+ All Categories
Home > Documents > COVER AND GATEFOLD SPECIFICATIONS - … (perfect bind jobs only) Special Considerations for Perfect...

COVER AND GATEFOLD SPECIFICATIONS - … (perfect bind jobs only) Special Considerations for Perfect...

Date post: 24-Apr-2018
Category:
Upload: phamtruc
View: 219 times
Download: 3 times
Share this document with a friend
5
COVER AND GATEFOLD SPECIFICATIONS Standard 4-page Cover -1- September 2012 edition DCOV]2 (inside front cover) DCOV]3 (inside back cover) 8-1/4" 8-1/4" 10-3/4" 10-3/4" DCOV]1 (outside front cover) DCOV]4 (outside back cover) 8-1/4" 8-1/4" INSIDE COVER OUTSIDE COVER All image must knockout for gluing Backbone Represents spine or backbone (depends on binding style) Safety margin Actual trim Bleed zone Hinge-score (perfect bind jobs only) Special Considerations for Perfect Bind Projects General Page Layout: Standard final trim is 8.25" x 10.75". Alternate sizes should be reviewed with your Customer Service Representative. Supplied files for perfect bind projects should have the covers created as “spreads” that equal the trim size of the front and back cover plus the backbone measurement supplied by your RRD representative. Example: An 8.25" x 10.75" final trim with 1 / 4" backbone would be 16.75" x 10.75" (17.25" x 11.25" if supplied as a PDF to accommodate bleed). Any insert pages with image that butts into the backbone also need to bleed at the spine to allow for grind-off in the perfect binding process. Standard backbone grind-off is 1 / 8", two-pass jobs (Flush Gates) require a 3 / 16" grind-off ( 1 / 16" for the first pass, 1 / 8" for the second pass). All inside front and back covers of perfect bind projects have 1 / 4" less live matter area than the physical dimensions. An 8.25" cover should be designed for elements to center on the first 8" while still maintaining the standard 1 / 4” safety margin at the face. The other 1 / 4" will be hidden by the hinge score. This also applies to the first and last body pages due to side glue application. Backbones: Backbones are necessary for any perfect bind projects. The width of the backbone is determined by page count and paper selection. The backbone area on the inside covers should be clear of any image or type (use a knockout equal to the size of the backbone). This is to allow for proper glue adhesion. You can create the backbone or we can create it for you. Please provide your CSR with detailed instructions on how it should print (blank, text, front cover image wrapping or back cover image wrapping). For assistance with any project requirements, contact your RRD Customer Service Representative or Sales Representative.
Transcript

COVER AND GATEFOLD SPECIFICATIONSStandard 4-page Cover

- 1 -September 2012 edition

DCOV]2(inside front cover)

DCOV]3(inside back cover)

8-1/4" 8-1/4"

10-3/4"10-3/4"DCOV]1(outside front cover)

DCOV]4(outside back cover)

8-1/4"8-1/4"

INSIDE COVEROUTSIDE COVER

All image m

ust knockout for gluing

Backbone

Represents spine or backbone (depends on binding style)Safety marginActual trimBleed zoneHinge-score (perfect bind jobs only)

Special Considerations for Perfect Bind ProjectsGeneral Page Layout:� Standard final trim is 8.25" x 10.75". Alternate sizes should be reviewed with your Customer Service Representative.� Supplied files for perfect bind projects should have the covers created as “spreads” that equal the trim size of thefront and back cover plus the backbone measurement supplied by your RRD representative.

� Example: An 8.25" x 10.75" final trim with 1⁄4" backbone would be 16.75" x 10.75" (17.25" x 11.25" if suppliedas a PDF to accommodate bleed).

� Any insert pages with image that butts into the backbone also need to bleed at the spine to allow for grind-off in theperfect binding process. Standard backbone grind-off is 1⁄8", two-pass jobs (Flush Gates) require a 3⁄16" grind-off (1⁄16" for thefirst pass, 1⁄8" for the second pass).� All inside front and back covers of perfect bind projects have 1⁄4" less live matter area than the physical dimensions. An8.25" cover should be designed for elements to center on the first 8" while still maintaining the standard 1⁄4” safetymargin at the face. The other 1⁄4" will be hidden by the hinge score. This also applies to the first and last body pages dueto side glue application.

Backbones:� Backbones are necessary for any perfect bind projects. � The width of the backbone is determined by page count and paper selection. � The backbone area on the inside covers should be clear of any image or type (use a knockout equal to the size of thebackbone). This is to allow for proper glue adhesion.� You can create the backbone or we can create it for you. Please provide your CSR with detailed instructions on how itshould print (blank, text, front cover image wrapping or back cover image wrapping).

For assistance with any project requirements, contact your RRD Customer Service Representative or Sales Representative.

COVER AND GATEFOLD SPECIFICATIONS6-page Gate Cover

- 2 -

GATE]3(inside front gate)

GATE]4(inside front cover) GATE]5(inside back cover)

10-3/4"

10-3/4"

INSIDE COVER

GATE]2(outside front gate)

GATE]1(outside front cover)

GATE]6(outside back cover)

OUTSIDE COVER

GATE]2(inside front cover)

GATE]3(inside back cover) GATE]4(inside back gate)

10-3/4"

10-3/4"

INSIDE COVER

GATE]1(outside front cover)

GATE]6(outside back cover)

GATE]5(outside back gate)

OUTSIDE COVER

Represents spine or backbone (depends on binding style)Safety marginActual trimBleed zoneHinge-score (perfect bind jobs only)

Standard Gate Flush GateFront Gate Back Gate Front Gate Back Gate

(2&3) (1&4) (5&6) (1&2) (3&6) (4&5) (2&3) (1&4) (5&6) (1&2) (3&6) (4&5)Saddlewire 8 8.125 8.25 8.25 8.125 8 8.125 8.25 8.25 8.25 8.25 8.125

Perfect 7.75 8.125 8.25 8.25 8.125 7.75 7.875 8.25 8.25 8.25 8.25 7.875

* All dimensions are based on a final trim of 81⁄4 x 103⁄4.

Notes:� The panel measurements for perfect bind jobs are necessary toaccommodate a hinge score and side glue.� On perfect bind jobs the IFC and IBC should be designed tocompensate for the 1⁄4" needed for the hinge score. For IFC, centeryour design on margins of 1⁄4" left and 1⁄2" on the right. For IBC,center your design on margins of 1⁄2" left and 1⁄4" on the right.� When designing your perfect bind panels remember to knock outthe backbone area. This is necessary to ensure proper glue adhesionduring the binding process.

Standard Gate Flush GateFolds 1/8" to 3/16" from face

to allow single pass trimming.Folds flush with face.

This double-binding pass also requires testing and extra manufacturing time.

Front Gate Cover Back Gate Cover

Panel measurements (inches)

COVER AND GATEFOLD SPECIFICATIONS8-page Gate Cover

- 3 -

GATE]2

(outside front gate)GATE]1

(outside front cover)

GATE]7(outside back gate)

10-3/4"

GATE]6(inside back gate)

GATE]8(outside back cover)

GATE]5(inside back cover)

GATE]3

(inside front gate)

10-3/4"

OUTSIDE COVER

INSIDE COVER

GATE]4(inside front cover)

Represents spine or backbone (depends on binding style)Safety marginActual trimBleed zoneHinge-score (perfect bind jobs only)

Front and Back Gate

Standard Gate Flush Gate(2&3) (1&4) (5&8) (6&7) (2&3) (1&4) (5&8) (6&7)

Saddlewire 8 8.125 8.125 8 8.125 8.25 8.25 8.125

Perfect 7.75 8.125 8.125 7.75 7.875 8.25 8.25 7.875

* All dimensions are based on a final trim of 81⁄4 x 103⁄4.

Notes:� The panel measurements for perfect bind jobs are necessary toaccommodate a hinge score and side glue.� On perfect bind jobs the IFC and IBC should be designed tocompensate for the 1⁄4" needed for the hinge score. For IFC, centeryour design on margins of 1⁄4" left and 1⁄2" on the right. For IBC,center your design on margins of 1⁄2" left and 1⁄4" on the right.� When designing your perfect bind panels remember to knock outthe backbone area. This is necessary to ensure proper glue adhesion during the binding process.

Panel measurements (inches)

Standard Gate Flush GateFolds 1/8" to 3/16" from face

to allow single pass trimming.Folds flush with face.

This double-binding pass also requires testing and extra manufacturing time.

COVER AND GATEFOLD SPECIFICATIONS8-page Gate Cover

- 4 -

GATE]3

(outside front gate)GATE]2

(outside front gate)

GATE]8(outside back cover)

10-3/4"

GATE]7(inside back cover)

GATE]1(outside front cover)

GATE]6(inside front cover)

GATE]4

(inside front gate)

10-3/4"

OUTSIDE COVER

INSIDE COVER

GATE]5(inside front gate)

Represents spine or backbone (depends on binding style)Safety marginActual trimBleed zoneHinge-score (perfect bind jobs only)

Standard Gate Flush Gate(2) (3) (5) (4) (1&6) (7&8) (2) (3) (5) (4) (1&6) (7&8)

Saddlewire 8 7.875 8 7.875 8.125 8.25 8.125 8 8.125 8 8.25 8.25

Perfect 7.75 7.625 7.75 7.625 8.125 8.25 7.875 7.75 7.875 7.75 8.25 8.25

* All dimensions are based on a final trim of 81⁄4 x 103⁄4.

Notes:� The panel measurements for perfect bind jobs are necessary toaccommodate a hinge score and side glue.� On perfect bind jobs the IFC and IBC should be designed tocompensate for the 1⁄4" needed for the hinge score. For IFC, centeryour design on margins of 1⁄4" left and 1⁄2" on the right. For IBC,center your design on margins of 1⁄2" left and 1⁄4" on the right.� When designing your perfect bind panels remember to knock outthe backbone area. This is necessary to ensure proper glue adhesion during the binding process.

Double Front Gate

Standard Gate Flush GateFolds 1/8" to 3/16" from face

to allow single pass trimming.Folds flush with face.

This double-binding pass also requires testing and extra manufacturing time.

Panel measurements (inches)

COVER AND GATEFOLD SPECIFICATIONS8-page Gate Cover

- 5 -

GATE]1

(outside front cover)GATE]8

(outside back cover)

GATE]6(outside back gate)

10-3/4"

GATE]5(inside back gate)

GATE]7(outside back gate)

GATE]4(inside back gate)

GATE]2

(inside front cover)

10-3/4"

OUTSIDE COVER

INSIDE COVER

GATE]3(inside back cover)

Represents spine or backbone (depends on binding style)Safety marginActual trimBleed zoneHinge-score (perfect bind jobs only)

Standard Gate Flush Gate(7) (6) (4) (5) (1&2) (3&8) (7) (6) (4) (5) (1&2) (3&8)

Saddlewire 8 7.875 8 7.875 8.25 8.125 8.125 8 8.125 8 8.25 8.25

Perfect 7.75 7.625 7.75 7.625 8.25 8.125 7.875 7.75 7.875 7.75 8.25 8.25

* All dimensions are based on a final trim of 81⁄4 x 103⁄4.

Notes:� The panel measurements for perfect bind jobs are necessary toaccommodate a hinge score and side glue.� On perfect bind jobs the IFC and IBC should be designed tocompensate for the 1⁄4" needed for the hinge score. For IFC, centeryour design on margins of 1⁄4" left and 1⁄2" on the right. For IBC,center your design on margins of 1⁄2" left and 1⁄4" on the right.� When designing your perfect bind panels remember to knock outthe backbone area. This is necessary to ensure proper glue adhesion during the binding process.

Double Back Gate

Standard Gate Flush GateFolds 1/8" to 3/16" from face

to allow single pass trimming.Folds flush with face.

This double-binding pass also requires testing and extra manufacturing time.

Panel measurements (inches)


Recommended