+ All Categories
Home > Documents > Construction drawings

Construction drawings

Date post: 22-Mar-2016
Category:
Upload: nicholas-cheung
View: 217 times
Download: 2 times
Share this document with a friend
Description:
Architectural Technologies 2 Drawn with Archicad.
Popular Tags:
6
BDES 2013 ARCHITECTURAL TECHNOLOGIES 2 FACULTY OF ARCHITECTURE DESIGN & PLANNING DOMAIN PARK PUBLIC TOILET PROPOSAL DRAWING NAME DRAWING NAME ALL EXISTING DOWNPIPES TO BE REUSED FOR NEW ROOF ALL EXISTING INTERNAL WALLS TO BE DEMOLISHED ALL EXISTING INTERNAL WC CUBICLES TO BE REMOVED ALL EXISTING SANITARY FIXTURES TO BE REMOVED PREPARE CONNECTIONS FOR NEW FIXTURES ALL EXISTING SANITARY FIXTURES TO BE REMOVED EXISTING TIMBER POSTS TO BE DEMOLISHED EXISTING URINAL TROUGH TO BE REMOVED. PREPARE CONNECTIONS FOR NEW URINALS EXISTING FLOOR TILES TO BE REMOVED. PREPARE FLOOR FOR NEW TILE COVERING INNER LAYER OF EXISTING DOUBLE BRICK ALL TO BE RETAINED STORAGE SPACE MALE WC FEMALE WC WC WC WC WC WC WC URINAL TROUGH TILES TILES DP DP SK SK SK SK SK SK SK SK LEGEND INDICATES EXTENT OF EXISTING WALL TO BE RETAINED INDICATES EXTENT OF DEMOLITION NOTE: EXISTING ROOF CLADDING & ROOF STRUCTURE TO BE DEMOLISHED. PREPARE FOR NEW ROOF MAKE GOOD EXISTING MATERIALS. 0.0 0.5 1.0 2.0 3.0 3.0 DEMOLITION PLAN 1:50 @ A2 A1.1
Transcript
Page 1: Construction drawings

BDES 2013 ARCHITECTURAL TECHNOLOGIES 2FACULTY OF ARCHITECTURE DESIGN & PLANNING

DOMAIN PARK PUBLIC TOILET PROPOSAL DRAWING NAME DRAWING NAME

ALL EXISTING DOWNPIPES TO BE REUSEDFOR NEW ROOF

ALL EXISTING INTERNAL WALLS TO BEDEMOLISHED

ALL EXISTING INTERNAL WC CUBICLESTO BE REMOVED

ALL EXISTING SANITARY FIXTURESTO BE REMOVED PREPARECONNECTIONS FOR NEW FIXTURES

ALL EXISTING SANITARY FIXTURES TOBE REMOVED

EXISTING TIMBER POSTS TO BEDEMOLISHED

EXISTING URINAL TROUGH TO BEREMOVED. PREPARE CONNECTIONSFOR NEW URINALS

EXISTING FLOOR TILES TO BEREMOVED. PREPARE FLOOR FORNEW TILE COVERING

INNER LAYER OF EXISTING DOUBLEBRICK ALL TO BE RETAINED

STORAGESPACEMALE WC FEMALE WC

WC WC WC WC WC WC

UR

INAL

TR

OU

GH

TILES TILES

DP

DP

SK SK SK SK SK SK SK SK

LEGEND

INDICATES EXTENT OF EXISTINGWALL TO BE RETAINED

INDICATES EXTENT OF DEMOLITION

NOTE: EXISTING ROOF CLADDING & ROOFSTRUCTURE TO BE DEMOLISHED. PREPAREFOR NEW ROOF MAKE GOOD EXISTINGMATERIALS.

0.0 0.5 1.0 2.0 3.0 3.0

DEMOLITION PLAN 1:50 @ A2 A1.

1

Page 2: Construction drawings

BDES 2013 ARCHITECTURAL TECHNOLOGIES 2FACULTY OF ARCHITECTURE DESIGN & PLANNING

DOMAIN PARK PUBLIC TOILET PROPOSAL DRAWING NAME DRAWING NAME

250 10,500 250

250 4,000 110 1,990 110 4,290 250

1,670 2,330

6,80

0

250 1,400 110 2,490 110 1,990 110 2,490 110 1,690 250

250

1,84

011

02,

750

250

810

400 150 2,363 150 2,363 150 2,363 150 2,363 150 400

2,640 1,650

810

11,000

100

150

1,35

025

04,

700

250

1,60

05,

200

250

1,69

011

02,

900

250

STORAGESPACEMALE WC FEMALE WC

WC WC WC WC WC WC

SK

UR

INAL

TR

OU

GH

DP

DP

TILES TILES

SK SK SK SK SK SK SK

LEGEND

EXTENT OF EXISTING DOUBLEBRICK WALL CONSTRUCTION

EXTENT OF EXISTING SINGLEBRICK WALL CONSTRUCTION

EXTENT OF EXISTING 2OOX100CERAMIC TILES

WC

LOCATIONS OF EXISTING 150X150TIMBER POSTS

LOCATIONS OF EXISTING WATERCLOSETS

SK LOCATIONS OF EXISTING SINKS

DP INDICATES LOCATIONS OF EXISTINGDOWNPIPE

NOTE: EXISTING STORAGE SPACE COULD NOTBE INVESTIGATED AS THE SPACE WAS LOCKED

0.0 0.5 1.0 2.0 3.0 3.0

EXISTING FLOOR PLAN 1:50 @ A2 A1.

0

Page 3: Construction drawings

BDES 2013 ARCHITECTURAL TECHNOLOGIES 2FACULTY OF ARCHITECTURE DESIGN & PLANNING

DOMAIN PARK PUBLIC TOILET PROPOSAL DRAWING NAME DRAWING NAME

2,40

01,

200

400

1,52

0

5,52

0

EXISTING DOUBLE BRICK WALLCONSTRUCTION

EXISTING FLOOR TILES

EXISTING CONCRETE SLABFOUNDATION WITHDAMPROOF MEMBRANE

ROOF TILES ON EXISTING TIMBERROOF TRUSS CONSTRUCTION

EXISTING URINAL TROUGHSHOWN IN FOREGROUND

EXISTING TIMBER POSTS

EXISTING DOUBLE BRICK WALLCONSTRUCTION

EXISTING WALL TILES MATCHINGFLOOR TILE PROFILE

OPAQUE SINGLE GALZED GLASSWINDOW WITH TIMBER FRAMINGWINDOW NOT OPENABLE

EXISTING TIMBER BEAM SPANNINGOVER PORCH OPENING

ROOF TILES ON EXISTING TIMBERROOF FRAMING CONSTRUCTION

EXISTING ROOF GUTTER

BRICK WALL SHOWN IN ELEVATION

NATURAL GROUND LEVEL

RL 0.00

RL 5.520

RL 2.400

RL 3.600

HIGHEST POINT

EXISTING GROUND LEVEL

RL 4.000

30° PITCH

15° ROOF PITCH

0.0 0.5 1.0 2.0 3.0 3.0

EXISTING SECTION 1:20 @ A2 A3.

0

Page 4: Construction drawings

BDES 2013 ARCHITECTURAL TECHNOLOGIES 2FACULTY OF ARCHITECTURE DESIGN & PLANNING

DOMAIN PARK PUBLIC TOILET PROPOSAL DRAWING NAME DRAWING NAME

110 3,860 150 150 2,330 150 3,860 110

10,720

100

1,00

010

02,

390

100

1,01

011

0

100

5,16

011

0

4,5752,730

4,000

4,81

0

5,37

0

1006,500

100

25E

Q25

EQ

25E

Q

3,60

0

25 1,900 1,900 25

610

100

STORAGESPACE

MALE WC FEMALE WCTILES TILES

DISABLEDWC

EXTENT OF NEW ROOF SHOWN DASHED

TILES

SK

WC

WC

WC

WCUN

UN

UN

01A3.1

STO

RA

GE

DIS

AB

LED

WC

MALE WC DISABLED WC FEMALE WC

TPH

TPH

TPH

TPH

TPH

TPH

TPHDP

WC

WC

WC

SONNY

01A3.2NICK

01A3.1 SONNY

01A3.2 NICK

01A3.3 LENA

01A3.3 LENA

01A3.4 MICHELLE

01A3.4 MICHELLE

FALL

TO

WA

RD

SD

RA

INA

GE

CH

AN

NE

L

FALL

TO

WA

RD

SD

RA

INA

GE

CH

AN

NE

L

STEEL BEAM SHOWN DASHED OVER

SK / DF

LEGEND

EXTENT OF EXISTING WALLCONSTRUCTION

EXTENT OF PROPOSED WALLCONSTRUCTION REFER TO SECTIONSFOR FURTHER INFORMATION

EXTENT OF NEW 200X200 CERAMICFLOOR TILES

WC

LOCATIONS OF NEW STRUCTURALSTEEL POSTS (TO STRUCT. REQ.)

LOCATIONS OF NEW WATERCLOSETS

DP INDICATES LOCATIONS OF REUSEDDOWNPIPE

UN LOCATIONS OF NEW URINALS

TPH LOCATIONS OF NEW TOILET PAPERHOLDERS

SK / DF LOCATIONS OF NEW SINK ANDDRINKING FOUNTAIN TROUGHS/S FINISH WITH STEEL FRAMEDJOINERY CLAD IN SANDSTONE

0.0 0.5 1.0 2.0 3.0 3.0

PROPOSED FLOOR PLAN 1:50 @ A2 A1.

2

Page 5: Construction drawings

BDES 2013 ARCHITECTURAL TECHNOLOGIES 2FACULTY OF ARCHITECTURE DESIGN & PLANNING

DOMAIN PARK PUBLIC TOILET PROPOSAL DRAWING NAME DRAWING NAME

0.0 0.5 1.0 2.0 3.0 3.0

COLORBOND CORRUGATED STEELROOFING WITH WHITE

ALUMINIUM LOUVERSATTACHED TOEXISTING BRICKVERNEER

INTERNAL GUTTER WITHTO DOWNPIPE. GUTTER ON 100 X 50TREATED TIMBER FRAMING

75 X 50 TREATED TIMBERPURLINS @ 600MM CRS. MAX.ON 150 X 50 TREATED TIMBERRAFTERS @ 600MM CRS. MAX.

200 X 200 CERAMIC FLOORTILES WITH NON SLIP FINISHWITH 20MM SCREEDING

EXISTING BRICK VERNEER WALL

NEW 25MM THICK H'WOODWC CUBICLES.CONNECT TO EXISTINGDRAINAGE

NEW CONCRETE FLOOR SLABWITH STEEL REINFORCINGMESH

SECTION 1:25 @ A2 A3.

2

4,40

0

500

2,50

0

Page 6: Construction drawings

BDES 2013 ARCHITECTURAL TECHNOLOGIES 2FACULTY OF ARCHITECTURE DESIGN & PLANNING

DOMAIN PARK PUBLIC TOILET PROPOSAL DRAWING NAME DRAWING NAME

3,00

033

01,

070

4,40

0

1,50

0

2,00

0

250

4050

02,

500

500

900

STRUCTURAL STEEL SHS POSTTO ENGINEERS REQUIREMENTS

EXISTING BRICK VENEER WALL

NEW 25MM THICK JARRAH HARDWOODWC CUBICLES WITH NEW SANITARYFIXTURES. CONNECT TO EXISTINGDRAINAGENEW 200 X 200 CERAMIC FLOOR

TILES WITH NON SLIP FINISHWITH 20MM SCREEDING

DRINKING FOUNTAIN ANDSINK WALL TO BE STEELFRAMEDAND CLAD IN SANDSTONE WITHMITRED ENDGES.

INTERNAL GUTTER WITH 1:100 FALLTO DOWNPIPE. GUTTER ON 100 X 50TREATED TIMBER FRAMING

1.0MM BUTYL RUBBER ROOFINGADHESIVE FIXED TO TO 18MMPLYWOOD INTERNAL GUTTER

STRUCTURAL STEEL BEAMTO ENGINEERS REQUIREMENTS

REUSED EXISTING DOWNPIPESHOWN DASHED BEHIND. DOWNPIPETO BE PLACED WITHIN WALL CAVITY.CONNECT TO EXISTING DRAINAGE.NEW WHITE POOWDERCOAT FINISHNEW CONCRETE FLOOR SLAB

WITH STEEL REINFORCINGMESH ON DPC ON HARDFILL

NEW ALUMINIUM LOUVRES TO BOTTOMOF EXISTING BRICK WALL. STEELFRAMING TO STRUCTURAL ENGINEERSREQUIREMENTS

ZINCALUME CAPPING OVEREXISTING BRICK WALL NATURALFINISH. CAPPING TO HAVE SLIGHTFALL FOR WATER RUN OFF

150 X 50 TREATED TIMBERBATTENS @ 150MM CRS. FIXEDTO 25X25MM ALUMINIUMCHANNELS BLACKPOWDERCOAT FINISH

COLORBOND CORRUGATED STEELROOFING WITH WHITE FINISH ONROOFING UNDERLAY

75 X 50 TREATED TIMBERPURLINS @ 600MM CRS. MAX.ON 150 X 50 TREATED TIMBERRAFTERS @ 600MM CRS. MAX.

TIMBER FASCIA BOARD WITH WHITEPAINT FINISH

SINK TOP TO BE STAINLESSSTEEL FINISH

RL 0.00

RL 4.900

RL 3.500

ROOF HIGH POINT

GROUND LEVEL

15° ROOF PITCH

FEMALE WC

FALL

TO

GU

TTER

RL 4.900ROOF LOW POINT

15° ROOF PITCH

DRAINCONNECT TO

EXISTINGCONNECT TO

EXISTINGCONNECT TO

EXISTING

GRAIN

GRAIN

0.0 0.5 1.0 2.0 3.0 3.0

SECTION 1:20 @ A2 A3.

1


Recommended