Issue Date: 2006-03-13 Page 1 of 3 Report Reference # E177343-A19-UL-2 Amendment 3 2006-11-20 Copyright © 2006 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment Product Category CCN: QQGQ2, QQGQ8 Test Procedure: Component Recognition Product: Power Supply for building-in Model/Type Reference: Flatpack2 A B C, Flatpack2 A B C BF Where A is the output power of the unit and can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank. B is the output voltage of the unit and can be 24V or 48V or blank, (For Flatpack2 A B C BF, "B" may only be 48V or blank) C can be any alphanumeric letters or blank for marketing purposes only. Rating(s): 1800 W units with 48V output: Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2000 W units with 48 V output: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A or 50 Vdc, 40 A 1800 W units with 24V output: N/A 2000 W units with 24 V output (Excluding model Flatpack2 A B C BF): Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output: 26.7 Vdc, 75 A Standards: UL 60950-1:2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 Applicant Name and Address: ELTEK ENERGY A/S GRAATERUDVEIEN 8 3036 DRAMMEN NORWAY
Transcript
Page 1: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 3 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Copyright © 2006

COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical

Business Equipment Product Category CCN: QQGQ2, QQGQ8 Test Procedure: Component Recognition Product: Power Supply for building-in Model/Type Reference: Flatpack2 A B C, Flatpack2 A B C BF

Where A is the output power of the unit and can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank. B is the output voltage of the unit and can be 24V or 48V or blank, (For Flatpack2 A B C BF, "B" may only be 48V or blank) C can be any alphanumeric letters or blank for marketing purposes only.

Rating(s): 1800 W units with 48V output: Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2000 W units with 48 V output: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A or 50 Vdc, 40 A 1800 W units with 24V output: N/A 2000 W units with 24 V output (Excluding model Flatpack2 A B C BF): Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output: 26.7 Vdc, 75 A

Standards: UL 60950-1:2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003

Applicant Name and Address:

ELTEK ENERGY A/S GRAATERUDVEIEN 8 3036 DRAMMEN NORWAY

Page 2: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 3 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Copyright © 2006

This Report includes the following parts, in addition to this cover page:

1. Specific Technical Criteria 2. Clause Verdicts 3. Critical Components 4. Test Results 5. Enclosures

Page 3: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 3 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Copyright © 2006

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. Test Report By: Reviewed By:

Casper S. Larsen Jan J. Jensen Associate Project Engineer Senior Project Engineer UL International Demko A/S UL International Demko A/S

Page 4: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Underwriters Laboratories Inc.

SPECIFIC TECHNICAL CRITERIA

UL 60950-1, First Edition Information technology equipment - Safety-

Part 1: General Requirements

Report Reference No........................: E177343-A19-UL-2 Compiled by .....................................: Casper S. Larsen Reviewed by ....................................: Jan J. Jensen Date of issue ....................................: 2006-03-13 Standards .........................................: UL 60950-1:2003, First Edition

CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 Test procedure .................................: Component Recognition Non-standard test method ...............: N/A Test item description .......................: Power Supply for building-in Trademark ........................................:

Model and/or type reference ............: Flatpack2 A B C, Flatpack2 A B C BF

Where A is the output power of the unit and can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank. B is the output voltage of the unit and can be 24V or 48V or blank, (For Flatpack2 A B C BF, "B" may only be 48V or blank) C can be any alphanumeric letters or blank for marketing purposes only.

Rating(s) ...........................................: 1800 W units with 48V output: Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2000 W units with 48 V output: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A or 50 Vdc, 40 A 1800 W units with 24V output: N/A

Page 5: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Underwriters Laboratories Inc.

2000 W units with 24 V output (Excluding model Flatpack2 A B C BF): Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output: 26.7 Vdc, 75 A

Particulars: test item vs. test requirements Equipment mobility .................................................... : for building-in Operating condition ................................................... : continuous Mains supply tolerance (%) ....................................... : +10%, -15% (according to manufacturer specification)Tested for IT power systems ..................................... : Yes IT testing, phase-phase voltage (V) .......................... : 230 Vac Class of equipment ................................................... : Class I (earthed) Mass of equipment (kg) ............................................ : 1.80 kg Protection against ingress of water ........................... : IP X0

Possible test case verdicts: - test case does not apply to the test object ............. : N / A - test object does meet the requirement ................... : Pass - test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent

national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

Page 6: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Underwriters Laboratories Inc.

GENERAL PRODUCT INFORMATION: CA1.0 Report Summary CA1.1 N/A

CB1.0 Product Description CB1.1 The equipment under test is a switch mode power supply, intended to be used in a rack system.

The power supply converts 230 Vac to 24 Vdc (nominal) or 48 Vdc (nominal) and communicates with a controller through its own microprocessor. The unit (in a rack system) is typically used to supply other telecommunication equipment, like mobile phone exchanges etc.

CC1.0 Model Differences CC1.1 The 48 V, 1800 W version uses main board 101148 and the 48 V, 2000 W version uses the main

board 206425. The two main boards are identical except for minor changes to the layout and component configuration. Flatpack2 24 V is identical to Flatpack2 2000W 48 V, except for the output rating, and minor changes in the secondary circuit. Flatpack2 24V uses main board 106969. Flatpack2 A B C BF is identical to Flatpack2 A B C except for reverse air flow, new fans, relocation of temperature sense (NTC201) from the controller board to the main board and change in value for Capacitor (C116) value changed from 220µF to 120 µF.

CD1.0 Additional Information CD1.1 See cover page for production sites.

The product was investigated to the following additional standards: EN 60950-1:2001 (which includes all European national differences, including those specified in this test report). Flatpack2 24: Max VA measurements. V=29.1 Vdc, A=85.2, VA=2009 (measured at 25.5 V, 78.8 A) Flatpack2 2000W 48 V: Max VA measurements. V=56.7 Vdc, A=41.2, VA=2016 (measured at 53.06 V, 38.0 A) Changes made under E177343-A19-CB-3 amendment 2 was performed under SMT program. Changes made under E177343-A19-CB-3 amendment 3 was performed under SMT program.

CE1.0 Technical Considerations CE1.2 The product was submitted and tested for use at the maximum ambient temperature (Tma)

permitted by the manufacturer’s specification of: 75 °C

Page 7: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Underwriters Laboratories Inc.

CE1.3 The means of connection to the mains supply is: through a connector on the backplane CE1.4 The product is intended for use on the following power systems: IT, TN CE1.5 The equipment disconnect device is considered to be: For building-in, must be determined in the

end product. CE1.7 The product was investigated to the following additional standards: EN 60950-1:2001 (which

includes all European national differences, including those specified in this test report). CE1.12 The following were investigated as part of the protective earthing/bonding: Printed wiring board

trace (refer to Enclosure - Pictures + Schematics + PWB for layouts) CE1.14 The following are available from the Applicant upon request: Specific data sheets for LEDs that

are used for indicating purposes and assumed to be inherently Class 1 operating in the 400 - 700 nm wavelength range., Installation (Safety) Instructions / Manual

CF1.0 Engineering Conditions of Acceptability CF1.1 For use only in or with complete equipment where the acceptability of the combination is

determined by Underwriters Laboratories Inc. When installed in an end-product, consideration must be given to the following:

CF2.0 The end-product Electric Strength Test is to be based upon a maximum working voltage of: 224 Vrms, 488 Vpk on Flatpack2 1800W 48V and 294Vrms, 568Vp for Flatpack2 2000W 48V and 270 Vrms, 690 Vp for Flatpack2 24V.

CF2.1 The following secondary output circuits are SELV: 48 V output for Flatpack2 1800W 48V and Flatpack2 2000W 48V. 24 V output for Flatpack2 24V.

CF2.2 The following secondary output circuits are at hazardous energy levels: 48 Vdc output (Flatpack2 1800W 48V, Flatpack2 2000W 48V), and 24 Vdc output (Flatpack2 24V).

CF2.3 The power supply terminals and/or connectors are: Suitable for factory wiring only CF2.4 The maximum investigated branch circuit rating is: 20 A CF2.5 The investigated Pollution Degree is: 2 CF2.6 The front bezel complies with the requirements for: 5V ratings CF2.7 Proper bonding to the end-product main protective earthing termination is: Required CF2.8 An investigation of the bonding terminals as protective earthing terminals has: Been conducted CF2.9 The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2

insulation system with the indicated rating greater than Class A (105°C): T200 and T201 (Class F).

CF3 The following end-product enclosures are required: Electrical, Fire

Page 8: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.7.1 Rated current (mA or A) ........................................ : 1800 W units with 48V output: Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2000 W units with 48 V output: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A or 50 Vdc, 40 A 1800 W units with 24V output: N/A 2000 W units with 24 V output(Excluding model Flatpack2 A B C BF): Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output: 26.7 Vdc, 75 A

Pass

Type/model or type reference ............................... : Flatpack2 A B C, Flatpack2 A B C BF Where A is the output power of the unit and can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank B is the output voltage of the unit and can be 24V or 48V or blank C can be any alphanumeric letters or blank for marketing purposes only.

Pass

1.7.8 Controls and indicators Pass 4.3.13.5 Laser class ............................................................ : LEDs provided for indicating

only and operate in the-

Page 9: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

wavelength range of 180 nm to 1 mm.

4.6.1 Dimensions (mm) .................................................. : Openings only provided in the rear and front side of the unit. Rear side: 18 openings each measuring 14x6.7 mm. Front side: Openings in front of fans, and 3 holes for indicating diodes.

-

4.7.2.2 Parts not requiring a fire enclosure N/A 5.1.6 Measured protective conductor current (mA) ........ : - - Max. allowed protective conductor current (mA) ... : - - A.1 Flammability test for fire enclosures of movable equipment having a total mass

exceeding 18 kg, and of stationary equipment (see 4.7.3.2) N/A

A.1.1 Samples................................................................. : -

Wall thickness (mm) .............................................. : - A.1.2 Conditioning of samples; temperature (°C) ........... : N/A A.1.3 Mounting of samples.............................................. : N/A A.1.4 Test flame N/A A.1.5 Test procedure N/A A.1.6 Compliance criteria N/A C Method of protection .............................................. : Protection by inherent or

external impedance. -

J Metal used ............................................................. : Copper alloy -

Page 10: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 7 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.5.1 TABLE: list of critical components Pass

Object/part No. Manufacturer/ trademark

type/model technical data Product Category CCN(s)

Required Marks of Conformity

Supplement ID

Common components in Flatpack2 familiy

- - - - -

Enclosure (Bottom) (mech/fire)

Various Metal min 1 mm thick - -

Enclosure (Top) (mech/fire)

Various Aluminum min 1.9 mm thick - -

Heat sink (left and Right side)

Various (metal material) min 5 mm thick. See enclosure for details.

- -

Front Bezel LG Chemical Ltd GN-5001TF 5V, min 1.5 mm thick. See enclosure for details.

QMFZ2 -

Face plate (Decorative part)

LG Chemical Ltd GN-5001TF HB, min 0.8mm thick. Tested according to HB75

QMFZ2 -

Capacitor (C100, C108) Arcotronics R.46 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Vishay F1772 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C103, C104, C138,C139)

Murata Type KH Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139) Alternate

Matsushita Type TS Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139)

Vishay WYO Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Page 11: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 8 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Alternate Capacitor (C103, C104, C138,C139) Alternate

Xiamen Faratronic MKP62 Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139) Alternate

TDK CS Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C142) Arcotronics R.41 Line-to-Earth; 250 V, 22 nF

FOKY2 UL

Capacitor (C142) Alternate

Evox Rifa PME271Y Line-to-Earth; 250 V, 22 nF

FOKY2 UL

Inductor (L100, L101) Eltek Energy AS 103293 or 106125 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L100) Alternate

Eltek Energy AS 106347 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L100) Alternate

Eltek Energy AS 208257 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Fuse (F100, F101) Littelfuse 324015 Rated: 250 V, 15 A

JDYX2 -

Fuseholder Ashadi Glass Matex Co., Ltd.

RG-40JA Rated V-0, Min. 1.0mm thick QMFZ2 UL

Fuseholder Alternate

Chevron Philips R-7 02 Rated V-0, Min. 1.0mm thick QMFZ2 UL

Varistor (VDR100) Epcos S14K420 420V (line-to-line) XUHT2 UL Relay (REL100) Various Various Contact rated:

250 V, 16 A

NLDX2 UL

Page 12: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 9 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Coil rated: 12 Vdc

Inductor (L102) Eltek Energy AS 106077 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L102) Alternative

Eltek Energy AS 101545 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Voltage Regulator (U100)

National Semiconductor

LM317AT Rated 1.2 - 37 V, 1.5 A

- -

Voltage Regulator (U100) Alternate

On Semiconductor LM317BT Rated 1.2 - 37 V, 1.5 A

- -

Transformer (T202) Eltek Energy AS 101543 Open type construction Class A insulation system Copper magnet winding wound on split bobbin See enclosure for details.

- -

Opto Coupler (ISO200, ISO201, ISO202)

Vishay TCLT1003 Double protection, provides 3750 Vac isolation

FPQU2 UL

Opto Coupler (ISO200, ISO201, ISO202) Alternate

Infineon SFH6156 (System H and J)

Double protection, provides 4420 Vac isolation

FPQU2 UL

Connector (CON 100) (Primary and SELV)

Elcon / Tyco 284-0472-15000C Rated: 250 V, 35 A

ECBT2, RTRT2 UL

Page 13: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 10 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Insulation between metal enclosure and PWB And above electrolytic capacitors

Dupont Melinex 226 Minimum 0.188 mm thick, rated VTM-2.

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Toray Lumirror S10 Minimum 0.188 mm thick, rated VTM-2.

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Dupont Nomex 410 Minimum 0.188 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-5BK Minimum 0.12 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-10 Minimum 0.25 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-17 Minimum 0.43 mm thick, rated V-0

QMFZ2 -

Page 14: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 11 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Insulation between Switch transistors/diodes and HeatSink

Pioneer Conductor Rubber

PMP-P-100 Min. 0.15mm thick, rated V-0, 150°C

QMFZ2 (E153203)

-

Insulation between Switch transistors/diodes and HeatSink Alternate

Pioneer Conductor Rubber

PMP-P-500A 0.16 – 0.18mm thick, rated V-0, 150°C

QMFZ2 (E153203)

-

Insulation between Switch transistors/diodes and HeatSink Alternate

Richain GTR-B (Made of material provide by Pioneer Conductor Rubber, type PMP-P-400)

Min. 0.42mm thick, rated V-0, 150°C

QMFZ2 (E153203)

-

Insulation between Switch transistors/diodes and HeatSink Alternate

Kunze KU 7-724/C45/CP(Made of material provide by Shin-Etsu Chemical Co., Ltd, type TC-45C)

Min. 0.42mm thick, rated V-0, 150°C

QMFZ2 (E48923) -

Insulation between Switch transistors/diodes and HeatSink Alternate

Kunze KU-KG2.5 (Made of material provide by E I DuPont, type Kapton 100MT)

Min. 0.025mm thick, rated V-0, 200°C

QMFZ2 (E39505) -

PWB Various Various Rated:V-0, 130°C ZPMV2 UL Components in Flatpack2 1800W 48V only

- - - - -

Page 15: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 12 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Transformer (T200, T201)

Eltek 105103 Open type construction Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

OBJY2 -

Fan (Two provided) Sanyo Denki 109P0412J3153 Rated: 16.3CFM 12 Vdc, 0.35 A

GPWV2 UL

Fan (Two provided) Alternate

Sunon PMO1204PQB1-A

Rated: 17.6 CFM 12 Vdc, 0.39 A

GPWV2 UL

Rectifier (DB100) Rectron RS1507M Rated min. 1000 V, 15 A - - Rectifier (DB100) Alternate

Wontop GBJ15M Rated min. 1000 V, 15 A - -

Diode (D104) Infineon SDT12S60 Rated min. 600 V, 12 A - - Electrolytic Capacitors (C110-C114, C200)

Various Various Rated: 450 V, 150 uF, 105 C

- -

Switch Transistor (Q103) Infineon Q67040-S4491 (SPW47N60C3)

Rated min. 600 V, 47 A - -

Page 16: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 13 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Switch Transistor (Q105) Fairchild FQA19N60 Rated min. 600 V, 19 A - - Switch Transistor (Q200, Q201)

Infineon SPW32N50C3 Rated min. 500 V, 32 A - -

Inductor (L200) Eltek 104697 Open type construction Copper magnet winding wound on bobbin See enclosure for details.

- -

Transformer (T100, T101)

Eltek 102620 Open type construction. Core: Ferrite. Outer diameter 17 mm, Inner diameter 9 mm, width 7 mm including coil. Coil: Triple insulated wire Furukawa Electric, Type: TEX-E. See enclosure for details.

- -

Electrolytic Capacitors (C211-C215, C217)

Various Various Rated: 63 V, 470 uF, 105 C

- -

Components in Flatpack2 2000W 48V and Flatpack2 2000W 48V BF only

- - - - -

Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Transformer (T200, Eltek 105103 Open type construction OBJY2 -

Page 17: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 14 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

T201) Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

Fan (Two provided, model Flatpack2 2000W 48V only)

Sanyo Denki 109P0412J3153 Rated: 16.3CFM 12 Vdc, 0.35 A

GPWV2 UL

Fan (Two provided, model Flatpack2 2000W 48V only)) Alternate

Sunon PMO1204PQB1-A

Rated: 17.6 CFM 12 Vdc, 0.39 A

GPWV2 UL

Fan (Two provided model Flatpack2 2000W 48V BF only)

Sanyo Denki 9GV0412J301 Rated: 24CFM 12 Vdc, 0.6 A

GPWV2 UL

Rectifier (DB100) Wontop elctronics GBJ25M Rated min. 1000 V, 25 A - - Rectifier (DB100) Alternate

Rectron RS2507M Rated min. 1000 V, 25 A - -

Inductor (L103) KASCHKE KG GMBH & CO.

060.166 Copper magnet wire wound on ferrite core. See enclosure 4-09 for details

- -

Inductor (L103) Alternate

Eltek 206380 Copper magnet wire wound on ferrite core. See enclosure 4-14 for details

- -

Page 18: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 15 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Diode (D103) Fairchild Semiconductor

ISL9R460PF2 Rated min. 600 V, 4 A - -

Diode (D104) ST Microelectronics STTH30R06CW Rated min. 600 V, 15 A - - Electrolytic Capacitors (C112-C114, C200)

Various Various Rated: 450 V, 220 uF, 105 C

- -

Switch Transistor (Q103) Infineon SPW35N60C3 Rated min. 600 V, 34 A - - Switch Transistor (Q105) Fairchild

Semiconductor FCP7N60 Rated min. 600 V, 7 A - -

Switch Transistor (Q200, Q201)

Infineon SPW47N60C3 Rated min. 600 V, 47 A - -

Capacitor (C105) Murata KX Line-to-Earth; 250 V, 1nF

FOWX2 UL

Capacitor (C105) Alternate

Murata KH Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Matsushita Type TS Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Vishay WYO Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Xiamen Faratronic MKP62 Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

TDK CS Line-to-Earth; 250 V, 1nF

FOKY2 UL

Inductor (L200) Eltek 204274 Open type construction Copper magnet winding wound on bobbin See enclosure for details.

- -

Page 19: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 16 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Transformer (T100, T101)

Eltek 204667 Open type construction. Core: Ferrite. Copper magnet winding wound on bobbin See enclosure for details.

- -

Electrolytic Capacitors (C211-C215, C217, C232, C236)

Various Various Rated: 63 V, 470 uF, 105 C

- -

Components in Flatpack2 24V only

- - - - -

Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Transformer (T200, T201)

Eltek 105169 Open type construction Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

OBJY2 -

Fan (Two provided) Sanyo Denki 9GV0412J301 Rated: 23.6CFM 12 Vdc, 0.6 A

GPWV2 UL

Fan (Two provided)

Sunon PMD1204PQB1-A Rated: 23.5 CFM

GPWV2 UL

Page 20: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 17 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Alternate 12 Vdc, 0.58 A. Blade: V-0 Rectifier (DB100) Wontop elctronics GBJ25M Rated min. 1000 V, 25 A - - Rectifier (DB100) Alternate

Rectron RS2507M Rated min. 1000 V, 25 A - -

Diode (D104) Infineon SDT12S60 Rated min. 600 V, 12 A - - Diode (D104) Alternate

ST Microelectronics STTH30R06CW Rated min. 600 V, 15 A - -

Electrolytic Capacitors (C110, C111, C113, C114, C200)

Various Various Rated: 450 V, 150 uF, 105 C

- -

Switch Transistor (Q103,Q106)

ST Microelectronics STW45NM60 Rated min. 600 V, 45 A - -

Switch Transistor (Q105) Fairchild Semiconductor

FCP7N60 Rated min. 600 V, 7 A - -

Switch Transistor (Q200, Q201)

Infineon SPW52N50C3 Rated min. 500 V, 52 A - -

Switch Transistor (Q200, Q201) Alternate

Infineon SPW47N60C3 Rated min. 600 V, 47 A - -

Inductor (L200) Eltek 204274 Copper magnet wire wound on Toroid core. See enclosure for details.

- -

Transformer (T100, T101)

Eltek 102620 Open type construction. Core: Ferrite. Copper magnet winding wound on bobbin See enclosure for details.

- -

Electrolytic Capacitors (C211-C215, C217, C232, C236, C237)

Various Various Rated: 35V, 1500uF, 105 C

- -

Page 21: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 18 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Page 22: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 19 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.6.2 TABLE: electrical data (in normal conditions) Pass

fuse # I rated (A) U (V) P (W) I (mA) I fuse (mA) condition/status Flatpack2 2000W 48V and Flatpack2 2000W 48V BF

F100/ F101

12.5 max 85, 50Hz 976 11450 11450 Normal load: 53.3V, 15.6A

supplementary information:

2.10.3 and 2.10.4

TABLE: clearance and creepage distance measurements Pass

clearance cl and creepage distance dcr at/of:

Up (V)

U r.m.s. (V) required cl (mm)

cl (mm) required dcr (mm)

dcr (mm)

Flatpack2 1800W 48V L-N before fuse 325 230 2.0 2.5 2.5 2.5 T201: Pin 4 - Pin 5 488 224 4.2 6 5.0 6 Pin 4 - Pin 6&7* 424 198 4.2 6 5.0 6 Pin 4 - Pin 8 368 172 4.2 6 5.0 6 Pin 2&3* - Pin 5 384 192 4.2 6 5.0 6 Pin 2&3* - Pin 6&7* 304 171 4.2 6 5.0 6 Pin 2&3* - Pin 8 256 155 4.2 6 5.0 6 Pin 1 - Pin 5 320 171 4.2 6 5.0 6 Pin 1 - Pin 6&7* 264 161 4.2 6 5.0 6 Pin 1 - Pin 8 296 157 4.2 6 5.0 6 Pin 4 - Earth 272 171 2.0 6 2.5 6 Pin 5 - Earth 400 177 2.0 6 2.5 6 T200: Pin 4 - Pin 5 408 181 4.2 6 5.0 6 Pin 4 - Pin 6&7* 264 158 4.2 6 5.0 6 Pin 4 - Pin 8 318 163 4.2 6 5.0 6 Pin 2&3* - Pin 5 344 164 4.2 6 5.0 6 Pin 2&3* - Pin 6&7* 336 163 4.2 6 5.0 6 Pin 2&3* - Pin 8 376 182 4.2 6 5.0 6 Pin 1 - Pin 5 352 170 4.2 6 5.0 6 Pin 1 - Pin 6&7* 376 190 4.2 6 5.0 6 Pin 1 - Pin 8 360 196 4.2 6 5.0 6 Pin 4 - Earth 384 171 2.0 3.4 2.5 3.4

Page 23: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 20 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin 5 - Earth 208 63 2.0 3.4 2.5 3.4 T202 Pin 1 - Pin 6 324 176 4.0 7.8 5.0 7.8 Pin 1 - Pin 7 348 195 4.0 7.8 5.0 7.8 Pin 1 - Pin 8 364 216 4.0 7.8 5.0 7.8 Pin 2 - Pin 6 340 194 4.0 7.8 5.0 7.8 Pin 2 - Pin 7 324 190 4.0 7.8 5.0 7.8 Pin 2 - Pin 8 304 178 4.0 7.8 5.0 7.8 Pin 3 - Pin 6 424 192 4.0 7.8 5.0 7.8 Pin 3 - Pin 7 404 187 4.0 7.8 5.0 7.8 Pin 3 - Pin 8 384 182 4.0 7.8 5.0 7.8 Pin 4 - Pin 6 448 197 4.0 7.8 5.0 7.8 Pin 4 - Pin 7 432 177 4.0 7.8 2.5 7.8 Pin 4 - Pin 8 408 181 4.0 7.8 2.5 7.8 Pin 5 - Pin 6 464 197 4.0 7.8 2.5 7.8 Pin 5 - Pin 7 440 201 4.0 7.8 2.5 7.8 Pin 5 - Pin 8 420 191 4.0 7.8 2.5 7.8 Q103 Pin 1 - Earth 424 193 2.1 3.4 2.5 3.4 Pin 2 - Earth 392 208.5 2.1 3.4 2.5 3.4 Pin 3 - Earth 428 195.1 2.1 3.4 2.5 3.4 D104 Pin 1 - Earth 396 199.9 2.2 3.4 2.5 3.4 Pin 2 - Earth 544 358.3 2.2 3.4 2.5 3.4 Q105 Pin 1 - Earth 400 190.3 2.1 3.4 2.5 3.4 Pin 2 - Earth 436 199 2.1 3.4 2.5 3.4 Pin 3 - Earth 400 186.9 2.1 3.4 2.5 3.4 Q200 Pin 1 - Earth 360 213.5 2.2 3.4 3.8 3.8 Pin 2 - Earth 544 377.8 2.2 3.4 3.8 3.8 Pin 3 - Earth 364 212.1 2.2 3.4 3.8 3.8 Q201 Pin 1 - Earth 444 205 2.1 3.4 2.5 3.4 Pin 2 - Earth 348 186.8 2.1 3.4 2.5 3.4 Pin 3 - Earth 428 204.5 2.1 3.4 2.5 3.4 U100 Pin 1 - Earth 408 144.8 2.1 5.5 2.5 5.5 Pin 2 - Earth 420 196.2 2.1 5.5 2.5 5.5 Pin 3 - Earth 428 183.6 2.1 5.5 2.5 5.5 ISO 200 Pin 4 - Pin 1 404 192 4.0 8.2 5.0 8.2 Pin 3 - Pin 2 416 172 4.0 8.2 5.0 8.2 ISO 201 Pin 1 - Pin 3 428 188 4.0 8.2 5.0 8.2

Page 24: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 21 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin 2 - Pin 4 444 208 4.0 8.2 5.0 8.2 ISO 202 Pin 4 - Pin 1 412 191 4.0 8.2 5.0 8.2 Pin 3 - Pin 2 416 178 4.0 8.2 5.0 8.2 Flatpack2 2000W 48V and Flatpack2 2000W 48V BF

L-N before fuse 354 250 2.0 2.5 2.5 2.5 T201 Pin4 - Pin5 442 210 4.2 6.4 ***) 5.0 6.4 ***) Pin4 - Pin6, 7 378 195 4.0 6.4 ***) 5.0 6.4 ***) Pin4 - Pin8 406 196 4.0 6.4 ***) 5.0 6.4 ***) Pin2,3* - Pin5 410 195 4.0 6.4 ***) 5.0 6.4 ***) Pin2,3* - Pin6, 7* 406 195 4.0 6.4 ***) 5.0 6.4 ***) Pin2,3* - Pin8 454 210 4.2 6.4 ***) 5.0 6.4 ***) Pin1 - Pin5 402 193 4.0 6.4 ***) 5.0 6.4 ***) Pin1 - Pin6, 7 442 205 4.2 6.4 ***) 5.0 6.4 ***) Pin1 - Pin8 494 230 4.4 6.4 ***) 5.0 6.4 ***) Pin4 – Earth 370 195 2.0 4.7 2.5 4.7 Pin5 – Earth 92 55 2.0 4.9 2.5 4.9 T200 Pin4 - Pin5 426 193 4.2 8.0 **) 5.0 8.0 **) Pin4 - Pin6, 7 442 205 4.2 8.0 **) 5.0 8.0 **) Pin4 - Pin8 494 230 4.4 8.0 **) 5.0 8.0 **) Pin2,3* - Pin5 442 205 4.2 8.0 **) 5.0 8.0 **) Pin2,3* - Pin6, 7* 490 229 4.2 8.0 **) 5.0 8.0 **) Pin2,3* - Pin8 545 264 4.4 8.0 **) 5.4 8.0 **) Pin1 - Pin5 460 221 4.2 8.0 **) 5.0 8.0 **) Pin1 - Pin6, 7 516 254 4.4 8.0 **) 5.2 8.0 **) Pin1 - Pin8 568 294 4.6 8.0 **) 6.4 8.0 **) Pin5 – Earth 71.6 53.3 2.0 4.9 2.5 4.9 T202 Pin1 - Pin6 430 248 4.2 6.4 **) 5.0 6.4 **) Pin1 - Pin7 453 262 4.2 6.4 **) 5.4 6.4 **) Pin1 - Pin8 470 277 4.2 6.4 **) 5.8 6.4 **) Pin2 - Pin6 267 168 4.0 6.4 **) 5.0 6.4 **) Pin2 - Pin7 245 167 4.0 6.4 **) 5.0 6.4 **) Pin2 - Pin8 256 168 4.0 6.4 **) 5.0 6.4 **) Pin3 - Pin6 356 165 4.0 8.2 5.0 8.2 Pin3 - Pin7 367 166 4.0 8.4 5.0 8.4 Pin3 - Pin8 386 167 4.0 10.2 5.0 10.2 Pin4 - Pin6 364 166 4.0 8.2 5.0 8.2 Pin4 - Pin7 348 165 4.0 8.4 5.0 8.4 Pin4 - Pin8 370 166 4.0 10.2 5.0 10.2 Pin5 - Pin6 370 163 4.0 7.5 5.0 7.5 Pin5 - Pin7 350 160 4.0 7.5 5.0 7.5 Pin5 - Pin8 341 159 4.0 7.5 5.0 7.5

Page 25: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 22 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Q103 Pin1 - Earth 342 162 2.0 3.2 2.5 3.2 Pin2 - Earth 486 243 2.1 3.2 2.5 3.2 Pin3 - Earth 338 165 2.0 3.2 2.5 3.2 D104 Pin1 - Earth 450 244 2.1 2.5 2.5 3.0 Pin2 - Earth 450 337 2.1 2.9 3.5 4.0 Q105 Pin1 - Earth 326 156 2.0 5.6 2.5 5.6 Pin2 - Earth 358 164 2.0 5.6 2.5 5.6 Pin3 - Earth 322 155 2.0 5.6 2.5 5.6 Q200 Pin1 - Earth 338 162 2.0 5.0 2.5 5.0 Pin2 - Earth 442 259 2.1 5.0 2.7 5.0 Pin3 - Earth 338 165 2.0 5.0 2.5 5.0 Q201 Pin1 - Earth 446 264 2.1 5.0 2.7 5.0 Pin2 - Earth 442 338 2.1 5.0 3.6 5.0 Pin3 - Earth 438 259 2.1 5.0 2.7 5.0 U100 Pin1 - Earth 334 161 2.0 5.5 2.5 5.5 Pin2 - Earth 334 161 2.0 5.5 2.5 5.5 Pin3 - Earth 322 154 2.0 5.5 2.5 5.5 ISO200 Pin1-Pin3 345 175 4.0 7.0 5.0 7.0 Pin1-Pin4 326 157 4.0 7.0 5.0 7.0 Pin2- Pin3 334 160 4.0 7.0 5.0 7.0 Pin2- Pin4 330 157 4.0 7.0 5.0 7.0 Pin3 - Earth 346 173.3 2.0 4.1 2.5 4.1 ISO201 Pin1-Pin3 340 166 4.0 7.0 5.0 7.0 Pin1-Pin4 358 176 4.0 7.0 5.0 7.0 Pin2- Pin3 345 166 4.0 7.0 5.0 7.0 Pin2- Pin4 360 176 4.0 7.0 5.0 7.0 ISO202 Pin1-Pin3 340 164 4.0 7.0 5.0 7.0 Pin1-Pin4 325 155 4.0 7.0 5.0 7.0 Pin2- Pin3 340 164 4.0 7.0 5.0 7.0 Pin2- Pin4 326 154 4.0 7.0 5.0 7.0 Flatpack2 24V L-N before fuse 354 250 2.0 2.5 2.5 2.5 L - Earth 354 250 2.0 2.5 2.5 2.5 T201 Pin4 - Pin5 592 226 4.6 6.7 5.0 6.7

Page 26: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 23 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin4 - Pin6, 7 556 219 4.4 6.7 5.0 6.7 Pin4 - Pin8 552 220 4.4 6.7 5.0 6.7 Pin2,3* - Pin5 560 218 4.4 6.7 5.0 6.7 Pin2,3* - Pin6, 7* 564 213 4.4 6.7 5.0 6.7 Pin2,3* - Pin8 584 218 4.6 6.7 5.0 6.7 Pin1 - Pin5 576 215 4.6 6.7 5.0 6.7 Pin1 - Pin6, 7 604 222 4.6 6.7 5.2 6.7 Pin1 - Pin8 620 229 4.6 6.7 5.0 6.7 Pin4 - Earth 516 190 2.2 4.3 2.5 4.3 Pin5 - Earth 76 35.6 2.0 5.6 2.5 5.6 T200 Pin4 - Pin5 576 214 4.6 7.4 5.0 7.4 Pin4 - Pin6, 7 604 222 4.6 7.4 5.0 7.4 Pin4 - Pin8 624 229 4.6 7.4 5.0 7.4 Pin2,3* - Pin5 620 230 4.6 7.4 5.0 7.4 Pin2,3* - Pin6, 7* 648 236 4.8 7.4 5.0 7.4 Pin2,3* - Pin8 665 252 4.8 7.4 5.2 7.4 Pin1 - Pin5 645 246 4.8 7.4 5.0 7.4 Pin1 - Pin6, 7 670 259 4.8 7.4 5.4 7.4 Pin1 - Pin8 690 270 4.8 7.4 5.6 7.4 Pin5 - Earth 64.0 35.6 2.0 3.0 2.5 3.0 T202 Pin1 - Pin6 568 252 4.6 7.3 5.2 7.3 Pin1 - Pin7 584 266 4.6 7.3 5.6 7.3 Pin1 - Pin8 596 280 4.6 7.3 6.0 7.3 Pin2 - Pin6 440 184 4.2 7.3 5.0 7.3 Pin2 - Pin7 436 185 4.2 7.3 5.0 7.3 Pin2 - Pin8 436 189 4.2 7.3 5.0 7.3 Pin3 - Pin6 180 103 4.0 7.3 5.0 7.3 Pin3 - Pin7 204 105 4.0 7.3 5.0 7.3 Pin3 - Pin8 224 109 4.0 7.3 5.0 7.3 Pin4 - Pin6 208 105 4.0 7.3 5.0 7.3 Pin4 - Pin7 188 103 4.0 7.3 5.0 7.3 Pin4 - Pin8 204 103 4.0 7.3 5.0 7.3 Pin5 - Pin6 236 109 4.0 7.3 5.0 7.3 Pin5 - Pin7 216 104 4.0 7.3 5.0 7.3 Pin5 - Pin8 192 101 4.0 7.3 5.0 7.3 Q103 Pin1 - Earth 254 149 2.0 2.7 2.5 2.7 Pin2 - Earth 558 238 2.2 4.4 3) 2.5 4.4 3) Pin3 - Earth 258 145 2.0 3.6 4) 2.5 3.6 4) D104 Pin1 - Earth 552 237 2.2 3.6 4) 2.5 3.6 4) Pin2 - Earth 564 333 2.2 3.6 4) 3.5 3.6 4) Q105 Pin1 - Earth 224 134 2.0 3.6 4) 2.5 3.6 4)

Page 27: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 24 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin2 - Earth 248 153 2.0 6.6 4) 2.5 6.6 4) Pin3 - Earth 224 134 2.0 3.6 4) 2.5 3.6 4) Q200 Pin1 - Earth 560 254 2.2 4.4 3) 2.6 4.4 Pin2 - Earth 564 332 2.2 3.6 4) 3.5 3.6 4) Pin3 - Earth 564 261 2.2 3.6 4) 2.7 3.6 4) Q201 Pin1 - Earth 256 148 2.0 3.6 4) 2.5 3.6 4) Pin2 - Earth 564 255 2.2 4.4 3) 2.6 4.4 Pin3 - Earth 256 146 2.0 3.6 4) 2.5 3.6 4) U100 Pin1 - Earth 208 131 2.0 4.1 4) 2.5 4.1 4) Pin2 - Earth 208 129 2.0 4.1 4) 2.5 4.1 4) Pin3 - Earth 196 124 2.0 4.1 4) 2.5 4.1 4) ISO200 Pin1-Pin3 - 2) - 2) 4.0 7.1 5.0 7.1 Pin1-Pin4 180 108 4.0 7.1 5.0 7.1 Pin2- Pin3 - 2) - 2) 4.0 7.1 5.0 7.1 Pin2- Pin4 180 108 4.0 7.1 5.0 7.1 Pin4 - Earth 204 126 2.0 4.1 1) 2.5 4.1 1) ISO201 Pin1-Pin3 204 123 4.0 7.1 5.0 7.1 Pin1-Pin4 216 135 4.0 7.1 5.0 7.1 Pin2- Pin3 204 123 4.0 7.1 5.0 7.1 Pin2- Pin4 220 144 4.0 7.1 5.0 7.1 ISO202 Pin1-Pin3 184 114 4.0 6.9 5.0 6.9 Pin1-Pin4 216 123 4.0 6.9 5.0 6.9 Pin2- Pin3 184 114 4.0 6.9 5.0 6.9 Pin2- Pin4 220 123 4.0 6.9 5.0 6.9 Comments *) Terminals directly connected to each other

**) Distance represents an internal measurement. For 2000W version: Measurement is performed with a refernce to earth and measured

***) Corrected measurement

1) Distance is measured from Pin3, since this distance is the shortest

2) EUT shutsdown when pin3 is connected to the oscilloscope. Measurement considered similar as to pin4

3) Measured on top of pcb. A plastic insulation is mounted between top cover and bottom cover and maintance the distance.

4) Measured on bottom side of PCB, until it reach the metal bottom chassis.

Page 28: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 25 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

the difference between primary and seondary side of the measured component. ISO203 is not mounted.

supplementary information:

2.10.5 TABLE: distance through insulation measurements Pass

distance through insulation di at/of: Up (V)

test voltage (V) required di (mm)

di (mm)

Flatpack2 1800W 48V - - - - Thin sheet material used inside T200, T201 230 4243 2 layers 2 layers Split bobbin T202 230 4243 0.4 0.58 Insulation material between pwb and metal enclosure

230 2121 - 0.188

Insulation material between pwb and metal enclosure

230 2121 - 0.43

Insulation material between switch transistors/diodes and heat sink

230 2121 - 0.15

Flatpack2 2000W 48V and Flatpack2 2000W 48V BF

- - - -

Thin sheet material used inside T200, T201 568 4250 2 layers 2 layers Split bobbin T202 470 4250 0.4 0.58 Insulation between PWB and bottom of chassis 486 2450 - Min. 0.12 Insulation between PWB and top chassis 486 2450 - Min. 0.18 Insulation between switch transistors/diodes and Heat sink

486 2450 - 0.15

Flatpack2 24V - - - - Thin sheet material used inside T200, T201 690 4250 2 layers 2 layers Split bobbin T202 596 4250 0.4 0.58 Insulation between PWB and bottom of chassis 564 2650 - Min. 0.12 Insulation between PWB and top chassis 564 2650 - Min. 0.18 Insulation between switch transistors/diodes and Heat sink

564 2650 - 0.15

All models - - - - Insulation Formex GK-5BK (used as alternative insulation between PWB and chassis)

564 2650 - 0.12

Insulation Formex GK-10 (used as alternative 564 2650 - 0.25

Page 29: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 26 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

insulation between PWB and chassis) Insulation Formex GK-17 (used as alternative insulation between PWB and chassis)

564 2650 - 0.43

Insulation Kunze, type KU 7-724/C45/CP (Shin-Etsu Chemical Co, type TC-45C) (used between Switch transistors/diodes and HeatSink) Alternate

564 2650 - 0.42

Insulation Richain, type GTR-B (Pioneer Conductor Rubber Industry, type PMP-P-400) (used between Switch transistors/diodes and HeatSink) Alternate

564 2650 - 0.42

Insulation Kunze, type KU-KG2.5 (E I DuPont, type Kapton, 100MT) (used between Switch transistors/diodes and HeatSink) Alternate

564 2650 - 0.025

supplementary information:

4.5 TABLE: temperature rise measurements Pass test voltage (V) ......................................... See

belowSee below

See below

See below

See below —

t1 (°C)........................................................ See below

See below

See below

See below

See below —

t2 (°C)........................................................ See below

See below

See below

See below

See below —

maximum temperature T of part/at: T (°C) allowed Tmax (°C)

Flatpack2 1800W 48V - - - - - - Flatpack2 1800W 48V Input

Condition : 205 V, 50 Hz,

Input Condition : 240 V, 60 Hz, 8.3 A, 1976

Input Condition : 240 V, 50 Hz, 8.3 A, 1970

- - -

Page 30: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 27 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

9.6A, 1960W, duration 2 hours ; Output Condition : 48.5 Vdc, 35.4 A

W, duration 55 min ; Output Condition : 48.0 Vdc, 35.4 A

W, duration 40 min ; Output Condition : 48 Vdc, 35.4 A

Ambient (t2) 27.6 27.9 27.5 - - -- 1. Connector CON100 (primary) (housing) 65.4 62.2 61.6 - - -- 2. X Capacitor C100 76.9 69.4 68.9 - - 105 3. Inductor L100 (windings) 95.0 81.9 81.4 - - 155 4. X Capacitor C101 65.0 59.8 59.2 - - 105 5. Inductor L101 73.3 65.6 65.0 - - 155 6. Fuse F100 66.1 60.4 59.8 - - -- 7. Not Connected -- -- -- - - -- 8. X Capacitor C102 51.9 49.9 49.3 - - 105 9. Inductor L102 79.0 71.0 70.4 - - 155 10. PWB near CON100 (Primary) didn’t work during this test

-- -- -- - - --

11. PWB near DB100 71.4 67.7 67.0 - - 130 12. Electrolytic Capacitor (top) C200 46.6 46.7 46.2 - - 105 13. Electrolytic Capacitor (top) C113 38.2 38.9 38.5 - - 105 14. Inductor L200 (core) 53.8 56.1 55.2 - - 155 15. Inductor L200 (windings) 69.6 72.9 71.7 - - 155 16. Transformer T202 (windings) 33.9 34.4 33.5 - - 90 17. Main Transformer T200 (windings) 87.1 91.9 90.6 - - 130 18. Main Transformer T200 (core) 68.8 71.8 70.6 - - 130 19. Main Transformer T201 (windings) 102.2 108.7 107.5 - - 130 20. Main Transformer T201 (core) 92.1 97.9 96.7 - - 130 21. PWB near D207 87.6 92.5 91.6 - - 130 22. Electrolytic capacitor C213 (top) 67.7 70.9 70.0 - - 105 23. Inductor L201 (windings) 72.8 76.8 75.8 - - 155 24. Inductor L202 (windings) 86.7 91.2 90.4 - - 155 25. PWB near output connector CON100 (SELV)

89.3 93.3 92.5 - - 130

26. Output connector CON100 (SELV) (housing)

85.2 89.1 88.2 - - --

27. Heat sink left 72.8 70 69.4 - - -- 28. Heat sink right 84.8 87.3 86.9 - - --

Page 31: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 28 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

29. Front bezel 27.5 28 26.8 - - 95 Flatpack2 1800W 48V Input

Condition: 205 V, 50 Hz, 9.7 A, 1965 W, duration 1 h 20 min; Output Condition: 48 Vdc, 36.1 A

Input Condition: 205 V, 50 Hz, 8.7 A, 1770 W, duration 55 min; Output Condition: 48 Vdc, 32.5 A

Input Condition: 205 V, 50 Hz, 6.7 A, 1350 W, duration 40 min; Output Condition: 47 Vdc, 25.4 A

- - -

Ambient (t2) 48.5 56.0 75.4 - - -- 1. Connector CON100 (primary) (housing) 70.6 75.5 90.2 - - -- 2. X Capacitor C100 83.3 86.4 98.5 - - 105 3. Inductor L100 (windings) 98.4 98.7 105.8 - - 155 4. X Capacitor C101 74.4 78.8 93.3 - - 105 5. Inductor L101 80.5 84.0 96.5 - - 155 6. Fuse F100 76.2 80.2 93.9 - - -- 7. Not Connected -- -- -- - - -- 8. X Capacitor C102 65.2 71.3 88.4 - - 105 9. Inductor L102 86.2 89.7 102.0 - - 155 10. PWB near CON100 (Primary) 71.0 76.0 90.9 - - -- 11. PWB near DB100 73.4 78.5 93.7 - - 130 12. Electrolytic Capacitor (top) C200 59.4 66.1 84.2 - - 105 13. Electrolytic Capacitor (top) C113 56.1 63.0 81.3 - - 105 14. Inductor L200 (core) 68.1 73.0 89.5 - - 155 15. Inductor L200 (windings) 83.7 86.6 99.3 - - 155 16. Transformer T202 (windings) 54.2 61.7 81.1 - - 90 17. Main Transformer T200 (windings) 97.0 99.0 108.1 - - 130 18. Main Transformer T200 (core) 79.8 84.2 97.4 - - 130 19. Main Transformer T201 (windings) 105.6 106.6 114.8 - - 130 20. Main Transformer T201 (core) 96.1 98.2 108.3 - - 130 21. PWB near D207 90.4 92.8 103.2 - - 130 22. Electrolytic capacitor C213 (top) 75.8 80.0 94.0 - - 105 23. Inductor L201 (windings) 79.2 83.0 96.1 - - 155 24. Inductor L202 (windings) 89.9 92.1 101.6 - - 155

Page 32: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 29 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

25. PWB near output connector C100 (SELV) 89.6 92.0 101.2 - - 130 26. Output connector C100 (SELV) (housing) 86.6 89.3 99.6 - - -- 27. Heat sink left 77.1 81.6 94.8 - - -- 28. Ambient temperature inside heating chamber

48.5 56.0 75.4 - - --

29. Front bezel 48.8 56.3 75.8 - - 95 Flatpack2 1800W 48V Input

Condition: 205 V, 50 Hz, 9.7 A, 1980 W, duration 1 h 10 min ; Output Condition: 48 Vdc, 36.3 A (short-circuit of NTC 200)

Input Condition: 205 V, 50 Hz, 9.7 A, 1960 W, duration 1 h 5 min; Output Condition: 48 Vdc, 36 A (short-circuit of NTC 100 on primary side – main board)

Input Condition: 205 V, 50 Hz, 9.6 A, 1950 W, duration 50 min; Output Condition: 48 Vdc, 36 A (short-circuit of NTC 100 on primary side – main board)

Input Condition: 205 V, 50 Hz, 9.3 A, 1890 W, duration 1 h 10 min ; Output Condition: 48 Vdc, 35.1 A (short-circuit of NTC 100 on the small card)

Input Condition: 210 V, 50 Hz, 0.7 A, 119 W, duration 1 h 25 min ; Output Condition:0.2 Vdc, 29.8 A (short-circuit of the output)

-

Ambient (t2) 48.1 49.2 75.7 47.9 75.0 -- 1. Connector CON100 (primary) (housing) 69.5 71.3 89.8 77.9 80.6 -- 2. X Capacitor C100 82.9 84.9 97.2 96.3 81.4 -- 3. Inductor L100 (windings) 99.2 102.2 105.7 115.4 81.5 -- 4. X Capacitor C101 74.4 77.0 92.9 87.4 81.4 -- 5. Inductor L101 79.9 82.6 96.4 93.8 81.4 -- 6. Fuse F100 75.5 77.8 93.6 86.6 81.4 -- 7. Not Connected -- -- -- -- -- -- 8. X Capacitor C102 64.6 66.0 87.8 72.8 81.5 -- 9. Inductor L102 85.3 88.0 102.0 101.8 82.6 -- 10. PWB near CON100 (Primary) 69.5 71.1 90.2 79.8 83.9 -- 11. PWB near DB100 71.8 61.4 97.4 65.6 81.8 -- 12. Electrolytic Capacitor (top) C200 59.6 60.2 83.2 65.7 80.6 -- 13. Electrolytic Capacitor (top) C113 55.4 57.0 80.9 59.7 79.8 -- 14. Inductor L200 (core) 67.3 69.0 88.8 74.5 104.8 --

Page 33: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 30 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

15. Inductor L200 (windings) 82.7 85.2 98.7 90.5 117.4 -- 16. Transformer T202 (windings) 53.6 55.0 80.5 55.0 79.9 150 17. Main Transformer T200 (windings) 97.5 99.6 108.2 109.1 105.2 190 18. Main Transformer T200 (core) 79.3 80.2 96.6 89.3 93.0 190 19. Main Transformer T201 (windings) 105.5 109.2 114.7 125.4 109.4 190 20. Main Transformer T201 (core) 94.6 98.3 107.8 114.5 103.8 190 21. PWB near D207 90.8 92.9 103.8 104.4 105.6 -- 22. Electrolytic capacitor C213 (top) 74.5 78.3 94.4 86.5 94.8 -- 23. Inductor L201 (windings) 79.1 80.9 96.3 91.6 97.2 -- 24. Inductor L202 (windings) 88.4 90.4 101.5 102.6 103.2 -- 25. PWB near output connector C100 (SELV) 89.0 91.7 102.0 100.0 103.8 -- 26. Output connector C100 (SELV) (housing) 85.8 88.1 99.9 96.4 101.4 -- 27. Heat sink left 79.6 83.6 100.5 87.2 82.0 -- 28. Ambient temperature inside heating chamber

48.1 49.2 75.7 47.9 75.0 --

29. Front bezel 48.6 49.6 75.8 48.2 75.1 -- Flatpack2 1800W 48V Input

Condition: 205 V, 50 Hz, 7.8 A, 1650 W, duration 1 h 40 min ; Output Condition: 48 Vdc, 31.5 A (blocked ventilation)

- - - - -

Ambient (t2) 45.1 - - - - -- 1. Connector CON100 (primary) (housing) 65.4 - - - - -- 2. X Capacitor C100 70.5 - - - - -- 3. Inductor L100 (windings) 88.4 - - - - -- 4. X Capacitor C101 85.9 - - - - -- 5. Inductor L101 98.6 - - - - -- 6. Fuse F100 89.7 - - - - --

Page 34: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 31 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

7. Not Connected -- - - - - -- 8. X Capacitor C102 96.1 - - - - -- 9. Inductor L102 122.7 - - - - -- 10. PWB near CON100 (Primary) 66.0 - - - - -- 11. PWB near DB100 83.4 - - - - -- 12. Electrolytic Capacitor (top) C200 91.7 - - - - -- 13. Electrolytic Capacitor (top) C113 94.0 - - - - -- 14. Inductor L200 (core) 127.9 - - - - -- 15. Inductor L200 (windings) 139.2 - - - - -- 16. Transformer T202 (windings) 94.0 - - - - 150 17. Main Transformer T200 (windings) 131.0 - - - - 190 18. Main Transformer T200 (core) 110.1 - - - - 190 19. Main Transformer T201 (windings) 139.5 - - - - 190 20. Main Transformer T201 (core) 128.2 - - - - 190 21. PWB near D207 121.7 - - - - -- 22. Electrolytic capacitor C213 (top) 101.6 - - - - -- 23. Inductor L201 (windings) 112.1 - - - - -- 24. Inductor L202 (windings) 94.9 - - - - -- 25. PWB near output connector C100 (SELV) 83.7 - - - - -- 26. Output connector C100 (SELV) (housing) 79.2 - - - - -- 27. Heat sink left 80.9 - - - - -- 28. Ambient temperature inside heating chamber

45.1 - - - - --

29. Front bezel 67.9 - - - - -- Flatpack2 1800W 48V Transf

ormer T200 and T201 version 5: Input Condition: 264 Vac, 50 Hz, 7.4 A, 1945 W, Output Condition: 48 Vdc, 36.1

Transformer T200 and T201 version 5: Input Condition: 264 V, 50 Hz, 7.4 A, 1935 W, Output Condition: 52.7 Vdc, 33.1 A

Transformer T200 and T201 version 5: Input Condition: 87.2 Vac, 50 Hz, 8.4 A, 740 W, Output Condition: 47.2 Vdc, 13.2 A

Transformer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 10.5 A, 1965 W, Output Condition: 48 Vdc, 36.6 A

Transformer T200 and T201 version 5: Input Condition:264.7 Vac, 50 Hz, 6.9 A, 1807 W, Output Condition:47.7 Vdc, 33.9 A

Page 35: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 32 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

A Ambient (t2) 24.2 23.6 25.1 24.2 24.2 -- Humidity (2), RH (%) 21.9 27.4 25.5 24.2 16.3 -- 1. Ambient inside chamber -- -- -- 52.3 49.9 -- 3. Transformer T200 (bobbin) 52.9 53.5 43.3 71.3 69.1 130 4. Transformer T200 (windings) 70.4 70.5 52.3 86.1 83.7 130 5. Transformer T201 (bobbin) 67.9 68.0 52.0 80.9 78.6 130 6. Transformer T201 (windings) 72.0 70.7 51.4 84.4 82.0 130 7. PWB near T201 82.4 78.4 53.6 82.4 79.5 130 Flatpack2 1800W 48V Transf

ormer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 10 A, 1871 W, Output Condition: 47.7 Vdc, 35.1 A

Transformer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 9.0 A, 1685 W, Output Condition: 48.3 Vdc, 31.1 A

Transformer T200 and T201 version 5: Input Condition: 187.3 Vac, 50 Hz, 7.6 A, 1411 W, Output Condition: 48.1 Vdc, 26.4 A

Transformer T200 and T201 version 5: Input Condition: 91 Vac, 50 Hz, 6.4 A, 580 W, Output Condition: 48.5 Vdc, 10.4 A

Transformer T200 and T201 version 5: Input Condition: 264 Vac, 50 Hz, 5.5 A, 1452 W, Output Condition:48 Vdc, 27.5 A

-

Ambient (t2) 24.8 24.2 24.6 24.7 24.8 -- Humidity (2), RH (%) 16.8 18.7 17.5 17.1 16.8 -- 1. Ambient (Inside chamber) 52.0 59.7 74.8 74.4 74.4 -- 3. Transformer T200 (bobbin) 70.7 75.4 87.0 78.6 87.0 130 4. Transformer T200 (windings) 85.1 87.4 96.1 82.6 96.3 130 5. Transformer T201 (bobbin) 80.2 84.0 94.8 81.7 95.0 130 6. Transformer T201 (windings) 84.2 88.0 96.0 81.1 96.1 130 7. PWB near T201 81.4 84.2 93.7 78.6 90.7 130 Flatpack2 1800W 48V Transf

ormer T200 and T201 versio

Transformer T200 and T201 version

Transformer T200 and T201 version

Transformer T200 and T201 version

Transformer T200 and T201 version 5: Input Condition:

-

Page 36: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 33 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

n 5: Input Condition: 187 Vac, 50 Hz, 10 A, 1871 W, Output Condition: 47.7 Vdc, 35.1 A

5: Input Condition: 187 Vac, 50 Hz, 9.0 A, 1685 W, Output Condition: 48.3 Vdc, 31.1 A

5: Input Condition: 187.3 Vac, 50 Hz, 7.6 A, 1411 W, Output Condition: 48.1 Vdc, 26.4 A

5: Input Condition: 91 Vac, 50 Hz, 6.4 A, 580 W, Output Condition: 48.5 Vdc, 10.4 A

264 Vac, 50 Hz, 5.5 A, 1452 W, Output Condition:48 Vdc, 27.5 A

Ambient (t2) 24.8 24.2 24.6 24.7 24.8 - Humidity (2), RH (%) 16.8 18.7 17.5 17.1 16.8 - 1. Ambient (Inside chamber) 52.0 59.7 74.8 74.4 74.4 - 3. Transformer T200 (bobbin) 70.7 75.4 87.0 78.6 87.0 130 4. Transformer T200 (windings) 85.1 87.4 96.1 82.6 96.3 130 5. Transformer T201 (bobbin) 80.2 84.0 94.8 81.7 95.0 130 6. Transformer T201 (windings) 84.2 88.0 96.0 81.1 96.1 130 7. PWB near T201 81.4 84.2 93.7 78.6 90.7 130 Flatpack2 1800W 48V Transf

ormer T200 and T201 version 5: Input Condition: 264 Vac, 50 Hz, 7.4 A, 1931 W, Output Condition:

Transformer T200 and T201 version 5: Input Condition: 86.1 V, 50 Hz, 8.2 A, 706 W, Output Condition: 47.6 Vdc, 12.1 A

- - - -

Page 37: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 34 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

47.9 Vdc, 36.1 A

Ambient (t2) 25.3 25.2 - - - - Humidity (2), RH (%) 15.9 19.2 - - - - 1. Ambient (Inside chamber) 49.4 46.4 - - - - 3. Transformer T200 (bobbin) 68.3 52.2 - - - 130 4. Transformer T200 (windings) 81.9 56.8 - - - 130 5. Transformer T201 (bobbin) 78.8 55.5 - - - 130 6. Transformer T201 (windings) 82.3 55.1 - - - 130 7. PWB near T201 74.4 52.6 - - - 130 Flatpack2 1800W 48V Transf

ormer T200 and T201 version 5: Input Condition: 187.7 V, 50 Hz, 3.3 A, 610 W, Output Condition: 11.5 Vdc, 37.5 A

Transformer T200 and T201 version 5: Input Condition: 189.6 V, 50 Hz, 0.9 A, 192 W, Output Condition (S/C): 0.2 Vdc, 36.4 A

Transformer T200 and T201 version 5: Input Condition: 187 V, 50 Hz, 10.5 A, 1050 W, Output Condition: 47.9 Vdc, 35.8 A (NTC100 SC on the small card)

Transformer T200 and T201 version 5: Input Condition: 187.9 V, 50 Hz, 10.5 A, 1966 W, Output Condition: 48.6 Vdc, 36.4 A (short-circuit of NTC 200)

- -

Ambient (t2) 24.3 24.5 25.3 - - Humidity (2), RH (%) 20.4 20.2 20.6 - - 1. Ambient (Inside chamber) 48.8 47.3 44.3 23.8 - - 3. Transformer T200 (bobbin) 67.0 64.4 75.0 68.9 - 190 4. Transformer T200 (windings) 80.5 77.4 86.9 76.5 - 190 5. Transformer T201 (bobbin) 77.6 74.6 85.6 76.3 - 190 6. Transformer T201 (windings) 84.4 81.7 88.8 92.2 - 190 7. PWB near T201 75.6 73.3 57.9 93.0 - - Flatpack2 2000W 48V -

Page 38: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 35 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Flatpack2 2000W 48V Input Condition : 85 V, 50 Hz, 11.4A, 966W, duration 7 h, 48min ; Output Condition : 52.3 Vdc, 16.2 A

Input Condition : 100 V, 50 Hz, 11.5A, 1118W, duration 7 h, 48min ; Output Condition : 51.9 Vdc, 18.8 A

Input Condition : 185 V, 50 Hz, 11.7A, 2183W, duration 2 h, 28min ; Output Condition : 52.7 Vdc, 37.3 A

Input Condition : 230 V, 50 Hz, 9.4A, 2155W, duration 1 h, 4min ; Output Condition : 52.7 Vdc, 37.3 A

Input Condition : 250 V, 50 Hz, 8.7A, 2178W, duration 20min ; Output Condition : 53.1 Vdc, 37.7 A

-

Con100 housing 62.9 63.9 71.4 66.8 65.5 - C100 67.8 68.5 73.8 66.8 65.0 105 L100 winding 78.0 78.9 84.1 72.4 69.4 155 C101 69.4 70.0 73.7 65.7 63.7 105 L101 80.5 81.4 86.0 73.0 69.8 155 F100 71.4 72.1 75.6 66.3 64.0 - T202 core 56.5 56.6 56.8 56.6 56.6 90 C102 60.9 61.3 63.6 59.3 58.2 105 L102 82.7 84.5 92.5 77.3 73.4 155 PWB near CON100 68.8 69.4 73.7 67.4 65.8 130 PWB near DB100 75.5 76.3 80.8 73.2 71.1 130 C200 top 56.9 57.3 59.7 57.1 56.5 105 C113 top 50.5 50.8 52.5 51.6 51.3 105 L200 core 53.9 55.4 67.4 67.0 66.9 155 L200 coil 60.3 63.6 90.0 89.6 89.6 155 T202 coil 52.8 52.8 52.6 52.4 52.3 90 T200 coil 59.4 61.7 83.7 83.5 83.7 130 T200 core 61.7 63.5 79.4 78.8 78.8 130 T201 coil 63.6 66.2 91.2 90.6 90.6 130 T201 core 62.1 64.1 83.7 83.0 82.9 130 PWB near D207 62.4 65.5 91.7 91.1 91.1 130 C213 top 56.6 58.0 70.0 69.1 68.9 105 T100 core/coil 54.3 54.7 56.6 56.5 56.4 90 L202 winding 58.6 60.8 82.0 81.2 81.0 155 PWB near L202 60.5 62.5 81.0 80.1 79.9 130

Page 39: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 36 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

CON100 housing SELV 58.5 60.9 82.4 81.3 81.2 - Heat sink left 63.3 66.1 85.0 84.0 83.9 - Heat sink right 71.0 72.0 77.9 72.6 71.2 - Front bezel 46.2 46.3 45.5 45.5 45.5 95 T101 core/coil 51.0 51.3 52.8 52.8 52.7 90 Metal chassis top 58.9 59.4 64.2 61.8 61.0 - Ambient 45.0 44.8 43.2 43.9 44.1 - Flatpack2 2000W 48V Input

Condition : 275 V. 50 Hz. 7.8A. 2171W. duration 16 h. 39min ; Output Condition : 53.1 Vdc. 37.6 A

Input Condition : 185 V. 50 Hz. 7.5A. 1389W. duration 53min ; Output Condition : 43.8 Vdc. 28.7 A

- - - -

Con100 housing 64.5 91.8 - - - - C100 63.3 91.8 - - - 105 L100 winding 66.5 95.7 - - - 155 C101 61.8 91.3 - - - 105 L101 66.6 96.5 - - - 155 F100 61.9 91.8 - - - - T202 core 56.5 83.0 - - - 90 C102 57.1 86.8 - - - 105 L102 69.4 99.4 - - - 155 PWB near CON100 64.0 92.3 - - - 130 PWB near DB100 68.9 96.7 - - - 130 C200 top 55.9 85.2 - - - 105 C113 top 51.1 80.7 - - - 105 L200 core 67.2 90.7 - - - 155 L200 coil 89.9 105.7 - - - 155 T202 coil 52.3 80.1 - - - 90 T200 coil 83.8 101.6 - - - 130 T200 core 78.8 99.3 - - - 130

Page 40: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 37 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

T201 coil 90.6 106.4 - - - 130 T201 core 83.1 101.7 - - - 130 PWB near D207 91.0 108.1 - - - 130 C213 top 68.9 93.3 - - - 105 T100 core/coil 56.5 85.4 - - - 90 L202 winding 80.9 100.6 - - - 155 PWB near L202 79.7 100.2 - - - 130 CON100 housing SELV 80.8 100.5 - - - - Heat sink left 83.7 103.9 - - - - Heat sink right 69.7 95.9 - - - - Front bezel 45.4 76.0 - - - 95 T101 core/coil 53.0 82.1 - - - 90 Metal chassis top 60.5 88.0 - - - - Ambient 43.6 74.8 - - - - Flatpack2 2000W 48V Input

Condition : 186 V. 50 Hz. 0.8A. 128W. duration 53min ; Output Condition : S-c. 0.6Vdc. 29.7 A

Input Condition : 190 V. 50 Hz. 8.5A. 1606W. duration 1 h. 45min ; Output Condition : Blocked ventilation.47.0 Vdc. 30.8 A

Input Condition : 190 V. 50 Hz. 8.5A. 1606W. duration 13min ; Output Condition : Blocked ventilation.41.5 Vdc. 30.8 A

Input Condition : 191 V. 50 Hz. 6.9A. 1309W. duration 1h. 43min ; Output Condition : NTC200 dis.. 40.8Vdc. 28.9 A

- -

Con100 housing 87.2 87.5 89.2 91.2 - - C100 84.2 90.5 86.3 90.6 - - L100 winding 83.6 115.8 104.4 93.8 - - C101 83.1 115.0 94.5 90.1 - - L101 83.6 130.5 108.2 94.4 - - F100 83.2 121.0 108.4 90.3 - - T202 core 85.6 81.5 80.2 83.2 - - C102 83.1 110.7 91.8 86.3 - - L102 86.0 142.3 116.2 97.1 - - PWB near CON100 82.9 92.0 91.8 91.1 - - PWB near DB100 83.6 108.0 102.9 95.2 - -

Page 41: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 38 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

C200 top 82.9 93.2 81.2 85.1 - - C113 top 80.4 79.6 73.7 81.5 - - L200 core 109.9 101.5 90.8 92.2 - - L200 coil 127.6 112.3 106.9 107.3 - - T202 coil 81.1 77.7 78.1 80.4 - 150 T200 coil 101.6 124.6 122.4 97.5 - 190 T200 core 93.0 132.0 113.6 97.1 - 190 T201 coil 103.7 140.7 122.4 107.7 - 190 T201 core 98.2 131.7 115.8 101.6 - 190 PWB near D207 108.6 119.8 118.5 107.8 - - C213 top 92.4 107.8 93.3 94.0 - - T100 core/coil 91.8 85.3 89.9 86.1 - - L202 winding 100.1 116.4 111.2 101.0 - - PWB near L202 98.0 116.6 109.6 100.1 - - CON100 housing SELV 99.9 93.0 101.6 100.3 - - Heat sink left 101.6 102.7 115.1 103.3 - - Heat sink right 84.2 97.4 102.0 94.8 - - Front bezel 75.9 57.2 74.3 76.5 - - T101 core/coil 85.8 80.6 87.3 82.6 - - Metal chassis top 84.3 82.7 91.3 83.3 - - Ambient 75.1 44.9 72.3 75.4 - - Flatpack2 2000W 48V Input

Condition : 190 V. 50 Hz. 10.5A. 1990W. duration 1h. 43min ; Output Condition : NTC100 dis. on main PCB. 50.1Vdc. 35.2A

Input Condition : 187 V. 50 Hz. 7.1A. 1318W. duration 1h. 41min ; Output Condition : NTC100 dis. on internal PCB. 40.8Vdc. 29.1A

- - - -

Page 42: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 39 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Con100 housing 100.7 91.8 - - - - C100 101.3 91.2 - - - - L100 winding 110.3 94.5 - - - - C101 104.1 90.7 - - - - L101 112.1 95.1 - - - - F100 105.4 90.5 - - - - T202 core 86.3 83.3 - - - - C102 97.7 86.9 - - - - L102 118.6 97.8 - - - - PWB near CON100 101.2 91.6 - - - - PWB near DB100 105.8 95.6 - - - - C200 top 92.6 84.9 - - - - C113 top 85.6 81.4 - - - - L200 core 100.4 92.9 - - - - L200 coil 113.6 108.6 - - - - T202 coil 83.1 80.6 - - - 150 T200 coil 114.2 98.3 - - - 190 T200 core 114.8 99.8 - - - 190 T201 coil 125.3 107.7 - - - 190 T201 core 116.4 103.0 - - - 190 PWB near D207 118.3 111.8 - - - - C213 top 103.2 94.6 - - - - T100 core/coil 89.2 86.2 - - - - L202 winding 111.8 102.3 - - - - PWB near L202 110.7 101.5 - - - - CON100 housing SELV 108.0 102.0 - - - - Heat sink left 116.6 112.7 - - - - Heat sink right 103.0 94.8 - - - - Front bezel 76.9 76.6 - - - - T101 core/coil 85.9 82.9 - - - - Metal chassis top 90.5 82.3 - - - - Ambient 75.7 75.5 - - - - Flatpack2 24V - - - - - - Flatpack2 24V Input

Condition : 85 V, 50 Hz, 9.4A, duration 1 h, 29min ; Output

Input Condition : 100 V, 50 Hz, 10.4A, duration 2 h, 10min ; Output Condition : 24.2Vdc, 36.9 A

Input Condition : 176 V, 50 Hz, 13.4A, duration 3 h, 44min ; Output Condition : 24.2 Vdc, 83.3 A

Input Condition : 230 V, 50 Hz, 10.0A, duration 14 h, 17min ; Output Condition : 24.2 Vdc, 82.4 A

Input Condition : 250 V, 50 Hz, 9.1A, duration 1h 14min ;Output Condition : 24.2 Vdc, 82.4 A

Page 43: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 40 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Condition : 24.2 Vdc, 27.6 A

Con100 housing 58.2 59.9 74.1 69.7 67.3 - C100 62.5 64.9 78.6 70.4 67.0 105 L100 winding 67.1 70.5 87.3 75.5 71.4 155 C101 63.2 65.6 79.2 70.6 67.0 105 L101 66.2 69.5 85.8 73.9 69.5 155 F100 62.7 65.3 78.8 70.1 66.3 - C102 59.7 61.0 70.8 66.0 63.2 105 L102 67.6 71.6 91.3 76.5 71.5 155 PWB near CON100 58.0 59.7 72.7 67.9 65.5 130 PWB near DB100 71.3 74.4 90.9 81.0 76.8 130 C200 top 54.5 55.2 63.2 61.8 60.0 105 C113 top 53.2 53.5 58.9 58.5 56.8 105 L200 core 53.6 54.3 61.6 62.0 60.3 155 L200 coil 52.4 53.5 58.0 58.2 56.9 155 T202 coil 53.4 54.2 56.4 55.4 54.0 90 T200 coil 60.3 63.0 97.1 95.5 93.0 130 T200 core 63.6 66.1 98.6 98.1 96.6 130 T201 coil 65.0 69.5 118.4 118.1 116.4 130 T201 core 59.4 61.9 92.2 90.9 89.1 130 PWB near D207 59.9 63.5 100.8 100.2 98.4 130 C213 top 56.4 58.3 81.2 80.4 78.7 105 Ambient1 48.3 50.8 50.6 50.1 49.5 - L202 winding 59.3 63.1 104.5 104.0 102.2 155 PWB near CON100 58.0 60.8 92.9 92.5 90.8 130 CON100 housing SELV 57.6 60.3 91.0 90.9 89.5 - Heat sink near D211 60.1 63.6 90.3 88.6 86.9 - Heat sink near D104 62.9 65.0 79.6 74.1 71.3 - Front bezel 49.8 50.3 51.3 51.7 50.5 95 Ambient2 48.0 50.3 49.7 50.2 49.5 - Flatpack2 24V Input

Condition : 278 V. 50 Hz. 8.3A. duration 1 h. 31min ;

Input Condition : 85 V, 50 Hz, 5.9A, duration 1 h, 28min ; Output Condition : 22.2 Vdc,

Input Condition : 176 V, 50 Hz, 6.5A, duration 1 h, 58min ; Output Condition : 17.5

Input Condition : 250 V, 50 Hz, 4.5A, duration 17h 31min ; Output Condition : 17.5

Input Condition : 275 V. 50 Hz. 4.5A. duration 1 h. 59min ; Output Condition : 19.0 Vdc. 56.9 A

-

Page 44: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 41 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Output Condition : 24.2 Vdc. 82.7 A

18.9 A Vdc, 55.7 A

Vdc, 55.7 A

Con100 housing 66.6 83.4 89.8 88.0 87.9 - C100 65.4 84.1 88.3 85.9 84.8 105 L100 winding 69.0 85.6 89.9 86.5 85.5 155 C101 65.3 84.1 88.0 85.6 84.7 105 L101 67.2 85.2 89.1 85.9 85.0 155 F100 64.4 84.4 87.9 85.6 84.8 - T202 core 82.0 85.3 85.4 85.5 90 C102 61.9 81.9 85.4 84.3 83.7 105 L102 68.6 86.1 91.2 87.6 86.8 155 PWB near CON100 64.5 82.7 88.9 87.7 87.3 130 PWB near DB100 74.3 87.7 92.8 89.8 89.3 130 C200 top 59.5 80.5 84.7 84.4 84.5 105 C113 top 56.4 78.7 81.3 81.5 81.6 105 L200 core 60.0 79.8 92.6 92.9 92.3 155 L200 coil 56.3 80.4 97.6 97.9 97.3 155 T202 coil 53.5 79.4 81.5 81.9 81.9 90 T200 coil 93.0 85.2 102.8 103.2 103.0 130 T200 core 96.4 85.1 96.9 97.3 97.4 130 T201 coil 116.2 86.9 110.9 111.2 110.9 130 T201 core 88.8 87.5 105.2 105.4 105.5 130 PWB near D207 98.2 84.4 108.8 109.0 108.7 130 C213 top 78.5 81.7 93.5 93.8 93.7 105 Ambient1 49.0 75.3 75.2 75.5 75.8 - L202 winding 102.1 84.5 112.4 112.5 112.4 155 PWB near CON100 90.6 83.1 102.2 102.1 102.1 130 CON100 housing SELV 89.4 82.2 97.3 96.9 97.1 - Heat sink near D211 86.5 85.9 108.2 108.2 108.4 - Heat sink near D104 69.7 87.7 94.3 92.1 91.9 - Front bezel 50.0 75.6 76.0 76.4 76.5 95 Ambient2 49.0 75.6 76.0 76.0 76.3 - Flatpack2 24V Input

Condition : 176 V. 50 Hz. 0.5A. duration 7h

Input Condition : 177 V. 50 Hz. 6.5A. duration 19min ; Output

- - - -

Page 45: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 42 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

14min ; Output Condition : S-c. 0.4Vdc. 71.1 A

Condition : NTC100 on main board removed. Unit damaged, start at 25.0Vdc. 79.6 A Max. temp. measured

Con100 housing 87.9 85.0 - - - - C100 84.1 92.9 - - - - L100 winding 83.8 95.5 - - - - C101 83.4 90.8 - - - - L101 83.1 97.4 - - - - F100 83.0 104.7 - - - - T202 core 84.9 - - - - 150 C102 83.1 90.1 - - - - L102 84.9 103.9 - - - - PWB near CON100 87.7 87.8 - - - - PWB near DB100 85.4 105.5 - - - - C200 top 84.8 84.3 - - - - C113 top 82.0 81.6 - - - - L200 core 98.6 88.9 - - - - L200 coil 104.2 93.2 - - - - T202 coil 81.9 83.1 - - - 150 T200 coil 106.5 112.6 - - - 190 T200 core 98.7 95.0 - - - 190 T201 coil 116.3 120.2 - - - 190 T201 core 108.2 95.0 - - - 190 PWB near D207 115.3 108.7 - - - - C213 top 96.2 89.9 - - - - Ambient1 76.5 73.4 - - - - L202 winding 127.1 106.8 - - - - PWB near CON100 111.0 102.3 - - - - CON100 housing SELV 103.4 104.7 - - - - Heat sink near D211 114.1 106.6 - - - - Heat sink near D104 86.5 100.5 - - - - Front bezel 76.8 74.1 - - - - Ambient2 76.2 73.5 - - - - Flatpack2 24V Input Input Input Input - -

Page 46: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 43 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Condition : 180 V. 50 Hz. 5.6A. duration 36min ; Output Condition : Blocked ventilation. Unit shut down, start at 26.5 Vdc. 75.1 A

Condition : 177 V. 50 Hz. 8.4A. duration 2h. 1min ; Output Condition : NTC200 dis. on main PCB. 20.3Vdc. 62.6A

Condition : 176 V. 50 Hz. 12.5A. duration 1h. 58min ; Output Condition : NTC100 dis. on internal PCB. 25.0Vdc. 77.6A

Condition : 250 V. 50 Hz. 10.3A. duration 1h. 39min ; Output Condition : Transformer overload. Unit damaged 25.2Vdc. 77.7A. Additional load increased from 0 - 46.8A

T202 core 90.3 83.8 84.2 - - 150 L200 coil 99.7 95.9 98.4 - - - T200 coil 122.2 109.2 112.6 118.1 - 190 T200 core 111.8 98.2 101.4 110.6 - 190 T201 coil 131.0 120.5 124.5 145.0 - 190 T201 core 114.3 105.1 108.5 122.9 - 190 L202 winding 111.5 99.9 103.2 - - - Ambient 75.1 75.0 75.0 24.9 - - Flatpack2 2000W 48V BF Test:

185Vac 50C Input: 184.2Vac, 12.2A, 50Hz Output: 53.06

Test 230Vac 50C Input: 231.5Vac, 9.6A, 50Hz Output: 53.06Vdc, 37.7A

Test: 275Vac 50C Input: 277.4Vac, 8.0A, 50Hz Output: 53.06Vdc, 37.7A

Test: 85Vac 50C Input: 86.5Vac, 11.7A, 50Hz Output: 53.1Vdc, 16.1A

Test: 185Vac 65C Input: 186.5Vac, 9.5A, 50Hz Output: 46.7Vdc, 33.3A

-

Page 47: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 44 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Vdc, 37.7A

Ambient 50.3 50.0 49.9 49.8 64.9 - Con100 housing 53.5 52.9 52.6 51.2 67.5 - C100 52.2 51.7 51.3 51.2 66.5 105 L100 winding 65.8 59.8 56.8 63.5 75.0 155 C101 56.2 54.1 53.1 54.9 69.2 105 L101 74.3 65.0 60.5 70.7 80.3 155 F100 67.4 60.8 57.6 64.7 75.7 - T202 core 80.1 75.6 73.3 74.1 87.5 90 C102 61.1 57.3 55.4 59.1 72.4 105 L102 70.9 62.7 58.6 66.3 77.9 155 PWB near CON100 55.9 54.9 54.3 52.8 69.2 130 PWB near DB100 72.7 66.8 63.6 69.9 81.5 130 C200 top 64.0 60.0 57.9 60.6 74.5 105 C113 top 63.6 61.4 60.2 58.1 75.2 105 L200 core 76.5 72.7 70.8 64.8 85.4 155 L200 coil 79.4 75.0 72.6 66.2 88.1 155 T202 coil 72.9 69.1 67.1 66.6 82.3 90 T200 coil 90.0 89.4 88.9 63.5 97.1 130 T200 core 84.5 83.7 83.0 65.8 92.4 130 T201 coil 78.6 78.3 77.8 59.2 88.1 130 C213 top 59.3 58.9 58.7 52.0 72.2 105 T100 core_coil 73.9 72.7 71.9 61.6 84.8 90 L202 winding 59.8 59.4 59.2 51.3 72.4 155 PWB near L202 63.0 62.7 62.5 53.0 75.2 130 CON100 housing SELV 59.4 59.2 58.9 51.3 71.6 - Heatsink left 83.3 70.9 66.4 85.8 85.5 - Heatsink right 82.3 81.6 81.1 61.4 92.2 - Front Bezel 54.5 53.5 53.0 53.1 68.1 - T101 core_coil 76.4 75.8 75.3 60.5 87.2 90 Metal chassis top 67.7 66.3 65.1 57.3 79.4 - Flatpack2 2000W 48V BF Test:

S-c outputInput: 184.5Vac, 0.9A, 50Hz Output: 0.04Vdc, 39.4A

Test Overload Input: 184.8Vac, 12.3A, 50Hz Output: 49.5Vdc, 40.4A

Test: Blocked fan Input: 188.7Vac, 10.9A, 50Hz Output: 50.7Vdc, 36.0A

Test: Ventilation blocked Input: 186.6Vac, 10.8A, 50Hz Output: 50.3Vdc, 35.7A

Test: NTC 200 disconnected Input: 187.1ac, 9.4A, 50Hz Output: 46.7Vdc, 33.3A

-

Ambient 55.1 50.1 50.2 66.4 64.8 - Con100 housing 57.6 53.7 57.8 60.1 67.8 -

Page 48: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 45 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

C100 56.0 52.3 56.0 59.7 66.6 - L100 winding 55.8 66.1 72.8 70.4 74.9 - C101 55.9 56.4 63.9 62.3 69.3 - L101 56.3 74.5 86.0 77.6 80.2 - F100 56.2 67.4 75.7 70.0 75.8 - T202 core 73.3 79.4 69.1 86.8 87.6 150 C102 56.3 61.3 71.1 66.5 72.4 - L102 57.2 70.5 86.7 74.2 77.9 - PWB near CON100 58.7 56.3 60.5 62.9 69.3 - PWB near DB100 57.7 73.0 86.0 78.5 80.8 - C200 top 58.5 64.0 79.0 69.2 74.1 - C113 top 63.1 64.2 73.2 70.4 76.4 - L200 core 81.3 78.4 97.2 82.9 85.4 - L200 coil 80.3 81.4 112.3 88.3 93.0 - T202 coil 70.2 73.2 65.1 80.1 83.2 150 T200 coil 91.3 94.0 101.8 95.2 97.9 190 T200 core 79.4 86.6 93.2 89.4 92.5 190 T201 coil 82.4 81.7 88.5 83.6 88.8 190 C213 top 65.0 60.3 69.8 63.7 73.0 - T100 core_coil 81.4 75.5 86.2 80.8 85.3 - L202 winding 65.5 60.9 67.1 63.1 72.9 - PWB near L202 68.1 64.5 71.3 68.5 75.7 - CON100 housing SELV 65.0 59.6 64.3 64.5 71.6 - Heatsink left 61.3 81.6 104.2 88.7 82.8 - Heatsink right 85.7 85.5 91.5 91.8 93.1 - Front Bezel 57.2 54.6 52.8 75.1 67.8 - T101 core_coil 83.8 78.9 87.8 84.4 88.2 - Metal chassis top 69.0 68.8 77.5 77.1 80.3 - Flatpack2 2000W 48V BF Test:

NTC 201 disconnected Input: 186.6ac, 12.1A, 50Hz Output: 52.9Vdc, 37.6A

- - - - -

Ambient 64.9 - - - - - Con100 housing 68.7 - - - - -

Page 49: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 46 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

C100 67.5 - - - - - L100 winding 81.4 - - - - - C101 71.8 - - - - - L101 89.7 - - - - - F100 83.3 - - - - - T202 core 97.4 - - - - 150 C102 76.7 - - - - - L102 86.8 - - - - - PWB near CON100 71.0 - - - - - PWB near DB100 86.6 - - - - - C200 top 79.2 - - - - - C113 top 81.4 - - - - - L200 core 92.8 - - - - - L200 coil 101.9 - - - - - T202 coil 91.1 - - - - 150 T200 coil 107.8 - - - - 190 T200 core 102.1 - - - - 190 T201 coil 96.1 - - - - 190 C213 top 75.9 - - - - - T100 core_coil 90.1 - - - - - L202 winding 75.3 - - - - - PWB near L202 78.7 - - - - - CON100 housing SELV 73.4 - - - - - Heatsink left 93.4 - - - - - Heatsink right 100.4 - - - - - Front Bezel 69.4 - - - - - T101 core_coil 94.1 - - - - - Metal chassis top 86.4 - - - - - Flatpack2 2000W 48V BF Test:

Locked rotor on fan Sanyo Denki, type 9GV0412J301

- - - - -

Ambient 21.8 - - - - - Fan case 37.2 - - - - - temperature T of winding: R1 (Ω) R2 ( Ω) T (°C) allowed

Tmax (°C)insulation

class

supplementary information:

Page 50: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 47 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

4.7 TABLE: resistance to fire Pass

part manufacturer of material type of material thickness(mm) flammability class

supplementary information:

5.2 TABLE: electric strength tests, impulse tests and voltage surge tests Pass

test voltage applied between: test voltage (V) a.c./d.c.

breakdown Yes / No

Flatpack2 1800W 48V - - Primary -SELV 4243 Vdc No Primary - Earth 2121 Vdc No T200/T201: One layer of insulation 4243 Vdc No BobbinT202: 4243 Vdc No Insulation between components and heat sink 2121 Vdc No Insulation between chassis and PWB 2121 Vdc No Flatpack2 2000W 48V and Flatpack2 2000W 48V BF - - Primary - Earth 2400 Vdc No Insulation between components and heat sink 2400 Vdc No Insulation between chassis and PWB 2400 Vdc No Flatpack2 24V - - Primary -SELV 4250 Vdc No Primary - Earth 2650 Vdc No T200/T201: One layer of insulation 4250 Vdc No BobbinT202: 4250 Vdc No Insulation between components and heat sink 2650 Vdc No Insulation between chassis and PWB 2650 Vdc No All models - - Insulation Formex GK-5BK 5000 Vdc* No Insulation Formex GK-10 5000 Vdc* No Insulation Formex GK-17 5000 Vdc* No supplementary information:

5.3 TABLE: fault condition tests Pass ambient temperature (°C) ....................................... : See below — model/type of power supply.................................... : See below — manufacturer of power supply ................................ : Eltek Energy A/S — rated markings of power supply ............................. : 1) Flatpack2 1800 W 48V:

Input: 230 Vac, 45-66 Hz, 11.0 Amax

Page 51: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 48 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Output: 53.5 Vdc, 33.6 A 2) Flatpack2 2000 W 48V and Flatpack2 2000W 48V BF: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A 3) Flatpack2 24 V: Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output 26.7 Vdc, 75 A

component No.

fault test voltage (V)

test time fuse No.

fuse current (A)

result

Flatpack2 2000W 48V BF

- - - - - -

PSU Blocked ventilation

186V - F100, F101

10.8 See heating test results for details. Power supply shuts down output at 75°C ambient, due to high internal temperature. At ambient temperature at 50°C max. temperature is 95.2°C on T200. No hazard

PSU Blocked fan 188V - F100, F101

10.9 See heating test results for details. Power supply shuts down output at 75°C ambient, due to high internal temperature. At ambient temperature at 50°C max. temperature is 101.8°C on T200. No hazard

NTC100 on main PWB

dis 185V - F100, F101

0 Output shutdown immediately. No hazard

NTC200 on main PWB

dis 187V - F100, F101

9.4 See heating test results for details. No hazard

NTC201 on main PWB

dis 186V - F100, F101

12.1 See heating test results for details. No hazard

Fan (Sanyo

Locked rotor 12 V 7h - - The Fan was operating with its rotor locked. Maximum

Page 52: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 49 of 49 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Denki) temperature measured on the housing was 41.3 °C

DC output S-c 185V 4h 1min F100, F101

0.9 Output dropped to 0V and measured output current was 39.4Adc. See heating test results for details. No hazard

DC output Overload 185V 1h 13min F100,F101

12.3 See heating test results for details. No hazard

supplementary information:

Page 53: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 2 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Underwriters Laboratories Inc.

Enclosure Miscellaneous

Supplement Id Description 7-01 Representative Label for 48 V, 1800W model 7-02 Representative Label for 48 V, 2000W model 7-03 Representive Label for 24 V, 2000W model 7-04 Alternate Label for 48 V, 2000 W model 7-05 Representive Label for Flatpack2 2000W 48V BF model

Page 54: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 2 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Underwriters Laboratories Inc.

Misc ID 7-05

Page 55: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 2 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Underwriters Laboratories Inc.

Enclosure Test Record

Description Test Record 1 Protective Earthing Trace Earth fault current test Test Record 2 Test Record 3 Test Record 4 Test datasheets CDR

Page 56: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 2 Report Reference # E177343-A19-UL-2Amendment 3 2006-11-20

Underwriters Laboratories Inc.

Test Record No. 4 The following tests conducted in accordance with UL 60950-1 were considered representative of the same tests required by Canadian Standard, CAN/CSA-C22.2 No. 60950-1-03 The manufacturer submitted representative production samples of Flatpack2 2kW 48V BF which was used for test purposes and is considered representative of the entire series of model Flatpack2 A B C BF.

The following tests were conducted: Test Testing Location/Comments Heating (4.5.1, 1.4.12, 1.4.13) Electric Strength (5.2.2) Component Failure (5.3.1, 5.3.4, 5.3.6) Abnormal Operation (5.3.1 - 5.3.8.2) Power Supply Output Short-Circuit/Overload (5.3.6) Locked-Rotor Overload for DC Motors in Secondary Circuits (Annex B.7)

Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report.

The following tests were waived: Test Rationale for Waiving Power Supply Reference Page

Page 57: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 3 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Copyright © 2006 Underwriters Laboratories Inc.

COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical

Business Equipment Product Category CCN: QQGQ2, QQGQ8 Test Procedure: Component Recognition Product: Power Supply for building-in Model/Type Reference: Flatpack2 A B C

Where A is the output power of the unit and can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank. B is the output voltage of the unit and can be 24V or 48V or blank C can be any alphanumeric letters or blank for marketing purposes only.

Rating(s): 1800 W units with 48V output: Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2000 W units with 48 V output: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A or 50 Vdc, 40 A 1800 W units with 24V output: N/A 2000 W units with 24 V output: Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output: 26.7 Vdc, 75 A

Standards: UL 60950-1:2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003

Applicant Name and Address:

ELTEK ENERGY A/S GRAATERUDVEIEN 8 3036 DRAMMEN NORWAY

Page 58: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 3 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Copyright © 2006 Underwriters Laboratories Inc.

This Report includes the following parts, in addition to this cover page:

1. Specific Technical Criteria 2. Clause Verdicts 3. Critical Components 4. Test Results 5. Enclosures

Page 59: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 3 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Copyright © 2006 Underwriters Laboratories Inc.

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. Test Report By: Reviewed By:

Casper S. Larsen Jan J.Jensen Associate Project Engineer Senior Project Engineer UL International Demko A/S UL International Demko A/S

Page 60: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

SPECIFIC TECHNICAL CRITERIA

UL 60950-1, First Edition Information technology equipment - Safety-

Part 1: General Requirements

Report Reference No........................: E177343-A19-UL-2 Compiled by .....................................: Casper S. Larsen Reviewed by ....................................: Jan J.Jensen Date of issue ....................................: 2006-03-13 Standards .........................................: UL 60950-1:2003, First Edition

CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 Test procedure .................................: Component Recognition Non-standard test method ...............: N/A Test item description .......................: Power Supply for building-in Trademark ........................................:

Model and/or type reference ............: Flatpack2 A B C

Where A is the output power of the unit and can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank. B is the output voltage of the unit and can be 24V or 48V or blank C can be any alphanumeric letters or blank for marketing purposes only.

Rating(s) ...........................................: 1800 W units with 48V output: Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2000 W units with 48 V output: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A or 50 Vdc, 40 A 1800 W units with 24V output: N/A 2000 W units with 24 V output:

Page 61: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output: 26.7 Vdc, 75 A

Particulars: test item vs. test requirements Equipment mobility .................................................... : for building-in Operating condition ................................................... : continuous Mains supply tolerance (%) ....................................... : +10%, -15% (according to manufacturer specification)Tested for IT power systems ..................................... : Yes IT testing, phase-phase voltage (V) .......................... : 230 Vac Class of equipment ................................................... : Class I (earthed) Mass of equipment (kg) ............................................ : 1.80 kg Protection against ingress of water ........................... : IP X0

Possible test case verdicts: - test case does not apply to the test object ............. : N / A - test object does meet the requirement ................... : Pass - test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent

national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

Page 62: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

GENERAL PRODUCT INFORMATION: CA1.0 Report Summary CA1.1 N/A

CB1.0 Product Description CB1.1 The equipment under test is a switch mode power supply, intended to be used in a rack system.

The power supply converts 230 Vac to 24 Vdc (nominal) or 48 Vdc (nominal) and communicates with a controller through its own microprocessor. The unit (in a rack system) is typically used to supply other telecommunication equipment, like mobile phone exchanges etc.

CC1.0 Model Differences CC1.1 The 48 V, 1800 W version uses main board 101148 and the 48 V, 2000 W version uses the main

board 206425. The two main boards are identical except for minor changes to the layout and component configuration. Flatpack2 24 V is identical to Flatpack2 2000W 48 V, except for the output rating, and minor changes in the secondary circuit. Flatpack2 24V uses main board 106969.

CD1.0 Additional Information CD1.1 See cover page for production sites.

The product was investigated to the following additional standards: EN 60950-1:2001 (which includes all European national differences, including those specified in this test report). Flatpack2 24: Max VA measurements. V=29.1 Vdc, A=85.2, VA=2009 (measured at 25.5 V, 78.8 A) Flatpack2 2000W 48 V: Max VA measurements. V=56.7 Vdc, A=41.2, VA=2016 (measured at 53.06 V, 38.0 A) Changes made under E177343-A19-CB-3 amendment 2 was performed under SMT program.

CE1.0 Technical Considerations CE1.2 The product was submitted and tested for use at the maximum ambient temperature (Tma)

permitted by the manufacturer’s specification of: 75 °C CE1.3 The means of connection to the mains supply is: through a connector on the backplane CE1.4 The product is intended for use on the following power systems: IT, TN CE1.5 The equipment disconnect device is considered to be: For building-in, must be determined in the

end product. CE1.7 The product was investigated to the following additional standards: EN 60950-1:2001 (which

includes all European national differences, including those specified in this test report).

Page 63: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

CE1.12 The following were investigated as part of the protective earthing/bonding: Printed wiring board trace (refer to Enclosure - Pictures + Schematics + PWB for layouts)

CE1.14 The following are available from the Applicant upon request: Specific data sheets for LEDs that are used for indicating purposes and assumed to be inherently Class 1 operating in the 400 - 700 nm wavelength range., Installation (Safety) Instructions / Manual

CF1.0 Engineering Conditions of Acceptability CF1.1 For use only in or with complete equipment where the acceptability of the combination is

determined by Underwriters Laboratories Inc. When installed in an end-product, consideration must be given to the following:

CF2.0 The end-product Electric Strength Test is to be based upon a maximum working voltage of: 224 Vrms, 488 Vpk on Flatpack2 1800W 48V and 294Vrms, 568Vp for Flatpack2 2000W 48V and 270 Vrms, 690 Vp for Flatpack2 24V.

CF2.1 The following secondary output circuits are SELV: 48 V output for Flatpack2 1800W 48V and Flatpack2 2000W 48V. 24 V output for Flatpack2 24V.

CF2.2 The following secondary output circuits are at hazardous energy levels: 48 Vdc output (Flatpack2 1800W 48V, Flatpack2 2000W 48V), and 24 Vdc output (Flatpack2 24V).

CF2.3 The power supply terminals and/or connectors are: Suitable for factory wiring only CF2.4 The maximum investigated branch circuit rating is: 20 A CF2.5 The investigated Pollution Degree is: 2 CF2.6 The front bezel complies with the requirements for: 5V ratings CF2.7 Proper bonding to the end-product main protective earthing termination is: Required CF2.8 An investigation of the bonding terminals as protective earthing terminals has: Been conducted CF2.9 The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2

insulation system with the indicated rating greater than Class A (105°C): T200 and T201 (Class F).

CF3 The following end-product enclosures are required: Electrical, Fire

Page 64: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.7.1 Rated current (mA or A) ........................................ : 1800 W units with 48V output: Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2000 W units with 48 V output: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A or 50 Vdc, 40 A 1800 W units with 24V output: N/A 2000 W units with 24 V output: Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output: 26.7 Vdc, 75 A

Pass

Type/model or type reference ............................... : Flatpack2 A B C Where A is the output power of the unit and can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank B is the output voltage of the unit and can be 24V or 48V or blank C can be any alphanumeric letters or blank for marketing purposes only.

Pass

Page 65: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.5.1 TABLE: list of critical components Pass

Object/part No. Manufacturer/ trademark

type/model technical data Product Category CCN(s)

Required Marks of Conformity

Supplement ID

Common components in Flatpack2 familiy

- - - - -

Enclosure (Bottom) (mech/fire)

Various Metal min 1 mm thick - -

Enclosure (Top) (mech/fire)

Various Aluminum min 1.9 mm thick - -

Heat sink (left and Right side)

Various (metal material) min 5 mm thick. See enclosure for details.

- -

Front Bezel LG Chemical Ltd GN-5001TF 5V, min 1.5 mm thick. See enclosure for details.

QMFZ2 -

Face plate (Decorative part)

LG Chemical Ltd GN-5001TF HB, min 0.8mm thick. Tested according to HB75

QMFZ2 -

Capacitor (C100, C108) Arcotronics R.46 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Vishay F1772 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C103, C104, C138,C139)

Murata Type KH Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139) Alternate

Matsushita Type TS Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139)

Vishay WYO Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Page 66: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 7 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Alternate Capacitor (C103, C104, C138,C139) Alternate

Xiamen Faratronic MKP62 Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139) Alternate

TDK CS Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C142) Arcotronics R.41 Line-to-Earth; 250 V, 22 nF

FOKY2 UL

Capacitor (C142) Alternate

Evox Rifa PME271Y Line-to-Earth; 250 V, 22 nF

FOKY2 UL

Inductor (L100, L101) Eltek Energy AS 103293 or 106125 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L100) Alternate

Eltek Energy AS 106347 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L100) Alternate

Eltek Energy AS 208257 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Fuse (F100, F101) Littelfuse 324015 Rated: 250 V, 15 A

JDYX2 -

Fuseholder Ashadi Glass Matex Co., Ltd.

RG-40JA Rated V-0, Min. 1.0mm thick QMFZ2 UL

Fuseholder Alternate

Chevron Philips R-7 02 Rated V-0, Min. 1.0mm thick QMFZ2 UL

Varistor (VDR100) Epcos S14K420 420V (line-to-line) XUHT2 UL Relay (REL100) Various Various Contact rated:

250 V, 16 A

NLDX2 UL

Page 67: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 8 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Coil rated: 12 Vdc

Inductor (L102) Eltek Energy AS 106077 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L102) Alternative

Eltek Energy AS 101545 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Voltage Regulator (U100)

National Semiconductor

LM317AT Rated 1.2 - 37 V, 1.5 A

- -

Voltage Regulator (U100) Alternate

On Semiconductor LM317BT Rated 1.2 - 37 V, 1.5 A

- -

Transformer (T202) Eltek Energy AS 101543 Open type construction Class A insulation system Copper magnet winding wound on split bobbin See enclosure for details.

- -

Opto Coupler (ISO200, ISO201, ISO202)

Vishay TCLT1003 Double protection, provides 3750 Vac isolation

FPQU2 UL

Opto Coupler (ISO200, ISO201, ISO202) Alternate

Infineon SFH6156 (System H and J)

Double protection, provides 4420 Vac isolation

FPQU2 UL

Connector (CON 100) (Primary and SELV)

Elcon / Tyco 284-0472-15000C Rated: 250 V, 35 A

ECBT2, RTRT2 UL

Page 68: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 9 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Insulation between metal enclosure and PWB And above electrolytic capacitors

Dupont Melinex 226 Minimum 0.188 mm thick, rated VTM-2.

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Toray Lumirror S10 Minimum 0.188 mm thick, rated VTM-2.

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Dupont Nomex 410 Minimum 0.188 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-5BK Minimum 0.12 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-10 Minimum 0.25 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-17 Minimum 0.43 mm thick, rated V-0

QMFZ2 -

Page 69: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 10 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Insulation between Switch transistors/diodes and HeatSink

Pioneer Conductor Rubber

PMP-P-100 Min. 0.15mm thick, rated V-0, 150°C

QMFZ2 (E153203)

-

Insulation between Switch transistors/diodes and HeatSink Alternate

Pioneer Conductor Rubber

PMP-P-500A 0.16 – 0.18mm thick, rated V-0, 150°C

QMFZ2 (E153203)

-

Insulation between Switch transistors/diodes and HeatSink Alternate

Richain GTR-B (Made of material provide by Pioneer Conductor Rubber, type PMP-P-400)

Min. 0.42mm thick, rated V-0, 150°C

QMFZ2 (E153203)

-

Insulation between Switch transistors/diodes and HeatSink Alternate

Kunze KU 7-724/C45/CP(Made of material provide by Shin-Etsu Chemical Co., Ltd, type TC-45C)

Min. 0.42mm thick, rated V-0, 150°C

QMFZ2 (E48923) -

Insulation between Switch transistors/diodes and HeatSink Alternate

Kunze KU-KG2.5 (Made of material provide by E I DuPont, type Kapton 100MT)

Min. 0.025mm thick, rated V-0, 200°C

QMFZ2 (E39505) -

PWB Various Various Rated:V-0, 130°C ZPMV2 UL Components in Flatpack2 1800W 48V only

- - - - -

Page 70: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 11 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Transformer (T200, T201)

Eltek 105103 Open type construction Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

OBJY2 -

Fan (Two provided) Sanyo Denki 109P0412J3153 Rated: 16.3CFM 12 Vdc, 0.35 A

GPWV2 UL

Fan (Two provided) Alternate

Sunon PMO1204PQB1-A

Rated: 17.6 CFM 12 Vdc, 0.39 A

GPWV2 UL

Rectifier (DB100) Rectron RS1507M Rated min. 1000 V, 15 A - - Rectifier (DB100) Alternate

Wontop GBJ15M Rated min. 1000 V, 15 A - -

Diode (D104) Infineon SDT12S60 Rated min. 600 V, 12 A - - Electrolytic Capacitors (C110-C114, C200)

Various Various Rated: 450 V, 150 uF, 105 C

- -

Switch Transistor (Q103) Infineon Q67040-S4491 (SPW47N60C3)

Rated min. 600 V, 47 A - -

Page 71: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 12 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Switch Transistor (Q105) Fairchild FQA19N60 Rated min. 600 V, 19 A - - Switch Transistor (Q200, Q201)

Infineon SPW32N50C3 Rated min. 500 V, 32 A - -

Inductor (L200) Eltek 104697 Open type construction Copper magnet winding wound on bobbin See enclosure for details.

- -

Transformer (T100, T101)

Eltek 102620 Open type construction. Core: Ferrite. Outer diameter 17 mm, Inner diameter 9 mm, width 7 mm including coil. Coil: Triple insulated wire Furukawa Electric, Type: TEX-E. See enclosure for details.

- -

Electrolytic Capacitors (C211-C215, C217)

Various Various Rated: 63 V, 470 uF, 105 C

- -

Components in Flatpack2 2000W 48V only

- - - - -

Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Transformer (T200, T201)

Eltek 105103 Open type construction

OBJY2 -

Page 72: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 13 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

Fan (Two provided) Sanyo Denki 109P0412J3153 Rated: 16.3CFM 12 Vdc, 0.35 A

GPWV2 UL

Fan (Two provided) Alternate

Sunon PMO1204PQB1-A

Rated: 17.6 CFM 12 Vdc, 0.39 A

GPWV2 UL

Rectifier (DB100) Wontop elctronics GBJ25M Rated min. 1000 V, 25 A - - Rectifier (DB100) Alternate

Rectron RS2507M Rated min. 1000 V, 25 A - -

Inductor (L103) KASCHKE KG GMBH & CO.

060.166 Copper magnet wire wound on ferrite core. See enclosure 4-09 for details

- -

Inductor (L103) Alternate

Eltek 206380 Copper magnet wire wound on ferrite core. See enclosure 4-14 for details

- -

Diode (D103) Fairchild Semiconductor

ISL9R460PF2 Rated min. 600 V, 4 A - -

Diode (D104) ST Microelectronics STTH30R06CW Rated min. 600 V, 15 A - - Electrolytic Capacitors (C112-C114, C200)

Various Various Rated: 450 V, 220 uF, 105 C

- -

Switch Transistor (Q103) Infineon SPW35N60C3 Rated min. 600 V, 34 A - -

Page 73: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 14 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Switch Transistor (Q105) Fairchild Semiconductor

FCP7N60 Rated min. 600 V, 7 A - -

Switch Transistor (Q200, Q201)

Infineon SPW47N60C3 Rated min. 600 V, 47 A - -

Capacitor (C105) Murata KX Line-to-Earth; 250 V, 1nF

FOWX2 UL

Capacitor (C105) Alternate

Murata KH Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Matsushita Type TS Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Vishay WYO Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Xiamen Faratronic MKP62 Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

TDK CS Line-to-Earth; 250 V, 1nF

FOKY2 UL

Inductor (L200) Eltek 204274 Open type construction Copper magnet winding wound on bobbin See enclosure for details.

- -

Transformer (T100, T101)

Eltek 204667 Open type construction. Core: Ferrite. Copper magnet winding wound on bobbin See enclosure for details.

- -

Page 74: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 15 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Electrolytic Capacitors (C211-C215, C217, C232, C236)

Various Various Rated: 63 V, 470 uF, 105 C

- -

Components in Flatpack2 24V only

- - - - -

Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Transformer (T200, T201)

Eltek 105169 Open type construction Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

OBJY2 -

Fan (Two provided) Sanyo Denki 9GV0412J301 Rated: 23.6CFM 12 Vdc, 0.6 A

GPWV2 UL

Fan (Two provided) Alternate

Sunon PMD1204PQB1-A Rated: 23.5 CFM 12 Vdc, 0.58 A. Blade: V-0

GPWV2 UL

Rectifier (DB100) Wontop elctronics GBJ25M Rated min. 1000 V, 25 A - - Rectifier (DB100) Alternate

Rectron RS2507M Rated min. 1000 V, 25 A - -

Diode (D104) Infineon SDT12S60 Rated min. 600 V, 12 A - -

Page 75: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 16 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Diode (D104) Alternate

ST Microelectronics STTH30R06CW Rated min. 600 V, 15 A - -

Electrolytic Capacitors (C110, C111, C113, C114, C200)

Various Various Rated: 450 V, 150 uF, 105 C

- -

Switch Transistor (Q103,Q106)

ST Microelectronics STW45NM60 Rated min. 600 V, 45 A - -

Switch Transistor (Q105) Fairchild Semiconductor

FCP7N60 Rated min. 600 V, 7 A - -

Switch Transistor (Q200, Q201)

Infineon SPW52N50C3 Rated min. 500 V, 52 A - -

Switch Transistor (Q200, Q201) Alternate

Infineon SPW47N60C3 Rated min. 600 V, 47 A - -

Inductor (L200) Eltek 204274 Copper magnet wire wound on Toroid core. See enclosure for details.

- -

Transformer (T100, T101)

Eltek 102620 Open type construction. Core: Ferrite. Copper magnet winding wound on bobbin See enclosure for details.

- -

Electrolytic Capacitors (C211-C215, C217, C232, C236, C237)

Various Various Rated: 35V, 1500uF, 105 C

- -

Page 76: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 17 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

2.10.5 TABLE: distance through insulation measurements Pass

distance through insulation di at/of: Up (V)

test voltage (V) required di (mm)

di (mm)

Flatpack2 1800W 48V - - - - Thin sheet material used inside T200, T201 230 4243 2 layers 2 layers Split bobbin T202 230 4243 0.4 0.58 Insulation material between pwb and metal enclosure

230 2121 - 0.188

Insulation material between pwb and metal enclosure

230 2121 - 0.43

Insulation material between switch transistors/diodes and heat sink

230 2121 - 0.15

Flatpack2 2000W 48V - - - - Thin sheet material used inside T200, T201 568 4250 2 layers 2 layers Split bobbin T202 470 4250 0.4 0.58 Insulation between PWB and bottom of chassis 486 2450 - Min. 0.12 Insulation between PWB and top chassis 486 2450 - Min. 0.18 Insulation between switch transistors/diodes and Heat sink

486 2450 - 0.15

Flatpack2 24V - - - - Thin sheet material used inside T200, T201 690 4250 2 layers 2 layers Split bobbin T202 596 4250 0.4 0.58 Insulation between PWB and bottom of chassis 564 2650 - Min. 0.12 Insulation between PWB and top chassis 564 2650 - Min. 0.18 Insulation between switch transistors/diodes and Heat sink

564 2650 - 0.15

All models - - - - Insulation Formex GK-5BK (used as alternative insulation between PWB and chassis)

564 2650 - 0.12

Insulation Formex GK-10 (used as alternative insulation between PWB and chassis)

564 2650 - 0.25

Insulation Formex GK-17 (used as alternative insulation between PWB and chassis)

564 2650 - 0.43

Insulation Kunze, type KU 7-724/C45/CP (Shin-Etsu Chemical Co, type TC-45C) (used between Switch transistors/diodes and HeatSink) Alternate

564 2650 - 0.42

Insulation Richain, type GTR-B (Pioneer Conductor Rubber Industry, type PMP-P-400) (used between Switch transistors/diodes and

564 2650 - 0.42

Page 77: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 18 of 18 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

HeatSink) Alternate Insulation Kunze, type KU-KG2.5 (E I DuPont, type Kapton, 100MT) (used between Switch transistors/diodes and HeatSink) Alternate

564 2650 - 0.025

supplementary information:

Page 78: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 4 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

Enclosure Diagrams

Supplement Id Description 4-01 Main transformer T200/T201 4-02 Input choke L100/L101 4-03 Inductor L102 4-04 Inductor L200 4-05 Transformer T100/T101 4-06 Transformer T202 4-07 DC Common mode Choke L202 4-08 Top Cover, Bottom Cover and left/right Heat Sink 4-09 Inductor L103 (2000W version) 4-10 Transformer T100/T101 4-11 Inductor L200 (Flatpack2 2000 W 48V and Flatpack2 24V) 4-12 Main transformer T200/T201 (Flatpack2 24V) 4-13 Input Choke L100/L101 (Flatpack2 24V) 4-14 Inductor L103 (2000 W version) Alternate

Page 79: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 4 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

Diagrams ID 4-14

Page 80: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 4 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

Diagrams ID 4-14

Page 81: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 4 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

Diagrams ID 4-14

Page 82: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 2 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

Enclosure Miscellaneous

Supplement Id Description 7-01 Representative Label for 48 V, 1800W model 7-02 Representative Label for 48 V, 2000W model 7-03 Representive Label for 24 V, 2000W model 7-04 Alternate Label for 48 V, 2000 W model

Page 83: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 2 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

Misc ID 7-04

Page 84: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 2 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

Enclosure Test Record

Description Test Record 1 Protective Earthing Trace Earth fault current test Test Record 2 Test Record 3

Page 85: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 2 Report Reference # E177343-A19-UL-2Amendment 2 2006-08-25

Underwriters Laboratories Inc.

Test Record No. 3 The following changes made to the report were evaluated in accordance with UL 60950-1 and the following tests conducted in accordance with UL 60950-1 were considered representative of the same tests required by Canadian Standard, CSA CSA CAN/CSA-C22.2 NO. 60950-1 -03. In adding of alternate supplier of L103 to Flatpack 2 A B C, testing was not considered necessary based on that the alternate component has same or better ratings. Additionally testing of Flatpack 2 A B C was not considered necessary based upon previous evaluation under CB Scheme. The CB Scheme Test Certificate ref No. DK-9630-A2 and Report Ref. No.E177343-A19-CB-3 amendment 2 dated 2006-08-23 were prepared by UL International Demko. The following changes were made under the CB Scheme: Adding of alternative insulation between switch transistors/diodes and heatsink. Adding of alternate nominal output rating marked on rating label for 2000W/48 Voutput model due to marketing purposes, no constructional changes were made. Adding new alternate Rohs compliant part number to L100/L101. Construction of L100/L101 is still the same, the new part number is only for administrative purposes. Update the way the ratings of the models are given.

The following tests were conducted: Test Testing Location/Comments Transformer/Insulation Electric Strength (2.10.5.2, 2.9.5) See Electric strength test (5.2.2) Electric Strength (5.2.2) Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report.

Page 86: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 2 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Copyright © 2006 Underwriters Laboratories Inc.

COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical

Business Equipment Product Category CCN: QQGQ2, QQGQ8 Test Procedure: Component Recognition Product: Power Supply for building-in Model/Type Reference: Flatpack2 A B C

Where A can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank B can be 24V or 48V or blank C can be any alphanumeric letters or blank for marketing purposes only.

Rating(s): Flatpack2 1800W 48V: Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A Flatpack2 2000W 48V: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A Flatpack2 24V: Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output: 26.7 Vdc, 75 A

Standards: UL 60950-1:2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003

Applicant Name and Address:

ELTEK ENERGY A/S GRAATERUDVEIEN 8 3036 DRAMMEN NORWAY

This Report includes the following parts, in addition to this cover page:

1. Specific Technical Criteria 2. Clause Verdicts 3. Critical Components 4. Test Results 5. Enclosures

Page 87: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 2 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Copyright © 2006 Underwriters Laboratories Inc.

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. Test Report By: Reviewed By:

Casper S. Larsen Jan J. Jensen Associate Project Engineer Project Engineer UL International Demko A/S UL International Demko A/S

Page 88: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

SPECIFIC TECHNICAL CRITERIA

UL 60950-1, First Edition Information technology equipment - Safety-

Part 1: General Requirements

Report Reference No........................: E177343-A19-UL-2 Compiled by .....................................: Casper S. Larsen Reviewed by ....................................: Jan J. Jensen Date of issue ....................................: 2006-03-13 Standards .........................................: UL 60950-1:2003, First Edition

CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 Test procedure .................................: Component Recognition Non-standard test method ...............: N/A Test item description .......................: Power Supply for building-in Trademark ........................................: Model and/or type reference ............: Flatpack2 A B C

Where A can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank B can be 24V or 48V or blank C can be any alphanumeric letters or blank for marketing purposes only.

Rating(s) ...........................................: Flatpack2 1800W 48V: Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A Flatpack2 2000W 48V: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A Flatpack2 24V: Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output: 26.7 Vdc, 75 A

Page 89: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Particulars: test item vs. test requirements Equipment mobility .................................................... : for building-in Operating condition ................................................... : continuous Mains supply tolerance (%) ....................................... : +10%, -15% (according to manufacturer specification)Tested for IT power systems ..................................... : Yes IT testing, phase-phase voltage (V) .......................... : 230 Vac Class of equipment ................................................... : Class I (earthed) Mass of equipment (kg) ............................................ : 1.80 kg Protection against ingress of water ........................... : IP X0

Possible test case verdicts: - test case does not apply to the test object ............. : N / A - test object does meet the requirement ................... : Pass - test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent

national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

Page 90: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

GENERAL PRODUCT INFORMATION: CA1.0 Report Summary CA1.1 N/A

CB1.0 Product Description CB1.1 The equipment under test is a switch mode power supply, intended to be used in a rack system.

The power supply converts 230 Vac to 24 Vdc (nominal) or 48 Vdc (nominal) and communicates with a controller through its own microprocessor. The unit (in a rack system) is typically used to supply other telecommunication equipment, like mobile phone exchanges etc.

CC1.0 Model Differences CC1.1 The 48 V, 1800 W version uses main board 101148 and the 48 V, 2000 W version uses the main

board 206425. The two main boards are identical except for minor changes to the layout and component configuration. Flatpack2 24 V is identical to Flatpack2 2000W 48 V, except for the output rating, and minor changes in the secondary circuit. Flatpack2 24V uses main board 106969.

CD1.0 Additional Information CD1.1 See cover page for production sites.

The product was investigated to the following additional standards: EN 60950-1:2001 (which includes all European national differences, including those specified in this test report). Flatpack2 24: Max VA measurements. V=29.1 Vdc, A=85.2, VA=2009 (measured at 25.5 V, 78.8 A) Flatpack2 2000W 48 V: Max VA measurements. V=56.7 Vdc, A=41.2, VA=2016 (measured at 53.06 V, 38.0 A)

CE1.0 Technical Considerations CE1.2 The product was submitted and tested for use at the maximum ambient temperature (Tma)

permitted by the manufacturer’s specification of: 75 °C CE1.3 The means of connection to the mains supply is: through a connector on the backplane CE1.4 The product is intended for use on the following power systems: IT, TN CE1.5 The equipment disconnect device is considered to be: For building-in, must be determined in the

end product. CE1.7 The product was investigated to the following additional standards: EN 60950-1:2001 (which

includes all European national differences, including those specified in this test report). CE1.12 The following were investigated as part of the protective earthing/bonding: Printed wiring board

Page 91: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

trace (refer to Enclosure - Pictures + Schematics + PWB for layouts) CE1.14 The following are available from the Applicant upon request: Specific data sheets for LEDs that

are used for indicating purposes and assumed to be inherently Class 1 operating in the 400 - 700 nm wavelength range., Installation (Safety) Instructions / Manual

CF1.0 Engineering Conditions of Acceptability CF1.1 For use only in or with complete equipment where the acceptability of the combination is

determined by Underwriters Laboratories Inc. When installed in an end-product, consideration must be given to the following:

CF2.0 The end-product Electric Strength Test is to be based upon a maximum working voltage of: 224 Vrms, 488 Vpk on Flatpack2 1800W 48V and 294Vrms, 568Vp for Flatpack2 2000W 48V and 270 Vrms, 690 Vp for Flatpack2 24V.

CF2.1 The following secondary output circuits are SELV: 48 V output for Flatpack2 1800W 48V and Flatpack2 2000W 48V. 24 V output for Flatpack2 24V.

CF2.2 The following secondary output circuits are at hazardous energy levels: 48 Vdc output (Flatpack2 1800W 48V, Flatpack2 2000W 48V), and 24 Vdc output (Flatpack2 24V).

CF2.3 The power supply terminals and/or connectors are: Suitable for factory wiring only CF2.4 The maximum investigated branch circuit rating is: 20 A CF2.5 The investigated Pollution Degree is: 2 CF2.6 The front bezel complies with the requirements for: 5V ratings CF2.7 Proper bonding to the end-product main protective earthing termination is: Required CF2.8 An investigation of the bonding terminals as protective earthing terminals has: Been conducted CF2.9 The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2

insulation system with the indicated rating greater than Class A (105°C): T200 and T201 (Class F).

CF3 The following end-product enclosures are required: Electrical, Fire

Page 92: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.7.1 Rated current (mA or A) ........................................ : Flatpack2 1800 W 48V: 11.0 Amax Flatpack2 2000W 48V: 12.5 Amax for 2000W Flatpack2 24V: 13.5 Amax

Pass

Type/model or type reference ............................... : Flatpack2 A B C where A can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank. B can be 24V or 48V or blank. C can be any alphanumeric letters or blank.

Pass

2.1.1.7 Time-constant (s); measured voltage (V) .............. : 0 V after 1 sec. Tested on Flatpack2 1800W 48V. The result also cover Flatpack2 2000W 48V and Flatpack2 24V.

-

2.6.3.4 Resistance (Ohm) of earthing conductors and their terminations, test current (A) ................................. :

Flatpack2 48V: Inlet to chassis: 50 A for 4 min. 1800 W version:U= 0.7 V, R=14 mOhm 2000 W version: U=0.13V, R=2.6 mOhm Flatpack2 24V: Inlet to chassis: 50 A for 4 min. U=0.11V, R=2.2mOhm

Pass

5.1.6 Test voltage (V) ..................................................... : Flatpack2 48V: 1) 1800 W Version: 230 V, 60 Hz 2) 2000 W Version: 250 V, 50 Hz Flatpack2 24V: Same as 2)

-

Measured touch current (mA)................................ : Flatpack2 48V: -

Page 93: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1) 2.4 mA maximum 2) 1.9 mA maximum Flatpack2 24V: Same as 2)

Page 94: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 7 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.5.1 TABLE: list of critical components Pass

Object/part No. Manufacturer/ trademark

type/model technical data Product Category CCN(s)

Required Marks of Conformity

Supplement ID

Common components in Flatpack2 familiy

- - - - -

Enclosure (Bottom) (mech/fire)

Various Metal min 1 mm thick - -

Enclosure (Top) (mech/fire)

Various Aluminum min 1.9 mm thick - -

Heat sink (left and Right side)

Various (metal material) min 5 mm thick. See enclosure for details.

- -

Front Bezel LG Chemical Ltd GN-5001TF 5V, min 1.5 mm thick. See enclosure for details.

QMFZ2 -

Face plate (Decorative part)

LG Chemical Ltd GN-5001TF HB, min 0.8mm thick. Tested according to HB75

QMFZ2 -

Capacitor (C100, C108) Arcotronics R.46 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Vishay F1772 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C103, C104, C138,C139)

Murata Type KH Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139) Alternate

Matsushita Type TS Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139)

Vishay WYO Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Page 95: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 8 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Alternate Capacitor (C103, C104, C138,C139) Alternate

Xiamen Faratronic MKP62 Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139) Alternate

TDK CS Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C142) Arcotronics R.41 Line-to-Earth; 250 V, 22 nF

FOKY2 UL

Capacitor (C142) Alternate

Evox Rifa PME271Y Line-to-Earth; 250 V, 22 nF

FOKY2 UL

Inductor (L100, L101) Eltek Energy AS 103293 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L100) Alternate

Eltek Energy AS 106347 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L100) Alternate

Eltek Energy AS 208257 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Fuse (F100, F101) Littelfuse 324015 Rated: 250 V, 15 A

JDYX2 -

Fuseholder Ashadi Glass Matex Co., Ltd.

RG-40JA Rated V-0, Min. 1.0mm thick QMFZ2 UL

Fuseholder Alternate

Chevron Philips R-7 02 Rated V-0, Min. 1.0mm thick QMFZ2 UL

Varistor (VDR100) Epcos S14K420 420V (line-to-line) XUHT2 UL Relay (REL100) Various Various Contact rated:

250 V, 16 A

NLDX2 UL

Page 96: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 9 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Coil rated: 12 Vdc

Inductor (L102) Eltek Energy AS 106077 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L102) Alternative

Eltek Energy AS 101545 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Voltage Regulator (U100)

Nacional Semiconductor

LM317AT Rated 1.2 - 37 V, 1.5 A

- -

Voltage Regulator (U100) Alternate

On Semiconductor LM317BT Rated 1.2 - 37 V, 1.5 A

- -

Transformer (T202) Eltek Energy AS 101543 Open type construction Class A insulation system Copper magnet winding wound on split bobbin See enclosure for details.

- -

Opto Coupler (ISO200, ISO201, ISO202)

Vishay TCLT1003 Double protection, provides 3750 Vac isolation

FPQU2 UL

Opto Coupler (ISO200, ISO201, ISO202) Alternate

Infineon SFH6156 (System H and J)

Double protection, provides 4420 Vac isolation

FPQU2 UL

Connector (CON 100) (Primary and SELV)

Elcon / Tyco 284-0472-15000C Rated: 250 V, 35 A

ECBT2, RTRT2 UL

Page 97: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 10 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Insulation between metal enclosure and PWB And above electrolytic capacitors

Dupont Melinex 226 Minimum 0.188 mm thick, rated VTM-2.

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Toray Lumirror S10 Minimum 0.188 mm thick, rated VTM-2.

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Dupont Nomex 410 Minimum 0.188 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-5BK Minimum 0.12 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-10 Minimum 0.25 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-17 Minimum 0.43 mm thick, rated V-0

QMFZ2 -

Page 98: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 11 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Insulation between Switch transistors/diodes and HeatSink

Pioneer Conductor Rubber

PMP-P-100 Min. 0.15mm thick, rated V-0, 150°C

QMFZ2 -

Insulation between Switch transistors/diodes and HeatSink Alternate

Pioneer Conductor Rubber

PMP-P-500A 0.16 – 0.18mm thick, rated V-0, 150°C

QMFZ2 -

PWB Various Various Rated:V-0, 130°C ZPMV2 UL Components in Flatpack2 1800W 48V only

- - - - -

Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Transformer (T200, T201)

Eltek 105103 Open type construction Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

OBJY2 -

Fan (Two provided) Sanyo Denki 109P0412J3153 Rated: 16.3CFM 12 Vdc, 0.35 A

GPWV2 UL

Fan (Two provided)

Sunon PMO1204PQB1-A

Rated: 17.6 CFM

GPWV2 UL

Page 99: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 12 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Alternate 12 Vdc, 0.39 A Rectifier (DB100) Rectron RS1507M Rated min. 1000 V, 15 A - - Rectifier (DB100) Alternate

Wontop GBJ15M Rated min. 1000 V, 15 A - -

Diode (D104) Infineon SDT12S60 Rated min. 600 V, 12 A - - Electrolytic Capacitors (C110-C114, C200)

Various Various Rated: 450 V, 150 uF, 105 C

- -

Switch Transistor (Q103) Infineon Q67040-S4491 (SPW47N60C3)

Rated min. 600 V, 47 A - -

Switch Transistor (Q105) Fairchild FQA19N60 Rated min. 600 V, 19 A - - Switch Transistor (Q200, Q201)

Infineon SPW32N50C3 Rated min. 500 V, 32 A - -

Inductor (L200) Eltek 104697 Open type construction Copper magnet winding wound on bobbin See enclosure for details.

- -

Transformer (T100, T101)

Eltek 102620 Open type construction. Core: Ferrite. Outer diameter 17 mm, Inner diameter 9 mm, width 7 mm including coil. Coil: Triple insulated wire Furukawa Electric, Type: TEX-E. See enclosure for details.

- -

Electrolytic Capacitors (C211-C215, C217)

Various Various Rated: 63 V, 470 uF, 105 C

- -

Components in - - - - -

Page 100: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 13 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Flatpack2 2000W 48V only Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Transformer (T200, T201)

Eltek 105103 Open type construction Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

OBJY2 -

Fan (Two provided) Sanyo Denki 109P0412J3153 Rated: 16.3CFM 12 Vdc, 0.35 A

GPWV2 UL

Fan (Two provided) Alternate

Sunon PMO1204PQB1-A

Rated: 17.6 CFM 12 Vdc, 0.39 A

GPWV2 UL

Rectifier (DB100) Wontop elctronics GBJ25M Rated min. 1000 V, 25 A - - Rectifier (DB100) Alternate

Rectron RS2507M Rated min. 1000 V, 25 A - -

Inductor (L103) KASCHKE KG GMBH & CO.

060.166 Copper magnet wire wound on ferrite core. See enclosure for details

- -

Diode (D103) Fairchild ISL9R460PF2 Rated min. 600 V, 4 A - -

Page 101: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 14 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Semiconductor Diode (D104) ST Microelectronics STTH30R06CW Rated min. 600 V, 15 A - - Electrolytic Capacitors (C112-C114, C200)

Various Various Rated: 450 V, 220 uF, 105 C

- -

Switch Transistor (Q103) Infineon SPW35N60C3 Rated min. 600 V, 34 A - - Switch Transistor (Q105) Fairchild

Semiconductor FCP7N60 Rated min. 600 V, 7 A - -

Switch Transistor (Q200, Q201)

Infineon SPW47N60C3 Rated min. 600 V, 47 A - -

Capacitor (C105) Murata KX Line-to-Earth; 250 V, 1nF

FOWX2 UL

Capacitor (C105) Alternate

Murata KH Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Matsushita Type TS Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Vishay WYO Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Xiamen Faratronic MKP62 Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

TDK CS Line-to-Earth; 250 V, 1nF

FOKY2 UL

Inductor (L200) Eltek 204274 Open type construction Copper magnet winding wound on bobbin See enclosure for details.

- -

Transformer (T100, T101)

Eltek 204667 Open type construction. Core: Ferrite.

- -

Page 102: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 15 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Copper magnet winding wound on bobbin See enclosure for details.

Electrolytic Capacitors (C211-C215, C217, C232, C236)

Various Various Rated: 63 V, 470 uF, 105 C

- -

Components in Flatpack2 24V only

- - - - -

Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Transformer (T200, T201)

Eltek 105169 Open type construction Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

OBJY2 -

Fan (Two provided) Sanyo Denki 9GV0412J301 Rated: 23.6CFM 12 Vdc, 0.6 A

GPWV2 UL

Fan (Two provided) Alternate

Sunon PMD1204PQB1-A Rated: 23.5 CFM 12 Vdc, 0.58 A. Blade: V-0

GPWV2 UL

Rectifier (DB100) Wontop elctronics GBJ25M Rated min. 1000 V, 25 A - -

Page 103: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 16 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Rectifier (DB100) Alternate

Rectron RS2507M Rated min. 1000 V, 25 A - -

Diode (D104) Infineon SDT12S60 Rated min. 600 V, 12 A - - Diode (D104) Alternate

ST Microelectronics STTH30R06CW Rated min. 600 V, 15 A - -

Electrolytic Capacitors (C110, C111, C113, C114, C200)

Various Various Rated: 450 V, 150 uF, 105 C

- -

Switch Transistor (Q103,Q106)

ST Microelectronics STW45NM60 Rated min. 600 V, 45 A - -

Switch Transistor (Q105) Fairchild Semiconductor

FCP7N60 Rated min. 600 V, 7 A - -

Switch Transistor (Q200, Q201)

Infineon SPW52N50C3 Rated min. 500 V, 52 A - -

Switch Transistor (Q200, Q201) Alternate

Infineon SPW47N60C3 Rated min. 600 V, 47 A - -

Inductor (L200) Eltek 204274 Copper magnet wire wound on Toroid core. See enclosure for details.

- -

Transformer (T100, T101)

Eltek 102620 Open type construction. Core: Ferrite. Copper magnet winding wound on bobbin See enclosure for details.

- -

Electrolytic Capacitors (C211-C215, C217, C232, C236, C237)

Various Various Rated: 35V, 1500uF, 105 C

- -

Page 104: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 17 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.6.2 TABLE: electrical data (in normal conditions) Pass

fuse # I rated (A) U (V) P (W) I (mA) I fuse (mA) condition/status Flatpack2 1800W 48V

F100, F101

11.0 max 85, 50 Hz 810 9400 9400 Output load: 52.3 Vdc 13.3 A

F100, F101

11.0 max 100, 50 Hz 971 9700 9700 Output load: 52.3 16.0

F100, F101

11.0 max 120, 50 Hz 1278 11300 11300 Output load: 52.3 20.8

F100, F101

11.0 max 185, 50 Hz 1994 10700 10700 Output load: 52.0 33.6

F100, F101

11.0 max 220, 50 Hz 1982 9000 9000 Output load: 52.3 33.6

F100, F101

11.0 max 230, 50 Hz 1977 8600 8600 Output load: 52.3 33.6

F100, F101

11.0 max 240, 50 Hz 1960 8200 8200 Output load: 52.3 33.6

F100, F101

11.0 max 242, 50 Hz 1974 8100 8100 Output load: 52.3 33.6

F100, F101

11.0 max 254, 50 Hz 1976 7800 7800 Output load: 52.3 33.6

F100, F101

11.0 max 276, 50 Hz 1973 7100 7100 Output load: 52.3 33.6

F100, F101

11.0 max 85, 50 Hz 794 9200 9200 Output load: 48.1 14.0

F100, F101

11.0 max 100, 50 Hz 972 9700 9700 Output load: 48.1 17.4

F100, F101

11.0 max 120, 50 Hz 1284 11100 11100 Output load: 48.1 22.4

F100, F101

11.0 max 185, 50 Hz 2008 10900 10900 Output load: 48.1

Page 105: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 18 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

36.0 F100, F101

11.0 max 220, 50 Hz 1984 9000 9000 Output load: 48.1 36.0

F100, F101

11.0 max 230, 50 Hz 1985 8600 8600 Output load: 48.1 36.0

F100, F101

11.0 max 240, 50 Hz 1982 8300 8300 Output load: 48.1 36.0

F100, F101

11.0 max 242, 50 Hz 1980 8200 8200 Output load: 48.1 36.0

F100, F101

11.0 max 254, 50 Hz 1973 7800 7800 Output load: 48.1 36.0

F100, F101

11.0 max 264, 50 Hz 1970 7500 7500 Output load: 48.1 36.0

F100, F101

11.0 max 85, 60 Hz 807 9400 9400 Output load: 52.3 Vdc 13.1

F100, F101

11.0 max 100, 60 Hz 991 9800 9800 Output load: 52.3 16.3

F100, F101

11.0 max 120, 60 Hz 1270 11100 11100 Output load: 52.3 20.3

F100, F101

11.0 max 185, 60 Hz 1990 10700 10700 Output load: 52.0 33.6

F100, F101

11.0 max 220, 60 Hz 1976 9000 9000 Output load: 52.3 33.6

F100, F101

11.0 max 230, 60 Hz 1977 8600 8600 Output load: 52.3 33.6

F100, F101

11.0 max 240, 60 Hz 1975 8200 8200 Output load: 52.3 33.6

F100, F101

11.0 max 242, 60 Hz 1968 8100 8100 Output load: 52.3 33.6

F100, F101

11.0 max 254, 60 Hz 1972 7700 7700 Output load: 52.3 33.6

F100, F101

11.0 max 264, 60 Hz 1963 7500 7500 Output load: 52.3

Page 106: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 19 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

33.6 F100, F101

11.0 max 85, 60 Hz 796 9200 9200 Output load: 48.1 14.0

F100, F101

11.0 max 100, 60 Hz 983 9700 9700 Output load: 48.1 17.5

F100, F101

11.0 max 120, 60 Hz 1263 11000 11000 Output load: 48.1 22.0

F100, F101

11.0 max 185, 60 Hz 2005 10800 10800 Output load: 48.1 36.0

F100, F101

11.0 max 220, 60 Hz 1987 9100 9100 Output load: 48.1 36.0

F100, F101

11.0 max 230, 60 Hz 1978 8600 8600 Output load: 48.1 36.0

F100, F101

11.0 max 240, 60 Hz 1984 8300 8300 Output load: 48.1 36.0

F100, F101

11.0 max 242, 60 Hz 1990 8200 8200 Output load: 48.1 36.0

F100, F101

11.0 max 254, 60 Hz 1982 7800 7800 Output load: 48.1 36.0

F100, F101

11.0 max 264, 60 Hz 1974 7500 7500 Output load: 48.1 36.0

Flatpack2 2000W 48V

F100/ F101

12.5 max 85, 50Hz 976 11450 11450 Normal load: 53.3V, 15.6A

F100/ F101

12.5 max 100, 50Hz 1010 10100 10100 Normal load: 53.3V, 16.6A

F100/ F101

12.5 max 120, 50Hz 1345 11210 11210 Normal load: 53.2V, 22.4A

F100/ F101

12.5 max 185, 50Hz 2189 11850 11850 Normal load: 52.9V, 37.4A

F100/ F101

12.5 max 220, 50Hz 2161 9917 9917 Normal load: 52.9V, 37.4A

F100/ F101

12.5 max 230, 50Hz 2156 9451 9451 Normal load: 52.9V, 37.4A

F100/ 12.5 max 250, 50Hz 2152 8685 8685 Normal load:

Page 107: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 20 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

F101 53.0V, 37.3A F100/ F101

12.5 max 275, 50Hz 2133 7896 7896 Normal load: 53.0V, 37.3A

F100/ F101

12.5 max 85, 60Hz 977 11440 11440 Normal load: 53.3V, 15.6A

F100/ F101

12.5 max 100, 60Hz 1015 10110 10110 Normal load: 53.3V, 16.7A

F100/ F101

12.5 max 120, 60Hz 1347 11200 11200 Normal load: 53.2V, 22.3A

F100/ F101

12.5 max 185, 60Hz 2181 11730 11730 Normal load: 52.7V, 37.2A

F100/ F101

12.5 max 220, 60Hz 2171 9942 9942 Normal load: 53.0V, 37.4A

F100/ F101

12.5 max 230, 60Hz 2163 9504 9504 Normal load: 53.0V, 37.5A

F100/ F101

12.5 max 250, 60Hz 2151 8653 8653 Normal load: 53.0V, 37.4A

F100/ F101

12.5 max 275, 60Hz 2137 7852 7852 Normal load: 53.0V, 37.4A

Flatpack2 24V

F100/ F101

13.5 max 85, 50Hz 763 8910 8910 Normal load: 25.4V, 25.5A

F100/ F101

13.5 max 100, 50Hz 1005 10120 10120 Normal load: 25.5V, 33.7A

F100/ F101

13.5 max 120, 50Hz 1326 11110 11110 Normal load: 25.5V, 44.8A

F100/ F101

13.5 max 176, 50Hz 2315 13170 13170 Normal load: 25.4V, 78.4A

F100/ F101

13.5 max 220, 50Hz 2288 10440 10440 Normal load: 25.5V, 78.4A

F100/ F101

13.5 max 230, 50Hz 2282 9930 9930 Normal load: 25.5V, 78.4A

F100/ F101

13.5 max 250, 50Hz 2274 9140 9140 Normal load: 25.5V, 78.4A

F100/ F101

13.5 max 275, 50Hz 2263 8260 8260 Normal load: 25.5V, 78.3A

F100/ F101

13.5 max 85, 60Hz 766 8910 8910 Normal load: 25.4V, 25.5A

F100/ F101

13.5 max 100, 60Hz 1003 10090 10090 Normal load: 25.5V, 33.7A

F100/ F101

13.5 max 120, 60Hz 1324 11080 11080 Normal load: 25.5V, 44.9A

F100/ F101

13.5 max 176, 60Hz 2315 13160 13160 Normal load: 25.4V, 78.4A

F100/ F101

13.5 max 220, 60Hz 2291 10430 10430 Normal load: 25.5V, 78.4A

F100/ 13.5 max 230, 60Hz 2287 9960 9960 Normal load:

Page 108: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 21 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

F101 25.5V, 78.4A F100/ F101

13.5 max 250, 60Hz 2276 9120 9120 Normal load: 25.5V, 78.4A

F100/ F101

13.5 max 275, 60Hz 2264 8250 8250 Normal load: 25.5V, 78.3A

supplementary information:

2.10.3 and 2.10.4

TABLE: clearance and creepage distance measurements Pass

clearance cl and creepage distance dcr at/of:

Up (V)

U r.m.s. (V) required cl (mm)

cl (mm) required dcr (mm)

dcr (mm)

Flatpack2 1800W 48V L-N before fuse 325 230 2.0 2.5 2.5 2.5 T201: Pin 4 - Pin 5 488 224 4.2 6 5.0 6 Pin 4 - Pin 6&7* 424 198 4.2 6 5.0 6 Pin 4 - Pin 8 368 172 4.2 6 5.0 6 Pin 2&3* - Pin 5 384 192 4.2 6 5.0 6 Pin 2&3* - Pin 6&7* 304 171 4.2 6 5.0 6 Pin 2&3* - Pin 8 256 155 4.2 6 5.0 6 Pin 1 - Pin 5 320 171 4.2 6 5.0 6 Pin 1 - Pin 6&7* 264 161 4.2 6 5.0 6 Pin 1 - Pin 8 296 157 4.2 6 5.0 6 Pin 4 - Earth 272 171 2.0 6 2.5 6 Pin 5 - Earth 400 177 2.0 6 2.5 6 T200: Pin 4 - Pin 5 408 181 4.2 6 5.0 6 Pin 4 - Pin 6&7* 264 158 4.2 6 5.0 6 Pin 4 - Pin 8 318 163 4.2 6 5.0 6 Pin 2&3* - Pin 5 344 164 4.2 6 5.0 6 Pin 2&3* - Pin 6&7* 336 163 4.2 6 5.0 6 Pin 2&3* - Pin 8 376 182 4.2 6 5.0 6 Pin 1 - Pin 5 352 170 4.2 6 5.0 6 Pin 1 - Pin 6&7* 376 190 4.2 6 5.0 6 Pin 1 - Pin 8 360 196 4.2 6 5.0 6 Pin 4 - Earth 384 171 2.0 3.4 2.5 3.4 Pin 5 - Earth 208 63 2.0 3.4 2.5 3.4 T202 Pin 1 - Pin 6 324 176 4.0 7.8 5.0 7.8 Pin 1 - Pin 7 348 195 4.0 7.8 5.0 7.8 Pin 1 - Pin 8 364 216 4.0 7.8 5.0 7.8 Pin 2 - Pin 6 340 194 4.0 7.8 5.0 7.8 Pin 2 - Pin 7 324 190 4.0 7.8 5.0 7.8

Page 109: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 22 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin 2 - Pin 8 304 178 4.0 7.8 5.0 7.8 Pin 3 - Pin 6 424 192 4.0 7.8 5.0 7.8 Pin 3 - Pin 7 404 187 4.0 7.8 5.0 7.8 Pin 3 - Pin 8 384 182 4.0 7.8 5.0 7.8 Pin 4 - Pin 6 448 197 4.0 7.8 5.0 7.8 Pin 4 - Pin 7 432 177 4.0 7.8 2.5 7.8 Pin 4 - Pin 8 408 181 4.0 7.8 2.5 7.8 Pin 5 - Pin 6 464 197 4.0 7.8 2.5 7.8 Pin 5 - Pin 7 440 201 4.0 7.8 2.5 7.8 Pin 5 - Pin 8 420 191 4.0 7.8 2.5 7.8 Q103 Pin 1 - Earth 424 193 2.1 3.4 2.5 3.4 Pin 2 - Earth 392 208.5 2.1 3.4 2.5 3.4 Pin 3 - Earth 428 195.1 2.1 3.4 2.5 3.4 D104 Pin 1 - Earth 396 199.9 2.2 3.4 2.5 3.4 Pin 2 - Earth 544 358.3 2.2 3.4 2.5 3.4 Q105 Pin 1 - Earth 400 190.3 2.1 3.4 2.5 3.4 Pin 2 - Earth 436 199 2.1 3.4 2.5 3.4 Pin 3 - Earth 400 186.9 2.1 3.4 2.5 3.4 Q200 Pin 1 - Earth 360 213.5 2.2 3.4 3.8 3.8 Pin 2 - Earth 544 377.8 2.2 3.4 3.8 3.8 Pin 3 - Earth 364 212.1 2.2 3.4 3.8 3.8 Q201 Pin 1 - Earth 444 205 2.1 3.4 2.5 3.4 Pin 2 - Earth 348 186.8 2.1 3.4 2.5 3.4 Pin 3 - Earth 428 204.5 2.1 3.4 2.5 3.4 U100 Pin 1 - Earth 408 144.8 2.1 5.5 2.5 5.5 Pin 2 - Earth 420 196.2 2.1 5.5 2.5 5.5 Pin 3 - Earth 428 183.6 2.1 5.5 2.5 5.5 ISO 200 Pin 4 - Pin 1 404 192 4.0 8.2 5.0 8.2 Pin 3 - Pin 2 416 172 4.0 8.2 5.0 8.2 ISO 201 Pin 1 - Pin 3 428 188 4.0 8.2 5.0 8.2 Pin 2 - Pin 4 444 208 4.0 8.2 5.0 8.2 ISO 202 Pin 4 - Pin 1 412 191 4.0 8.2 5.0 8.2 Pin 3 - Pin 2 416 178 4.0 8.2 5.0 8.2 Flatpack2 2000W 48V L-N before fuse 354 250 2.0 2.5 2.5 2.5

Page 110: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 23 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

T201 Pin4 - Pin5 442 210 4.2 6.4 ***) 5.0 6.4 ***) Pin4 - Pin6, 7 378 195 4.0 6.4 ***) 5.0 6.4 ***) Pin4 - Pin8 406 196 4.0 6.4 ***) 5.0 6.4 ***) Pin2,3* - Pin5 410 195 4.0 6.4 ***) 5.0 6.4 ***) Pin2,3* - Pin6, 7* 406 195 4.0 6.4 ***) 5.0 6.4 ***) Pin2,3* - Pin8 454 210 4.2 6.4 ***) 5.0 6.4 ***) Pin1 - Pin5 402 193 4.0 6.4 ***) 5.0 6.4 ***) Pin1 - Pin6, 7 442 205 4.2 6.4 ***) 5.0 6.4 ***) Pin1 - Pin8 494 230 4.4 6.4 ***) 5.0 6.4 ***) Pin4 – Earth 370 195 2.0 4.7 2.5 4.7 Pin5 – Earth 92 55 2.0 4.9 2.5 4.9 T200 Pin4 - Pin5 426 193 4.2 8.0 **) 5.0 8.0 **) Pin4 - Pin6, 7 442 205 4.2 8.0 **) 5.0 8.0 **) Pin4 - Pin8 494 230 4.4 8.0 **) 5.0 8.0 **) Pin2,3* - Pin5 442 205 4.2 8.0 **) 5.0 8.0 **) Pin2,3* - Pin6, 7* 490 229 4.2 8.0 **) 5.0 8.0 **) Pin2,3* - Pin8 545 264 4.4 8.0 **) 5.4 8.0 **) Pin1 - Pin5 460 221 4.2 8.0 **) 5.0 8.0 **) Pin1 - Pin6, 7 516 254 4.4 8.0 **) 5.2 8.0 **) Pin1 - Pin8 568 294 4.6 8.0 **) 6.4 8.0 **) Pin5 – Earth 71.6 53.3 2.0 4.9 2.5 4.9 T202 Pin1 - Pin6 430 248 4.2 6.4 **) 5.0 6.4 **) Pin1 - Pin7 453 262 4.2 6.4 **) 5.4 6.4 **) Pin1 - Pin8 470 277 4.2 6.4 **) 5.8 6.4 **) Pin2 - Pin6 267 168 4.0 6.4 **) 5.0 6.4 **) Pin2 - Pin7 245 167 4.0 6.4 **) 5.0 6.4 **) Pin2 - Pin8 256 168 4.0 6.4 **) 5.0 6.4 **) Pin3 - Pin6 356 165 4.0 8.2 5.0 8.2 Pin3 - Pin7 367 166 4.0 8.4 5.0 8.4 Pin3 - Pin8 386 167 4.0 10.2 5.0 10.2 Pin4 - Pin6 364 166 4.0 8.2 5.0 8.2 Pin4 - Pin7 348 165 4.0 8.4 5.0 8.4 Pin4 - Pin8 370 166 4.0 10.2 5.0 10.2 Pin5 - Pin6 370 163 4.0 7.5 5.0 7.5 Pin5 - Pin7 350 160 4.0 7.5 5.0 7.5 Pin5 - Pin8 341 159 4.0 7.5 5.0 7.5 Q103 Pin1 - Earth 342 162 2.0 3.2 2.5 3.2 Pin2 - Earth 486 243 2.1 3.2 2.5 3.2 Pin3 - Earth 338 165 2.0 3.2 2.5 3.2 D104 Pin1 - Earth 450 244 2.1 2.5 2.5 3.0 Pin2 - Earth 450 337 2.1 2.9 3.5 4.0

Page 111: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 24 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Q105 Pin1 - Earth 326 156 2.0 5.6 2.5 5.6 Pin2 - Earth 358 164 2.0 5.6 2.5 5.6 Pin3 - Earth 322 155 2.0 5.6 2.5 5.6 Q200 Pin1 - Earth 338 162 2.0 5.0 2.5 5.0 Pin2 - Earth 442 259 2.1 5.0 2.7 5.0 Pin3 - Earth 338 165 2.0 5.0 2.5 5.0 Q201 Pin1 - Earth 446 264 2.1 5.0 2.7 5.0 Pin2 - Earth 442 338 2.1 5.0 3.6 5.0 Pin3 - Earth 438 259 2.1 5.0 2.7 5.0 U100 Pin1 - Earth 334 161 2.0 5.5 2.5 5.5 Pin2 - Earth 334 161 2.0 5.5 2.5 5.5 Pin3 - Earth 322 154 2.0 5.5 2.5 5.5 ISO200 Pin1-Pin3 345 175 4.0 7.0 5.0 7.0 Pin1-Pin4 326 157 4.0 7.0 5.0 7.0 Pin2- Pin3 334 160 4.0 7.0 5.0 7.0 Pin2- Pin4 330 157 4.0 7.0 5.0 7.0 Pin3 - Earth 346 173.3 2.0 4.1 2.5 4.1 ISO201 Pin1-Pin3 340 166 4.0 7.0 5.0 7.0 Pin1-Pin4 358 176 4.0 7.0 5.0 7.0 Pin2- Pin3 345 166 4.0 7.0 5.0 7.0 Pin2- Pin4 360 176 4.0 7.0 5.0 7.0 ISO202 Pin1-Pin3 340 164 4.0 7.0 5.0 7.0 Pin1-Pin4 325 155 4.0 7.0 5.0 7.0 Pin2- Pin3 340 164 4.0 7.0 5.0 7.0 Pin2- Pin4 326 154 4.0 7.0 5.0 7.0 Flatpack2 24V L-N before fuse 354 250 2.0 2.5 2.5 2.5 L - Earth 354 250 2.0 2.5 2.5 2.5 T201 Pin4 - Pin5 592 226 4.6 6.7 5.0 6.7 Pin4 - Pin6, 7 556 219 4.4 6.7 5.0 6.7 Pin4 - Pin8 552 220 4.4 6.7 5.0 6.7 Pin2,3* - Pin5 560 218 4.4 6.7 5.0 6.7 Pin2,3* - Pin6, 7* 564 213 4.4 6.7 5.0 6.7 Pin2,3* - Pin8 584 218 4.6 6.7 5.0 6.7 Pin1 - Pin5 576 215 4.6 6.7 5.0 6.7 Pin1 - Pin6, 7 604 222 4.6 6.7 5.2 6.7 Pin1 - Pin8 620 229 4.6 6.7 5.0 6.7

Page 112: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 25 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin4 - Earth 516 190 2.2 4.3 2.5 4.3 Pin5 - Earth 76 35.6 2.0 5.6 2.5 5.6 T200 Pin4 - Pin5 576 214 4.6 7.4 5.0 7.4 Pin4 - Pin6, 7 604 222 4.6 7.4 5.0 7.4 Pin4 - Pin8 624 229 4.6 7.4 5.0 7.4 Pin2,3* - Pin5 620 230 4.6 7.4 5.0 7.4 Pin2,3* - Pin6, 7* 648 236 4.8 7.4 5.0 7.4 Pin2,3* - Pin8 665 252 4.8 7.4 5.2 7.4 Pin1 - Pin5 645 246 4.8 7.4 5.0 7.4 Pin1 - Pin6, 7 670 259 4.8 7.4 5.4 7.4 Pin1 - Pin8 690 270 4.8 7.4 5.6 7.4 Pin5 - Earth 64.0 35.6 2.0 3.0 2.5 3.0 T202 Pin1 - Pin6 568 252 4.6 7.3 5.2 7.3 Pin1 - Pin7 584 266 4.6 7.3 5.6 7.3 Pin1 - Pin8 596 280 4.6 7.3 6.0 7.3 Pin2 - Pin6 440 184 4.2 7.3 5.0 7.3 Pin2 - Pin7 436 185 4.2 7.3 5.0 7.3 Pin2 - Pin8 436 189 4.2 7.3 5.0 7.3 Pin3 - Pin6 180 103 4.0 7.3 5.0 7.3 Pin3 - Pin7 204 105 4.0 7.3 5.0 7.3 Pin3 - Pin8 224 109 4.0 7.3 5.0 7.3 Pin4 - Pin6 208 105 4.0 7.3 5.0 7.3 Pin4 - Pin7 188 103 4.0 7.3 5.0 7.3 Pin4 - Pin8 204 103 4.0 7.3 5.0 7.3 Pin5 - Pin6 236 109 4.0 7.3 5.0 7.3 Pin5 - Pin7 216 104 4.0 7.3 5.0 7.3 Pin5 - Pin8 192 101 4.0 7.3 5.0 7.3 Q103 Pin1 - Earth 254 149 2.0 2.7 2.5 2.7 Pin2 - Earth 558 238 2.2 4.4 3) 2.5 4.4 3) Pin3 - Earth 258 145 2.0 3.6 4) 2.5 3.6 4) D104 Pin1 - Earth 552 237 2.2 3.6 4) 2.5 3.6 4) Pin2 - Earth 564 333 2.2 3.6 4) 3.5 3.6 4) Q105 Pin1 - Earth 224 134 2.0 3.6 4) 2.5 3.6 4) Pin2 - Earth 248 153 2.0 6.6 4) 2.5 6.6 4) Pin3 - Earth 224 134 2.0 3.6 4) 2.5 3.6 4) Q200 Pin1 - Earth 560 254 2.2 4.4 3) 2.6 4.4 Pin2 - Earth 564 332 2.2 3.6 4) 3.5 3.6 4) Pin3 - Earth 564 261 2.2 3.6 4) 2.7 3.6 4) Q201

Page 113: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 26 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin1 - Earth 256 148 2.0 3.6 4) 2.5 3.6 4) Pin2 - Earth 564 255 2.2 4.4 3) 2.6 4.4 Pin3 - Earth 256 146 2.0 3.6 4) 2.5 3.6 4) U100 Pin1 - Earth 208 131 2.0 4.1 4) 2.5 4.1 4) Pin2 - Earth 208 129 2.0 4.1 4) 2.5 4.1 4) Pin3 - Earth 196 124 2.0 4.1 4) 2.5 4.1 4) ISO200 Pin1-Pin3 - 2) - 2) 4.0 7.1 5.0 7.1 Pin1-Pin4 180 108 4.0 7.1 5.0 7.1 Pin2- Pin3 - 2) - 2) 4.0 7.1 5.0 7.1 Pin2- Pin4 180 108 4.0 7.1 5.0 7.1 Pin4 - Earth 204 126 2.0 4.1 1) 2.5 4.1 1) ISO201 Pin1-Pin3 204 123 4.0 7.1 5.0 7.1 Pin1-Pin4 216 135 4.0 7.1 5.0 7.1 Pin2- Pin3 204 123 4.0 7.1 5.0 7.1 Pin2- Pin4 220 144 4.0 7.1 5.0 7.1 ISO202 Pin1-Pin3 184 114 4.0 6.9 5.0 6.9 Pin1-Pin4 216 123 4.0 6.9 5.0 6.9 Pin2- Pin3 184 114 4.0 6.9 5.0 6.9 Pin2- Pin4 220 123 4.0 6.9 5.0 6.9 Comments *) Terminals directly connected to each other

**) Distance represents an internal measurement. For 2000W version: Measurement is performed with a refernce to earth and measured the difference between primary and seondary side of the measured

***) Corrected measurement

1) Distance is measured from Pin3, since this distance is the shortest

2) EUT shutsdown when pin3 is connected to the oscilloscope. Measurement considered similar as to pin4

3) Measured on top of pcb. A plastic insulation is mounted between top cover and bottom cover and maintance the distance.

4) Measured on bottom side of PCB, until it reach the metal bottom chassis.

Page 114: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 27 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

component. ISO203 is not mounted.

supplementary information:

2.10.5 TABLE: distance through insulation measurements Pass

distance through insulation di at/of: Up (V)

test voltage (V) required di (mm)

di (mm)

Flatpack2 1800W 48V - - - - Thin sheet material used inside T200, T201 230 4243 2 layers 2 layers Split bobbin T202 230 4243 0.4 0.58 Insulation material between pwb and metal enclosure

230 2121 - 0.188

Insulation material between pwb and metal enclosure

230 2121 - 0.43

Insulation material between switch transistors/diodes and heat sink

230 2121 - 0.15

Flatpack2 2000W 48V - - - - Thin sheet material used inside T200, T201 568 4250 2 layers 2 layers Split bobbin T202 470 4250 0.4 0.58 Insulation between PWB and bottom of chassis 486 2450 - Min. 0.12 Insulation between PWB and top chassis 486 2450 - Min. 0.18 Insulation between switch transistors/diodes and Heat sink

486 2450 - 0.15

Flatpack2 24V - - - - Thin sheet material used inside T200, T201 690 4250 2 layers 2 layers Split bobbin T202 596 4250 0.4 0.58 Insulation between PWB and bottom of chassis 564 2650 - Min. 0.12 Insulation between PWB and top chassis 564 2650 - Min. 0.18 Insulation between switch transistors/diodes and Heat sink

564 2650 - 0.15

All models - - - - Insulation Formex GK-5BK (used as alternative insulation between PWB and chassis)

564 2650 - 0.12

Insulation Formex GK-10 (used as alternative insulation between PWB and chassis)

564 2650 - 0.25

Insulation Formex GK-17 (used as alternative insulation between PWB and chassis)

564 2650 - 0.43

supplementary information:

Page 115: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 28 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

4.5 TABLE: temperature rise measurements Pass test voltage (V) ......................................... See

belowSee below

See below

See below

See below —

t1 (°C)........................................................ See below

See below

See below

See below

See below —

t2 (°C)........................................................ See below

See below

See below

See below

See below —

maximum temperature T of part/at: T (°C) allowed Tmax (°C)

Flatpack2 1800W 48V Input

Condition : 205 V, 50 Hz, 9.6A, 1960W, duration 2 hours ; Output Condition : 48.5 Vdc, 35.4 A

Input Condition : 240 V, 60 Hz, 8.3 A, 1976 W, duration 55 min ; Output Condition : 48.0 Vdc, 35.4 A

Input Condition : 240 V, 50 Hz, 8.3 A, 1970 W, duration 40 min ; Output Condition : 48 Vdc, 35.4 A

Ambient (t2) 27.6 27.9 27.5 -- 1. Connector CON100 (primary) (housing) 65.4 62.2 61.6 -- 2. X Capacitor C100 76.9 69.4 68.9 105 3. Inductor L100 (windings) 95.0 81.9 81.4 155 4. X Capacitor C101 65.0 59.8 59.2 105 5. Inductor L101 73.3 65.6 65.0 155 6. Fuse F100 66.1 60.4 59.8 -- 7. Not Connected -- -- -- -- 8. X Capacitor C102 51.9 49.9 49.3 105 9. Inductor L102 79.0 71.0 70.4 155 10. PWB near CON100 (Primary) didn’t work during this test

-- -- -- --

11. PWB near DB100 71.4 67.7 67.0 130

Page 116: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 29 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

12. Electrolytic Capacitor (top) C200 46.6 46.7 46.2 105 13. Electrolytic Capacitor (top) C113 38.2 38.9 38.5 105 14. Inductor L200 (core) 53.8 56.1 55.2 155 15. Inductor L200 (windings) 69.6 72.9 71.7 155 16. Transformer T202 (windings) 33.9 34.4 33.5 90 17. Main Transformer T200 (windings) 87.1 91.9 90.6 130 18. Main Transformer T200 (core) 68.8 71.8 70.6 130 19. Main Transformer T201 (windings) 102.2 108.7 107.5 130 20. Main Transformer T201 (core) 92.1 97.9 96.7 130 21. PWB near D207 87.6 92.5 91.6 130 22. Electrolytic capacitor C213 (top) 67.7 70.9 70.0 105 23. Inductor L201 (windings) 72.8 76.8 75.8 155 24. Inductor L202 (windings) 86.7 91.2 90.4 155 25. PWB near output connector CON100 (SELV)

89.3 93.3 92.5 130

26. Output connector CON100 (SELV) (housing)

85.2 89.1 88.2 --

27. Heat sink left 72.8 70 69.4 -- 28. Heat sink right 84.8 87.3 86.9 -- 29. Front bezel 27.5 28 26.8 95 Input

Condition: 205 V, 50 Hz, 9.7 A, 1965 W, duration 1 h 20 min; Output Condition: 48 Vdc, 36.1 A

Input Condition: 205 V, 50 Hz, 8.7 A, 1770 W, duration 55 min; Output Condition: 48 Vdc, 32.5 A

Input Condition: 205 V, 50 Hz, 6.7 A, 1350 W, duration 40 min; Output Condition: 47 Vdc, 25.4 A

Ambient (t2) 48.5 56.0 75.4 -- 1. Connector CON100 (primary) (housing) 70.6 75.5 90.2 -- 2. X Capacitor C100 83.3 86.4 98.5 105

Page 117: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 30 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

3. Inductor L100 (windings) 98.4 98.7 105.8 155 4. X Capacitor C101 74.4 78.8 93.3 105 5. Inductor L101 80.5 84.0 96.5 155 6. Fuse F100 76.2 80.2 93.9 -- 7. Not Connected -- -- -- -- 8. X Capacitor C102 65.2 71.3 88.4 105 9. Inductor L102 86.2 89.7 102.0 155 10. PWB near CON100 (Primary) 71.0 76.0 90.9 -- 11. PWB near DB100 73.4 78.5 93.7 130 12. Electrolytic Capacitor (top) C200 59.4 66.1 84.2 105 13. Electrolytic Capacitor (top) C113 56.1 63.0 81.3 105 14. Inductor L200 (core) 68.1 73.0 89.5 155 15. Inductor L200 (windings) 83.7 86.6 99.3 155 16. Transformer T202 (windings) 54.2 61.7 81.1 90 17. Main Transformer T200 (windings) 97.0 99.0 108.1 130 18. Main Transformer T200 (core) 79.8 84.2 97.4 130 19. Main Transformer T201 (windings) 105.6 106.6 114.8 130 20. Main Transformer T201 (core) 96.1 98.2 108.3 130 21. PWB near D207 90.4 92.8 103.2 130 22. Electrolytic capacitor C213 (top) 75.8 80.0 94.0 105 23. Inductor L201 (windings) 79.2 83.0 96.1 155 24. Inductor L202 (windings) 89.9 92.1 101.6 155 25. PWB near output connector C100 (SELV) 89.6 92.0 101.2 130 26. Output connector C100 (SELV) (housing) 86.6 89.3 99.6 -- 27. Heat sink left 77.1 81.6 94.8 -- 28. Ambient temperature inside heating chamber

48.5 56.0 75.4 --

29. Front bezel 48.8 56.3 75.8 95 Input

Condition: 205 V, 50 Hz, 9.7 A, 1980 W, duration 1 h 10 min ; Outpu

Input Condition: 205 V, 50 Hz, 9.7 A, 1960 W, duration 1 h 5 min; Output Condition: 48 Vdc,

Input Condition: 205 V, 50 Hz, 9.6 A, 1950 W, duration 50 min; Output Condition: 48 Vdc, 36 A

Input Condition: 205 V, 50 Hz, 9.3 A, 1890 W, duration 1 h 10 min ; Output Condition: 48 Vdc,

Input Condition: 210 V, 50 Hz, 0.7 A, 119 W, duration 1 h 25 min ; Output Condition:0.2 Vdc, 29.8 A (short-circuit of the

Page 118: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 31 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

t Condition: 48 Vdc, 36.3 A (short-circuit of NTC 200)

36 A (short-circuit of NTC 100 on primary side – main board)

(short-circuit of NTC 100 on primary side – main board)

35.1 A (short-circuit of NTC 100 on the small card)

output)

Ambient (t2) 48.1 49.2 75.7 47.9 75.0 -- 1. Connector CON100 (primary) (housing) 69.5 71.3 89.8 77.9 80.6 -- 2. X Capacitor C100 82.9 84.9 97.2 96.3 81.4 -- 3. Inductor L100 (windings) 99.2 102.2 105.7 115.4 81.5 -- 4. X Capacitor C101 74.4 77.0 92.9 87.4 81.4 -- 5. Inductor L101 79.9 82.6 96.4 93.8 81.4 -- 6. Fuse F100 75.5 77.8 93.6 86.6 81.4 -- 7. Not Connected -- -- -- -- -- -- 8. X Capacitor C102 64.6 66.0 87.8 72.8 81.5 -- 9. Inductor L102 85.3 88.0 102.0 101.8 82.6 -- 10. PWB near CON100 (Primary) 69.5 71.1 90.2 79.8 83.9 -- 11. PWB near DB100 71.8 61.4 97.4 65.6 81.8 -- 12. Electrolytic Capacitor (top) C200 59.6 60.2 83.2 65.7 80.6 -- 13. Electrolytic Capacitor (top) C113 55.4 57.0 80.9 59.7 79.8 -- 14. Inductor L200 (core) 67.3 69.0 88.8 74.5 104.8 -- 15. Inductor L200 (windings) 82.7 85.2 98.7 90.5 117.4 -- 16. Transformer T202 (windings) 53.6 55.0 80.5 55.0 79.9 150 17. Main Transformer T200 (windings) 97.5 99.6 108.2 109.1 105.2 190 18. Main Transformer T200 (core) 79.3 80.2 96.6 89.3 93.0 190 19. Main Transformer T201 (windings) 105.5 109.2 114.7 125.4 109.4 190 20. Main Transformer T201 (core) 94.6 98.3 107.8 114.5 103.8 190 21. PWB near D207 90.8 92.9 103.8 104.4 105.6 -- 22. Electrolytic capacitor C213 (top) 74.5 78.3 94.4 86.5 94.8 -- 23. Inductor L201 (windings) 79.1 80.9 96.3 91.6 97.2 -- 24. Inductor L202 (windings) 88.4 90.4 101.5 102.6 103.2 -- 25. PWB near output connector C100 (SELV) 89.0 91.7 102.0 100.0 103.8 -- 26. Output connector C100 (SELV) (housing) 85.8 88.1 99.9 96.4 101.4 -- 27. Heat sink left 79.6 83.6 100.5 87.2 82.0 -- 28. Ambient temperature inside heating chamber

48.1 49.2 75.7 47.9 75.0 --

29. Front bezel 48.6 49.6 75.8 48.2 75.1 -- Input

Condition:

Page 119: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 32 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

205 V, 50 Hz, 7.8 A, 1650 W, duration 1 h 40 min ; Output Condition: 48 Vdc, 31.5 A (blocked ventilation)

Ambient (t2) 45.1 -- 1. Connector CON100 (primary) (housing) 65.4 -- 2. X Capacitor C100 70.5 -- 3. Inductor L100 (windings) 88.4 -- 4. X Capacitor C101 85.9 -- 5. Inductor L101 98.6 -- 6. Fuse F100 89.7 -- 7. Not Connected -- -- 8. X Capacitor C102 96.1 -- 9. Inductor L102 122.7 -- 10. PWB near CON100 (Primary) 66.0 -- 11. PWB near DB100 83.4 -- 12. Electrolytic Capacitor (top) C200 91.7 -- 13. Electrolytic Capacitor (top) C113 94.0 -- 14. Inductor L200 (core) 127.9 -- 15. Inductor L200 (windings) 139.2 -- 16. Transformer T202 (windings) 94.0 150 17. Main Transformer T200 (windings) 131.0 190 18. Main Transformer T200 (core) 110.1 190 19. Main Transformer T201 (windings) 139.5 190 20. Main Transformer T201 (core) 128.2 190

Page 120: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 33 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

21. PWB near D207 121.7 -- 22. Electrolytic capacitor C213 (top) 101.6 -- 23. Inductor L201 (windings) 112.1 -- 24. Inductor L202 (windings) 94.9 -- 25. PWB near output connector C100 (SELV) 83.7 -- 26. Output connector C100 (SELV) (housing) 79.2 -- 27. Heat sink left 80.9 -- 28. Ambient temperature inside heating chamber

45.1 --

29. Front bezel 67.9 -- Transf

ormer T200 and T201 version 5: Input Condition: 264 Vac, 50 Hz, 7.4 A, 1945 W, Output Condition: 48 Vdc, 36.1 A

Transformer T200 and T201 version 5: Input Condition: 264 V, 50 Hz, 7.4 A, 1935 W, Output Condition: 52.7 Vdc, 33.1 A

Transformer T200 and T201 version 5: Input Condition: 87.2 Vac, 50 Hz, 8.4 A, 740 W, Output Condition: 47.2 Vdc, 13.2 A

Transformer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 10.5 A, 1965 W, Output Condition: 48 Vdc, 36.6 A

Transformer T200 and T201 version 5: Input Condition:264.7 Vac, 50 Hz, 6.9 A, 1807 W, Output Condition:47.7 Vdc, 33.9 A

Ambient (t2) 24.2 23.6 25.1 24.2 24.2 -- Humidity (2), RH (%) 21.9 27.4 25.5 24.2 16.3 -- 1. Ambient inside chamber -- -- -- 52.3 49.9 -- 3. Transformer T200 (bobbin) 52.9 53.5 43.3 71.3 69.1 130 4. Transformer T200 (windings) 70.4 70.5 52.3 86.1 83.7 130 5. Transformer T201 (bobbin) 67.9 68.0 52.0 80.9 78.6 130 6. Transformer T201 (windings) 72.0 70.7 51.4 84.4 82.0 130 7. PWB near T201 82.4 78.4 53.6 82.4 79.5 130 Transf

ormer T200

Transformer T200

Transformer T200

Transformer T200

Transformer T200 and T201

Page 121: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 34 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

and T201 version 5: Input Condition: 187 Vac, 50 Hz, 10 A, 1871 W, Output Condition: 47.7 Vdc, 35.1 A

and T201 version 5: Input Condition: 187 Vac, 50 Hz, 9.0 A, 1685 W, Output Condition: 48.3 Vdc, 31.1 A

and T201 version 5: Input Condition: 187.3 Vac, 50 Hz, 7.6 A, 1411 W, Output Condition: 48.1 Vdc, 26.4 A

and T201 version 5: Input Condition: 91 Vac, 50 Hz, 6.4 A, 580 W, Output Condition: 48.5 Vdc, 10.4 A

version 5: Input Condition: 264 Vac, 50 Hz, 5.5 A, 1452 W, Output Condition:48 Vdc, 27.5 A

Ambient (t2) 24.8 24.2 24.6 24.7 24.8 -- Humidity (2), RH (%) 16.8 18.7 17.5 17.1 16.8 -- 1. Ambient (Inside chamber) 52.0 59.7 74.8 74.4 74.4 -- 3. Transformer T200 (bobbin) 70.7 75.4 87.0 78.6 87.0 130 4. Transformer T200 (windings) 85.1 87.4 96.1 82.6 96.3 130 5. Transformer T201 (bobbin) 80.2 84.0 94.8 81.7 95.0 130 6. Transformer T201 (windings) 84.2 88.0 96.0 81.1 96.1 130 7. PWB near T201 81.4 84.2 93.7 78.6 90.7 130 Transf

ormer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 10 A, 1871 W, Outpu

Transformer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 9.0 A, 1685 W, Output Condition: 48.3

Transformer T200 and T201 version 5: Input Condition: 187.3 Vac, 50 Hz, 7.6 A, 1411 W, Output Condition:

Transformer T200 and T201 version 5: Input Condition: 91 Vac, 50 Hz, 6.4 A, 580 W, Output Condition: 48.5

Transformer T200 and T201 version 5: Input Condition:264 Vac, 50 Hz, 5.5 A, 1452 W, Output Condition:48 Vdc, 27.5 A

Page 122: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 35 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

t Condition: 47.7 Vdc, 35.1 A

Vdc, 31.1 A

48.1 Vdc, 26.4 A

Vdc, 10.4 A

Ambient (t2) 24.8 24.2 24.6 24.7 24.8 - Humidity (2), RH (%) 16.8 18.7 17.5 17.1 16.8 - 1. Ambient (Inside chamber) 52.0 59.7 74.8 74.4 74.4 - 3. Transformer T200 (bobbin) 70.7 75.4 87.0 78.6 87.0 130 4. Transformer T200 (windings) 85.1 87.4 96.1 82.6 96.3 130 5. Transformer T201 (bobbin) 80.2 84.0 94.8 81.7 95.0 130 6. Transformer T201 (windings) 84.2 88.0 96.0 81.1 96.1 130 7. PWB near T201 81.4 84.2 93.7 78.6 90.7 130 Transf

ormer T200 and T201 version 5: Input Condition: 264 Vac, 50 Hz, 7.4 A, 1931 W, Output Condition: 47.9 Vdc, 36.1 A

Transformer T200 and T201 version 5: Input Condition: 86.1 V, 50 Hz, 8.2 A, 706 W, Output Condition: 47.6 Vdc, 12.1 A

Ambient (t2) 25.3 25.2 - Humidity (2), RH (%) 15.9 19.2 - 1. Ambient (Inside chamber) 49.4 46.4 - 3. Transformer T200 (bobbin) 68.3 52.2 130 4. Transformer T200 (windings) 81.9 56.8 130 5. Transformer T201 (bobbin) 78.8 55.5 130

Page 123: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 36 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

6. Transformer T201 (windings) 82.3 55.1 130 7. PWB near T201 74.4 52.6 130 Transf

ormer T200 and T201 version 5: Input Condition: 187.7 V, 50 Hz, 3.3 A, 610 W, Output Condition: 11.5 Vdc, 37.5 A

Transformer T200 and T201 version 5: Input Condition: 189.6 V, 50 Hz, 0.9 A, 192 W, Output Condition (S/C): 0.2 Vdc, 36.4 A

Transformer T200 and T201 version 5: Input Condition: 187 V, 50 Hz, 10.5 A, 1050 W, Output Condition: 47.9 Vdc, 35.8 A (NTC100 SC on the small card)

Transformer T200 and T201 version 5: Input Condition: 187.9 V, 50 Hz, 10.5 A, 1966 W, Output Condition: 48.6 Vdc, 36.4 A (short-circuit of NTC 200)

Ambient (t2) 24.3 24.5 25.3 - Humidity (2), RH (%) 20.4 20.2 20.6 - 1. Ambient (Inside chamber) 48.8 47.3 44.3 23.8 - 3. Transformer T200 (bobbin) 67.0 64.4 75.0 68.9 190 4. Transformer T200 (windings) 80.5 77.4 86.9 76.5 190 5. Transformer T201 (bobbin) 77.6 74.6 85.6 76.3 190 6. Transformer T201 (windings) 84.4 81.7 88.8 92.2 190 7. PWB near T201 75.6 73.3 57.9 93.0 - Flatpack2 2000W 48V Input

Condition : 85 V, 50 Hz, 11.4A, 966W

Input Condition : 100 V, 50 Hz, 11.5A, 1118W, duration 7 h,

Input Condition : 185 V, 50 Hz, 11.7A, 2183W, duration 2 h,

Input Condition : 230 V, 50 Hz, 9.4A, 2155W, duration 1 h,

Input Condition : 250 V, 50 Hz, 8.7A, 2178W, duration 20min ; Output

Page 124: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 37 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

, duration 7 h, 48min ; Output Condition : 52.3 Vdc, 16.2 A

48min ; Output Condition : 51.9 Vdc, 18.8 A

28min ; Output Condition : 52.7 Vdc, 37.3 A

4min ; Output Condition : 52.7 Vdc, 37.3 A

Condition : 53.1 Vdc, 37.7 A

Con100 housing 62.9 63.9 71.4 66.8 65.5 - C100 67.8 68.5 73.8 66.8 65.0 105 L100 winding 78.0 78.9 84.1 72.4 69.4 155 C101 69.4 70.0 73.7 65.7 63.7 105 L101 80.5 81.4 86.0 73.0 69.8 155 F100 71.4 72.1 75.6 66.3 64.0 - T202 core 56.5 56.6 56.8 56.6 56.6 90 C102 60.9 61.3 63.6 59.3 58.2 105 L102 82.7 84.5 92.5 77.3 73.4 155 PWB near CON100 68.8 69.4 73.7 67.4 65.8 130 PWB near DB100 75.5 76.3 80.8 73.2 71.1 130 C200 top 56.9 57.3 59.7 57.1 56.5 105 C113 top 50.5 50.8 52.5 51.6 51.3 105 L200 core 53.9 55.4 67.4 67.0 66.9 155 L200 coil 60.3 63.6 90.0 89.6 89.6 155 T202 coil 52.8 52.8 52.6 52.4 52.3 90 T200 coil 59.4 61.7 83.7 83.5 83.7 130 T200 core 61.7 63.5 79.4 78.8 78.8 130 T201 coil 63.6 66.2 91.2 90.6 90.6 130 T201 core 62.1 64.1 83.7 83.0 82.9 130 PWB near D207 62.4 65.5 91.7 91.1 91.1 130 C213 top 56.6 58.0 70.0 69.1 68.9 105 T100 core/coil 54.3 54.7 56.6 56.5 56.4 90 L202 winding 58.6 60.8 82.0 81.2 81.0 155 PWB near L202 60.5 62.5 81.0 80.1 79.9 130 CON100 housing SELV 58.5 60.9 82.4 81.3 81.2 - Heat sink left 63.3 66.1 85.0 84.0 83.9 - Heat sink right 71.0 72.0 77.9 72.6 71.2 - Front bezel 46.2 46.3 45.5 45.5 45.5 95 T101 core/coil 51.0 51.3 52.8 52.8 52.7 90 Metal chassis top 58.9 59.4 64.2 61.8 61.0 - Ambient 45.0 44.8 43.2 43.9 44.1 - - Input Input - - - -

Page 125: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 38 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Condition : 275 V. 50 Hz. 7.8A. 2171W. duration 16 h. 39min ; Output Condition : 53.1 Vdc. 37.6 A

Condition : 185 V. 50 Hz. 7.5A. 1389W. duration 53min ; Output Condition : 43.8 Vdc. 28.7 A

Con100 housing 64.5 91.8 - - - - C100 63.3 91.8 - - - 105 L100 winding 66.5 95.7 - - - 155 C101 61.8 91.3 - - - 105 L101 66.6 96.5 - - - 155 F100 61.9 91.8 - - - - T202 core 56.5 83.0 - - - 90 C102 57.1 86.8 - - - 105 L102 69.4 99.4 - - - 155 PWB near CON100 64.0 92.3 - - - 130 PWB near DB100 68.9 96.7 - - - 130 C200 top 55.9 85.2 - - - 105 C113 top 51.1 80.7 - - - 105 L200 core 67.2 90.7 - - - 155 L200 coil 89.9 105.7 - - - 155 T202 coil 52.3 80.1 - - - 90 T200 coil 83.8 101.6 - - - 130 T200 core 78.8 99.3 - - - 130 T201 coil 90.6 106.4 - - - 130 T201 core 83.1 101.7 - - - 130 PWB near D207 91.0 108.1 - - - 130 C213 top 68.9 93.3 - - - 105 T100 core/coil 56.5 85.4 - - - 90 L202 winding 80.9 100.6 - - - 155 PWB near L202 79.7 100.2 - - - 130 CON100 housing SELV 80.8 100.5 - - - -

Page 126: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 39 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Heat sink left 83.7 103.9 - - - - Heat sink right 69.7 95.9 - - - - Front bezel 45.4 76.0 - - - 95 T101 core/coil 53.0 82.1 - - - 90 Metal chassis top 60.5 88.0 - - - - Ambient 43.6 74.8 - - - - - Input

Condition : 186 V. 50 Hz. 0.8A. 128W. duration 53min ; Output Condition : S-c. 0.6Vdc. 29.7 A

Input Condition : 190 V. 50 Hz. 8.5A. 1606W. duration 1 h. 45min ; Output Condition : Blocked ventilation.47.0 Vdc. 30.8 A

Input Condition : 190 V. 50 Hz. 8.5A. 1606W. duration 13min ; Output Condition : Blocked ventilation.41.5 Vdc. 30.8 A

Input Condition : 191 V. 50 Hz. 6.9A. 1309W. duration 1h. 43min ; Output Condition : NTC200 dis.. 40.8Vdc. 28.9 A

- -

Con100 housing 87.2 87.5 89.2 91.2 - - C100 84.2 90.5 86.3 90.6 - - L100 winding 83.6 115.8 104.4 93.8 - - C101 83.1 115.0 94.5 90.1 - - L101 83.6 130.5 108.2 94.4 - - F100 83.2 121.0 108.4 90.3 - - T202 core 85.6 81.5 80.2 83.2 - - C102 83.1 110.7 91.8 86.3 - - L102 86.0 142.3 116.2 97.1 - - PWB near CON100 82.9 92.0 91.8 91.1 - - PWB near DB100 83.6 108.0 102.9 95.2 - - C200 top 82.9 93.2 81.2 85.1 - - C113 top 80.4 79.6 73.7 81.5 - - L200 core 109.9 101.5 90.8 92.2 - - L200 coil 127.6 112.3 106.9 107.3 - - T202 coil 81.1 77.7 78.1 80.4 - 150 T200 coil 101.6 124.6 122.4 97.5 - 190 T200 core 93.0 132.0 113.6 97.1 - 190 T201 coil 103.7 140.7 122.4 107.7 - 190

Page 127: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 40 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

T201 core 98.2 131.7 115.8 101.6 - 190 PWB near D207 108.6 119.8 118.5 107.8 - - C213 top 92.4 107.8 93.3 94.0 - - T100 core/coil 91.8 85.3 89.9 86.1 - - L202 winding 100.1 116.4 111.2 101.0 - - PWB near L202 98.0 116.6 109.6 100.1 - - CON100 housing SELV 99.9 93.0 101.6 100.3 - - Heat sink left 101.6 102.7 115.1 103.3 - - Heat sink right 84.2 97.4 102.0 94.8 - - Front bezel 75.9 57.2 74.3 76.5 - - T101 core/coil 85.8 80.6 87.3 82.6 - - Metal chassis top 84.3 82.7 91.3 83.3 - - Ambient 75.1 44.9 72.3 75.4 - - - Input

Condition : 190 V. 50 Hz. 10.5A. 1990W. duration 1h. 43min ; Output Condition : NTC100 dis. on main PCB. 50.1Vdc. 35.2A

Input Condition : 187 V. 50 Hz. 7.1A. 1318W. duration 1h. 41min ; Output Condition : NTC100 dis. on internal PCB. 40.8Vdc. 29.1A

- - - -

Con100 housing 100.7 91.8 - - - - C100 101.3 91.2 - - - - L100 winding 110.3 94.5 - - - - C101 104.1 90.7 - - - - L101 112.1 95.1 - - - - F100 105.4 90.5 - - - - T202 core 86.3 83.3 - - - - C102 97.7 86.9 - - - -

Page 128: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 41 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

L102 118.6 97.8 - - - - PWB near CON100 101.2 91.6 - - - - PWB near DB100 105.8 95.6 - - - - C200 top 92.6 84.9 - - - - C113 top 85.6 81.4 - - - - L200 core 100.4 92.9 - - - - L200 coil 113.6 108.6 - - - - T202 coil 83.1 80.6 - - - 150 T200 coil 114.2 98.3 - - - 190 T200 core 114.8 99.8 - - - 190 T201 coil 125.3 107.7 - - - 190 T201 core 116.4 103.0 - - - 190 PWB near D207 118.3 111.8 - - - - C213 top 103.2 94.6 - - - - T100 core/coil 89.2 86.2 - - - - L202 winding 111.8 102.3 - - - - PWB near L202 110.7 101.5 - - - - CON100 housing SELV 108.0 102.0 - - - - Heat sink left 116.6 112.7 - - - - Heat sink right 103.0 94.8 - - - - Front bezel 76.9 76.6 - - - - T101 core/coil 85.9 82.9 - - - - Metal chassis top 90.5 82.3 - - - - Ambient 75.7 75.5 - - - - Flatpack2 24V - - - - - - Input

Condition : 85 V, 50 Hz, 9.4A, duration 1 h, 29min ; Output Condition : 24.2 Vdc, 27.6 A

Input Condition : 100 V, 50 Hz, 10.4A, duration 2 h, 10min ; Output Condition : 24.2Vdc, 36.9 A

Input Condition : 176 V, 50 Hz, 13.4A, duration 3 h, 44min ; Output Condition : 24.2 Vdc, 83.3 A

Input Condition : 230 V, 50 Hz, 10.0A, duration 14 h, 17min ; Output Condition : 24.2 Vdc, 82.4 A

Input Condition : 250 V, 50 Hz, 9.1A, duration 1h 14min ;Output Condition : 24.2 Vdc, 82.4 A

Con100 housing 58.2 59.9 74.1 69.7 67.3 - C100 62.5 64.9 78.6 70.4 67.0 105

Page 129: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 42 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

L100 winding 67.1 70.5 87.3 75.5 71.4 155 C101 63.2 65.6 79.2 70.6 67.0 105 L101 66.2 69.5 85.8 73.9 69.5 155 F100 62.7 65.3 78.8 70.1 66.3 - C102 59.7 61.0 70.8 66.0 63.2 105 L102 67.6 71.6 91.3 76.5 71.5 155 PWB near CON100 58.0 59.7 72.7 67.9 65.5 130 PWB near DB100 71.3 74.4 90.9 81.0 76.8 130 C200 top 54.5 55.2 63.2 61.8 60.0 105 C113 top 53.2 53.5 58.9 58.5 56.8 105 L200 core 53.6 54.3 61.6 62.0 60.3 155 L200 coil 52.4 53.5 58.0 58.2 56.9 155 T202 coil 53.4 54.2 56.4 55.4 54.0 90 T200 coil 60.3 63.0 97.1 95.5 93.0 130 T200 core 63.6 66.1 98.6 98.1 96.6 130 T201 coil 65.0 69.5 118.4 118.1 116.4 130 T201 core 59.4 61.9 92.2 90.9 89.1 130 PWB near D207 59.9 63.5 100.8 100.2 98.4 130 C213 top 56.4 58.3 81.2 80.4 78.7 105 Ambient1 48.3 50.8 50.6 50.1 49.5 - L202 winding 59.3 63.1 104.5 104.0 102.2 155 PWB near CON100 58.0 60.8 92.9 92.5 90.8 130 CON100 housing SELV 57.6 60.3 91.0 90.9 89.5 - Heat sink near D211 60.1 63.6 90.3 88.6 86.9 - Heat sink near D104 62.9 65.0 79.6 74.1 71.3 - Front bezel 49.8 50.3 51.3 51.7 50.5 95 Ambient2 48.0 50.3 49.7 50.2 49.5 - - Input

Condition : 278 V. 50 Hz. 8.3A. duration 1 h. 31min ; Output Condition : 24.2 Vdc. 82.7 A

Input Condition : 85 V, 50 Hz, 5.9A, duration 1 h, 28min ; Output Condition : 22.2 Vdc, 18.9 A

Input Condition : 176 V, 50 Hz, 6.5A, duration 1 h, 58min ; Output Condition : 17.5 Vdc, 55.7 A

Input Condition : 250 V, 50 Hz, 4.5A, duration 17h 31min ; Output Condition : 17.5 Vdc, 55.7 A

Input Condition : 275 V. 50 Hz. 4.5A. duration 1 h. 59min ; Output Condition : 19.0 Vdc. 56.9 A

-

Page 130: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 43 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Con100 housing 66.6 83.4 89.8 88.0 87.9 - C100 65.4 84.1 88.3 85.9 84.8 105 L100 winding 69.0 85.6 89.9 86.5 85.5 155 C101 65.3 84.1 88.0 85.6 84.7 105 L101 67.2 85.2 89.1 85.9 85.0 155 F100 64.4 84.4 87.9 85.6 84.8 - T202 core 82.0 85.3 85.4 85.5 90 C102 61.9 81.9 85.4 84.3 83.7 105 L102 68.6 86.1 91.2 87.6 86.8 155 PWB near CON100 64.5 82.7 88.9 87.7 87.3 130 PWB near DB100 74.3 87.7 92.8 89.8 89.3 130 C200 top 59.5 80.5 84.7 84.4 84.5 105 C113 top 56.4 78.7 81.3 81.5 81.6 105 L200 core 60.0 79.8 92.6 92.9 92.3 155 L200 coil 56.3 80.4 97.6 97.9 97.3 155 T202 coil 53.5 79.4 81.5 81.9 81.9 90 T200 coil 93.0 85.2 102.8 103.2 103.0 130 T200 core 96.4 85.1 96.9 97.3 97.4 130 T201 coil 116.2 86.9 110.9 111.2 110.9 130 T201 core 88.8 87.5 105.2 105.4 105.5 130 PWB near D207 98.2 84.4 108.8 109.0 108.7 130 C213 top 78.5 81.7 93.5 93.8 93.7 105 Ambient1 49.0 75.3 75.2 75.5 75.8 - L202 winding 102.1 84.5 112.4 112.5 112.4 155 PWB near CON100 90.6 83.1 102.2 102.1 102.1 130 CON100 housing SELV 89.4 82.2 97.3 96.9 97.1 - Heat sink near D211 86.5 85.9 108.2 108.2 108.4 - Heat sink near D104 69.7 87.7 94.3 92.1 91.9 - Front bezel 50.0 75.6 76.0 76.4 76.5 95 Ambient2 49.0 75.6 76.0 76.0 76.3 - - Input

Condition : 176 V. 50 Hz. 0.5A. duration 7h 14min ; Output Condition : S-c. 0.4Vd

Input Condition : 177 V. 50 Hz. 6.5A. duration 19min ; Output Condition : NTC100 on main board removed. Unit damage

- - - -

Page 131: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 44 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

c. 71.1 A

d, start at 25.0Vdc. 79.6 A Max. temp. measured

Con100 housing 87.9 85.0 - - - - C100 84.1 92.9 - - - - L100 winding 83.8 95.5 - - - - C101 83.4 90.8 - - - - L101 83.1 97.4 - - - - F100 83.0 104.7 - - - - T202 core 84.9 - - - - 150 C102 83.1 90.1 - - - - L102 84.9 103.9 - - - - PWB near CON100 87.7 87.8 - - - - PWB near DB100 85.4 105.5 - - - - C200 top 84.8 84.3 - - - - C113 top 82.0 81.6 - - - - L200 core 98.6 88.9 - - - - L200 coil 104.2 93.2 - - - - T202 coil 81.9 83.1 - - - 150 T200 coil 106.5 112.6 - - - 190 T200 core 98.7 95.0 - - - 190 T201 coil 116.3 120.2 - - - 190 T201 core 108.2 95.0 - - - 190 PWB near D207 115.3 108.7 - - - - C213 top 96.2 89.9 - - - - Ambient1 76.5 73.4 - - - - L202 winding 127.1 106.8 - - - - PWB near CON100 111.0 102.3 - - - - CON100 housing SELV 103.4 104.7 - - - - Heat sink near D211 114.1 106.6 - - - - Heat sink near D104 86.5 100.5 - - - - Front bezel 76.8 74.1 - - - - Ambient2 76.2 73.5 - - - - - Input

Condition : 180 V. 50 Hz. 5.6A. duration

Input Condition : 177 V. 50 Hz. 8.4A. duration 2h. 1min ;

Input Condition : 176 V. 50 Hz. 12.5A. duration 1h. 58min ;

Input Condition : 250 V. 50 Hz. 10.3A. duration 1h. 39min ;

- -

Page 132: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 45 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

36min ; Output Condition : Blocked ventilation. Unit shut down, start at 26.5 Vdc. 75.1 A

Output Condition : NTC200 dis. on main PCB. 20.3Vdc. 62.6A

Output Condition : NTC100 dis. on internal PCB. 25.0Vdc. 77.6A

Output Condition : Transformer overload. Unit damaged 25.2Vdc. 77.7A. Additional load increased from 0 - 46.8A

T202 core 90.3 83.8 84.2 - - 150 L200 coil 99.7 95.9 98.4 - - - T200 coil 122.2 109.2 112.6 118.1 - 190 T200 core 111.8 98.2 101.4 110.6 - 190 T201 coil 131.0 120.5 124.5 145.0 - 190 T201 core 114.3 105.1 108.5 122.9 - 190 L202 winding 111.5 99.9 103.2 - - - Ambient 75.1 75.0 75.0 24.9 - - temperature T of winding: R1 (Ω) R2 ( Ω) T (°C) allowed

Tmax (°C)insulation

class

supplementary information:

5.2 TABLE: electric strength tests, impulse tests and voltage surge tests Pass

test voltage applied between: test voltage (V) a.c./d.c.

breakdown Yes / No

Flatpack2 1800W 48V - - Primary -SELV 4243 Vdc No Primary - Earth 2121 Vdc No T200/T201: One layer of insulation 4243 Vdc No BobbinT202: 4243 Vdc No Insulation between components and heat sink 2121 Vdc No Insulation between chassis and PWB 2121 Vdc No Flatpack2 2000W 48V - - Primary -SELV 4250 Vdc No Primary - Earth 2400 Vdc No

Page 133: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 46 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

T200/T201: One layer of insulation 4250 Vdc No BobbinT202: 4250 Vdc No Insulation between components and heat sink 2400 Vdc No Insulation between chassis and PWB 2400 Vdc No Flatpack2 24V - - Primary -SELV 4250 Vdc No Primary - Earth 2650 Vdc No T200/T201: One layer of insulation 4250 Vdc No BobbinT202: 4250 Vdc No Insulation between components and heat sink 2650 Vdc No Insulation between chassis and PWB 2650 Vdc No All models - - Insulation Formex GK-5BK 5000 Vdc* No Insulation Formex GK-10 5000 Vdc* No Insulation Formex GK-17 5000 Vdc* No supplementary information: There were no indications of break down. *) Formex insulation is used as an alternative insulation between PWB and chassis in Flatpack2 power supplies, but was tested also to comply with Reinforced insulation.

5.3 TABLE: fault condition tests Pass ambient temperature (°C) ....................................... : See below — model/type of power supply.................................... : See below — manufacturer of power supply ................................ : Eltek Energy A/S — rated markings of power supply ............................. : 1) Flatpack2 1800 W 48V:

Input: 230 Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2) Flatpack2 2000 W 48V: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A 3) Flatpack2 24 V: Input: 100 - 250Vac, 45-66 Hz, 13.5 Amax Output 26.7 Vdc, 75 A

Page 134: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 47 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

component No.

fault test voltage (V)

test time fuse No.

fuse current (A)

result

Flatpack2 1800W 48V

- - - - - -

PSU Blocked ventilations

- - F100, F101

- See heating test results for details. No hazard.

NTC 200 NTC 200 (SC) - - F100, F101

- See heating test results for details. No hazard.

NTC 100 on internal PWB

NTC 100 (SC) - - F100, F101

- See heating test results for details. No hazard.

NTC 100 on main PWB

NTC 100 (SC) - - F100, F101

- See heating test results for details. No hazard.

T200-T201 OL 189 10 min. F100, F101

12.13 The output was loaded with rated load (48 Vdc, 25.6 A), an external load was added right after the rectifying diode (D206)(Additional load: 5.89 A, 287 W) Unite operated for 10 min. then Switch transistors Q200 and Q201 broke (SC), F100 and F101 then operates. Maximum temperature measured on the transformer T201 (windings) was 95 °C No Hazard

T202 OL 232 - F100, F101

- An external load was added right after the rectifying diode (D204). The load was increased in small step to 0.61 A max. The maximum temperature measured on the core 41.0 °C If the external load was increased above 0.65 A, the transformer breaks. Ambient: 28.2 °C

Page 135: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 48 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

18.5 %RH (Test performed 3 times total)

Fan (Sanyo Denki)

Locked rotor 12 V 7 hrs. - - The Fan was operating with its rotor locked for 7 hours. Maximum temperature measured on the housing was 75.2 °C

Fan (Sunon)

Locked rotor 12 V 7 hrs. - - The Fan was operating with its rotor locked for 7 hours. Maximum temperature measured on the housing was 39.1 °C

L201 SC 229.6 V - F100, F101

0.199 The output voltage increased to 54.04 Vdc No Hazard

D206 SC 229.7 - F100, F101

3.2 Output voltage drops to 5 Vdc. D201 blows.

D207 SC 229.6 - F100, F101

3.2 Output voltage drops to 5 Vdc. D201 blows.

Q200 Pin1 - Pin2 (SC) 230 1 sec F100, F101

- The unit broke No Hazard

C110 SC 230 1 sec F100, F101

- The unit powers down No hazard

DB100 Pin1 - Pin2 (SC) 230 1 sec. F100, F101

- Primary fuses F100 and F101 operated No hazrad

D202 Pin1 - Pin2 (SC) 230 1 sec F100, F101

- The unit powers down. No hazard

Q103 Pin1 - Pin2 (SC) 230 1 sec F100, F101

- Primary fuses F100 and F101 operated No hazard

C116 SC 230 1hour 15 mins

F100, F101

- The unit thermal down. Maximum temperature measured on T202 (core) was 81.5 °C

Flatpack2 2000W 48V

- - - - - -

PSU Blocked 250V - F100 - See heating test results for

Page 136: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 49 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

ventilation , F101

details. Power supply shuts down output at 75°C ambient, due to high internal temperature. At ambient temperature at 45°C max. temperature is 140.7°C on T201. No hazard

NTC200 S-c 250V - F100, F101

- See heating test results for details. No hazard

NTC100 on internal PWB

S-c 250V - F100, F101

- See heating test results for details. No hazard

NTC100 on main PWB

S-c 250V - F100, F101

- See heating test results for details. No hazard

Flatpack2 24V

- - - - - -

ISO 200 S-c pin1-2 250V 10min F100, F101

9.3A – 0.3A Output shutdown. No hazard. Normal operation after fault is removed.

ISO 200 S-c pin3-4 250V 5min F100, F101

9.3A – 0.3A Output shutdown. No hazard. Power supply does not start after fault is removed.

ISO 201 S-c pin3-4 250V 10min F100, F101

9.2A – 0.3A Output shutdown. No hazard. Power supply does not start after fault is removed.

ISO 202 S-c pin1-2 250V 10min F100, F101

9.3A – 3.1A Output reduced to 14V, 45A. No hazard. Normal operation after fault is removed.

D206 S-c pin1-2 240V 1 sec. F100/F101

>>15A Output shutdown immediately. Both fuses broke with several other components. No hazards.

PSU Blocked ventilation

250V 36 min F100, F101

8.4 - 0 See heating test results for details. Power supply tested at 75°C ambient. Maximum temperature is 131°C on T201, before output shuts down. When PSU has cooled it starts again. No hazard

NTC200 dis 250V 2h 1min F100,

8.4 See heating test results for details. Temperature

Page 137: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 50 of 50 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

F101 stabilized. No hazard NTC100 on internal PWB

dis 250V 1h 58min F100, F101

12.5 See heating test results for details. Temperatures stabilized. Max. temp on T201 is 128°C. No hazard

NTC100 on main PWB

S-c 250V 19min F100, F101

8.8 - 0 See heating test results for details. Maximum temperature measured is 120C, measured on T202, before both fuses and the two switch transistors blows. No hazard

T202 Transformer overload

250V 1h 39min F100, F101

10,3 – 0 Output loaded to 25.2V, 77.5A and extra load added after rectifier diode on secondary side, increased slowly. After 10min. the power supply started to derate, due to high internal temperature. The extra load was increased from 0A to 46.8A. Maximum temperature on T201 was measured to be 145°C, before the power supply unit was damaged. Both F100 and F101 blow together with some other components and 1h and 15 min. No hazard.

Fan (Sanyo Denki)

Locked rotor 12 V 20h 47min. - - The Fan was operating with its rotor locked. Maximum temperature measured on the housing was 41.3 °C

Fan (Sunon)

Locked rotor 12 V 20h 47min. - - The Fan was operating with its rotor locked. Maximum temperature measured on the housing was 101.4 °C

supplementary information:

Page 138: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 5 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Enclosure Photographs

Supplement Id Description 3-01 Overall Front View 3-02 Overall Rear View 3-03 Overall Front View with top cover removed (Flatpack 1800W 48V) 3-04 Internal View (Flatpack 1800W 48V) 3-05 Internal View (Flatpack 1800W 48V) 3-06 Internal View, from the rear side (Flatpack 1800W 48V) 3-07 Bottom View - Bottom cover removed (Flatpack 1800W 48V) 3-08 Bottom View - Main Earth Trace (Flatpack 1800W 48V) 3-09 Overall Front View with top cover removed Flatpack (Flatpack 2000W 48V) 3-10 Internal view of capacitors (Flatpack 2000W 48V) 3-11 Internal view of fuses (Flatpack 2000W 48V) 3-12 Bottom View - Bottom cover removed (Flatpack 2000W 48V) 3-13 Bottom View - Main Earth Trace (Flatpack 2000W 48V) 3-14 Internal View (Flatpack2 24V) 3-15 Bottom View (Flatpack2 24V) 3-16 Bottom Cover (Flatpack2 24V) 3-17 Earth Trace (Flatpack2 24V)

Page 139: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 5 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Photographs ID 3-14

Page 140: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 5 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Photographs ID 3-15

Page 141: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 5 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Photographs ID 3-16

Page 142: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 5 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Photographs ID 3-17

Page 143: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Enclosure Diagrams

Supplement Id Description 4-01 Main transformer T200/T201 4-02 Input choke L100/L101 4-03 Inductor L102 4-04 Inductor L200 4-05 Transformer T100/T101 4-06 Transformer T202 4-07 DC Common mode Choke L202 4-08 Top Cover, Bottom Cover and left/right Heat Sink 4-09 Inductor L103 (2000W version) 4-10 Transformer T100/T101 4-11 Inductor L200 (Flatpack2 2000 W 48V and Flatpack2 24V) 4-12 Main transformer T200/T201 (Flatpack2 24V) 4-13 Input Choke L100/L101 (Flatpack2 24V)

Page 144: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 145: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 146: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 147: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 148: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 149: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 7 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-12

Page 150: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 8 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-12

Page 151: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 9 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-12

Page 152: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 10 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-12

Page 153: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 11 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-12

Page 154: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 12 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-13

Page 155: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 13 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-13

Page 156: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 14 of 14 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Diagrams ID 4-13

Page 157: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 6 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Enclosure Schematics + PWB

Supplement Id Description 5-01 Component layout 5-02 Trace layout 5-04 Component layout (Flatpack2 1800W 48V and Flaptack2 2000W 48V) 5-05 Tracelayout (Flatpack2 1800W and Flatpack2 2000W 48V) 5-06 Trace layout 24 V 5-07 Component layout 24 V

Page 158: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 6 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Schematics ID 5-06

Page 159: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 6 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Schematics ID 5-06

Page 160: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 6 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Schematics ID 5-06

Page 161: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 6 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Schematics ID 5-06

Page 162: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 6 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Schematics ID 5-07

Page 163: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 2 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Enclosure Miscellaneous

Supplement Id Description 7-01 Representative Label for 1800W model 7-02 Representative Label for 2000W model 7-03 Representive Label for 24 V 2000W model

Page 164: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 2 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Misc ID 7-03

Page 165: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 2 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Enclosure Test Record

Description Test Record 1 Protective Earthing Trace Earth fault current test Test Record 2

Page 166: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 2 Report Reference # E177343-A19-UL-2Amendment 1 2006-05-11

Underwriters Laboratories Inc.

Test Record No. 2

Testing of Flatpack2 24V was not considered necessary based upon previous evaluation under CB Scheme. The CB Scheme Test Certificate ref. no. DK-9630/A1 and Report Ref. No. E177343-A19-CB amendment 1, dated 2006-05-11 and 2006-05-09 respectively were prepared by Rolf Bårnes Eltek Energy A/S and Jan J. Jensen.UL International Demko A/S. The following tests were conducted: Test Comments Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard.

Page 167: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 2 Report Reference # E177343-A19-UL-2

Copyright © 2006 Underwriters Laboratories Inc.

COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical

Business Equipment Product Category CCN: QQGQ2, QQGQ8 Test Procedure: Component Recognition Product: Power Supply for building-in Model/Type Reference: Flatpack2 A B C

Where A can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank B can be 48V or blank C can be any alphanumeric letters or blank for marketing purposes only.

Rating(s): 1800W Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2000W: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A

Standards: UL 60950-1:2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003

Applicant Name and Address:

ELTEK ENERGY A/S GRAATERUDVEIEN 8 3036 DRAMMEN NORWAY

This Report includes the following parts, in addition to this cover page:

1. Specific Inspection Criteria 2. Specific Technical Criteria 3. Clause Verdicts 4. Critical Components 5. Test Results 6. National Differences 7. Enclosures

Page 168: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 2 Report Reference # E177343-A19-UL-2

Copyright © 2006 Underwriters Laboratories Inc.

This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. Test Report By: Reviewed By:

Casper S. Larsen Jan J. Jensen Associate Project Engineer Project Engineer UL International Demko A/S UL International Demko A/S

Page 169: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 69 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

SPECIFIC INSPECTION CRITERIA BA1.0 Special Instructions to UL Representative BA1.1 Special test has been performed on the printing wirring board´s protective earthing trace. As a

production line test, an Earthing Test shall be conducted on 100% of production units between the ground pin and accessible dead metal parts. The test shall show that the resistance will not be greater than 0.006 Ohm between input GND connector and Ground. Test shall be carried out as follows:For samples with an appliance inlet only, the test circuit was connected between the grounding lead of the 1.82 m (6 ft) power supply cord and the grounding lead of the printed wiring board taking into account the minimum cross-sectional area of the ground trace. If a grounding lead was not provided, a suitable length of minimum No. 16 AWG wire was used. The test circuit was capable of delivering 2000 A at 48V dc and having a power factor of 75-80 percent through shorted bus bars with a 30 A service entrance type circuit breaker (CB) in series at the testing terminals. The circuit breaker was connected to the bus bar by 1.22 m (4 ft) of No. 12 AWG wire. The test is continued for 5 seconds unless ultimate results occur; e.g. circuit breaker trips, fuse opens, trace opens, etc.

BB1.0 Supporting Documentation BB1.1 The following documents located at the beginning of this Procedure supplement the requirements

of this Test Report:

A. Authorization - The Authorization page may include additional Factory Identification Code markings.

B. Generic Inspection Instructions -

i. Part AC details important information which may be applicable to products covered by this

Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report.

ii. Part AE details any requirements which may be applicable to all products covered by this

Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report.

iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the

technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

BC1.0 Markings and instructions BC1.1 The following markings and instructions are provided as indicated. BC1.2 All clause references are from UL 60950-1:2003, First Edition. Standard Clause

Clause Title Marking or Instruction Details

Other 1.7.1 Power rating - Ratings

Ratings (voltage, frequency/dc, current)

1.7.1 Power rating - Model

Model Number

Page 170: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 69 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

1.7.1 Power rating - Company identification

Listee's or Recognized company's name, Trade Name, Trademark or File

1.7.6 Fuses - Non-operator access/soldered-in fuses

Unambiguous reference to service documentation for instructions for replacement of fuses replaceable only by service personnel

BD1.0 Production-Line Testing Requirements BD1.1 Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for

further information.

Test

Potential

Model Component Removable Parts Test probe location V

rms V dcTest

Time, s

N/A BD1.2 Earthing Continuity Test Exemptions - This

test is not required for the following models:

BD1.3 Electric Strength Test Exemptions - This test is not required for the following models:

BD1.4 Electric Strength Test Component Exemptions - The following solid-state components may disconnected from the remainder of the circuitry during the performance of this test:

BE1.0 Sample and Test Specifics for Follow-Up Tests at UL

BE1.1 Model Component Material Test Sample(s) Test

Specifics

N/A

Page 171: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 69 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

SPECIFIC TECHNICAL CRITERIA

UL 60950-1, First Edition Information technology equipment - Safety-

Part 1: General Requirements

Report Reference No........................: E177343-A19-UL-2 Compiled by .....................................: Casper S. Larsen Reviewed by ....................................: Jan J. Jensen Date of issue ....................................: 2006-03-13 Standards .........................................: UL 60950-1:2003, First Edition

CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 Test procedure .................................: Component Recognition Non-standard test method ...............: N/A Test item description .......................: Power Supply for building-in Trademark ........................................: Model and/or type reference ............: Flatpack2 A B C

Where A can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank B can be 48V or blank C can be any alphanumeric letters or blank for marketing purposes only.

Rating(s) ...........................................: 1800W Input: 100 - 250Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2000W: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A

Page 172: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 69 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Particulars: test item vs. test requirements Equipment mobility .................................................... : for building-in Operating condition ................................................... : continuous Mains supply tolerance (%) ....................................... : +10%, -15% (according to manufacturer specification)Tested for IT power systems ..................................... : Yes IT testing, phase-phase voltage (V) .......................... : 230 Vac Class of equipment ................................................... : Class I (earthed) Mass of equipment (kg) ............................................ : 1.80 kg Protection against ingress of water ........................... : IP X0

Possible test case verdicts: - test case does not apply to the test object ............. : N / A - test object does meet the requirement ................... : Pass - test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent

national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

Page 173: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 69 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

GENERAL PRODUCT INFORMATION: CA1.0 Report Summary CA1.1 N/A

CB1.0 Product Description CB1.1 The equipment under test is a switch mode power supply, intended to be used in a rack system.

The power supply converts 230 Vac to 48 Vdc (nominal) and communicates with a controller through its own microprocessor. The unit (in a rack system) is typically used to supply other telecommunication equipment, like mobile phone exchanges etc.

CC1.0 Model Differences CC1.1 The 1800 W version uses main board 101148 and the 2000 W version uses the main board

206425. The two main boards are identical except for minor changes to the layout and component configuration.

CD1.0 Additional Information CD1.1 See cover page for production sites.

The product was investigated to the following additional standards: EN 60950-1:2001 (which includes all European national differences, including those specified in this test report). 2000 W version: Max VA measurements. V=56.7 Vdc, A=41.2, VA=2016 (measured at 53.06 V, 38.0 A)

CE1.0 Technical Considerations CE1.2 The product was submitted and tested for use at the maximum ambient temperature (Tma)

permitted by the manufacturer’s specification of: 75 °C CE1.3 The means of connection to the mains supply is: through a connector on the backplane CE1.4 The product is intended for use on the following power systems: IT, TN CE1.5 The equipment disconnect device is considered to be: For building-in, must be determined in the

end product. CE1.7 The product was investigated to the following additional standards: EN 60950-1:2001 (which

includes all European national differences, including those specified in this test report). CE1.12 The following were investigated as part of the protective earthing/bonding: Printed wiring board

trace (refer to Enclosure - Pictures + Schematics + PWB for layouts) CE1.14 The following are available from the Applicant upon request: Specific data sheets for LEDs that

are used for indicating purposes and assumed to be inherently Class 1 operating in the 400 - 700 nm wavelength range., Installation (Safety) Instructions / Manual

Page 174: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 69 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

CF1.0 Engineering Conditions of Acceptability CF1.1 For use only in or with complete equipment where the acceptability of the combination is

determined by Underwriters Laboratories Inc. When installed in an end-product, consideration must be given to the following:

CF2.0 The end-product Electric Strength Test is to be based upon a maximum working voltage of: 224 Vrms, 488 Vpk on 1800W module and 294Vrms, 568Vp for 2000W module.

CF2.1 The following secondary output circuits are SELV: 48 V output CF2.2 The following secondary output circuits are at hazardous energy levels: 48 Vdc output CF2.3 The power supply terminals and/or connectors are: Suitable for factory wiring only CF2.4 The maximum investigated branch circuit rating is: 20 A CF2.5 The investigated Pollution Degree is: 2 CF2.6 The front bezel complies with the requirements for: 5V ratings CF2.7 Proper bonding to the end-product main protective earthing termination is: Required CF2.8 An investigation of the bonding terminals as protective earthing terminals has: Been conducted CF2.9 The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2

insulation system with the indicated rating greater than Class A (105°C): T200 and T201 (Class F).

CF3 The following end-product enclosures are required: Electrical, Fire

Page 175: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 7 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1 GENERAL Pass 1.5 Components Pass 1.5.1 General Pass

Comply with IEC 60950 or relevant component standard

(see appended table 1.5.1) Pass

1.5.2 Evaluation and testing of components (see appended table 1.5.1) Pass 1.5.3 Thermal controls N/A 1.5.4 Transformers (See annex C) Pass 1.5.5 Interconnecting cables N/A 1.5.6 Capacitors in primary circuits ................................ : Line-to-line capacitors are

subclass X1 or X2.Primary-to-earth capacitors are subclass Y1 or Y2.

Pass

1.5.7 Double insulation or reinforced insulation bridged by components

No bridging components. N/A

1.5.7.1 General N/A 1.5.7.2 Bridging capacitors N/A 1.5.7.3 Bridging resistors N/A 1.5.7.4 Accessible parts N/A 1.5.8 Components in equipment for IT power systems N/A

1.6 Power interface Pass 1.6.1 AC power distribution systems Pass 1.6.2 Input current (see appended table 1.6.2) Pass 1.6.3 Voltage limit of hand-held equipment N/A 1.6.4 Neutral conductor Pass

Page 176: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 8 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.7 Marking and instructions Pass 1.7.1 Power rating Pass

Rated voltage(s) or voltage range(s) (V) ............... : 100 - 250 Vac Pass

Symbol for nature of supply, for d.c. only .............. : N/A

Rated frequency or rated frequency range (Hz).... : 45-66 Hz Pass

Rated current (mA or A) ........................................ : 11.0 Amax for 1800W and 12.5 Amax for 2000W

Pass

Manufacturer's name or trademark or identification mark....................................................................... :

Eltek Pass

Type/model or type reference ............................... : Flatpack2 A B C where A can be 1800, 1800W, 2000, 2000W, 2K, 2kW or blank. B can be 48V or blank. C can be any alphanumeric letters or blank.

Pass

Symbol for Class II equipment only....................... : N/A

Other symbols ....................................................... : N/A

Certification marks................................................. : UL Recognition Mark Pass 1.7.2 Safety instructions N/A 1.7.3 Short duty cycles N/A 1.7.4 Supply voltage adjustment .................................... : N/A 1.7.5 Power outlets on the equipment............................ : N/A 1.7.6 Fuse identification.................................................. : Fuses provided with an

unambiguous cross-reference to service documentation.

Pass

1.7.7 Wiring terminals N/A 1.7.7.1 Protective earthing and bonding terminals ............ : N/A 1.7.7.2 Terminal for a.c. mains supply conductors N/A 1.7.7.3 Terminals for d.c. mains supply conductors N/A 1.7.8 Controls and indicators N/A 1.7.8.1 Identification, location and marking ....................... : N/A 1.7.8.2 Colours .................................................................. : A green LED is illuminated Pass

Page 177: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 9 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

when the unit is operating. A red LED is illuminated when the A yellow LED is illuminated when the

1.7.8.3 Symbols according to IEC 60417 .......................... : There are no switches in the equipment.

N/A

1.7.8.4 Markings using figures........................................... : Figures are not used for indicating different positions of controls.

N/A

1.7.9 Isolation of multiple power sources ....................... : There is only one connection to hazardous voltages.

N/A

1.7.10 IT power distribution systems Pass 1.7.11 Thermostats and other regulating devices N/A 1.7.12 Language............................................................... : Reviewed only English

markings/instructions. -

1.7.13 Durability Pass 1.7.14 Removable parts Pass 1.7.15 Replaceable batteries N/A

Language............................................................... : - 1.7.16 Operator access with a tool ................................... : No operator access areas

require the use of a tool. N/A

1.7.17 Equipment for restricted access locations............. : N/A

Page 178: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 10 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

2 PROTECTION FROM HAZARDS Pass 2.1 Protection from electric shock and energy hazards Pass 2.1.1 Protection in operator access areas Only the front bezel is

considered operator access area.

Pass

2.1.1.1 Access to energized parts Only the front bezel is considered operator access area.

Pass

Test by inspection.................................................. : No access to energized parts. Pass

Test with test finger................................................ : The test finger was unable to contact bare hazardous parts, basic insulation, or ELV circuits.

Pass

Test with test pin.................................................... : The test pin was unable to contact bare hazardous parts.

Pass

Test with test probe ............................................... : No TNV present. N/A 2.1.1.2 Battery compartments............................................ : N/A 2.1.1.3 Access to ELV wiring No operator access to

energized parts. N/A

Working voltage (V); minimum distance (mm) through insulation .................................................. :

-

2.1.1.4 Access to hazardous voltage circuit wiring No operator access to energized parts.

N/A

2.1.1.5 Energy hazards...................................................... : The output of the power supply presents an energy hazard. No operator access permitted.

Pass

2.1.1.6 Manual controls Pass 2.1.1.7 Discharge of capacitors in equipment Pass

Time-constant (s); measured voltage (V) .............. : 0 V after 1 sec. - 2.1.2 Protection in service access areas N/A 2.1.3 Protection in restricted access locations N/A

Page 179: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 11 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

2.2 SELV circuits Pass 2.2.1 General requirements Pass 2.2.2 Voltages under normal conditions (V) ................... : All accessible voltages are

less than 42.4 Vp or 60 V dc and are classified as SELV.

Pass

2.2.3 Voltages under fault conditions (V)........................ : Under fault conditions voltages never exceed 71V peak and 120Vdc and do not exceed 42.4V peak or 60V dc for more than 0.2 sec.

Pass

2.2.3.1 Separation by double insulation or reinforced insulation (method 1)

Pass

2.2.3.2 Separation by earthed screen (method 2) N/A 2.2.3.3 Protection by earthing of the SELV circuit (method

3) N/A

2.2.4 Connection of SELV circuits to other circuits......... : SELV circuits are only connected to other secondary circuits. SELV circuit and all interconnected circuits separated from primary by reinforced insulation. The SELV circuit does not exceed the SELV limits under normal and fault conditions.

Pass

2.3 TNV circuits N/A 2.3.1 Limits N/A

Type of TNV circuits .............................................. : - 2.3.2 Separation from other circuits and from accessible

parts N/A

Insulation employed............................................... : - 2.3.3 Separation from hazardous voltages N/A

Insulation employed............................................... : - 2.3.4 Connection of TNV circuits to other circuits N/A

Insulation employed............................................... : - 2.3.5 Test for operating voltages generated externally N/A

Page 180: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 12 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

2.4 Limited current circuits N/A 2.4.1 General requirements N/A 2.4.2 Limit values N/A

Frequency (Hz) ...................................................... : -

Measured current (mA).......................................... : -

Measured voltage (V) ............................................ : -

Measured capacitance (mF).................................. : - 2.4.3 Connection of limited current circuits to other

circuits N/A

2.5 Limited power sources N/A Inherently limited output N/A

Impedance limited output N/A

Overcurrent protective device limited output N/A

Regulating network limited output under normal operating and single fault condition

N/A

Regulating network limited output under normal operating conditions and overcurrent protective device limited output under single fault condition

N/A

Output voltage (V), output current (A), apparent power (VA):............................................................ :

-

Current rating of overcurrent protective device (A) : -

Page 181: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 13 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

2.6 Provisions for earthing and bonding Pass 2.6.1 Protective earthing Pass 2.6.2 Functional earthing N/A 2.6.3 Protective earthing and protective bonding

conductors Pass

2.6.3.1 General Pass 2.6.3.2 Size of protective earthing conductors N/A

Rated current (A), cross-sectional area (mm2), AWG ...................................................................... :

-

2.6.3.3 Size of protective bonding conductors N/A

Rated current (A), cross-sectional area (mm2), AWG ...................................................................... :

-

2.6.3.4 Resistance (Ohm) of earthing conductors and their terminations, test current (A) ................................. :

Inlet to chassis: 50 A for 4 min. 1800 W version:U= 0.7 V, R=14 mOhm 2000 W version: U=0.13V, R=2.6 mOhm

Pass

2.6.3.5 Colour of insulation ................................................ : N/A 2.6.4 Terminals Pass 2.6.4.1 General Pass 2.6.4.2 Protective earthing and bonding terminals Equipment is provided with an

appliance connector. Pass

Rated current (A), type and nominal thread diameter (mm) ....................................................... :

Connector is rated 35 A -

2.6.4.3 Separation of the protective earthing conductor from protective bonding conductors

The appliance connector is soldered directly on the PWB.

N/A

2.6.5 Integrity of protective earthing Pass 2.6.5.1 Interconnection of equipment N/A 2.6.5.2 Components in protective earthing conductors and

protective bonding conductors Pass

2.6.5.3 Disconnection of protective earth Pass 2.6.5.4 Parts that can be removed by an operator Pass 2.6.5.5 Parts removed during servicing Pass 2.6.5.6 Corrosion resistance Pass

Page 182: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 14 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

2.6.5.7 Screws for protective bonding Pass 2.6.5.8 Reliance on telecommunication network or cable

distribution system N/A

2.7 Overcurrent and earth fault protection in primary circuits Pass 2.7.1 Basic requirements Pass

Instructions when protection relies on building installation

N/A

2.7.2 Faults not covered in 5.3 Pass 2.7.3 Short-circuit backup protection Short-circuit back-up

protection is provided by the building installation.

Pass

2.7.4 Number and location of protective devices............ : One protective device in each phase conductor.

Pass

2.7.5 Protection by several devices All protective devices are located together.

Pass

2.7.6 Warning to service personnel ................................ : The following warning will be provided in the service manual: CAUTION DOUBLE POLE/NEUTRAL FUSING.

Pass

Page 183: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 15 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

2.8 Safety interlocks N/A 2.8.1 General principles N/A 2.8.2 Protection requirements N/A 2.8.3 Inadvertent reactivation N/A 2.8.4 Fail-safe operation N/A 2.8.5 Moving parts N/A 2.8.6 Overriding N/A 2.8.7 Switches and relays N/A 2.8.7.1 Contact gaps (mm) ................................................ : N/A 2.8.7.2 Overload test N/A 2.8.7.3 Endurance test N/A 2.8.7.4 Electric strength test N/A 2.8.8 Mechanical actuators N/A

2.9 Electrical insulation Pass 2.9.1 Properties of insulating materials Pass 2.9.2 Humidity conditioning N/A

Humidity (%) .......................................................... : -

Temperature (°C)................................................... : - 2.9.3 Grade of insulation Pass

Page 184: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 16 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

2.10 Clearances, creepage distances and distances through insulation Pass 2.10.1 General Pass 2.10.2 Determination of working voltage Pass 2.10.3 Clearances Pass 2.10.3.1 General Pass 2.10.3.2 Clearances in primary circuit (see appended table 2.10.3

and 2.10.4) Pass

2.10.3.3 Clearances in secondary circuits (see appended table 2.10.3 and 2.10.4)

Pass

2.10.3.4 Measurement of transient voltage levels Pass 2.10.4 Creepage distances (see appended table 2.10.3

and 2.10.4) Pass

CTI tests................................................................. : Category IIIa and IIIb - 2.10.5 Solid insulation Materials having adequate

thickness are provided. (See table 5.2)

Pass

2.10.5.1 Minimum distance through insulation (see appended table 2.10.5) Pass 2.10.5.2 Thin sheet material Pass

Number of layers (pcs) .......................................... : 2 layers used in T200 and T201.

-

Electric strength test .............................................. : (see appended table 5.2) - 2.10.5.3 Printed boards PWB has a minimum thickness

of 0.4 mm Pass

Distance through insulation Minimum 0.4 mm Pass

Electric strength test for thin sheet insulating material .................................................................. :

(see appended table 5.2) -

Number of layers (pcs) .......................................... : 4 layers Pass 2.10.5.4 Wound components The employed UL Recognized

wiring meets the requirements of 2.10.5.4 and Annex U.

Pass

Number of layers (pcs) .......................................... : Two wrapped layers. Pass

Two wires in contact inside wound component; angle between 45° and 90° ................................... :

N/A

2.10.6 Coated printed boards N/A 2.10.6.1 General N/A

Page 185: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 17 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

2.10.6.2 Sample preparation and preliminary inspection N/A 2.10.6.3 Thermal cycling N/A 2.10.6.4 Thermal ageing (°C) .............................................. : N/A 2.10.6.5 Electric strength test .............................................. : - 2.10.6.6 Abrasion resistance test N/A

Electric strength test .............................................. : - 2.10.7 Enclosed and sealed parts .................................... : N/A

Temperature T1=T2 = Tma - Tamb +10K (°C)...... : N/A 2.10.8 Spacings filled by insulating compound................. : Optocouplers are separately

certified and tested according to 2.10.7. No other components filled by insulating compound.

Pass

Electric strength test .............................................. : (see appended table 5.2) - 2.10.9 Component external terminations Pass 2.10.10 Insulation with varying dimensions N/A

3 WIRING, CONNECTIONS AND SUPPLY Pass 3.1 General Pass 3.1.1 Current rating and overcurrent protection Pass 3.1.2 Protection against mechanical damage Pass 3.1.3 Securing of internal wiring Pass 3.1.4 Insulation of conductors Pass 3.1.5 Beads and ceramic insulators N/A 3.1.6 Screws for electrical contact pressure N/A 3.1.7 Insulating materials in electrical connections N/A 3.1.8 Self-tapping and spaced thread screws N/A 3.1.9 Termination of conductors N/A

10 N pull test N/A 3.1.10 Sleeving on wiring N/A

Page 186: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 18 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

3.2 Connection to an a.c. mains supply or a d.c. mains supply Pass 3.2.1 Means of connection Pass 3.2.1.1 Connection to an a.c. mains supply The unit is provided with an

appliance connector Pass

3.2.1.2 Connection to a d.c. mains supply N/A 3.2.2 Multiple supply connections N/A 3.2.3 Permanently connected equipment N/A

Number of conductors, diameter (mm) of cable and conduits.................................................................. :

-

3.2.4 Appliance inlets The unit is for building-in. Connection to mains power is to be determined in the end product.

N/A

3.2.5 Power supply cords N/A 3.2.5.1 AC power supply cords The unit is for building-in N/A Type....................................................................... : -

Rated current (A), cross-sectional area (mm²), AWG ...................................................................... :

-

3.2.5.2 DC power supply cords N/A 3.2.6 Cord anchorages and strain relief N/A

Mass of equipment (kg), pull (N) ........................... : -

Longitudinal displacement (mm)............................ : - 3.2.7 Protection against mechanical damage N/A 3.2.8 Cord guards N/A

D (mm); test mass (g) ............................................ : -

Radius of curvature of cord (mm) .......................... : - 3.2.9 Supply wiring space N/A

Page 187: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 19 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

3.3 Wiring terminals for connection of external conductors Pass 3.3.1 Wiring terminals N/A 3.3.2 Connection of non-detachable power supply cords N/A 3.3.3 Screw terminals N/A 3.3.4 Conductor sizes to be connected N/A

Rated current (A), cord/cable type, cross-sectional area (mm²) ............................................................. :

-

3.3.5 Wiring terminal sizes N/A

Rated current (A), type and nominal thread diameter (mm) ....................................................... :

-

3.3.6 Wiring terminals design N/A 3.3.7 Grouping of wiring terminals N/A 3.3.8 Stranded wire N/A

Page 188: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 20 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

3.4 Disconnection from the mains supply N/A 3.4.1 General requirement The unit is for building-in.

Disconnection from the mains power is to be determined in the end product.

N/A

3.4.2 Disconnect devices The unit is for building-in. Disconnection from the mains power is to be determined in the end product.

N/A

3.4.3 Permanently connected equipment N/A 3.4.4 Parts which remain energized The unit is for building-in.

Disconnection from the mains power is to be determined in the end product.

N/A

3.4.5 Switches in flexible cords The unit is for building-in. Disconnection from the mains power is to be determined in the end product.

N/A

3.4.6 Single-phase equipment and d.c. equipment The unit is for building-in. Disconnection from the mains power is to be determined in the end product.

N/A

3.4.7 Three-phase equipment Single phase equipment. N/A 3.4.8 Switches as disconnect devices The unit is for building-in.

Disconnection from the mains power is to be determined in the end product.

N/A

3.4.9 Plugs as disconnect devices The unit is for building-in. Disconnection from the mains power is to be determined in the end product.

N/A

3.4.10 Interconnected equipment N/A 3.4.11 Multiple power sources N/A

3.5 Interconnection of equipment Pass 3.5.1 General requirements Pass 3.5.2 Types of interconnection circuits ........................... : Interconnection circuits are

SELV CIRCUITS. Pass

3.5.3 ELV circuits as interconnection circuits N/A

Page 189: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 21 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

4 PHYSICAL REQUIREMENTS Pass 4.1 Stability N/A Angle of 10° Equipment is intended for

building-in. N/A

Test: force (N)........................................................ : N/A

4.2 Mechanical strength Pass 4.2.1 General Pass 4.2.2 Steady force test, 10 N Tested on internal

components. No hazard Pass

4.2.3 Steady force test, 30 N No hazard as a result of the 30 N test. Performed on side and rear part of enclosure.

Pass

4.2.4 Steady force test, 250 N Only front bezel is considered operator accessible. No hazards as a result of the 250 N test. Performed on the front bezel of enclosure.

Pass

4.2.5 Impact test Only front bezel is considered operator accessible.

Pass

Fall test N/A

Swing test No access to hazardous parts. Pass 4.2.6 Drop test N/A 4.2.7 Stress relief test N/A 4.2.8 Cathode ray tubes N/A

Picture tube separately certified ............................ : N/A 4.2.9 High pressure lamps N/A 4.2.10 Wall or ceiling mounted equipment; force (N) ....... : N/A

Page 190: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 22 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

4.3 Design and construction Pass 4.3.1 Edges and corners Only front bezel is considered

operator accessible. Pass

4.3.2 Handles and manual controls; force (N) ................ : 72 N applied to handle for 1 min.

Pass

4.3.3 Adjustable controls N/A 4.3.4 Securing of parts No loosening of parts impairing

creepage distances or clearances over supplementary or reinforced insulation is likely to occur.

Pass

4.3.5 Connection of plugs and sockets The equipment does not have any interchangeable plugs/sockets.

Pass

4.3.6 Direct plug-in equipment N/A

Dimensions (mm) of mains plug for direct plug-in . : N/A

Torque and pull test of mains plug for direct plug-in; torque (Nm); pull (N) .............................................. :

N/A

4.3.7 Heating elements in earthed equipment N/A 4.3.8 Batteries N/A 4.3.9 Oil and grease N/A 4.3.10 Dust, powders, liquids and gases N/A 4.3.11 Containers for liquids or gases N/A 4.3.12 Flammable liquids.................................................. : N/A

Quantity of liquid (l)................................................ : N/A

Flash point (°C)...................................................... : N/A 4.3.13 Radiation; type of radiation Pass 4.3.13.1 General N/A 4.3.13.2 Ionizing radiation N/A

Measured radiation (pA/kg) ................................... : -

Measured high-voltage (kV)................................... : -

Measured focus voltage (kV)................................. : -

CRT markings........................................................ : - 4.3.13.3 Effect of ultraviolet (UV) radiation on materials N/A

Page 191: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 23 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Part, property, retention after test, flammability classification .......................................................... :

N/A

4.3.13.4 Human exposure to ultraviolet (UV) radiation........ : N/A 4.3.13.5 Laser (including LEDs) Defuse LED's only. Data Sheet

evaluated. Pass

Laser class............................................................. : - 4.3.13.6 Other types ............................................................ : N/A

4.4 Protection against hazardous moving parts Pass 4.4.1 General Only front bezel is considered

operator accessible. Pass

4.4.2 Protection in operator access areas Pass 4.4.3 Protection in restricted access locations N/A 4.4.4 Protection in service access areas N/A

4.5 Thermal requirements Pass 4.5.1 Maximum temperatures (see appended table 4.5) Pass Normal load condition per Annex L ....................... : Maximum continuous

operation is as defined under General Product Information.

Pass

4.5.2 Resistance to abnormal heat (see appended table 4.5.2) Pass

Page 192: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 24 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

4.6 Openings in enclosures Pass 4.6.1 Top and side openings Openings only provided in the

rear and front side of the unit. Rear side: 18 openings each measuring 14x6.7 mm. Front side: Openings in front of fans, and 3 holes for indicating diodes.

Pass

Dimensions (mm)................................................... : - 4.6.2 Bottoms of fire enclosures Pass

Construction of the bottom..................................... : No openings in the bottom of the unit.

-

4.6.3 Doors or covers in fire enclosures N/A 4.6.4 Openings in transportable equipment N/A 4.6.5 Adhesives for constructional purposes N/A

Conditioning temperature (°C)/time (weeks) ......... : -

Page 193: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 25 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

4.7 Resistance to fire Pass 4.7.1 Reducing the risk of ignition and spread of flame Pass

Method 1, selection and application of components wiring and materials

(see appended table 4.7) Pass

Method 2, application of all of simulated fault condition tests

N/A

4.7.2 Conditions for a fire enclosure Unit is for building-in, a fire enclosure must be provided in the end product.

N/A

4.7.2.1 Parts requiring a fire enclosure Unit is for building-in, a fire enclosure must be provided in the end product.

N/A

4.7.2.2 Parts not requiring a fire enclosure Pass 4.7.3 Materials Pass 4.7.3.1 General Pass 4.7.3.2 Materials for fire enclosures Front bezel is considered a

part of the fire enclosure. The front bezel complies with 5V rating.

Pass

4.7.3.3 Materials for components and other parts outside fire enclosures

Clip on front bezel is tested for HB40.

Pass

4.7.3.4 Materials for components and other parts inside fire enclosures

All internal materials are rated V-2 or better or are mounted on a PWB rated V-1 or better.

Pass

4.7.3.5 Materials for air filter assemblies N/A 4.7.3.6 Materials used in high-voltage components N/A

Page 194: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 26 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS Pass 5.1 Touch current and protective conductor current Pass 5.1.1 General Pass 5.1.2 Equipment under test (EUT) Pass 5.1.3 Test circuit Pass 5.1.4 Application of measuring instrument Pass 5.1.5 Test procedure Pass 5.1.6 Test measurements Pass

Test voltage (V) ..................................................... : 1) 1800 W Version: 230 V 2) 2000 W Version: 250 V

-

Measured touch current (mA)................................ : 1) 2.4 mA maximum 2) 1.9 mA maximum

-

Max. allowed touch current (mA)........................... : 3.5 mA (Class I stationery) -

Measured protective conductor current (mA) ........ : -

Max. allowed protective conductor current (mA) ... : - 5.1.7 Equipment with touch current exceeding 3.5 mA .. : N/A 5.1.8 Touch currents to and from telecommunication

networks and cable distribution systems and from telecommunication networks

N/A

5.1.8.1 Limitation of the touch current to a telecommunication network and a cable distribution system

N/A

Test voltage (V) ..................................................... : -

Measured touch current (mA)................................ : -

Max. allowed touch current (mA)........................... : - 5.1.8.2 Summation of touch currents from

telecommunication networks ................................. : N/A

5.2 Electric strength Pass 5.2.1 General (see appended table 5.2) Pass 5.2.2 Test procedure (see appended table 5.2) Pass

Page 195: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 27 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

5.3 Abnormal operating and fault conditions Pass 5.3.1 Protection against overload and abnormal

operation (See appenden table 5.3) Pass

5.3.2 Motors (see appended Annex B) Pass 5.3.3 Transformers (see appended Annex C) Pass 5.3.4 Functional insulation .............................................. : Method C. Pass 5.3.5 Electromechanical components N/A 5.3.6 Simulation of faults (see appended table 5.3) Pass 5.3.7 Unattended equipment N/A 5.3.8 Compliance criteria for abnormal operating and

fault conditions The maximum temperature of 300°C was not exceeded. No fire, emission of molten metal or deformation was noted during the tests.

Pass

6 CONNECTION TO TELECOMMUNICATION NETWORKS N/A 6.1 Protection of telecommunication network service persons, and users of other

equipment connected to the network, from hazards in the equipment N/A

6.1.1 Protection from hazardous voltages N/A 6.1.2 Separation of the telecommunication network from earth N/A 6.1.2.1 Requirements N/A

Test voltage (V) ..................................................... : -

Current in the test circuit (mA)............................... : - 6.1.2.2 Exclusions.............................................................. : N/A

6.2 Protection of equipment users from overvoltages on telecommunication networks

N/A

6.2.1 Separation requirements N/A 6.2.2 Electric strength test procedure N/A 6.2.2.1 Impulse test N/A 6.2.2.2 Steady-state test N/A 6.2.2.3 Compliance criteria N/A

Page 196: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 28 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

6.3 Protection of the telecommunication wiring system from overheating N/A Max. output current (A) .......................................... : -

Current limiting method.......................................... : -

7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N/A 7.1 Protection of cable distribution system service persons, and users of other

equipment connected to the system, from hazardous voltages in the equipment N/A

7.2 Protection of equipment users from overvoltages on the cable distribution system

N/A

7.3 Insulation between primary circuits and cable distribution systems

N/A

7.3.1 General N/A 7.3.2 Voltage surge test N/A 7.3.3 Impulse test N/A

A Annex A, TESTS FOR RESISTANCE TO HEAT AND FIRE Pass A.1 Flammability test for fire enclosures of movable equipment having a total mass

exceeding 18 kg, and of stationary equipment (see 4.7.3.2) Pass

A.1.1 Samples................................................................. : 3 samples of the entire front bezel were used.

-

Wall thickness (mm) .............................................. : 0.9 mm - A.1.2 Conditioning of samples; temperature (°C) ........... : 86 °C Pass A.1.3 Mounting of samples.............................................. : The samples were mounted as

the would be in the product. Pass

A.1.4 Test flame Pass A.1.5 Test procedure Pass A.1.6 Compliance criteria Pass

Sample 1 burning time (s)...................................... : -

Sample 2 burning time (s)...................................... : -

Sample 3 burning time (s)...................................... : -

Page 197: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 29 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see 4.7.3.2 and 4.7.3.4)

N/A

A.2.1 Samples, material .................................................. : -

Wall thickness (mm) .............................................. : - A.2.2 Conditioning of samples N/A A.2.3 Mounting of samples N/A A.2.4 Test flame N/A A.2.5 Test procedure N/A A.2.6 Compliance criteria N/A

Sample 1 burning time (s)...................................... : -

Sample 2 burning time (s)...................................... : -

Sample 3 burning time (s)...................................... : - A.2.7 Alternative test acc. to IEC 60695-2-2, cl. 4, 8 N/A

Sample 1 burning time (s)...................................... : -

Sample 2 burning time (s)...................................... : -

Sample 3 burning time (s)...................................... : -

A.3 Hot flaming oil test (see 4.6.2) N/A A.3.1 Mounting of samples N/A A.3.2 Test procedure N/A A.3.3 Compliance criterion N/A

Page 198: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 30 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

B Annex B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see 4.7.2.2 and 5.3.2)

Pass

B.1 General requirements Pass

Position .................................................................. : Only d.c. motors in SECONDARY CIRCUITS.

-

Manufacturer.......................................................... : See table 1.5.1. -

Type....................................................................... : See table 1.5.1. -

Rated values.......................................................... : See table 1.5.1. - B.2 Test conditions Pass B.3 Maximum temperatures (see appended table 5.3) Pass B.4 Running overload test N/A B.5 Locked-rotor overload test N/A

Test duration (days)............................................... : -

Electric strength test: test voltage (V).................... : - B.6 Running overload test for d.c. motors in secondary

circuits N/A

B.7 Locked-rotor overload test for d.c. motors in secondary circuits Pass B.7.1 Test procedure (see appended table 5.3) Pass B.7.2 Alternative test procedure; test time (h)................. : The motors was operated with

the rotor locked for 7 h. Pass

B.7.3 Electric strength test N/A B.8 Test for motors with capacitors N/A B.9 Test for three-phase motors N/A B.10 Test for series motors N/A

Operating voltage (V)............................................. : -

Page 199: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 31 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

C Annex C, TRANSFORMERS (see 1.5.4 and 5.3.3) Pass Position .................................................................. : T200, T201, T202 -

Manufacturer.......................................................... : See table 1.5.1. -

Type....................................................................... : See table 1.5.1. -

Rated values.......................................................... : See table 1.5.1. -

Method of protection .............................................. : - C.1 Overload test (see appended table 5.3) Pass C.2 Insulation (see appended table 5.2) Pass Protection from displacement of windings ............. : Margin tape provided on each

end of each winding. Pass

D Annex D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS Pass D.1 Measuring instrument Pass D.2 Alternative measuring instrument N/A

E Annex E, TEMPERATURE RISE OF A WINDING Pass

F Annex F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10)

Pass

Page 200: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 32 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

G Annex G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES

N/A

G.1 Summary of the procedure for determining minimum clearances

N/A

G.2 Determination of mains transient voltage (V) N/A G.2.1 AC mains supply N/A G.2.2 DC mains supply N/A G.3 Determination of telecommunication network

transient voltage (V) :............................................. : N/A

G.4 Determination of required withstand voltage (V) ... : N/A G.5 Measurement of transient levels (V)...................... : N/A G.6 Determination of minimum clearances .................. : N/A

H ANNEX H, IONIZING RADIATION (see 4.3.13) N/A

J Annex J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) Pass Metal used ............................................................. : -

K ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7) N/A K.1 Making and breaking capacity N/A K.2 Thermostat reliability; operating voltage (V) .......... : N/A K.3 Thermostat endurance test; operating voltage (V) : N/A K.4 Temperature limiter endurance; operating voltage

(V) .......................................................................... : N/A

K.5 Thermal cut-out reliability N/A K.6 Stability of operation N/A

Page 201: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 33 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

L Annex L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1)

Pass

L.1 Typewriters N/A L.2 Adding machines and cash registers N/A L.3 Erasers N/A L.4 Pencil sharpeners N/A L.5 Duplicators and copy machines N/A L.6 Motor-operated files N/A L.7 Other business equipment Operating at rated output load. Pass

M Annex M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N/A M.1 Introduction N/A M.2 Method A N/A M.3 Method B N/A M.3.1 Ringing signal N/A M.3.1.1 Frequency (Hz) ...................................................... : - M.3.1.2 Voltage (V)............................................................. : - M.3.1.3 Cadence; time (s), voltage (V)............................... : - M.3.1.4 Single fault current (mA) ........................................ : - M.3.2 Tripping device and monitoring voltage................. : N/A M.3.2.1 Conditions for use of a tripping device or a

monitoring voltage N/A

M.3.2.2 Tripping device N/A M.3.2.3 Monitoring voltage (V)............................................ : N/A

N Annex N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and clause G.5)

N/A

N.1 ITU-T impulse test generators N/A N.2 IEC 60065 impulse test generator N/A

Page 202: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 34 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

P Annex P, NORMATIVE REFERENCES Pass

Q Annex Q, BIBLIOGRAPHY Pass

R Annex R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES

N/A

R.1 Minimum separation distances for unpopulated coated printed boards (see 2.10.6)

N/A

R.2 Reduced clearances (see 2.10.3) N/A

S Annex S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) N/A S.1 Test equipment N/A S.2 Test procedure N/A S.3 Examples of waveforms during impulse testing N/A

T Annex T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2)

Pass

............................................................................... : IPX0 -

U Annex U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see 2.10.5.4)

Pass

............................................................................... : See enclosure 8-01 for details. -

Page 203: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 35 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.5.1 TABLE: list of critical components Pass

Object/part No. Manufacturer/ trademark

type/model technical data Product Category CCN(s)

Required Marks of Conformity

Supplement ID

Enclosure (Bottom) (mech/fire)

Various Metal min 1 mm thick - -

Enclosure (Top) (mech/fire)

Various Aluminum min 1.9 mm thick - -

Heat sink (left and Right side)

Various (metal material) min 5 mm thick. See enclosure for details.

- -

Front Bezel LG Chemical Ltd GN-5001TF 5V, min 1.5 mm thick. See enclosure for details.

QMFZ2 -

Face plate (Decorative part)

LG Chemical Ltd GN-5001TF HB, min 0.8mm thick. Tested according to HB75

QMFZ2 -

Capacitor (C100, C108) Arcotronics R.46 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Vishay F1772 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C100, C108) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 1.0 uF

FOWX2 UL

Capacitor (C101, C102, C106)

Arcotronics R.46 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Arcotronics 1.40 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Vishay F1772 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C101, C102, C106) Alternate

Xiamen Faratronic MKP62 Line-to-Line; 250 V, 680 nF

FOWX2 UL

Capacitor (C103, C104, C138,C139)

Murata Type KH Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, Matsushita Type TS Line-to-Earth; FOKY2 UL

Page 204: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 36 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

C138,C139) Alternate

250 V, 4.7 nF

Capacitor (C103, C104, C138,C139) Alternate

Vishay WYO Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139) Alternate

Xiamen Faratronic MKP62 Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C103, C104, C138,C139) Alternate

TDK CS Line-to-Earth; 250 V, 4.7 nF

FOKY2 UL

Capacitor (C142) Arcotronics R.41 Line-to-Earth; 250 V, 22 nF

FOKY2 UL

Capacitor (C142) Alternate

Evox Rifa PME271Y Line-to-Earth; 250 V, 22 nF

FOKY2 UL

Inductor (L100, L101) Eltek Energy AS 103293 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L100) Alternate

Eltek Energy AS 106347 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Fuse (F100, F101) Littelfuse 324015 Rated: 250 V, 15 A

JDYX2 -

Fuseholder Ashadi Glass Matex Co., Ltd.

RG-40JA Rated V-0, Min. 1.0mm thick QMFZ2 UL

Fuseholder Alternate

Chevron Philips R-7 02 Rated V-0, Min. 1.0mm thick QMFZ2 UL

Varistor (VDR100) Epcos S14K420 420V (line-to-line) XUHT2 UL

Page 205: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 37 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Relay (REL100) Various Various Contact rated: 250 V, 16 A Coil rated: 12 Vdc

NLDX2 UL

Inductor (L102) Eltek Energy AS 106077 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Inductor (L102) Alternative

Eltek Energy AS 101545 Copper magnet wire wound on Toroid core. See enclosure for details

- -

Voltage Regulator (U100)

Nacional Semiconductor

LM317AT Rated 1.2 - 37 V, 1.5 A

- -

Voltage Regulator (U100) Alternate

On Semiconductor LM317BT Rated 1.2 - 37 V, 1.5 A

- -

Transformer (T200) Eltek 105103 Open type construction Copper magnet winding wound on bobbin Provided with OBJY2 Class F insulation system designated AYX 155F See enclosure for details.

OBJY2 -

Transformer (T201) Eltek 105103 Open type construction Copper magnet winding wound on bobbin Provided with OBJY2 Class F

OBJY2 -

Page 206: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 38 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

insulation system designated AYX 155F See enclosure for details.

Transformer (T202) Eltek Energy AS 101543 Open type construction Class A insulation system Copper magnet winding wound on split bobbin See enclosure for details.

- -

Inductor (L202) Eltek 392717 or 205729 Copper magnet wire wound on Toroid core. See enclosure for details.

- -

Opto Coupler (ISO200, ISO201, ISO202)

Vishay TCLT1003 Double protection, provides 3750 Vac isolation

FPQU2 UL

Opto Coupler (ISO200, ISO201, ISO202) Alternate

Infineon SFH6156 (System H and J)

Double protection, provides 4420 Vac isolation

FPQU2 UL

Connector (CON 100) (Primary and SELV)

Elcon / Tyco 284-0472-15000C Rated: 250 V, 35 A

ECBT2, RTRT2 UL

Fan (Two provided) Sanyo Denki 109P0412J3153 Rated: 16.3CFM 12 Vdc, 0.35 A

GPWV2 UL

Fan (Two provided) Alternate

Sunon PMO1204PQB1-A

Rated: 17.6 CFM 12 Vdc, 0.39 A

GPWV2 UL

Insulation between metal enclosure and PWB

Dupont Melinex 226 Minimum 0.188 mm thick, rated VTM-2.

QMFZ2 -

Page 207: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 39 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

And above electrolytic capacitors Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Toray Lumirror S10 Minimum 0.188 mm thick, rated VTM-2.

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Dupont Nomex 410 Minimum 0.188 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-5BK Minimum 0.12 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-10 Minimum 0.25 mm thick, rated V-0

QMFZ2 -

Insulation between metal enclosure and PWB And above electrolytic capacitors (Alternate)

Formex Formex GK-17 Minimum 0.43 mm thick, rated V-0

QMFZ2 -

Insulation between Switch transistors/diodes

Pioneer Conductor Rubber

PMP-P-100 Min. 0.15mm thick, rated V-0, 150°C

QMFZ2 -

Page 208: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 40 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

and HeatSink Insulation between Switch transistors/diodes and HeatSink Alternate

Pioneer Conductor Rubber

PMP-P-500A 0.16 - 0.18mm thick, rated V-0, 150°C

QMFZ2 -

PWB Various Various Rated:V-0, 130°C ZPMV2 UL Components in Flatpack2 1800W 48V only

- - - - -

Rectifier (DB100) Rectron RS1507M Rated min. 1000 V, 15 A - - Rectifier (DB100) Alternate

Wontop GBJ15M Rated min. 1000 V, 15 A - -

Diode (D104) Infineon SDT12S60 Rated min. 600 V, 12 A - - Electrolytic Capacitors (C110-C114, C200)

Various Various Rated: 450 V, 150 uF, 105 °C

- -

Switch Transistor (Q103) Infineon Q67040-S4491 (SPW47N60C3)

Rated min. 600 V, 47 A - -

Switch Transistor (Q105) Fairchild FQA19N60 Rated min. 600 V, 19 A - - Switch Transistor (Q200, Q201)

Infineon SPW32N50C3 Rated min. 500 V, 32 A - -

Inductor (L200) Eltek 104697 Open type construction Copper magnet winding wound on bobbin See enclosure for details.

- -

Transformer (T100, T101)

Eltek 102620 Open type construction. Core: Ferrite. Outer diameter 17 mm, Inner diameter 9 mm, width 7 mm including coil.

- -

Page 209: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 41 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Coil: Triple insulated wire Furukawa Electric, Type: TEX-E. See enclosure for details.

Electrolytic Capacitors (C211-C215, C217)

Various Various Rated: 63 V, 470 uF, 105 C

- -

Components in Flatpack2 2000W 48V only

- - - - -

Rectifier (DB100) Wontop elctronics GBJ25M Rated min. 1000 V, 25 A - - Rectifier (DB100) Alternate

Rectron RS2507M Rated min. 1000 V, 25 A - -

Inductor (L103) KASCHKE KG GMBH & CO.

060.166 Copper magnet wire wound on ferrite core. See enclosure for details

- -

Diode (D103) Fairchild Semiconductor

ISL9R460PF2 Rated min. 600 V, 4 A - -

Diode (D104) ST Microelectronics STTH30R06CW Rated min. 600 V, 15 A - - Electrolytic Capacitors (C112-C114, C200)

Various Various Rated: 450 V, 220 uF, 105 °C

- -

Switch Transistor (Q103) Infineon SPW35N60C3 Rated min. 600 V, 34 A - - Switch Transistor (Q105) Fairchild

Semiconductor FCP7N60 Rated min. 600 V, 7 A - -

Switch Transistor (Q200, Q201)

Infineon SPW47N60C3 Rated min. 600 V, 47 A - -

Capacitor (C105) Murata KX Line-to-Earth; 250 V, 1nF

FOWX2 UL

Capacitor (C105)

Murata KH Line-to-Earth; 250 V, 1nF

FOKY2 UL

Page 210: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 42 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Alternate Capacitor (C105) Alternate

Matsushita Type TS Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Vishay WYO Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

Xiamen Faratronic MKP62 Line-to-Earth; 250 V, 1nF

FOKY2 UL

Capacitor (C105) Alternate

TDK CS Line-to-Earth; 250 V, 1nF

FOKY2 UL

Inductor (L200) Eltek 204274 Open type construction Copper magnet winding wound on bobbin Same material specification as 104697, difference is only number of turns. See enclosure for details.

- -

Transformer (T100, T101)

Eltek 204667 Open type construction. Core: Ferrite. Copper magnet winding wound on bobbin See enclosure for details.

- -

Bobbin on Transformer (T100, T101

Sumitomo Bakelite PM-9630 Phenolic, V-0, 150 C, min. 1.2mm thick

QMFZ2 -

Electrolytic Capacitors (C211-C215, C217, C232, C236)

Various Various Rated: 63 V, 470 uF, 105 °C

- -

Page 211: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 43 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Page 212: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 44 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.6.2 TABLE: electrical data (in normal conditions) Pass

fuse # I rated (A) U (V) P (W) I (mA) I fuse (mA) condition/status Flatpack2 1800W 48V

F100, F101

11.0 max 85, 50 Hz 810 9400 9400 Output load: 52.3 Vdc 13.3 A

F100, F101

11.0 max 100, 50 Hz 971 9700 9700 Output load: 52.3 16.0

F100, F101

11.0 max 120, 50 Hz 1278 11300 11300 Output load: 52.3 20.8

F100, F101

11.0 max 185, 50 Hz 1994 10700 10700 Output load: 52.0 33.6

F100, F101

11.0 max 220, 50 Hz 1982 9000 9000 Output load: 52.3 33.6

F100, F101

11.0 max 230, 50 Hz 1977 8600 8600 Output load: 52.3 33.6

F100, F101

11.0 max 240, 50 Hz 1960 8200 8200 Output load: 52.3 33.6

F100, F101

11.0 max 242, 50 Hz 1974 8100 8100 Output load: 52.3 33.6

F100, F101

11.0 max 254, 50 Hz 1976 7800 7800 Output load: 52.3 33.6

F100, F101

11.0 max 276, 50 Hz 1973 7100 7100 Output load: 52.3 33.6

F100, F101

11.0 max 85, 50 Hz 794 9200 9200 Output load: 48.1 14.0

F100, F101

11.0 max 100, 50 Hz 972 9700 9700 Output load: 48.1 17.4

F100, F101

11.0 max 120, 50 Hz 1284 11100 11100 Output load: 48.1 22.4

F100, F101

11.0 max 185, 50 Hz 2008 10900 10900 Output load: 48.1

Page 213: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 45 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

36.0 F100, F101

11.0 max 220, 50 Hz 1984 9000 9000 Output load: 48.1 36.0

F100, F101

11.0 max 230, 50 Hz 1985 8600 8600 Output load: 48.1 36.0

F100, F101

11.0 max 240, 50 Hz 1982 8300 8300 Output load: 48.1 36.0

F100, F101

11.0 max 242, 50 Hz 1980 8200 8200 Output load: 48.1 36.0

F100, F101

11.0 max 254, 50 Hz 1973 7800 7800 Output load: 48.1 36.0

F100, F101

11.0 max 264, 50 Hz 1970 7500 7500 Output load: 48.1 36.0

F100, F101

11.0 max 85, 60 Hz 807 9400 9400 Output load: 52.3 Vdc 13.1

F100, F101

11.0 max 100, 60 Hz 991 9800 9800 Output load: 52.3 16.3

F100, F101

11.0 max 120, 60 Hz 1270 11100 11100 Output load: 52.3 20.3

F100, F101

11.0 max 185, 60 Hz 1990 10700 10700 Output load: 52.0 33.6

F100, F101

11.0 max 220, 60 Hz 1976 9000 9000 Output load: 52.3 33.6

F100, F101

11.0 max 230, 60 Hz 1977 8600 8600 Output load: 52.3 33.6

F100, F101

11.0 max 240, 60 Hz 1975 8200 8200 Output load: 52.3 33.6

F100, F101

11.0 max 242, 60 Hz 1968 8100 8100 Output load: 52.3 33.6

F100, F101

11.0 max 254, 60 Hz 1972 7700 7700 Output load: 52.3 33.6

F100, F101

11.0 max 264, 60 Hz 1963 7500 7500 Output load: 52.3

Page 214: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 46 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

33.6 F100, F101

11.0 max 85, 60 Hz 796 9200 9200 Output load: 48.1 14.0

F100, F101

11.0 max 100, 60 Hz 983 9700 9700 Output load: 48.1 17.5

F100, F101

11.0 max 120, 60 Hz 1263 11000 11000 Output load: 48.1 22.0

F100, F101

11.0 max 185, 60 Hz 2005 10800 10800 Output load: 48.1 36.0

F100, F101

11.0 max 220, 60 Hz 1987 9100 9100 Output load: 48.1 36.0

F100, F101

11.0 max 230, 60 Hz 1978 8600 8600 Output load: 48.1 36.0

F100, F101

11.0 max 240, 60 Hz 1984 8300 8300 Output load: 48.1 36.0

F100, F101

11.0 max 242, 60 Hz 1990 8200 8200 Output load: 48.1 36.0

F100, F101

11.0 max 254, 60 Hz 1982 7800 7800 Output load: 48.1 36.0

F100, F101

11.0 max 264, 60 Hz 1974 7500 7500 Output load: 48.1 36.0

Flatpack2 2000W 48V

F100/ F101

12.5 max 85, 50Hz 976 11450 11450 Normal load: 53.3V, 15.6A

F100/ F101

12.5 max 100, 50Hz 1010 10100 10100 Normal load: 53.3V, 16.6A

F100/ F101

12.5 max 120, 50Hz 1345 11210 11210 Normal load: 53.2V, 22.4A

F100/ F101

12.5 max 185, 50Hz 2189 11850 11850 Normal load: 52.9V, 37.4A

F100/ F101

12.5 max 220, 50Hz 2161 9917 9917 Normal load: 52.9V, 37.4A

F100/ F101

12.5 max 230, 50Hz 2156 9451 9451 Normal load: 52.9V, 37.4A

F100/ 12.5 max 250, 50Hz 2152 8685 8685 Normal load:

Page 215: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 47 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

F101 53.0V, 37.3A F100/ F101

12.5 max 275, 50Hz 2133 7896 7896 Normal load: 53.0V, 37.3A

F100/ F101

12.5 max 85, 60Hz 977 11440 11440 Normal load: 53.3V, 15.6A

F100/ F101

12.5 max 100, 60Hz 1015 10110 10110 Normal load: 53.3V, 16.7A

F100/ F101

12.5 max 120, 60Hz 1347 11200 11200 Normal load: 53.2V, 22.3A

F100/ F101

12.5 max 185, 60Hz 2181 11730 11730 Normal load: 52.7V, 37.2A

F100/ F101

12.5 max 220, 60Hz 2171 9942 9942 Normal load: 53.0V, 37.4A

F100/ F101

12.5 max 230, 60Hz 2163 9504 9504 Normal load: 53.0V, 37.5A

F100/ F101

12.5 max 250, 60Hz 2151 8653 8653 Normal load: 53.0V, 37.4A

F100/ F101

12.5 max 275, 60Hz 2137 7852 7852 Normal load: 53.0V, 37.4A

supplementary information:

The Power supply reduces the output current when input voltage decrease below 185 Vac. The steady state input current did not exceed the rated current at the rated voltage by more than 10 percent under maximum normal load.

2.10.3 and 2.10.4

TABLE: clearance and creepage distance measurements Pass

clearance cl and creepage distance dcr at/of:

Up (V)

U r.m.s. (V) required cl (mm)

cl (mm) required dcr (mm)

dcr (mm)

1800 W version (Flatpack2 1800W 48V)

L-N before fuse 325 230 2.0 2.5 2.5 2.5 T201: Pin 4 - Pin 5 488 224 4.2 6 5.0 6 Pin 4 - Pin 6&7* 424 198 4.2 6 5.0 6 Pin 4 - Pin 8 368 172 4.2 6 5.0 6 Pin 2&3* - Pin 5 384 192 4.2 6 5.0 6 Pin 2&3* - Pin 6&7* 304 171 4.2 6 5.0 6 Pin 2&3* - Pin 8 256 155 4.2 6 5.0 6 Pin 1 - Pin 5 320 171 4.2 6 5.0 6 Pin 1 - Pin 6&7* 264 161 4.2 6 5.0 6 Pin 1 - Pin 8 296 157 4.2 6 5.0 6 Pin 4 - Earth 272 171 2.0 6 2.5 6 Pin 5 - Earth 400 177 2.0 6 2.5 6 T200:

Page 216: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 48 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin 4 - Pin 5 408 181 4.2 6 5.0 6 Pin 4 - Pin 6&7* 264 158 4.2 6 5.0 6 Pin 4 - Pin 8 318 163 4.2 6 5.0 6 Pin 2&3* - Pin 5 344 164 4.2 6 5.0 6 Pin 2&3* - Pin 6&7* 336 163 4.2 6 5.0 6 Pin 2&3* - Pin 8 376 182 4.2 6 5.0 6 Pin 1 - Pin 5 352 170 4.2 6 5.0 6 Pin 1 - Pin 6&7* 376 190 4.2 6 5.0 6 Pin 1 - Pin 8 360 196 4.2 6 5.0 6 Pin 4 - Earth 384 171 2.0 3.4 2.5 3.4 Pin 5 - Earth 208 63 2.0 3.4 2.5 3.4 T202 Pin 1 - Pin 6 324 176 4.0 7.8 5.0 7.8 Pin 1 - Pin 7 348 195 4.0 7.8 5.0 7.8 Pin 1 - Pin 8 364 216 4.0 7.8 5.0 7.8 Pin 2 - Pin 6 340 194 4.0 7.8 5.0 7.8 Pin 2 - Pin 7 324 190 4.0 7.8 5.0 7.8 Pin 2 - Pin 8 304 178 4.0 7.8 5.0 7.8 Pin 3 - Pin 6 424 192 4.0 7.8 5.0 7.8 Pin 3 - Pin 7 404 187 4.0 7.8 5.0 7.8 Pin 3 - Pin 8 384 182 4.0 7.8 5.0 7.8 Pin 4 - Pin 6 448 197 4.0 7.8 5.0 7.8 Pin 4 - Pin 7 432 177 4.0 7.8 2.5 7.8 Pin 4 - Pin 8 408 181 4.0 7.8 2.5 7.8 Pin 5 - Pin 6 464 197 4.0 7.8 2.5 7.8 Pin 5 - Pin 7 440 201 4.0 7.8 2.5 7.8 Pin 5 - Pin 8 420 191 4.0 7.8 2.5 7.8 Q103 Pin 1 - Earth 424 193 2.1 3.4 2.5 3.4 Pin 2 - Earth 392 208.5 2.1 3.4 2.5 3.4 Pin 3 - Earth 428 195.1 2.1 3.4 2.5 3.4 D104 Pin 1 - Earth 396 199.9 2.2 3.4 2.5 3.4 Pin 2 - Earth 544 358.3 2.2 3.4 2.5 3.4 Q105 Pin 1 - Earth 400 190.3 2.1 3.4 2.5 3.4 Pin 2 - Earth 436 199 2.1 3.4 2.5 3.4 Pin 3 - Earth 400 186.9 2.1 3.4 2.5 3.4 Q200 Pin 1 - Earth 360 213.5 2.2 3.4 3.8 3.8 Pin 2 - Earth 544 377.8 2.2 3.4 3.8 3.8 Pin 3 - Earth 364 212.1 2.2 3.4 3.8 3.8 Q201 Pin 1 - Earth 444 205 2.1 3.4 2.5 3.4 Pin 2 - Earth 348 186.8 2.1 3.4 2.5 3.4

Page 217: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 49 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin 3 - Earth 428 204.5 2.1 3.4 2.5 3.4 U100 Pin 1 - Earth 408 144.8 2.1 5.5 2.5 5.5 Pin 2 - Earth 420 196.2 2.1 5.5 2.5 5.5 Pin 3 - Earth 428 183.6 2.1 5.5 2.5 5.5 ISO 200 Pin 4 - Pin 1 404 192 4.0 8.2 5.0 8.2 Pin 3 - Pin 2 416 172 4.0 8.2 5.0 8.2 ISO 201 Pin 1 - Pin 3 428 188 4.0 8.2 5.0 8.2 Pin 2 - Pin 4 444 208 4.0 8.2 5.0 8.2 ISO 202 Pin 4 - Pin 1 412 191 4.0 8.2 5.0 8.2 Pin 3 - Pin 2 416 178 4.0 8.2 5.0 8.2 2000 W version (Flatpack2 2000W 48V)

- - - - - -

L-N before fuse 354 250 2.0 2.5 2.5 2.5 T201 Pin4 - Pin5 442 210 4.4 5.6 5.0 5.6 Pin4 - Pin6&7* 378 195 4.4 5.6 5.0 5.6 Pin4 - Pin8 406 196 4.4 5.6 5.0 5.6 Pin2&3* - Pin5 410 195 4.4 6.3 5.0 6.3 Pin2&3* - Pin6,&7* 406 195 4.4 6.3 5.0 6.3 Pin2&3* - Pin8 454 210 4.4 6.3 5.0 6.3 Pin1 - Pin5 402 193 4.4 6.1 5.0 6.1 Pin1 - Pin6&7* 442 205 4.4 6.1 5.0 6.1 Pin1 - Pin8 494 230 4.4 6.1 5.0 6.1 Pin4 - Earth 370 195 2.0 4.7 2.5 4.7 Pin5 - Earth 92 55 2.0 4.9 2.5 4.9 T200 Pin4 - Pin5 426 193 4.6 8.0** 6.4 8.0** Pin4 - Pin6&7* 442 205 4.6 8.0** 6.4 8.0** Pin4 - Pin8 494 230 4.6 8.0** 6.4 8.0** Pin2&3* - Pin5 442 205 4.6 8.0** 6.4 8.0** Pin2&3* - Pin6&7* 490 229 4.6 8.0** 6.4 8.0** Pin2&3* - Pin8 545 264 4.6 8.0** 6.4 8.0** Pin1 - Pin5 460 221 4.6 8.0** 6.4 8.0** Pin1 - Pin6&7* 516 254 4.6 8.0** 6.4 8.0** Pin1 - Pin8 568 294 4.6 8.0** 6.4 8.0** Pin5 - Earth 71,6 53,3 2.0 4.9 2.5 4.9 T202 Pin1 - Pin6 430 248 4.2 6.4** 5.0 6.4** Pin1 - Pin7 453 262 4.2 6.4** 5.4 6.4** Pin1 - Pin8 470 277 4.2 6.4** 5.8 6.4** Pin2 - Pin6 267 168 4.0 6.4** 5.0 6.4**

Page 218: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 50 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Pin2 - Pin7 245 167 4.0 6.4** 5.0 6.4** Pin2 - Pin8 256 168 4.0 6.4** 5.0 6.4** Pin3 - Pin6 356 165 4.0 8.2 5.0 8.2 Pin3 - Pin7 367 166 4.0 8.4 5.0 8.4 Pin3 - Pin8 386 167 4.0 10.2 5.0 10.2 Pin4 - Pin6 364 166 4.0 8.2 5.0 8.2 Pin4 - Pin7 348 165 4.0 8.4 5.0 8.4 Pin4 - Pin8 370 166 4.0 10.2 5.0 10.2 Pin5 - Pin6 370 163 4.0 7.5 5.0 7.5 Pin5 - Pin7 350 160 4.0 7.5 5.0 7.5 Pin5 - Pin8 341 159 4.0 7.5 5.0 7.5 Q103 Pin1 – Earth 342 162 2.0 3.2 2.5 3.2 Pin2 - Earth 486 243 2.1 3.2 2.5 3.2 Pin3 – Earth 338 165 2.0 3.2 2.5 3.2 D104 Pin1 – Earth 450 244 2.1 2.5 2.5 3.0 Pin2 - Earth 450 337 2.1 2.9 3.5 4.0 Q105 Pin1 – Earth 326 156 2.0 5.6 2.5 5.6 Pin2 - Earth 358 164 2.0 5.6 2.5 5.6 Pin3 – Earth 322 155 2.0 5.6 2.5 5.6 Q200 Pin1 – Earth 338 162 2.0 5.0 2.5 5.0 Pin2 - Earth 442 259 2.1 5.0 2.7 5.0 Pin3 – Earth 338 165 2.0 5.0 2.5 5.0 Q201 Pin1 – Earth 446 264 2.1 5.0 2.7 5.0 Pin2 - Earth 442 338 2.1 5.0 3.6 5.0 Pin3 – Earth 438 259 2.1 5.0 2.7 5.0 U100 Pin1 – Earth 334 161 2.0 5.5 2.5 5.5 Pin2 - Earth 334 161 2.0 5.5 2.5 5.5 Pin3 – Earth 322 154 2.0 5.5 2.5 5.5 ISO200 Pin1-Pin3 345 175 4.0 7.0 5.0 7.0 Pin1-Pin4 326 157 4.0 7.0 5.0 7.0 Pin2- Pin3 334 160 4.0 7.0 5.0 7.0 Pin2- Pin4 330 157 4.0 7.0 5.0 7.0 Pin3 – Earth 346 173,3 2.0 4.1 2.5 4.1 ISO201 Pin1-Pin3 340 166 4.0 7.0 5.0 7.0 Pin1-Pin4 358 176 4.0 7.0 5.0 7.0 Pin2- Pin3 345 166 4.0 7.0 5.0 7.0 Pin2- Pin4 360 176 4.0 7.0 5.0 7.0

Page 219: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 51 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

ISO202 Pin1-Pin3 340 164 4.0 7.0 5.0 7.0 Pin1-Pin4 325 155 4.0 7.0 5.0 7.0 Pin2- Pin3 340 164 4.0 7.0 5.0 7.0 Pin2- Pin4 326 154 4.0 7.0 5.0 7.0 supplementary information:

*)Terminals directly connected to each other. **) Distance represents an internal measurement. For 2000 W version: Measurement is performed with a reference to earth and measured the difference between primary and secondary side of the measured component. ISO203 is not mounted.

2.10.5 TABLE: distance through insulation measurements Pass

distance through insulation di at/of: Up (V)

test voltage (V) required di (mm)

di (mm)

Flatpack2 1800W 48V - - - - Thin sheet material used inside T200, T201 230 4243 2 layers 2 layers Split bobbin T202 230 4243 0.4 0.58 Insulation material between pwb and metal enclosure

230 2121 - 0.188

Insulation material between pwb and metal enclosure

230 2121 - 0.43

Insulation material between switch transistors/diodes and heat sink

230 2121 - 0.15

Flatpack2 2000W 48V - - - - Thin sheet material used inside T200, T201 568 4250 2 layers 2 layers Split bobbin T202 470 4250 0.4 0.58 Insulation between PWB and bottom of chassis 450 2400 - Min. 0.12 Insulation between PWB and top chassis 450 2400 - Min. 0.18 Insulation between switch transistors/diodes and Heat sink

450 2400 - 0.15

All models - - - - Insulation Formex GK-5BK (used as alternative insulation between PWB and chassis)

450 2400 - 0.12

Insulation Formex GK-10 (used as alternative insulation between PWB and chassis)

450 2400 - 0.25

Insulation Formex GK-17 (used as alternative insulation between PWB and chassis)

450 2400 - 0.43

supplementary information: There were no indication of break down.

4.5 TABLE: temperature rise measurements Pass test voltage (V) ......................................... See See See See See below —

Page 220: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 52 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

below below below below t1 (°C)........................................................ See

belowSee below

See below

See below

See below —

t2 (°C)........................................................ See below

See below

See below

See below

See below —

maximum temperature T of part/at: T (°C) allowed Tmax (°C)

Flatpack2 1800W 48V Input Condition : 205 V, 50 Hz, 9.6A, 1960W, duration 2 hours ; Output Condition : 48.5 Vdc, 35.4 A

Input Condition : 240 V, 60 Hz, 8.3 A, 1976 W, duration 55 min ; Output Condition : 48.0 Vdc, 35.4 A

Input Condition : 240 V, 50 Hz, 8.3 A, 1970 W, duration 40 min ; Output Condition : 48 Vdc, 35.4 A

-- -- --

Ambient (t2) 27.6 27.9 27.5 -- -- -- 1. Connector CON100 (primary) (housing) 65.4 62.2 61.6 -- -- -- 2. X – Capacitor C100 76.9 69.4 68.9 -- -- 105 3. Inductor L100 (windings) 95.0 81.9 81.4 -- -- 155 4. X Capacitor C101 65.0 59.8 59.2 -- -- 105 5. Inductor L101 73.3 65.6 65.0 -- -- 155 6. Fuse F100 66.1 60.4 59.8 -- -- -- 7. Not Connected -- -- -- -- -- -- 8. X Capacitor C102 51.9 49.9 49.3 -- -- 105 9. Inductor L102 79.0 71.0 70.4 -- -- 155 10. PWB near CON100 (Primary) didn’t work during this test

-- -- -- -- -- --

11. PWB near DB100 71.4 67.7 67.0 -- -- 130 12. Electrolytic Capacitor (top) C200 46.6 46.7 46.2 -- -- 105 13. Electrolytic Capacitor (top) C113 38.2 38.9 38.5 -- -- 105 14. Inductor L200 (core) 53.8 56.1 55.2 -- -- 155 15. Inductor L200 (windings) 69.6 72.9 71.7 -- -- 155 16. Transformer T202 (windings) 33.9 34.4 33.5 -- -- 90 17. Main Transformer T200 (windings) 87.1 91.9 90.6 -- -- 130

Page 221: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 53 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

18. Main Transformer T200 (core) 68.8 71.8 70.6 -- -- 130 19. Main Transformer T201 (windings) 102.2 108.7 107.5 -- -- 130 20. Main Transformer T201 (core) 92.1 97.9 96.7 -- -- 130 21. PWB near D207 87.6 92.5 91.6 -- -- 130 22. Electrolytic capacitor C213 (top) 67.7 70.9 70.0 -- -- 105 23. Inductor L201 (windings) 72.8 76.8 75.8 -- -- 155 24. Inductor L202 (windings) 86.7 91.2 90.4 -- -- 155 25. PWB near output connector CON100 (SELV)

89.3 93.3 92.5 -- -- 130

26. Output connector CON100 (SELV) (housing)

85.2 89.1 88.2 -- -- --

27. Heat sink left 72.8 70 69.4 -- -- -- 28. Heat sink right 84.8 87.3 86.9 -- -- -- 29. Front bezel 27.5 28 26.8 -- -- 95 Flatpack2 1800W 48V Input

Condition: 205 V, 50 Hz, 9.7 A, 1965 W, duration 1 h 20 min; Output Condition: 48 Vdc, 36.1 A

Input Condition: 205 V, 50 Hz, 8.7 A, 1770 W, duration 55 min; Output Condition: 48 Vdc, 32.5 A

Input Condition: 205 V, 50 Hz, 6.7 A, 1350 W, duration 40 min; Output Condition: 47 Vdc, 25.4 A

-- -- --

Ambient (t2) 48.5 56.0 75.4 -- -- -- 1. Connector CON100 (primary) (housing) 70.6 75.5 90.2 -- -- -- 2. X – Capacitor C100 83.3 86.4 98.5 -- -- 105 3. Inductor L100 (windings) 98.4 98.7 105.8 -- -- 155 4. X Capacitor C101 74.4 78.8 93.3 -- -- 105 5. Inductor L101 80.5 84.0 96.5 -- -- 155 6. Fuse F100 76.2 80.2 93.9 -- -- -- 7. Not Connected -- -- -- -- -- -- 8. X Capacitor C102 65.2 71.3 88.4 -- -- 105 9. Inductor L102 86.2 89.7 102.0 -- -- 155 10. PWB near CON100 (Primary) 71.0 76.0 90.9 -- -- -- 11. PWB near DB100 73.4 78.5 93.7 -- -- 130 12. Electrolytic Capacitor (top) C200 59.4 66.1 84.2 -- -- 105

Page 222: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 54 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

13. Electrolytic Capacitor (top) C113 56.1 63.0 81.3 -- -- 105 14. Inductor L200 (core) 68.1 73.0 89.5 -- -- 155 15. Inductor L200 (windings) 83.7 86.6 99.3 -- -- 155 16. Transformer T202 (windings) 54.2 61.7 81.1 -- -- 90 17. Main Transformer T200 (windings) 97.0 99.0 108.1 -- -- 130 18. Main Transformer T200 (core) 79.8 84.2 97.4 -- -- 130 19. Main Transformer T201 (windings) 105.6 106.6 114.8 -- -- 130 20. Main Transformer T201 (core) 96.1 98.2 108.3 -- -- 130 21. PWB near D207 90.4 92.8 103.2 -- -- 130 22. Electrolytic capacitor C213 (top) 75.8 80.0 94.0 -- -- 105 23. Inductor L201 (windings) 79.2 83.0 96.1 -- -- 155 24. Inductor L202 (windings) 89.9 92.1 101.6 -- -- 155 25. PWB near output connector C100 (SELV) 89.6 92.0 101.2 -- -- 130 26. Output connector C100 (SELV) (housing) 86.6 89.3 99.6 -- -- -- 27. Heat sink left 77.1 81.6 94.8 -- -- -- 28. Ambient temperature inside heating chamber

48.5 56.0 75.4 -- -- --

29. Front bezel 48.8 56.3 75.8 -- -- 95 Flatpack2 1800W 48V Input

Condition: 205 V, 50 Hz, 9.7 A, 1980 W, duration 1 h 10 min ; Output Condition: 48 Vdc, 36.3 A (short-circuit of NTC 200)

Input Condition: 205 V, 50 Hz, 9.7 A, 1960 W, duration 1 h 5 min; Output Condition: 48 Vdc, 36 A (short-circuit of NTC 100 on primary side – main board)

Input Condition: 205 V, 50 Hz, 9.6 A, 1950 W, duration 50 min; Output Condition: 48 Vdc, 36 A (short-circuit of NTC 100 on primary side – main board)

Input Condition: 205 V, 50 Hz, 9.3 A, 1890 W, duration 1 h 10 min ; Output Condition: 48 Vdc, 35.1 A (short-circuit of NTC 100 on the small card)

Input Condition: 210 V, 50 Hz, 0.7 A, 119 W, duration 1 h 25 min ; Output Condition:0.2 Vdc, 29.8 A (short-circuit of the output)

--

Ambient (t2) 48.1 49.2 75.7 47.9 75.0 -- 1. Connector CON100 (primary) (housing) 69.5 71.3 89.8 77.9 80.6 -- 2. X – Capacitor C100 82.9 84.9 97.2 96.3 81.4 --

Page 223: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 55 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

3. Inductor L100 (windings) 99.2 102.2 105.7 115.4 81.5 -- 4. X Capacitor C101 74.4 77.0 92.9 87.4 81.4 -- 5. Inductor L101 79.9 82.6 96.4 93.8 81.4 -- 6. Fuse F100 75.5 77.8 93.6 86.6 81.4 -- 7. Not Connected -- -- -- -- -- -- 8. X Capacitor C102 64.6 66.0 87.8 72.8 81.5 -- 9. Inductor L102 85.3 88.0 102.0 101.8 82.6 -- 10. PWB near CON100 (Primary) 69.5 71.1 90.2 79.8 83.9 -- 11. PWB near DB100 71.8 61.4 97.4 65.6 81.8 -- 12. Electrolytic Capacitor (top) C200 59.6 60.2 83.2 65.7 80.6 -- 13. Electrolytic Capacitor (top) C113 55.4 57.0 80.9 59.7 79.8 -- 14. Inductor L200 (core) 67.3 69.0 88.8 74.5 104.8 -- 15. Inductor L200 (windings) 82.7 85.2 98.7 90.5 117.4 -- 16. Transformer T202 (windings) 53.6 55.0 80.5 55.0 79.9 150 17. Main Transformer T200 (windings) 97.5 99.6 108.2 109.1 105.2 190 18. Main Transformer T200 (core) 79.3 80.2 96.6 89.3 93.0 190 19. Main Transformer T201 (windings) 105.5 109.2 114.7 125.4 109.4 190 20. Main Transformer T201 (core) 94.6 98.3 107.8 114.5 103.8 190 21. PWB near D207 90.8 92.9 103.8 104.4 105.6 -- 22. Electrolytic capacitor C213 (top) 74.5 78.3 94.4 86.5 94.8 -- 23. Inductor L201 (windings) 79.1 80.9 96.3 91.6 97.2 -- 24. Inductor L202 (windings) 88.4 90.4 101.5 102.6 103.2 -- 25. PWB near output connector C100 (SELV) 89.0 91.7 102.0 100.0 103.8 -- 26. Output connector C100 (SELV) (housing) 85.8 88.1 99.9 96.4 101.4 -- 27. Heat sink left 79.6 83.6 100.5 87.2 82.0 -- 28. Ambient temperature inside heating chamber

48.1 49.2 75.7 47.9 75.0 --

29. Front bezel 48.6 49.6 75.8 48.2 75.1 -- -- Input

Condition: 205 V, 50 Hz, 7.8 A, 1650 W, duration 1 h 40 min ; Output Condition: 48 Vdc,

-- -- -- -- --

Page 224: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 56 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

31.5 A (blocked ventilation)

Ambient (t2) 45.1 -- -- -- -- -- 1. Connector CON100 (primary) (housing) 65.4 -- -- -- -- -- 2. X – Capacitor C100 70.5 -- -- -- -- -- 3. Inductor L100 (windings) 88.4 -- -- -- -- -- 4. X Capacitor C101 85.9 -- -- -- -- -- 5. Inductor L101 98.6 -- -- -- -- -- 6. Fuse F100 89.7 -- -- -- -- -- 7. Not Connected -- -- -- -- -- -- 8. X Capacitor C102 96.1 -- -- -- -- -- 9. Inductor L102 122.7 -- -- -- -- -- 10. PWB near CON100 (Primary) 66.0 -- -- -- -- -- 11. PWB near DB100 83.4 -- -- -- -- -- 12. Electrolytic Capacitor (top) C200 91.7 -- -- -- -- -- 13. Electrolytic Capacitor (top) C113 94.0 -- -- -- -- -- 14. Inductor L200 (core) 127.9 -- -- -- -- -- 15. Inductor L200 (windings) 139.2 -- -- -- -- -- 16. Transformer T202 (windings) 94.0 -- -- -- -- 190 17. Main Transformer T200 (windings) 131.0 -- -- -- -- 190 18. Main Transformer T200 (core) 110.1 -- -- -- -- 190 19. Main Transformer T201 (windings) 139.5 -- -- -- -- 190 20. Main Transformer T201 (core) 128.2 -- -- -- -- 190 21. PWB near D207 121.7 -- -- -- -- -- 22. Electrolytic capacitor C213 (top) 101.6 -- -- -- -- -- 23. Inductor L201 (windings) 112.1 -- -- -- -- -- 24. Inductor L202 (windings) 94.9 -- -- -- -- -- 25. PWB near output connector C100 (SELV) 83.7 -- -- -- -- -- 26. Output connector C100 (SELV) (housing) 79.2 -- -- -- -- -- 27. Heat sink left 80.9 -- -- -- -- -- 28. Ambient temperature inside heating chamber

45.1 -- -- -- -- --

29. Front bezel 67.9 -- -- -- -- -- Flatpack2 1800W 48V Transf

ormer T200 and T201 version 5: Input Condition:

Transformer T200 and T201 version 5: Input Condition: 264

Transformer T200 and T201 version 5: Input Condition: 87.2

Transformer T200 and T201 version 5: Input Condition: 187

Transformer T200 and T201 version 5: Input Condition:264.7 Vac, 50 Hz, 6.9 A, 1807 W,

--

Page 225: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 57 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

264 Vac, 50 Hz, 7.4 A, 1945 W, Output Condition: 48 Vdc, 36.1 A

V, 50 Hz, 7.4 A, 1935 W, Output Condition: 52.7 Vdc, 33.1 A

Vac, 50 Hz, 8.4 A, 740 W, Output Condition: 47.2 Vdc, 13.2 A

Vac, 50 Hz, 10.5 A, 1965 W, Output Condition: 48 Vdc, 36.6 A

Output Condition:47.7 Vdc, 33.9 A

Ambient (t2) 24.2 23.6 25.1 24.2 24.2 -- Humidity (2), RH (%) 21.9 27.4 25.5 24.2 16.3 -- 1. Ambient inside chamber -- -- -- 52.3 49.9 -- 3. Transformer T200 (bobbin) 52.9 53.5 43.3 71.3 69.1 130 4. Transformer T200 (windings) 70.4 70.5 52.3 86.1 83.7 130 5. Transformer T201 (bobbin) 67.9 68.0 52.0 80.9 78.6 130 6. Transformer T201 (windings) 72.0 70.7 51.4 84.4 82.0 130 7. PWB near T201 82.4 78.4 53.6 82.4 79.5 130 Flatpack2 1800W 48V Transf

ormer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 10 A, 1871 W, Output Condition: 47.7 Vdc, 35.1 A

Transformer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 9.0 A, 1685 W, Output Condition: 48.3 Vdc, 31.1 A

Transformer T200 and T201 version 5: Input Condition: 187.3 Vac, 50 Hz, 7.6 A, 1411 W, Output Condition: 48.1 Vdc, 26.4 A

Transformer T200 and T201 version 5: Input Condition: 91 Vac, 50 Hz, 6.4 A, 580 W, Output Condition: 48.5 Vdc, 10.4 A

Transformer T200 and T201 version 5: Input Condition: 264 Vac, 50 Hz, 5.5 A, 1452 W, Output Condition:48 Vdc, 27.5 A

--

Page 226: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 58 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Ambient (t2) 24.8 24.2 24.6 24.7 24.8 -- Humidity (2), RH (%) 16.8 18.7 17.5 17.1 16.8 -- 1. Ambient (Inside chamber) 52.0 59.7 74.8 74.4 74.4 -- 3. Transformer T200 (bobbin) 70.7 75.4 87.0 78.6 87.0 130 4. Transformer T200 (windings) 85.1 87.4 96.1 82.6 96.3 130 5. Transformer T201 (bobbin) 80.2 84.0 94.8 81.7 95.0 130 6. Transformer T201 (windings) 84.2 88.0 96.0 81.1 96.1 130 7. PWB near T201 81.4 84.2 93.7 78.6 90.7 130 Flatpack2 1800W 48V Transf

ormer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 10 A, 1871 W, Output Condition: 47.7 Vdc, 35.1 A

Transformer T200 and T201 version 5: Input Condition: 187 Vac, 50 Hz, 9.0 A, 1685 W, Output Condition: 48.3 Vdc, 31.1 A

Transformer T200 and T201 version 5: Input Condition: 187.3 Vac, 50 Hz, 7.6 A, 1411 W, Output Condition: 48.1 Vdc, 26.4 A

Transformer T200 and T201 version 5: Input Condition: 91 Vac, 50 Hz, 6.4 A, 580 W, Output Condition: 48.5 Vdc, 10.4 A

Transformer T200 and T201 version 5: Input Condition:264 Vac, 50 Hz, 5.5 A, 1452 W, Output Condition:48 Vdc, 27.5 A

--

Ambient (t2) 24.8 24.2 24.6 24.7 24.8 - Humidity (2), RH (%) 16.8 18.7 17.5 17.1 16.8 - 1. Ambient (Inside chamber) 52.0 59.7 74.8 74.4 74.4 - 3. Transformer T200 (bobbin) 70.7 75.4 87.0 78.6 87.0 130 4. Transformer T200 (windings) 85.1 87.4 96.1 82.6 96.3 130 5. Transformer T201 (bobbin) 80.2 84.0 94.8 81.7 95.0 130 6. Transformer T201 (windings) 84.2 88.0 96.0 81.1 96.1 130 7. PWB near T201 81.4 84.2 93.7 78.6 90.7 130 Flatpack2 1800W 48V Transf

ormer T200 and T201 version 5:

Transformer T200 and T201 version 5:

-- -- -- --

Page 227: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 59 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Input Condition: 264 Vac, 50 Hz, 7.4 A, 1931 W, Output Condition: 47.9 Vdc, 36.1 A

Input Condition: 86.1 V, 50 Hz, 8.2 A, 706 W, Output Condition: 47.6 Vdc, 12.1 A

Ambient (t2) 25.3 25.2 -- -- -- - Humidity (2), RH (%) 15.9 19.2 -- -- -- - 1. Ambient (Inside chamber) 49.4 46.4 -- -- -- - 3. Transformer T200 (bobbin) 68.3 52.2 -- -- -- 130 4. Transformer T200 (windings) 81.9 56.8 -- -- -- 130 5. Transformer T201 (bobbin) 78.8 55.5 -- -- -- 130 6. Transformer T201 (windings) 82.3 55.1 -- -- -- 130 7. PWB near T201 74.4 52.6 -- -- -- 130 Flatpack2 1800W 48V Transf

ormer T200 and T201 version 5: Input Condition: 187.7 V, 50 Hz, 3.3 A, 610 W, Output Condition: 11.5 Vdc,

Transformer T200 and T201 version 5: Input Condition: 189.6 V, 50 Hz, 0.9 A, 192 W, Output Condition (S/C): 0.2 Vdc, 36.4 A

Transformer T200 and T201 version 5: Input Condition: 187 V, 50 Hz, 10.5 A, 1050 W, Output Condition: 47.9 Vdc, 35.8 A (NTC10

Transformer T200 and T201 version 5: Input Condition: 187.9 V, 50 Hz, 10.5 A, 1966 W, Output Condition: 48.6 Vdc, 36.4 A (short-

-- --

Page 228: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 60 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

37.5 A

0 SC on the small card)

circuit of NTC 200)

Ambient (t2) 24.3 24.5 25.3 -- -- Humidity (2), RH (%) 20.4 20.2 20.6 -- -- 1. Ambient (Inside chamber) 48.8 47.3 44.3 23.8 -- -- 3. Transformer T200 (bobbin) 67.0 64.4 75.0 68.9 -- 190 4. Transformer T200 (windings) 80.5 77.4 86.9 76.5 -- 190 5. Transformer T201 (bobbin) 77.6 74.6 85.6 76.3 -- 190 6. Transformer T201 (windings) 84.4 81.7 88.8 92.2 -- 190 7. PWB near T201 75.6 73.3 57.9 93.0 -- -- Flatpack2 2000W 48V Input

Condition : 85 V, 50 Hz, 11.4A, 966W, duration 7 h, 48min ; Output Condition : 52.3 Vdc, 16.2 A

Input Condition : 100 V, 50 Hz, 11.5A, 1118W, duration 7 h, 48min ; Output Condition : 51.9 Vdc, 18.8 A

Input Condition : 185 V, 50 Hz, 11.7A, 2183W, duration 2 h, 28min ; Output Condition : 52.7 Vdc, 37.3 A

Input Condition : 230 V, 50 Hz, 9.4A, 2155W, duration 1 h, 4min ; Output Condition : 52.7 Vdc, 37.3 A

Input Condition : 250 V, 50 Hz, 8.7A, 2178W, duration 20min ; Output Condition : 53.1 Vdc, 37.7 A

--

Con100 housing 62.9 63.9 71.4 66.8 65.5 -- C100 67.8 68.5 73.8 66.8 65.0 105 L100 winding 78.0 78.9 84.1 72.4 69.4 155 C101 69.4 70.0 73.7 65.7 63.7 105 L101 80.5 81.4 86.0 73.0 69.8 155 F100 71.4 72.1 75.6 66.3 64.0 - T202 core 56.5 56.6 56.8 56.6 56.6 90 C102 60.9 61.3 63.6 59.3 58.2 105 L102 82.7 84.5 92.5 77.3 73.4 155 PWB near CON100 68.8 69.4 73.7 67.4 65.8 130 PWB near DB100 75.5 76.3 80.8 73.2 71.1 130 C200 top 56.9 57.3 59.7 57.1 56.5 105

Page 229: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 61 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

C113 top 50.5 50.8 52.5 51.6 51.3 105 L200 core 53.9 55.4 67.4 67.0 66.9 155 L200 coil 60.3 63.6 90.0 89.6 89.6 155 T202 coil 52.8 52.8 52.6 52.4 52.3 90 T200 coil 59.4 61.7 83.7 83.5 83.7 130 T200 core 61.7 63.5 79.4 78.8 78.8 130 T201 coil 63.6 66.2 91.2 90.6 90.6 130 T201 core 62.1 64.1 83.7 83.0 82.9 130 PWB near D207 62.4 65.5 91.7 91.1 91.1 130 C213 top 56.6 58.0 70.0 69.1 68.9 105 T100 core/coil 54.3 54.7 56.6 56.5 56.4 90 L202 winding 58.6 60.8 82.0 81.2 81.0 155 PWB near L202 60.5 62.5 81.0 80.1 79.9 130 CON100 housing SELV 58.5 60.9 82.4 81.3 81.2 -- Heat sink left 63.3 66.1 85.0 84.0 83.9 -- Heat sink right 71.0 72.0 77.9 72.6 71.2 -- Front bezel 46.2 46.3 45.5 45.5 45.5 95 T101 core/coil 51.0 51.3 52.8 52.8 52.7 90 Metal chassis top 58.9 59.4 64.2 61.8 61.0 -- Ambient 45.0 44.8 43.2 43.9 44.1 -- Flatpack2 2000W 48V Input

Condition : 275 V. 50 Hz. 7.8A. 2171W. duration 16 h. 39min ; Output Condition : 53.1 Vdc. 37.6 A

Input Condition : 185 V. 50 Hz. 7.5A. 1389W. duration 53min ; Output Condition : 43.8 Vdc. 28.7 A

-- -- -- --

Con100 housing 64.5 91.8 -- -- -- -- C100 63.3 91.8 -- -- -- 105 L100 winding 66.5 95.7 -- -- -- 155 C101 61.8 91.3 -- -- -- 105 L101 66.6 96.5 -- -- -- 155

Page 230: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 62 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

F100 61.9 91.8 -- -- -- - T202 core 56.5 83.0 -- -- -- 90 C102 57.1 86.8 -- -- -- 105 L102 69.4 99.4 -- -- -- 155 PWB near CON100 64.0 92.3 -- -- -- 130 PWB near DB100 68.9 96.7 -- -- -- 130 C200 top 55.9 85.2 -- -- -- 105 C113 top 51.1 80.7 -- -- -- 105 L200 core 67.2 90.7 -- -- -- 155 L200 coil 89.9 105.7 -- -- -- 155 T202 coil 52.3 80.1 -- -- -- 90 T200 coil 83.8 101.6 -- -- -- 130 T200 core 78.8 99.3 -- -- -- 130 T201 coil 90.6 106.4 -- -- -- 130 T201 core 83.1 101.7 -- -- -- 130 PWB near D207 91.0 108.1 -- -- -- 130 C213 top 68.9 93.3 -- -- -- 105 T100 core/coil 56.5 85.4 -- -- -- 90 L202 winding 80.9 100.6 -- -- -- 155 PWB near L202 79.7 100.2 -- -- -- 130 CON100 housing SELV 80.8 100.5 -- -- -- -- Heat sink left 83.7 103.9 -- -- -- -- Heat sink right 69.7 95.9 -- -- -- -- Front bezel 45.4 76.0 -- -- -- 95 T101 core/coil 53.0 82.1 -- -- -- 90 Metal chassis top 60.5 88.0 -- -- -- -- Ambient 43.6 74.8 -- -- -- -- Flatpack2 2000W 48V Input

Condition : 186 V. 50 Hz. 0.8A. 128W. duration 53min ; Output Condition : S-c. 0.6Vdc.

Input Condition : 190 V. 50 Hz. 8.5A. 1606W. duration 1 h. 45min ; Output Condition : Blocked ventilation.47.0 Vdc. 30.8 A

Input Condition : 190 V. 50 Hz. 8.5A. 1606W. duration 13min ; Output Condition : Blocked ventilation.41.5 Vdc. 30.8 A

Input Condition : 191 V. 50 Hz. 6.9A. 1309W. duration 1h. 43min ; Output Condition : NTC200 dis.. 40.8Vdc. 28.9 A

-- --

Page 231: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 63 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

29.7 A

Con100 housing 87.2 87.5 89.2 91.2 -- -- C100 84.2 90.5 86.3 90.6 -- -- L100 winding 83.6 115.8 104.4 93.8 -- -- C101 83.1 115.0 94.5 90.1 -- -- L101 83.6 130.5 108.2 94.4 -- -- F100 83.2 121.0 108.4 90.3 -- -- T202 core 85.6 81.5 80.2 83.2 -- -- C102 83.1 110.7 91.8 86.3 -- -- L102 86.0 142.3 116.2 97.1 -- -- PWB near CON100 82.9 92.0 91.8 91.1 -- -- PWB near DB100 83.6 108.0 102.9 95.2 -- -- C200 top 82.9 93.2 81.2 85.1 -- -- C113 top 80.4 79.6 73.7 81.5 -- -- L200 core 109.9 101.5 90.8 92.2 -- -- L200 coil 127.6 112.3 106.9 107.3 -- -- T202 coil 81.1 77.7 78.1 80.4 -- -- T200 coil 101.6 124.6 122.4 97.5 -- 190 T200 core 93.0 132.0 113.6 97.1 -- 190 T201 coil 103.7 140.7 122.4 107.7 -- 190 T201 core 98.2 131.7 115.8 101.6 -- 190 PWB near D207 108.6 119.8 118.5 107.8 -- -- C213 top 92.4 107.8 93.3 94.0 -- -- T100 core/coil 91.8 85.3 89.9 86.1 -- -- L202 winding 100.1 116.4 111.2 101.0 -- -- PWB near L202 98.0 116.6 109.6 100.1 -- -- CON100 housing SELV 99.9 93.0 101.6 100.3 -- -- Heat sink left 101.6 102.7 115.1 103.3 -- -- Heat sink right 84.2 97.4 102.0 94.8 -- -- Front bezel 75.9 57.2 74.3 76.5 -- -- T101 core/coil 85.8 80.6 87.3 82.6 -- -- Metal chassis top 84.3 82.7 91.3 83.3 -- -- Ambient 75.1 44.9 72.3 75.4 -- -- Flatpack2 2000W 48V Input

Condition : 190 V. 50 Hz. 10.5A. 1990W. duration 1h. 43min

Input Condition : 187 V. 50 Hz. 7.1A. 1318W. duration 1h. 41min ; Output Condition :

-- -- -- --

Page 232: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 64 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

; Output Condition : NTC100 dis. on main PCB. 50.1Vdc. 35.2A

NTC100 dis. on internal PCB. 40.8Vdc. 29.1A

Con100 housing 100.7 91.8 -- -- -- -- C100 101.3 91.2 -- -- -- -- L100 winding 110.3 94.5 -- -- -- -- C101 104.1 90.7 -- -- -- -- L101 112.1 95.1 -- -- -- -- F100 105.4 90.5 -- -- -- -- T202 core 86.3 83.3 -- -- -- -- C102 97.7 86.9 -- -- -- -- L102 118.6 97.8 -- -- -- -- PWB near CON100 101.2 91.6 -- -- -- -- PWB near DB100 105.8 95.6 -- -- -- -- C200 top 92.6 84.9 -- -- -- -- C113 top 85.6 81.4 -- -- -- -- L200 core 100.4 92.9 -- -- -- -- L200 coil 113.6 108.6 -- -- -- -- T202 coil 83.1 80.6 -- -- -- 190 T200 coil 114.2 98.3 -- -- -- 190 T200 core 114.8 99.8 -- -- -- 190 T201 coil 125.3 107.7 -- -- -- 190 T201 core 116.4 103.0 -- -- -- 190 PWB near D207 118.3 111.8 -- -- -- -- C213 top 103.2 94.6 -- -- -- -- T100 core/coil 89.2 86.2 -- -- -- -- L202 winding 111.8 102.3 -- -- -- -- PWB near L202 110.7 101.5 -- -- -- -- CON100 housing SELV 108.0 102.0 -- -- -- -- Heat sink left 116.6 112.7 -- -- -- -- Heat sink right 103.0 94.8 -- -- -- -- Front bezel 76.9 76.6 -- -- -- -- T101 core/coil 85.9 82.9 -- -- -- -- Metal chassis top 90.5 82.3 -- -- -- -- Ambient 75.7 75.5 -- -- -- --

Page 233: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 65 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

temperature T of winding: R1 (Ω) R2 ( Ω) T (°C) allowed Tmax (°C)

insulation class

supplementary information:

4.5.2 TABLE: ball pressure test of thermoplastics Pass allowed impression diameter (mm)........................ : 2 mm —

part test temperature (°C) impression diameter (mm)

Fuse holder, (1 mm thick) (Ashadi Glass ) 135 1.85 Fuse holder (1 mm thick) (Chevron Philips) 135 0.9 supplementary information:

4.7 TABLE: resistance to fire N/A

part manufacturer of material type of material thickness(mm) flammability class

supplementary information: See table 1.5.1

5.2 TABLE: electric strength tests, impulse tests and voltage surge tests Pass

test voltage applied between: test voltage (V) a.c./d.c.

breakdown Yes / No

Flatpack2 1800W 48V - - Primary -SELV 4243 Vdc No Primary - Earth 2121 Vdc No T200/T201: One layer of insulation 4243 Vdc No BobbinT202: 4243 Vdc No Insulation between components and heat sink 2121 Vdc No Insulation between chassis and PWB 2121 Vdc No Flatpack2 2000W 48V - - Primary -SELV 4250 Vdc No Primary - Earth 2400 Vdc No T200/T201: One layer of insulation 4250 Vdc No BobbinT202: 4250 Vdc No

Page 234: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 66 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Insulation between components and heat sink 2400 Vdc No Insulation between chassis and PWB 2400 Vdc No All models - - Insulation Formex GK-5BK 5000 Vdc* No Insulation Formex GK-10 5000 Vdc* No Insulation Formex GK-17 5000 Vdc* No supplementary information: There were no indications of break down. *) Formex insulation is used as an alternative insulation between PWB and chassis in Flatpac2 power supplies, but was tested also to comply with Reinforced insulation.

5.3 TABLE: fault condition tests Pass ambient temperature (°C) ....................................... : See below — model/type of power supply.................................... : See below — manufacturer of power supply ................................ : Eltek Energy A/S — rated markings of power supply ............................. : 1) 1800 W version: Input: 230

Vac, 45-66 Hz, 11.0 Amax Output: 53.5 Vdc, 33.6 A 2) 2000 W version: Input: 100 - 250Vac, 45-66 Hz, 12.5 Amax Output: 53.5 Vdc, 37.4 A

component No.

fault test voltage (V)

test time fuse No.

fuse current (A)

result

Flatpack2 1800W 48V

- - - - - -

PSU Blocked ventilations

- - F100, F101

- See heating test results for details. No hazard.

NTC 200 NTC 200 (SC) - - F100, F101

- See heating test results for details. No hazard.

NTC 100 on internal PWB

NTC 100 (SC) - - F100, F101

- See heating test results for details. No hazard.

NTC 100 on main PWB

NTC 100 (SC) - - F100, F101

- See heating test results for details. No hazard.

T200-T201 OL 189 10 min. F100, F101

12.13 The output was loaded with rated load (48 Vdc, 25.6 A), an external load was added

Page 235: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 67 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

right after the rectifying diode (D206)(Additional load: 5.89 A, 287 W) Unite operated for 10 min. then Switch transistors Q200 and Q201 broke (SC), F100 and F101 then operates. Maximum temperature measured on the transformer T201 (windings) was 95 °C No Hazard

T202 OL 232 - F100, F101

- An external load was added right after the rectifying diode (D204). The load was increased in small step to 0.61 A max. The maximum temperature measured on the core 41.0 °C If the external load was increased above 0.65 A, the transformer breaks. Ambient: 28.2 °C 18.5 %RH (Test performed 3 times total)

Fan (Sanyo Denki)

Locked rotor 12 V 7 hrs. - - The Fan was operating with its rotor locked for 7 hours. Maximum temperature measured on the housing was 75.2 °C

Fan (Sunon)

Locked rotor 12 V 7 hrs. - - The Fan was operating with its rotor locked for 7 hours. Maximum temperature measured on the housing was 39.1 °C

L201 SC 229.6 V - F100, F101

0.199 The output voltage increased to 54.04 Vdc No Hazard

D206 SC 229.7 - F100 3.2 Output voltage drops to 5

Page 236: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 68 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

, F101

Vdc. D201 blows.

D207 SC 229.6 - F100, F101

3.2 Output voltage drops to 5 Vdc. D201 blows.

Q200 Pin1 - Pin2 (SC) 230 1 sec F100, F101

- The unit broke No Hazard

C110 SC 230 1 sec F100, F101

- The unit powers down No hazard

DB100 Pin1 - Pin2 (SC) 230 1 sec. F100, F101

- Primary fuses F100 and F101 operated No hazrad

D202 Pin1 - Pin2 (SC) 230 1 sec F100, F101

- The unit powers down. No hazard

Q103 Pin1 - Pin2 (SC) 230 1 sec F100, F101

- Primary fuses F100 and F101 operated No hazard

C116 SC 230 1hour 15 mins

F100, F101

- The unit thermal down. Maximum temperature measured on T202 (core) was 81.5 °C

Flatpack2 2000W 48V

- - - - - -

PSU Blocked ventilation

250V - F100, F101

- See heating test results for details. Power supply shuts down output at 75°C ambient, due to high internal temperature. At ambient temperature at 45°C max. temperature is 140.7°C on T201. No hazard

NTC200 S-c 250V - F100, F101

- See heating test results for details. No hazard

NTC100 on internal PWB

S-c 250V - F100, F101

- See heating test results for details. No hazard

NTC100 on main PWB

S-c 250V - F100, F101

- See heating test results for details. No hazard

Flatpack2 2000W 24V

- - - - - -

Page 237: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 69 of 69 Report Reference # E177343-A19-UL-2

IEC 60950-1 Clause Requirement + Test Result - Remark Verdict

Underwriters Laboratories Inc.

ISO 200 S-c pin1-2 250V 10min F100, F101

9.3A – 0.3A Output shutdown. No hazard. Normal operation after fault is removed.

ISO 200 S-c pin3-4 250V 5min F100, F101

9.3A – 0.3A Output shutdown. No hazard. Power supply does not start after fault is removed.

ISO 201 S-c pin3-4 250V 10min F100, F101

9.2A – 0.3A Output shutdown. No hazard. Power supply does not start after fault is removed.

ISO 202 S-c pin1-2 250V 10min F100, F101

9.3A – 3.1A Output reduced to 14V, 45A. No hazard. Normal operation after fault is removed.

supplementary information:

Page 238: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 10 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Enclosure National Differences

(Total 10 Pages including this Cover Page)

USA / Canada

Page 239: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 10 Report Reference # E177343-A19-UL-2

IEC 60950-1

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

USA / Canada - Differences to IEC 60950-1:2001, First Edition 1.1 Equipment able to be installed in accordance with

the National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code, Part1, and when applicable, the National Electrical Safety Code, IEEE C2.

N/A

1.1.1 Equipment able to be installed in accordance with ANSI/NFPA 75 and NEC Art. 645 unless intended for use outside of computer room and provided with such instructions.

N/A

1.1.2 Equipment in wire-line communication facilities serving high-voltage electric power stations operating at greater than 1kV are excluded.

N/A

1.1.2 Special requirements apply to equipment intended for use outdoors.

N/A

1.4.14 For Pluggable Equipment Type A, the protection in the installation is assumed to be 20 A.

Equipment is for building-in Needs to be evaluated in the end product.

N/A

1.5.1 All IEC standards for components identified in Annex P.1 replaced by the relevant requirements of CSA and UL component standards in Annex P.1.

(see appended table 1.5.1) Pass

1.5.1 All IEC standards for components identified in Annex P.2 alternatively satisfied by the relevant requirements of CSA and UL component standards in Annex P.2.

(see appended table 1.5.1) Pass

1.5.5 Interconnecting cables acceptable for the application regarding voltage, current, temperature, flammability, mechanical serviceability and the like.

N/A

1.5.5 For other than limited power and TNV circuits, the type of output circuit identified for output connector.

N/A

1.5.5 External cable assemblies that exceed 3.05 m in length to be types specified in the NEC and CEC.

N/A

1.5.5 Detachable external interconnecting cables 3.05 m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable.

N/A

1.5.5 Building wiring and cable for use in ducts, plenums and other air handling space subject to special requirements and excluded from scope.

N/A

1.5.5 Telephone line and extension cords and the like comply with UL 1863 and CSA C22.2 No. 233.

N/A

Page 240: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 10 Report Reference # E177343-A19-UL-2

IEC 60950-1

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

1.6.1.2 Equipment intended for connection to a d.c. power (mains) distribution system is subject to special circuit classification requirements (e.g., TNV-2)

N/A

1.6.1.2 Earthing of d.c. powered equipment provided. N/A 1.7 Lamp replacement information indicated on

lampholder in operator access area. N/A

1.7.1 Special marking format for equipment intended for use on a supply system with an earthed neutral and more than one phase conductor.

N/A

1.7.1 Equipment voltage rating not higher than rating of the plug except under special conditions.

N/A

1.7.6 Special fuse replacement marking for operator accessible fuses.

N/A

1.7.7 Identification of terminal connection of the equipment earthing conductor.

N/A

1.7.7 Connectors and field wiring terminals for external Class 2 or Class 3 circuits provided with marking indicating minimum Class of wiring to be used.

N/A

1.7.7 Marking located adjacent to terminals and visible during wiring.

N/A

2.1.1 Screw shell of Edison-base lampholder tied to the neutral conductor.

N/A

2.1.1.1 Bare TNV conductive parts in the interior of equipment normally protected against contact by a cover intended for occasional removal are exempt provided instructions include directions for disconnection of TNV prior to removal of the cover.

N/A

2.3.1.b Other telecommunication signaling systems (e.g., message waiting) than described in 2.3.1(b) are subject to M.4.

N/A

2.3.1.b For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vp or 60 V d.c., the maximum current limit through a 2000 Ohm or greater resistor with loads disconnected is 7.1 mA peak or 30 mA d.c. under normal conditions.

N/A

2.3.1.b Limits for measurements across 5000 ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M.3.1.4.

N/A

2.3.2 Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications when

N/A

Page 241: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 10 Report Reference # E177343-A19-UL-2

IEC 60950-1

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

subjected to special construction requirements and routine testing.

2.3.2 In the event of a single fault, the limits of 2.2.3 apply to SELV circuits and accessible conductive parts.

N/A

2.5 Overcurrent protection device required for Class 2 and Class 3 limiting in accordance with the NEC, or for a Limited Power Source, not interchangeable with devices of higher ratings if operator replaceable.

N/A

2.6 Equipment having receptacles for output a.c. power connectors generated from an internal separately derived source have the earthed (grounded) circuit conductor suitably bonded to earth.

N/A

2.6.3.3 For Pluggable Equipment Type A, if neither a) or b) are applicable, the current rating of the circuit is taken as 20 A.

For building in - 20 A branch circuit assumed.

Pass

2.6.3.4 Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit.

N/A

2.6.3.4 Protective bonding conductors and their terminals of non-standard constructions (e.g. PWB traces) evaluated to limited short-circuit test of CSA C22.2 No.0.4.

Pass

2.6.4.1 Field wiring terminals for earthing conductors suitable for wire sizes (gauge) used in US and Canada.

N/A

2.7.1 Data for selection of special external branch circuit overcurrent devices marked on the equipment.

N/A

2.7.1 Standard supply outlets protected by overcurrent device in accordance with the NEC, and CEC, Part 1.

N/A

2.7.1 Overcurrent protection for individual transformers that distribute power to other units over branch circuit wiring.

N/A

2.7.1 Additional requirements for overcurrent protection apply to equipment provided with panelboards.

N/A

2.7.1 Non-motor-operated equipment requiring special overcurrent protective device marked with device rating.

N/A

2.10.5.4 Multi-layer winding wire subject to UL component wire requirements in addition to 2.10.5.4 and

Wire used in T100/T101 comply with UL component

Pass

Page 242: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 10 Report Reference # E177343-A19-UL-2

IEC 60950-1

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

Annex U. requirements and Annex U. 3.1.1 Permissible combinations of internal wiring/external

cable sizes for overcurrent and short circuit protection.

Pass

3.1.1 All interconnecting cables protected against overcurrent and short circuit.

N/A

3.2 Wiring methods permit connection of equipment to primary power supply in accordance with the NEC and CEC, Part 1.

N/A

3.2.1 Permitted use for flexible cords and plugs. N/A 3.2.1 Flexible cords provided with attachment plug rated

125% of equipment current rating. N/A

3.2.1 Any Class II equipment provided with 15 or 20 A standard supply outlets, Edison-base lampholders or single pole disconnect device provided with a polarized type attachment plug.

N/A

3.2.1.2 Equipment intended for connection to DC mains supply power systems complies with special wiring requirements (e.g., no permanent connection to supply by flexible cord).

N/A

3.2.1.2 Equipment with one pole of the DC mains supply connected to both the equipment mains input terminal and the main protective earthing terminal provided with special instructions and construction provisions for earthing

N/A

3.2.1.2 Equipment with means for connecting supply to earthing electrode conductor has no switches or protective devices between supply connection and earthing electrode connection.

N/A

3.2.1.2 Special markings and instructions for equipment with provisions to connect earthed conductor of a DC supply circuit to earthing conductor at the equipment.

N/A

3.2.1.2 Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the earthing conductor at the equipment.

N/A

3.2.1.2 Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard.

N/A

3.2.3 Permanently connected equipment has provision N/A

Page 243: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 10 Report Reference # E177343-A19-UL-2

IEC 60950-1

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

for connecting and securing a field wiring system (i.e. conduit, or leads etc.) per the NEC and CEC, Part 1.

3.2.3 Permanently connected equipment may have terminals or leads not smaller than No. 18 AWG (0.82 mm²) and not less than 152 mm in length for connection of field installed wiring.

N/A

3.2.3 If supply wires exceed 60 °C, marking indicates use of 75 °C or 90 °C wiring for supply connection as appropriate.

N/A

3.2.3 Equipment compatible with suitable trade sizes of conduits and cables.

N/A

3.2.5 Length of power supply cord limited to between 1.5 and 4.5 m unless shorter length used when intended for a special installation.

N/A

3.2.5 Conductors in power supply cords sized according to NEC and CEC, Part I.

N/A

3.2.5 Power supply cords and cord sets incorporate flexible cords suitable for the particular application.

N/A

3.2.6 Strain relief provided for non-detachable interconnecting cables not supplied by a limited power source.

N/A

3.2.9 Adequate wire bending space and volume of field wiring compartment required to properly make the field connections.

N/A

3.2.9 Equipment intended solely for installation in Restricted Access Locations using low voltage d.c. systems may not need provision for connecting and securing a field wiring system. A method of securing wiring or instructions provided to ensure the wiring is protected from abuse.

N/A

3.3 Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with 3.3.

N/A

3.3 Interconnection of units by LPS or Class 2 conductors may have field wiring connectors other than those specified in 3.3 if wiring is reliably separated.

N/A

3.3.1 Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means.

N/A

3.3.3 Wire binding screw terminal permitted for N/A

Page 244: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 7 of 10 Report Reference # E177343-A19-UL-2

IEC 60950-1

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

connection of No. 10 AWG (5.3 mm²) or smaller conductor if provided with upturned lugs, cupped washer or equivalent retention.

3.3.4 Terminals accept wire sizes (gauge) used in the U.S. and Canada.

N/A

3.3.4 Terminals accept current-carrying conductors rated 125% of the equipment current rating.

N/A

3.3.6 Field wiring terminals marked to indicate the material(s) of the conductor appropriate for the terminals used.

N/A

3.3.6 Connection of an aluminum conductor not permitted to terminal for equipment earthing conductor.

N/A

3.3.6 Field wiring connections made through the use of suitable pressure connectors (including set screw type), solder lugs or splices to flexible leads.

N/A

3.4.2 Separate motor control device(s) required for cord-connected equipment rated more than 12 A, or with motor rated more than 1/3 hp or more than 120 V.

N/A

3.4.8 Vertically mounted disconnect devices oriented so up position of handle is "on".

N/A

3.4.11 For computer-room applications, equipment with battery systems capable of supplying 750 VA for 5 min require battery disconnect means.

N/A

4.2.8.1 Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more.

N/A

4.2.9 Compartment housing high-pressure lamp marked to indicate risk of explosion.

N/A

4.3.2 Loading test for equipment with handle(s) used to support more than 9 kg tested at four times the weight of the unit.

Less than 9 kg. N/A

4.3.6 In addition to the IEC requirements, Direct Plug-in Equipment complies with UL 1310 or CSA 223 mechanical assembly requirements.

N/A

4.3.12 The maximum quantity of flammable liquid stored in equipment complies with ANSI/NFPA 30(Table NAE.6).

N/A

4.3.12 Equipment using replenishable liquids marked to indicate type of liquid to be used.

N/A

4.3.13.2 Equipment that produces x-radiation and does not comply with 4.3.12 under all conditions of servicing

N/A

Page 245: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 8 of 10 Report Reference # E177343-A19-UL-2

IEC 60950-1

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

marked to indicate the presence of radiation where readily visible.

4.3.13.5 Requirements contained in the applicable national codes and regulations apply to lasers (21 CFR 1040 and REDR C1370).

N/A

4.7 Automated information storage equipment intended to contain more than 0.76 mm³ of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system.

N/A

4.7.3.1 Equipment for use in environmental air space other than ducts or plenums provided with metal enclosure or with non-metallic enclosure having adequate fire-resistance and low smoke producing characteristics. Low smoke-producing characteristics evaluated according to UL 2043. Equipment for installation in space used for environmental air as described in Sec. 300-22(c) of the NEC provided with instructions indicating suitability for installation in such locations.

N/A

4.7.3.1 Flame spread rating for external surface of combustible material with exposed area greater than 0.93 m² or a single dimension greater than 1.8 m; 50 or less for computer room applications or 200 or less for other applications.

N/A

4.7.3.4 Wire marked "VW-1" or "FT-1" considered equivalent.

N/A

5.1.8.2 Special earthing provisions and instructions for equipment with high touch current due to telecommunication network connections.

N/A

5.1.8.3 Touch current due to ringing voltage for equipment containing telecommunication network leads.

N/A

5.3.6 Overloading of SELV connectors and printed wiring board receptacles accessible to the operator.

N/A

5.3.6 Tests interrupted by opening of a component repeated two additional times.

Test repeated two additional times

Pass

5.3.8.1 Test interrupted by opening of wire or trace subject to certain conditions.

N/A

6 Specialized instructions provided for telephones that may be connected to a telecommunications network.

N/A

6 Marking identifying function of telecommunication type connectors not used for connection to a telecommunication network.

N/A

Page 246: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 9 of 10 Report Reference # E177343-A19-UL-2

IEC 60950-1

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

6.2.1 Special requirements for enameled wiring used as electrical separation provided between parts connected to telecommunication network and telecommunication circuitry intentionally isolated from network.

N/A

6.2.1 Digital line termination equipment (e.g., NCTE) subject to separation requirements.

N/A

6.3 Equipment remotely powered over telecommunication wiring systems provided with specialized markings adjacent to the connection.

N/A

6.3 Overcurrent protection incorporated into equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable.

N/A

6.4 Additional requirements for equipment intended for connection to a telecommunication network using cable subject to overvoltage from power line failures (Fig. 6C).

N/A

6.4 Where 26 AWG line cord required by Fig. 6C, either the cord is provided with the equipment or described in the safety instructions.

N/A

6.5 Acoustic pressure from an ear piece less than 136 dBA for short duration disturbances, and less than 125 dBA for handsets, 118 dBA for headsets, and 121 dBA for insert earphones, for long duration disturbances.

N/A

7 Equipment associated with the cable distribution system may need to be subjected to applicable parts of Chapter 8 of the NEC.

N/A

H Ionizing radiation measurements made under single fault conditions in accordance with the requirements of the Code of Federal Regulations 21 CFR 1020 and the Canadian Radiation Emitting Devices Act, REDR C1370.

N/A

M.2 Continuous ringing signals evaluated to Method A subjected to special accessibility considerations.

N/A

M.4 Special requirements for message waiting and similar telecommunications signals.

N/A

NAC Equipment intended for use with a generic secondary protector marked with suitable instructions.

N/A

NAC Equipment intended for use with a specific primary or secondary protector marked with suitable

N/A

Page 247: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 10 of 10 Report Reference # E177343-A19-UL-2

IEC 60950-1

SubClause Difference + Test Result - Remark Verdict

Underwriters Laboratories Inc.

instructions.

Page 248: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Enclosure Photographs

Supplement Id Description 3-01 Overall Front View 3-02 Overall Rear View 3-03 Overall Front View with top cover removed (Flatpack 1800W 48V) 3-04 Internal View (Flatpack 1800W 48V) 3-05 Internal View (Flatpack 1800W 48V) 3-06 Internal View, from the rear side (Flatpack 1800W 48V) 3-07 Bottom View - Bottom cover removed (Flatpack 1800W 48V) 3-08 Bottom View - Main Earth Trace (Flatpack 1800W 48V) 3-09 Overall Front View with top cover removed Flatpack (Flatpack 2000W 48V) 3-10 Internal view of capacitors (Flatpack 2000W 48V) 3-11 Internal view of fuses (Flatpack 2000W 48V) 3-12 Bottom View - Bottom cover removed (Flatpack 2000W 48V) 3-13 Bottom View - Main Earth Trace (Flatpack 2000W 48V)

Page 249: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-01

Page 250: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-02

Page 251: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-03

Page 252: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-04

Page 253: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-05

Page 254: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 7 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-06

Page 255: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 8 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-07

Page 256: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 9 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-08

Page 257: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 10 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-09

Page 258: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 11 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-10

Page 259: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 12 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-11

Page 260: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 13 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-12

Page 261: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 14 of 14 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Photographs ID 3-13

Page 262: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Enclosure Diagrams

Supplement Id Description 4-01 Main transformer T200/T201 4-02 Input choke L100/L101 4-03 Inductor L102 4-04 Inductor L200 4-05 Transformer T100/T101 4-06 Transformer T202 4-07 DC Common mode Choke L202 4-08 Top Cover, Bottom Cover and left/right Heat Sink 4-09 Inductor L103 (2000W version) 4-10 Transformer T100/T101 4-11 Inductor L200 (2000 W module)

Page 263: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-01

Page 264: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-01

Page 265: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-01

Page 266: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-01

Page 267: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-01

Page 268: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 7 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-02

Page 269: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 8 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-02

Page 270: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 9 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-02

Page 271: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 10 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-02

Page 272: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 11 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-02

Page 273: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 12 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-02

Page 274: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 13 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 275: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 14 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 276: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 15 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 277: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 16 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 278: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 17 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-03

Page 279: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 18 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Page 280: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 19 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Page 281: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 20 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-04

Page 282: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 21 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Page 283: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 22 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Page 284: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 23 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-05

Page 285: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 24 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Page 286: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 25 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Page 287: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 26 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Page 288: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 27 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Page 289: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 28 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-06

Page 290: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 29 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-07

Page 291: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 30 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-07

Page 292: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 31 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-07

Page 293: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 32 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-08

Page 294: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 33 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-08

Page 295: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 34 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-08

Page 296: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 35 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-08

Page 297: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 36 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-08

Page 298: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 37 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-08

Page 299: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 38 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-09

Page 300: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 39 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-10

Page 301: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 40 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-10

Page 302: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 41 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-10

Page 303: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 42 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-10

Page 304: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 43 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-10

Page 305: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 44 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-11

Page 306: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 45 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-11

Page 307: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 46 of 46 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Diagrams ID 4-11

Page 308: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Enclosure Schematics + PWB

Supplement Id Description 5-01 Component layout 5-02 Trace layout 5-04 Component layout 5-05 Tracelayout

Page 309: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-01

Page 310: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-02

Page 311: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 4 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-02

Page 312: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 5 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-02

Page 313: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 6 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-02

Page 314: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 7 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-04

Page 315: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 8 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-05

Page 316: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 9 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-05

Page 317: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 10 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-05

Page 318: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 11 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-05

Page 319: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 12 of 12 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Schematics ID 5-05

Page 320: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 3 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Enclosure Miscellaneous

Supplement Id Description 7-01 Representative Label for 1800W model 7-02 Representative Label for 2000W model

Page 321: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 3 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Misc ID 7-01

Page 322: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 3 of 3 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Misc ID 7-02

Page 323: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 1 of 2 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Enclosure Test Record

Description Test Record 1 Protective Earthing Trace Earth fault current test

Page 324: COVER PAGE FOR TEST REPORT - Linux · PDF file · 2014-07-22Flatpack2 A B C, Flatpack2 A B C BF Where ... " refers to additional information appended to the Test Report - "(see appended

Issue Date: 2006-03-13 Page 2 of 2 Report Reference # E177343-A19-UL-2

Underwriters Laboratories Inc.

Test Record No. 1

Testing of Flatpack2 A B C (2000 W version) was not considered necessary based upon previous evaluation under CB Scheme. The CB Scheme Test Certificate Ref no. DK-9630 and Report Ref. No. E177343-A19-CB-3 dated 2006-03-09 were prepared by Rolf Bårnes and Jan J. Jensen. Except for Protective Earthing Trace Earth fault current test. The following tests were conducted: Test Comments Maximum Output Voltage, Current, and Volt-Ampere Measurement (1.2.2.1)

Performed under CB SMT

Input: Single-Phase (1.6.2) Performed under CB SMT SELV Reliability (2.2.2, 2.2.3, 2.2.4) Performed under CB SMT Earthing I (2.6.3.4, 2.6.1) Performed under CB SMT Determination of Working Voltage; Voltage Measurement (2.10.2) Performed under CB SMT Internal Spacings Push (2.10.3, 4.2.2, 4.2.3) Performed under CB SMT Knob Pull/Handle Loading (4.3.2) Performed under CB SMT Heating (4.5.1, 1.4.12, 1.4.13) Performed under CB SMT Touch Current (Single-Phase/ Polyphase; TN/TT System) (5.1, Annex D) Performed under CB SMT Electric Strength (5.2.2) Performed under CB SMT Component Failure (5.3.1, 5.3.4, 5.3.6) Performed under CB SMT Abnormal Operation (5.3.1 - 5.3.8.2) Performed under CB SMT Transformer Abnormal Operation (5.3.3, 5.3.6b, Annex C.1) Power Supply Output Short-Circuit/Overload (5.3.6) Performed under CB SMT

Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard.


Recommended