+ All Categories
Home > Documents > Conventional Fire Alarm System Product Range...

Conventional Fire Alarm System Product Range...

Date post: 20-Sep-2020
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
8
CONTENTS Conventional Fire Alarm System Zc1004 Conventional Fire Alarm Control Panel ZC1008 Conventional Fire Alarm Control Panel ZC P1004 Conventional Fire Alarm Control Panel ZP1008 Conventional Fire Alarm Control Panel ZP1012 Conventional Fire Alarm Control Panel ZP1016 Conventional Fire Alarm Control Panel Z 1002M/S Conventional Fire Alarm Control Panel 102C Conventional Smoke Detector ZC102M Mini Conventional Smoke Detector ZC 105C Conventional Heat Detector 105M Mini Conventional Heat Detector 106 Conventional Manual Call Point 108 Conventional Sound Strobe 188-6 Conventional Alarm Bell ZC188-8 Conventional Alarm Bell ZC 10016 Conventional Fire Alarm Control Panel Z P1016 Repeater Panel ZC ZC102 Conventional Smoke Detector ZC 105 Conventional Heat Detector ZC ZC ZC103 Conventional Smoke & Heat Detector ZC ZC116 Conventional Manual Call Point ZC ZC109 Conventional Sound Strobe ZC 188-10 Conventional Alarm Bell Remote LED ZC111 Smoke Testing Pole JY117 2 EXPERT IN SAFETY AND SECURITY TECHNOLOGY Conventional Fire Alarm System Product Range Guide Date: 2012.08
Transcript
Page 1: Conventional Fire Alarm System Product Range Guidedoc.diytrade.com/docdvr/947747/45361884/1467893009.pdf · 2016. 7. 7. · Conventional Fire Alarm System Product Range Guide Date:

CONTENTS

Conventional Fire Alarm System

Zc1004 Conventional Fire Alarm Control PanelZC1008 Conventional Fire Alarm Control PanelZC

P1004 Conventional Fire Alarm Control PanelZP1008 Conventional Fire Alarm Control PanelZP1012 Conventional Fire Alarm Control PanelZP1016 Conventional Fire Alarm Control Panel

Z

1002M/S Conventional Fire Alarm Control Panel

102C Conventional Smoke DetectorZC102M Mini Conventional Smoke Detector

ZC105C Conventional Heat Detector105M Mini Conventional Heat Detector

106 Conventional Manual Call Point

108 Conventional Sound Strobe

188-6 Conventional Alarm BellZC188-8 Conventional Alarm BellZC

10016 Conventional Fire Alarm Control Panel

Z

P1016 Repeater Panel

ZC

ZC102 Conventional Smoke DetectorZC

105 Conventional Heat DetectorZCZC

ZC103 Conventional Smoke & Heat Detector

ZCZC116 Conventional Manual Call Point

ZCZC109 Conventional Sound Strobe

ZC

188-10 Conventional Alarm Bell

Remote LED ZC111

Smoke Testing Pole JY117

2

EXPERT IN SAFETY ANDSECURITY TECHNOLOGY

Conventional Fire Alarm System Product Range Guide

Date: 2012.08

Page 2: Conventional Fire Alarm System Product Range Guidedoc.diytrade.com/docdvr/947747/45361884/1467893009.pdf · 2016. 7. 7. · Conventional Fire Alarm System Product Range Guide Date:

INTRODUCTIONOver the past twenty years, We have always been dedicated to serving the diverse

needs of our customers. Although we started out as a tiny engineering and

manufacturing company in China and have grown into a global player in the

international safety market, Tech continues to work hard to earn your trust

and retain your confidence in our product line.

ZoancoTech manufactures thousands of uniquely made smoke, heat and gas

detectors annually, fulfilling a special role or function for each of our customers.

Tech can custom-design detectors specifically for your applications. From

product design to final manufacturing, we offer one-stop shopping for your residential

and commercial detector needs. Any one of our existing product designs can also be

modified to meet your specific requirements. In a "one-size-fits-all" world,

ZoancoTech works harder to tailor our solutions to meet your needs.

Tech is an ISO 9001:2000 certified manufacturer with an extended network of

manufacturing subcontractors and suppliers located nearby. Our company currently

owns a number of testing facilities, such as a UL-standard fire testing lab, a UL test

box, a dust test chamber, an EN-54 testing tunnel, a buzzer sound-level trial station

and a fluorescent-light interference testing site as well as EMC test equipment. We

are also planning to expand our manufacturing and testing facilities in China to

ensure that our products and manufacturing practices continue to meet the highest

standards.

Smoke, heat, and gas detector manufacturing isn’t an easy business to be in. Faced

with the stiff competition from cheaply made, low-quality detectors, we remain

committed to our customers with high quality products at the most reasonable prices.

Our focus is to deliver meaningful value to clients that choose our brand over the

competition through our commitment to quality. This year we are preparing to

introduce our new line of advanced, feature-rich conventional and addressable

detectors and panels at a competitive price.

We invite you to get to know Tech better. Experience the very best in smoke

detector technology. We are convinced that you will find Tech superior to any

other detector company in China. You'll see it in our facilities, in our people, and in

the products that Tech makes. It's our uncommon commitment to excellence

and quality, and to the automation and productivity of our customers.

Zoanco

Zoanco

Zoanco

Zoanco

Zoanco

Zoanco

Intro

du

ctio

n

3 4

Co

nven

tio

nal F

ire A

larm

Pan

el

Conventional Fire Alarm Control Panel

Model: 1008ZC

Model: 1016ZC

4 Zone Fire Alarm Control Panel

8 Zone Fire Alarm Control Panel

16 Zone Fire Alarm Control Panel

Model:ZC1004

General

AC POWER: 90 to 270VAC, 50 Hz, 3.0 amps.

2Wire size: minimum 14 AWG (2.0 mm) with 600-volt insulation.BATTERY:Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery.

FeaturesFour to Sixteen Style B (Class B) Initiating Device Circuits

(IDCs).

All zones accept two-wire smoke detectors and any normally-

open contact devices.

Zones 1 - 16 configured as general alarm zones.

All circuits are power-limited and supervised, meeting the latest

ULC requirements using

fuseless technology.

Two built-in, Style Y (Class B) Notification Appliance (Signal)

Circuits (NACs).

NACs may be programmed: Silenceable,Non-Silenceable, Auto-

Silence

1.25 amps of NAC power. 3.00 amps of total system power.

Alarm, Trouble and Supervisory, relay output. 24 volt operation.

Resettable four-wire smoke detector power @ 500 mA. Non-

resettable power @ 500 mA.

Integral battery charger capable of charging up to 18 AH

batteries (batteries over 4 AH

require use of the external battery backbox, or ULC listed

equivalent).

Disable/Enable control per IDC.

Reverse polarity protection.

The Zc1000 Series Conventional Fire Alarm Control Panel is a 24 volt, four, eight, sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective Zc1000 Series can be used in a variety of low- to mid-sized applications.

Specifications

Page 3: Conventional Fire Alarm System Product Range Guidedoc.diytrade.com/docdvr/947747/45361884/1467893009.pdf · 2016. 7. 7. · Conventional Fire Alarm System Product Range Guide Date:

Conventional Fire Alarm Control Panel16 Zone Fire Alarm Control PanelModel: P1016Z

Conventional Fire Alarm Control Panel

Model: P1008Z

Model:ZP1012

4 Zone Fire Alarm Control Panel

8 Zone Fire Alarm Control Panel

12 Zone Fire Alarm Control Panel

Model: P1004Z

The panel is a conventional fire detection control panel and indication control panel, designed to meet all the requirements of EN54-2&4 Microprocessor-based conventional fire alarm control panel One man test 4 Detection Zones Panel, 25 Detectors per Zone 2 Relay outputs for fire conditionZones Fault LEDs indication, Zones Isolation LEDs indicationFault Relay Output, Auxiliary Output for 28VoltsRS485 Port for repeater up to 1.2KmUp to 8 repeaters can be connected to one panel2 sound OutputsSwitched mode power supply 24V,3A with 2 battery chargers 12VEnd Of Line Status Detection, Short circuit /open circuit detection Open collector fault output 28V 50mA fused supply output on FireSwitched mode power supply 3A output

The panelcontrol panel designed to meet all the requirements of EN54-2&4Microprocessor-based conventional fire alarm control panel One man test8 Detection Zones Panel, 25 Detectors per Zone 2 Relay outputs for fire conditionZones Fault LEDs indication, Zones Isolation LEDs indicationFault Relay Output, Auxiliary Output for 28Volts RS485 Port for repeaters up to 1.2Km Up to 8 repeaters can be connected to one panel2 sound outputsSwitched mode power supply 24V,3A with 2 battery chargers 12VEnd of Line Status Detection, Short circuit /open circuit detection Open collector fault output 28V 50mA fused supply output on FireSwitched mode power supply 3A output

is a conventional fire detection control panel and indication

The panelcontrol panel designed to meet all the requirements of EN54-2&4Microprocessor-based conventional fire alarm control panel One man test 12 Detection Zones Panel, 25 Detectors per Zone 2 Relay outputs for fire conditionZones Fault LEDs indication, Zones Isolation LEDs indicationFault Relay Output, Auxiliary Output for 28Volts RS485 Port for repeater up to 1.2Km Up to 8 repeaters can be connected to one panel2 sound outputsSwitched mode power supply 24V,3A with 2 battery chargers 12VEnd of Line Status Detection, Short circuit /open circuit detection Open collector fault output 28V 50mA fused supply output on FireSwitched mode power supply 3A output

is a conventional fire detection control panel and indication

The panelcontrol panel designed to meet all the requirements of EN54-2&4Microprocessor-based conventional fire alarm control panel One man test 16 Detection Zones Panel, 25 Detectors per Zone 2 Relay outputs for fire conditionZones Fault LEDs indication, Zones Isolation LEDs indicationFault Relay Output, Auxiliary Output for 28Volts RS485 Port for repeater up to 1.2Km Up to 8 repeaters can be connected to one panel2 sound outputsSwitched mode power supply 24V,3A with 2 battery chargers 12VEnd of Line Status Detection, Short circuit /open circuit detection Open collector fault output 28V 50mA fused supply output on FireSwitched mode power supply 3A output

is a conventional fire detection control panel and indication

Co

nven

tio

nal F

ire A

larm

Pan

el

Sm

oke

Ala

rmC

on

ven

tion

al F

ire A

larm

Pan

el

5 6

The repeater is a conventional fire alarm repeater panel and indication control panel designed to meet all the requirements of EN54-2&4Microprocessor-based conventional fire alarm repeater panel 16 Detection Zones Repeater PanelRelay output for fire condition Zones Fault LEDs indication, Zones Fire LEDs indicationRS485 Port for panel connection up to 1.2KmUp to 8 repeaters can be connected to one panelSound outputs24 Volts needed from panel4 wire connections to main panel: 2 for power , 2 for RS485This repeater can be connected to any our fire alarm control panel from 4 Zone to 16 Zone Panels

Model: 1016ZC

16 Zone Repeater Panel

The mini 2 zone panel have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Mater panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault. Mini size as 108X143X40mmMaster panel has 4 digital LED display to show slave number and status.2 Detection Zones Panel, 25 Detectors per Zone Fire 1 relay would be activated when one zone alarms.Fire 2 relay would be activated after 30 seconds delay when two zones alarm.1 Sound relay output for sound alarm1 Fault relay output for fault condition Zones Fire and Fault LEDs indicationFire1, Fire2, Sound relay outputs can be activated manuallyRS485 Port for repeater up to 1.2KmUp to 31 Slave panels can be connected to one Master panelPowered by outside DC22-26V power supplyEnd Of Line Status Detection, Short circuit /open circuit detection

Model: 1002M/SZC

2 Zone Fire Alarm Control Panel

Slave Panel

Master Panel

Page 4: Conventional Fire Alarm System Product Range Guidedoc.diytrade.com/docdvr/947747/45361884/1467893009.pdf · 2016. 7. 7. · Conventional Fire Alarm System Product Range Guide Date:

7 8

Model:ZC102Conventional Smoke Detector

Model: 105ZCConventional Heat Detector

Conventional Prouducts

Compatible with all the conventional fire alarm control panel

Unpolarized wire input

Wide range of operating voltages

Unique optical sensing chamber

Built in microprocessor intelligent software

Two LEDs blink standby, provide 360° visibility

Insect-resistant screening

Twist-on mounting base with tamper lock

Drift compensation and smoothing algorithms

Remote Indicator LED can be connected.

Compatible with all the conventional fire alarm control panel

Unpolarized wire input

Wide range of operating voltages

High precision electronic thermistor

Built in microprocessor intelligent software

Two LEDs blink standby, provide 360° visibility

Insect-resistant screening

Twist-on mounting base with tamper lock

Remote Indicator LED can be connected.

Co

nven

tio

nal P

rod

uct

EN54

ApprovedEN54

Pending

Model: 102CZCConventional Smoke Detector

Model: 105CZCConventional Heat Detector

Conventional Prouducts

Compatible with all the conventional fire alarm control panel

Unpolarized wire input

Wide range of operating voltages

Unique optical sensing chamber

Built in microprocessor intelligent software

Two LEDs blink standby, provide 360° visibility

Insect-resistant screening

Twist-on mounting base with tamper lock

Drift compensation and smoothing algorithms

Remote Indicator LED can be connected.

Compatible with all the conventional fire alarm control panel

Unpolarized wire input

Wide range of operating voltages

High precision electronic thermistor

Built in microprocessor intelligent software

Two LEDs blink standby, provide 360° visibility

Insect-resistant screening

Twist-on mounting base with tamper lock

Remote Indicator LED can be connected.

Sm

oke

Ala

rmC

on

ven

tion

al P

rod

uct

Model: 102MZCMini Conventional Smoke Detector

Compatible with all the conventional fire alarm control panel

Unpolarized wire input

Wide range of operating voltages

Unique optical sensing chamber

Built in microprocessor intelligent software

Two LEDs blink standby, provide 360° visibility

Insect-resistant screening

Twist-on mounting base with tamper lock

Drift compensation and smoothing algorithms

Remote Indicator LED can be connected.Mini size: Diameter 64mm, Height 42mm(include base)Diameter 64mm,Height 42mm

Model: 105MZCMini Conventional Heat Detector

Compatible with all the conventional fire alarm control panel

Unpolarized wire input

Wide range of operating voltages

High precision electronic thermistor

Built in microprocessor intelligent software

Two LEDs blink standby, provide 360° visibility

Insect-resistant screening

Twist-on mounting base with tamper lock

Remote Indicator LED can be connected.Mini size: Diameter 64mm, Height 42mm(include base)

Diameter 64mm,Height 42mm

Page 5: Conventional Fire Alarm System Product Range Guidedoc.diytrade.com/docdvr/947747/45361884/1467893009.pdf · 2016. 7. 7. · Conventional Fire Alarm System Product Range Guide Date:

9 10

Co

nven

tio

nal P

rod

uct

Sm

oke

Ala

rmC

on

ven

tion

al P

rod

uct

Conventional Prouducts

Model: 106ZCConventional Manual Call Point

Model: 109ZCConventional Sound Strobe

Conventional Prouducts

Compatible with all the conventional fire alarm control panel

Can be reset by key

470 Ohm resistance

Easy surface mounting Base included

Compatible with all the conventional fire alarm control panel

Long light life up to 40000 flahsed

High sound level up to 100dB

Model: 103ZCConventional Smoke & Heat Detector

Compatible with all the conventional fire alarm control panel

Unpolarized wire input

Wide range of operating voltages

Unique optical sensing chamber and High precision electronic

thermistor

Built in microprocessor intelligent software

Two LEDs blink standby, provide 360° visibility

Insect-resistant screening

Twist-on mounting base with tamper lock

Drift compensation and smoothing algorithms

Remote Indicator LED can be connected.

Model: 116ZCConventional Manual Call Point

Compatible with all the conventional fire alarm control panel

Can be reset by key

Push & Pull down operation

Easy surface mounting Base included

Model: 108ZCConventional Sound Strobe

Compatible with all the conventional fire alarm control panel

Long LED light life up to 100000 flahsed

High sound level up to 100dB

Page 6: Conventional Fire Alarm System Product Range Guidedoc.diytrade.com/docdvr/947747/45361884/1467893009.pdf · 2016. 7. 7. · Conventional Fire Alarm System Product Range Guide Date:

Conventional Prouducts Conventional Prouducts

11 12

Co

nven

tio

nal P

rod

uct

Sm

oke

Ala

rmC

on

ven

tion

al P

rod

uct

Model: 188-10ZC

Conventional Alarm Bell

Three module size of 10 inch

Compatible with all the conventional fire alarm control panel

High sound level up to 95dB

Easy installation bracket included

Steel material

Model: 111ZC

Compatible with all the conventional fire alarm control panel

Red Color

8mm Big Size LED

Outside two holes provide 83mm(USA)

Inner two holes provide 59mm(Europe)

Wiring Terminals provided on the PCB board

Remote LED

Model: JY117Smoke Testing Pole

Smoke detector testing instrument

Max. Pole length is 5m

Easy to use, all the parts in one case

Model: 188-8ZC

Conventional Alarm Bell

Three module size of 8 inch

Compatible with all the conventional fire alarm control panel

High sound level up to 95dB

Easy installation bracket included

Steel material

Model: 188-6ZC

Conventional Alarm Bell

Three module size of 6 inch

Compatible with all the conventional fire alarm control panel

High sound level up to 95dB

Easy installation bracket included

Steel material

Page 7: Conventional Fire Alarm System Product Range Guidedoc.diytrade.com/docdvr/947747/45361884/1467893009.pdf · 2016. 7. 7. · Conventional Fire Alarm System Product Range Guide Date:

13 14

CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE

End of Line Resistor

SmokeDetector

HeatDetector

Smoke & HeatDetector

Alarm Relay Output

Fault Relay Output

Supervisory Relay Output

SmokeDetector

HeatDetector

ManualCall Point

SmokeDetector

ManualCall Point

SmokeDetector

HeatDetector

Bell Bell Sound StrobeSoundStrobe

SoundStrobe

IR IntruderDetector

IR IntruderDetector

Magnetic Door Contact

DC

12V

Out

put

for

secu

rity

prod

ucts

Sup

ervi

sory

Inpu

t1

Supervisory Input2

Resetable DC24V output

Non-Resetable DC24V output

DC12V +

NOCOM

NOCOM

NOCOM

DC24+DC24-

DC24+DC24-

DC12V +

DC12V -

ZONE+

ZONE-

ZONE+

ZONE-

ZONE 1

ZONE 16

SOUND 1

SOUND2( 8 ZONE)

SOUND4( 16 ZONE)

ZONE 8

ZONE 4

4.7K

4.7K

End of Line Resistor

10K

End of Line Resistor

Zc1004: 4 Zones, 1 Sound outputZC1008: 8 Zones, 2 Sound outputZC1016: 16 Zones, 4 Sound output

SOUND+

SOUND-

Remote LED Remote LED Remote LED Remote LED Remote LED

Max. 25 detectorsin One Zone

Max. 5 to 10 (1A@24VDC) Sounder & Bell

in One Sound Output

Magnetic Door Contact

AC Power Input(90-270V)

HOT

NEUTRAL

GROUND

End of Line Resistor

SmokeDetector

HeatDetector

Smoke & HeatDetector

SmokeDetector

HeatDetector

ManualCall Point

SmokeDetector

ManualCall Point

SmokeDetector

HeatDetector

Bell Bell Sound StrobeSoundStrobe

SoundStrobe

Auxiliary DC28V output

NO

COM

DC24+DC24-

ZONE+

ZONE-

ZONE+

ZONE-

ZONE 1

ZONE 16

SOUND 1(Alarm Zone1)

SO

UN

D2

(Ala

rm Z

one2

)

ZONE 8

ZONE 4

4.7K

4.7K

End of Line Resistor

10K

End of Line Resistor

Zp1004: 4 Zones, 2 Sound outputZP1008: 8 Zones, 2 Sound outputZP1012: 12 Zones, 2 Sound outputZP1016: 16 Zones, 2 Sound output

SOUND+

SOUND-

Remote LED Remote LED Remote LED Remote LED Remote LED

Max. 25 detectorsin One Zone

Max. 5 to 10 (1A@24VDC) Sounder & Bell

in One Sound Output

AC Power Input(90-270V)

HOT

NEUTRAL

GROUND

SOUND+

SOUND-

Bell Sound StrobeSoundStrobe

SoundStrobe

10K

End of Line Resistor

Max. 5 to 10 (1A@24VDC) Sounder & Bell

in One Sound Output

NCFault

Relay Output

Auxiliary2(Alarm)Relay Output

NO

COMNC

Auxiliary1(Alarm1)Relay Output

NO

COMNC

RS485 communication busAB

NO.1Repeater

NO.2Repeater

Max.NO.16

Repeater

DC

24+

DC

24-

A B

CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE

Page 8: Conventional Fire Alarm System Product Range Guidedoc.diytrade.com/docdvr/947747/45361884/1467893009.pdf · 2016. 7. 7. · Conventional Fire Alarm System Product Range Guide Date:

Co

nven

tio

nal P

rod

uct

20

EXPERT IN SAFETY ANDSECURITY TECHNOLOGY

Telephone: +86-(0)755-23015236Fax: +86-(0)755-23015236Email: [email protected]://www.zoanco.com

15

CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE

End of Line Resistor

SmokeDetector

HeatDetector

Smoke & HeatDetector

No.1 Slave Panel

SmokeDetector

HeatDetector

ManualCall Point

SmokeDetector

ManualCall Point

SmokeDetector

HeatDetector

Bell Bell Sound StrobeSoundStrobe

SoundStrobe

DC24V Power

RS485 Communication

DC24+

DC24-

AB

ZONE+

ZONE-

ZONE+

ZONE-

ZO

NE

1

ZO

NE

2

SO

UN

D O

UT

PU

T

4.7K

4.7K

End of Line Resistor

1N40

07D

iode

End of Line Diode

SOUND+

SOUND-

Remote LED Remote LED Remote LED Remote LED Remote LED

Max. 25 detectorsin One Zone

Max. 5 to 10 (1A@24VDC) Sounder & Bell

in One Sound Output

AC Power Input(90-270V)

HOT

NEUTRAL

GROUND

ZO

NE

1

ZO

NE

2

SO

UN

D O

UT

PU

T

ZO

NE

1

ZO

NE

2

SO

UN

D O

UT

PU

T

Max No.31 Slave Panel Master Panel

DC

24V

DC24V Power Supply

DC12Vbattery

DC12Vbattery

Fire

1 A

larm

Rel

ay O

utpu

tN

O

CO

M

Fire

2 A

larm

Rel

ay O

utpu

t

Fau

lt R

elay

Out

put

NO

CO

M

NO

CO

M

Fire

1 A

larm

Rel

ay O

utpu

tN

O

CO

M

Fire

2 A

larm

Rel

ay O

utpu

t

Fau

lt R

elay

Out

put

NO

CO

M

NO

CO

M

Fire

1 A

larm

Rel

ay O

utpu

tN

O

CO

M

Fire

2 A

larm

Rel

ay O

utpu

t

Fau

lt R

elay

Out

put

NO

CO

M

NO

CO

M

DC24+

DC24-

ABRS485 Communication

DC24V Power


Recommended