Åsa Wahlström, Passivhus Norden 2013 Cost optimal energy efficiency in multifamily houses Åsa Wahlström Peter Filipsson Catrin Heincke CIT Energy Management
Transcript

Åsa Wahlström, Passivhus Norden 2013

Cost optimal energy 

efficiency in multifamily houses

Åsa WahlströmPeter FilipssonCatrin Heincke

CIT Energy Management

Åsa Wahlström, Passivhus Norden 2013

Other

Natural gas

Electricity

Oil

District heating

Year of construction

Åsa Wahlström, Passivhus Norden 2013

0

100000

200000

300000

400000

500000

600000

700000

800000

Num

ber o

f apa

rtmen

ts

Year of construction

Sluten kvartersbebyggelseoch övriga flerbostadshus

Lamellhus

Punkthus

Loftgångshus

Flerbostadsvillor m.m.

Slab block

Tower blocks

Houses with external galleries

Other

Källa: Så byggdes husen 1880 - 2000, femte upplagan. C. Björk, P. Kallstenius & L. Reppen (2003)

Small apartment buildings

Åsa Wahlström, Passivhus Norden 2013

Recast of the European Energy Performance of 

Building Directive

Member states should state energy performance requirements for:

• nearly zero‐energy buildings (nZEB) for new constructions– public buildings 2019– all buildings 2021

• minimum requirements when buildings undergo a major renovation – to the extent that this is technically, functionally and economically feasible

Åsa Wahlström, Passivhus Norden 2013

1 January 2013Reconstruction requirements in the building regulations

The basis for quality requirements that should be applied during major renovation are the same as the ones at new construction

Åsa Wahlström, Passivhus Norden 2013

Building

Yearly energy use for heating, comfort cooling, domestic hot water, and electricity for operation of the building’s services systems. (kWh/m2)

Climate zon

I II III

Residential buildings with heating systems other than electric heating 

130 110 90 

Residential buildings with  electric heating

95 75 55

New construction requirements in 2013

Åsa Wahlström, Passivhus Norden 2013

• Low-rise Apartment Buildings

• Tower Blocks • High-rise Blocks

of Flats • Small Multi-

dwelling Building

•Climate zone III•Climate zone II•Climate zone I

• 1950-1960• 1961-1975

Åsa Wahlström, Passivhus Norden 2013

MeasuresMeasures addressing electricity use for shared services in the building Measures addressing domestic hot water provision Loft insulationWindow replacementFaçade insulationHeat recovery  

Heating system

requirements climate zone 3(kWh/m2)

Keep district heating

90

Install groundsource heat pump

55

Install air to water heat pump

55

Exhaust air heat pump (max 10 W/m2)

90

Åsa Wahlström, Passivhus Norden 2013

Example of Low‐rise apartment buildings climate zone 3, built 1950‐1960

2000

2100

2200

2300

2400

2500

2600

2700

2800

2900

3000

0 50 100 150

Presen

t value

 of life

 cycle 

cost [kr/m

2 ]

Energy use [kWh/m2year]

Districtheating

Groundsource heatpumpAir to waterheat pump

Exhaust airheat pump

BBR requirements

Åsa Wahlström, Passivhus Norden 2013

2000

2100

2200

2300

2400

2500

2600

2700

2800

2900

3000

0 50 100 150

Presen

t value

 of life

 cycle 

cost [kr/m

2 ]

Energy use [kWh/m2year]

Districtheating

Groundsource heatpumpAir to waterheat pump

Exhaust airheat pump

BBR requirements

Facade insulation

Windowreplacement

Åsa Wahlström, Passivhus Norden 2013

2000

2100

2200

2300

2400

2500

2600

2700

2800

2900

3000

0 50 100 150

Presen

t value

 of life

 cycle 

cost [kr/m

2 ]

Energy use [kWh/m2year]

Districtheating

Groundsource heatpumpAir to waterheat pump

Exhaust airheat pump

BBR requirements

Heat recovery

Åsa Wahlström, Passivhus Norden 2013

2000

2100

2200

2300

2400

2500

2600

2700

2800

2900

3000

0 50 100 150

Presen

t value

 of life

 cycle 

cost [kr/m

2 ]

Energy use [kWh/m2year]

Districtheating

Groundsource heatpumpAir to waterheat pump

Exhaust airheat pump

BBR requirements

Hot Water Measures

Åsa Wahlström, Passivhus Norden 2013

2000

2100

2200

2300

2400

2500

2600

2700

2800

2900

3000

0 50 100 150

Presen

t value

 of life

 cycle 

cost [kr/m

2 ]

Energy use [kWh/m2year]

Districtheating

Groundsource heatpumpAir to waterheat pump

Exhaust airheat pump

BBR requirements

Åsa Wahlström, Passivhus Norden 2013

Pres

ent v

alue

of li

fe c

ycle

cost

(SEK

/m2)

13100

52 49 5314

11151

Heatingsystem

Energy cost

Measures

Districtheating

Groundsource

heat pump

Air to water heat pump

Exhaust air heat pump

Existing building

Åsa Wahlström, Passivhus Norden 2013

Limitations• results are for typically buildings and may differ greatly in particular cases

• the energy savings fully fund the measures – renovation costs of maintenance purposes have not been considered

Åsa Wahlström, Passivhus Norden 2013

Conclusions• It is technologically possible to fulfill the building regulation requirements

• The four heating packages are competitive with each other

• Depending on predicts on energy prices and inflation in the future it may be one or the other option that is the most advantageous

Åsa Wahlström, Passivhus Norden 2013

Questions?

Åsa Wahlströ[email protected]

Thanks for financial support  

Thank you!