ContentsEye/Face Washes ................................... 3Eyewashes ............................................... 3Swing-Away Eyewashes ..................... 4Eyewash/Drench Hose Units ............ 4Emergency Showers ............................ 4Safety Stations ....................................... 5
Portable Eyewashes ............................. 5Faucet Mounted Eyewashes ............. 6Barrier-Free Units .................................. 6Recessed Laboratory Units ............... 7Tempering Valves ................................. 7Freeze-Resistant Units ........................ 8
2 ETL Listed 101496. Units have been tested
to and comply with ANSI Z358.1-2014.
Listed 8116. Units have been tested to and comply with
ANSI Z358.1-2014 and the Uniform Plumbing Code.
ANSI Z358.1 - 2014 Highlights
location Install safety station within 10 seconds (approximately 55 feet) of hazard, on the same level as hazard and with unobstructed travel path. (Section 7.4.2; B5)
identification Identify safety station with highly visible sign. Area around safety station shall be well-lit. (Section 7.4.3)
water temperature Water delivered by safety station shall be tepid (60-100ºF). (Section 7.4.5; B6)
training Instruct all employees in the location and proper use of safety station. (Section 7.5.4)
maintenance/inspection Activate safety station at least weekly. (Section 7.5.2; B7) Inspect annually for compliance with standard. (Section 7.5.5)
ANSI Highlights This checklist is a summary of the provisions of ANSI Z358.1-2014 relating to eye or eye/face wash and shower combination stations. Please refer to the standard for a complete listing of these provisions.
All Guardian safety stations are third-party certified to meet or exceed the provisions of ANSI Z358.1-2014.
Connect unit to water supply capable of delivering required flow when all components are operated simultaneously. (Section 4.5.5, 7.4.4)
"Hands-free" stay-open valve activates in one second or less. (Section 4.2)
Height of water column shall be between 82" (208.3 cm) and 96" (243.8 cm) above floor. (Section 4.1.3, 4.5.4)
Shower shall provide 20 gallons (75.7 liters) of water per minute for 15 minutes. (Section 4.1.2, 4.5.5)
Easily located, accessible actuator no higher than 69" (173.3 cm) above floor. (Section 4.2)
At 60" (152.4 cm) above floor, the water pattern must be at least 20" (50.8 cm) in diameter. (Section 4.1.4)
Center of water pattern shall be at least 16" (40.6 cm) from any obstructions. (Section 4.1.4, 4.5.4)
Fluid flow pattern shall be positioned between 33" (83.8 cm) and 53" (134.6 cm) from the floor. (Section 5.4.4, 6.4.4)
Protect outlet heads from airborne contaminants. Covers shall be removed by water flow. (Section 5.1.3, 6.1.3)
Valve actuator shall be easy to locate and readily accessible to user. (Section 5.2, 6.2)
"Hands-free" stay-open valve activates in one second or less. (Section 5.2, 6.1.4, 6.2)
Unit must deliver at least 3.0 GPM (11.4 liters) (for eye/face wash) or 0.4 GPM (1.5 liters) (for eyewash) for 15 minutes. (Section 5.1.6, 6.1.6, 6.4.5)
Facility Safety
3ETL Listed 101496. Units have been tested
to and comply with ANSI Z358.1-2014.
Listed 8116. Units have been tested to and comply with
ANSI Z358.1-2014 and the Uniform Plumbing Code.
Eyewash, Wall Mounted, SS Bowl with CoverNo. 2LVH7
Application: Spray heads deliver water to rinse eyes.Spray Head Assembly: Two GS-Plus™ spray heads with ‘flip top’ dust covers, internal flow control, and filter to remove impurities from water flow.Valve: 1/2" IPS chrome plated brass stay-open ball valve. US-made with chrome plated brass ball and Teflon® seals.Bowl: 11-1/2" diameter stainless steel (SS) or ABS plastic.
Mounting: Wall or floor (pedestal) mounted. Heavy duty cast aluminum wall bracket or floor flange with corrosion resistant powder coated finish.Supply: 1/2" NPT female inlet.Waste: 1-1/4" NPT female outlet.Sign: ANSI-compliant identification sign.Quality Assurance: Units assembled and water tested prior to shipment.
Eyewashes
DESCRIPTION MFR. MODEL ITEM NO.
Eyewash, Wall Mounted, SS Bowl G1814 2LVH6
Eyewash, Wall Mounted, SS Bowl with Cover G1814BC 2LVH7
Eyewash, Wall Mounted, Plastic Bowl G1814P 2LVH5
Eyewash, Pedestal Mounted, SS Bowl G1825 2LVJ1
Eyewash, Pedestal Mounted, SS Bowl with Cover G1825BC 2LVJ2
Eyewash Pedestal Mounted, Plastic Bowl G1825P 2LVH9
Eyewash, Wall Mounted, All-SS G1891 2LVH8
Eyewash, Pedestal Mounted, SS BowlNo. 2LVJ1
Eye/Face WashesApplication: Spray heads deliver water to rinse eyes and face.Spray Head Assembly: Two FS-Plus™ spray heads with ‘flip top’ dust covers, internal flow control, and filter to remove impurities from water flow.Valve: 1/2" IPS chrome plated brass stay-open ball valve. US-made with chrome plated brass ball and Teflon® seals.Bowl: 11-1/2" diameter stainless steel (SS) or ABS plastic.
DESCRIPTION MFR. MODEL ITEM NO.
Eye/Face Wash, Wall Mounted, SS Bowl G1750 2LVJ4
Eye/Face Wash, Wall Mounted, SS Bowl with Cover G1750BC 2LVJ5
Eye/Face Wash, Wall Mounted, Plastic Bowl G1750P 2LVJ3
Eye/Face Wash, Pedestal Mounted, SS Bowl G1760 2LVJ7
Eye/Face Wash, Pedestal Mounted, SS Bowl with Cover G1760BC 2LVJ8
Eye/Face Wash, Pedestal Mounted, Plastic Bowl G1760P 2LVJ6
Eye/Face Wash, Pedestal Mounted,SS BowlNo. 2LVJ7
Eye/Face Wash, Wall Mounted, SS BowlNo. 2LVJ4
Eye/Face Wash, Wall Mounted, SS Bowl with CoverNo. 2LVJ5
Eyewash, Wall Mounted, Plastic BowlNo. 2LVH5
Mounting: Wall or floor (pedestal) mounted. Heavy duty cast aluminum wall bracket or floor flange with corrosion resistant powder coated finish.Supply: 1/2" NPT female inlet.Waste: 1-1/4" NPT female outlet.Sign: ANSI-compliant identification sign.Quality Assurance: Units assembled and water tested prior to shipment.
Facility Safety
4 ETL Listed 101496. Units have been tested
to and comply with ANSI Z358.1-2014.
Listed 8116. Units have been tested to and comply with
ANSI Z358.1-2014 and the Uniform Plumbing Code.
Swing-Away Eyewashes
DESCRIPTION MFR. MODEL ITEM NO.
Eyewash, Deck Mounted, AutoFlow™, Right Hand G1805 2LVJ9
Eyewash, Deck Mounted, AutoFlow™, Left Hand G1805LH 2LVK1
Eyewash, Deck Mounted, Flag Handle, Right Hand G1806 2LVK2
Eyewash, Deck Mounted, Flag Handle, Left Hand G1806LH 2LVK3
Eyewash, Sink Mounted, AutoFlow™ G1849 2LVK4 Eyewash, Deck Mounted, AutoFlow™ No. 2LVJ9
Eyewash/Drench Hose UnitsApplication: Dual purpose eyewash/drench hose units meet ANSI Z358.1-2014 and mount for hands-free fixed eyewash or may be removed to rinse eyes, face, or body. Drench hose units supplement ANSI compliant eyewash and shower stations. Spray Head Assembly: Dual purpose units contain two GS-Plus™ spray heads. Drench Hose units contain one FS-Plus™ spray head. All spray heads include ‘flip top’ dust covers, internal flow control, and filter to remove impurities from water flow.
Valve: Forged brass squeeze valve activated by stainless steel lever handle. Valve has replaceable stainless steel seat for durability. Locking clip engages when handle is depressed for ‘hands free’ operation. Valve remains open until locking clip is released.Hose: 8’ reinforced PVC hose with 300 PSI maximum working pressure. G5046 includes 12’ reinforced nylon hose for extra reach with 180 PSI maximum working pressure.
Mounting: Countertop/deck flange mount or wall mount with bracket and spring clips.Supply: 3/8" NPT male swivel-type inlet.Sign: ANSI-compliant identification sign.Quality assurance: Assembled and water tested prior to shipment.
DESCRIPTION MFR. MODEL ITEM NO.
Eyewash/Drench Hose Dual Purpose Unit, Wall Mounted G5026 2LVK6
Eyewash/Drench Hose Dual Purpose Unit, Deck Mounted G5022 2LVK5
Drench Hose Unit, Wall Mounted G5025 2LVK9
Drench Hose Unit, Deck Mounted G5020 2LVK8
Eyewash/Drench Hose Dual Purpose Unit, Wall Mounted, 12' Hose G5046 2LVK7
Backflow Preventer L108 2LV1
Drench Hose Unit, Deck Mounted
No. 2LVK8
Eyewash/Drench Hose Unit, Wall MountedNo. 2LVK6
Application: Spray heads swing to operational position to activate water flow. AutoFlow™ units activate water flow immediately as assembly swings over sink to operational position. Flag Handle units must be depressed to activate water flow. Units remain activated until spray heads return to original position.
Spray Head Assembly: Two GS-Plus™ spray heads with ‘flip top’ dust covers, internal flow control, and filter to remove impurities from water flow.Valve: 1/2" IPS plug-type with Teflon® coated O-ring seals.Strainer: In-line debris protection for valve and spray heads.
Mounting: Valve installed in Type 316 Stainless steel housing. Mountable on right or left side of sink.Supply: 1/2" NPT male inlet.Sign: ANSI-compliant identification sign.Quality Assurance: Assembled and water tested prior to shipment.
Emergency ShowersApplication: Wash away contaminants quickly and completely. Shower Head: 10" diameter stainless steel (SS) or ABS plastic.Valve: 1" IPS chrome plated brass or stainless
steel (All-SS). US-made with Teflon® seals. Includes stainless steel actuating arm and 29" stainless steel pull rod.Pipe & Fittings: 1" IPS galvanized or stainless steel (All-SS).
Mounting: Horizontal or Vertical mount.Supply: 1" NPT female inlet.Sign: ANSI-compliant identification sign.
Horizontal Emergency Shower
No. 2LVG8
DESCRIPTION MFR. MODEL ITEM NO.
Emergency Shower, Vertically Mounted G1635 2LVH2
Emergency Shower, Vertically Mounted, SS Head G1635SSH 2LVH3
Emergency Shower, Horizontally Mounted G1643 2LVG8
Emergency Shower, Horizontally Mounted, SS Head G1643SSH 2LVG9
Emergency Shower, Horizontally Mounted, All-SS G1691 2LVH1
Emergency Shower, Vertically Mounted, All-SS G1692 2LVH4
Vertical Emergency
Shower, All-SSNo. 2LVH4
Eyewash, Deck Mounted, Flag Handle No. 2LVK2
Facility Safety
5ETL Listed 101496. Units have been tested
to and comply with ANSI Z358.1-2014.
Listed 8116. Units have been tested to and comply with
ANSI Z358.1-2014 and the Uniform Plumbing Code.
Portable EyewashesApplication: Self-contained eyewash and/or drench hose units offer portable compliance. Ideal for low traffic areas, low hazard areas and where continuous supply of potable water is unavailable for plumbed units.Tank: Stainless steel pressurized tank or polyethylene tank. Built-in carrying handles included.Eyewash/Drench Hose Unit: Eyewash contains two GS-Plus™ spray heads and drench hose contains single GS-Plus™ spray head. All spray heads contain flip top dust covers, internal flow control and filter.Portable Eyewash, Gravity Fed: Gravity-fed unit delivers water through dual spray heads. Durable polyethylene tank is wall mountable with included steel bracket.
Heated Units: Electric heated units prevent freezing in cold weather environments. Silicone heating pads (G1540HTR) or drum heater (G1562HTR) maintain internal water temperature. Operates in temperatures as low as -20˚F. Durable high visibility orange insulation jacket included. Supplied with 15 amp GFCI plug for ground fault protection.Operation: Fill tank with clean, potable water. Add bacteriostatic additive (supplied with unit) to protect against growth of bacteria, fungus, algae and acanthamoeba. Pressurize stainless steel tank to 80 PSI. Unit must be inspected weekly and water must be changed once every six months.Sign: ANSI-compliant identification sign.Quality Assurance: Units completely assembled and tested prior to shipment.
Portable Eyewash, Gravity-FedNo. 2LVL4
DESCRIPTION MFR. MODEL ITEM NO.
Portable Eyewash/Drench Hose Unit, 15 gallon G1562 9XD46
Portable Eyewash/Drench Hose Unit, 15 gallon with Heated Insulation Jacket
G1562HTR 38NJ18
Hand Cart for Portable Eyewash/Drench Hose Unit 200-013R 9XD48
Portable Eyewash, Gravity-Fed, 16 gallon G1540 2LVL4
Portable Eyewash, Gravity-Fed, 16 gallon with Heated Insulation Jacket G1540HTR 38NJ19
Bacteriostatic Additive, Replacement G1540BA 2LVL5
Safety StationsApplication: Combination eyewash and shower station rinses contaminants from eyes, face, and body.Shower Head: 10" diameter stainless steel (All-SS) or ABS plastic.Shower Valve: 1" IPS chrome plated brass stay-open ball valve or Type 316 stainless steel (All-SS). US-made with Teflon® seals. Includes stainless steel actuating arm and 29" stainless steel pull rod.Spray Head Assembly: Eyewash units contain two GS-Plus™ spray heads. Eye/face wash units contain two FS-Plus™ spray heads. All spray heads include ‘flip top’ dust covers, internal flow control, and filter to remove impurities from water flow.Eyewash Bowl: 11-1/2" diameter stainless steel (SS) or ABS plastic.
Eyewash Valve: 1/2" IPS chrome plated brass stay-open ball valve or Type 316 stainless steel (All-SS). US-made with Teflon® seals.Pipe and Fittings: Schedule 40 galvanized or stainless steel (All-SS). Includes orange polyethylene vertical piping covers for high visibility and corrosion resistance.Supply: 1-1/4" NPT female top or side inlet.Waste: 1-1/4" NPT female outlet can be positioned 8" or 20" above floor.Sign: ANSI-compliant identification sign.Quality Assurance: Valve and spray head assemblies are assembled and water tested prior to shipment.
Safety Station with Eyewash, SS BowlNo. 2LVA6
Safety Station with Eyewash, SS Bowl with CoverNo. 2LVA8
DESCRIPTION MFR. MODEL ITEM NO.
Safety Station with Eyewash, SS Bowl G1902 2LVA6
Safety Station with Eyewash, SS Bowl with Cover G1902BC 2LVA8
Safety Station with Eyewash, Plastic Bowl G1902P 2LVA4
Safety Station with Eye/Face Wash, SS Bowl G1950 2LVC5
Safety Station with Eye/Face Wash, SS Bowl with Cover G1950BC 2LVC9
Safety Station with Eye/Face Wash, Plastic Bowl G1950P 2LVC3
Safety Station with Eyewash, All-SS G1991 2LVC1
Safety Station with Eye/Face Wash, All-SS G1996 2LVD2
Treadle Assy. For Hand/Foot Eyewash Control AP050-010 2LVC7
Alarm for Safety Station AP275-200 2LVD4
Portable Eyewash/ Drench Hose UnitNo. 9XD46
Portable Eyewash/Drench Hose Unit with Heated JacketNo. 38NJ18
Facility Safety
6 ETL Listed 101496. Units have been tested
to and comply with ANSI Z358.1-2014.
Listed 8116. Units have been tested to and comply with
ANSI Z358.1-2014 and the Uniform Plumbing Code.
Barrier-Free Units
Application: ADA compliant eyewash equipment for handicapped accessibility. Complies with requirements for maximum height and reach, minimum knee clearance, and distance from obstructions.Spray Head Assembly: Eye/Face wash includes four GS-Plus™ spray heads with ‘flip-top’ dust covers, internal flow control and filter to remove impurities.Eye/Face Wash Valve: 1/2" IPS brass stay-open valve with flag handle for easy activation.Eye/Face Wash Bowl: 11-1/2" stainless steel.Shower Valve: 1" IPS stay-open ball valve. Includes stainless steel actuating arm and stainless steel pull rod.
DESCRIPTION MFR. MODEL ITEM NO.
Emergency Shower, Barrier-Free GBF1643 2LVL6
Eye/Face Wash, Barrier-Free GBF1724 2LVL7
Safety Station, Barrier-Free GBF1909 2LVL8
Safety Station, Barrier-Free, All-SS GBF1994 2LVL9
Treadle Assy. For Hand/Foot Eyewash Control AP050-010 2LVC7
Alarm for Safety Station AP275-200 2LVD4
Pipe Fitting: Galvanized (GBF1909) or stainless steel (GBF1994). Includes orange polyethylene vertical piping cover for high visibility and corrosion resistance.Supply: 1/2" NPT female inlet (GBF1724), 1" NPT female inlet (GBF1643) or 1-1/4" NPT female top and side inlet (GBF1909, GBF1994).Waste: 1-1/4" NPT female outlet for 1-1/2" OD chrome plated brass tailpiece (GBF1724), or 1-1/4" NPT female outlet (GBF1909, GBF1994).Sign: ANSI-compliant identification sign.Quality Assurance: Valve and eye/face wash assembly factory assembled and tested prior to shipment.
Faucet Mounted EyewashesApplication: Convert any faucet into an emergency eyewash station and maintain normal faucet operation. Install at any sink to provide unlimited supply of potable water near potential hazards.Outlet Heads: Deliver soft, aerated water flow. Adjustable heads angle toward user to offer full coverage and avoid splashing. Float-off dust covers protect outlet heads. Eyesafe™ spray heads mount 3" apart fit most faucets. Eyesafe-X™ spray heads with larger profile fit gooseneck sinks.Operation: Pull knob to engage brass valve and activate eyewash. Eyewash remains activated until knob is pushed back to original position.
Faucet Control Valve: Offers single motion eyewash activation. Leave faucet ‘on’ at preset temperature. Twist control valve for normal sink operation. Eyewash may be activated with pull-knob at anytime regardless of control valve position.Inlet: Body has 55/64"-27 female thread. Three common faucet adapters (15/16"-27, 13/16"-27, and 3/8" IPS) included.Outlet: Removable bottom aerator included.Quality Assurance: Units assembled and water tested prior to shipment.
DESCRIPTION MFR. MODEL ITEM NO.
Faucet Mounted Eyewash, EyeSafe™ spray head G1100 2LVE1
Faucet Mounted Eyewash, EyeSafe-X™ spray head G1101 2LVE3
Faucet Mounted Eyewash, EyeSafe™ spray head with Faucet Control Valve G1200 2LVE5
Faucet Mounted Eyewash, EyeSafe-X™ spray head with Faucet Control Valve G1201 2LVE7
Faucet Mounted EyewashNo. 2LVE1
Faucet Mounted Eyewashwith Control ValveNo. 2LVE7
Alarm for Safety Station (station sold separately)
No. 2LVD4Emergency Shower,
Barrier-FreeNo. 2LVL6
Safety Station, Barrier-FreeNo. 2LVL8
Eye/Face Wash, Barrier-FreeNo. 2LVL7
Facility Safety
7ETL Listed 101496. Units have been tested
to and comply with ANSI Z358.1-2014.
Listed 8116. Units have been tested to and comply with
ANSI Z358.1-2014 and the Uniform Plumbing Code.
Tempering ValvesApplication: Blend hot and cold water to deliver tepid water to emergency equipment.Tempering Control: Bimetallic thermostat senses incoming water temperatures and automatically blends water to 85˚F (29˚C). High temperature limit stop set to 90˚F (32˚C). Dial thermometer measures delivered water temperature. Note: Valve may need to be adjusted when installed based on incoming water temperature. Refer to "Installation instructions" for further information.Supply Pressure: 30 PSI minimum supply pressure required. Maximum supply pressure is 125 PSI.
DESCRIPTION MFR. MODEL ITEM NO.
Tempering Valve for Eyewash, 6 Gal. Capacity G3600LF 38NJ20
Tempering Valve for Eye/Face Wash, 34 Gal. Capacity G3700LF 38NJ21
Tempering Valve For Safety Station, 44 Gal. Capacity G3800LF 38NJ22
Fail Safe: During hot water supply malfunction, internal bypass delivers cold water to emergency unit. During cold water supply malfunction, valve closes to prevent scalding and will not deliver water.Mounting: Secures to wall or panel with included heavy duty mounting bracket.Quality Assurance: Assembled and water tested prior to shipment. Certified to meet low lead requirements of wetted surface area less than 0.25% lead by weight. Tempering Valve
for Safety StationNo. 38NJ22
Tempering Valve for EyewashNo. 38NJ20
Recessed Laboratory UnitsApplication: Recessed barrier-free eye/face wash and shower safety station with ceiling mounted exposed shower head and drain pan. Stainless steel cover for attractive appearance and protection when not in use. ADA Compliance: ADA compliant when installed at recommended minimum mounting heights.Shower Head: 10" diameter stainless steel.Shower Valve: 1" IPS brass stay-open ball valve with stainless steel ‘panic bar’ actuator.Cover/Drain Pan: 16 gauge stainless steel combination cover and drain pan. Pulling ‘Panic Bar’ handle opens cover and pulls spray head assembly to horizontal position to activate water flow. Waste water collects in drain pain during operation and returns into cabinet for drainage. Unit remains in operation until cover is returned to closed position. Daylight drain (GBF2152) offers cost effective installation with drainage out the front of unit.
DESCRIPTION MFR. MODEL ITEM NO.
Recessed Safety Station with Cover/Drain Pan GBF2150 3GUL6
Recessed Safety Station with Cover/Drain Pan, Daylight Drain
GBF2152 3GUL7
Recessed Emergency Shower GBF1670 3GUL9
Recessed Eye/Face Wash with Cover/Drain Pan GBF1735DP 3GUL8
Modesty Curtain for Recessed Laboratory Units AP250-065 3GUM2
Alarm for Recessed Laboratory Units AP280-230 3GUM1
Eye/Face Wash Spray Head Assembly: Two FS-Plus™ spray heads mounted on supply arms include adjustable flow control and filter to remove impurities.Eye/Face Wash Valve: 1/2" IPS brass rotating plug-type valve. Teflon® coated O-ring seals and in-line strainer protect valve from debris.Mounting: 16 gauge stainless steel cabinet with flanged rim for recessed wall mounting. Fits standard 3 5/8" deep walls.Pipe and Fitting: Stainless steel exposed pipe and escutcheon.Supply: 1" NPT female inlet (GBF2150, GBF2152) or 1/2" NPT female inlet (GBF1735DP).Waste: 2" NPT female outlet (GBF2150, GBF1735DP) or 1 1/2" OD tailpiece with stainless steel cover (GBF2152).Sign: ANSI-Compliant identification sign.Quality Assurance: Assembled and tested prior to shipment.
Recessed Safety Station with Drain Pan shown with Modesty Curtain and Alarm. No. 3GUL6, 3GUM2, 3GUM1
Facility Safety
ETL Listed 101496. Units have been tested
to and comply with ANSI Z358.1-2014.
Listed 8116. Units have been tested to and comply with
ANSI Z358.1-2014 and the Uniform Plumbing Code.
Freeze-Resistant UnitsApplication: Electric heat-traced stations prevent freezing even in extreme conditions. Thermostat regulated units are heated by self-limiting heat-tracing cable wrapped around internal pipe. Units are intended for cold weather use down to -20°F. See ‘Tempering Valves’ section to ensure tepid water compliance with ANSI Z358.1-2014.Heating Cable: Self-regulated with external termination guards. Thermostat activates when internal piping temperature falls below 75°F. FM, UL, and CSA approved for Class I, Division 2, Groups B, C, and D.Electrical System: Unit is fully wired at factory. Junction box and components rated for Class I, Division 2, Groups B, C, and D. Requires 120 VAC single phase power supply.Jacket/Insulation: UV-resistant orange ABS plastic with polyethylene foam insulation. Jacket sections secured with removable stainless steel screws for easy maintenance.
Remote Sensing and Audible Alarm: Remote sensing flow switch (GFR3101, GFR3107, GFR3111, GFR3117) allows monitoring of unit activation from remote location. Audible alarm horn and strobe light (GFR3107, GFR3117) signal unit activation.Shower Head: 10" diameter orange ABS plastic with 20 GPM flow control.Shower Valve: 1” IPS brass stay-open ball valve. US-made with brass ball and Teflon® seals. Includes stainless steel actuating arm and 29” stainless steel pull rod.Spray Head Assembly: Freeze-resistant with float-off dust covers and internal flow control.Eyewash Valve: 1/2" IPS brass three-way self-draining stay-open ball valve. US-made with brass ball and Teflon® seals. Includes 1/2" NPT port to drain water from spray heads after use.Pipe and Fittings: Schedule 40 galvanized steel.Supply: 1-1/4” NPT female top or bottom inlet.Sign: ANSI-compliant identification sign.Quality Assurance: Factory tested prior to shipment. Ships fully assembled and crated.
DESCRIPTION MFR. MODEL ITEM NO.
Heated Safety Station with Eyewash, Top Inlet GFR3100 38NJ12
Heated Safety Station with Eyewash, Top Inlet, Remote Sensing Flow Switch
GFR3101 38NJ16
Heated Safety Station with Eyewash, Top Inlet, Remote Sensing Flow Switch, Alarm Horn, Light
GFR3107 38NJ14
Heated Safety Station with Eyewash, Bottom Inlet GFR3110 38NJ13
Heated Safety Station with Eyewash, Bottom Inlet, Remote Sensing Flow Switch
GFR3111 38NJ17
Heated Safety Station with Eyewash, Bottom Inlet, Remote Sensing Flow Switch, Alarm Horn, Light
GFR3117 38NJ15
Heated Safety Station with Eyewash, Bottom Inlet
No. 38NJ13
Heated Safety Station with Eyewash, Top Inlet,
Remote Sensing Flow Switch, Alarm Horn, Light
No. 38NJ14
AVAILABLE THROUGH
For more information contact your Grainger Representative or visit Grainger.com®.
8SS7008