+ All Categories
Home > Documents > Cover Air Conditioners 50Hz - Frigo-kor

Cover Air Conditioners 50Hz - Frigo-kor

Date post: 30-Nov-2021
Category:
Upload: others
View: 4 times
Download: 0 times
Share this document with a friend
11
Midea Is Your Idea Midea Air Conditioners 2007 Commercial Aircon System 50HZ GD Midea Commercial Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong, 528311, P.R.China Tel: +86-757-26339642 Fax: +86-757-26339337 E-mail: [email protected] Http: //www.midea.com.cn Http: //www.mdvchina.com (customer service)
Transcript
Page 1: Cover Air Conditioners 50Hz - Frigo-kor

Midea Is Your Idea

Midea Air Conditioners

2007

Commercial Aircon System 50HZ

GD Midea Commercial Air-conditioning Equipment Co., Ltd.

Add: Midea Industrial City, Shunde, Foshan, Guangdong, 528311, P.R.China

Tel: +86-757-26339642 Fax: +86-757-26339337

E-mail: [email protected]

Http: //www.midea.com.cn

Http: //www.mdvchina.com (customer service)

Page 2: Cover Air Conditioners 50Hz - Frigo-kor

N433

E U ROV EN TCERTIFIED PERFORMANCE

TUV Rheiniand Group Production inspected

L I S T E D

TUV Rheiniand

gepruftesicherheit

NRTL/CISO 14001: 1996

Certificate No.:CC1417

068

CERTIFIEDCOMPANYCERTIFIED

COMPANY

ISO 9001 : 2000Certificate No.: CC 454

068

I NTERN AT IONAL CONFORMI TY C ERT I F ICAT I

ONPR

OGRA

MSAUDI ARABIAN STANDARDS ORGANIZAT

ION

Midea produced its first Air

Conditioner in 1984. Currently

we are the industry leader for Air

conditioner manufacturing and

export . Midea has been

exporting Air Conditioners for the

last 16 years, and during this

time has cultivated strong

partnerships with hundreds of

overseas companies.

Our vertically integrated supply

chain al lows us to achieve

maximum efficiency in production

and product development.

We provide Global technical

training and a comprehensive

online customer service. All

of our customers from over

110 countries and regions

receive top quality service at

all times.

Midea Creates A Better Life

geprufteSicherheit

..

1 2

The year of 1999 has witnessed

Midea's entry into the field of

commercial air conditioner. The

leading-edged technology, state-of-

art assembly lines, and years' of

experience in air conditioner field have

made Midea as the leader in the field

of commercial air conditioner in China.

Nowadays, Midea can offer the

fullest range of commercial air

conditioner in China. It consists

of Multi Digital Variable System:

Digital scroll A/C system, Inverter

commercial A/C system; Light

Chiller System: Mini air-cooled

chiller system, Modular air-cooled

chiller system, Water-cooled

Packaged unit, Heating water

system; Commercial Chiller

System: Screw chiller system,

Centrifugal chiller system.

Page 3: Cover Air Conditioners 50Hz - Frigo-kor

Intelligent Manager is an integrated building management system(BMS) that uses our independent, high-speed

multi-transmission method. It has a centralized controller function that can perform high-speed centralized control

of our commercial A/C for buildings.

MDV system has various control solutions: Individual control, Group control, Network control, etc.

1 computer can monitor max 16 central controllers.

1 central centroller can monitor max 64 indoor units.

1 computer can monitor max 1024 indoor units.

Free combination, wide range5 basic modules, which can be freely assembled.

2HP increments of capacity range, which meets customers' needs accurately;

Maximum capacity is 64HP.

3 4

Friendly Refrigerant, save energy and protect environment

Good performance of cooling & heating.

The component of the R410A is close to azeotropy, with little change of the component

structure, the capability will not decrease during the recharge period.

Do not contain the element Chlorine, protect the ozonosphere

Feature of R410A system

Basic modules 5 basic modules: 8HP, 10HP, 12HP, 14HP, 16HP

2HP increments of capacity

Intelligent Built-in Manager SystemFull Range of R410A Digital Scroll A/C System

R410A

Max=64

Central controller

Max=64

Max=16

Max=32

Lonwork

LON busover ethernet

R

BMS

Touch controller

Built-in manager system

Fire alarm Security

*Elevator*Pump*Lighting ...etc.

Power supply facility

Remote controller

R410A

Basic modules

50-64HP

8-16HP

18-32HP

34-48HP

Page 4: Cover Air Conditioners 50Hz - Frigo-kor

Group setting, simple and efficient.

One group consists of on-line A/Cs in different

Central controllers, maximum 1024 units.

One system can be set by 16 groups to manage

a huge A/C system. The

group setting can control

each on-line unit, unionize

them to be On / Off or

change the parameters. It's

so convenient and easy.

Schedule setting, no need to worry during the operation of A/C

With the advanced Schedule setting mode, the

PC can easily manage the daily work of A/C. The

system can set the weekly plan of A/C and operate

automatically in cycle.

Windows version

Operate directly on Windows interface; friendlier

interface makes its applicable range much wider.

Main functions includes load calculation, multi-

split and chilled water system selection, explicit

quotation table output, hydraulic calculation,

capacity inquire with changeable outdoor

environment (for multi-split) or nonstandard

working criteria (for chiller), etc.

Update with product change.

CAD version Two versions each compatible with AutoCAD 2000/2002 and AutoCAD 2004/2005

Professional software that helps engineers design project easily, quickly and conveniently. Main

functions include load calculation, equipment selection, pipeline setting, system figure configuration,

quotation table automatic output, refrigerant volume calculation, wiring and installation diagram

output, etc.

Update with product change

5 6

Model selection softwareIntelligent Built-in Manager System

Independent Calculating System

Coverter

Digital Ammeter

CCM

Built-in manager system

CCM

Max=64

POWERPOWERPOWER

POWER

Independent calculation Report

Independent calculation and output with report, easy to know the charge of the A/C.

Page 5: Cover Air Conditioners 50Hz - Frigo-kor

DC(AC) Inverter Multi AC Inverter Multi Eco

Multi Series

Split Wall-Mounted

Four-Way Cassette

Duct

2007 Midea Commercial A/C Model Line Up

[ D ] Digital Scroll A/C System

[ M ] Multi Variable A/C System

[ H ] Multi System

[ V ] Inverter A/C System (DC/AC)

25.2-180kW28-84kW14kW10kW

25.2-180kW16-18kW12-14kW8kW

26kW12kW

[ R ] Heating Water System

Accessories

35kW17.5kW9kW7kW

Multi Star

9 10

Four-cassette type(12.5kW)

Duct type(slim)(6kW)

Duct type(13kW)

High static pressure Duct type(13kW)

Four-cassette type(6kW)

53-62

63-6

768

-76

29-43

44-49

50-52

R410A R407C R22

R410A R22

R407C R22

R410A R407C R22

R407C R22

R410A R410AR410A

R410A R410A

R410A R407C

R410A R407C

Four-way cassette One-way cassette (compact)

High static

pressure duct

Wall-mountedFloor standing

Four-way cassette One-way cassette (compact)

High static

pressure duct

Wall-mountedFloor standing

Ceiling & Floor

Ceiling & FloorDuctLow static

pressure duct

DuctLow static

pressure duct

R22

Heat Recovery Ventilator Auxiliary Electric Heater Auxiliary Electric Heater

Page 6: Cover Air Conditioners 50Hz - Frigo-kor

Long pipe, wide height difference

No electromagnetic Disturbance

Operation Principle Of Digital Scroll Compressor

150m

50m

15m

the max.pipe length between indoor unit and outdoor unit

the max.height difference between indoor unit and outdoor unit

the max.height difference between indoor units

Advanced Oil Return Technology

Accurate Temperature Control

Constant T emperature

Temperature control accuracy of MDV: *0.5*

Temperature control accuracy of ordinary air conditioner: *3*

(Time)

Digital Scroll A/C System

33 34

The digital scroll compressor which utilizes the axial

compliant sealing technology precisely adjust the axial

moving range of the stator scroll pan. And there is an

additional connecting by-pass between the suction inlet

and the pressure bore at the floating sealing point of

axial stator.

When the PWM solenoid valve is open, the pressure in

the pressure bore is released. The pressure in the

compression bore is higher than that top of the stator,

then the stator axis of the compressor will move upward

a little. So high pressure bore and low pressure inlet is

connected and the unloading is achieved.

When the PWM solenoid valve is closed, two stators

engaged. Then the airproof and loading is achieved. The

compressor can adjust the ratio of ONs to OFFs freely

to control the refrigerant output of the compressor.

MDV Digital Scroll System causes no

electromagnetic disturbance, since the loading

and unloading of compressor are merely

mechanical movements. This special feature

makes the Digital Scroll System applicable to

telecommunication companies, power stations,

and all kinds of precise science labs.

A

Electromagnetic Comparison Between Digital And Inverter

0 1 2 3 4 5

5 th7 th

11 th13 th17 th19 th

E

M

W

Inverter EMC Standard Digital

Precise Science Lab CommunicationComputer Lab

TV & Radio Receiver Station

The Digital Scroll Compressor is in the state of loading or unloading. In the loading state, the full speed

operation of the compressor motor ensures the refrigerant has enough power to bring the oil back to the

compressor. In the unloading state, there is no oil moving out of the compressor since there is no refrigerant

output, the inertia of the refrigerant can also bring some oil back to the compressor.

Combining the electronic control and the mechanical control, the oil level controller keeps an appropriate

oil level in the compressor crankcase. Equipped with alarm system, it is applicable to both low-pressure

& high pressure oil cycling system.

Compared with the traditional

central air conditioning system,

MDV System can reach a 0.5

Degree Centigrade accuracy.

Digital scroll system is the only system that is free of oil separator

and oil recycling equipment. In the loading status, the speed

of the refrigerant is enough to move oil back to the compressor.In

the unloading status, no refrigerant pump out, no oil out of

compressor.

150m

50m15m

Page 7: Cover Air Conditioners 50Hz - Frigo-kor

Outdoor Unit

Cooling & Heating

Outdoor Unit

Digital Scroll A/C System

Outdoor Unit

35 36

8

10

12

14

16

8+10

10+10

10+12

10+14

10+16

12+16

14+16

16+16

10x2+14

10x2+16

10+12+16

10+14+16

10+16x2

12+16x2

14+16x2

16x3

12x3+14

12x3+16

12x2+14+16

12x2+16x2

10+16x3

12+16x3

14+16x3

16x4

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

42

44

46

48

50

52

54

56

58

60

62

64

13

16

16

16

20

20

20

20

20

20

20

32

32

32

32

32

40

40

40

40

40

50

50

50

50

50

64

64

64

MDV-D252W/CS(N2)(N1)

MDV-D280W/CS(N2)(N1)

MDV-D335W/CS(N2)(N1)

MDV-D400W/CS(N2)(N1)

MDV-D450W/CS(N2)(N1)

MDV-D532W/CS(N2)(N1)

MDV-D560W/CS(N2)(N1)

MDV-D615W/CS(N2)(N1)

MDV-D680W/CS(N2)(N1)

MDV-D730W/CS(N2)(N1)

MDV-D785W/CS(N2)(N1)

MDV-D850W/CS(N2)(N1)

MDV-D900W/CS(N2)(N1)

MDV-D960W/CS(N2)(N1)

MDV-D1010W/CS(N2)(N1)

MDV-D1065W/CS(N2)(N1)

MDV-D1130W/CS(N2)(N1)

MDV-D1180W/CS(N2)(N1)

MDV-D1235W/CS(N2)(N1)

MDV-D1300W/CS(N2)(N1)

MDV-D1350W/CS(N2)(N1)

MDV-D1405W/CS(N2)(N1)

MDV-D1455W/CS(N2)(N1)

MDV-D1520W/CS(N2)(N1)

MDV-D1570W/CS(N2)(N1)

MDV-D1630W/CS(N2)(N1)

MDV-D1685W/CS(N2)(N1)

MDV-D1750W/CS(N2)(N1)

MDV-D1800W/CS(N2)(N1)

Capacity(HP) Model Combination Indoor unit connected

Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.

R410A

R407C

R22

28.031.5

25.227.0

380,50,3

980x1630x8001040x1780x840

1751550

1000058

245260

1-drive-1314/28/28

SystemMatch Configuration

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxDPacking WxHxD

NetGross

kWkW

m3/hdB(A)

mmmm

kgkg

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

Piping Connection

CoolingHeatingElectrical Data

Max Length of pipeMax Height Difference Between indoor units Between indoor units and outdoor unit

MaxQty per 20'/40'/40'HQ

IMDV-D252W/CSN1 IMDV-D280W/CSN1 IMDV-D335W/CSN1 IMDV-D400W/CSN1 IMDV-D450W/CSN1

Pieces1-drive-16

33.535.0

40.043.0

396416

1400060

1380x1630x8301440x1800x860

45.047.0

1-drive-208/16/16

SystemMatch Configuration

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxDPacking WxHxD

NetGross

kWkW

m3/hdB(A)

mmmm

kgkg

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

Piping Connection

CoolingHeatingElectrical Data

Max Length of pipeMax Height Difference Between indoor units Between indoor units and outdoor unit

MaxQty per 20'/40'/40'HQ

IMDV-D252W/CS(N2) IMDV-D280W/CS(N2) IMDV-D335W/CS(N2) IMDV-D400W/CS(N2) IMDV-D450W/CS(N2)

Pieces

45.047.0

25.227.0

380,50,3

1380x1630x8301440x1800x860

1501550

1400060

327347

1-drive-138/16/16

28.031.5

1-drive-16

33.535.0

40.043.0

396416

1-drive-20

Page 8: Cover Air Conditioners 50Hz - Frigo-kor

Indoor UnitUnit:X100W

Cooling & Heating

Outdoor Unit

Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.

Outdoor Unit

Digital Scroll A/C System

Model Refrigerant Capacity

R410A R407C R22

R407C R22

R410A

R410A R407C R22

R410A R407C R22

R410A R407C R22

280

R410A R407C R22

R410A R407C R22

R410A R407C R22

R410A R407C R22

R410A R407C R22

R410A R407C R22

R410A R407C R22

R410A R407C R22

37 38

R407C

R22

Four-way cassette

Four-way cassette (compact)

High static pressure duct

One-way cassette

One-way cassette(compact)

Wall-mounted(compact)

Wall-mounted

High static pressure duct

Duct

Low Static PressureDuct

Floor Standing

Concealed Floor Standing

The Digital Scroll A/C System and Inverter Commercial A/C System have the same specification of indoor unit.

Ceiling & floor

R410A

997x1920x8801105x2120x1034

1000058

245260

IMDV-D100W/(S)N1 IMDV-D140W/SN1 IMDV-D280W/BSN1

28.031.5

1-drive-1610/20/20

1751550

Model

SystemMatch Configuration

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxDPacking WxHxD

NetGross

kWkW

m3/hdB(A)

mmmm

kgkg

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

Piping Connection

CoolingHeatingElectrical Data

Max Length of pipeMax Height Difference Between indoor units

Between indoor units and outdoor unit

MaxQty per 20'/40'/40'HQ Pieces

10.011.0

990x960x3601120x1090x435

60820

500054

101106

1-drive-650/100/100

14.016.0

220-240,50,1(380,50,3)

1-drive-830/62/62

600055

940x1245x3401058x1377x435

110125

380,50,3

IMDV-D100W/SN2 IMDV-D100W/(N2) IMDV-D140W/S(N2) IMDV-D280W/BS(N2) IMDV-D560W/BS(N2) IMDV-D840W/BS(N2)

14.016.0

380,50,3

1-drive-8

10.011.0

380,50,3

990x960x3601120x1090x435

60820

500054

101106

1-drive-650/100/100

SystemMatch Configuration

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxDPacking WxHxD

NetGross

kWkW

m3/hdB(A)

mmmm

kgkg

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

Piping Connection

CoolingHeatingElectrical Data

Max Length of pipeMax Height Difference Between indoor units

Between indoor units and outdoor unit

MaxQty per 20'/40'/40'HQ

500054

Pieces

220-240,50,1

997x1920x8801105x2120x1034

1000058

245260

28.031.5

1-drive-1610/20/20

1501550

56.064.0

2000060

1992x1920x8802110x2120x1034

520525

1-drive-204/10/10

84.095.0

2987x1920x8803105x2120x1034

3000062

780785

1-drive-322/6/6

Page 9: Cover Air Conditioners 50Hz - Frigo-kor

Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.

Indoor Unit (Q4)

Cooling & Heating

Digital Scroll A/C System

Indoor Unit (Q1)

Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.

Indoor Unit (T3)

Indoor Unit (T2)

39 40

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxD BodyPanel

Packing WxHxD Body Panel

Net Body/PanelGross Body/PanelQty per 20'/40'/40'HQ Indoor

kWkW

m3/hdB(A)

mmmmmmmm

kgkg

Pieces

V~,Hz,Ph

78036

2.83.2

580x254x580650x30x650795x340x745715x115x715

220-240,50,1

22/329/5

110/245/252

3.64.0

4.55.0

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

IMDV-D28Q4/ N1-A IMDV-D36Q4/ N1-A IMDV-D45Q4/ N1-AIMDV-D28Q4/(N2)-A IMDV-D36Q4/(N2)-A IMDV-D45Q4/(N2)-A IMDV-D28Q4/(N2) IMDV-D36Q4/(N2)

870

2.83.2

840x240x840950x40x950955x255x955

1030x145x1030

25/632/11

72/145/168

3.64.0

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxD BodyPanel

Packing WxHxD Body Panel

Net Body/PanelGross Body/PanelQty per 20'/40'/40'HQ Indoor

kWkW

m3/hdB(A)

mmmmmmmm

kgkg

Pieces

V~,Hz,Ph

105038

840x240x840950x40x950955x255x955

1030x145x1030

220-240,50,1

28/634/11

72/145/168

4.55.0

5.66.3

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

IMDV-D56Q4/N1 IMDV-D71Q4/N1 IMDV-D80Q4/N1 IMDV-D90Q4/N1 IMDV-D112Q4/N1 IMDV-D45Q4/(N2) IMDV-D56Q4/(N2) IMDV-D71Q4/(N2) IMDV-D80Q4/(N2) IMDV-D90Q4/(N2) IMDV-D112Q4/(N2)

7.18.0

42

8.09.0

9.010.0

840x310x840

955x325x955

160044

35/641/11

56/126/144

11.212.5

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net Body/PanelGross Body/PanelQty per 20'/40'/40'HQ Indoor

2.83.2

220-240,50,1

850x235x4001050x18x4701080x310x4601120x172x540

47035

23/427/7

115/238/268

kWkW

m3/hdB(A)

kgkg

Pieces

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

Net WxHxD BodyPanel

Packing WxHxD Body Panel

mmmmmmmm

3.64.0

50036

IMDV-D28Q1/B(N2) IMDV-D36Q1/B(N2) IMDV-D45Q1/B(N2) IMDV-D56Q1/B(N2) IMDV-D71Q1/B(N2)

31/938/12

69/145/165

4.55.0

1200x198x6551420x10x7551380x265x7751500x110x870

78042

5.66.3

7.18.0

1080

IMDV-D28Q1/BN1 IMDV-D36Q1/BN1 IMDV-D45Q1/BN1 IMDV-D56Q1/BN1 IMDV-D71Q1/BN1

Model

Voltage,Frequence,Phase

Air Flow VolumeExternal static pressure Noise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hPa

dB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph

5801034

2.22.6

955x210x3851114x277x469

1519

214/437/480

2.83.2

35

3.64.0

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

IMDV-D22T3/N1 IMDV-D28T3/N1 IMDV-D36T3/N1 IMDV-D45T3/N1 IMDV-D56T3/N1 IMDV-D22T3/(N2) IMDV-D28T3/(N2) IMDV-D36T3/(N2) IMDV-D45T3/(N2) IMDV-D56T3/(N2)

220-240,50,1

4.55.0

1301x210x3851459x277x469

1822

164/315/391

950

37

5.66.3

2.83.2

35

3.64.0

2.22.6

Model

Voltage,Frequence,Phase

Air Flow VolumeExternal static pressureNoise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hPa

dB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph 220-240,50,1

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

800x320x550930x420x755

2634

61/134/164

7504034

IMDV-D22T2/N1 IMDV-D28T2/N1 IMDV-D36T2/N1 IMDV-D45T2/N1-A3 IMDV-D56T2/N1-A3IMDV-D22T2/(N2) IMDV-D28T2/(N2) IMDV-D36T2/(N2) IMDV-D45T2/(N2)-A3 IMDV-D56T2/(N2)-A3

4.55.0

1000x298x8001200x370x930

1160

38

4654

60/140/164

5.66.3

7.18.0

14604042

4755

60/140/164

8.09.0

Model

Voltage,Frequence,Phase

Air Flow VolumeExternal static pressureNoise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hPa

dB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph 220-240,50,1

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

1000x298x8001200x370x930

IMDV-D71T2/N1-A3 IMDV-D80T2/N1-A3 IMDV-D90T2/N1-A3 IMDV-D112T2/N1-A3 IMDV-D140T2/N1-A3 IMDV-D280T2/N1 IMDV-D71T2/(N2)-A3 IMDV-D80T2/(N2)-A3 IMDV-D90T2/(N2)-A3 IMDV-D112T2/(N2)-A3 IMDV-D140T2/(N2)-A3 IMDV-D280T2/(N2)

9.010.0

1350x298x8001555x370x930

20707044

6070

48/100/112

11.212.5

14.016.0

2400

46

28.031.0

1350x450x7601600x700x1010

44009649

99109

22/48/48

Page 10: Cover Air Conditioners 50Hz - Frigo-kor

Digital Scroll A/C System

Indoor Unit (F)Indoor Unit (T1)

Indoor Unit (T1)

Cooling & Heating

41 42

Indoor Unit (F)

Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.

Cooling & Heating

Indoor Unit (DL)

Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.

80036

3.64.0

995x660x1981080x740x290

220-240,50,1

3037

128/270/300

7.18.0

100040

4.55.0

5.66.3

38

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hdB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

IMDV-D36DL/N1-B IMDV-D45DL/N1-B IMDV-D56DL/N1-B IMDV-D71DL/N1-B IMDV-D80DL/N1-B IMDV-D90DL/N1-B IMDV-D112DL/N1-B IMDV-D140DL/N1-BIMDV-D36DL/(N2)-B IMDV-D45DL/(N2)-B IMDV-D56DL/(N2)-B IMDV-D71DL/(N2)-B IMDV-D80DL/(N2)-B IMDV-D90DL/(N2)-B IMDV-D112DL/(N2)-B IMDV-D140DL/(N2)-B

120041

8.09.0

9.010.0

1400

1285x660x1981365x740x290

3442

99/203/228

11.212.5

180042

14.016.0

2000

1670x680x2401760x760x330

5262

72/153/168

Model

Voltage,Frequence,Phase

Air Flow VolumeExternal static pressureNoise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hPa

dB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph

11.212.5

14.016.0

28.031.5

5000

50

1350x450x7601600x700x1010

98108

22/48/48

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

IMDV-D71T1/(N2) IMDV-D80T1/(N2) IMDV-D90T1/(N2) IMDV-D112T1/(N2) IMDV-D140T1/(N2) IMDV-D280T1/(N2)

8.09.0

9.010.0

2200

47

1200x380x6601425x473x775

6270

60/123/123

130019644

7.18.0

850x380x6601075x473x775

220-240,50,1

4955

81/166/166

IMDV-D71T1/N1 IMDV-D80T1/N1 IMDV-D90T1/N1 IMDV-D112T1/N1 IMDV-D140T1/N1 IMDV-D280T1/N1

4.55.0

Model

Voltage,Frequence,Phase

Air Flow VolumeExternal static pressureNoise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hPa

dB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph 220-240,50,1

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

1000x298x8001200x370x930

3845

60/140/164

14007038

IMDV-D45T1/(N2)-A3 IMDV-D56T1/(N2)-A3 IMDV-D71T1/(N2)-A3 IMDV-D80T1/(N2)-A3 IMDV-D90T1/(N2)-A3 IMDV-D112T1/(N2)-A3 IMDV-D140T1/(N2)-A

5.66.3

7.18.0

1550

42

4047

8.09.0

9.010.0

215010044

5059

48/100/112

1350x298x8001555x370x930

11.212.5

14.016.0

250015046

7282

36/84/98

1350x320x8001555x440x930

IMDV-D45T1/N1-A3 IMDV-D56T1/N1-A3 IMDV-D71T1/N1-A3 IMDV-D80T1/N1-A3 IMDV-D90T1/N1-A3 IMDV-D112T1/N1-A3 IMDV-D140T1/N1-A

42035

2.22.6

1000x626x2201145x810x285

220-240,50,1

3842

80/168/252

2.83.2

3.64.0

62037

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hdB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

IMDV-D22F/N1 IMDV-D28F/N1 IMDV-D36F/N1 IMDV-D45F/N1 IMDV-D56F/N1 IMDV-D71F/N1 IMDV-D80F/N1 IMDV-D22F/(N2) IMDV-D28F/(N2) IMDV-D36F/(N2) IMDV-D45F/(N2) IMDV-D56F/(N2) IMDV-D71F/(N2) IMDV-D80F/(N2)

4.55.0

8.09.0

490

1200x626x2201335x810x285

4347

68/138/216

5.66.3

85039

1500x626x2201645x810x285

5560

54/114/171

95040

7.18.0

105042

42035

2.22.6

750x545x212835x630x265

220-240,50,1

3539

91/182/282

2.83.2

3.64.0

62037

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hdB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

IMDV-D22F/N1-A IMDV-D28F/N1-A IMDV-D36F/N1-A IMDV-D45F/N1-A IMDV-D56F/N1-A IMDV-D71F/N1-A IMDV-D80F/N1-A IMDV-D22F/(N2)-A IMDV-D28F/(N2)-A IMDV-D36F/(N2)-A IMDV-D45F/(N2)-A IMDV-D56F/(N2)-A IMDV-D71F/(N2)-A IMDV-D80F/(N2)-A

4.55.0

8.09.0

490

950x545x2121035x630x265

3944

73/155/236

5.66.3

85039

1250x545x2121335x630x265

5055

59/134/192

95040

7.18.0

105042

Page 11: Cover Air Conditioners 50Hz - Frigo-kor

Digital Scroll A/C System

Cooling & Heating

Indoor Unit (G)

Indoor Unit (G)

Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.

43

Inverter A/C System(DC/AC)

[ V ] Series

58034

2.22.5

790x265x195875x375x285

220-240,50,1

911

312/668/780

2.83.2

3.64.0

85037

920x292x2251015x368x295

1315

288/578/653

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hdB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

IMDV-D22G/N1-E IMDV-D28G/N1-E IMDV-D36G/N1-E IMDV-D45G/N1-E IMDV-D56G/N1-E IMDV-D22G/(N2)-E IMDV-D28G/(N2)-E IMDV-D36G/(N2)-E IMDV-D45G/(N2)-E IMDV-D56G/(N2)-E

4.55.0

5.66.3

56036

2.22.5

880x275x1981000x420x295

220-240,50,1

1114

252/512/576

2.83.2

3.64.0

67046

1080x330x2221315x445x320

1723

151/324/384

Model

Voltage,Frequence,Phase

Air Flow VolumeNoise Level

Net WxHxDPacking WxHxD

NetGrossQty per 20'/40'/40'HQ Indoor

kWkW

m3/hdB(A)

mmmm

kgkg

Pieces

V~,Hz,Ph

Capacity

Performance

Dimension

Weight

CoolingHeatingElectrical Data

IMDV-D22G/N1-A IMDV-D28G/N1-A IMDV-D36G/N1-A IMDV-D45G/N1-A IMDV-D56G/N1-A IMDV-D22G/(N2)-A IMDV-D28G/(N2)-A IMDV-D36G/(N2)-A IMDV-D45G/(N2)-A IMDV-D56G/(N2)-A

4.55.0

5.66.3


Recommended