+ All Categories
Home > Documents > CONTEMPLATED CHANGE NOTICE CCN/CO No: 01 Architecture Ltd. 1100 - 111 Dunsmuir Street Vancouver BC...

CONTEMPLATED CHANGE NOTICE CCN/CO No: 01 Architecture Ltd. 1100 - 111 Dunsmuir Street Vancouver BC...

Date post: 20-Jun-2018
Category:
Upload: phamthien
View: 219 times
Download: 0 times
Share this document with a friend
11
Stantec Architecture Ltd. 1100 - 111 Dunsmuir Street Vancouver BC V6B 6A3 Tel: (604) 696-8000 Fax: (604) 696-8100 Project: Relay T2626 Montreal Trudeau International Airport File No: 4.4 Owner: Craig Leask Project No: 144312087 LS Travel Retail North America Issued Date: March-18-13 370 King Street West, 6th Floor Toronto, On. M5V 1J9 Tel: (416) 863-6400 cc: No. of Pages: 12 Reference: CONTEMPLATED CHANGE NOTICE CCN/CO No: 01 The following items are Contemplated Changes to the Contract for this project, work is not to proceed unless authorized by a Change Directive or Change Order signed by the Owner. All materials and workmanship are to be in accordance with the Contract unless otherwise stated. Please submit an itemized quotation for changes to the Contract Price and Contract Time, within 5 Days of the date above. Title: T2626 Relay Domestic Reason: Changes to IFC drawings - requested by ADM A000 COVER SHEET - Revise drawing list A101 PARTION PLAN WALL SCHEDULE DOOR SCHEDULE - Add Frame Types see A101 - Revise door D2661-2 Height from 2100 to 1552 - Revise door D2661-2 Frame Type to Type 2 - Four sided A104 INTERIOR FINISH LIST - Revise Floor Transition TS-1 - Revise Wall Finishes WT-1 A200 REFLECTED CEILING PLAN - Delete wood ceiling at entrance around column - see A200 - Add Light Type 'H' and reposition spacing A201 CEILING DETAILS
Transcript

Stantec Architecture Ltd. 1100 - 111 Dunsmuir Street Vancouver BC V6B 6A3 Tel: (604) 696-8000 Fax: (604) 696-8100

Project: Relay T2626 Montreal Trudeau International Airport File No: 4.4

Owner: Craig Leask Project No: 144312087

LS Travel Retail North America Issued Date: March-18-13

370 King Street West, 6th Floor

Toronto, On. M5V 1J9

Tel: (416) 863-6400

cc: No. of Pages: 12

Reference:

CONTEMPLATED CHANGE NOTICE CCN/CO No: 01 The following items are Contemplated Changes to the Contract for this project, work is not to proceed unless authorized by a Change Directive

or Change Order signed by the Owner. All materials and workmanship are to be in accordance with the Contract unless otherwise stated. Please

submit an itemized quotation for changes to the Contract Price and Contract Time, within 5 Days of the date above.

Title: T2626 Relay Domestic

Reason: Changes to IFC drawings - requested by ADM

A000 COVER SHEET

- Revise drawing list

A101 PARTION PLAN WALL SCHEDULE DOOR SCHEDULE

- Add Frame Types see A101

- Revise door D2661-2 Height from 2100 to 1552

- Revise door D2661-2 Frame Type to Type 2 - Four sided

A104 INTERIOR FINISH LIST

- Revise Floor Transition TS-1

- Revise Wall Finishes WT-1

A200 REFLECTED CEILING PLAN

- Delete wood ceiling at entrance around column - see A200

- Add Light Type 'H' and reposition spacing

A201 CEILING DETAILS

- Revise 1 Wood Ceiling Layout - delete wood ceiling as shown

A300 STOREFRONT ELEVATION

- Elevation 2 - Delete wood ceiling

- Elevation 3 - Revise Door height and Door frame

A301 SECTIONS

- Section 1 - Delete wood ceiling

A303 DETAILS

- Add Details for Sign Box

A400 INTERIOR ELEVATION

- Interior Elevation 3 - Delete wood ceiling

Attachments:

REV A A000 COVER SHEEET

REV A A101 PARTITION PLAN WALL SCHEDULE DOOR SCHEDULE

REV A A104 INTERIOR FINISH LIST

REV A A200 REFLECTED CEILING PLAN

REV A A201 CEILING DETAILS

REV A A300 STOREFRONT ELEVATION

REV A A301 SECTIONS

REV A A303 DETAILS

REV A A400 INTERIOR ELEVATION

Stantec Architecture Ltd.

Charles Ivory, LEED® AP Senior Architectural Technologist Ph: (604) 696-8021

Cell: (604) 364-2899 Fx: (604) 696-8100 [email protected]

AREA = 116 meters sq.

1253.1 sq. ft.

PEART BERTRAND KOCH, ARCHITECTES

A000

COVER SHEET

CONSULTANTS:

PROJECT No. 1443 - 12087

RETAIL UNIT: T2626

A PROJECT FOR

RELAY

UNIT # T2626

DOMESTIC TERMINAL

MONTREAL TRUDEAU INTERNATIONAL AIRPORT

DRAWING LIST:

ARCHITECTURAL:

COVER SHEET A000

RESPONSIBILITY SCHEDULE A001

DEMOLITION PLAN A100

PARTITION PLAN A101

MERCHANDISING PLAN A102

FLOOR FINISH PLAN A103

INTERIOR FINISHES LIST A104

REFLECTED CEILING PLAN A200

CEILING DETAILS A201

STOREFRONT ELEVATION A300

SECTIONS A301

DETAILS A302

DETAILS A303

INTERIOR ELEVATIONS A400

FIXTURE DETAILS A500

FIXTURE DETAILS A501

CASHWRAP PLAN, ELEVATIONS AND SECTIONS A510

SPECIFICATIONS A600

SPECIFICATIONS A601

SPECIFICATIONS A602

SPECIFICATIONS A603

SPECIFICATIONS A604

MECHANICAL:

MÉCANIQUE, EXISTANT ET DÉMANTÉLEMENT M-1

MÉCANIQUE, CONSTRUCTION M-2

CLIMATISATION, NIVEAU 1 M-3

CLIMATISATION, NIVEAU 2 M-4

MÉCANIQUE, DEVIS M-5

ELECTRICAL:

DEVIS E-01

LEGENDE E-02

SCHÉMAS, CALCULS ET CÉDULES DE PANNEAUX E-03

AGENCEMENTS DEMOLITION E-04

AGENCEMENTS PLANCHER PROPOSE E-05-A

AGENCEMENTS PLAFOND PROPOSE E-05-B

TELECOM:

DEVIS T-01

AGENCEMENTS DEMOLITION T-02

AGENCEMENTS PROPOSE T-03

CLIENT / TENANT

LS TRAVEL RETAIL

NORTH AMERICA

370 KING STREET, 6TH FLOOR

TORONTO, ONTARIO, M5V 1J9

Telephone: (416) 863 - 6400

Contact: Craig Leask

1100 - 111 DUNSMUIR STREET

VANCOUVER, BC, V6B 6A3

Telephone: (604) 696 - 8000

Contact:: Douglas Stimson

FABRIQ

286 SAINTE-CATHERINE OUEST, SUITE 300

MONTREAL, QUEBEC, H2X 2A1

Telephone: (514) 934-1500

Contact: Jean-Christian Koch

STANTEC

ARCHITECTURE LTD.

AIRPORT /

LANDLORD

INTERIOR DESIGN ARCHITECT MECHANICAL/ELECTRICAL/

TELECOM

CONCEPTION ÉLECTRIQUE GÉNÉRALE

(NEQ 2263760987)

4545 GIROUARD, SUITE 107

MONTREAL, QUEBEC, H2A 0A1

Telephone: (514) 962-5786

Contact: Pascal Painchaud

AÉROPORTS DE MONTRÉAL

800 PLACE LEIGH-CAPREOL, SUITE 100

DORVAL, QUEBEC, H4Y 0A5

Telephone: (514) 633-3480

Contact: Mirela Rusu

RELAY

UNIT T2626

LOCATION PLAN

T

U

U.5

2827 29

Scale: 1:50

PARTITION PLAN

34

33

+/-

27

74

+/-

80

0+

/-

685 5601 3834

622+/-

7107+/-

26

46

+/-

24

47

42

53

34

68

NE

W C

ON

VE

NIE

NC

E S

HE

LF

SEISMIC RESTRAINT NOTE

EXISTING AIRPORT DEMISING WALL,

FIRE RATING AND INTEGRITY TO BE

MAINTAINED

16mm GWB, ONE SIDE (EXTEND GWB

150mm ABOVE CEILING)

92mm METAL STUDS @ 400mm O.C.

16mm TYPE 'X' GWB, BOTH SIDES (EXTEND

GWB TO U/S OF STRUCTURE)

92mm METAL STUDS @ 400mm O.C.

WALL SCHEDULE

16mm TYPE 'X' GWB, BOTH SIDES (EXTEND

GWB 150mm ABOVE CEILING)

92mm METAL STUDS @ 400mm O.C.

1. LEASE LINE

2. LINE OF SECURITY GRILLE

3. REFER TO ELECTRICAL DRAWINGS TO CONFIRM LOCATION OF NEW ELECTRICAL

PANEL

4. NEW AND REUSED WALL PANELS TO MATCH EXISTING. FINISH TO AS NEW CONDITION

5. LINE OF TRANSITION BETWEEN EXISTING AIRPORT FLOORING FINISHES. EXTENT

BEYOND TO REMAIN. REFER TO FLOOR FINISH PLAN A103 FOR EXTENT OF NEW

FLOORING.

6. EXISTING AIRPORT RESILIENT FLOORING TO REMAIN WHERE INDICATED ON A103

7. EXISTING AIRPORT CROSS BRACING TO REMAIN

ALL RETAIL SHELVING, DISPLAY AND MILLWORK UNITS GREATER THAN 900mm HIGH TO BE

SEISMICALLY RESTRAINED FOR FORCES DESIGNED IN ACCORDANCE THE NBCC 2010, AS

PER THE REQUIREMENTS OF PART IV . UNITS ADJACENT TO STUD WALLS TO BE

ATTACHED TO STUD WALLS USING A MINIMUM OF TWO 6mm - #14 SCREWS PER STUD AT

TOP OF EACH UNIT AND TWO 9.5mm HILTI KWIK BOLTS AT BASE OF ALL WALL SUPPORTED

UNITS. USING BLOCKING AND KWIK BOLTS AT THE BASE OF ALL FREE STANDING UNITS -

USE 13mm HILTI KWICK BOLT (EMBED 90mm) AT EACH CORNER OF FREE STANDING UNIT.

UNITS WITH HEIGHT LESS THAN 900mm THAT ARE NOT ANCHORED IN THE ABOVE

MANNER ARE TO HAVE WEIGHTED AND EXPANDED BASES TO PREVENT OVERTURNING.

BASES OF UNITS THAT ARE NOT ANCHORED TO HAVE A MINIMUM DIMENSION BETWEEN

SUPPORTS OF 450mm OR GREATER.

GENERAL CONSTRUCTION NOTES

KEY NOTES

6195

**

*

COORDINATE POSITION

OF CLERESTORY WITH

MILLWORK DIMENSIONS

*

*

TO

S

UIT

C

OO

LE

R

IN

ST

AL

LA

TIO

N

68

4

*

*

NEW GLASS

SEPARATION

812

FLUSH SINGLE

SOLID WOOD DOOR

PER DOOR

SCHEDULE

DOOR TYPES

PE

R D

OO

R S

CH

ED

UL

E

1

54

00

30

4

12

7

98

3

NEW GLASS

SEPARATION

MIRROR

SINGLE

1

FOUR SIDED

2

FRAME TYPES

PEART BERTRAND KOCH, ARCHITECTES

LOCATION MAP

A101

PARTITION PLAN

WALL SCHEDULE

DOOR SCHEDULE

AS NOTED

DOOR SCHEDULE

LOCATION DOOR FRAME HARDWARE REMARK

DOOR NO. ROOM NAME TYPE DIMENSION MAT

CORE /

GLAZING

FINISH TYPE MAT FINISH

HARDWARE

GROUP

D2626-1 BACK ROOM 1 915 x 2100 WD SC PT-1 1 WD PT-1 HEADING 1

D2626-2 BACK ROOM GLAZING ACCESS 1 762 x 1688 WD SC PT-5 2 MT PT-5 HEADING 2

D2626-E1 SALES AREA, GRILLE DOOR PL-3 EXISTING, REPAIR AS REQUIRED AND RE-FINISH

WITH PL-3

D2626-E2 SALES AREA, SECURITY GRILLE EXISTING, REPAIR AS REQUIRED TO AS NEW

CONDITION, ADD TO GRILLE AS REQUIRED

HARDWARE GROUPS

HEADING 1 HEADING 2

NO. HARDWARE MODEL FINISH NO. HARDWARE MODEL FINISH

2 PR. HINGES IVES 3CB1-114mm X 114mm x NRP 652 1 1/2-PR. HINGES IVES 3CB1-114mm X 114mm x NRP 652

1 EA. LOCK SET SCHLAGE L9080 626 1 EA. LOCK SET SCHLAGE L9080 626

1 EA. CLOSER LCN 4041-DEL-SPRING CUSH-TB

(MOUNT ON NON SALES SIDE)

689 1 EA. CLOSER LCN 4041-DEL-SPRING CUSH-TB

(MOUNT ON NON SALES SIDE)

689

1 EA. STOP IVES FS 446 - B26D 628 1 EA. STOP IVES FS 446 - B26D 628

1 EA. KICK PLATE IVES 8400-B4E-400mm X WIDTH LESS

38mm

630

1 EA. THRESHOLD PEMKO 171A-WIDTH

1 EA. PUSH PLATE IVES 8200-B26D-100mm x 450mm 630

1 EA. PULL PLATE IVES 8302-8-B26D-100mm X 450mm 630

CCN#01 - ADM REQUESTED CHANGES 13.03.18A

A

A104

INTERIOR FINISH LIST

PEART BERTRAND KOCH, ARCHITECTES

LOCATION MAP

Scale: 1:50

REFLECTED CEILING PLAN

T

U

U.5

2827 29

64

39

1. ALL CEILING HEIGHTS ARE FROM TOP OF FINISHED FLOOR TO UNDERSIDE OF FINISH CEILING OR LIGHT FIXTURE -

TYP. U.N.O.

2. THE TRADE CONTRACTOR SHALL SET ALL CEILING AND SOFFITS USING A LASER LEVEL TO ACHIEVE A CEILING THAT

IS PLUMB, LEVEL AND SQUARE TO ALL WALLS AND SOFFITS.

3. BRACING FOR SUSPENDED CEILING MUST BE PROVIDED BY CEILING CONTRACTOR. ANY ADDITIONAL HANGERS

AND SAFETY WIRES THAT MAY BE USED FOR LIGHT FIXTURES, DUCTWORK, SPEAKERS, ETC. TO BE THE

RESPONSIBILITY OF THE CEILING CONTRACTOR.

4. THE TRADE CONTRACTOR TO VERIFY W/LANDLORD, METHOD OF ATTACHMENT FOR ALL ITEMS ANCHORED TO, OR

SUSPENDED FROM EXISTING STEEL STRUCTURE.

5. ARCHITECTURAL DWGS DETERMINE THE LOCATION OF LUMINAIRES & SUPERSEDE ALL OTHERS, TYP. U.N.O. -

REFER TO ELECTRICAL DRAWINGS FOR EXACT FIXTURE TYPE & QUANTITIES PROVIDED.

6. REFER TO MECHANICAL DRAWINGS FOR EXPOSED SUSPENDED MECHANICAL DUCTWORK DISTRIBUTION SYSTEM.

7. PROVIDE ADEQUATE CLEARANCES FOR FIXTURES, DUCTS, CEILINGS AND RELATED PERTINENT ITEMS NECESSARY

TO MAINTAIN SPECIFIC HEIGHTS ABOVE FINISH FLOOR.

8. THE TRADE CONTRACTOR TO PROVIDE NECESSARY BLOCKING AND BRACING FOR FIXTURE INSTALLATION AND ALL

ELECTRICAL COMPONENTS TO COMPLETE THE FINAL INSTALLATION OF ALL FIXTURE - COORDINATE WITH FIXTURE

SUPPLIER.

9. DIMENSIONS ARE FROM FACE OF GWB TYP, U.N.O.

10. COORDINATE ADDITIONAL CEILING ACCESS DOORS W/ PROJECT MANAGER AND AS REQUESTED BY LANDLORD TO

MAINTAIN ACCESS TO LANDLORD EQUIPMENT.

11. ALL RIGID CONDUIT AND JUNCTION BOXES TO BE RUN TIGHT TO DECK IN A CLEAN AND ORDERLY FASHION.

12. ALL LIGHTING FIXTURE CALLED FOR TO BE REUSED MUST BE RE-LAMPED AS PART OF THE SCOPE OF WORK.

13. ALL ACCESS DOORS, DIFFUSERS, VENTS, RETURNS, ETC MUST BE PAINTED TO MATCH ADJACENT CEILING FINISH -

TYP.

1. LEASE LINE.

2. LINE OF SECURITY GRILLE.

3. INTERNALLY ILLUMINATED SIGNAGE BY SIGNAGE CONTRACTOR.

NOTES:

1. INSTALLATION OF LIGHTING FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS.

2. LAMPS SHALL BE AS SPECIFIED ABOVE - NO EXCEPTIONS.

3. CONTACT JOHN QUEEN AT 'QLCS' FOR PURCHASE OF LIGHTING FIXTURES AND LAMPS LISTED ABOVE. PHONE: 1-423-648-2039; FAX: 1-423-894-5172

4. LIGHTING DISTRIBUTOR TO PROVIDE ADDITIONAL LAMPS FOR FUTURE USE. COORDINATE QUANTITY WITH TENANT REP.

5. ELECTRICAL CONTRACTOR TO PROVIDE IDENTIFICATION NAMEPLATE ON THE ELECTRICAL SERVICE BREAKERS OF THE REMOTE ELECTRICAL PANEL. EACH NAMEPLATE SHALL BE 3 mm THICK

BLACK PLASTIC ETCHED IN A CONTRASTING COLOR WITH THE TENANT'S NAME. EACH PLATE SHALL BE PERMANENTLY AFFIXED TO THE DISTRIBUTION PANEL.

KEY NOTES

GENERAL CEILING NOTES

LIGHTING LEGEND

TYPE MFGR. CATALOG NUMBER DESCRIPTION LAMP TYPE REMARKS

A REGGIANA "ENVICS" REG39420RG132WW10 + REG36063 SURFACE MOUNTED 120V TRACK LIGHTING WITH DECORATIVE LOW

VOLTAGE ADJ. TRACK HEADS

32 W LED PROVIDE COMPLETE WITH ALL CONECTORS

AND END CAPS 120V

B CON-TECH P31AF-WW 2" RECESSED ADJUSTABLE LED PUCK LIGHT WITH 3000K LED, FLOOD

TYPE OPTICS AND 700mA DRIVER. (120V)

5 W LED

C JUNO SD6-1130-SAF2-825 6" VERTICAL RECESSED LED DOWNLIGHT WITH LOW IRIDESCENT HAZE

REFLECTOR, WHITE TRIM AND ELECTRONIC BALLAST (120V)

LED

D PHILIPS PHILIPS eW COVE QLX POWERCORE HIGH OUTPUT LINEAR COVE LIGHT, 305MM

LX 25MM H

LED

G XAL LIGHTING N661-123-00380-XXXX-X-X0 RECESSED TRIMMED ROUND FIXTURE WITH MILLED LAY IN LENS,

WHITE POWDER COATED ALUMINUM HOUSING.

T5

H LIGHTOLIER PB2T4 CALCULITE PROSPEC LINEAR DOWNLIGHT, BLACK HOUSING, T4.5 METAL

HALIDE

TRIM TO BE PAINTED PT-2, SEE FINISHES

LIST A/600

EM2 NAVILITE N3XXHO SELF CONTAINED ADJUSTABLE DESIGNER THERMOPLASTIC

EMERGENCY LIGHT WITH 5W MR16 LAMPS, MAINTENANCE FREE AND

6V SEALED LEAD CALCIUM BATTERY. VERIFY COLOR WITH ARCHITECT.

5W MR16

REL1 EXISTING 2P-3GAX-3BX40-ALC45-120-EB81 2' X 2' RECESSED METALUX FLUORESCENT 3 LAMP FIXTURE FOR 2'X 2'

T-BAR CEILING. PARABOLIC LENS 120V ELECTRONIC BALLAST, 3 20W

BIAX LAMPS

20 W BIAX EXISTING DROP IN FLUORESCENT TO BE

RELOCATED IN T2626A STORAGE ROOM

A

A

A

A

A

G

C

A

A

G

REL1

A

D

LED STRIPLIGHT

A

30

4

13

71

13

00

10

96

13

00

13

71

570

37

0

608

TYP

C

C

CC

C

C

C C

C

C

REL1

REL1

REL1

REL1

REL1

D

DD

DD

EQ. EQ. EQ.

565

606

68

HHHH

EQ. EQ.

H

PEART BERTRAND KOCH, ARCHITECTES

LOCATION MAP

A200

REFLECTED CEILING PLAN

AS NOTED

CCN#01 - ADM REQUESTED CHANGES 13.03.18A

A

Scale: 1:25

WOOD CEILING LAYOUT

Scale: 1:5

WOOD CEILING

Scale: 1:5

WOOD CEILING

Scale: 1:5

LIGHT IN WOOD CEILING

Scale: 1:5

WOOD CEILING

Scale: 1:5

LIGHTING SOFFIT

Scale: 1:5

MDF EYEBROW

Scale: 1:5

DETAIL

Scale: 1:5

MDF SOFFIT

PEART BERTRAND KOCH, ARCHITECTES

LOCATION MAP

A201 A

Scale: 1:25

STOREFRONT ELEVATION - WEST

TUU.5

368

30

51

82

9

90

8

10

70

19

86

Scale: 1:25

STOREFRONT ELEVATION - SOUTH

2827

21

34

901

30

5

30

5

30

5

19

95

28 27

Scale: 1:25

STOREFRONT ELEVATION - NORTH

29

PEART BERTRAND KOCH, ARCHITECTES

LOCATION MAP

A300

STOREFRONT ELEVATION

AS NOTED

CCN#01 - ADM REQUESTED CHANGES 13.03.18A

A

Scale: 1:10

SECTION

CONVENIENCE

SHELF

14 GA. STAINLESS

STEEL BASE ON

19mm PLYWOOD

WALL TILES

ON MDF TO

MATCH 19mm

WOOD VENEER

WALL NEXT

EXISTING BASE

BLDG. CEILING

ELEV. VARIES

GWB SOFFIT REFER

TO SHEET A200

ACT CEILING REFER

TO SHEET A200

HOLDROOMRELAY

Scale: 1:10

SECTION

GLAZING - SILL

TRACK, FRY

REGLET

EXISTING BASE

BLDG. CEILING

ELEV. VARIES

HOLDROOMRELAY

14 GA. STAINLESS

STEEL BASE ON

19mm PLYWOOD

WOOD VENEER

ON 19mm MDF

GLASS W/

VERT. CAULK

JOINTS

MDF SOFFIT

REFER TO SHEET

A200

ACT CEILING SEE A200

CONVENIENCE

SHELF

Scale: 1:10

SECTION

NEW WOOD

VENEER PANELS

TO MATCH

EXISTING, REUSE

EXISTING FULL

HEIGHT PANELS

WHERE POSSIBLE

EXISTING BASE

BLDG. UPSTAND

EXISTING BASE

BLDG. GWB

BULKHEAD

GLASS W/

VERT. CAULK

JOINTS

U.5

A301

SECTIONS

AS NOTED

PEART BERTRAND KOCH, ARCHITECTES

LOCATION MAP

CCN#01 - ADM REQUESTED CHANGES 13.03.18A

A

Scale: 1:25

INTERIOR ELEVATION

100

Scale: 1:25

INTERIOR ELEVATION

23

57

43

8

10

3

22

03

+/- T

OP

O

F M

IL

LW

OR

K U

NIT

S

15

2

1. PAINT AND WALLCOVERING TO EXTEND 10" BELOW TOP OF MILLWORK UNITS.

KEY NOTES

A400

INTERIOR ELEVATION

AS NOTED

PEART BERTRAND KOCH, ARCHITECTES

LOCATION MAP

CCN#01 - ADM REQUESTED CHANGES 13.03.18A

A


Recommended