTES:

(TYP.)

5

EMT

EMT

EMT

EMT

7

7

EMT

CL

LCADJUSTABLEBAR HANGER

(TYP.)

8

8

FLOOR LINE

16

" M

IN.

48

" M

AX

IMU

M

TYPICAL REFLECTED CEILING

HORN/STROBE

INSTALL SPEAKERS ANDSMOKE DETECTORS INSAME LAY-IN TILE

WHERE DEVICES ARE SHOWN INSAME WALL SPACE, ALIGNVERTICALLY AND HORIZONTALLYAS SHOWN. COORDINATE WITHARCHITECTURAL DRAWINGS &CABINETRY DRAWINGS

96"

TYPICAL WALL SECTION

J

VOLUMECONTROL

WALLPHONE

LIGHTSWITCH

OUTLET DATAOUTLET

FIRE ALARMPULL STATION

JUNCTION BOX

OUTLET

IC

OAKESON

JOSHUA

No. 7707671-2202

GIN

EER

ONA

OF

ESSI

R

UTAH

TE OF

STA

P

L EN

2018 BNA CONSULTING SA

LT L

AK

E

ST.G

EO

RG

ESuite 202St. George, Utah 84770

CONSULTING

P:435.628.3670F:435.628.3680

www.bnaconsulting.com

393 East Riverside Drive

BNA

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

2/1

3/2

020

10:1

3:3

8 P

M

E0.02

SCHEDULES

29 JANUARY 2019

22564.000

For Information Only

LIGHT FIXTURE GENERAL NOTES

LIGHT FIXTURE ABBREVIATION SCHEDULE

1. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF LIGHT FIXTURES. BRING ALL DISCREPANCIES OF LOCATIONS AND QUANTITIES TO THE ATTENTION OF THE ARCHITECT AND ELECTRICAL ENGINEER PRIOR TO BIDDING.

2. REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS AND LOCATIONS OF LIGHT FIXTURES. BRING ALL DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING.

3. REFER TO THE SPECIFICATIONS FOR OTHER LIGHT FIXTURE, FUSING, BALLAST, AND LAMP REQUIREMENTS AND ACCEPTABLE MANUFACTURERS.

4. CONFIRM AVAILABLE MOUNTING DEPTHS OF ALL LIGHT FIXTURES AND COMPARE WITH DEPTHS SHOWN ON SHOP DRAWINGS. BRING ALL POTENTIAL CONFLICT AREAS TO THE ATTENTION OF THE ARCHITECT AND ELECTRICAL ENGINEER PRIOR TO RELEASE.

5. REFER TO LIGHTING PLANS FOR ALL LINEAR FIXTURE LENGTHS. THE CATALOG NUMBER IS BASED ON THE FIXTURE SPECIFIED AND MAY NOT REFLECT THE QUANTITY OR OVERALL LENGTH OF LINEAR FIXTURES REQUIRED. CONTRACTOR TO NOTE THAT VARIOUS FIXTURE LENGTHS MAY BE REQUIRED TO ACHIEVE THE OVERALL RUN LENGTH.

6. REFER TO LIGHTING PLANS FOR ALL UNDERCABINET FIXTURE LENGTHS. THE CATALOG NUMBER IS BASED ON THE FIXTURE SPECIFIED AND MAY NOT REFLECT THE QUANTITY OR OVERALL LENGTH OF THE UNDERCABINET FIXTURES REQUIRED. CONTRACTOR TO NOTE THAT VARIOUS FIXTURE LENGTHS MAY BE REQUIRED TO ACHIEVE THE OVERALL RUN LENGTH OR TO FIT THE WITHIN THE MILLWORK. COORDINATE FIXTURE LAYOUT WITH MILLWORK SHOPDRAWINGS PRIOR TO LIGHTING SUBMITTALS.

7. WHEN A CONTRADICTION EXISTS BETWEEN A SPECIFIC MODEL NUMBER AND THE DESCRIPTION, NOTIFY THE ELECTRICAL ENGINEER AND/OR LIGHTING DESIGNER.

8. PRIOR APPROVALS ARE REQUIRED BEFORE BIDDING THE PROJECT AND SHALL BE SUBMITTED TO THE ELECTRICAL ENGINEER'S OFFICE AT LEAST (8) EIGHT WORKING DAYS BEFORE THE BID. PRIOR APPROVALS RECEIVED AFTER THIS TIME PERIOD SHALL BE REJECTED.

9. REFER TO SPECIFICATIONS 260500, 265100 & 265600 (16001, 16510 & 16551).

10. VALUE ENGINEERING CONDUCTED WITHOUT THE DESIGN TEAM IE; ARCHITECT, OWNER, ENGINEER & LIGHTING CONSULTANT/DESIGNER WILL NOT BEALLOWED, REVIEWED OR APPROVED.

SFBA

CFBAWALL@CLG

CCBA

SCBAA.F.F.

STANDARD FINISH AS SELECTED BY THE ARCHITECT

CUSTOM FINISH AS SELECTED BY THE ARCHITECT

STANDARD PAINTED COLOR AS SELECTED BY THE ARCHITECT

CUSTOM PAINTED COLOR AS SELECTED BY THE ARCHITECT

WALL MOUNT AT CORNER OF WALL AND CEILING

ABOVE FINISH FLOOR

SENSOR GENERAL NOTESTHE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE SENSOR MANUFACTURER FOR PROPER PLACEMENT AND ADJUSTMENT OF OCCUPANCY SENSORS.

EACH ZONE SHALL HAVE COVERAGE BY OCCUPANCY SENSOR SUCH THAT NO BLIND SPOT EXIST.

UPON COMPLETION OF THE INSTALLATION, THE SYSTEM SHALL BE COMPLETELY COMMISSIONED BY THE MANUFACTURER'S FACTORY AUTHORIZED TECHNICIAN WHO WILL VERIFY ALL ADJUSTMENTS AND SENSOR PLACEMENT TO ENSURE A TROUBLE FREE INSTALLATION.

THE LOCATION AND QUANTITIES OF SENSORS SHOWN ON THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE ROOMS WHICH ARE TO BE PROVIDED WITH SENSORS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ADDITIONAL SENSORS IF REQUIRED TO PROPERLY COVER THE RESPECTIVE ROOM.

NOTES:NOTES:NOTES:NOTES:

1. NON1. NON1. NON1. NON----FUSED DISCONNECT SWITCHFUSED DISCONNECT SWITCHFUSED DISCONNECT SWITCHFUSED DISCONNECT SWITCH A. FURNISHED, INSTALLED, AND CONNECTED UNDER DIVISION 26(16).A. FURNISHED, INSTALLED, AND CONNECTED UNDER DIVISION 26(16).A. FURNISHED, INSTALLED, AND CONNECTED UNDER DIVISION 26(16).A. FURNISHED, INSTALLED, AND CONNECTED UNDER DIVISION 26(16).

2. FUSED DISCONNECT SWITCH2. FUSED DISCONNECT SWITCH2. FUSED DISCONNECT SWITCH2. FUSED DISCONNECT SWITCH B. FURNISHED AND INSTALLED UNDER ANOTHER DIVISION REQUIRINGB. FURNISHED AND INSTALLED UNDER ANOTHER DIVISION REQUIRINGB. FURNISHED AND INSTALLED UNDER ANOTHER DIVISION REQUIRINGB. FURNISHED AND INSTALLED UNDER ANOTHER DIVISION REQUIRING

3. BREAKER IN ENCLOSURE3. BREAKER IN ENCLOSURE3. BREAKER IN ENCLOSURE3. BREAKER IN ENCLOSURE CONNECTION UNDER DIVISION 26(16).CONNECTION UNDER DIVISION 26(16).CONNECTION UNDER DIVISION 26(16).CONNECTION UNDER DIVISION 26(16).

4. MANUAL STARTER W/THERMAL OVERLOAD4. MANUAL STARTER W/THERMAL OVERLOAD4. MANUAL STARTER W/THERMAL OVERLOAD4. MANUAL STARTER W/THERMAL OVERLOAD C. FURNISHED UNDER ANOTHER DIVISION BUT INSTALLED ANDC. FURNISHED UNDER ANOTHER DIVISION BUT INSTALLED ANDC. FURNISHED UNDER ANOTHER DIVISION BUT INSTALLED ANDC. FURNISHED UNDER ANOTHER DIVISION BUT INSTALLED AND

5. MAGNETIC STARTER5. MAGNETIC STARTER5. MAGNETIC STARTER5. MAGNETIC STARTER CONNECTED UNDER DIVISION 26(16).CONNECTED UNDER DIVISION 26(16).CONNECTED UNDER DIVISION 26(16).CONNECTED UNDER DIVISION 26(16).

6. MAGNETIC STARTER/NON6. MAGNETIC STARTER/NON6. MAGNETIC STARTER/NON6. MAGNETIC STARTER/NON----FUSED DISCONNECT COMBINATIONFUSED DISCONNECT COMBINATIONFUSED DISCONNECT COMBINATIONFUSED DISCONNECT COMBINATION D. FURNISHED, INSTALLED AND CONNECTED UNDER ANOTHER DIVISION.D. FURNISHED, INSTALLED AND CONNECTED UNDER ANOTHER DIVISION.D. FURNISHED, INSTALLED AND CONNECTED UNDER ANOTHER DIVISION.D. FURNISHED, INSTALLED AND CONNECTED UNDER ANOTHER DIVISION.

7. MAGNETIC STARTER/FUSED DISCONNECT COMBINATION7. MAGNETIC STARTER/FUSED DISCONNECT COMBINATION7. MAGNETIC STARTER/FUSED DISCONNECT COMBINATION7. MAGNETIC STARTER/FUSED DISCONNECT COMBINATION

8. MAGNETIC STARTER/BREAKER COMBINATION8. MAGNETIC STARTER/BREAKER COMBINATION8. MAGNETIC STARTER/BREAKER COMBINATION8. MAGNETIC STARTER/BREAKER COMBINATION CB = CIRCUIT BREAKER CB = CIRCUIT BREAKER CB = CIRCUIT BREAKER CB = CIRCUIT BREAKER ---- THERMAL MAGNETICTHERMAL MAGNETICTHERMAL MAGNETICTHERMAL MAGNETIC9. VARIABLE FREQUENCY DRIVE9. VARIABLE FREQUENCY DRIVE9. VARIABLE FREQUENCY DRIVE9. VARIABLE FREQUENCY DRIVE CKW = CHILLER KILOWATTSCKW = CHILLER KILOWATTSCKW = CHILLER KILOWATTSCKW = CHILLER KILOWATTS

10. REDUCED VOLTAGE STARTER10. REDUCED VOLTAGE STARTER10. REDUCED VOLTAGE STARTER10. REDUCED VOLTAGE STARTER

11. DIRECT CONNECTION11. DIRECT CONNECTION11. DIRECT CONNECTION11. DIRECT CONNECTION

12. RECEPTACLE/SPECIAL PURPOSE OUTLET/ETC.12. RECEPTACLE/SPECIAL PURPOSE OUTLET/ETC.12. RECEPTACLE/SPECIAL PURPOSE OUTLET/ETC.12. RECEPTACLE/SPECIAL PURPOSE OUTLET/ETC. NOTE 1: PER 250.122(A), EQUIPMENT GROUND IS NOT REQUIRED TO BENOTE 1: PER 250.122(A), EQUIPMENT GROUND IS NOT REQUIRED TO BENOTE 1: PER 250.122(A), EQUIPMENT GROUND IS NOT REQUIRED TO BENOTE 1: PER 250.122(A), EQUIPMENT GROUND IS NOT REQUIRED TO BE13. TWO13. TWO13. TWO13. TWO----SPEED STARTER, COORDINATE W/MOTOR TYPESPEED STARTER, COORDINATE W/MOTOR TYPESPEED STARTER, COORDINATE W/MOTOR TYPESPEED STARTER, COORDINATE W/MOTOR TYPE LARGER THAN PHASE CONDUCTOR.LARGER THAN PHASE CONDUCTOR.LARGER THAN PHASE CONDUCTOR.LARGER THAN PHASE CONDUCTOR.

14. SOLID STATE SOFT STARTER14. SOLID STATE SOFT STARTER14. SOLID STATE SOFT STARTER14. SOLID STATE SOFT STARTER

EQUIPMENT SCHEDULE

UNITUNITUNITUNIT #### DESCRIPTIONDESCRIPTIONDESCRIPTIONDESCRIPTION

LOADLOADLOADLOAD

VOLVOLVOLVOLTTTT

PH

AS

EP

HA

SE

PH

AS

EP

HA

SE

FU

LL

LO

AD

AM

PS

FU

LL

LO

AD

AM

PS

FU

LL

LO

AD

AM

PS

FU

LL

LO

AD

AM

PS

CO

ND

UIT

S

IZE

CO

ND

UIT

S

IZE

CO

ND

UIT

S

IZE

CO

ND

UIT

S

IZE

WIRESWIRESWIRESWIRES OCPDOCPDOCPDOCPDREFERENCEREFERENCEREFERENCEREFERENCE

NOTESNOTESNOTESNOTES

HP

HP

HP

HP

FL

AF

LA

FL

AF

LA

MC

AM

CA

MC

AM

CA

VA

VA

VA

VA

SE

TS

SE

TS

SE

TS

SE

TS

QT

YQ

TY

QT

YQ

TY

SIZ

ES

IZE

SIZ

ES

IZE

EQ

UIP

. G

ND

.E

QU

IP.

GN

D.

EQ

UIP

. G

ND

.E

QU

IP.

GN

D.

TY

PE

TY

PE

TY

PE

TY

PE

AM

PS

AM

PS

AM

PS

AM

PS

ST

AR

TE

RS

TA

RT

ER

ST

AR

TE

RS

TA

RT

ER

DIS

CO

NN

EC

TD

ISC

ON

NE

CT

DIS

CO

NN

EC

TD

ISC

ON

NE

CT

OT

HE

RO

TH

ER

OT

HE

RO

TH

ER

REMARREMARREMARREMARKSKSKSKS

EF 1 EXHAUST FAN 1.00 208 V 3 4.6 A 3/4" 1 3 12 12 CB 15 A 7A

MAU 1 MAKE-UP AIR UNIT 1.50 208 V 3 6.6 A 3/4" 1 3 12 12 CB 20 A 2A

RCP 1 RE-CIRC PUMP 2 A 0 A 0 VA 120 V 1 2.3 A 3/4" 1 2 12 12 CB 15 A 4A

UH 1 UNIT HEATER 7 A 0 A 0 VA 208 V 1 6.9 A 3/4" 1 2 12 12 CB 20 A 4A

FIXTURE SCHEDULEFIXTURE SCHEDULEFIXTURE SCHEDULEFIXTURE SCHEDULE

Project Manager: JOSH OAKESON

TYPETYPETYPETYPE DESCRIPTIONDESCRIPTIONDESCRIPTIONDESCRIPTION MFR.MFR.MFR.MFR. CATALOG NUMBERCATALOG NUMBERCATALOG NUMBERCATALOG NUMBER VOLTSVOLTSVOLTSVOLTSTOTALTOTALTOTALTOTALWATTSWATTSWATTSWATTS LAMPLAMPLAMPLAMP

A1 1X4 SURFACE MOUNTED FLAT PANEL LED FIXTURE DAY-BRITE 1-FXP-38L-840-4-DS-120-DIM-FSK-14 120 V 46 LED

A2 1X2 SURFACE MOUNTED FLAT PANEL LED FIXTURE DAY-BRITE 1-FXP-38L-840-2-DS-120-DIM-FSK-14 120 V 30 LED

D1 4" DOWN LIGHT OPAL LENS WHITE TRIM, WHITE LOCATION LIGHTOLIER CP4RB07830W 120 V 11 LED

E1 EMERGENCY BATTERY PACK LIGHT FIXTURE, 90 MINUTEBATTERY

CHLORIDE VLLU 120 V 3 LED

WP TRAPEZOID WALL PACK COMPACT LED WITH BATTERY PACK LITHONIA WST-LED-P2-40K-VF-MVOLT-E7WC 120 V 30 LED

1.

2.

3.

4.

400A CULINARY

200A WARDEN BUILDING

200A BUILDING 414

200A BUILDING 4142

200A LAUNDRY BUILDING

400A CULINARYDINNING BUILDING

1. EXISTING SWITCHBOARD IS PICTURED TO THE LEFT. SCOPE IS TO REPLACE EXISTING SWITCHBOARD WITH NEW NEMA 3R SWITCHBOARD. PROVIDE CIRCUIT BREAKERS AS NOTED BELOW. LOCATE CIRCUIT BREAKERS AS TO ALLOW FOR REUSE OF EXISTING CABLE.

2. RECONNECT PANEL TO EXISTING EARTH GROUND SYSTEM.

SWITCHBOARD NOTES

MAIN CIRCUITBREAKER

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

Page 27: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

PP

PP

PP

PP

PP

PP'L1'

A2

D1

D1

D1

D1

D1

D1 D1

D1

D1

D1

D1

A1

A1

A1A1

A1

A1A1

A1

A1 A1

A1

A1A1 A1

A1A1

L1- 1

L1- 1

L1- 1

L1- 1

L1- 1

L1- 1

L1- 1

L1- 1

L1- 1

L1- 1

L1- 1

L1- 1L1- 1

L1- 1

L1- 1L1- 1

L1- 1

L1- 1 L1- 1 L1- 1

L1- 1L1- 1

L1- 1

L1- 1L1- 1

L1- 1 L1- 1

L1- 1

L1- 1E1

E1

E1L1- 1

L1- 1

A2A1

L1- 1E1

a

b

ab

a

a

a

a

a

b

bb

b

a

a

a

a

a

c

c

c c

c

c

c

c

c

d

d

d

d d

dd

dd

dd

WP

WP

WP

L1- 1L1- 1

E1

L1- 1

E1L1- 1

WPL1- 23

L1- 23

L1- 23

L1- 23

OAKESON

JOSHUA

No. 7707671-2202

GIN

EER

ONA

OF

ESSI

R

UTAH

TE OF

STA

P

L EN

2018 BNA CONSULTING SA

LT L

AK

E

ST.G

EO

RG

ESuite 202St. George, Utah 84770

CONSULTING

P:435.628.3670F:435.628.3680

www.bnaconsulting.com

393 East Riverside Drive

BNA

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

2/1

3/2

020

10:1

3:4

0 P

M

E2.01

LIGHTING PLAN

29 JANUARY 2019

22564.000

For Information Only

SCALE = 1/4" = 1'-0"

LIGHTING PLAN1

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS

Page 28: CONSTRUCTION DOCUMENTSmscibuild.com/wp-content/uploads/2020/02/20200214_Camp... · 2020-02-14 · 11 toilet stalls 09 urinal stalls 12 lavatories 04 utility sinks 11 showers v e r

F

T

T

'L1'

L1-16

L1-18

L1-4 L1-12

L1-2 L1-10

L1-6 L1-14

L1-8

L1-16

L1-18

L1-18L1-13,15,17

MAU

1

EF

1

UH

1

L1-7,9,11

L1-3,5

WP

WP

L1-16

E2

E2

E2

E2

E2

E2

E2

E3

WP

WPL1-18

L1-16

L1-21 L1-16

L1-19RCP

1

WATER HEATERS

E5

E4

OAKESON

JOSHUA

No. 7707671-2202

GIN

EER

ONA

OF

ESSI

R

UTAH

TE OF

STA

P

L EN

2018 BNA CONSULTING SA

LT L

AK

E

ST.G

EO

RG

ESuite 202St. George, Utah 84770

CONSULTING

P:435.628.3670F:435.628.3680

www.bnaconsulting.com

393 East Riverside Drive

BNA

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

REVISION

PROJECT NUMBERS

DATE

SHEET TITLE

PLO

T

DA

TE

:

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

ISSUE

© 2005 HKS, INC.

CA

MP

WIL

LIA

MS

BU

ILD

ING

41

41

RE

NO

VA

TIO

NS

SHEET NO.

HKS:

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

OWNER

STATE OF UTAHDIVISION OF FACILITIES CONSTRUCTION AND MANAGEMENT 4110 STATE OFFICE BUILDINGSALT LAKE CITY, UTAH 84114

UTAH NATIONAL GUARDCAMP WILLIAMS17800 S 1700 W BLUFFDALE, UT 84065

2/1

3/2

020

10:1

3:4

1 P

M

E3.01

POWER AND SYSTEMS

PLAN

29 JANUARY 2019

22564.000

For Information Only

SHEET KEYNOTESE2 COORDINATE MOUNTING HIEGHT AND LOCATION ARCHITECTURAL ELEVATIONS AND

ARCHITECT/OWNER. PRIOR TO ROUGH-IN.

E3 PROVIDE ELECTRICAL METER AT PANEL FEEDER. PROVIDE VERIS INDUSTRIES H8400.CONNECT METER TO SCHNEIDER ELECTRIC STURXUREWARE (PROVIDED BY OTHERS).

E4 PROVIDE (1) 4' CONDUIT TO TELEPHONE/DATA MANHOLE IN STREET. COORDINATE LOCATIONWITH CAMP WILLIAMS FACILITY PERSONNEL.

E5 EXISTING DISTRIBUTION PANEL. UPGRADE PANEL AS SHOWN ON SHEET E0.02. PROVIDE NEWFEEDER TO PANEL L1.

SCALE = 1/4" = 1'-0"

POWER AND SYSTEMS PLAN1

AIC RATING 22,000 AMPS RMS SYSM.

* PROVIDE 5mA GFCI CIRCUIT BREAKER

Legend: 31 A 35 A 30 A AMPS/PHASEAMPS/PHASEAMPS/PHASEAMPS/PHASE 11508 VA

3703 4183 3623 TOTAL (VA)TOTAL (VA)TOTAL (VA)TOTAL (VA) CONNECTED LOAD TOTAL

41 42

39 40

37 38

35 36

33 34

31 32

SPARE 20 A 1 -- 29 0 VA 0 VA 30 -- 1 20 A SPARE

SPARE 20 A 1 -- 27 0 VA 0 VA 28 -- 1 20 A SPARE

SPARE 20 A 1 -- 25 0 VA 0 VA 26 -- 1 20 A SPARE

EXTERIOR LIGHTING 20 A 1 12 23 120 VA 0 VA 24 -- 1 20 A SPARE

WH-1 WATER HEATERS 20 A 1 12 21 500 VA 0 VA 22 -- 1 20 A SPARE

RCP-1 RE-CIRC PUMP 15 A 1 12 19 276 VA 0 VA 20 -- 1 20 A SPARE

-- -- -- -- 17 793 VA 720 VA 18 12 1 20 A RECEPTACLES

-- -- -- -- 15 793 VA 900 VA 16 12 1 20 A RECEPTACLES

MAU-1 MAKE-UP AIR UNIT 20 A 3 12 13 793 VA 360 VA 14 12 1 20 A RECEPTACLE

-- -- -- -- 11 552 VA 360 VA 12 12 1 20 A RECEPTACLE

-- -- -- -- 9 552 VA 360 VA 10 12 1 20 A RECEPTACLE

EF-1 EXHAUST FAN 15 A 3 12 7 552 VA 360 VA 8 12 1 20 A RECEPTACLE

-- -- -- -- 5 718 VA 360 VA 6 12 1 20 A RECEPTACLE

UH-1 UNIT HEATER 20 A 2 12 3 718 VA 360 VA 4 12 1 20 A RECEPTACLE

LIGHTING 20 A 1 12 1 1002 VA 360 VA 2 12 1 20 A RECEPTACLE

ITEMITEMITEMITEM AMPSAMPSAMPSAMPS POLEPOLEPOLEPOLEWIREWIREWIREWIRESIZESIZESIZESIZE

CIR.CIR.CIR.CIR.NO.NO.NO.NO. AAAA BBBB CCCC AAAA BBBB CCCC

CIR.CIR.CIR.CIR.NO.NO.NO.NO.

WIREWIREWIREWIRESIZESIZESIZESIZE POLEPOLEPOLEPOLE AMPSAMPSAMPSAMPS ITEMITEMITEMITEM

BRANCH BREAKERSBRANCH BREAKERSBRANCH BREAKERSBRANCH BREAKERS

SPD

200% NEUTRAL

ISO GROUND

AMP:AMP:AMP:AMP: 100 A DOOR-IN-DOOR

BUSSING:BUSSING:BUSSING:BUSSING: FED FROM:FED FROM:FED FROM:FED FROM: SUBFEED LUGS

MOUNTING:MOUNTING:MOUNTING:MOUNTING: SURFACE LOCATION:LOCATION:LOCATION:LOCATION: MECH 106 MAINS:MAINS:MAINS:MAINS: MLO

PANEL:PANEL:PANEL:PANEL: L1L1L1L1 TYPE:TYPE:TYPE:TYPE: Type 1 VOLTS:VOLTS:VOLTS:VOLTS: 120/208 Wye PHASE:PHASE:PHASE:PHASE: 3 WIRES:WIRES:WIRES:WIRES: 4

PANELBOARD SCHEDULEPANELBOARD SCHEDULEPANELBOARD SCHEDULEPANELBOARD SCHEDULE

NO. DESCRIPTION DATE

HKS ARCHITECTS, INC.

SALT LAKE CITY, UTAH 84101

ARCHITECT

90 SOUTH 400 WEST, SUITE 110

ARW ENGINEERS

OGDEN, UTAH 84404

STRUCTURAL ENGINEER

1594 PARK CIRCLE

CA

MP

WIL

LIA

MS

BNA CONSULTING

SALT LAKE CITY, UTAH 84111

ELECTRICAL ENGINEER

635 SOUTH STATE STREET

UT

AH

NA

TIO

NA

L G

UA

RD

ST

AT

E O

F U

TA

H D

IVIS

ION

OF F

AC

ILIT

IES

CO

NS

TR

UC

TIO

N A

ND

MA

NA

GE

ME

NT

VAN BOERUM & FRANK

SALT LAKE CITY, UTAH 84111

MECHANICAL ENGINEER

330 SOUTH 300 WEST

BU

IL

DIN

G 4

14

1 R

EN

OV

AT

IO

NS


Recommended