COVER PAGE & DRAWING INDEX R01 PROJECT NUMBER: PROJECT TITLE DRAWN CHECKED SCALE X'REF PATH(S) LEGAL DESCRIPTION CLIENT DESIGNED DATE COPYRIGHT (2008) COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMES REMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALL NOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THIS DRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION OR BUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED. ISSUE REVISION NO. DATE DESCRIPTION INITIAL REV. STEVEN HALLS . 28042 HIGHWAY 11 RED DEER, ALBERTA, T4S 2L4 CONSTRUCTION UFA 200 BURNT LAKE BUSINESS PARK STEVEN HALLS 52'x58'x18' AIRPLANE HANGER CONSTRUCTION NOTE: CUSTOMER/CONTRACTOR CAN NOT ALTER THE CONSTRUCTION FROM THAT WHICH IS CONTAINED IN THIS SEALED DRAWING SET WITHOUT PRIOR APPROVAL OF THE ENGINEER WHO'S SEAL APPEARS HEREON. OWNER MUST PROVIDE UFA A COPY OF ALL PERMITS ISSUED WITH RESPECT TO THIS PROJECT. NOTE TO PLAN EXAMINER: THIS PLAN IS PREPARED TO PROVIDE STRUCTURAL DETAILS ONLY. MECHANICAL AND ELECTRICAL ENGINEERING IS TO BE PROVIDED BY OTHERS. PLEASE CONTACT DGH ENGINEERING DIRECTLY REGARDING PLAN REVIEW COMMENTS OR REQUIREMENTS FOR ADJUSTMENTS AT [email protected]
Transcript
Page 1: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

COVER PAGE &DRAWING INDEX

R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

STEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

STEVEN HALLS52'x58'x18'

AIRPLANE HANGER

CONSTRUCTION

NOTE:CUSTOMER/CONTRACTOR CAN NOT ALTER THECONSTRUCTION FROM THAT WHICH IS CONTAINED IN THISSEALED DRAWING SET WITHOUT PRIOR APPROVAL OF THEENGINEER WHO'S SEAL APPEARS HEREON. OWNER MUSTPROVIDE UFA A COPY OF ALL PERMITS ISSUED WITHRESPECT TO THIS PROJECT.

NOTE TO PLAN EXAMINER:THIS PLAN IS PREPARED TO PROVIDE STRUCTURALDETAILS ONLY. MECHANICAL AND ELECTRICALENGINEERING IS TO BE PROVIDED BY OTHERS. PLEASECONTACT DGH ENGINEERING DIRECTLY REGARDING PLANREVIEW COMMENTS OR REQUIREMENTS FORADJUSTMENTS AT [email protected]

hodden
Pencil
Page 2: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

PROPOSEDBUILDING3016 sq. ft.

LOT A,CAMROSE MUNICIPAL

AIRPORT

SERVICE ROAD

SE

RV

ICE

RO

AD

RUNWAY AREA

SITE PLAN -BLDG. LOT PLAN.

C1R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

AIRPLANE HANGERSTEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

BUILDING LOT PLAN

hodden
Pencil
Page 3: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

CODE ANALYSIS..

BC1R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

AIRPLANE HANGERSTEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

CODE SUMMARY:

OCCUPANCY CLASSIFICATIONS: GROUP F, DIVISION 3LOW HAZARD INDUSTRIAL

BUILDING AREA: 280 SQ MBUILDING HEIGHT: 1 STOREYCONFORMANCE SECTIONS: 3.2.2.78COMBUSTIBLE CONSTRUCTION: PERMITTEDFIRE-FIGHTER ACCESS: NEEDED ON 1 SIDEOCCUPANT LOAD: 6

PARTICULAR CONSIDERATIONS:

THIS PROJECT CONSISTS OF NEW CONSTRUCTION OF AN AIRPLANEHANGER (STORAGE GARAGE F3 OCCUPANCY).

THE EXPOSING BUILDING FACE TOWARDS THE NORTH SIDE MUST BECLAD WITH NON-COMBUSTIBLE EXTERIOR SIDING AND BE BUILT TO HAVEA FIRE RESISTANCE RATING OF 60 MINUTES.

THE EXPOSING BUILDING FACE OF THE NORTH SIDE HAS AN AREA OF 86SQUARE METERS, WITH A LIMITING DISTANCE OF 2.5 METERS, FORALLOWABLE OPENINGS OF 11%. THE LIMITING DISTANCE FOR THEEXPOSING BUILDING FACE OF THE WEST HAS BEEN DETERMINED FROMTHE CENTER OF THE RUNWAY AREA RATHER THAN TO THE LOT LINE.

THE EXPOSING BUILDING FACE OF THE EAST SIDE HAS AN AREA OF 77SQUARE METERS, WITH A LIMITING DISTANCE OF 9 METERS, FORALLOWABLE OPENINGS OF 18%.

THE MEZZANINE AREA IS NOT CONSIDERED A STOREY. THE ENCLOSEDROOMS ON THE MEZZANINE ARE LESS THAN 10% OF THE FLOOR AREA INWHICH IT IS LOCATED.

THE OCCUPANCY CLASSIFICATION OF THIS BUILDING IS F3 LOW-HAZARDINDUSTRIAL. THEREFORE THE QUANTITY OF COMBUSTIBLE MATERIAL TOBE STORED INSIDE THE BUILDING MUST BE LIMITED TO NO MORE THAN 10POUNDS PER SQUARE FOOT OF FLOOR AREA, AND REPAIR OF MOTORVEHICLES IS NOT A PERMITTED USE.

OCCUPANT LOAD:

THE TOTAL OCCUPANT LOAD OF 6 HAS BEEN DETERMINED BY TABLE3.1.17.1.

FIRE-RATED ASSEMBLIES:

MEZZANINE ASSEMBLIES SHALL HAVE A FIRE-RESISTANCE RATING OF 45MINUTES.

FIRE SEPARATIONS:

PARTITIONS THAT ARE TO BE FIRE SEPARATIONS ARE INDICATED ON THEPLANS AS SHOWN ON THE LEGEND.

EXIT STAIRWELLS ARE TO BE SEPARATED FROM ADJACENT SPACES BY AFIRE SEPARATION OF 45 MINUTES.

ROOMS CONTAINING FUEL-FIRED APPLIANCES SHALL BE SEPARATEDFROM ADJACENT SPACES BY A FIRE SEPARATION OF 60 MINUTES.

ROOMS USED TO STORE JANITORIAL SUPPLIES SHALL BE SEPARATEDFROM ADJACENT SPACES BY A FIRE SEPARATION OF 60 MINUTES.

PENETRATIONS:

BUILDING SERVICES THAT PENETRATE A FIRE SEPARATION, OR AMEMBRANE FORMING PART OF A FIRE-RATED ASSEMBLY, SHALLCONFORM TO SECTION 3.1.8 'FIRE SEPARATIONS AND CLOSURES' ANDSECTION 3.1.9 'BUILDING SERVICES AND FIRE RATED ASSEMBLIES.'

FIRE DAMPERS ARE TO BE PROVIDED ON ALL DUCTS PENETRATING A FIRESEPARATION OR A FIRE-RATED ASSEMBLY.

FIRE-STOP FLANGES ARE TO BE PROVIDED ON ALL COMBUSTIBLE PIPINGPENETRATING A FIRE SEPARATION OR A FIRE-RATED ASSEMBLY.

ALL PIPING ENCLOSED WITHIN A FIRE-RATED ASSEMBLY IS TO BENON-COMBUSTIBLE.

PIPING, WIRING, CONDUIT OR RACEWAYS PENETRATING A MEMBRANEWHICH IS PART OF A FIRE SEPARATION OR A FIRE-RATED ASSEMBLYSHALL BE SEALED WITH A FIRE-STOP SYSTEM.

WRITTEN DESCRIPTIONS (EG CATALOGUE CUTS) OF ALL FIRE DAMPERS,FIRE-STOP CAULKINGS AND OTHER FIRE-STOP SYSTEMS, ARE TO BESUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO INSTALLATION.

INTERSECTIONS OF ASSEMBLIES:

WHERE A PARTITION ASSEMBLY OR A WALL ASSEMBLY INTERSECTS WITHA RATED FLOOR OR CEILING ASSEMBLY, THE INTERSECTION IS TO BETREATED WITH FIRE-SEALANT MATERIAL TO MAINTAIN THE FIRERESISTANCE RATING.

WRITTEN DESCRIPTIONS (EG CATALOGUE CUTS) OF THE FIRE-STOPMATERIALS ARE TO BE SUBMITTED TO THE ENGINEER FOR APPROVALPRIOR TO INSTALLATION.

EGRESS AND EXITS:

THE TRAVEL DISTANCE FROM ANY LOCATION IN THE BUILDING TO THENEAREST EXIT SHALL BE NO MORE THAN 98 FT (30 M).

THE TRAVEL DISTANCE FROM ANY LOCATION ON THE MEZZANINE TO THENEAREST EGRESS STAIR SHALL BE NO MORE THAN 50 FT (15 M).

EMERGENCY LIGHTING IS TO BE PROVIDED.

STAIRS SHALL HAVE HANDRAILS BOTH SIDES CONFORMING TO 3.4.6.4.

STAIR TREADS AND RISERS SHALL CONFORM TO 3.4.6.7, WITH A MINIMUMRUN OF 11” (280 MM) AND MAXIMUM RISE OF 7” (180 MM).

LANDINGS SHALL BE PROVIDED AT THE TOP AND BOTTOM OF EACH EXITSTAIR AND ACCORDING TO 3.4.6.3, WITH A LENGTH AT LEAST EQUAL TOTHE WIDTH OF THE STAIR OR 43” (1100 MM).

A MINIMUM CLEARANCE OF 12” (300 MM) SHALL BE PROVIDED BETWEENTHE PATH OF THE LATCH EDGE OF A DOOR IN ITS SWING AND ANY STAIRNOSING.

HEADROOM CLEARANCE ALONG ANY MEANS OF EGRESS SHALL BE ATLEAST 82” (2100 MM) EXCEPT AT DOORS 80” (2030 MM). CLEAR HEADROOMUNDER CLOSERS AT DOORS MUST BE AT LEAST 78” (1980 MM).

LOCKING, LATCHING AND OTHER FASTENING DEVICES AT EXIT DOORSSHALL BE INSTALLED NO HIGHER THAN 48” (1200 MM) ABOVE THE FLOORAND SHALL PERMIT THE DOOR TO BE OPENED READILY FROM THE INSIDEWITH NOT MORE THAN ONE RELEASING OPERATION AND WITHOUT KEYS,SPECIALIZED DEVICES OR SPECIALIZED KNOWLEDGE.

INTERIOR FINISHES:

THE INTERIOR PARTITION AND CEILING FINISHES MUST HAVE A FLAMESPREAD RATING OF NO MORE THAN 150, EXCEPT IN EXIT STAIRWELLSWHERE THE LIMIT IS 25, AND CORRIDORS WHERE THE LIMIT IS 25 ON THECEILING AND 75 ON THE PARTITIONS.

BARRIER-FREE ACCESS:

A BARRIER-FREE PATH OF TRAVEL SHALL BE PROVIDED FROM THEBARRIER-FREE PARKING STALL, THROUGH THE FRONT ENTRANCE,THROUGHOUT THE GROUND STOREY AND INTO THE BARRIER-FREEWASHROOM.

THE BARRIER-FREE PATH OF TRAVEL SHALL CONFORM TO 3.8, WITH ANUNOBSTRUCTED WIDTH NOT LESS THAN 36.5 ” (920 MM) ON THE INTERIORAND 44” (1100 MM) AT THE EXTERIOR. THE WALKING SURFACE SHALL BESTABLE, FIRM AND SLIP-RESISTANT, WITH NO OPENINGS THAT PERMITTHE PASSAGE OF A SPHERE ½” IN DIAMETER, AND NO VERTICAL STEP ORTHRESHOLD HIGHER THAN ½”.

LANDINGS 5 FT X 5 FT (1500 X 1500) SHALL BE PROVIDED IN RAMPS AT ANYDOORWAYS AND AT THE TOP AND BOTTOM.

DOORWAYS SHALL HAVE A CLEAR WIDTH WITH THE DOOR IN THE OPENPOSITION OF AT LEAST 31.5” (800MM).

DOOR HARDWARE SHALL NOT REQUIRE TIGHT GRASPING AND TWISTINGOF THE WRIST FOR OPERATION. CLOSERS SHALL CONFORM TO 3.8.3.3 (7)AND (10).

GUARDS:

GUARDS CONFORMING TO 3.3.1.17 AND 4.1.10.1, AT LEAST 42” (1070 MM)HIGH, ARE TO BE PROVIDED AT UNPROTECTED OPENINGS OR EDGES INFLOORS OR ROOFS AND AT BALCONIES, STAIRS AND RAMPS.

ATTIC ACCESS:

AN ACCESS PANEL AT LEAST 22” X 36” (550 MM X 900 MM) IS TO BEPROVIDED TO ANY CONCEALED ROOF SPACE HIGHER THAN 2' (600 MM).

ATTIC VENTING:

TOTAL FREE VENT AREA TO THE ATTIC IS TO BE AT LEAST 1440 SQUAREINCHES. THE MINIMUM ALONG THE LOW EAVES IS TO BE 720 SQUAREINCHES AND THE MINIMUM ALONG THE PEAK IS TO BE 360 SQUAREINCHES.

MECHANICAL VENTILATION:

IT IS A CODE REQUIREMENT THAT ALL OCCUPIED SPACES BE PROVIDEDWITH FRESH AIR BY MECHANICAL VENTILATION.

FRESH AIR CAN BE PROVIDED TO THE AIRPLANE PARKING AREA BYNATURAL VENTILATION RATHER THAN MECHANICAL VENTILATION DUE TOTHE LOW OCCUPANT LOAD (LESS THAN 1 PERSON PER 40 SQUAREMETERS OF FLOOR SPACE).

FRESH AIR BY MECHANICAL VENTILATION SHALL CONFORM TO ASHRAE 62UNLESS OTHERWISE STIPULATED.

PORTABLE FIRE EXTINGUISHERS:

ALL PORTABLE FIRE EXTINGUISHERS ARE TO BE TYPE ABC INSTALLEDEITHER IN SURFACE-MOUNTED CABINETS OR ON WALL-MOUNT BRACKETSWITH PLASTIC HOODS TO PROTECT FROM DUST AND MOISTURE. THEMINIMUM CAPACITY OF EACH EXTINGUISHER IS TO BE AT LEAST 2A AND10B; AT LEAST 2 ARE TO BE PROVIDED, AS SHOWN ON THE PLANS ANDDISTRIBUTED SO THAT AT LEAST ONE IS ACCESSIBLE WITHIN 75 FEET OFANY LOCATION.

WATER FOR FIRE-FIGHTING:

WATER FOR FIRE FIGHTING IS AVAILABLE FROM THE PUBLIC UTILITYLOCATED 45 M SOUTH-WEST OF THE PROPOSED BUILDING LOCATION.

ACCESS FOR FIRE-FIGHTING VEHICLES:

THE ACCESS ROUTE FOR FIRE-FIGHTING VEHICLES MUST BE SUCH THATNEITHER THE DISTANCE FROM THE BUILDING FRONT ENTRANCE TO THEPUMPER VEHICLE NOR THE DISTANCE FROM THE PUMPER VEHICLE TOTHE HYDRANT WILL EXCEED 150 FEET.

SHOP DRAWING REVIEWS:

CONSTRUCTION OF THIS PROJECT IS TO BE CERTIFIED BY DGHENGINEERING FOR CODE COMPLIANCE.

SHOP DRAWINGS OR CATALOGUE CUTS, FOR ALL COMPONENTSAFFECTING CODE COMPLIANCE, ARE TO BE SUBMITTED TO DGHENGINEERING FOR REVIEW. SUBMISSION IS TO BE MADE BY THEGENERAL CONTRACTOR (NOT THE SUB-TRADE) AND AN ALLOWANCE IS TOBE MADE OF 7 WORKING DAYS FOR REVIEW. COMPONENTS REQUIRINGSHOP DRAWING REVIEW IN THIS PROJECT INCLUDE:

1. ROOF TRUSSES

2. PENETRATIONS THROUGH FIRE SEPARATIONS (SUCH AS FIREDAMPERS AND CAULKINGS)

3. PRE-FABRICATED STAIRS4. EMERGENCY LIGHTING

SITE VISITS:

CONSTRUCTION OF THIS PROJECT IS TO BE CERTIFIED BY DGHENGINEERING FOR CODE COMPLIANCE.

DURING CONSTRUCTION, SITE VISITS ARE TO BE MADE BY DGHENGINEERING AT THE EVENTS LISTED BELOW. THE CONTRACTOR IS TONOTIFY DGH ENGINEERING AT LEAST 2 WORKING DAYS PRIOR TO EACHOF THESE SITE VISITS:

1. FOOTING & FLOOR REBAR2. WALL FRAMING3. ROOF FRAMING & BRACING4. ON COMPLETION

hodden
Pencil
Page 4: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

CODE ANAYLSISPLANS & DETAILS.

BC2R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

AIRPLANE HANGERSTEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

FLOOR PLAN - MAIN

FLOOR PLAN - MEZZANINE

LAVATORIES

WATER CLOSETS

BARRIER FREE WASHROOM FIXTURES

DETAIL - TYPICAL STAIR

CODE ANALYSIS EQUIPMENT & SPACE RATING SCHEDULE

ITEM SYMBOL REMARKS

F

F

hodden
Pencil
Page 5: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

FLOOR PLAN -OVERVALL.

B1R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

AIRPLANE HANGERSTEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

FLOOR PLAN - MAIN

:

FLOOR PLAN - MEZZANINE

2S3

1 2 3

1

1

1

1

1

1

1

1

1

3

3

3

3

1S3

3

2

2 2 1

1

1

hodden
Pencil
Page 6: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

.

.B2

R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

AIRPLANE HANGERSTEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

SOUTH ELEVATION

NORTH ELEVATION

WEST ELEVATION

EAST ELEVATION

hodden
Pencil
Page 7: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

FOUNDATION PLAN -OVERALL.

S1R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

AIRPLANE HANGERSTEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

hodden
Pencil
Page 8: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

L-3

L-4

L-1 L-2 L-2 L-2 L-2 L-2 L-1

L-1 L-1L-1

L-1

L-1

ROOF FRAMING &FLOOR FRAMINGPLAN & NOTES

S2R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

AIRPLANE HANGERSTEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

FLOOR PLAN - MAIN

FLOOR PLAN - MEZZANINE

LINTEL SCHEDULE

MARK MAX. LENGTH LINTEL REQUIREMENTS

hodden
Pencil
Page 9: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

BUILDING SECTION..

S3R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

AIRPLANE HANGERSTEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

BUILDING SECTION

HOLD DOWN ANCHOR

MECH RM. SECTION

hodden
Pencil
Page 10: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

STITCH SCREW SCHEDULEROOF No. 12x¾" HWH @ 12" o/c

END WALL No. 12x¾" HWH @ 6" o/cSIDE WALL No. 12x¾" HWH @ 24" o/c

EDGE PURLIN SPLICE DETAIL

ROOF PURLIN DETAILVERTICAL SWAY-BRACING& ANCHOR-BRACING DETAIL

ROOF GABLE BRACING DETAILCLADDING OVERLAP DETAIL

TYPICAL SCREW DETAIL

ROOF METAL SCREW DETAIL

ROOF FRAMING.

S4R01

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

AIRPLANE HANGERSTEVEN HALLS

.28042 HIGHWAY 11RED DEER, ALBERTA, T4S 2L4

CONSTRUCTIONUFA

200 BURNT LAKE BUSINESS PARK

hodden
Pencil
Page 11: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

S5.1R01

AIRPLANE HANGERSTEVEN HALLS

28042 HIGHWAY 11

CONSTRUCTION

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

Page 12: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

S5.2R01

AIRPLANE HANGERSTEVEN HALLS

28042 HIGHWAY 11

CONSTRUCTION

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

Page 13: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting

S5.3R01

AIRPLANE HANGERSTEVEN HALLS

28042 HIGHWAY 11

CONSTRUCTION

PROJECT NUMBER:

PROJECT TITLE

DRAWN CHECKED

SCALE X'REF PATH(S)

LEGAL DESCRIPTION

CLIENT

DESIGNED

DATE

CO PY RIG H T (2008)COPYRIGHT RESERVED. THIS DRAWING AND DESIGN IS AND AT ALL TIMESREMAINS THE EXCLUSIVE PROPERTY OF DGH ENGINEERING LTD. AND SHALLNOT BE USED WITHOUT THE ENGINEER'S CONSENT IN WRITING. THECONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALLERRORS AND OMISSIONS TO THE ENGINEER IN WRITING. DO NOT SCALE THISDRAWING. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION ORBUILDING PERMIT PURPOSES UNTIL SEALED AND SIGNED.

ISSUE

REVISION

NO. DATE DESCRIPTION INITIALREV.

Page 14: CONSTRUCTION - Moose and Dochalls.md/hangar/2008-11-12 Plan Set.pdf · steven halls 28042 highway 11 . red deer, alberta ... door hardware shall not require tight grasping and twisting