Copyright © 2014 EMC Corporation. All Rights Reserved. Data Mover Failover Upon completion of this module, you should be able to: Data Mover Failover Test Data Mover Failover and Failback Data Mover Failover 1
Transcript

Copyright © 2014 EMC Corporation. All Rights Reserved.

Data Mover Failover

Upon completion of this module, you should be able to:• Data Mover Failover• Test Data Mover Failover and Failback

Data Mover Failover 1

Copyright © 2014 EMC Corporation. All Rights Reserved.

Data Mover Failover

Lesson 1: Data Mover Failover

Data Mover Failover 2

During this lesson the following topics are covered:• The failover process and policies• Standby Data Movers• Planning and Configuring Data Mover failover

Copyright © 2014 EMC Corporation. All Rights Reserved.

Failover Process

• Primary Data Mover (DM) fails• Designated Standby Data Mover is activated as a spare

Requires identical network configuration

Data Mover Failover 3

Standby Data Mover Primary Data Mover

Copyright © 2014 EMC Corporation. All Rights Reserved.

Data Mover failure detection

• Failover occurs under any of these conditions Data Mover panic: A hardware or software faults Data Mover hang: A condition that leads to both internal down Failover failure: Failure during a failover operation. Spontaneous Data Mover reset

• Failover does not occur under these conditions Manually restarting a Data Mover Removing a Data Mover its slot Network Failure

Data Mover Failover 4

Copyright © 2014 EMC Corporation. All Rights Reserved.

How Data Mover Failover Works

• Normal operations Control Station constantly

monitors all Data Movers (DM)• When Primary DM fails

Control Station instructs Standby to take over

Standby resumes entire identity and all production services

Original Primary goes into failed state

• After problem is resolved Administrator manually initiates

restoration of original Primary

Data Mover Failover 5

FAILED Primary Data Mover

Control Station

“Go!”

Primary Data Mover Standby Data Mover

Control Station

Monitor

Primary Data Mover Standby Data Mover

Control Station

MonitorRestore

Copyright © 2014 EMC Corporation. All Rights Reserved.

Standby Data Mover

• Hot-spare for Primary Data Movers• Can act as a spare for up to 7 primaries (depending on model)

Recommended ratio is at least one Standby for three primaries

• For the highest availability, use 1:1 ratio• On a two Data Mover VNX, server_3 is pre-configured as a

Standby for server_2• VNX OE software is the same for all hardware platforms

Data Mover Failover 6

Copyright © 2014 EMC Corporation. All Rights Reserved.

Failover Policies

• Pre-determined action• Invoked by the Control Station when it detects a failover

condition• Policy types

Auto Retry Manual

Data Mover Failover 7

Copyright © 2014 EMC Corporation. All Rights Reserved.

Planning for Data Mover Failover

• Determine Primary and Standby Data Movers Ensure Primaries and Standbys have the same network hardware

components Standbys are free of any configurations

• Switch ports of the Standby Data Movers are assigned to the same VLANs as the Primary• Ethernet Jumbo frame configuration related to Primary Data

Mover ports are in place for the Standby Data Mover• Network configuration must be identical

Speed/Duplex LACP / Link aggregation Fail Safe Networking (FSN)

Data Mover Failover 8

Copyright © 2014 EMC Corporation. All Rights Reserved.

Failover Configuration

Data Mover Failover 9

• To configure server_3 as the Standby for server_2:

1. Select System > Hardware > Data Movers

2. Select the Data Mover, and click Properties.

3. Set Standby Movers to server_3

4. Failover Policy, auto5. Click Apply

Server role

Failover policy

Standby DM

Copyright © 2014 EMC Corporation. All Rights Reserved.

Data Mover Failover

During this lesson the following topics were covered:• The failover process and policies• Standby Data Movers• Planning and Configuring Data Mover failover

Lesson 1: Summary

Data Mover Failover 10

Copyright © 2014 EMC Corporation. All Rights Reserved.

Data Mover Failover

During this lesson the following topics are covered:• Testing Data Mover failover• Restoring a Data Mover• Deleting a Data Mover failover relationship

Lesson 2: Testing Data Mover Failover and Failback

Data Mover Failover 11

Copyright © 2014 EMC Corporation. All Rights Reserved.

Data Mover Failover Testing Considerations

• Test Data Mover failover periodically/regularly (e.g. Quarterly)• Perform test at low/no impact times• When testing, validate the following

Standby assumes the identity of Primary VLAN membership and LACP configuration User access to:

File systems Shares Home directories

Data Mover Failover 12

Copyright © 2014 EMC Corporation. All Rights Reserved.

Testing Data Mover Failover

• Run the following CLI Command to manually activate the Standby Data Mover

server_standby <primary_DM> –activate mover

Data Mover Failover 13

Copyright © 2014 EMC Corporation. All Rights Reserved.

Restoring a Data Mover After Failover

System > Hardware > Data Movers• Select Data Mover to restore and click Restore

Data Mover Failover 14

Copyright © 2014 EMC Corporation. All Rights Reserved.

Deleting a Failover Relationship

• To delete Standby relationship: Hardware → Data Movers > Server_x → uncheck field Standby Movers

Data Mover Failover 15

• To change Data Mover from Standby to Primary: Hardware → Data Movers → server_x → select Role: Primary

Copyright © 2014 EMC Corporation. All Rights Reserved.

Data Mover Failover

During this lesson the following topics were covered:• Testing Data Mover failover• Restoring a Data Mover• Deleting a Data Mover failover relationship

Lesson 2: Summary

Data Mover Failover 16

Copyright © 2014 EMC Corporation. All Rights Reserved.

Summary

Key points covered in this module:• Successful Data Mover failover requires careful planning of

network switch and port configurations• Test plans should include validating access to VNX resources:

File systems Shares Home directories

Data Mover Failover 17

Copyright © 2014 EMC Corporation. All Rights Reserved.

Course Summary

Key points covered in this course:• Configuration of Unisphere Security and Features• Configuration and management of VNX block access for open

systems hosts (Linux, Windows and VMware ESXi) • Configuration and management of VNX file access for Windows

and Linux user/application environments via NFS and CIFS environments• Configuration of VNX local replication in block and file

environments

18Data Mover Failover