CONTENTS
High intelligent control system
High quality user experience
Optional Parts
High intelligence and reliable operation
High quality product lineup
High flexibility of installation and
maintenance
Fujithermar VRF Plus series inverter-driven multi-split central air conditioning adopts full DC
fan motors adopt variable speed motors, which can bring extraordinary user experience--high
high flexibility of installation and maintenance, and high intelligent control and management,
capacity is from 8HP to 54HP in 2HP increments, various models can serve the government
occasions better,which can improve the environmental quality and create a healthy life.
Full DC Inverter
02
Hig
h E
ffici
ency
Per
form
ance
Hig
h E
ffici
ency
Per
form
ance
Air conditioning is a big power consumer in our daily life. Authoritative statistics show that the energy
consumption of central air conditioning generally accounts for 40 % to 60% in the whole building
energy consumption, thus energy saving of air-conditioning has important social significance.
High efficiency high-pressure
chamber scroll compressors
high-pressure chamber scroll compressors with an interior oil separating
Outdoor units of Fujitherma VRF Plus series adopt large capacity high efficiency
section, which maintains most of lubricating oil in compressor by the use of
interior oil moist separator and oil-returning pipe design. Only much less oil
is discharged from compressor along with refrigerant, which avoids cooling
capacity decrease due to redundant oil in refrigeration cycle, further
Special scroll disc design
□
□
New type scroll
compressor
Inside chamber Pi=Ps
Outside chamber Po=Ps
Suction completed
Inside chamber Pi=Ps
suction completed
Outside chamber Po> Pi
condition from the
suction to 180°on the
way of compression
Suction losses decreased
Leakage losses decreased
Interior oil separation
mechanism
Asymmetric scroll disc
supply with high stability
low noise
DC variable speed motor
Fujitherma VRF Plus series inverter central air conditioner, all the compressors adopt DC variable speed compressors, and
all the fan motors adopt DC motors. The leading full-DC inverter control technology and a variety of intelligent
energy-saving technologies realize the optimal energy saving performance of VRF Plus series.
The compressor stator adopts centralized winding stator that can reduce coil height and copper loss;the compressor rotor adopts the latest
ncy
dramatically. By the use of DC motor, the performance is improved at around 20~80Hz where the operation time of the inverter compressor is
longest. Meanwhile, the rotor of compressor is divided into two parts to suppress electromagnetic interference(EMI) which achieves low noise.
Centralized winding stator DC motor rotor
� speed controls
� Unique magnetic noise of
DC compressor is removed
Optimized rotor
shape
Using Neodymium
Magnetic Materials
� Low height
� Low copper loss
�
The asymmetrical scroll structure of
the refrigerant gas leakage loss in the
process of suction and compression,
reliability.
Centralized DC motor
0 1200
2400
3600
4800
6000
7200
Distributed DC motorAC motor
R e v / m i n(rpm)
○
High Efficiency Performance
03
□ Precise Room Temperature Control □ Latest 180-degree sine wave DC
Inverter-Driven Technique
Industry-leading inverter controller is adopted in VRF Plus series , it is
the upgrade product of mainstream type IGBT inverter controller with
small volume and high precision, and it has internal multi-protection
controls (over voltage, under voltage, phase loss, phase error,
over-current, overheating, etc.), so the control accuracy and reliability of
the inverter are improved dramatically.
Time (h)
Load %
Conventional Inverter Control
The operating speed of DC motor in compressor can be adjusted
continuously and freely relating to the variability of system
capacity. This technique integrated auto-adaptive control
technique automatically adjusts capacity output according to
actual air conditioning load in order to achieve a smoother curve
of temperature fluctuation to satisfy higher requirements of
coziness.
DC Inverter-Driven Technique
180° Sine wave DC Inverter-Driven Technique
Time
180°Sine wave
180°
Electric current
Voltage
Traditional control method
TimeVoltage
Electric current
120°Rectangular wave
120°
30° 120° 60°
Time (h)
Load %
Fujitherma Precise Inverter Control
Air conditioning capacity outputIndoor load
Air conditioning capacity outputIndoor load
Outdoor unit fan motor adopts DC inverter-driven motor which
significantly. The outdoor unit fan can achieve stepless speed
regulation according to the ambient temperature changes.
Stepless fan speed regulation
technology
Streamlined air grille
◎ Stepless frequency conversion adjustment of the fan
◎ Fan Protection FunctionIn case that the external forces make outdoor unit fan rotate inversely , the fan will be stopped first when the air conditioner is started, and then the fan will rotate normally in accordance with procedures to protect the blades from damage.
An
ti-b
ack
win
d
Co
nve
nti
on
External forces make the fan
counter-rotating
External forces make the fan
counter-rotating
Instantaneous reverse rotation with sudden
increased torque may cause damage to the blades
Forward rotation with small
starting torque, protect fan blades
Stop the fan before start
the unit
Fan speed
High
Low 0
1050rpm
Stepless speed
regulation
Common speed
regulation
◎The stability of discharge pressure and suction pressure of the compressor is assured;◎The stability of the indoor unit flow (capacity) dynamic allocation is assured and the fluctuation is reduced;◎Quick response of control systems is improved, accordingly the stability, durability and reliability of units are assured.
04
New type efficient heat exchangerΦ7.0mm and new type fins, which reduces the air-flow resistance,
of frost on
Optimized refrigerant circuit design
Two-stage Supper-cooling Circulation
A sub-cooling section is designed in the heat exchanger of outdoor unit to realize the first stage supper-cooling. Furthermore,
is applied to achieve the second-stage supper-cooling. The total supper-cooling degree is up to 27℃.
○ The two-stage super-cooling cycle improves cooling capacity;
○ The pressure loss of the refrigerant flowing in the pipe is reduced
○ The Increased super-cooling degree promotes the stable operation
of the electronic expansion valve;
○ The increased super-cooling degree helps increase the total piping length.
□ Two-stage super-cooling cycle diagram □ Two-stage super-cooling pressure enthalpy diagram
Sub-cooler Heat exchanger super-cooling section
Cooling capacity
Gas
refrigerant
Gas
refrigerantLiquid
refrigerant
Liquid
refrigerant
Liquid
refrigerant
Liquid
refrigerant
Gas
refrigerant
Gas
refrigerant
Gas
refrigerant
Gas
refrigerant
Liquid
refrigerant
Ga
s p
ha
se
Gas-liquid
mixed phase
Liq
uid
ph
ase
Increase the proportion of liquid
refrigerant in the heat exchanger to
Gas refrigerantGas-liquid
mixed phaseLiquid refrigerant
Common refrigerant circuit Optimized refrigerant circuit
Wind direction Wind direction
Overlapping section
surface of fins
Overlapping section
surface of fins
Thick Thin
Previous fins The latest developed fins Hierarchical diagram of
hydrophilic aluminum foil
down flow speed of defrost water or condensate water and
improves the air conditioning performance.
Lubricating layer
Hydrophilic coating
Corrosion-resistant coating
Fin
copper tube
First stage of super-cooling
Second stage of super-cooling The increased cooling
capacity in super-cooling cycle
Ga
s p
ha
se
Gas-liquid
mixed phase
Liq
uid
ph
ase
05
Smart and precise unit capacity allocation
○ Central air conditioning system is working under partial load most of the time; VRF Plus series optimizes
condition.
In normal operation, the module combination is operated at full load + ultra-low load, which influences the service life of units and consumes more power.
Common product:d t
be lowest when each module unit is working at 40% - 75% partial load.
Fujitherma VRF Plus Series:
VS
tion is lowest.Take
20HP units (double module) as an example, when the units operate under 12HP load, the load distribution of each module: common product is 10HP (full
load) +2HP (ultra-low load); Fujitherma VRF Plus series is 6HP+6 HP (intermediate load).
Demand mode (Energy saving mode)
The intelligent demand mode can adjust the air conditioning operation automatically according to peak-valley requirements of
electricity. It achieves balance between the comfort and energy saving while meeting the power demand for daily work.
For mode settings, please contact your local service engineer. The output capacity of the unit at this moment is less than the rated value because
operating power is limited.
Morning Night
Daily running time
Setting Power
Po
we
r C
on
su
mp
tio
n
When the power consumption value exceeds
the set range, it will be restricted
Operating cost
Operating cost
Power Saving 20%
06
Hig
h In
telli
genc
e an
d R
elia
ble
Ope
ratio
nH
igh
Inte
llige
nce
and
Rel
iabl
e O
pera
tion
□“Preconceived” Control
Intelligent operation
and control
The system can be locked to the heating mode only or cooling
transitional season. For example, when this function starts, it can be locked to cooling mode only in summer or heating mode only in winter.
Fujitherma VRF Plus series innovatively applies a variety of intelligent technology and realizes a
series of intelligent operation from component selection to the unit operation. Comprehensive
intelligent control capacity ensures Hi quality of the system. Meanwhile, based on the high-end
technology support platform of Fujitherma inverter central air-conditioning, the operation of VRF Plus
Series is more reliable.
□ Operation mode control
□ Access Management
There are room cards and access management function settings,which can realize linkage control in Hotel Management System or Smart Home System,that is,the air conditioner will start working under the previous operation mode when the card is inserted, avoiding the waste running.
While the system is running,if there are some indoor units are set to
indoor units will give an alarm "operation restriction", the other units are in normal operation without stopping or alarm.
Heating mode only
in chilly winter
Cooling mode only
in hot summer
Operating limited
Heating
High intelligence and
reliable operation
07
□ VIP Service Control
The "VIP" mode is designed for the important rooms in the system, that is, giving priority to ensuring heating and cooling needs of VIP room under special power supply circumstances.
System can assign indoor unit addresses without manual setting automatically, it is suitable for the use of multiple indoor units of large system.
○It is a customized feature, the VIP Room is a room with capacity priority assurance; setting VIP service priority mode
under harsh working conditions.
□ Automatic addressing
□ Operating data, fault data displaying
□ Service Checker
channels and display the data. There are four 7-segment high brightness digital tubes to display the real-time fault parameters through adjusting the master PCB buttons of outdoor unit, it is very convenient for commissioning and maintenance
ON ON ON ON ON
Power supply
shortage
VIP RoomCapacity priority
assurance
□The operating data can be recorded automatically as power failure occurs. When the power supply is restored, the system can fulfill automatic start-up(Manual operation is also allowed), the previous operation mode can be renewed without being reset, which brings more intelligent and considerate service to users.
01
The system operates normally
02 03
system stops running
Restore to the previous state when
the power supply is recovered.
Service Checker is designed to quickly inspect the units operating status. Problems can be found out as early as possible, then solution can be taken accordingly.
08
□ Temperature sensing
There are multiple thermal probes in the system, which will make real-time detection and feedback on the outdoor temperature, indoor temperature and outlet air temperature etc,the system output is adjusted by the master controller.
Accurate self-diagnosis and self-control of system
pressure and temperature
□ 32-bit MCU and high-speed transmission bus
Adopting 32-bit MCU data processing, together with the high-speed transfer bus can make up to dozens of multitasking perfect signal processing of outdoor unit control, indoor unit control, temperature control, compressor frequency, fan motor speed and switches, etc.
maintain the operation stability.
32-bit Data processing MCU
□ Refrigerant flow control
Indoor units adopt microcomputer electric expansion valve with 2000-stage automatic adjustment function, which can make precise flow adjustment automatically according to the actual load of indoor units with more accurate temperature regulation and
2000-Stage Electric Expansion Valve
□ Fast, accurate pressure sensing technology
Combined with compressor frequency control, fan speed, electronic expansion valve opening degree, the pressure sensing technology puts the condensing pressure and evaporating pressure of system in the best condition, so as to ensure the unit more stable running, more timely protection and longer service life.
The system pressure is controlled by the use of precise high & low pressure sensors, which can collect the system pressure parameter in high frequency continuously,and the give real-time feedback of measurement results,realizing precise controls in the output through the master controller at first time.
Pressure Sensor
01
01 Compressor frequency control
02 Fan operation control
03 Electronic expansion valve opening degree control
02
03
Unique Design
outlet air temperature sensor
09
□ The first-stage oil separation
structure inside high-pressure chamber compressor, only a small amount of oil is brought out of the compressor.
□ The second-stage oil separation
A small amount of oil discharged from the compressor is separated by the second-stage oil separation through large-capacity, high
over 99%.
Multiple oil circuit protectionOil balance between outdoor units is realized through two-stage oil separation technology, double oil control technology, and oil balancing control, which ensures more secure and reliable operation of the system.
□ The first-stage oil-return control
The accumulator adopts porous oil return technology
the oil balance between the compressors within the module, but also plays a role in the oil balance between the modules. 23
1
4
Outdoor unit 1 Outdoor unit 2
Accumulator
Intelligent defrosting modeThe outdoor unit adopts outdoor temperature sensor and heat exchanger temperature sensor to make variable-parameter defrosting, accurately grasp the defrosting opportunity, and significantly reduce the amount of frost, only 1/3 of that under ordinary defrosting mode.Meanwhile together with unique bottom anti-frost design structure, “2 in 1” heat exchanger, it can ensure that there is no frost at the bottom of outdoor heat exchanger during winter heating. When defrosting, the mixture of ice and water left along the fins is heated fully to liquid and discharged through the bottom drain hole, so as to avoid accumulation of frost at the bottom leading to poor heating performance.
Bottom anti-frost design when heating
Common defrosting
Heating operation
Heating operation Heating operationHeating
operationHeating operation Heating operation
Heating operation Heating operation Heating operation Heating operation Heating operation
Little frost Still not much frost
Heating operation
Little frost Still not much frost
defrostingFujitherma optimal defrost mode
Common multi-split AC defrosting mode only refers to Time and Temperature parameter , besides these, Fujitherma adopts the pressure defrosting mode, which adopts the pressure sensor to get the pressure signal and completes the variable parameters defrosting operation through the Pressure, Temperature and Time parameter.
First-stage oil separation Second-stage oil separation
10
□ Oil balancing control between outdoor units
Through adjusting the relationship between the amount of discharge oil and return oil in the compressor, accumulator and the oil separator, it can realize automatic balance of lubricants between the various outdoor units without oil balance pipes, avoid fluctuations of system pressure and temperature caused by oil balance pipe mode, and simplify the construction and improve the operational stability and comfort of system.
Without oil balance piping in
outdoor unit, making the oil
return more stable, more
for installation.
Anti-snow Function
□ Rotational operation
By rotational operation technique, the running time of each outdoor unit module is balanced,the unit durability is improved,and the life of the air conditioning system is extended.
□ Dual backup operation
The backup operation function that prevents the system from coming to a complete stop can be fulfilled in two ways.1.as one compressor breaks down, the other compressor in the same outdoor units can be set to emergency operation mode(for 114kBtu/h upward models).2.As one of the outdoor units breaks down, the rest of outdoor units in the same refrigerant system can turn to operate urgently (For 154kBtu/h upward models).
In the event of bad weather like snowstorm, even if outdoor unit is not operating, the sensor for snow on outdoor PCB can still be shorted because of natural snowflake, then the outdoor fan motor starts rotating at full speed to prevent outdoor unit from being covered by snow.When air conditioning starts up, the fan motor will turn to normal speed.
Multiple operation mode, ensure long life and reliable operation
□ The second-stage oil-return operation
The system implements oil-return operation based on the compressor frequency and corresponding operation time, which avoids the oil retention in the indoor heat exchanger and outdoor heat exchanger when the system is running at low load for a long time, and avoids compressor failure due to lack of refrigeration oil. The oil-return operation time is only 60 seconds, after the oil-return control, it will automatically return to the previous operation state.
In winter under heating mode, the oil return operation is implemented without changing to the cooling,
Compressor
Frequency
Oil return
operation
High
Low
Time
This time
Next timeLast time
Rotational
operation
Liquid pipe
Gas pipe
Standby status
Running status
Fault Status
The first-stage backup The second-stage backup
○
○
Connector Outdoor Unit PCB
Anti-snow Function Graph
*This Function Needs Optional Accessory
Power Supply
Control Circuit
SS3:Snow sensor
SS3
X1
eWithout oil
balance pipe
11
High Quality User
Experience
Smart controllers, simple human-machine interactionFujitherma has a variety of controllers with smart and beautiful shape, flexible and easy to use. Users can experience a new sense of comfort and smart by making choice according to their personal needs.
□ Actively respond to RoHS directive
□ Use environment-friendly refrigerant R410A
RoHS is called [Reduction of the following six Hazardous Substances in Electrical and Electronic Equipment]. This directive prohibits the use of the following six hazardous substances in electrical and electronic equipment [lead, mercury, cadmium, hexavalent chromium, poly-brominated diphenyl ethers (PBDE) or (PBB)]. Fujitherma responds to European RoHS directive actively and carries out a series of procedures and interventions to control hazardous substances. This directive aims to protect human health and ensure recycling and disposal of waste electrical and electronic equipment to meet the environmental requirements.
refrigerant R410A , which is non-toxic to humans and will not damage the Earth's ozone layer, create a comfortable, clean living environment for you.
Advocate and practitioner of low-carbon living space
Substance
Lead
Cadmium
Hexavalent chrome
Mercury
PBB/PBDE
RoHS limit value
1000ppm
100ppm
1000ppm
1000ppm
1000ppm
Typical Test Method
Wet chemical treatment or X-ray fluorescence
Wet chemical treatment or X-ray fluorescence
Wet chemical treatment or X-ray fluorescence
Wet chemical treatment or X-ray fluorescence
GCMS, FTTR, or X-ray fluorescence
In order to make the relation between people and air, people and the environment more friendly and
natural, Fujitherma VRF Plus focuses on user experience in product design and improving the
environment - processing and control of air temperature, humidity, speed, cleanliness; moreover, G
series pay much attention to the customer's health - fresh air and quiet and customer’s convenience
in use.
Environment-friendly
Refrigerant
Hig
h Q
ualit
y U
ser E
xper
ienc
eH
igh
Qua
lity
Use
r Exp
erie
nce
12
□ Three-dimensional temperature sensing design
The refrigerant flow is regulated by supply air temperature sensor, return air temperature sensor, remote control temperature sensor set in the indoor unit, the air temperature is controlled within the optimum range, satisfying human comfort better by combining with microcomputer controlled high-precision electronic expansion valve of 2000 pulses; while meeting indoor temperature control accuracy of ±0.5℃.
Precise temperature control, comfortable air supply
□ 360°around air supply, more even temperature
Fujitherma 4-way cassette type indoor unit expands supply air flow to every corner of the interior space through 360 degrees all-around supply air and adjustment of the louver position, which forms all-around surround airflow, without dead angle for air supply and ensures the most comfortable space with more even indoor temperature.
□ Indoor unit noise control
Techniques and installation methods of reducing operating noise of indoor units are researched according to the using occasions, structural features, fan motor, fan blades and duct layout etc, which ensures to provide a most quiet and comfortable air-conditioning environment for the users.
Excellent mute design, achieve ideal quiet environment
□ Noise control of outdoor units
Adopt high quality scroll compressor —— Sophisticated manufacturing technology, with characteristics of little vibration and low noise.
Silence process of fan motor
——Select cast aluminum as manufacturing material of the fan motor. Motor bracket adopts non-resonant hanger structure to ensure stable electrical motor performance and reducing vibration noise.
Noise level of Slim Ceiling Ducted type AVE-07/09* at low speed.
Quiet libraryWhisperIn bedroom noise of 30dB (A)
Bustling streetIn operation
dB(A)70dB(A)30dB(A)20 dB(A)21 dB(A)40�
�
360°
13
□ Wide operating range
The system can run within a wide temperature range, the lowest heating operation can reach -23℃in winter.
□ Rapid cooling and heating
Through quick start technology of the compressor, the unit can achieve 100% output of heating capacity in a very short period of time, and meet the demand for air conditioning in the space quickly.
Quick start, quickly meet the needs of the space comfort
New type efficient axial fan
around the fan, uses special materials to absorb vibration and noise, which can significantly reduce "buzzing" sound.
Night Silence Mode——The outdoor unit has a unique Night Mode setting function, the Max.noise level in full load operation at night is 15dB(A) lower than that in normal operation in daytime, only 41dB (A) (take AVWT-76 for example).
New type blades
Optimizing axial
angle of the wind
Optimizing radial
angle of the wind
30 40 502010
-10 0-20
Heating operation range
Cooling operation range
-23℃ WB+19℃WB
+50℃DB
-5℃ DB
Environmental load change curve
Temperature change curve
Noise change curve
The maximum temperature
41dB(A)
8 hours 9 hours
Decline
15dB(A)
Need about 90 seconds to reach 100%
capacity output (Data of 48HP Model)
90 seconds
14
High Flexibility of Installation
and Maintenance
Small size, light weight, saving space in transportation
and installation
the elevator can be used to uplift the base unit(MAX.170kBtu/h) separately. Easy and flexible transportation and installation are further enhanced by adopting the lightweight and compact design of outdoor units
Transportation mode
VRF Plua series pay much attention to every detail in product design, taking full account of the
realities of engineering application. The installation flexibility of the product design is greatly
improved through a series of technical upgrading.
Elevator
Outside dimension of model 16HP
The door size of elevator car with a load of more than 630kg is 800mm×2100mm, the car depth is greater than 1250mm, a single module can be moved in, so it is easy to transport in high-rise buildings.
Note:The size of the elevator car is for reference only.
Transportation modeH
igh
Fle
xibi
lity
of In
stal
latio
n an
d M
aint
enan
ceH
igh
Fle
xibi
lity
of In
stal
latio
n an
d M
aint
enan
ce
15
method, aviation dynamic fluid simulation analysis and other advanced concepts; its air inlet angle and outlet angle are optimized; together with unique horn air vent design, the external static pressure of outdoor unit is higher, which can better exhaust air and ensure smooth air flow.
◎◎
◎ Can achieve industry-leading level of external static pressure 80Pa
□ Super-long piping conditions,
more convenient design
□ Layered installation, flexibly corresponding to high-rise buildings
For high-rise buildings, machine layer can be left to place outdoor units, or machine room can be set up on each floor. By using exhaust duct to
outdoor units.
Exhaust duct installation
Temperature �
46.9443
45.4512
43.9582
42.4651
40.9721
39.4790
37.9859
36.4929
34.9998
Airflow Schematic
Max. 80Pa
Max. 80Pa
Extra-high external static pressure design
Actual piping length:
and lowest indoor units:
(when outdoor units are higher than indoor units)
165m
15m
70m
(when outdoor units are lower than indoor units) 90m
Long Piping Length
Max. Piping Length: 165m
Total Piping Length: 1000m
Outdoor Units and Indoor Units: 70m
Between Indoor Units: 15m
Between 1st Branch
and Indoor Unit: 90m or less
50m when the ODU is higher than IDU
40m when the ODU is lower than IDU
Note:
value, please contact our technique engineer.
16
Indoor unit can adjust static pressure automatically according to the house structure and installation condition, ensure that the indoor unit operates in the optimum exhaust state.
□ Various modes of supply and return air to coordinate with room decoration designs
g ducted types, on the he maximum extent.
□ Adjustable indoor unit static pressure
*Adopting direct bottom return will make indoor noise increasing 5-8dB (A)
Return air
Supply air Supply air
Side Supply Ceiling Return Side Supply Side Return Ceiling Supply Ceiling Return Side Supply
bottom Return *
Return air hose
Duct
Return air grille
Return air grille
Check grille
Check grille
Check grille
DuctDuct
When the required duct is long,
the static pressure can be set higher;
When the required duct is short,
the static pressure can be set lower.
□ Various models, super multi-connected, easily correspond to the changes in spacial layout
A wide range of outdoor units can be selected according to the actual situation of the building; there are 9 types of indoor unit to choose from; outdoor units and indoor units can be matched and connected freely, which can be selected rationally according to floor location of the owners, interior room
Supply air
Supply air
Supply air
Duct Duct Duct
Return air
Return air
Return air
17
Refrigerant judgment and automatic charge function
The outdoor unit refrigerant charge state can be judged precisely by the overall judgement for the outdoor temperature, indoor unit air inlet and outlet temperature,supper cooling degree, operating pressure and other factors.
Anti-corrosion teratment for Outdoor Units (Optional)
The anti-corrosion treated outdoor units have been designed to provided corrosion resistance against acid rain and salt corrosion.If you need the anti-corrosion type, please contact us.
One-touch test run
The one-touch test run can be operated at the outdoor unit side, and it can also be operated at the indoor unit side, which makes it much earlier for the commissioning.
Refrigerant
6
ON
1 2 3 4 5 6
Cooling mode test run
ON
1 2 3 4 5
Heating mode test run
R e a l i z i n g t e s t r u n
through the controller
at the indoor unit side
R e a l i z i n g t e s t r u n
through the controller
at the indoor unit side
18
Highly Intelligent
Control SystemFujitherma inverter central air-conditioning intelligent control system can be controlled
automatically all by a computer; the overall operation of the system can be easily
learned; it can identify and solve problems in time; meanwhile achieve users’
sub-metering of electricity bill, and make intelligent control more humane.
Various Controllers
ON/OFF
Heat/Cool
Automatic mode
Dehumidification
Fan speed
Louver Setting
Temperature setting
7-Day timer
Auto test run
Error code display
Operation monitoring
Central control
Timer
Group control (ON/OFF)
Mode lock
Air filter cleaning reminding
Wireless controller disable
Check
MAX.number of connectable
indoor units 16
Power supply DC 12~ 17 V
Product dimension (mm)
Appearance
120*120*16
Model name FHYXE-J01HX FHYXE-F01HX FHYXE-G01HX FHYJ-J01HX
Item Wired controller controller
Main
Function
16
DC 12~ 17 V
120*120*19
1
DC 12~ 17 V
86*86*12.4
128
AC1Φ85~ 265V50/60Hz
120*120*52.5
FHYE-Q01X
Wireless controller
16
2 AAA Batteries
125*55*16.5
FHYJE-D02HX
Central controller
160
AC1Φ220V, 50/60Hz
120*120*68
Hig
hly
Inte
llige
nt C
ontr
ol S
yste
mH
ighl
y In
telli
gent
Con
trol
Sys
tem
19
Controllers with more choices, more intelligent and convenient control
There are two system connection patterns:
1.The converter is connected to the router or switch through wired Ethernet. 2.The adapter is connected to the router through WiFi.
Note: The first pattern has better stability, so it is the recommended connection pattern.
Main function
Operate according to a schedule.
Display the alarm code.
Max.16 indoor units can be controlled.
Fujitherma Mobile Intelligent Terminal
IPAD
*The standard parts of this system includes the converter FHYJE-H01HX and the client control software HRM-G01 (it can be downloaded and installed
in the APP STORE), The IPAD is the registered trademark of Apple Inc.
FHYJE-H01HX
Wireless router
LAN
Model name
Input voltage
Maximum operating current
Adapter specifications
FHYJE-H01HX
AC 110~240V 50/60Hz
10mA (220 V)
Isolation Voltage
Operating temperature
Operating humidity
AC 3000V
0℃~40℃
30%RH~60%RH
20
Fujitherma electric charge allocation system consists of
meter reading system and air conditioning management
system. In accordance with the operation time and
capacity output of indoor and outdoor units, the
opening degree of EEV, the electric charge allocation
software allocates the total power consumption to each
indoor unit.
Air conditioning electric charge allocation system
Hi-Dom System Specifications
Hi-Dom air conditioning management system adopts communication bus connection, air conditioning indoor units are connected to the computer
through network converter; the system is all controlled automatically by a computer with powerful functions and simple operation. One single
computer control system can manage 2,048 indoor units.
Hi-Dom air conditioning management system
Main functions○ Running-state monitoring
○ Determine the temperature limit
○ Running records display
○ Controller prohibition function
○ Access control
○ Automatic operation according to settings
○ Multifunction alarm
○ Service Monitoring
Main features
○ Accurate and timely electricity calculation
○ User’s electricity bill reading by the hour
Note:Fujitherma electrical charge calculation software need to customize processing in project according to the users' requirement.
Outdoor Unit
Wireless remote
controller
Wired controller
Indoor unit
Assistant remote
controllerMaster remote
controller
Wired controller Wired controller
Indoor unit
Adapter
Monitoring Center
Client Management Center
Communications
network
Adapter
Shielded twisted pair cable
AC system
AC system
AC system
Electric Charge Allocation System
Power supply
cable
LAN
Electric meter
Network connector
Meter data collector
Adapter
(Hi-Dom)
Model name
FHCCS-H128H2C1YMX
Power Supply
DC 12V
DC 12V
Dimension(mm)
180*110*40
180*110*40
Charging Function
With charging function
FHCCS-H128H2C1NMX Without charging function
Adapter
Adapter
Adapter
All the indoor units and outdoor units connected with one adapter comprise one communication BUS system .
Max.128 indoor units can be connected to a BUS system.
Max.16 adapters can be controlled by one computer.
Max.2048 indoor units are under control.
21
Building Management System
Real-time operation status monitoring for inquiry
Operation order from monitoring center
Compatible to multiple communication protocol of BACnet, RS-485 etc. Connectible to BMS or Smart Home System via FHC-A64BNPX or FHLRSCONXall of which can connect to Max. 64 indoor units.
BACnet
Modbus
Converter specifications
HC-A64BNP
FHC-A64BNPX
Converter
BMS connection
Power supply
Connectable central controller
MAX.number of connectable indoor units
Dimension(L*W*H)
BACnet
AC100~240V±10%(50/60Hz)
FHYJE-D02HX
64
240mm*204mm*70mm
Modbus
AC100~240V±10%(50/60Hz)
FHYJE-D02HX
64
171mm*140mm*43mm
Item
FHC-A64BNPX
Central Station
Central Monitoring BMS
Fire Alarm Disaster Prevention
Fujitherma Supply
Intranet
UPS
BACnet
(Ethernet(LAN))
FHLRSCONX
Intranet
Air Conditioning
Air Conditioning
Air Conditioning
Outdoor Units
Fujitherma
FHLRSCONX
FHLRSCONX
Smart Home Controller
BMS
Indoor UnitsRS-485(232)network
Illumination
i i
i i
Taking full consideration of the various requirements of people for the indoor
products can solve the problems of indoor units well, and make your work and life more healthy.
Extensive outdoor unit products, a single module unit is up to a maximum of 18HP, combined module is up to a maximum of 54HP, which can meet the actual needs of larger and more space.
Fujitherma VRF Plus central air conditioning meets all the needs of people for space environment, interior decoration and human health with high-quality multi-choice indoor units, outdoor units and fresh air units, providing people with a new central air-conditioning experience.
High quality product lineupFujitherma VRF Plus series provides a wide selection of indoor units for indoor decoration and
creates a personalized living space.
There are up to 8 types of indoor units for consumers to choose. Consumers can select in accordance with the interior decoration and design, which brings a perfect combination from comfort to aesthetic experience.
22
Hig
her
Rel
iabi
lity
Hig
her
Rel
iabi
lity
Diverse selection of outdoor units
16HP, 18HP, the capacity of combination module is up to 54HP, with small size, light
combinations to meet their own space requirements according to their actual needs.
Fujitherma Plus
8HP
10HP
12HP
14HP
16HP
18HP
20HP
22HP
24HP
26HP
28HP
30HP
32HP
34HP
36HP
38HP
40HP
42HP
44HP
46HP
48HP
50HP
52HP
54HP
Cooling capacity
(kBtu/h)
13
16
19
23
26
26
33
36
40
43
47
50
53
56
59
64
64
64
64
64
64
64
64
64
MAX. Number of Connectable indoor units
Outdoor unit combinationModelCapacity
THX950WDCXXHX
THX1000WDCXXHX
THX1070WDCXXHX
THX1120WDCXXHX
THX1170WDCXXHX
THX1235WDCXXHX
THX1285WDCXXHX
THX1335WDCXXHX
THX1400WDCXXHX
THX1450WDCXXHX
THX1500WDCXXHX
THX224WDCXXHX
THX335WDCXXHX
THX400WDCXXHX
THX450WDCXXHX
THX500WDCXXHX
THX559WDCXXHX
THX624WDCXXHX
THX680WDCXXHX
THX735WDCXXHX
THX800WDCXXHX
THX850WDCXXHX
THX900WDCXXHX
THX280WDCXXHX
76.5
95.6
114.3
136.5
153.6
170.6
191.1
209.9
235.5
249.1
273.0
290.1
307.2
324.2
341.3
372.0
382.3
402.7
426.6
450.5
464.2
477.8
494.9
511.9
10HP8HP 16HP 18HP14HP12HP
23
24
Note:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27� DB 19� WB, Outdoor air inlet temperature: 35�
Heating conditions: indoor air inlet temperature: 20� DB, Outdoor air inlet temperature: 7� DB 6�
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products.
Outdoor Unit Data
HP.
Outdoor Unit
Items
Air Flow Rate
Outer Dimension
Net Weight
Gross Weight
Compressor Quantity
Condenser Fan Quantity
Cabinet Color
Gas Line
Liquid Line
Max. number of connectable IDU
Max. Piping Length
Height
Noise
Operation
Range
KW
kBtu/h
KW
W/W
W/W
KW
kBtu/h
KW
m³/h
mm
kg
kg
mm
mm
m
m
m
dB(A)
℃ DB
℃ WB
mm
Capacity
Capacity
Combination
1720×950×750 1720×1210×750
Ivory White
AC3Φ380 450V/50Hz~
Consumption Power
EER
COP
Consumption Power
Between ODU & IDU
Between IDUs
Cooling
Heating
~ ~ ~ ~ ~
Packing Dimension
8HP
THX224WCMXXHX THX280WCMXXHX THX335WCMXXHX THX400WCMXXHX THX450WCMXXHX THX500WCMXXHX
22.4
76.5
5.2
4.31 3.89
25.0
85.3
5.5
9300
224
237
1
1
Ф19.05
Ф9.53
13
165
90(70)
15
56
-5 50
-23 19~
1882×1018×828
10HP
28.0
95.6
7.2
31.5
107.5
7.4
10200
225
238
1
1
Ф22.2
Ф9.53
16
165
90(70)
15
57
-5 50
-23 19~
1882×1018×828
12HP
33.5
114.3
8.5
37.5
3.95 3.67 3.44 3,33
4.55 4.26 4.04 4.13 4.04 3.87
128.0
9.3
10500
227
240
1
1
Ф25.4
Ф12.7
19
165
90(70)
15
59
-5 50
-23 19~
1882×1018×828
14HP
40.0
136.5
10.9
45.0
153.6
10.9
11700
312
327
2
1
Ф25.4
Ф12.7
23
165
90(70)
15
59
-5 50
-23 19~
1882×1278×828
16HP
45.0
153.6
13.1
50.0
170.6
12.4
11700
315
330
2
1
Ф28.6
Ф12.7
26
165
90(70)
15
59
-5 50
-23 19~
1882×1278×828
18HP
50.2
170.6
15.1
56.0
191.1
14.5
11700
318
333
2
1
Ф28.6
Ф15.88
26
165
90(70)
15
60
~-5 50
-23 19~
1882×1278×828
Model
Power Supply
Cooling
Heating
25
Ivory White
1720×(1210+1210)×750
20HP
THX559WDCXXHX
THX224WDCXXHX
THX335WDCXXHX
THX224WDCXXHX
THX400WDCXXHX
THX280WDCXXHX
THX400WDCXXHX
THX335WDCXXHX
THX400WDCXXHX
THX400WDCXXHX
THX400WDCXXHX
THX400WDCXXHX
THX450WDCXXHX
56.0
191.1
13.9
63.0
215.0
14.9
19800
1720×(950+950)×750
224+227
237+240
2
2
Ф28.6
Ф15.88
33
165
90(70)
15
61
--
~-5 50
-23 19~
22HP
THX624WDCXXHX
61.5
209.9
16.2
69.0
235.5
16.5
21000
224+312
237+327
3
2
Ф28.6
Ф15.88
36
165
90(70)
15
61
--
~-5 50
-23 19~
24HP
THX680WDCXXHX
69.0
235.5
18.2
77.5
264.5
18.4
21900
225+312
238+327
3
2
Ф28.6
Ф15.88
40
165
90(70)
15
61
--
1720×(950+1210)×750
~-5 50
-23 19~
26HP
THX735WDCXXHX
73.0
249.1
19.7
82.5
281.6
20.3
22200
227+312
240+327
3
2
Ф31.75
Ф19.05
43
165
90(70)
15
62
--
~-5 50
-23 19~
28HP
THX800WDCXXHX
80.0
273.0
21.9
90.0
307.2
22.0
23400
312+312
327+327
4
2
Ф31.75
Ф19.05
47
165
90(70)
15
62
--
~-5 50
-23 19~
30HP
THX850WDCXXHX
85.0
290.1
24.0
95.0
324.2
23.4
23400
312+315
327+330
4
2
Ф31.75
Ф19.05
50
165
90(70)
15
62
--
~-5 50
-23 19~
4.03 3.80 3.80 3.71 3.66 3.55
4.23 4.19 4.22 4.07 4.10 4.06
26
Note:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27� DB 19� WB, Outdoor air inlet temperature: 35�
Heating conditions: indoor air inlet temperature: 20� DB, Outdoor air inlet temperature: 7� DB 6�
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products.
4." * " Means the main model of outdoor unit, For example, the main outdoor unit model of 8HP product is HVR-252W, the model is HVR-252W/SG1FZBp.
Outdoor unit comprehensive parameters
HP.
Outdoor Unit
Items
Air Flow Rate
Outer Dimension
Net Weight
Gross Weight
Compressor Quantity
Condenser Fan Quantity
Cabinet Color
Gas Line
Liquid Line
Max. number of connectable IDU
Max. Piping Length
Height
Noise
Operation
Range
KW
kBtu/h
KW
KW
kBtu/h
KW
m³/h
mm
kg
kg
mm
mm
m
m
m
dB(A)
℃ DB
℃ WB
1720×(950+950+1210)×7501720×(1210+1210)×750
Capacity
Cooling
Heating Capacity
Combination
AC3Φ380 450V/50Hz
Consumption Power
EER
COP
Consumption Power
Between ODU & IDU
Between IDUs
Cooling
Heating
Packing Dimension mm
Ivory White
32HP
THX900WDCXXHX
90.0
3.44 3.37 3.32 3.84 3.68 3.64
4.04 3.92 3.81 3.98 4.02 3.97
307.2
26.2
100.0
341.3
24.8
23400
315+315
330+330
4
2
Ф31.75
Ф19.05
53
165
90(70)
15
62
-23 19~
~-5 50
--
36HP
THX1000WDCXXHX
100.0
341.3
30.2
112.0
382.3
29.4
23400
318+318
333+333
4
2
Ф38.1
Ф19.05
59
165
90(70)
15
63
-23 19~
~-5 50
--
38HP
THX1070WDCXXHX
109.0
372.0
28.4
118.0
402.7
29.7
32700
227+227+312
240+240+327
4
3
Ф38.1
Ф19.05
64
165
90(70)
15
64
-23 19~
~-5 50
--
40HP
THX1120WDCXXHX
112.0
382.3
30.5
125.0
426.6
31.1
32700
227+227+315
240+240+330
4
3
Ф38.1
Ф19.05
64
165
90(70)
15
64
-23 19~
~-5 50
--
42HP
THX1170WDCXXHX
118.0
402.7
32.5
132.0
450.5
33.3
32700
227+227+318
240+240+333
4
3
Ф38.1
Ф19.05
64
165
90(70)
15
64
-23 19~
~-5 50
--
34HP
THX950WDCXXHX
95.0
324.2
28.2
106.0
361.8
27.1
23400
315+318
330+333
4
2
Ф31.75
Ф19.05
56
165
90(70)
15
63
-23 19~
~-5 50
--
Model
Power Supply~
THX450WDCXXHX
THX450WDCXXHX
THX450WDCXXHX
THX500WDCXXHX
THX500WDCXXHX
THX500WDCXXHX
THX335WDCXXHX
THX335WDCXXHX
THX400WDCXXHX
THX335WDCXXHX
THX335WDCXXHX
THX450WDCXXHX
THX335WDCXXHX
THX335WDCXXHX
THX500WDCXXHX
W/W
W/W
27
1720×(950+1210+1210)×750 1720×(1210+1210+1210)×750
Ivory White
44HP
THX1235WDCXXHX
125.0
3.60
4.00
3.58 3.51 3.40 3.35 3.32
3.98 3.87 3.85 3.83 3.75
426.6
34.8
140.0
477.8
35.0
33900
227+312+318
240+327+333
5
3
Ф38.1
Ф19.05
64
165
90(70)
15
64
-23 19~
~-5 50
--
46HP
THX1285WDCXXHX
132.0
450.5
36.9
145.0
494.9
36.5
33900
227+315+318
240+330+333
5
3
Ф38.1
Ф19.05
64
165
90(70)
15
64
-23 19~
~-5 50
--
48HP
THX1335WDCXXHX
136.0
464.2
38.8
150.0
511.9
38.8
33900
227+318+318
240+333+333
5
3
Ф38.1
Ф19.05
64
165
90(70)
15
65
-23 19~
~ -5 50
--
50HP
THX1400WDCXXHX
140.0
477.8
41.2
155.0
529.0
40.3
35100
312+318+318
327+333+333
6
3
Ф38.1
Ф19.05
64
165
90(70)
15
65
-23 19~
~ -5 50
--
52HP
THX1450WDCXXHX
145.0
494.9
43.3
160.0
546.1
41.8
35100
315+318+318
330+333+333
6
3
Ф38.1
Ф19.05
64
165
90(70)
15
65
-23 19~
~-5 50
--
54HP
THX1500WDCXXHX
150.0
511.9
45.3
165.0
563.1
44.1
35100
318+318+318
333+333+333
6
3
Ф38.1
Ф19.05
64
165
90(70)
15
65
-23 19~
~ -5 50
--
THX335WDCXXHX
THX400WDCXXHX
THX500WDCXXHX
THX335WDCXXHX
THX450WDCXXHX
THX500WDCXXHX
THX335WDCXXHX
THX500WDCXXHX
THX500WDCXXHX
THX400WDCXXHX
THX500WDCXXHX
THX500WDCXXHX
THX450WDCXXHX
THX500WDCXXHX
THX500WDCXXHX
THX500WDCXXHX
THX500WDCXXHX
THX500WDCXXHX
28
Outdoor unit THX559~680 THX735~1000
Branch Pipe FHFQ-M22FX FHFQ-M32FX
Piping Connection Kit
Outdoor unit THX240~280 THX335~450
Branch Pipe FHFQ-102FX FHFQ-162FX
THX500~680
FHFQ-242FX
THX735~1500
FHFQ-302FX
Total Indoor Unit (kBtu/h) Q<57.3 57.3≤Q<86.0
Gas (Фmm) Ф15.88 Ф19.05
86.0≤Q<114.3
Ф22.2
114.3≤Q<153.6
Ф25.4
Liquid (Фmm) Ф9.53 Ф9.53 Ф9.53 Ф12.7
Branch Pipe FHFQ-102FX FHFQ-102FX FHFQ-102FX FHFQ-162FX
153.6≤Q<172.0
Ф28.6
Ф12.7
FHFQ-162FX
172.0≤Q<248.5
Ф28.6
Ф15.88
FHFQ-242FX
248.5≤Q<344.7
Ф31.75
Ф19.05
FHFQ-302FX
Q≥344.7
Ф38.1
Ф19.05
FHFQ-302FX
Outdoor Unit THX1070~1500
Branch Pipe 1
Branch Pipe 2
FHFQ-M32FX
FHFQ-M32FX
Double Module Combination Model
Three Module Combination Model
First Branch Pipe
First Branch Pipe~Last Branch Pipe
Branch Pipe 1 Branch Pipe 2
Outdoor Unit A
Branch Pipe To Indoor Units
Outdoor Unit A Outdoor Unit B
Branch Pipe To Indoor Units
Outdoor Unit B Outdoor Unit A
Outdoor Unit B Outdoor Unit C
To Indoor Units Branch Pipe 2 Branch Pipe 1
Outdoor Unit C Outdoor Unit B Outdoor Unit A
To Indoor Units
Last Branch Pipe~Indoor Unit
NOTES:
1. When liquid pipe length of indoor unit(07~18kBtu/h) is more than 15m, please change the liquid pipe dimension from Φ6.35 into Φ9.53.
Indoor Unit(kBtu/h)
Pipe Size (Φmm)
Gas Pipe Liquid Pipe Max. Liquid Pipe Length
12.7
15.88
15.88
19.05
22.2
6.35
9.53
6.35*1
9.53
9.53
15
40
15
40
4076
96
7~14
17~18
22~54
29
Indoor Units
Extensive indoor unit products
Fujitherma VRF Plus series has a variety of indoor units to choose from, together with interior decoration, it brings you individual home space to enjoy what you want.
Meet the needs of individual space experience
kBtu/h 7 9 12 14 17 18 22 24 27 30 38 48 54 76 96
0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 3.3 4.0 5.0 6.0 8 10
Slim Ceiling Ducted
HP
ModelType
Ceiling Ducted
(Low Static Pressure)
Ceiling Ducted
(High Static Pressure)
Low-Height Ceiling Ducted
4-Way Cassette
Ceiling & Floor
Wall Mounted
Wall Mounted
Floor Concealed
Compact 4-Way Cassette
30
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB)
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
The sound pressure level is based on following conditions: 1.5m beneath the unit. With discharge
duct (2.0m) and return duct(1.0m)
The above data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation
mode and the room structure.
*1: AC3Φ, 380 415V/50Hz, *2: AC3Φ, 380V/60Hz
2.
3.
Nominal Heating
Capacity
Nominal Cooling
Capacity
Model
Power Supply
Indoor Unit
Approximate Packing
Measurement
Indoor Fan Air Flow Rate
(High/Medium/Low)
Motor Power
Refrigerant Piping Connection
Liquid Line
R410A(Nitrogen-charged for Corrosion-resistance)
Flare-nut Connection(with Flare Nuts) Brazing
VP25(Outer Diameter Φ32 )
Ceiling Ducted Type (Low Static Pressure)
Gas Line
Condensate Drain
External Static Pressure
Sound Pressure Level
(High/Medium/Low)
270×(650+75)×720 270×(900+75)×720 350×(900+75)×800350×(1300+75)
×800
Net Weight
Refrigerant
Outer Dimensions
(H x W x D)
DTHX
22HHX
DTHX
28HHX
DTHX
36HHX
DTHX
43HHX
DTHX
50HHX
DTHX
56HHX
DTHX
63HHX
DTHX
71HHX
DTHX
84HHX
DTHX
90HHX
DTHX
112HHX
DTHX
142HHX
DTHX
160HHX
DTHX
250HHX
470×1060
×1120
DTHX
280HHX
470×1250
×1120
AC1Φ 220 240V
/50Hz~
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
dB(A)
mm
kg
m3/h
W
mm
mm
Pa
m3
2.2
1,900
7,500
2.8
2,400
9,600
30-26-24
25
/360480/420
110
Φ6.35
Φ12.7
30
0.21
2.8 3.6 4.3 5.0 5.6 6.3 7.1 8.4 9.0 11.2 14.2 16.0 22.4 28.0
2,400
9,600
3.3
2,800
11,300
30-26-24
25
/360480/420
110
Φ6.35
Φ12.7
30
0.21
3,100
12,300
4.2
3,600
14,300
25
150
32-30-28
/540
780/660
Φ6.35
Φ12.7
30
0.21
/540
780/660
Φ6.35
Φ12.7
30
0.21
150
25
3,700
14,700
4.9
4,200
16,700
32-30-28
4,300
17,100
5.6
4,800
19,100
34
/660900/780
150
Φ6.35
Φ15.88
30
0.27
4,800
19,100
6.5
5,600
22,200
5,400
21,500
7.5
6,500
25,600
6,100
24,200
8.5
7,300
29,000
7,200
28,700
9.6
8,300
32,800
7,700
30,700
10.0
8,600
34,100
9,600
38,200
12,200
44,400
11,200
13.0
61,400
15,500
18.0
54,600
55,600
14,000
16.3
48,500
13,800
107,500
27,100
31.5
95,600
24,100
85,300
21,500
25.0
76,500
19,300
41-38-3339-35-3138-34-3038-34-3034-32-3034-32-3033-31-2933-31-29 525043-39-34
106945656444444343434
/15002200/1900
/15002150/1800
/1150
1550/1350
/720
960/840
/720
960/840
/660900/780
1120950430430300190150150
Φ9.53Φ9.53Φ9.53Φ9.53Φ6.35
Φ15.88Φ15.88Φ15.88 Φ22.2Φ19.05
1006060606060303030 100
1.060.900.520.520.380.380.380.270.270.27
Φ9.53Φ9.53Φ9.53Φ9.53Φ9.53
Φ15.88Φ15.88Φ15.88Φ15.88Φ15.88
/1150
1550/1350
/1150
1550/1350
300 300
3480 4320
Ceiling Ducted Type(Low Static Pressure)
less than 270mm in height can be easily fit into the limited space in the false ceiling(7.5-24.2KBtu/h).
NOTE:
When bottom air inlet is adopted, sound pressure will increase according to factors
such as installation mode and the room structure.
By introducing fresh outdoor air and being equipped with air filter to keep indoor air clean.
Cooling/heating air distributed from the unit to indoor space through ducts, which creates a comfortable environment.
Drain-up mechanism can be supplied as optional part.
Installation Space-saving Fresh indoor Air
Excellent Air Flow
Optional PartsFlexibly supports a wide range of installation
Minimum 5mm
270mm
7.5-24.2Btu/h False Ceiling
Indoor Unit
Duct
Canvas Duct(Field-supplied) Air Filter,Air Grid
(Field-supplied)
Maximum 900mm
Condensate Drain-up
Air Inlet
~
31
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB)
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
The sound pressure level is based on following conditions: 1.5m beneath the unit. With discharge
duct (2.0m) and return duct(1.0m)
The above data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation
mode and the room structure.
*1: AC3Φ, 380 415V/50Hz, *2: AC3Φ, 380V/60Hz
2.
3.
Nominal Heating
Capacity
Nominal Cooling
Capacity
Model
Power
Supply
R410A(Nitrogen-charged for Corrosion-resistance)
Flare-nut Connection(with Flare Nuts) Brazing
VP25(Outer Diameter Φ32 )
Indoor Unit
Approximate Packing
Measurement
Indoor Fan Air Flow Rate
(High/Medium/Low)
Motor Power
Refrigerant Piping Connection
Liquid Line
Ceiling Ducted Type (High Static Pressure)
Gas Line
Condensate Drain
External Static Pressure
Sound Pressure Level
(High/Medium/Low)
270×(650+75) ×720 270×(900+75)×720 350×(900+75)×800 350×(1300+75)×800470×1060
×1120
470×1250
×1120
Net Weight
Refrigerant
Outer Dimensions
(H x W x D)
DHTHX
22HHX
DHTHX
28HHX
DHTHX
36HHX
DHTHX
43HHX
DHTHX
50HHX
DHTHX
56HHX
DHTHX
63HHX
DHTHX
71HHX
DHTHX
84HHX
DHTHX
90HHX
DHTHX
112HHX
DHTHX
142HHX
DHTHX
160HHX
DHTHX
250HHX
DHTHX
280HHX
480/420/360
480/420/360
780/660/540
900/780/660
960/840/720
1600/1400/1150
2100/1750/1450
2150/1800/1550
46503480780/660/540
900/780/660
960/840/720
1600/1400/1150
1600/1400/1150
AC1Φ 220 240V/50Hz
~
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
dB(A)
mm
kg
m3/h
W
mm
mm
Pa
m3
2.2
Φ12.7
Φ6.35
110
25
33-31-29
9,600
2,400
2.8
7,500
1,900
50(80)
0.21
Φ12.7
Φ6.35
110
25
33-31-29
11,300
2,800
3.3
9,600
2,400
2.8
0.21
50(80)
0.21
50(80)
Φ12.7
Φ6.35
150
25
33-31-29
14,300
3,600
4.2
12,300
3,100
3.6
50(80)
Φ12.7
Φ6.35
150
25
33-31-29
16,700
4,200
4.9
14,700
3,700
4.3
0.21
Φ6.35
150
34
34-32-30
19,100
4,800
5.6
17,100
4,300
5.0
0.27
50(80)
Φ15.88
0.27
50(80)
Φ15.88
Φ6.35
150
34
34-32-30
22,200
5,600
6.5
19,100
4,800
5.6
36-34-32
25,600
6,500
7.5
21,500
5,400
0.27
50(80)
Φ15.88
Φ9.53
150
34
6.3
36-34-32
29,000
7,300
8.5
24,200
6,100
7.1
Φ15.88
Φ9.53
190
34
0.27
50(80)
32,800
8,300
9.6
28,700
7,200
8.4
0.38
120(90)
Φ15.88
Φ9.53
300
44
41-39-34
44
41-39-34
34,100
8,600
10.0
30,700
7,700
9.0
0.38
120(90)
Φ15.88
Φ9.53
300 300
44
43-40-36
44,400
11,200
13.0
38,200
9,600
11.2
0.38
120(90)
Φ15.88
Φ9.53 Φ9.53
430
56
44-41-36
55,600
14,000
16.3
48,500
12,200
14.2
0.52
120(90)
Φ15.88
43-40-37
61,400
15,500
18.0
54,600
13,800
16.0
0.52
120(90)
Φ15.88
Φ9.53
430
56
1030
94
52
85,300
21,500
25.0
76,500
19,300
22.4
Φ19.05
Φ9.53
220
0.90
106
54
107,500
27,100
31.5
95,600
24,100
28.0
1.06
220
Φ22.2
Φ9.53
1280
Ceiling Ducted Type(High Static Pressure)
less than 270mm in height can be easily fit into the limited space in the false ceiling(7.5-24.2KBtu/h).
NOTE:
When bottom air inlet is adopted, sound pressure will increase according to factors
such as installation method and the room structure.
By introducing fresh outdoor air and being equipped with air filter to keep indoor air clean.
Cooling/heating air distributed from the unit to indoor space through ducts, which creates a comfortable environment.
Drain-up mechanism can be supplied as optional part.
Installation Space-saving Fresh indoor Air
Excellent Air Flow
Optional PartsFlexibly supports a wide range of installation
conditions at site
Minimum 5mm
270mm
7.5-24.2Btu/h False Ceiling
Indoor Unit
Duct
Canvas Duct(Field-supplied) Air Filter,Air Grid
(Field-supplied)
Maximum 900mm
Condensate Drain-up
Air Inlet
~
32
Indoor Unit
R410A(Nitrogen-charged for Corrosion-resistance)
Flare-nut Connection(with Flare Nuts)
VP25(Outer Diameter Φ32 )
Low-height Ceiling Ducted Type
Nominal Heating
Capacity
Nominal Cooling
Capacity
Model
Power Supply
Approximate Packing
Measurement
Indoor Fan Air Flow Rate
(High/Medium/Low)
Motor Power
Refrigerant Piping Connection
Liquid Line
Gas Line
Condensate Drain
External Static Pressure
Sound Pressure Level
(High/Medium/Low)
Net Weight
Refrigerant
Outer Dimensions
(H x W x D)
DHTHXSL
22HHX
DHTHXSL
28HHX
DHTHXSL
36HHX
DHTHXSL
43HHX
DHTHXSL
50HHX
DHTHXSL
56HHX
DHTHXSL
63HHX
DHTHXSL
71HHX
AC1Φ 220 240V/50Hz
~
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
dB(A)
kg
mm
m3/h
W
mm
mm
Pa
m3
27-24-21
11,300
2,800
3.3
9,600
2,400
2.8
0.15
10(30)
Φ12.7
Φ6.35
50
500/440/350
20
192×900×447
27-24-21
9,600
2,400
2.8
7,500
1,900
2.2
10(30)
Φ12.7
Φ6.35
70
640/590/520
21
192×900×447
32-30-27
14,300
3,600
4.2
12,300
3,100
3.6
0.15
10(30)
Φ12.7
Φ6.35
50
500/440/350
20
192×900×447
0.15
5,600
6.5
19,100
4,800
5.6
0.18
10(30)
Φ15.88
Φ6.35
100
870/750/630
26
192×1170×447
34-30-28
19,100
4,800
5.6
17,100
4,300
5.0
0.15
10(30)
Φ12.7
Φ6.35
70
640/590/520
21
192×900×447
32-30-27
16,700
4,200
4.9
14,700
3,700
4.3
Φ15.88
Φ9.53
110
950/820/170
26
192×1170×447
36-32-29
25,600
6,500
7.5
21,500
5,400
6.3
0.18
10(30)
Φ15.88
Φ6.35
100
870/750/630
26
192×1170×447
34-30-28
22,200
0.18
10(30)
Φ15.88
Φ9.53
110
950/820/170
26
192×1170×447
36 -32-29
29,000
7,300
8.5
24,200
6,100
7.1
0.18
10(30)
Installation Space-saving
Drain-up Mechanism as Standard part
Broad Range of External Static Pressure
Satisfy Varied Requests on Installation
Minimum 5mm
False Ceiling
Elastic Hose
Drain-up Length 900mm
192mm
Low-height
Ceiling Ducted Type
With a height of 192mm may be easily installed inside the low height residential ceiling.
Drain-up length achieves 900mm which enables convenient drain piping and enlarges the flexibility of installation.
10Pa(0r30pa), flexibly supports a wide range of installation conditions at site, e.g. longer ducts and shorter ducts supplied.
Available air inlet as rear or bottom entry, consumers can choose relevant air inlet mode according to the practical installation space.
(Installation Diagram of Air Bottom Inlet)
Indoor Unit
Duct
Canvas Duct(Field-supplied) Air Filter,Air Grid
(Field-supplied)Air Inlet
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB)
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
The sound pressure level is based on following conditions: 1.5m beneath the unit. With discharge duct
(2.0m) and return duct(1.0m)
The above data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation
mode and the room structure.
2.
33
Nominal Heating
Capacity
Nominal Cooling
Capacity
AC1Φ 220 240V/50Hz
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
dB(A)
mm
kg
m3/h
W
mm
mm
Pa
m3
Model
Power Supply
R410A(Nitrogen-charged for Corrosion-resistance)
Flare-nut Connection(with Flare Nuts)
VP25(Outer Diameter Φ32 )
Indoor Unit
Approximate Packing
Measurement
Indoor Fan Air Flow Rate
(High/Medium/Low)
Motor Power
Refrigerant Piping Connection
Liquid Line
Slim Ceiling Ducted Type
Gas Line
Condensate Drain
External Static Pressure
Sound Pressure Level
(High/Medium/Low)
Net Weight
Refrigerant
2.2
1,900
7,500
2.8
2,400
9,600
27-23-21
192×700×602
21
450/380/335
50
Φ6.35
Φ12.7
10(30)
0.15
2.8
2,400
9,600
3.3
2,800
11,300
27-23-21
192×700×602
21
450/380/335
50
Φ6.35
Φ12.7
10(30)
0.15
3.6
3,100
12,300
4.2
3,600
14,300
31-29-27
192×700×602
21
590/510/470
60
Φ6.35
Φ12.7
10(30)
0.15
4.3
3,700
14,700
4.9
4,200
16,700
31-29-27
192×700×602
21
590/510/470
60
Φ6.35
Φ12.7
10(30)
0.15
Outer Dimensions
(H x W x D)
DHTHXSSL22HHX DHTHXSSL28HHX DHTHXSSL36HHX DHTHXSSL43HHX~
Installation Space-saving
Drain-up Mechanism as Standard part
Broad Range of External Static Pressure
Satisfy Varied Requests on Installation
Minimum 5mm
False Ceiling
700mm
Elastic Hose
Drain-up Length 900mm
(Installation Diagram of Air Bottom Inlet)
Indoor Unit
Duct
Canvas Duct(Field-supplied) Air Filter,Air Grid
(Field-supplied)Air Inlet
Slim Ceiling Ducted Type
With a width of 700mm may be easily installed inside narrow residential ceiling.
Drain-up length achieves 900mm which enables convenient drain piping and enlarges the flexibility of installation.
10Pa(0r30pa), flexibly supports a wide range of installation conditions at site, e.g. longer ducts and shorter ducts supplied.
Available air inlet as rear or bottom entry, consumers can choose relevant
air inlet mode according to the practical installation space.
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB)
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
The sound pressure level is based on following conditions: 1.5m beneath the unit. .
The above data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation
mode and the room structure.
2.
Nominal Heating
Capacity
Nominal Cooling
Capacity
AC1Φ 220 240V/50Hz
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
dB(A)
mm
kg
m3/h
W
mm
mm
Pa
m3
Model
Power Supply
R410A(Nitrogen-charged foff r Corrosion-resistance)
Flare-nut Connection(with Flare Nuts)
VP25(Outer Diameter Φ32 )
Approximate Packing
Measurement
Indoor Fan Air Flow Rate
(High/Medium/Low)
Motor Power
Refrigerant Piping Connection
Liquid Line
Gas Line
Condensate Drain
External Static Pressure
Sound Pressure Level
(High/Medium/Low)
Net Weight
Refrigerant
2.2
1,900
7,500
2.8
2,400
9,600
27-23-21
192×700×602
21
450/380/335
50
Φ6.35
Φ12.7
10(30)
0.15
2.8
2,400
9,600
3.3
2,800
11,300
27-23-21
192×700×602
21
450/380/335
50
Φ6.35
Φ12.7
10(30)
0.15
3.6
3,100
12,300
4.2
3,600
14,300
31-29-27
192×700×602
21
590/510/470
60
Φ6.35
Φ12.7
10(30)
0.15
4.3
3,700
14,700
4.9
4,200
16,700
31-29-27
192×700×602
21
590/510/470
60
Φ6.35
Φ12.7
10(30)
0.15
Outer Dimensions
(H x W x D)
DHTHXSSL22HHX DHTHXSSL28HHX DHTHXSSL36HHX DHTHXSSL43HHX~
34
Nominal Heating
Capacity
Nominal Cooling
Capacity
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
dB(A)
mm
kg
m3/h
W
mm
mm
m3
mm
kg
m3
Model
Power Supply
Indoor Unit
Approximate PackingMeasurement
Approximate PackingMeasurement
Standard Accessories
Panel Model
Indoor Fan Air Flow Rate(High/Medium/Low)
Motor Power
Refrigerant Piping Connection
Liquid Line
4-Way Cassette Type
Gas Line
Condensate Drain
Sound Pressure Level(High/Medium/Low)
248 x 840 x 840 298 x 840 x 840
Net Weight
Refrigerant
3.6
3,100
12,300
4.2
3,600
14,300
31-29-27
22
50
Φ6.35
Φ12.7
0.22
6
0.08
4.3
3,700
14,700
4.9
4,200
16,700
31-29-27
22
50
Φ6.35
Φ12.7
0.22
6
0.08
5.0
4,300
17,100
5.6
4,800
19,100
32-30-27
23
50
Φ6.35
Φ15.88
0.22
6
0.08
5.6
4,800
19,100
6.5
5,600
22,200
32-30-27
23
50
Φ6.35
Φ15.88
0.22
6
0.08
6.3
5,400
21,500
7.5
6,500
25,600
33-31-29
23
60
Φ9.53
Φ15.88
0.22
6
0.08
7.1
6,100
24,200
8.5
7,300
29,000
33-31-29
23
60
Φ9.53
Φ15.88
0.22
6
0.08
8.4
7,200
28,700
9.6
8,300
32,800
36-34-32
24
90
Φ9.53
Φ15.88
0.26
6
0.08
9.0
7,700
30,700
10.0
8,600
34,100
36-34-32
24
90
Φ9.53
Φ15.88
0..26
6
0.08
11.2
9,600
38,200
13.0
11,200
44,400
41-38-35
27
120
Φ9.53
Φ15.88
0.26
6
0.08
14.2
12,200
48,500
16.3
14,000
55,600
44-39-36
27
150
Φ9.53
Φ15.88
0.26
6
0.08
16.0
13,800
54,600
18.0
15,500
61,400
44-42-38
27
160
Φ9.53
Φ15.88
0.26
6
0.08
Outer Dimensions(H x W x D)
2.8
2,400
9,600
3.3
2,800
11,300
30-29-27
22
40
Φ6.35
Φ12.7
0.22
6
0.08
Cabinet Color
Net Weight
Outer Dimensions(H x W x D)
R410A(Nitrogen-charged for Corrosion-resistance)
Flare-nut Connection(with Flare Nuts)
VP25(Outer Diameter Φ32 )
HPE-A-NA
Neutral White
Suspension Brackets
37 x950 x 950
780/720/660
900/810
/720960/840
/720
1140/1020
/840
1200/1020
/900
1560/1380
/1200
1920/1680
/1440
2040/1740
/1500
2220/1920
/1620
900/810
/720
1560/1380
/1200
AC1Φ 220 240V/50Hz
~
CTHX
28HHX
CTHX
56HHX
CTHX
50HHX
CTHX
43HHX
CTHX
36HHX
CTHX
142HHX
CTHX
112HHX
CTHX
90HHX
CTHX
84HHX
CTHX
71HHX
CTHX
63HHX
CTHX
160HHX
960/840
/720
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB)
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
The sound pressure level is based on following conditions: 1.5m beneath the unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
2.
Extremely Quit Operation
Unified Panel Sizes
Compact and Thin
Drain-up Mechanism as Standard Part
With broad range of air supply, is suitable to be
used in high ceiling and great space
Input power reduced by applying of new developed
DC fan motor
Body height easily adjustable in the corner pockets
4-Way Cassette Type
By employing a super-high-stream turbo fan (Three-dimensional
has been improved. With the under damping slit mounted near the center of the revolving shaft, the abnormal noise which is unique to DC motors caused by the number of magnetic poles and revolution speed of the motor,is reduced.
Panel sizes are unifide to a 950mm square, neat and elegance, and well harmonized with decoration.
The height of the unit is just 248mm (Less than 24.2Btu/h), so it can be installed in a small space inside a ceiling.
Employed several new technologies such as a ferritic magneticsurface-mounted rotor, centralized winding system and split core
and lighter.
A pocket is provided for each of the four panel corners, so that the body height can be adjusted easily without removing the panel.
35
Convenience for washing filter
“FILTER” will be shown on the display of the remote control switch after
approximately 1200 hours operation. And the filter can be taken out
conveniently.
Drain-up Mechanism as Standard Part
Compact
4-Way Cassette Type
Maximum
Height 740mm
Condensate Drain-up
Broad range of air supply
The recommended installation height is 2.5 meter, and it’s can also
be adapted for high ceiling installation, by using the fan moter speed-up
setting. To shift to SHi setting , connect cable terminal of SHi to the power
line of the fan moter.
Compact Design
Panel sizes are unifide to a 650mm square, neat and elegance,
and fit small ceiling panel, making installation easier in grid ceilings.
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB)
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
The sound pressure level is based on following conditions: 1.5m beneath the unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
2.
Indoor Unit
R410A(Nitrogen-charged for Corrosion-resistance)
Flare-nut Connection(with Flare Nuts)
VP25(Outer Diameter Φ32 )
Nominal Heating Capacity
Nominal Cooling Capacity
Model
Power Supply
Approximate Packing
Measurement
Indoor Fan Air Flow Rate
(High/Medium/Low)
Motor Power
Refrigerant Piping Connection
Liquid Line
Gas Line
Condensate Drain
Sound Pressure Level
(High/Medium/Low)
Net Weight
Refrigerant
Outer Dimensions
(H x W x D)
CSTHX22HHXAC1Φ 220 240V/50Hz
~
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
dB(A)
kg
mm
m3/h
W
mm
mm
m3
39-34-30
11,300
2,800
3.3
9,600
2,400
2.8
Φ12.7
Φ6.35
63
20
270×570×570
39-34-30
9,600
2,400
2.8
7,500
1,900
2.2
Φ12.7
Φ6.35
63
20
39-34-30
14,300
3,600
4.2
12,300
3,100
3.6
Φ12.7
Φ6.35
63
20
0.18
Φ15.88
Φ6.35
89
20
44-41-37
19,100
4,800
5.6
17,100
4,300
5.0
Φ12.7
Φ6.35
71
20
41-38-33
16,700
4,200
4.9
14,700
3,700
4.3
CSTHX28HHX CSTHX36HHX CSTHX43HHX CSTHX50HHX
Compact 4-Way Cassette Type
Standard Accessories
Panel Model
Cabinet Color
Outer Dimensions
(H x W x D)
Net Weight
Approximate Packing
mm
kg
m3
30×650×650
2.4
0.07
Suspension Drackets
HPE-CR-NA
Neutral White
0.18 0.18 0.18 0.18
30×650×650 30×650×650 30×650×650 30×650×650
2.4 2.4 2.4 2.4
0.070.070.070.07
270×570×570 270×570×570 270×570×570 270×570×570
570/480/384 570/480/384 570/480/384 654/564/456 792/690/588
*The wireless remote controller HYE-Q01 is standard for Compact 4-Way Cassette Type
36
The Ceiling & Floor type creates comfortable and healthy environment
by introducing fresh outdoor air.
*The wireless remote controller HYE-Q01 is standard for Ceiling & Floor Type
Fresh air in-take design
The unit can be installed either horizontally on the ceiling or vertically
against the wall.The ceiling installation method saves room space, and
the floor installation method helps prevent losing warm air. Vertical air
flow and horizontal airflow can be adjusted; Fulfill the optimum airflow
organization, more comfortable.
Convenient installation & Comfortable air circulation
New Fashion Design Appearance and High Quality
The fashionable design and streamline appearance make it a perfect
choice for users.The integrative side panel makes the whole unit more
concordant.Huge air outlet with an integrative large louver realizes high
air volume and low noise.
3D airflow, comfortable air circulation
Vertical air flow and horizontal airflow can be adjusted; Fulfill the
optimum air organization, more comfortable.
NOTES:
1.The nominal cooling capacity and heating capacity are based on following condations:
Cooling Operation Condations
Indoor Air Inlet Temperature: 27℃ DB(80°F DB)19℃ WB(66.2°F DB)Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)Piping Length: 5.0Meter Piping Lift: 0Meter
Heating Operation Condations
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)Outdoor Air Inlet Temperature:7℃ DB(45°F DB)6℃ DB(43°F DB)
2.The sound pressure level is based on following condations:
1.0m beneath the unit,1.0m from Discharge Grille.
The above data was measured in an anechoic chamber so
that reflected sound should be taken into consideration in the
field. When bottom air inlet is adopted,sound pressure will
increase according to factors such as installation mode and
the room structure.
Ceiling & Floor Type
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
W
m³/min
dB(A)
mm
kg
kg
FTHXEV50HHX
5.0
4,300
17,100
5.6
4,800
19,100
40
13/11/9
39/35/30
990×680×230
31
38
1110×830×340
14.2
16
FTHXEV56HHX
5.6
4,800
19,100
6.5
5,600
22,200
40
13/11/9
39/35/30
990×680×230
31
38
1110×830×340
14.2
16
FTHXEV63HHX
6.3
5,400
21,500
7.5
6,500
25,600
70
16.1/14//11.3
45/41/37
990×680×230
32
39
1110×830×340
17.8
20
FTHXEV71HHX
7.1
6,100
24,200
8.5
7,300
29,000
70
16.1/14//11.3
45/41/37
990×680×230
32
39
1110×830×340
17.8
20
FTHXEV84HHX
8.4
7,200
28,700
9.6
8,300
32,800
70
18.2/15.2/12.2
43/39/34
1285×680×230
39
46
1400×830×340
19.8
22.3
FTHXEV90HHX
9.0
7,700
30,700
10.0
8,600
34,100
80
19.4/16.3/13.3
45/40/36
1285×680×230
40
47
1400×830×340
21.2
23.5
FTHXEV112HHX
11.2
9,600
38,200
13.0
11,200
44,400
130
24.8/20.5/16.3
51/46/40
1285×680×230
41
48
1400×830×340
27
29.2
FTHXEV142HHX
14.2
12,200
48,500
16.3
14,000
55,600
160
33/28/23
50/46/42
1580×680×230
47
56
1690×830×340
36
37.4
VP25(Outer Diameter Φ32)
Flare-nut Connection(with Flare Nuts)
R410A
220-240V/50HZ
Ceiling & Floor type
(1/4)
(5/8)
Φ15.88
Φ6.35
(in.)
(in.)
mm
mm
mm³/min
mm³/min
mm
(1/4)
(5/8)
Φ15.88
Φ6.35
(3/8)
(5/8)
Φ15.88
Φ9.53
(3/8)
(5/8)
Φ15.88
Φ9.53
(3/8)
(5/8)
Φ15.88
Φ9.53
(3/8)
(5/8)
Φ15.88
Φ9.53
(3/8)
(5/8)
Φ15.88
Φ9.53
(3/8)
(5/8)
Φ15.88
Φ9.53
(H×W×D)
(H×W×D)
Speed-up Setting HH1
Speed-up Setting HH2
Indoor Unit
Model
Power Source
Norminal Cooling Capacity
Normal Heating Capacity
Motor Power input
Air Flow Rate Hi/Me/Lo
Sound Pressure
Outer Dimensions
Net Weight
Gross Weight
Refrigerant
Refrigerant Piping Connection
Liquid Line
Gas Line
Condensate Drain
Outer Dimensions of Package
37
*The wireless remote controller HYE-Q01 is standard for Wall Mounted Type
Elegant design, harmonizing with
any type of interior design
Anti-mold filter
Compact and light weight,
allowing easy installation
Use the new “Wonder Flap”
Cabinet Color
Refrigerant
Motor Power
Refrigerant Piping Connection
Condensate Drain
Approximate Packing
Measurement
Standard Accessories
Liquid Line
Gas Line
Net Weight
Outer Dimensions
(H x W x D)
Indoor Fan Air Flow Rate
(Cooling/Heating)
Nominal Heating
Capacity
Nominal Cooling
Capacity
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
dB(A)
mm
kg
m3/h
W
mm
mm
m3
Model
Power Supply
Indoor Unit Wall Mounted Type
Sound Pressure Level
(High/Medium/Low)
Silky White
305 x 870 x 225
2.8
2,400
9,600
3.2
2,800
10,900
38-36-33
9
650/600/550
30
Φ6.35
Φ12.7
VP16
0.11
4.0
3,400
13,700
4.8
4,100
16,400
41-37-34
16
720/630/570
40
Φ6.35
Φ12.7
VP16
0.11
5.6
4,800
19,100
6.3
5,400
21,500
43-41-38
22
770/700/620
50
Φ6.35
Φ15.88
VP16
0.11
6.3
5,400
21,500
7.5
6,500
25,600
44-43-42
24
820/770/710
50
Φ6.35
Φ15.88
VP16
0.11
R410A(Nitrogen-charged for Corrosion-resistance)
Flare-nut Connection(with Flare Nuts)
Wall Mounting Bracket
WTHXEV28HHX WTHXEV45HHX WTHXEV56HHX WTHXEV63HHXAC1Φ 220 240V/50Hz~
Wall Mounted Type
The quality of “elegance” is additionally provided to meetcontemporary needs. Features a simple, smooth form thatharmonizes with any interior style.
Anti-mold filter is equipped as standard accessory.
Designed with ease of installation in mind, this new modeladopts a slim design and uses a high proportion of lightweightresin parts. Unit weight has been vastly reduced.
Uses the “Wonder Flap” in its air outlet. The flap, provided with threeflow guides each at its right and left sides, helps disperse the air flow.
throughout the room.
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB)
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
The sound pressure level is based on following conditions:
1.0m beneath the unit and 1.0m from inlet grille.
Voltage of the power source for the indoor fan motor is 220V.
In case of the power sourse of 240V, the sound pressure level increases by about 1 2dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
2.
~
38
Compact design for limited space inside of perimeter wall
So compact that it fits into even a tiny space
Cabinet Color
Refrigerant
Motor Power
Refrigerant Piping Connection
Condensate Drain
Approximate Packing
Measurement
Liquid Line
Gas Line
Net Weight
Outer Dimensions
(H x W x D)
Indoor Fan Air Flow Rate
(Cooling/Heating)
Nominal Heating
Capacity
Nominal Cooling
Capacity
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
dB(A)
mm
kg
m3/h
W
mm
mm
m3
Model
Power Supply
Indoor Unit Floor Concealed Type
Sound Pressure Level
(High/Medium/Low)
620 x 900 x 202 620 x 1170 x 202
2.8
2,400
9,600
3.3
2,800
11,300
34-31-27
18
510/450/380
50
Φ6.35
Φ12.7
VP25
0.19
4.3
3,700
14,700
4.9
4,200
16,700
40-36-34
22
620/540/480
80
Φ6.35
Φ12.7
VP25
0.19
5.6
4,800
19,100
6.5
5,600
22,200
41-36-32
26
890/740/630
90
Φ6.35
Φ15.88
VP25
0.23
7.1
6,100
24,200
8.5
7,300
29,000
44-40-36
27
980/830/710
120
Φ9.53
Φ15.88
VP25
0.23
R410A(Nitrogen-charged for Corrosion-resistance)
Flare-nut Connection(with Flare Nuts)
Silky White
FTHXEV28COHX FTHXEV43COHX FTHXEV56COHX FTHXEV71COHX
Floor Concealed Type
Special emphasis placed on interior design compatibility as well as space saving design,allowing it to fit perfectly into the space below a bay window. So compact that it fits into even a tiny space.
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB)
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
The sound pressure level is based on following conditions:
1.5m meters from the unit and 1.5m meters from floor level.
The above data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
2.
AC1Ф 220 240V
/50Hz~
39
Create comfortable and healthy indoor environment Flexible line-up to Fujitherma VRF Plus series
Higher external static pressure
Advanced control
(Only For M/R/G Series)
Nominal Capacity
Cooling Capacity
Heating Capacity
Power Input
Combined Outdoor Unit Model
kW
Btu/h
kW
Btu/h
kW
A
mm
mm
mm
dB
kg
m3/h
Pa
mm
mm
Model
Power Supply
Refrigerant
Indoor Fan Air Flow Rate
Drain Piping Size
Refrigerant Liquid
Line Size
Refrigerant Gas Line Size
Temperature Range of
Fresh Air Drawn
External Static Pressure
Sound Pressurd Level
Net Weight
Outer Dimensions
H
W
D
R410A
VP25,Outer Diameter: Φ32mm
Cooling: 20℃ 43℃,Heating: -7℃ 15℃
Fujitherma VRF Plus
14.0
47,800
13.7
46,800
370
1,320
800
43
60
1080
200
Φ9.53
DHTHXFA140HHX DHTHXFA224HHX DHTHXFA224HHX DHTHXFA280HHX DHTHXFA280HHXDHTHXFA90HHX
AC1Φ,220 240V/50Hz
0.33
1.45
22.4
76,500
21.9
74,700
486
1,270
1,069
45
97
1680
220
Φ9.53
Φ19.05
AC1Φ,220 240V/50Hz
0.49
2.25
28.0
95,600
24.5
83,600
486
1,270
1,069
46
97
2100
220
Φ9.53
Φ22.2
AC1Φ,220 240V/50Hz
0.51
2.35
AC1Φ,220 240V/50Hz
9.0
30,700
8.6
29,400
0.15
0.65
370
920
800
32
46
660
60(120)
Φ9.53
Φ15.88
0.61
2.79
0.71
3.25
AC1Φ,220V/60Hz
AC1Φ,220/60Hz
All Fresh Air Indoor Unit
Create a comfortable and healthy indoor environment by introducing fresh outdoor air. By heating or cooling fresh outdoor air to almost the same temperature as room temperature, fresh ambient air can be adapted and then introduced into indoor room. Besides, after filtered, fresh outdoor air in transition seasons can be drawn to indoor room directly with no need of heating or cooling operation, While fresh outdoor air is introduced, other indoor units don’t bear fresh air load.
All fresh air indoor unit is applicable to Fujitherma VRF Plusseries outdoor units. Both Fujitherma VRF Plus, series indoor units and all fresh air indoor units can be used in Fujitherma VRFPlus series system.
Can be interfaced to Hi-Dom system. Easy electrical wiring design and installation.Better installation flexibility at site, longer duct can be connected.
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions
Cooling operation conditions: 33℃ DB, 28℃ WB, piping length: 7.5m, piping lift: 0m
Heating operation conditions: 0℃ DB, -9℃ WB, piping length: 7.5m, piping lift: 0m
(Heating capacity is tested when defrosting is not available )
2.The sound pressure level is based on following conditions: 1.5 Meter beneath the unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the filed.
4.When the resistance of the filed-supplied duct is small, it may cause abnormal stop, malfunction, spraying water, etc.Due to excessive air flow. And the duct, which is to be connected to this unit, shall
be insulation for dew protection.
5.All fresh air indoor unit is for processing fresh air load and not for stabilizing the room temperature. For adjusting the air conditioning load of the room, the additional air conditioner is required.
6.This unit shall be connected to Fujitherma VRF Plus series outdoor units. In case of connecting this unit with other indoor units in the same refrigerant cycle,calculate t he capacity of this unit
as 46.1KBtu/h(30.7KBtu/h),71.7KBtu/h(47.8KBtu/h), 114.6KBtu/h(76.5KBtu/h), 143.3KBtu/h(95.6KBtu/h).
7.When VRF Plus outdoor unit connected to only with all fresh air indoor unit, the configuration rate is 100% (Recommended ).
8.Under cooling mode,when outdoor temperature is lower than 20℃,the system will automatically shift to ventilation operation; Under heating mode, when outdoor temperature is higher
than 15℃,the system will automatically shift to ventilation operation; In case inlet temperature is below -7℃,all fresh air unit will stop.
~ ~ ~
~ ~
40
Nominal Capacity
Cooling Capacity
Heating Capacity
Power Input
Combined Outdoor Unit Model
kW
Btu/h
kW
Btu/h
kW
A
mm
mm
mm
dB
kg
m3/h
Pa
mm
mm
mm
mm
33.5
114,300
26.8
91,500
486
1,270
1,069
56
97
3000
220
1,100×415
1,106×338
VP25,Outer Diameter: Φ32mm
Φ12.7
Φ25.4
45.0
153,600
36.0
122,900
635
1,950
805
61
196
4000
300
1,522×522
850×272
Φ12.7
Φ25.4
56.0
191,100
44.8
152,900
735
1,950
805
64
222
5000
320
1,522×622
850×272
Φ15.88
Φ28.6
56.0
191,100
44.8
152,900
735
1,950
805
66
222
6000
300
1,522×622
850×272
Φ15.88
Φ28.6
Model
Power Supply
Refrigerant
Indoor Fan Air Flow Rate
Drain Piping Size
Refrigerant Liquid
Line Size
Refrigerant Gas Line Size
Temperature Range of
Fresh Air Drawn
External Static Pressure
Air Inlet Size
Air Outlet Size
Sound Pressurd Level
Net Weight
Outer Dimensions
AC3Φ,380 415V/50Hz
R410A
RC1(Internal Screw)
Cooling: 20℃ 43℃,Heating: -7℃ 15℃
Fujitherma VRF Plus Series
AC3Φ,380 415V/50Hz
AC3Φ,380 415V/50Hz
AC3Φ,380 415V/50Hz
0.74
1.47
1.12
1.92
1.33
2.45
1.62
2.96
H
W
D
~ ~ ~ ~
~ ~
General Data for All Fresh Air Indoor Unit
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions
Cooling operation conditions: 33℃ DB, 28℃ WB, piping length: 7.5m, piping lift: 0m
Heating operation conditions: 0℃ DB, -9℃ WB, piping length: 7.5m, piping lift: 0m
(Heating capacity is tested when defrosting is not available )
2.The sound pressure level is based on following conditions: 1.5 Meter beneath the unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the filed.
4.When the resistance of the filed-supplied duct is small, it may cause abnormal stop, malfunction, spraying water, etc.Due to excessive air flow. And the duct, which is to be connected to this unit,
shall be insulation for dew protection.
5.All fresh air indoor unit is for processing fresh air load and not for stabilizing the room temperature. For adjusting the air conditioning load of the room, the additional air conditioner is required.
6.This unit shall be connected to Fujitherma,M and R series outdoor units. In case of connecting this unit with other indoor units in the same refrigerant cycle,calculate the capacity of this unit
as 46.1KBtu/h(30.7KBtu/h),71.7KBtu/h(47.8KBtu/h), 114.6KBtu/h(76.5KBtu/h), 143.3KBtu/h(95.6KBtu/h).
7.When Fujitherma outdoor unit connected to only with all fresh air indoor unit, the configuration rate is 100% (Recommended ).
8.Under cooling mode,when outdoor temperature is lower than 20℃,the system will automatically shift to ventilation operation; Under heating mode, when outdoor temperature is higher
than 15℃,the system will automatically shift to ventilation operation; In case inlet temperature is below -7℃,all fresh air unit will stop.
DHTHXFA335HHX DHTHXFA450HHX DHTHXFA560HHX DHTHXFA560HHX
41
Branch Pipe Parameter
Manifold Pipe Parameter
Receiver Kit for Wireless Control
Drain-up Mechanism Kit
Selection Software
Hotel Room Card Control
Branch Pipe Parameter
FHFQ-242FX
FHFQ-302FX
FHFQ-162FX
Q'ty : 1
Q'ty : 1
ID 9.53
OD 6.35
ID 9.53
OD 6.35
ID 9.53
OD 6.35
Q'ty : 1
Q'ty : 1
Q'ty : 1
Q'ty : 1
ID 25.4
ID 28.6
ID 22.2
ID 19.05
ID 15.88
ID 12.7
ID 28.6
ID 25.4
22.2
25.4
22.2
Ø
Ø
Ø
ID 25.4
ID 28.6
ID 22.2
ID 19.05
ID 15.88
ID 12.7
ID 28.6
ID 25.4
22.2
25.4
22.2
Ø
Ø
Ø
ID 12.7
ID 19.05 ID 22.2
ID 25.4 ID 15.88 OD 28.6
Q'ty : 1
ID 12.7
ID 19.05 ID 22.2
ID 25.4 ID 15.88 OD 28.6
ID 12.7
ID 19.05 ID 22.2
ID 25.4 ID 15.88 OD 28.6
ID 12.7
ID 12.7
ID 9.53
ID 6.35
ID 9.53
ID 12.7
12.7
9.53
9.53
Ø
Ø
Ø
ID 9.53
ID 12.7 ID 15.88
ID 15.88
ID 12.7
ID 9.53
ID 6.35
ID 15.88
ID 19.05
25.4
19.05
19.05
Ø
Ø
Ø
ID 32.0
ID 38.1
ID 28.6
ID 38.1
ID 32.0
31.75
31.75
28.6
Ø
Ø
Ø
ID 28.6
ID 22.2
ID 25.4
OD 31.75
Q'ty : 1 OD 38.1
ID 34.92
ID 9.53
ID 15.88
ID 19.05
ID 22.2
ID 12.7
ID 12.7
ID 15.88
ID 19.05
ID 22.2
ID 6.35
ID 9.53
25.4
22.22
19.05
Ø
Ø
Ø
FHFQ-102FX
ID 22.2
ID 19.05
ID 12.7
ID 15.88
ID 19.05
ID 22.2
ID 15.88
ID 15.88
ID 12.7
25.4
Ø 19.05
Ø 22.2
Ø
ID 9.53
ID 9.53
ID 6.35
ID 6.35
ID 9.53
12.7
9.53
9.53
Ø
Ø
Ø
Q'ty : 2
ID 9.53
OD 6.35
Model Gas Line Liquid Line Reducer for
Gas Line
Reducer for
Liquid Line
Opt
iona
l Par
tsO
ptio
nal P
arts
Optional Parts
42
HYRE-V01H HYRE-T01H NOTE
Receiver Kit for Wireless Control
Drain-up Mechanism Kit—Optional
FHYRE-V01HX is for Low/High Static Pressure Ceiling Ducted Type.
FHYRE-T01HX is for 4-Way Cassette Type.
Model Gas Line Liquid Line Reducer for
Gas Line
Reducer for
Liquid Line
Manifold Pipe Parameter
FHFQ-M22FX
FHFQ-M32FX
OD 31.75
OD 28.6
OD 38.1
ID 28.6 ID 25.4
ID 25.4
ID 34.92
ID 25.4
ID 22.2
ID 22.2
ID 22.2
ID 22.2
25.4 Ø
22.2 Ø
ID 22.2
ID 19.05
ID 19.05
ID 19.05
ID 15.88
ID 15.88
ID 15.88
ID 12.7 ID 12.7
ID 12.7
ID 15.88
ID 12.7 OD 28.6
ID 9.53
ID 9.53
ID 6.35
ID 19.05
19.05 Ø
ID 31.75
ID 38.1
ID 38.1
ID 32.0
ID 28.6
31.75 Ø
31.75 Ø
28.6 Ø
Q'ty : 1
Q'ty : 1
Q'ty : 1
ID 25.4
ID 28.6
ID 22.2
25.4
22.2
Ø
Ø
ID 19.05
ID 15.88
ID 12.7
ID 28.6
ID 25.4
22.2 Ø
ID 15.88 ID 15.88
ID 9.53
ID 12.7
ID 9.53
ID 6.35
25.4 Ø 19.05 Ø
19.05 Ø
ID 15.88
ID 12.7
Q'ty : 2
Model
FHPS-132X
FHPS-162X
FHPS-151X
Power supply
AC 220~240V(50/60Hz)
AC 220~240V(50/60Hz)
AC 220~240V(50/60Hz)
Consumption
9±1.5 W
9±1.5 W
9±1.5 W
MAX. Lift (mm)
900
900
600
Applicable models
For Ceiling ducted type(0.8~2.5Hp)
For Ceiling ducted type(3.0~6.0Hp)
External type,for general purpose(0.8~10Hp)
FHPS-132/HPS-162X FHPS-151X
43
Selection Software
With the philosophy of All for Users, Fujitherma developed a Central Air Conditioning Selection Software
which not only helps users to choose proper Fujitherma equipment but also to do the central air condition -
ing system design work.
This software makes the specialized central air conditioning project design work more simply and realistic
for nonspecialist. Whether you are a consultant or a sales people, you can work out a systematic piping
and wiring diagram with its user-friendly interface. Furthermore, a quick quotation of a project can be
provided with the selection of equipment and installation material.
Project information
Project information enteringChoose power supplyChoose temperature condition
Indoor unit selection
Room information enteringCooling and heating load calculationAutomatic & manual indoor unit selection
Outdoor unit selection
Choose connection ratioMatch indoor units and outdoor unitsAutomatic & manual outdoor unit selection
Capacity correction
enteringIndoor and outdoor unit correctionPoor capacity tips
Piping diagram
Automatic & manual outdoor and indoor unit pipe connectionBranch pipe selectionSegmental pipe length enteringAutomatic connection error tipsPipe size calculation
Wiring diagram
Power and communication cable connectionCable size calculationTerminals connectionController connection
Central control diagram
Central controller connectionBMS diagram
Reports output
Project information
Project information enteringChoose power supplyChoose temperature condition
Indoor unit selection
Room information enteringCooling and heating load calculationAutomatic & manual indoor unitselection
Outdoor unit selection
Choose connection ratioMatch indoor units and outdoor unitsAutomatic & manual outdoor unit selection
Capacity correction
enteringIndoor and outdoor unit correctionPoor capacity tips
Piping diagram
Automatic & manual outdoor and indoor unit pipe connectionBranch pipe selectionSegmental pipe length enteringAutomatic connection error tipsPipe size calculation
Wiring diagram
Power and communicationcable connectionCable size calculationTerminals connectionController connection
Central control diagram
Central controller connectionBMS diagram
Reports output
44
Hotel Room Card Control- Optional
The selection software operation interface
It is very simple to connect the units by the selection software . Users and designers can see
the relative position and connection mode between outdoor units and indoor units clearly .
Though the report given by the software we can get much more details ,indoor and outdoor
units specifications ,material list ,piping diagram ,wiring diagram and central-control diagram.
which will be very helpful to the budgeting and installation .
The "Room Card Control Function" of Fujitherma VRF
indoor unit through the room card.
When under function, the AC system is powered on.
The room card can control whether the room
energy-saving by withdrawing the room card when
people leave.
Hotel Room Card Control Room card