1 INTRODUCTION
2 SYSTEMS SELECTOR
3 SYSTEMS DESCRIPTION
SYSTEM 1 / IMPERMAX BASICSYSTEM 2 / IMPERMAX PLUSSYSTEM 3 / IMPERMAX DECORSYSTEM 4 / IMPERMAX PARKSISTEMA / IMPERMAX D
4 KRYPTON CHEMICALS PROJECTS
5 QUALITY ASSURANCE / ACCREDITATIONS
CD CONTENTS
1 EUROPEAN TECHNICAL APPROVAL ETA Nº 06/0263
2 LAB TESTS REPORT ETA Nº 06/0263
3 IMPERMAX INSTALLATION MANUAL
4 ADDITIONAL QUALITY CERTIFICATES
IMPERMAXExternal fire exposure test.Test 1 / Method: UNE-ENV 187:2003
IMPERMAX AQUAMigration tests for products in contact with drinking water for humanconsumption as per EEC directive 98/83/CE
IMPERTRANS 60Tensile strength and elongation as per UNE EN 527-3Accelerated artificial ageing as per UNE EN ISO 4892/3Waterproofing as per UNE EN 1928Water vapour permeability as per UNE EN ISO 7783-1 and UNE EN ISO 7783-2
02/03
04/05
06
06/0910/1112/1314/1516/19
20/23
24
INTRODUCTION
KRYPTON CHEMICALSSYSTEMS ANDSOLUTIONSKRYPTON CHEMICAL provides tospecifiers, architects, builders andproperty owners a high level oftechnical assistance, guidance andsupport in all phases of Projects,through to completion. KRYPTONsystems are well known all over theWorld for their remarkable successstories in waterproofing. Supported bylong term guarantees, as well as byan extended network of ApprovedInstallers, these systems offer a highlevel of security in all projects.
VERSATILE SOLUTIONSIN WATERPROOFINGKRYPTON CHEMICAL offers a widerange of products in liquid form, whichdo not require flame or torches in theirapplication, can be reinforced whereappropriate, and are suitable forproviding solutions in the mostdemanding situations. All of thesesystems are based on the mostadvanced polymer chemistry, andprovide excellent technicalperformance with exceptional integrityin waterproofing.
A RAYSTON SYSTEMFOR EVERY NEED• Roof Refurbishment: Oursystems are ideal for application onalmost any substrate. These productsoften avoid the need to removewaterproofing elements usedpreviously. IMPERMAX membranesprovide a custom made liner to thearea treated, forming a “skin”, whichis totally adhered to it.
• New roofs: The great majority ofroofs are treated with bitumen or otherlow technology systems. Theseproducts may offer a quick andeconomic solution, but also tend tofail prematurely. For modern flat orinverted roofs which are often complexin design and include vents / airconditioning units etc. KRYPTONroofing systems offer an economiclong term solution. This is of evengreater benefit where there is hightraffic volume or the roof has asecondary use - car park or roof gardenfor example-.
COMPARISONWITH TRADITIONALMATERIALS
Even though liquid waterproofingsystems have been in the marketfor the last 30 years, they are stillconsidered “new” technologyproducts, especially if comparedwith products based onthermoplastic sheets or bitumen.
Laying traditional systems normallyrequires:
• Gas burning torches to meltasphalt.
• Handling liquid asphalt attemperatures above 150ºC.
• Welding by use of hot air or gasburning torches.
Temperatures reached by suchsystems may well exceed 150 ºC,or in the case of welding by hot air,may reach beyond 1000 ºC.
Such works normally imply highinsurance costs, and Health andSafety risk hazards. In the U.K., itis demanded that companieshandling such systems employsevere safety measures during andafter the execution of projects, asin many cases, treated roof areasmay even ignite a few hours aftercompletion of work.
For this reason, in North Europeancountries bitumen based systemsare being progressively abandonedand replaced by liquid cold appliedsystems.
For the architect, owner, builder orcontractor, Krypton Chemicalsystems provide a high degree ofsecurity, and clear benefits in termsof health and safety at work.
IMPERMAX waterproofingmembrane has obtained a CLASSBROOF(t1) classification, accordingto EEC regulation BS EN 13501-5:2005, which relates to differentmaterials behaviour when exposedto external fire.
Thanks to the total absence of jointsand overlaps, critical points oftraditional waterproofing solutionsare totally eliminated, providing awaterproofing solution which iscontinuous and homogeneous,protects real estate assets in thelong term, and is easily adapted toany kind of construction.
POSSIBLE SUBSTRATES
Concrete / cementMetal roofWood
POSSIBLE SOLUTIONS
Flat roof no Traffic· With heavy protection (tiles / slabs)· Traditional roof· Inverted roof
With Light protection / “exposed”
Flat roof with Traffic· Traditional Roof· Inverted Roof with traffic
Parking decks for vehicles
Roof gardens
CONCLUSION
With RAYSTON systems , it ispossible to cover and satisfy allpossible roofing needs.
IMPERMAX systems satisfyall needs in roof waterproofing
PAGE 03
SYSTEMS SELECTOR
Please use the table attached, to select the systemthat best fits your project requirements.
In the following pages, you will find a detailedoverview of each system, including all the differentcomponents that make it, an explanation of every
step to follow in laying these systems, and themain advantages gained from specifying these
systems.
It has to be made clear that all of these systemscome from a main / base IMPERMAX system,approved for use in the EEC according to ETA
nº 06/0263. Impermax has many different uses,the following system selector outlines application
methods and ancilliary products to be used toachieve the optimum result.
PAGE 04
NOTE: IMPERMAX D is a detail treatment system used in every IMPERMAX KRYPTON CHEMICAL System.
SYSTEM SELECTION CHART
USESIMPERMAX
BASICIMPERMAX
PLUSIMPERMAX
DECORIMPERMAX
PARKIMPERMAX
DIMPERMAX
MUR
Roofs
Details
Repairs and maintenance
Plants / Flowers
Basements
KIND OF CONSTRUCTION
x x x x
x
x
x
x
Concrete
Metal
Wood
x x x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
RECOMMENDEDAPPLICATION
FLAT ROOFSNO TRAFFIC
Traditional roofs heavy protection
Warm roofs heavy protection
Exposed roofs / light protection
FLAT ROOFSTRAFFIC
Traditional roofs
Warm roofs with traffic
PARKING DECKS
ROOF GARDENS
PLANTS/FLOWERS/PATIOS
BASEMENTS
x
x x
x
x
x x
x
x
x
x
COLOURS /POSSIBLE FINISHES
Dark Red, Light Red,Grey 7001
RAL Colour chart
Quartz imitation /Coloured flakes (Chips)
x
x x
x
x
x
SYSTEMS DESCRIPTIONSYSTEM 1IMPERMAX BASIC
TRADITIONAL ROOF / with GRAVEL as Heavy Protection
1. Substrate2. Insulation/ Slope formation3. Primers4. Impermax Basic5. Geomax Protec6. Gravel
WARM ROOF / with GRAVEL as Heavy Protection
1. Substrate2. Slope formation3. Primers4. Impermax Basic5. Insulation (XPS)6. Geomax Protec7. Gravel
12
45
6
12
45
67
3
3
PAGE 06
TRADITIONAL ROOF / with TILE as Heavy Protection
1. Substrate2. Insulation/ Slope formation3. Primers4. Impermax Basic5. Geomax Protec6. Mortar7. Tile
WARM ROOF FOR TRAFFIC
1. Substrate2. Insulation/ Slope formation3. Primers4. Impermax Basic5. Geomax Protec6. Filtering / Insulating Tiles
12
4 5 67
3
12 3
45
6
PAGE 07
ROOFING SOLUTIONS BASED ON IMPERMAX BASIC
IMPERMAX BASIC system consists of following elements (according to ETA 06/0263):
PRIMERSIMPERMAX+ SOLVENT PU PRIMER
HUMIDITYPRIMER
Dry-Porous Concrete /mortar / cement
Vitrified ceramic or tile
Wet / Humid concrete /cement
Tiles / slabs with humidityunderneath
Steel / aluminium / metal
PVC / EPDM Single Ply
Asphalt
Brick
x
x
x
x
x
x
x
x
Substrates must always meet thefollowing minimum requirements,(without these it is impossible to applyIMPERMAX):
1. Levelled. Assuming there must alwaysbe some slope in all roofs, for waterevacuation.
2. Cohesive.
3. Regular.(In irregular substrates, it isimperative to reinforce the systemusing GEOMAX reinforcement textile).
4. Free from fissures and cracks,which must be treated beforehandusing GEOMAX reinforcementtextile.
5. Clean, dry, without dust or losematerials, free from grease, oil andany impurities.
WATERPROOFINGIMPERMAX must be applied(according to the Installation Manual)on the previously prepared surface,at a minimum quantity of 2 Kg/m2,in order to reach a minimum thicknessof 1,6mm.
TREATMENT OF CRITICALSPOTS AND DETAILSSee IMPERMAX D prescription.
FINISHIMPERMAX BASIC systems arenormally covered with tile/slabs orgravel, depending on the specific useand specification for that roof, andits user load. It is always advised toprotect this system with a layer of200 g/m2 GEOTEXTILE (GEOMAXPROTEC), so it is not damaged duringand alter installation.
PAGE 08
PRIMERS
The primer selected depends on thenature of the substrate, and thecondition of it, please refer to thefollowing table.
PERFORMANCE
IMPERMAX liquid waterproofing membrane provides (as per ETA nº 06/0263)the following performance levels:
NOTE: User load, as per EOTA (European Organisation for Technical Approvals)Technical Report nº 7 (Static Indentation), sets up the following values:
P1: Maximum load that product can withstand under static indentation = 7 Kg/cm2.P3: Maximum load that product can withstand under static indentation = 21 Kg/cm2.
External fire performance
Fire Reaction
Expected working life
Climatic zone of use
User loads
Roof slopes
Minimum surface temperatures
Maximum surface temperatures
Broof (t1)
F
W2 (10 Years)
S (Severe)
P3 –TH2 / P1-TH4
S1 – S4
TL3 (- 20ºC)
TH4 (90ºC) / ExposedTH2 (60ºC) / Heavilyprotected or uninsulated
ADVANTAGES
The use of IMPERMAX Basic systemprovides the following advantages.
1. Provides a totally continuousmembrane, without joints andoverlaps.
2. Totally adhered system. It does notallow water to flow between layers.
3. Elastic membrane. Bridges overfissures in substrate and resists fatiguemovement (according to EOTA TR-nº 8).
PAGE 09
SYSTEM 2IMPERMAX PLUS
The IMPERMAX PLUSsystem is applied usingfollowing elements(as per ETA nº06/0263):
PRIMERS
The primer selected depends on thenature of the substrate, and thecondition of it, according to the tablebelow.
Substrates must always meet thefollowing minimum requirements,(without these it is impossible to applyIMPERMAX):
1. Levelled. Assuming there mustalways be some slope in all roofs, forwater evacuation.
2. Cohesive.
3. Regular. (In irregular substrates, itis imperative to reinforce the systemusing GEOMAX reinforcement textile).
4. Free from fissures and cracks,which must be treated beforehandusing GEOMAX reinforcement textile.
5. Clean, dry, without dust or losematerials, free from grease, oil andany impurities.
FLAT ROOF WITHLIGHT PROTECTION(exposed)
1. Substrate2. Insulation / Slope formation3. Primers4. Impermax5. Impertrans 60 with colour pigment
12 3
45
PAGE 10
PRIMERSIMPERMAX +
SOLVENTPU
PRIMERHUMIDITYPRIMER
Dry-Porous Concrete /mortar / cement
Vitrified ceramic or tile
Wet / Humid concrete /cement
Tiles with humidityunderneath
Steel / aluminium / metal
PVC / EPDM Single Ply
Asphalt
Brick
x
x
x
x
x
x
x
x
WATERPROOFING
IMPERMAX must be applied(according to the Installation Manual)on the previously prepared surface,at a minimum quantity of 2 Kg/m2,in order to reach a minimum thicknessof 1,6mm.
TREATMENT OF CRITICALSPOTS AND DETAILS
See IMPERMAX D prescription.
FINISH
IMPERMAX PLUS System includes atop coat layer of Aliphatic Polyurethaneresin IMPERTRANS 60, combinedwith colour pigments. This finishinglayer (Top Coat) provides greaterresistance to UV light and weathering,as well as good aesthetics / colourstablility aspect.
The top coat consists of a layer ofIMPERTRANS 60 (300 gr/m2),applied on the final coat ofIMPERMAX at least 24 hrs after ithas been applied.
PERFORMANCE
IMPERMAX liquid waterproofing membrane provides (as per ETA nº 06/0263)the following performance levels:
NOTE: User load, as per EOTA (European Organisation for Technical Approvals)Technical Report nº 7 (Static Indentation), sets the following values:
P1: Maximum pressure supported by the product = 7 Kg/cm2.P3: Maximum pressure supported by the product = 21 Kg/cm2.
External fire performance
Fire Reaction
Expected working life
Climatic zone of use
User loads
Roof slopes
Minimum surface temperatures
Maximum surface temperatures
Broof (t1)
F
W2 (10 Years)
S (Severe)
P3 –TH2 / P1-TH4
S1 – S4
TL3 (- 20ºC)
TH4 (90ºC) / ExposedTH2 (60ºC) / Heavilyprotected or uninsulated
ADVANTAGES
The use of IMPERMAX PLUS systemprovides the following advantages:
1. Provides a totally continuousmembrane, without joints andoverlaps.
2. Totally adhered system. It does notallow water to flow between layers.
3. Elastic membrane. Bridges overfissures in substrate and resists fatiguemovement (according to EOTA TR-nº 8).
4. Allows for an economic treatmentand maintenance of new or existingroofs, since it can be left exposedwithout the need for heavy /cumbersome top layers of gravel, tiles,etc. (as per ETA nº 06/0263).
5. Provides an aesthetic / decorativefinish, that can even be anti-thermic,if Impertrans 60 is combined withWHITE colour.
PAGE 11
SYSTEM 3IMPERMAX DECOR
The IMPERMAX DECORsystem is applied usingfollowing elements(according to ETAnº 06/0263):
PRIMERS The primer selected depends on thenature of the substrate, and the stateof it, according to the following table.
Substrates must always meet thefollowing minimum requirements,(without these it is impossible to applyIMPERMAX):
1. Levelled. Assuming there mustalways be some slope in all roofs, forwater evacuation.
2. Cohesive.
3. Regular. (In irregular substrates, itis imperative to reinforce the systemusing GEOMAX reinforcement textile).
4. Free from fissures and cracks,which must be treated beforehandusing GEOMAX reinforcement textile.
5. Clean, dry, without dust or rests oflose materials, free from grease, oiland any impurities.
FLAT ROOF WITHLIGHT PROTECTION(exposed)
1. Substrate2. Insulation / Slope formation3. Primers4. Impermax5. Colodur 60 (clear)6. Flakes / Quartz granules +Colodur 60 (clear)
1 24
56
3
Coloured quartz permits a wide variety of combinations. Please check withKrypton Chemical’s technical team for more information.
PAGE 12
WATERPROOFING
IMPERMAX must be applied(according to the Installation Manual)on the previously prepared surface,at a minimum quantity of 2 Kg/m2,in order to reach a minimum thicknessof 1,6mm.
TREATMENT OF CRITICALSPOTS AND DETAILS
See IMPERMAX D prescription
FINISH
System IMPERMAX DECOR conveys afinish made of the following elements,once the IMPERMAX layer is fully cured:
a. Extension of a bonding layer of 300g/m2 of resin COLODUR 60.
b. Saturation of this liquid layer withquartz sand or colour flakes, on thedesired tonality. (up to 2 Kg/m2).
c. Elimination of non adhered particlesor sand.
d. The quartz sand maybe polishedby means of a mechanical machine(optional).
e. Final sealing with a top coat ofclear COLODUR 60 (300 g/m2).
ADVANTAGES
The use of IMPERMAX DECOR systemprovides the following advantages:
1. Provides a totally continuousmembrane, without joints andoverlaps.
2. Totally adhered system. It will notallow water to flow between layers.
3. Elastic membrane. Bridges overfissures in substrate and resistsfatigue movement (according to EOTATR-nº 8).
4. Provides an economic / aestheticfinish without the need for a heavier/ expensive treatment of tile or gravel(product may be left exposed as perETA nº 06/0263).
5. Elegant / anti-skid finish availablein various colours.
PERFORMANCE
IMPERMAX DECOR liquid waterproofing system provides (as per ETA nº 06/0263)the following performance levels:
NOTE: User load, as per EOTA (European Organisation for Technical Approvals)Technical Report nº 7 (Static Indentation), sets out the following values:
P1: Maximum load that product can withstand under static indentation = 7 Kg/cm2.P3: Maximum load that product can withstand under static indentation = 21 Kg/cm2.
External fire performance
Fire Reaction
Expected working life
Climatic zone of use
User loads
Roof slopes
Minimum surface temperatures
Maximum surface temperatures
Broof (t1)
F
W2 (10 Years)
S (Severe)
P3 –TH2 / P1-TH4
S1 – S4
TL3 (- 20ºC)
TH4 (90ºC) / ExposedTH2 (60ºC) / Heavilyprotected or uninsulated
PAGE 13
Dry-Porous Concrete /mortar / cement
Vitrified ceramic or tile
Wet / Humid concrete /cement
Tiles with humidityunderneath
Steel / aluminium / metal
PVC / EPDM Single Ply
Asphalt
Brick
x
x
x
x
x
x
x
x
PRIMERSIMPERMAX +
SOLVENTPU
PRIMERHUMIDITYPRIMER
SYSTEM 4IMPERMAX PARK
The IMPERMAX PARKsystem is applied usingfollowing elements(according to ETAnº 06/0263):
PRIMERS
The primer selected depends on thenature of the substrate, and the stateof it, according to the following table.
Substrates must always meet thefollowing minimum requirements,(without these it is impossible to applyIMPERMAX):
1. Levelled. Assuming there mustalways be some slope in all roofs, forwater evacuation.
2. Cohesive.
3. Regular. (NOTE: in irregularsubstrates, it is imperative to reinforcethe system using GEOMAXreinforcement textile).
4. Free from fissures and cracks,which must be treated beforehandusing GEOMAX reinforcement textile.
5. Clean, dry, without dust or rests oflose materials, free from grease, oiland any impurities.
FLAT ROOF FORPARKING DECKS
1. Substrate2. Insulation / Slope formation3. Primers4. Impermax5. Paviflex6. Granules (0,4 - 0,6mm) +
Colodur (RAL Colour)
1 24
56
3
PAGE 14
WATERPROOFING
IMPERMAX must be applied(according to the Installation Manual)on the previously prepared surface,at a minimum quantity of 2Kg/m2, inorder to reach a minimum thicknessof 1,6mm.
TREATMENT OF CRITICALSPOTS AND DETAILS
See IMPERMAX D prescription, forevery different project.
FINISH
IMPERMAX PARK System implies atreatment of the previouslywaterproofed area with the followingelements:
a. Laying a protection (protective)flexible floor made of a 2 componentsolvent free Polyurethane resinPAVIFLEX. Typical thickness is 2 mm(2,6Kg/m2).
b. Extension of a bonding layer of300 g/m2 of resin COLODUR 60.
c. Saturating this bonding layer withsand / quartz granules in size 0,4 -0,9 mm (or bigger, depending on theanti-skid effect desired).
d. Removal of the free / non adheredgranules.
e. Final sealing / top coat with resinCOLODUR 60 in the desired RALcolours (300 g/m2).
ADVANTAGES
The use of IMPERMAX PARK systemprovides the following advantages:
1. Provides a totally continuousmembrane, without joints andoverlaps.
2. Totally adhered system. It does notallow water to flow between layers.
3. Elastic membrane. Bridges overfissures in substrate and resistsfatigue movement (according to EOTATR-nº 8).
4. Provides a high resistance to vehicletraffic and to puncture, so it actuallybecomes the ideal system for car parkroofing decks.
5. Provides and anti-skid, aestheticflooring system that can be easilymaintained and repaired.
PAGE 15
Dry-Porous Concrete /mortar / cement
Vitrified ceramic or tile
Wet / Humid concrete /cement
Tiles with humidityunderneath
Steel / aluminium / metal
PVC / EPDM Single Ply
Asphalt
Brick
x
x
x
x
x
x
x
x
PRIMERSIMPERMAX +
SOLVENTPU
PRIMERHUMIDITYPRIMER
PERFORMANCE
IMPERMAX PARK liquid waterproofing system provides (as per ETA nº 06/0263)the following performance levels:
NOTE: User load, as per EOTA (European Organisation for Technical Approvals)Technical Report nº 7 (Static Indentation), sets out the following values:
P1: Maximum load that product can withstand under static indentation = 7 Kg/cm2.P3: Maximum load that product can withstand under static indentation = 21 Kg/cm2.
External fire performance
Fire Reaction
Expected working life
Climatic zone of use
User loads
Roof slopes
Minimum surface temperatures
Maximum surface temperatures
Broof (t1)
F
W2 (10 Years)
S (Severe)
P3 –TH2 / P1-TH4
S1 – S4
TL3 (- 20ºC)
TH4 (90ºC) / ExposedTH2 (60ºC) / Heavilyprotected or uninsulated
WATERPROOFING /TREATMENT
GENERAL ASPECTS:
1. In general, for system IMPERMAXD (treatment of critical points) it isalways advisable to reinforce themembrane using GEOMAXreinforcement textile.
2. Geomax geotextile must be usedwhere vertical faces encounterhorizontal faces and to dress sharpangles vertical or sloping sections willrequire thixotropic agent added to theImpermax.
3. The main objective is to alwaysensure total continuity and integrityof the membrane, helping to bypassobstacles and limitations in thewaterproofing area. It is important toalways observe the precautions asexplained in the INSTALLATIONMANUAL.
In each of the most common cases,it is advised to adopt the treatmentdescribed below.
SYSTEM 4IMPERMAX D
The IMPERMAX Dsystem, is mainly usedfor treatment of criticalpoints such asexpansion joints,fissures, vertical /horizontal encounters,etc. It is made of thefollowing elements (asper ETA nº 06/0263):
PRIMERS
The primer selected depends on thenature of the substrate, and the stateof it, according to the following table.
Substrate will always have thefollowing characteristics:
1. Cohesive
2. Regular
3. Clean, dry, free of dust and losematerials, exempt of grease, oils,etc.
PAGE 16
FINISH
IMPERMAX D is compatible with allthe different IMPERMAX systems.
ADVANTAGES
The use of IMPERMAX D systemprovides the following advantages:
1. Provides a totally continuousmembrane, without joints andoverlaps.
2. Totally adhered system. It does notallow water to flow between layers.
3. Elastic membrane. Bridges overfissures in substrate and resistsfatigue movement (according to EOTATR-nº 8).
4. It provides a total continuity in themembrane, making sure that allcritical points are treated properly.
PAGE 17
Dry-Porous Concrete /mortar / cement
Vitrified ceramic or tile
Wet / Humid concrete /cement
Tiles with humidityunderneath
Steel / aluminium / metal
PVC / EPDM Single Ply
Asphalt
Brick
x
x
x
x
x
x
x
x
PRIMERSIMPERMAX +
SOLVENTPU
PRIMERHUMIDITYPRIMER
PERFORMANCES
IMPERMAX D liquid waterproofing system provides (as per ETA nº 06/0263)the following performance levels:
NOTE: User load, as per EOTA (European Organisation for Technical Approvals)Technical Report nº 7 (Static Indentation), sets out the following values:
P1: Maximum load that product can withstand under static indentation = 7 Kg/cm2.P3: Maximum load that product can withstand under static indentation = 21 Kg/cm2.
External fire performance
Fire Reaction
Expected working life
Climatic zone of use
User loads
Roof slopes
Minimum surface temperatures
Maximum surface temperatures
Broof (t1)
F
W2 (10 Years)
S (Severe)
P3 –TH2 / P1-TH4
S1 – S4
TL3 (- 20ºC)
TH4 (90ºC) / ExposedTH2 (60ºC) / Heavilyprotected or uninsulated
SYSTEM 4IMPERMAX D /sketches
TREATMENT OF EXPANSION JOINTS AND FISSURES
1. Joint bottom (PE foam)2. GEOMAX3. IMPERMAX + GEOMAX4. PU sealant (low modulus)5. Separation layer (PE film)6. IMPERMAX + GEOMAX7. IMPERMAX
INSTALLATION OF GULLEYS
1. Impermax2. Gully3. Impermax
≥15cm CONCRETE
INTERIOR 3cm
20cm
10cm
7 3 4 6
1
2
5
4
2
5 6 7
1
3
PAGE 18
A CASE. LAYING WATERPROOFING ON INSULATION
A. Waterproofing MembraneB. Expanded concrete / MortarC. InsulationD. Vapour BarrierE. Concrete
B CASE. LAYING INSLUATION ON WATERPROOFING
A. Tiles / optional finishesB. Geomax (recommended)C. InsulationD. ImpermaxE. Expanded concrete / MortarF. Concrete
Treatment at the unionbetween vertical and horizontal areas.
IMPERMAX + GEOMAX
MORTAR
GEOMAX
GEOMAX
C
B
D
E
A
MORTAR
GEOMAX
IMPERMAX
F
D
A
B
E
CB
PAGE 19
Terrace · Foster Wheeler Reading
Gutter
Roof
Terrace · Foster Wheeler Reading
Airport · New terminal car park Airport · New terminal car park
Roof at DiageoRoof at Diageo
KRYPTON CHEMICAL SPAINKRYPTON CHEMICAL FRANCEKRYPTON CHEMICAL UK
Projects executed in several countries:Spain, UK, France, Netherlands, Germany, Portugal, Italy, Belgium...
Storm water tank Roof
Roof Fish pond
Pond
Pond
Pond
Foundations
PAGE 21
Drinking water tank
Sports complex
Terrace
Sports complex
Roof Residential building
Fountains
Water tank
Roof Industrial Building
Gardens
Gardens
Terrace · Foster Wheeler Reading
Residential building Roof
PAGE 22
Water Park
Airport roof
Bar roof
Rugby Club Terrace
Car dealership · Impermax Park
Aqua Pond
Water tank
Rugby Club
Impermax decor
PAGE 23
Roof
PAGE 24
Airport Roof
Airport car park
Restaurant Terrace
Industrial floor
Airport car park
Airport Roof
Roof
Roof Residential building
Ashtree House, Ashbrook Iane · Abbots Bromley, RugeleyWS15 3DW STAFFORDSHIRE / GREAT BRITAIN
Tel. 0044 1283 841 805 · Fax 0044 1283 841 [email protected] · www.raystonpu.com
MADE BY:
KRYPTON CHEMICAL S.L.Pol. Industrial Les Tàpies, C/ Martí i Franquès 12
43890 L'Hospitalet de l'Infant · TARRAGONA · SPAINTél. 0034 977 822 245 · Fax 0034 977 823 977
[email protected] · www.raystonpu.com