Continuous Particulate Monitoring
Using Light ScatterPhotometers
EPA Designation: None PM2.5 Continuous Particulate Monitor for AQI, Visibility, Remediation, Mobile Monitor Indoor Air Quality Monitor for Workplace, Home Casinos.Principle of Operation: Near Forward Light ScatterCost: Hand Held $3,000. Environmental for Outdoors $5,000.Accessories: Various PM Inlets, Filter and Foam InsertsDownloading: RS232 and Data SoftwareSupport: BGI Offices in Atlanta & Boston. USA DistributorsCalibration Procedure: HEPA Filter –Zero Reference Reference Filter- Span Calibration Dynamic Dust introduced in Lab Gravimetric Filter Comparison in FieldVerification: Flowrate, Zero, Span, Gravimetric Site CalibrationMaintenance: Lenses – Continuous Purge Air, Recal Daily Pump 1year Battery 2 years
Scattered light has components of diffraction, refraction and reflection.
Changes in the particulate reflective properties, shape
and color have an effect on instruments mass response. Gravimetric calibration is necessary to correlate to EPA
PM concentration criteria. Not EPA Designated. Used as a Survey or low cost continuous ambient monitor.
Diffracted
RefractedReflected
Small Detection
Angle
(Optical) Light Scatter Photometer Principle
Light Scattered by angle ß is measured.
IR Light Source
Photo-Detector
Light Traps
ß
SensingVolume
Microdust Photometer Design
Infra RedEmitter (880nm)
Infra RedDetector
Light Stop
FocusingLens
FocusingOptics
Sample Volume
Clean Air Condition. (No Particles)
Infra red beam is focused onto the light trap.
No forward scattering effect.
Zero mass measurement seen by detector.
Zero calibration using a HEPA filter.
Particulate Introduced to Sample Volume
Beam is scattered due to the effects of diffraction, refraction and reflection.
Intensity of Infra red signal is measured by detector and directly proportional to mass.
Particulate
Gravimetric & Respirable Adapters
* Size Selective Inlets
* Poly-Urethane Foam Plug Separators
* Adapter for use with all commercial FRM Samplers
Features
• Full measurement range 0.001 to 2500 mg/m3
• No EPA Approval. User correlated to gravimetric sample.
• Improved optics and zero drift electronics
• DC Battery 30 hour Battery or AC Operated
• Scrolling display/graph of particulate concentration
• 4 user defined calibrations
• Inlets for PM10 PM2.5 PM1 and TSP
•Low cost
•Hand held or Environmental enclosure
Microdust Ambient PM Environmental Enclosure
• Omni Directional Inlet
•Silent Operation
•Portable
•12 Volt DC
•Data Logger
•RS232 and Software
Ambient Continuous Monitor
PM Inlet Flow Controlled Pump Purge Air Microdust Monitor 12 Volt Battery Data Logging Software and Report
Applications
Work place and indoor monitoring. Ambient air quality monitoring for 24 hour continuous
particulate concentration Visibility and AQI Studies Casino Air Quality Ambient Continuous PM Survey and Site Sampler Roadside Monitor Portable DC or Solar Powered Prescribed Burns Emergency Response Remediation Monitor
Model PM950 for Continuous Ambient Monitoring
Auto Zero & Span
Auto Ranging
EPA PM10 FRM Inlet
VSCC Cyclone Inlet for PM2.5
Sample Flow of 16.67aLpm
Rh Controller
47mm FRM Filter
FRM Electronics and Data Logger
PM 950 Continuous Monitor
Summary
Proven continuous monitor technology
Comparable to gravimetric sampling
Detachable probe provides added versatility for
hand-held applications
Wide measurement range with consistent
results
Price and performance competitive
BGI Instruments
Contact us at –
58 Guinan Street
Waltham, MA 02451
Telephone (781) 891-9380
Fax (781) 891-8151