RTO 51178 andRTO 52698
COURSEBROCHURE
UEE42611
CERTIFICATE IV IN HAZARDOUS AREAS
- ELECTRICAL
15 Years ofVocational
Training Experience
† Career Oriented
† Affordable
† Nationally Recognised
Project Management Vision
$
† To undertake work on Electrical Equipment in Hazardous Areas (EEHA) that meets the requirements of AS/NZS 60079.14 and AS/NZS 60079.17.
† To read Ex rated equipment Name plate and Certificate of Conformity
† To select, install, test, maintain and inspection Ex equipment † To make an Ex d Barrier Gland† To obtain isolations, test and undertake detailed inspection of Ex installation
OBJECTIVES
OUTCOME
SCOPE
TARGETWORKFORCE
Full qualification – UEE42611 Certificate IV in Hazardous Areas- ElectricalStudents who hold an unrestricted electrical license issued by a state or Territory and are successfully competent in both theoretical and practical training, completing all units of competency in the training package (refer http://training.gov.au/Training/Details/UEE42611), will receive the full qualification.
This qualification provides competencies to select, install, test, maintain and inspect electrical equipment in hazardous areas (EEHA) in a gas and dust atmospheres. It includes ERAC requirements for an 'Electrician's licence'.
This course is for electrical workers involved in the “hands-on” side of hazardous area electrical work, i.e. the installation, maintenance or inspection of hazardous area electrical equipment. Electricians and instrument technicians are the most common attendees, but we also train electrical engineers who perform inspections as part of their role. The course covers the theory and practice of field work in hazardous areas. PRE-REQUISITESThe course is post-trade training, so we require a current unrestricted electrical license (any Australian state or territory) or instrumentation trade certificate as a pre-requisite. Electrical engineers meet the pre-requisites for the inspection related units only.
LOCATION
Delivered at one of PMV's national training centres (Perth, Brisbane and Adelaide), or at a client's facility
CERTIFICATE IV IN HAZARDOUS AREAS- ELECTRICAL
UEE42611
COURSE DURATION LOCATION6 Days
COURSE COST$ 2,550 Training centers at
Perth, Brisbane, Adelaide,or at Client's facility
08 9317 2146 [email protected] www.pmv.net.au
Project ManagementVision
REFRESHERTRAINING
TRAININGMETHOD
TRAININGCONTENT
COURSE STRUCTURE
WHY PMV?
In accordance with the AS/NZS 60079.14 requirement for continuing education, PMV recommends that the EEHA Installation and Maintenance competencies are refreshed every 3 years.
Blended delivery of 60% theory and 40% practical training with equipment that you are likely to see in a typical industrial environment with electrical equipment in hazardous areas (EEHA). The course includes in-class progressive assessment; short answer tests on hazardous area fundamentals; equipment marking; equipment certification; and, device interpretation.
You will undergo one on one practical training with industry experienced, qualified Electrical Professional Trainers with hands on experience in installation, inspection and remediation work in Hazardous areas. The training will include inspection on the purpose-built hazardous areas skids in the following areas:1. Principles of hazardous area classification;2. Explosion-protection techniques;3. Hazardous area standards and Codes of practice4. Reading and understanding hazardous area classification drawings5. Name plate reading exercise for Ex e, Ex n, Ex d, Ex i, Ex m, Ex t techniques;6. Reading Certificate of Conformity;7. Specific installation requirements for different types of Ex techniques;8. Equipment selection, installation, breakdowns and maintenance
requirements;9. permit to work and safe isolations and testing;10. Making up of Ex d Barrier Gland; and11. Visual/ Close/ Detailed inspection at PMV Training Bays (or at site on as
installed equipment) for Ex d, Ex i and Ex e and list the required remedialactions.
PMV offers a small size class with flexible training to accommodate difficult rosters / work schedules.
CERTIFICATE IVIN HAZARDOUS AREAS
- ELECTRICAL
08 9317 2146 [email protected] www.pmv.net.au
† Contextualised courses (6 days face to face)† Training is aligned to the requirements of latest IEC/AS/NZS 60079.14:2017,
60079.17:2017 and AS/NZS 4761.† All the courses have been developed in consultation with industry experts† You will undergo one on one practical training with industry experienced,
qualified Hazardous Area and Electrical Professional Trainers
Project ManagementVision
08 9317 2146 [email protected] www.pmv.net.au
UEENEEE038B
UEENEEE124A
UEENEEE117A
UEENEEK145A
UEENEEM080A
UEENEEE101A
UEENEEE102A
UEENEEE104A
UEENEEE105A
UEENEEE107A
UEENEEE137A
UEENEEG006A
UEENEEG033A
UEENEEG063A
UEENEEG101A
UEENEEG102A
UEENEEG103A
UEENEEG104A
UEENEEG105A
UEENEEG106A
UEENEEG107A
UEENEEG108A
UEENEEG109A
PMV Training
PMV Training
PMV Training
PMV Training
PMV Training
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Electrical License
Participate in development and follow a personal competency development plan
Compile and produce an energy sector detailed report
Implement and monitor energy sector OHS policies and procedures
Implement and monitor energy sector environmental and sustainable policies and procedures
Report on the integrity of explosion-protected equipment in a hazardous area
Apply Occupational Health and Safety regulations, codes and practices in the workplace
Fabricate, assemble and dismantle utilities industry components
Solve problems in d.c. circuits
Fix and secure electrotechnology equipment
Use drawings, diagrams, schedules, standards, codes and specifications
Document and apply measures to control OHS risks associated with electrotechnology work
Solve problems in single and three phase low voltage machines
Solve problems in single and three phase low voltage electrical apparatus and circuits
Arrange circuits, control and protection for general electrical installations
Solve problems in electromagnetic devices and related circuits
Solve problems in low voltage a.c. circuits
Install low voltage wiring and accessories
Install appliances, switchgear and associated accessories for low voltage electrical installations
Verify compliance and functionality of low voltage general electrical installations
Terminate cables, cords and accessories for low voltage circuits
Select wiring systems and cables for low voltage general electrical installations
Trouble-shoot and repair faults in low voltage electrical apparatus and circuits
Develop and connect electrical control circuits
Core Competency Standard UnitsAll Core competency standard units to be achieved Delivery Method
CERTIFICATE IVIN HAZARDOUS AREAS
- ELECTRICAL
UEENEEM020A
UEENEEM021A
UEENEEM022A
UEENEEM024A
UEENEEM025A
UEENEEM026A
UEENEEM028A
UEENEEM029A
UEENEEM030A
PMV Training
PMV Training
PMV Training
PMV Training
PMV Training
PMV Training
PMV Training
PMV Training
PMV Training
Attend to breakdowns in hazardous areas - gas atmospheres
Attend to breakdowns in hazardous areas - dust atmospheres
Attend to breakdowns in hazardous areas - pressurisation
Install explosion-protected equipment and wiring systems - gas atmospheres
Install explosion-protected equipment and wiring systems - dust atmospheres
Install explosion-protected equipment and wiring systems – pressurisation
Maintain equipment in hazardous areas - gas atmospheres
Maintain equipment in hazardous areas - dust atmospheres
Maintain equipment in hazardous areas - pressurisation
Group B – Qualification Elective Units Delivery Method
Project ManagementVision
UEENEEM039A
UEENEEM040A
UEENEEM041A
UEENEEM042A
UEENEEM044A
UEENEEM045A
UEENEEM046A
PMV Training
PMV Training
PMV Training
PMV Training
PMV Training
PMV Training
PMV Training
Conduct testing of hazardous areas installations — gas atmospheres
Conduct testing of hazardous areas installations — dust atmospheres
Conduct testing of hazardous area installations - pressurisation
Conduct visual inspection of hazardous areas installations
Conduct detailed inspection of hazardous areas installations - gas atmospheres
Conduct detailed inspection of hazardous areas installations - dust atmospheres
Conduct detailed inspection of hazardous areas installations - pressurisation
Group C – Qualification Elective Units Delivery Method
[email protected] www.pmv.net.au
CERTIFICATE IVIN HAZARDOUS AREAS
- ELECTRICAL
Project ManagementVision
Project ManagementVision
Perth10/22 Shields Crescent Booragoon, WA 6154, Perth.Tel: (08) 9317 2146 and (08) 9317 2147
BrisbaneUnit 14, 720 MacArthur Ave Central, Pinkenba, QLD, 4008 Tel: (07) 3255 5952
Adelaide1042 Port Road, Albert Park, SA, 5014Tel: (08) 9317 2147