Shimaden, Temperature and Humidity Control Specialists
Series MR13
SHIMADEN DIGITAL CONTROLLER
°C
%RH
3-channel controller, 3-channel input, 3-channel setting and
simultaneous 3-channel display are possible
Accuracy: ± (0.3% FS + 1 digit)
Follow-up type PV input function
Follow-up type SV setting function
Remote/local and DI input function
Programmable 1 pattern with 9-step function
Included a new processing system, Expert PID, remarkably
improved PID control efficiency; overshoot and undershoot
are controlled effectively.
Interface RS232C/RS485
BASIC FEATURES
approved
Front Panel Information
Application Example
As the controller is capable of 3-channel input and setting,it is most suitable for zone control.Control of three points is possible by a single controllerusing three sensors. PV values of three points aredisplayed simultaneously. The use for zone control such asthe upper, middle and lower stages of a batch furnace andthe inlet, center and outlet of a tunnel furnace, and for heatcontrol of plastic molds, packing, machines and so forthare highly recommendable.
Follow-up Type PV Input Function
PV input of CH2 and CH3 can be linked to CH1 input. This function enables the controller to be used for 1-input 2-setting or 1-input 3-setting control.
• Multistage control of heating/cooling • Control of heating/cooling and humidification/dehumidification
Follow-up Type SV Setting Function
As it is possible to make CH2 and CH3 set values follow that of CH1, SVs of these channels can be changed simplyby changing CH1 setting.This function is conveniently made use of when temperature levels multiple points are changed or multipleprogramming functions are used.
Use of Expert PID Reduces Overshoot
Higher controllability has been attainted by the useof expert PID which can suppress hunting byovershoot or disturbance.
Series MR13MR13 SERIES 3-CHANNEL CONTROLLER
MR13
PV 1
PV 2
PV 3
SVCH
AT
FLW
REM
COM
RUN
OUT1 EV1
OUT2
OUT3
EV2
EV3
PV1 display
PV2 display
PV3 display
Key switches
SV displaySV channel display
Action displayLEDs
7
1
2
3
4
6
5
TC2 TC1 TC3
PACthyristor
PACthyristor
PACthyristor
Electric Furnace
Heater
T
Room
F
Air conditioner
CH1
MR13
CH2
CH3PAC15
PAC15
Heat
Cool
TH
Room
F
Air conditioner
CH1
MR13
CH2
CH3
converter
Heat
Cool
T
H
PID control by new operatingmethod (Expert PID)
Shimaden's previousPID control
DisturbanceDisturbance
SV
PV
SV
PV
t t
Programming Function
With the addition of the programming control function, it has become possible to carry out zone control of furnaces forchina, ceramics, etc., which can be made in an ascending pattern of one pattern with nine steps maximum.
* Program control of 1 pattern with 9 steps maximum
* Step execution time: 1-9999 minutes* The number of executions: 1-9999 times* Either PV start or SV start selectable* The temporary stop (HLD) function and
the step forward (ADV) function are include.
* A program ramp is automatically determined by selecting the temperature and time for each step.* In the MR13, only CH1 is equipped with the programming function. In case CH2 and CH3 are used for program
control, follow-up type SV should be set for each of them.
Remote and DI Input Functions
* The remote or DI input function can be added.
a. DI setting allows the controller to operate in response to an external control (non-voltage contact or open collector)signal.
* RUN/RST (during program control)* HLD (during program control)* ADV (during program control)
b. Remote setting of an SV value by means of an external analog signal is possible as per the below drawing nos.1and 2.
c. Simple cascade control by remote setting
* When CH1 control output is made remote SV of CH2, a single MR13 controller can carry out cascade control.* Select control output (OUT) from CH1 transmission
signals (SV, PV and OUT) and input it to the remoteterminal of CH2 instead of inputting the control outputdirectly to the remote SV of CH2.This raises the resolution of CH1 control output sothat control characteristics can be improved.
Event Function
* Three points are available for event outputs.* Event output selected from the list of Events shown on page 6 can be assigned to EV1, EV2 and EV3.
Communication Function
For the MR13 series controllers, there are two types of communication interface, RS232C and RS485. Each allows apersonal computer, etc., to set and read data of the MR13 series using signals based on EIA standards.
Series MR13ADDITIONAL FUNCTIONS (OPTIONAL)
No.1
Drawing No.1
No.2 No.3T T T
CH1
MR13 REM1.
REM2.
REM3.CH2
CH3
CH1
CH2
CH3
T1T3 T2
EMMD CP2
EM
AL
REM
Analog out
OUT
Drawing No.2
1 2
5 6
7
175˚CS5, 6125˚C
S7
75˚CS1, 225˚CS-SV
STEP1t-1
STEP2t-2
STEP6t-6
STEP7t-7
Series MR13
Display• LED display: PV display 7-segment LED green 4
digits 3 channels to be displayed individually.SV display 7-segment LED orange 4 digits CH display 7-segment LED orange 1 digit
• Action display LED: Control output display: 3 - OUT1, OUT2, OUT3 Auto tuning: 1 - ATFollow type SV display: 1 - FLW Program RUN: 1 - RUNEvent output display: 3 - EV1, EV2, EV3 Remote input display: 1 - REMCommunication display: 1 - COM
• Display accuracy: ±(0.3%FS + 1 digit) Standard accuracy
• Temperature range in which accuracy is maintained: 23°C±5°C
• Display resolution: Depends on measuring range(0.001, 0.01, 0.1, 1)
• Sampling cycle: 0.5 seconds • Measured value
display range: –10% to 110% of measuring range
Setting• Setting: By 6 front key operation• Setting range: Same as measuring range• Higher/lower limit
setting limiter: Higher and lower limits to be set separately; free within measuring range (Lower limit < higher limit)
• Follow type SV setting: SV of CH2 or CH3 can be set to follow CH1 (deviation setting) (on condition that measuring range of CH2 or CH3 is the same as that of CH1.)
Input• Input type has to be the same for 3 channels (measuring range
can be selected individually).• Thermocouple: B, R, S, K, E, J, T, N, PL II, WRe5-26,
L, U (DIN43710)(Multiple input, multiple range. Refer to measuring range code table.)
External resistance: 100Ω maximumInput impedance: 500kΩ minimumBurnout: Standard feature (up scale)Cold junction temperature compensation accuracy: ±2.0 °C (5~45 °C)
• R.T.D.: JIS Pt100/JPt100 3-wire type (Multiple range. Refer to measuring range code table.)
Amperage: Approx. 0.25 mALead wire tolerable resistance: 5Ω maximum/wire
• Voltage: ±10, 0~10, 0~20, 0~50, 10~50, 0~100mV DC, or ±1, 0~1, 0~2, 0~5, 1~5, 0~10V DC (Multiple input, programmable range.Refer to measuring range code table.)
Input impedance: 500kΩ minimum• Current: 4~20, 0~20mA DC
(Multiple input, programmable range.Refer to measuring range code table.)
Receiving impedance: 250Ω
• Sampling cycle: 0.5 seconds• PV bias ±1999 units• PV filter: OFF, 1~100 seconds• Follow type PV input: PV input of CH2 or CH3 can be set
to follow CH1 (deviation setting) (on condition that measuring range of CH2 or CH3 is the same as that of CH1.)
• Isolation: Insulated between input and various outputs (not insulated between input and system, remote input and DI input)
Control• Control mode: Expert PID control with auto tuning
functionProportional band (P): OFF, 0.1~999.9%FS
(OFF=ON/OFF action)Integral time (I): OFF, 1~6000s (OFF=P, PD action
with manual reset)Derivative time (D): OFF, 1~3600s (OFF=P, PI action)Manual reset: ±50.0%ON/OFF hysteresis: 1~999 units
• Proportional cycle: 0.5~120.0 seconds(0.5 sec. is unit for setting.)
• Control output characteristics: RA/DA selectable (set to RA when
shipped)• Output limiter: Higher limit, lower limit 0.0~100.0%
(lower limit < Higher limit)• Soft start: OFF, ON (Fixed to 10 sec.; Valid
when power is turned on, RTS RUN, and when returned from scaleover.)
Control output/rating• Output specification has to be the same for 3 channels.• Contact output (Y): 1a 240V AC 2.5A/resistive load• Current output (I): 4~20mA, 0~10mA DC/
load resistance 600Ω maximum.• SSR drive voltage
output (P): 15V±3V DC/Load current 20mA maximum
• Voltage output (V): 0~10V DC/Load current 2mA maximum
• Operation output updating cycle: 0.5 second
• Isolation: Insulated between control output and system and input(not insulated between control output I, P or V and analog output)
Event output (optional)• Number of outputs: 3 -EV1, EV2, EV3 (Selectable from
CH1, CH2 and CH3, individual setting, individual output)
• Output rating: Contact output 1a (common) 240V AC / 1A (resistive load)
• Setting: Individual setting0) NON: Not assigned1) DEV: Higher limit deviation value
alarm2) DEV: Lower limit deviation value
alarm3) DEV: Higher/lower limit value
alarm in case SV is out of measuring range
4) DEV: Higher/lower limit value alarm in case SV is within measuring range
5) PV: Higher limit absolute value alarm
6) PV: Lower limit absolute value alarm
7) SO: ON upon scaleover8) RUN: ON during program RUN9) END: ON for 1 sec. upon
termination of program10) STEP: ON for 1 sec. upon
termination of program step• Hysteresis: 1~999 units
(when DEV or PV has been selected)• Standby action: Selectable
(when DEV or PV has been selected) • Action delay time: OFF, 1~9999 seconds
(when DEV or PV has been selected)• Isolation: Insulated between alarm output and
various inputs/outputs and system
SPECIFICATIONS
Remote setting (optional, selectable between this function and DI)• Setting signal: 1~5V, 0~10V, 4~20mA• Setting range: Same as measuring range• Accuracy of setting: ±(0.3%FS + 1) digit• Channel for setting: Selectable from CH1, CH2 and CH3• Remote scaling: Within measuring range (inverted
scaling possible)• Remote bias: –1999~5000 units• Remote filter: OFF, 1~100 seconds• Sampling time: 0.5 second• Isolation: Insulated between remote input and
various outputs (not insulated from system and various inputs)
External control input (DI) (optional, selectable between thisfunction and remote setting)• Number of input point: 1• Input rating: Non-voltage contact, open collector
input (about 5V/0.4mA DC impress)• Action type: NON, FLW (follow type SV), RST/
RUN, HLD and ADV• Isolation: Insulated between DI input and
various outputs (not insulated from system and various inputs)
Program (optional)• Registrable pattern: 1• Number of steps: 9 maximum• Program setting range
Level: Same as measuring rangeTime: 1~9999 minutes/stepRamp: To be set automatically according to
level and time• Number of executions: 9999 maximum• PID output limiter: To be set selectively from 3 types of
PID & output limiter• External control input: DI/non-voltage 1 point (RUN/RST,
HLD, ADV)• Action status output: RUN, END and STEP to be
selectively output to event output• CH2 and CH3 in
SV follow setting: Program to be executed by making CH2 or CH3 deviation-follow to pattern set in CH1 in SV follow setting. Not in SV follow setting, program is executed in FIX mode.
• Additional functions: Temporary suspension (HLD), carry-forward (ADV), PV start
Analog output (optional, selectable between this function andcommunication)• Number of output: 1• Output types: Selectable from CH1_PV, CH2_PV,
CH3_PV, CH1_SV, CH2_SV, CH3_SV, CH1_OUT, CH2_OUT and CH3_OUT
• Output rating: 0~10mV DC/Output impedance 10Ω
0~10V DC/Load current 1mAmaximum4~20mA DC/Load resistance 300Ω
maximum• Output accuracy: ±0.3%FS (to displayed value) • Output resolution: Approx. 1/8000 • Output updating cycle: 0.5 seconds• Output scaling: Within measuring range (inverted
scaling possible)• Isolation: Insulated between analog output and
various inputs and system (not insulated between analog output and control outputs I, P and V)
Communication (optional, selectable between this function andanalog output)• Communication type: RS-232C, RS-485• Communication system: Half duplex start-stop synchronous
system• Communication speed: 1200, 2400, 4800, 9600, 19200bps• Data format: 7 bits, 8 bits, no parity, even parity
selectable
• Communicationaddress: 1~99
• Communication code: ASCII code• Communication
protocol: Shimaden standard protocol• Communication format: Control code selectable, BCC check
arithmetic system selectable• Isolation: Insulated between communication
signal and system/input/output • Others: Meets the EMC standards with an
additional clamp filter (E04SR301334, SEIWA Information Systems Co.,LTD)
Others• Data storage: By non-volatile memory (EEPROM)• Ambient temperate/
humidity ranges: -10~+50°C/below 90% RH(on condition that there is no dew condensation)
• Temperaturefor storage: Between-20 and +65 °C
• Power voltage: 100V~260V AC ±10% (50/60 Hz)• Power consumption: 18VA maximum• Input noise
removal ratio: Normal mode 45 dB minimum(50/60 Hz)Common mode 140 dB minimum(50/60 Hz)
• Applicable standardSafety: IEC1010-1 and EN61010-1EMC: EN61326
• Insulation resistance: Between input/output terminals and power terminal: 500V DC 20MΩ
minimumBetween input/output terminals and protective conductor terminal: 500V DC 20MΩ minimum
• Dielectric strength: 1 minute at 2300V AC between input/output terminals and power terminal (inductive current 5mA) 1 minute at 2300V AC between power terminal and ground terminal(inductive current 5mA)
• Protective structure: Only front panel has simple dust-proof and drip-proof structure
• Material: PPO resin molding (equivalent to UL94V-1)
• External dimensions: 96 x 96 x 110 mm(Panel depth: 100 mm)
• Mounting: Push-in panel (one-touch mount)• Panel cutout size: H92 x W92 mm• Weight: Approx. 420 g
Series MR13SPECIFICATIONS
ITEMS CODE SPECIFICATIONS
SERIES MR13- MPU-Based 3 Channel Auto-Tuning PID Controller DIN 96 × 96mm
1Thermocouple B, R, S, K, E, J, T, N, PLII, Multi-input
WRe5-26, U, L Multi-range
2 R.T.D. Pt100 / JPt100 Multi-range
INPUT3
Voltage (mV) -10-10, 0-10, 0-20, 0-50, 10-50, Multi-input
0-100mV DCProgrammable
4 Current (mA) 0-20, 4-20mA DCRange
6 Voltage (V) -1-1, 0-1, 0-2, 0-5, 1-5, 0-10V DC
Y1-Contact: Proportional Cycle 0.5-120.0 sec.
Contact capacity: 240V AC 2.5A / resistive load
I1-Current: 4-20, 0-10mA DC
CONTROL OUTPUTLoad resistance: 600Ω max.
P1-SSR drive voltage: Proportional Cycle 0.5-120.0 sec.
Output rating: 15V±3V DC / 20mA max.
V1-Voltage: 0-10V DC
Load current: 2mA max.
PROGRAM FUNCTION (OPTION)N None
P 1 Pattern, 9 step
0 None
EVENT OUTPUT (OPTION)1
Contact (1a common): 240V AC 1A / resistive load EV1, EV2,
EV3 / 3 Point
00 None
04 4-20mA DC Receiving resistance: 250Ω
REMOTE OR DI INPUT (OPTION) 05 1-5V DC Input resistance: 500kΩ min.
06 0-10V DC Input resistance: 500kΩ min.
51 DI Non-Voltage Contact, Open Collector Input
00 None
03 Voltage 0-10mV DC, Output resistance: 10Ω
ANALOG OUTPUT OR 04 Current 4-20mA DC, Load resistance: 300Ω max.
COMMUNICATION FUNCTION (OPTION) 06 Voltage 0-10V DC, Load current: 1mA max.
15 RS-485
17 RS-232C
REMARKS0 Without
9 With (Please consult before ordering.)
TYPES OF EVENTS
Event type code table
Code Event type
Not assigned
Higher limit deviation value
Lower limit deviation value
Out of higher/lower limit ranges
Within higher/lower limit ranges
Higher limit absolute value
Lower limit absolute value
Setting range of event set value
Initial value of event set value
0~1999 Unit
0~–1999 Unit
0~1999 Unit
0~1999 Unit
1999 Unit
–1999 Unit
1999 Unit
1999 Unit
Within measuring range
Within measuring range
Higher limit value of measuringrange Lower limit valueof measuringrange
OFF
1
2
3
4
5
6
Code Event type
Scale-over
Program RUN
Setting range of event set value
Initial value of event set value
In the case of scale-over, EV output is continued.
EV output is continued whileprogram is in execution.
Program END EV output is produced for about 1 second upon termination of program.
Program STEP EV output is produced for about 1 second upon switching steps.
7
8
9
10
Note: The above codes from 8 to 10 are selectable only whenprogram option is added.
ORDERING INFORMATION Series MR13
Series MR13
EXTERNAL DIMENSIONS
13
0 m
in
130 min
92+0.8 0
92
+0
.8
0
110
10010
91.6
91
.6
222
211 1131
1232
1333
1434
1535
1636
1737
1838
1939
2040
23
244
255
3
26
277
6
9
28
29
8
3010
ENTDISP CH
MR13
OUT 3 EV 3
OUT 2 EV 2
OUT 1 EV 1
RUN
FLW COM
AT REM
CH
PV 3
PV 2
PV 1
SV
96
96
MEASURING RANGE CODES
01 15
16
17
18
19
20
21
22
23
24
25
26
27
28
02
03
04
05
06
07
08
09
10
11
12
14
31
32
33
34
35
36
37
38
47
48
49
50
51
52
53
54
39
40
41
42
43
44
45
46
55
56
57
58
59
60
61
62
Code CodeMeasuring range Measuring range
0
0.0
0
0
0
-199.9
-199.9
-200
0
0
0
0
0
0
-100.0 400.0
800.0
200.0
200.0
-100.0
-100.0 300.0
-50.0 50.0
-200 500
-100.0 100.0
-100.0 300.0
-50.0 50.0
0.0
0.0
0.0
0.0
100.0
100.0
200.0
500.0
50.0
1700
1200
1300
1300
2300
700
600
600
600
1700
1800
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
13 °C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
0
0
0
0
0
-300
-300
0
0
0
0
0
0
-150 750
1500
400
400
200.0
3100
2200
2300
2300
4200
1300
1100
1100
3100
3300
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F
°F-300 1100
600
°F-150.0
°F-150
120.0 °F-50.0
120.0 °F0.0
200.0 °F0.0
400.0 °F0.0
1000 °F
°F
°F
°F
°F
°F
°F
°F
°F
0
900-300
200.0-150.0
*3
*3 0.0 50.0
0.0 100.0
0.0 200.0
0.0 500.0
600-150
120.0-50.0
120.00.0
200.00.0
400.00.0
9000
B
R
S
K
E
J
T
N
PLII
WRe5-26
U
L
*2
*2
*1
Pt100(New)
JIS/IEC
JPt100(Old)JIS
Input type
Therm
ocouple
R.T
.D.
71
72
73
74
75
76
81
82
83
84
85
86
94
95
Code Measuring range
mV
V
mA
-10 10
10
20
50
50
100
0
0
0
10
0
-1 1
1
2
5
5
10
0
0
0
1
0
200
204
Input type
Depending on scaling function, you may set measuring range at any value within the following range: Scaling range: –1999~9999 count Span: 10~5000 countNote: Lower limit value < Higher limit value
InputStandard/
rating CodeMeasuring
range
1. Thermocouple
2. R.T.D.
3. Voltage
4. Current
5. Voltage
JIS K
JIS Pt100
0 10mV DC
4 20mA DC
0 10V DC
05
37
72
95
86
0.0 800.0°C
0.0 200.0°C
0.0 100.0
0.0 100.0
0.0 100.0
Panel Cutout
(Unit : mm)
*1 Thermocouple B: Temperature above 400°C or below 750 °Fis excluded from accuracy assurance.
*2 Thermocouple T, U: Accuracy of temperature between -199.9and 100.0°C is ±0.5% FS.
*3 R.T.D.: Accuracy is ±0.3°C (±0.8 °F).
The following table shows factory-set measuring range codes:
1 1 21 21 31 1111
2 2 22 22 32 1212
3 3 23 23 33 1313
4 4 24 24 34 1414
5 5 25 25 35 1515
6 6 26 26 36 1616
7 7 27 27 37 1717
8 8 28 28 38 1818
9 9 29 29 39 1919
10 10 30 30 40 2020
15
16
15
16
+
—
21
22
21
22
+
—
11
13
12
CH1
17
18
17
18
+
—
CH2
19
20
19
20
+
—
CH3
I. V. OutputSSR. drive.V Output
100-260V AC~50/60Hz 18VA
GND
Contact Output
A-output RS-232C RS-485
Control Output
Power SupplyDIREM
23
24
SG
SD
25RD
23
24
SG
+
25—
23+
24—
Analog Out • Com
27
28
29
30
COM
EV1
EV2
EV3
Event Output
I.V. Input TC Input RTD Input
2
4
2
3
A
B
4B
+
—
+
—
2
4
5
7
5
6
A
B
7B
+
—
+
—
5
7
8
10
8
9
A
B
10B
+
—
+
—
8
10
INPUT
Series MR13TERMINAL ARRANGEMENT
ISO 9001
(The contents of this brochure are subject to change without notice.)
Temperature and Humidity Control Specialists
Head Office: 2-30-10 Kitamachi, Nerima-Ku, Tokyo 179-0081 JapanPhone: +81-3-3931-7891 Fax: +81-3-3931-3089
E-MAIL: [email protected] URL: http://www.shimaden.co.jp
00IMR13 1030
Warning
• The MR13 series is designed for the control of temperature, humidity and other physical values of general industrial
equipment. (It is not to be used for any purpose which regulates the prevention of serious effects on human life or safety.)
Caution
• If the possibility of loss or damage to your system or property as a result of failure of any part of the process exists, proper
safety measures must be made before the instrument is put into use so as to prevent the occurrence of trouble.
TERMINAL COVER (AVAILABLE SEPARATELY)
Mounting: 2+B tight pan-head screwsM2.3x6mmModel
MR13
Material/ Appearance: PVC/ transparentThickness: 1mm
SR5301-9
Series SR1 / SR3
SHIMADEN DIGITAL CONTROLLER
C
%RH
INPUT
ORDERING INFORMATION
BASIC FEATURES
MEASURING RANGE CODES
01
02
03
04
05
06
07
08
09
10
11
12
14
31
32
33
34
35
36
37
38
Code Scaling range
13*3
B
R
S
K
E
J
T
N
PLII
U
L *2
*3
*4
*5
*3
*2,
*1
Pt100
JPt100
Type of input
Th
erm
oco
up
leR
.T.D
.
Vo
lta
ge
71
72
73
74
75
76
81
82
83
84
85
86
Scaling range
(mV)
Vo
lta
ge
(V)
10 10
10
20
50
50
100
0
0
0
10
0
1 1
1
2
5
5
10
0
0
0
1
0
Type of input
Optional setting of Measuring range is possible by the scaling function as shown below.
Scaling range: 1999~9999 countSpan: 10~5000 countLower limit value < Upper limit valuePosition of decimal point : None : Decimal point below digits, 1, 2, 3
Code
0
0.0
0
0
0
200
200
0
0
0
0
0
0
100.0
50.0
0.0
0.0
199.9
199.9
199.9
100.0
50.0
400.0
800.0
200.0
200.0
50.0
200.0
100.0
1700
1200
1300
1300
2300
700
600
600
600
1700
1800
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
50.0
200.0
100.0
500
C
C
C
C
0
0
0
0
0
300
300
0
0
0
0
0
0
150.0
50.0
0.0
0.0
300
300
300
150.0
50.0
750
1500
400
400
120.0
400.0
200.0
3100
2200
2300
2300
4200
1300
1100
1100
1100
3100
3300
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
120.0
400.0
200.0
1000
F
F
F
F
WRe5-26
Note:*1 Thermocouple B: Accuracy guarantee not applicable Temp. below 400 C.*2 Thermocouple U, L: DIN 43710*3 Thermocouple K, T, U: Accuracy guarantee not applicable Temp.
below –100.0 C (1.0%FS+1digit) & –100.0 0.0 C (0.5%FS+1digit)*4 Thermocouple PLII: Platinel*5 Thermocouple WRe5-26: ASTM988
Input Specification/Rating Measuring range
Multi input
Voltage (V)
K thermocouple
0 10V DC
0.0 800.0 C
0.0 100.0
*Unless otherwise specified, following setting will be applied for shipment.
approved UL approved (except SR4)
Series SR1 / SR3 / SR4
Multi-input and multi-range
performance
SHIMADEN DIGITAL CONTROLLER
˚C
%RH
Y ON-OFF
Control ModeControl Output
I, P, V PID Control (P=3.0)
(P=OFF)
ITEM CODE SPECIFICATIONS
SERIES
SR1 MPU-Based Auto-Tuning PID Digital Controller, DIN H48 x W48 x D111mm
MPU-Based Auto-Tuning PID Digital Controller, DIN H96 x W96 x D111mmSR3
8 Multi input
Thermocouple: B, R, S, K, E, J, T, N, PLII, WRe5-26 U, L (DIN 43710)
-10~10, 0~10, 0~20,Scaling possible
Span: 10~5000
Range: -1999~99990~20mA DC:(V) 0~5V DC
(applied via enclosed 250Ω shunt resistor)
0~50, 10~50, 0~100mV DCVoltage(mV):
Contact 1a Contact capacity: 240V AC 2.0A/resistive load Proportional cycle: 1~120 seconds
Current 4~20mA DC Load Resistance: 600Ω max.
Voltage 0~10V DC Load current: 2mA max.
With (Please consult before ordering.)
Without
Event output (1a) x 2 points, Contact capacity: 240V AC 1A/resistive load
SSR drive voltage 12V ±1.5V DC 30mA max. Proportional cycle:1~120 seconds
Current (mA): 4~20mA DC:(V) 1~5V DC
Voltage (V): -1~1, 0~1, 0~2, 0~5, 1~5, 0~10V DC
R.T.D.: Pt100/JPt100
6
Y
CONTROL OUTPUTI
P
V
EVENT OUTPUT 1
REMARKSW
X
Shimaden, Temperature and Humidity Control Specialists
Large 20mm bright display (SR3)
Dust and splash proof front panel
NEMA4X / IP66
MPU-Based Auto-Tuning PID Digital Controller, DIN H96 x W48 x D111mmSR4
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
°
° ± ±°
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
Terminal Arrangement
Unit: mm
1 6
I.
I.
7
8
9
10
2
3
4
5
OUTPUT4-20mA DC0-10V DC30mA12V DC2A 240V AC
100-240V AC50/60Hz10VA
DC
+ +
+
A
B
B
COMEV11A240V AC
EV21A240V AC
L
N
100-240VAC50/60Hz 10VA
OUTPUT4-20mA DC0-10V DC30mA12VDC2A240V AC
1
2
3
4
5
6
7
8
9
10DC
+ + A
B
B
COMEV1
1A240V AC
EV21A240VAC
+
L
N
ISO 9001 ISO 14001
(The contents of this brochure are subject to change without notice.)
Temperature and Humidity Control Specialists
Head Office: 2-30-10 Kitamachi, Nerima-Ku, Tokyo 179-0081 JapanPhone: +81-3-3931-7891 Fax: +81-3-3931-3089
E-MAIL: [email protected] URL: http://www.shimaden.co.jp
Warning • The SR1 / SR3 / SR4 series are designed for the control of temperature, humidity and other physical values for the general industrialequipment. It is not to be used for any purpose which regulates the prevention of serious effects on human life or safety. No warranty, express or implied is valid if used without proper safety measures.
Caution • If the possibility of loss or damage to your system or property as a result of failure of any part of the process exists, proper safety measures must be made before the instrument is put into use as to prevent the occurrence of trouble.
Material:PVC, Appearance:transparent, Thickness: 1 mm
SR1
SR3
SR4
QCR001
QCR006
QCR004 (Individual Mounting)
QCR005 (Tight-lock coupling)
One-touch mount
One-touch mount
Plus screw, B tight, M2.3 x 6 - 2 pcs.
Plus screw, B tight, M2.3 x 6 - 4 pcs.
Model Terminal Cover (P/N) MountingTERMINAL COVER (AVAILABLE SEPARATELY)
SR1 SR3 / SR4
Series SR1 / SR3 / SR4
ENT
Model SR1: SR3:
Display Digital display:SR1, SR4:
SR3:
Display accuracy:
Display accuracy maintaining range:
Display resolution: Display updating cycle: Action display:Setting Setting method:Target value setting range:
Setting limiter:
InputType of input:
Thermocouple: Input impedance: External resistance tolerance:
Burnout function: Cold junction compensation accuracy:
R.T.D.: Amperage: Lead wire tolerance:
Voltage mV: (Burnout)
V: Input impedance:
Input scaling function: Scaling range:
Span: Decimal point:
Sampling cycle: PV bias: PV filter: Isolation:
Control Control mode:Proportional band (P):
Integral time (I): Derivative time (D):
Manual reset: ON-OFF hysteresis: Proportional cycle:
Control output characteristic:
Type of control/rating: Contact: SSR drive voltage:
Voltage: Current:
Control output resolution: Isolation:Event outputNumber of events:Type:
Event setting range:
Event action: Hysteresis: Standby action:
(EV1 and EV2)
Output type/rating: Output updating cycle: Action display:General Specifications Data storage: Operating conditions:
Storage temperature: Supply voltage: Power consumption: Input/noise
removal ratio:
Applicable standards:
Insulation resistance:
Dielectric strength:
Protective structure:
Material / Color of case: External dimensions:
Mounting: Panel thickness: Panel cutout / Weight:
RA (reverse action characteristic)/DA (direct actioncharacteristic) is selectable (Default setting =RA) *P=OFF by default for contact output, others: PID control
1a 240V AC 2A (resistive load)12V ±1.5V DC (Max load current 30mA)0~10V DC (Max load current 2mA)4~20mA DC (Max load resistance 600Ω )Approx.0.5%(1/200)Output isolated from all
Total 2 points of EV1 and EV2 as standardSelectable from the following 8 types for EV1 and EV2:No selection, Higher limit deviation, Lower limit deviation,Outside higher/lower limit deviations, Withinhigher/lower limit deviations, Higher limit absolute value,Lower limit absolute value, ScaleoverAbsolute values: (both higher limit and lower limit): Withinmeasuring range, Deviations: (both higher limit and lower limit): -1999~2000 units, Higher/lower limitdeviations (within/outside): 0~2000 unitsON-OFF action1~999 unitsSelectable from the following 4 types(1) None. (2) Standby when power is applied. (3) Standbywhen power is applied and when SV value in executionis changed. (4) Control mode without standby action(No alarm is output at the time of abnormal input).Contact (1a x 2 points common)/240V AC 1A (resistive load)0.5 seconds2 LED lamp displays (EV1/EV2)
Non-volatile memory (EEPROM)(Ambient temperature) -10~50 ˚C(Ambient humidity) 90%RH or less (no dew condensation)(Altitude) 2000m from the sea level or lower(Category) II, (Degree of pollution) 2-20~65˚C100-240V AC±10% 50/60Hz10VA 240V AC, 6VA 100V AC(Normal mode) 40 dB or higher (50/60 Hz)(Common mode)120 dB or higher (50/60 Hz)For Voltage (V) input: 90 dB or higher (50/60 Hz)Safety: IEC61010 and EN61010-1EMC: EN61326 (Class A: Industrial environment)Input/output - power supply: 500V DC 20MΩ or aboveInput/output - contact output: 500V DC 20MΩ or aboveInput/output - power supply: 2300V AC 1 minuteContact output - power supply: 2300V AC 1 minuteOnly front panel has dust-proof and drip-proof structureNEMA4X and IP66 PPO resin molding (equivalent to UL94V-1) / IvorySR1: H48 x W48 x D111 (Panel depth: 100) mmSR3: H96 x W96 x D111 (Panel depth: 100) mm
Push-in panel (one-touch mount)1.0~4.0 mmSR1: H45 x W45 mm / Approx. 150 gSR3: H92 x W92 mm / Approx. 270 g
SPECIFICATIONS
48 x 48 Digital Controller96 x 96 Digital Controller
SR4: 96 x 48 Digital Controller
(PV)/4 digit 7 segments red LED (H: 11mm)(SV)/4 digit 7 segments green LED (H: 9.5mm)(PV)/4 digit 7 segments red LED (H: 20mm)(SV)/4 digit 7 segments green LED (H: 13mm)± (0.3%FS + 1 digit) (see "Note" in Measuring Range Codes) (Excluding cold junction compensation accuracy)
23˚C ± 5˚CDepends on measuring range (0.001, 0.01, 0.1, 1)0.5 seconds5 LED lamp displays (OUT/EV1/EV2/AT/MAN)
By operating 4 keys ( , , , )(front panel)
Same as measuring range (within setting limitter)Individual setting for higher & lower limits are possiblewithin measuring range (Lower limit value < Higher limit value)
Selectable from multiple (TC,Pt,mV) and voltage (V)*Current input 0-20mA DC (Voltage: 0-5V), 4-20mA DC(Voltage: 1-5V) applied via 250Ω shunt resistorB,R,S,K,E,J,T,N,PL II,WRe5-26, U,L(DIN 43710)500kΩ minimum
100 Ω maximumStandard feature (up scale)
± 1˚C (within 23˚C ± 5˚C)± 2˚C (ambient temperature: 5˚C to 45˚C)Pt100/JPt100, 3-wire type0.25 mALead wire tolerance:5 Ω max/wire(3 lead wires should have the same resistance.)-10~10,0~10,0~20,0~50,10~50, 0~100mv DCUp scale at time of abnormal input-1~1, 0~1, 0~2, 0~5,1~5, 0~10V DC500kΩ minimumScaling possible for voltage (mV,V) or current (mA) input-1999~9999 counts10~5000 counts(Position) None, 0.0, 0.00, 0.0000.5 seconds-1999~2000 units0~100 secondsInsulated between input and output (not insulatedbetween input and system)
Expert PID control with auto tuning functionOFF, 0.1~999.9%(ON-OFF action by OFF)OFF, 1~6000 seconds (P or PD action by OFF)OFF, 1~3600 seconds (P or PI action by OFF)-50.0~50.0% (Effective when I=OFF)1~999 units (Effective when P=OFF)1~120 seconds (for contact and SSR drive voltage output)
SR4: H92 x W45 mm / Approx. 190 g
SR4: H96 x W48 x D111 (Panel depth: 100) mm
External Dimensions & Panel Cutout
92 +0.80
92+
0.8
0
11
100
111
P V
S V
SR 3
ENT
OUT EV1 EV2 AT MAN
96
96 91.6
1 1
100
111
91.6
PV
S V
ENT
SR 1
OUT EV1 EV2 AT MUN
48
48 44.6
11
100
11145
+0.60
45+
0.6
0
SR1
SR3
96
48
SR 4
EV2EV1
SV
OUT
PV
ENT
MANAT
45+0.6 0
92
+0
.8 0
SR4
Series SR90
SHIMADEN DIGITAL CONTROLLER
°C
%RH
Shimaden, Temperature and Humidity Control Specialists
Multi-input and multi-range performance
Large 20mm bright display (SR93)
Readable from a distance and in a low light area
2-output heating and cooling control available
RS232C or RS485 Interface available
Dust and splash proof front panel equivalent to IP66
A wide selection of additional functions (optional) is
available to suit various needs.
BASIC FEATURES
SPECIFICATIONS Series SR90
Display Digital display: Measured value (PV)/7 segments red LED
4 digits
Target set value (SV)/7 segments green
LED 4 digits
Display accuracy: ±(0.3%FS + 1 digit)
Excluding reference contact temperature
compensation accuracy of thermocouple
input.
Accuracy of readings lower than −100˚C of
thermocouples K, T, U inputs is ±0.7%FS.
Accuracy guarantee not applicable to
400˚C (752˚F) and below of B
thermocouple.
Display accuracy maintaining range:
23˚C ± 5˚C (18~28˚C)
Display resolution: Depends on measuring range (0.001, 0.01,
0.1 and 1)
Measured value display range: −10%~110% of measuring range
Display updating cycle: 0.25 seconds
Action display/color: 7 type, LED lamp display
Control output (OUT1, OUT2)/Green
Event (EV1, EV2)/Orange
Auto tuning/Green
Manual control output (MAN)/Green
Set value bias, communication
(SB/COM)/Green
Setting
Setting method: By operating 4 keys ( , ,
and ) on the front panel
Target value setting range: Same as measuring range (within setting
limiter)
Setting limiter: Individual setting for higher and lower
limits, any value is selectable within
measuring range (Lower limit
value<Higher limit value)
Input Type of input: Selectable from multiple (TC, Pt, mV),
voltage (V) and current (mA)
Thermocouple: B, R, S, K, E, J, T, N, PL II, Wre5-26 U, L
(DIN 43710)
Input impedance: 500kΩ minimum
External resistance tolerance: 100Ω maximum
Burnout function: Standard feature (up scale)
Reference junction compensation accuracy:
± 1˚C (within the accuracy maintaining
range (23 ± 5˚C))
± 2˚C (between 5 and 45˚C of ambient
temperature)
R.T.D.: Pt100/JPt100, 3-wire type
Normal current: 0.25 mA
Lead wire tolerance: 5Ω maximum/wire (3 lead wires should
have the same resistance.)
Voltage mV: −10~10, 0~10, 0~20, 0~50, 10~50,
0~100mv DC
V: −1~1, 0~1, 0~2, 0~5, 1~5, 0~10V
Input impedance: 500kΩ minimum
Current mA: 0~20, 4~20mA DC
Receiving impedance: 250Ω
Input scaling function: Scaling possible for voltage (mV, V) or
current (mA) input
Scaling range: −1999~9999 counts
Span: 10~5000 counts
Position of decimal point: None, 1, 2 and 3 digits on the right of
decimal point
Sampling cycle: 0.25 seconds
PV bias: −1999~2000 units
PV filter: 0~100 seconds
Isolation: Control input not insulated from system, set
value bias, and CT input but insulated from
others
Control Control mode
With 1 output: Expert PID control with auto tuning function
RA (reverse action characteristic): Heating action
DA (direct action characteristic): Cooling action
With 2 outputs: Expert PID control with auto tuning function +
PID control
PID (output 1) + PID (output 2)
ENT
RA (reverse action characteristic): Heating action
(OUT1) and cooling action (OUT2)
DA (direct characteristic): 2-stage heating action
Type of control/rating: Contact/1a 240V AC 2A (resistive load)
1.2A (inductive load)
(Common to Output 1 and 2): SSR drive voltage/12V±1.5V DC
(Maximum load current 30mA)
Current/4~20mA DC (Maximum load
resistance 600Ω)
Voltage/0~10V DC (Maximum load
current 2mA)
Control output resolution: Control output 1: approx. 0.0125% (1/8000)
Control output 2: approx. 0.5% (1/200)
Control output 1
Proportional band (P): OFF, 0.1~999.9% (ON-OFF action by OFF)
Integral time (I): OFF, 1~6000 seconds
(P or PD action by OFF)
Derivative time (D): OFF, 1~3600 seconds
(P or PI action by OFF)
Set value function: OFF, 0.01~1.00
ON-OFF hysteresis: 1~999 units (Effective when P=OFF)
Manual reset: −50.0~50.0% (Effective when I=OFF)
Higher/lower limit output limiter: Lower limit 0.0~99.9%, higher limit
0.1~100.0% (Lower limit value < Higher
limit value)
Proportional cycle: 1~120 seconds (for contact and SSR drive
voltage output)
Control output 2 (option)
Proportional band (P): OFF, 0.1~999.9%
(ON-OFF action by OFF)
Integral time (I): OFF, 1~6000 seconds
(P or PD action by OFF)
Derivative time (D): OFF, 1~3600 seconds
(P or PI action by OFF)
Set value function: OFF, 0.01~1.00
ON-OFF hysteresis: 1~999 units (Effective when P=OFF)
Dead band: −1999~5000 units (Overlap with a negative
value)
Higher/lower limit output limiter: Lower limit 0.0~99.9%, higher limit
0.1~100.0% (Lower limit value < Higher
limit value)
Proportional cycle: 1~120 seconds (for contact and SSR drive
voltage output)
Manual control
Output setting range: 0.0~100.0%
Setting resolution: 0.1%
Manual ↔ auto switching: Balanceless bumpless (within proportional
range)
Soft start: OFF, 1~100 seconds
AT point: SV value in execution
Control output characteristic: RA (reverse action characteristic)/DA
(direct action characteristic) switching by
front key or communication
With 2 outputs: RA (heating/cooling)/DA (2 stage heating)
Isolation: Contact output isolated from all.
Analog output not insulated from SSR drive
voltage, current and voltage but insulated
from others. (In case another output is also
SSR drive voltage, current or voltage,
two outputs are not insulated from
each other.)
Event output (option) Number of event points: 2 points of EV1 and EV2
Types: Selectable from the following 9 types for
EV1 and EV2:
Event setting range: Absolute values (both higher limit and
lower limit): Within measuring range
Deviations (both higher limit and lower
limit): −1999~2000 units
Higher/lower limit deviations
(within/outside): 0~2000 units
: No selection
: H igher limit deviation
: Lower limit deviation
: Outside higher/lower limit deviations
: W ithin higher/lower limit deviations
: H igher limit absolute value
: Lower limit absolute value
: Scaleover
: Heater break/loop alarm
Series SR90
Event action: ON-OFF action
Hysteresis: 1~999 units
Standby action: Selectable from the following 4 types
EV1 and EV2: 1 Without standby action.
2 Standby when power is applied.
3 Standby when power is applied and
when SV value in execution is changed.
4 Control mode without standby action (No
alarm is output at the time of abnormal
input).
Output type/rating: Contact (1a × 2 points common)/240V AC
1A (resistive load)
Output updating cycle: 0.25 seconds
Heater break/heater loop alarm (option)Break/loop detection only for OUT1 (Selectable when output type is
contact or SSR drive voltage)
Current capacity: 30A, 50A to be designated when CT is
ordered.
Alarm action: Heater current is detected by external CT
provided as an accessory.
When heater break is detected while control
output is ON=Alarm output ON
When heater loop alarm is detected while
control output is OFF=Alarm output ON
Current setting range: OFF, 0.1~50.0A (Alarm action is stopped
by setting OFF)
Setting resolution: 0.1A
Current display range: 0.0~55.0A
Display accuracy: ±2.0A (Sine wave at 50Hz)
Minimum time to identify action: 0.25 seconds (every 0.5 seconds) common
to ON and OFF
Alarm retention mode: Selectable from lock (to retain) and real
(not to retain).
Standby action: Selectable from without (OFF) and with
(ON).
Sampling cycle: 0.5 seconds
Isolation: CT input not insulated from system and
other inputs but insulated from the others.
Set value bias (option) Setting range: −1999~5000 units
Action input: Non-voltage contact or open collector (level
action) about 5V DC, 1mA maximum
Minimum level retention time: 0.15 seconds
Isolation: Action input not insulated from system and
other inputs but insulated from others
Communication function (option) Type of communication: RS-232C, RS-485
Communication system: RS-232C 3-line type half duplex system
RS-485 2-line type half duplex system
RS-485 is of half-duplex multi-drop (bus)
system
Synchronization system: Start-stop synchronization system
Communication distance: RS-232C The longest: 15 m
RS-485 The longest 500 m (depending on
conditions)
Communication speed: 1200, 2400, 4800, 9600, 19200 bps
Data format: 7 bits, even parity, 1 stop bit or
8 bits, non-parity, 1 stop bit
Communication address: 1~255
Communication memory mode: EEP/RAM/r_E
Communication BCC: Add/Add two's cmp/XOR/None
Communication delay time: 1~100 (× 0.512 msec)
Communication code: ASCII code
Communication protocol: Shimaden's standard protocol
Number of connectable instruments:
RS-232 1
RS-485 up to 31
Isolation: Communication signals insulated from
system, each input and each output.
Analog output (option) Number of output points: 1 point
Type of analog output: Selectable from measured value, target
value (SV in execution), control output 1
and control output 2.
Output signal/rating: 4~20mA DC/Maximum load resistance 300Ω
0~10V DC/Maximum load current 2mA
0~10mV DC/Output resistance 10Ω
Output scaling: Measured value, target value: Within
measuring range (inversed scaling possible)
Control output 1 and 2 0.0~100.0%
(inversed scaling possible)
Output accuracy: ±0.3% FS (with respect to displayed value)
Output resolution: Approx. 0.01% (1/10000)
Output updating cycle: 0.25 seconds
Isolation: Analog output insulated from system and
inputs but not insulated from control output
except contact output.
General specifications Data storage: Non-volatile memory (EEPROM)
Environmental conditions for instrument operation:
Temperature: −10~50˚C
Humidity: 90% RH or less (no dew condensation)
Height: 2000m from the sea level or lower
Category: II
Degree of pollution: 2
Storage temperature: −20~65˚C
Supply voltage: Either 100-240V AC±10% 50/60Hz or
24V AC/DC±10% to be designated.
Power consumption: SR91: 100-240VAC 11VA maximum for
AC; 6W for DC 24V; 7VA for AC 24V
SR92, SR93 and SR94: 100-240VAC
15VA maximum for AC; 8W for DC
24V; 9VA for AC 24V
Input/noise removal ratio: 50 dB or higher in normal mode (50/60 Hz)
130 dB or higher in common mode
(50/60 Hz)
Applicable standards: Safety: IEC1010 and EN61010-1
EMC: EN61326
Insulation resistance: Between input/output terminals and power
terminal 500V DC 20MΩ or above;
Between input/output terminals and
protective conductor terminal 500V DC
20MΩ or above
Dielectric strength: Between input/output terminals and power
terminal 2300V AC/minute; Between
power terminal and protective conductor
terminal 1500V AC/minute
Protective structure: Only front panel has dust-proof and drip-
proof structure equivalent to IP66.
Material of case: PPO resin molding
(equivalent to UL94V-1)
External dimensions:
SR91: H48 × W48 × D111 (Panel depth: 100) mm
SR92: H72 × W72 × D111 (Panel depth: 100) mm
SR93: H96 × W96 × D111 (Panel depth: 100) mm
SR94: H96 × W48 × D111 (Panel depth: 100) mm
Mounting: Push-in panel (one-touch mount)
Panel thickness: 1.0~4.0 mm
Panel cutout: SR91: H45 × W45 mm
SR92: H68 × W68 mm
SR93: H92 × W92 mm
SR94: H92 × W45 mm
Weight: SR91: Approximately 170 g
SR92: Approximately 280 g
SR93: Approximately 330 g
SR94: Approximately 240 g
ITEM CODE SPECIFICATIONS
SERIES SR91-
INPUT
Multi input
CONTROL OUTPUT (1)
POWER SUPPLY
REMARKS
OPTION
Control output (2)
Heater break alarm
Analog output
Communication
Set value bias
EVENT OUTPUT (OPTION)
4
8
6
Y-
I-
P-
V-
90-
08-
0
1
N
Y
I
P
V
1
2
8
3
4
6
5
0
9
MPU-Based Auto-Tuning PID Digital Controller, DIN H48 W48 D110mm
Thermocouple: B, R, S, K, E, J, T, N, PLII, Wre5-26 U, L (DIN 43710)
R.T.D.: Pt100 Ω /JPt100 Ω
Voltage: -10~10, 0~10, 0~20, 0~50,
10~50, 0~100mV DC
Current (mA): 0~20, 4~20mA DC
Receiving impedance: 250 Ω
Voltage (V): -1~1, 0~1, 0~2, 0~5,
1~5, 0~10V DC
For voltage and current input:
Scaling Possible
Range: -1999~9999
Span: 10~5000
Note: Inverse scaling
is not possible
Contact: 1a, Contact capacity: 240V AC 2.5A/resistive load
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600 Ω max.
SSR drive voltage: 12V 1.5V DC/30mA max.
Proportional cycle: 1~120 sec.
Voltage: 0~10V DC
Load current: 2mA max.
100~240V AC 10%, 50/60Hz
24V AC/DC 10%, 50/60Hz
None
Contact output (2a) Ev1, Ev2: 240V AC 1A/resistive load
None
Contact: 1a, Contact capacity: 240V AC 2.5A/resistive load
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600 Ω max.
Proportional cycle: 1~120 sec.
SSR drive voltage: 12 1.5V DC/30mA max.
Load current: 2mA max.
Voltage: 0~10V DC
Current setting range: 0.1~30.0A (with CT 30A)
Current setting range: 0.1~50.0A (with CT 50A)
when control output (1)
Note: Avaialble only
output is selected.
is Y or P and when event
Current: 4~20mA DC, Load resistance: 300 Ω max.
Voltage: 0~10mV DC, Output resistance: 10 Ω
RS-485
Voltage: 0~10V DC, Load current: 2mA max.
Open collector input rating: approx. 5V/1mA max.
1 point (setting range: -1999~5000), Non-voltage contact or Open collector input
With (Please consult before ordering.)
Without
Note:
When you purchase a two-output type controller and use it in a one output capacity, larger overshooting or undershooting may happen as
a result of integral operation. Therefore, we recommend you to choose a one-output type.
The cause of the above-mentioned problem is that the positional relationship between the proportional band (PB) and the set value (SV)
of a one-output type controller differs from that of a two-output type.
Series SR90
× ×
±
Series SR90
ITEM CODE SPECIFICATIONS
SERIES SR92-
INPUT
Multi input
CONTROL OUTPUT (1)
CONTROL OUTPUT (2)(OPTION)
POWER SUPPLY
REMARKS
ANALOG OUTPUT (OPTION)
COMMUNICATION OR SV BIAS (OPTION)
EVENT OUTPUT/HEATER BREAK ALARM (OPTION)
4
8
6
Y-
I-
P-
V-
Y-
N-
I-
P-
V-
90-
08-
0
1
2
3
0
9
MPU-Based Auto-Tuning PID Digital Controller, DIN H72 × W72 × D110mm
Thermocouple: B, R, S, K, E, J, T, N, PLII, Wre5-26 U, L (DIN 43710)
R.T.D.: Pt100Ω /JPt100Ω
Voltage (mV): -10~10, 0~10, 0~20,
0~50, 10~50, 0~100mV DC
Current (mA): 0~20, 4~20mA DC
Receiving impedance: 250Ω
Voltage (V): -1~1, 0~1, 0~2, 0~5, 1~5,
0~10V DC Input resistance: 500kΩ min.
Scaling Possible
For voltage and current input:
Range: -1999~9999
Span: 10~5000
Note: Inverse scaling
is not possible.
Contact: 1a, Contact capacity: 240V AC 2A/resistive load
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600Ω max.
SSR drive voltage: 12V±1.5V DC/30mA max.
Proportional cycle: 1~120 sec.
Voltage: 0~10V DC
Load current: 2mA max.
Contact: 1a, Contact capacity: 240V AC 2A/resistive load
None
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600Ω max. (RA when shipped)
SSR drive voltage: 12V±1.5V DC/30mA max.
Proportional cycle: 1~120 sec.
Voltage: 0~10V DC
Load current: 2mA max.
100V~240V AC±10%, 50/60Hz
24V AC/DC±10%, 50/60Hz
None
Event output (2a) Ev1, Ev2
Contact capacity: 240V AC 1A/resistive load
Event output (Ev1) + Heater break alarm (with CT30A)
Event output (Ev1) + Heater break alarm (with CT50A)
Voltage: 0~10mV DC, Output resistance: 10Ω
None
Voltage: 0~10V DC, Load current: 2mA max.
Current: 4~20mA DC, Load resistance: 300Ω max.
RS-485
None
1 point (setting range: -1999~5000), Non-voltage contact or Open collector input
RS-232C
when control output (1)
Note: Available only
is Y or P is selected.
With (Please consult before ordering.)
Open collector input rating: approx. 5V/1mA max.
Without
0
3
4
0
5
7
8
6
Note:
When you purchase a two-output type controller and use it in a one output capacity, larger overshooting or undershooting may happen as
a result of integral operation. Therefore, we recommend you to choose a one-output type.
The cause of the above-mentioned problem is that the positional relationship between the proportional band (PB) and the set value (SV)
of a one-output type controller differs from that of a two-output type.
Series SR90
ITEM CODE SPECIFICATIONS
SERIESSR94-
SR93-
INPUT
Multi input
CONTROL OUTPUT (1)
POWER SUPPLY
REMARKS
OPTION
Analog output
Communication
Set value bias (S V bias)
EVENT OUTPUT/HEATER BREAK ALARM (OPTION)
4
8
6
Y-
I-
P-
V-
Y-
I-
P-
V-
N-
08-
90-
0
1
2
3
00
08
38
68
Analog output +Set value bias (S V bias)
48
30
40
60
05
0
9
MPU-Based Auto-Tuning PID Digital Controller, DIN H96 × W48 × D110mm
MPU-Based Auto-Tuning PID Digital Controller, DIN H96 × W96 × D110mm
Thermocouple: B, R, S, K, E, J, T, N, PLII, Wre5-26 U, L (DIN 43710)
R.T.D.: Pt100Ω /JPt100Ω
Voltage: -10~10, 0~10, 0~20,
0~50, 10~50, 0~100mV DC
Current (mA): 0~20, 4~20mA DC
Receiving impedance: 250Ω
Voltage (V): -1~1, 0~1, 0~2, 0~5, 0~10V DC
Load resistance: 600Ω max.
Scaling Possible
Range: -1999~9999
Span: 10~5000
Note: Inverse scaling
is not possible
Contact: 1a, Contact capacity: 240V AC 2A/resistive load
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600Ω max.
SSR drive voltage: 12V±1.5V DC/30mA max.
Proportional cycle: 1~120 sec.
Voltage: 0~10V DC
Load current: 2mA max.
None
None
None
Current: 4~20mA DC, Load resistance: 300Ω max.
Voltage: 0~10mV DC, Output resistance: 10Ω
Voltage: 0~10mV DC, Output resistance: 10Ω
SV bias 1 point
Current: 4~20mA DC, Load resistance: 300Ω max.
SV bias 1 point
Voltage: 0~10V DC, Load current: 2mA max.
SV bias 1 point
RS-485
07 RS-232C
Voltage: 0~10V DC, Load current: 2mA max.
Open collector input rating: approx. 5V/1mA max.
1 point (setting range: -1999~5000), Non-voltage contact or Open collector input
With (Please consult before ordering.)
Without
Contact: 1a, Contact capacity: 240V AC 2A/resistive load
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600Ω max.
SSR drive voltage: 12V±1.5V DC/30mA max.
Proportional cycle: 1~120 sec.
Voltage: 0~10V DC
Load current: 2mA max.
100~240V AC±10%, 50/60Hz
24V AC/DC±10%, 50/60Hz
Event output (2a) Ev1, Ev2
Contact capacity: 240V AC 1A/resistive load
Event output (Ev1) + Heater break alarm (with CT30A)
Event output (Ev1) + Heater break alarm (with CT50A)
when control output (1)
Note: Available only
is Y or P is selected.
CONTROL OUTPUT (2)(OPTION)
For voltage and current input:
Note:
When you purchase a two-output type controller and use it in a one output capacity, larger overshooting or undershooting may happen as
a result of integral operation. Therefore, we recommend you to choose a one-output type.
The cause of the above-mentioned problem is that the positional relationship between the proportional band (PB) and the set value (SV)
of a one-output type controller differs from that of a two-output type.
External Dimensions Panel Cutout
Series SR90SR91
SR92
OUT1 OUT2 EV1 EV2 AT MAN SB/COM
48
48
ENT
SR91
PV
SV C
45+0.60 (48 × N−3)+1
0
45
+0.6
0
45
+0.6
0
60 o
r m
ore
In the case of installation without leaving spacebetween instruments
N=The number of instruments
Unit: mm
11 100
111
44.6
11
12
11
12
11 1 11
1212
+
−
+
−
+
−
4-20mA0-10V30mA 12V
2A 240V
DCDCDC
AC
OUTPUT2
CT/SBSG
RS-485
A-output
1 11 6
7
8
9
10
12
13
14
15
2
3
4
5
+
L
N
−
+
−+ +
− −
A
B
B
DCCOM
EV11A240VAC
EV21A240VAC
4-20mA0-10V30mA 12V
2A 240V
DCDCDC
AC
100-240VAC~50/60Hz 11VA
24VDC 6W/24VAC~50/60Hz 7VA
OUTPUT1
Terminal Arrangement
SR93 AND SR94
11 100
111
67.6
OUT1
OUT2
EV1
EV2
AT
MAN
SB/COM
72
72
ENT
SR92
PV
SV ˚C
68 +0.70
68
+0
.70
10
0 o
r m
ore
100 or more
Unit: mm
1 15 8
9
10
11
12
13
14
16
17
18
19
20
21
2
3
4
5
6
7
+ +
− −
A
B
B
DC
+
−
+
−
COM
EV11A240VAC
EV21A240VAC
L
N
100-240VAC~50/60Hz 15VA
24VDC 8W/24AVC~50/60Hz 9VA
4-20mA0-10V30mA 12V
2A 240V
DCDCDC
AC
OUTPUT1
4-20mA0-10V30mA 12V
2A 240V
DCDCDC
AC
OUTPUT2
SB A-output
CT+
−
+
−
∗1
∗1
1
SG
SG SD RD
2 3
+ −
SPECIFICATION
TERMINAL
RS-232C
RS-485
1
2
3
Panel Cutout
• SR93
External Dimensions Panel Cutout
48 11 100
96
111
91
.6 ×
44
.6
OUT1 OUT2 EV2EV1 AT MAN SB/COM
SR94
96
96
ENT
SR93
11 100
111
91
.6
PV
SV ˚C
OUT1 OUT2
EV1 EV2 AT MAN SB/COM
ENT
PV
SV C
45+0.60 (48 × N−3)+1
0
92
+0
.80
92
+0
.80
130 o
r m
ore
In the case of installation without leaving spacebetween instruments
N=The number of instruments
Unit: mm
92 +0.80
92
+0
.80
130 o
r m
ore
130 or more
Unit: mm
13
14
15
16
17
18
19
20
11
12
1
2
3
4
5
6
7
9
10
8
+ +
− −
A
B
B
DCCOM
EV11A240VAC
EV21A240VAC
DCDCDC
AC
DCDCDC
AC
+
−
A-output
SB
CT
+
−
+
−
L
N
100-240VAC~50/60Hz 15VA
4-20mA0-10V30mA 12V
2A 240V
OUTPUT1
4-20mA0-10V30mA 12V
2A 240V
OUTPUT2
+
−
24VDC 8W/24AVC~50/60Hz 9VA
∗11
SG
SG SD RD
2 3
+ −
SPECIFICATION
TERMINAL
RS-232C
RS-485
∗1
1
2
3
4
External Dimensions
Terminal Arrangement (Common)
Terminal Arrangement
• SR94
MEASURING RANGE CODES
TERMINAL COVER (AVAILABLE SEPARATELY)
Warning
• The SR90 series is designed for the control of temperature, humidity and other physical values of general industrial
equipment. (It is not to be used for any purpose which regulates the prevention of serious effects on human life or safety.)
Caution
• If the possibility of loss or damage to your system or property as a result of failure of any part of the process exists,
proper safety measures must be made before the instrument is put into use so as to prevent the occurrence of trouble.
ISO 9001
(The contents of this brochure are subject to change without notice.)
02DSR90500ILC
Material/Appearance: PVC/transparent
Thickness: 1 mm
Mounting: 2+B tight pan-head screws
M2.3 × 6mm
Temperature and Humidity Control Specialists
Head Office: 2-30-10 Kitamachi, Nerima-Ku, Tokyo 179-0081 JapanPhone: +81-3-3931-7891 Fax: +81-3-3931-3089
E-MAIL: [email protected] URL: http://www.shimaden.co.jp
Measuring range (°C) Measuring range (°F)
0
0.0
0
0
0
-199.9
-199.9
-200
-200
0
0
0
0
0
0
-199.9 400.0
800.0
200.0
200.0
-100.0
-50.0 50.00.0 200.0
-100.0
-50.0
0.0
100.0
100.0
50.0
200.0
1700
1200
1300
1300
2300
700
600
600
600
500
1700
1800
Code
0
0
0
0
0
-300
-300
0
0
0
0
0
0
-300 750
1500
400
400
200.0
3100
2200
2300
2300
4200
1300
1100
1100
31003300
-300 1100
-300 1000
-150.0 200.0-150.0
200.0-150.0
400.00.0
400.00.0
120.0-50.0
J
T
N
PLII
WRe5-26
U
L
Pt100
Jpt100
BR
S
K
K
KE
*1
*2
*2
*2
*3
-10 10
10
20
50
50
100
0
0
0
10
0
92
01
02
03
04
05
06
07
08
09
10
11
12
13
14
31
32
33
34
35
36
37
38
71
72
73
74
76
75
81
82
83
84
86
85
91
1-1
10
20
50
51
100
200
204
Input Type
Thermo-couple
Multi-in
put
Voltage(mV)
Voltage (V)
Current (mA)
R.T.D.
Owing to scaling function, any measuring range can be set within the following range.
Scaling range: Span:
*1 Thermocouple: B: Accuracy guarantee not applicable to
400˚C (752˚F) and below.
*2 Thermocouple K, T, U: Accuracy of those whose
readings are below -100˚C is ±0.7% FS
*3 Thermocouple PLII: Platinel
*4 Thermocouple Wre5-26: A product of Hoskins
*5 Thermocouple U, L: DIN 43710
-1999 to 9999 counts10 to 5000 counts on condition of lower side < higher side
-50.0 120.0
Measuring rangeInput Specification/Rating
0.0 ~ 800.0˚CMulti-input K thermocouple
0.0 ~ 100.0Voltage (V) 0 ~ 10V DC
0.0 ~ 100.0Current (mA) 4 ~ 20mA DC
NOTE:Unless otherwise specified, the measuring range will be set as listed below
during the shipment from the factory.
*4
*5
*5
Scaling possible
Refer to the informationon the right.
Series SR90
SR91
SR92
SR93
QCR001
QCR002
QCR003
One-touchmountOne-touchmount
One-touchmount
Model Mounting
SR94
QCR004
QCR005
Plus screw, B tight,M2.3 × 6 - 2 pcs.
Plus screw, B tight,M2.3 × 6 - 4 pcs.
Model
(Individual mounting)
(Tight-lock coupling)
Mounting
Material/Appearance: PVC/transparent Thickness: 1 mm