    Extract from the onlinecatalog

    FL SWITCH SF 4TX/3FX STOrder No.: 2832603

    http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832603

    Ethernet switch, 4 TP RJ45 ports, 3 FO ports, 100 Mbps full duplexin ST-D format, automatic detection of data transmission rate of 10 or 100 mbps (RJ45), auto crossing function

    Commercial data

    EAN 4046356044097

    Pack 1 pcs.

    Customs tariff 85176200

    http://www.download.phoenixcontact.comPlease note that the data givenhere has been taken from theonline catalog. For comprehensiveinformation and data, please refer to the user documentation. The

    General Terms and Conditions of

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    2/26

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    3/26

    FL SWITCH SF 4TX/3FX ST Order No.: 2832603http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832603

    Conformity with EMC directives

    Developed in acc. with standard IEC 61000-6.2

    Test standard IEC 61000-4-2 (ESD)

    Test result Criterion B

    Test standard IEC 61000-4-3 (immunity to radiated interference)

    Test result Criterion A

    Test standard IEC 61000-4-4 (burst)

    Test result Criterion A

    Test standard IEC 61000-4-5 (surge)

    Test result Criterion A

    Test standard IEC 61000-4-6 (immunity to conducted interference)

    Test result Criterion A

    Test standard IEC 61000-4-8 (immunity to magnetic fields)

    Test result Criterion A

    Test standard EN 55022 (emitted interference)

    Test result Criterion A

    Certificates / Approvals

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    4/26

    FL SWITCH SF 4TX/3FX ST Order No.: 2832603http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832603

    2832580 FL CAT5 PATCH 5,0 Patch cable, CAT5, assembled, 5.0 m

    2832616 FL CAT5 PATCH 7,5 Patch cable, CAT5, assembled, 7.5 m

    General

    0800886 E/NS 35 N End bracket, width: 9.5 mm, color: gray

    2832506 FL PBX 6TX/4FX Patch box with six RJ45 and four FO network connections

    2832496 FL PBX 8TX Patch box with eight RJ45 network connections

    2832991 FL RJ45 PROTECT CAP Dust protection caps for RJ45 female connector

    2832865 FL SEC PAC 4TX Layer1 security elements for four RJ45 network connections for use with patch boxes and panels

    Plug/Adapter

    2744571 FL PLUG RJ45 GN/2 RJ45 connector, shielded, with bend protection sleeve, 2 pieces,

    green for crossed cables, for assembly on site. For connectionsthat are crossed, it is recommended that the connector set withgreen bend protection sleeves is used.

    2744856 FL PLUG RJ45 GR/2 RJ45 connector, shielded, with bend protection sleeve, 2 pieces,gray for straight cables, for assembly on site. For connections thatare not crossed, it is recommended that you use the connector setwith gray bend protection sleeve.

    Software

    2832166 FL SNMP OPC SERVER SNMP OPC ser er German and English for monitoring and

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    5/26

    FL SWITCH SF 4TX/3FX ST Order No.: 2832603http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832603

    Drawings

    Approval logo (Ex area)

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    6/26

    FL SWITCH SF 4TX/3FX ST Order No.: 2832603http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832603

    Address

    PHOENIX CONTACT GmbH & Co. KGFlachsmarktstr. 832825 Blomberg,GermanyPhone +49 5235 3 00Fax +49 5235 3 41200http://www.phoenixcontact.de

    2009 Phoenix ContactTechnical modifications reserved;

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    7/26

    Extract from the onlinecatalog

    FL SWITCH SF 6TX/2FX STOrder No.: 2832674

    http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832674

    Ethernet switch, 6 TP RJ45 ports, 2 FO ports, 100 mbps full duplexin ST-D format, automatic detection of data transmission rate of 10 or 100 mbps (RJ45), autocrossing function,

    Commercial data

    EAN 4046356044134

    Pack 1 pcs.

    Customs tariff 85176200

    http://www.download.phoenixcontact.comPlease note that the data givenhere has been taken from theonline catalog. For comprehensiveinformation and data, please refer to the user documentation. The

    General Terms and Conditions of

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    8/26

    FL SWITCH SF 6TX/2FX ST Order No.: 2832674http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832674

    Type of connection ST format

    Transmission speed 100 MBit/s (ST, full duplex)

    Transmission length 6400 m (glass fiber with F-G 50/125 0.7 dB/km F1200)

    Interface Potential-free signaling contact

    Type of connection Plug-in/screw connection via COMBICON

    Function

    Basic functionality Unmanaged switch / autonegotiation, complies with IEEE 802.3,store and forward switching mode

    Supported browsers Internet Explorer 5.5 or higher

    Status and diagnostics displays LEDs: U S1 , U S2 (redundant voltage supply), link and activity per port

    Network extension parametersCascading depth Network, line and star structure: any

    Maximum conductor length ((twisted pair) 100 m

    Supply voltage

    Supply voltage 24 V DC

    Residual ripple 3.6 V PP (within the permitted voltage range)

    Range of supply voltages 18 5 V DC 30 2 V DC

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    9/26

    FL SWITCH SF 6TX/2FX ST Order No.: 2832674http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832674

    Conformity with EMC directives

    Developed in acc. with standard IEC 61000-6.2

    Test standard IEC 61000-4-2 (ESD)

    Test result Criterion B

    Test standard IEC 61000-4-3 (immunity to radiated interference)

    Test result Criterion A

    Test standard IEC 61000-4-4 (burst)

    Test result Criterion A

    Test standard IEC 61000-4-5 (surge)

    Test result Criterion A

    Test standard IEC 61000-4-6 (immunity to conducted interference)

    Test result Criterion A

    Test standard IEC 61000-4-8 (immunity to magnetic fields)

    Test result Criterion A

    Test standard EN 55022 (emitted interference)

    Test result Criterion A

    Certificates / Approvals

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    10/26

    FL SWITCH SF 6TX/2FX ST Order No.: 2832674http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832674

    2832580 FL CAT5 PATCH 5,0 Patch cable, CAT5, assembled, 5.0 m

    2832616 FL CAT5 PATCH 7,5 Patch cable, CAT5, assembled, 7.5 m

    General

    0800886 E/NS 35 N End bracket, width: 9.5 mm, color: gray

    2832506 FL PBX 6TX/4FX Patch box with six RJ45 and four FO network connections

    2832496 FL PBX 8TX Patch box with eight RJ45 network connections

    2832991 FL RJ45 PROTECT CAP Dust protection caps for RJ45 female connector

    2832865 FL SEC PAC 4TX Layer1 security elements for four RJ45 network connections for use with patch boxes and panels

    Plug/Adapter

    2744571 FL PLUG RJ45 GN/2 RJ45 connector, shielded, with bend protection sleeve, 2 pieces,

    green for crossed cables, for assembly on site. For connectionsthat are crossed, it is recommended that the connector set withgreen bend protection sleeves is used.

    2744856 FL PLUG RJ45 GR/2 RJ45 connector, shielded, with bend protection sleeve, 2 pieces,gray for straight cables, for assembly on site. For connections thatare not crossed, it is recommended that you use the connector setwith gray bend protection sleeve.

    Software

    2832166 FL SNMP OPC SERVER SNMP OPC ser er German and English for monitoring and

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    11/26

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    12/26

    FL SWITCH SF 6TX/2FX ST Order No.: 2832674http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832674

    Address

    PHOENIX CONTACT GmbH & Co. KGFlachsmarktstr. 832825 Blomberg,GermanyPhone +49 5235 3 00

    Fax +49 5235 3 41200http://www.phoenixcontact.de

    2009 Phoenix ContactTechnical modifications reserved;

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    13/26

    Extract from the onlinecatalog

    FL SWITCH SF 8TXOrder No.: 2832771

    http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832771

    Ethernet Switch, 8 TP RJ45 ports, automatic detection of data

    transmission rate of 10 or 100 Mbit/s (RJ45), autocrossing function

    Commercial data

    EAN 4017918952204

    Pack 1 pcs.

    Customs tariff 85176200

    Product notes

    WEEE/RoHS-compliant since:05/08/2008

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    14/26

    FL SWITCH SF 8TX Order No.: 2832771http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832771

    Transmission speed 10/100 MBit/s (RJ45)

    Transmission length 100 m (per segment)

    Signal LEDs Data receive, link status

    Interface Potential-free signaling contact

    Type of connection Plug-in/screw connection via COMBICON

    FunctionBasic functionality Unmanaged switch / autonegotiation, complies with IEEE 802.3,

    store and forward switching mode

    Status and diagnostics displays LEDs: U S1 , U S2 (redundant voltage supply), link and activity per port

    Network extension parameters

    Cascading depth Network, line and star structure: anyMaximum conductor length ((twisted pair) 100 m

    Supply voltage

    Supply voltage 24 V DC

    Residual ripple 3.6 V PP (within the permitted voltage range)

    Range of supply voltages 18.5 V DC ... 30.2 V DC

    Typical current consumption Typ 200 mA

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    15/26

    FL SWITCH SF 8TX Order No.: 2832771http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832771

    Mechanical tests

    Type of test Shock test in acc. with IEC 60068-2-27

    Test result Operation: 25 g, 11 ms duration, semi-sinusoidal shock impulse

    Conformity with EMC directives

    Developed in acc. with standard IEC 61000-6.2

    Test standard IEC 61000-4-2 (ESD)Test result Criterion B

    Test standard IEC 61000-4-3 (immunity to radiated interference)

    Test result Criterion A

    Test standard IEC 61000-4-4 (burst)

    Test result Criterion B

    Test standard IEC 61000-4-5 (surge)Test result Criterion B

    Test standard IEC 61000-4-6 (immunity to conducted interference)

    Test result Criterion A

    Test standard IEC 61000-4-8 (immunity to magnetic fields)

    Test result Criterion A

    Test standard EN 55022 (emitted interference)

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    16/26

    FL SWITCH SF 8TX Order No.: 2832771http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832771

    2744814 FL CAT5 HEAVY CAT5-SF/UTP cable (J-02YS(ST)C HP 2 x 2 x 24 AWG), heavy-duty installation cable, 2 x 2 x 0.22 mm, solid conductor, shielded,outer sheath: 7.8 mm diameter, inner sheath: 5.75 mm 0.15 mmdiameter

    Plug/Adapter

    2744571 FL PLUG RJ45 GN/2 RJ45 connector, shielded, with bend protection sleeve, 2 pieces,green for crossed cables, for assembly on site. For connectionsthat are crossed, it is recommended that the connector set withgreen bend protection sleeves is used.

    2744856 FL PLUG RJ45 GR/2 RJ45 connector, shielded, with bend protection sleeve, 2 pieces,gray for straight cables, for assembly on site. For connections thatare not crossed, it is recommended that you use the connector setwith gray bend protection sleeve.

    Tools

    2744869 FL CRIMPTOOL Crimping pliers, for assembling the RJ45 connectors FL PLUGRJ45..., for assembly on site

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    17/26

    FL SWITCH SF 8TX Order No.: 2832771http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832771

    Drawings

    Approval logo (Ex area)

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    18/26

    FL SWITCH SF 8TX Order No.: 2832771http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832771

    Address

    PHOENIX CONTACT GmbH & Co. KGFlachsmarktstr. 832825 Blomberg,GermanyPhone +49 5235 3 00

    Fax +49 5235 3 41200http://www.phoenixcontact.de

    2009 Phoenix ContactTechnical modifications reserved;

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    19/26

    01 COMMISSION 10.03.09

    D A T E

    :

    1 3

    .

    A p r

    i l

    2 0 0 6

    C A E

    :

    E P L A N

    5

    . 7 0

    . 3

    S P 1

    CON.NO.

    C -

    O

    5 7 0 E

    O B S E R V E

    P R O T E C T I O N

    M A R K

    A C C O R D I N G

    T O

    D I N

    3 4

    !

    10

    0

    REVI SI ON DATE

    ASG

    NAME

    1

    DATE

    COMM.

    CHECK

    STAND

    27.08.07

    A.Sengupta

    S.Suchanek

    16.04.09

    2

    ORIG. SUBST.

    3

    STEEL SLABCRANES 101/102/103CSA Brazil

    REPL.

    4

    THE POWER CONVERSIONCOMPANY

    5

    DESIGNATION:

    ETHERNET OVERVIEWTROLLEY

    E-HOUSE

    6

    COMMISSION-No.:

    K147008

    CIRCUIT DIAGRAM

    7

    D4.147008DRAWING.-No.:

    8

    =

    +

    A

    9

    SHEET

    FROM

    11 v.100Bl.

    12

    11

    801

    =F0+E1H1-A15.3

    =F0+E1H1/20.1 2 4 V

    2 3 0 V

    2 3 0 V

    WAGO 750-341

    =K+E1E30-A300

    =K+E1E30/18.1

    WAGO 750-461

    =K+E1E30-A306

    =K+E1E30/23.0

    WAGO 750-612

    =K+E1E30-A310

    =K+E1E30/25.1

    WAGO 750-405

    =K+E1E30-A321

    =K+E1E30/31.0

    WAGO 750-430

    =K+E1E30-A302

    =K+E1E30/19.0

    WAGO 750-461

    =K+E1E30-A307

    =K+E1E30/23.5

    WAGO 750-405

    =K+E1E30-A311

    =K+E1E30/26.0

    WAGO 750-405

    =K+E1E30-A322

    =K+E1E30/31.5

    WAGO 750-430

    =K+E1E30-A303

    =K+E1E30/20.0

    WAGO 750-461

    =K+E1E30-A308

    =K+E1E30/24.0

    WAGO 750-405

    =K+E1E30-A312

    =K+E1E30/26.5

    WAGO 750-405

    =K+E1E30-A323

    =K+E1E30/32.0

    WAGO 750-530

    =K+E1E30-A304

    =K+E1E30/21.0

    WAGO 750-405

    =K+E1E30-A313

    =K+E1E30/27.0

    WAGO 750-405

    =K+E1E30-A324

    =K+E1E30/32.5

    WAGO 750-466

    =K+E1E30-A329

    =K+E1E30/22.1

    WAGO 750-405

    =K+E1E30-A314

    =K+E1E30/27.5

    WAGO 750-405

    =K+E1E30-A325

    =K+E1E30/33.0

    WAGO 750-466

    =K+E1E30-A330

    =K+E1E30/22.6

    WAGO 750-405

    =K+E1E30-A315

    =K+E1E30/28.0

    WAGO 750-405

    =K+E1E30-A326

    =K+E1E30/33.5

    WAGO 750-405

    =K+E1E30-A316

    =K+E1E30/28.5

    WAGO 750-405

    =K+E1E30-A327

    =K+E1E30/34.0

    WAGO 750-405

    =K+E1E30-A317

    =K+E1E30/29.0

    WAGO 750-405

    =K+E1E30-A328

    =K+E1E30/34.5

    WAGO 750-405

    =K+E1E30-A318

    =K+E1E30/29.5

    WAGO 750-600

    =K+E1E30-A331

    =K+E1E30/41.1

    WAGO 750-405

    =K+E1E30-A319

    =K+E1E30/30.0

    WAGO 750-405

    =K+E1E30-A320

    =K+E1E30/30.5

    =K+E1E30-PANEL

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    20/26

    01 COMMISSION 10.03.09

    D A T E

    :

    1 3

    .

    A p r

    i l

    2 0 0 6

    C A E

    :

    E P L A N

    5

    . 7 0

    . 3

    S P 1

    CON.NO.

    C -

    O

    5 7 0 E

    O B S E R V E

    P R O T E C T I O N

    M A R K

    A C C O R D I N G

    T O

    D I N

    3 4

    !

    11

    0

    REVI SI ON DATE

    ASG

    NAME

    1

    DATE

    COMM.

    CHECK

    STAND

    27.08.07

    A.Sengupta

    S.Suchanek

    16.04.09

    2

    ORIG. SUBST.

    3

    STEEL SLABCRANES 101/102/103CSA Brazil

    REPL.

    4

    THE POWER CONVERSIONCOMPANY

    5

    DESIGNATION:

    ETHERNET OVERVIEWGANTRY WS

    E-HOUSE

    6

    COMMISSION-No.:

    K147008

    CIRCUIT DIAGRAM

    7

    D4.147008DRAWING.-No.:

    8

    =

    +

    A

    9

    SHEET

    FROM

    12 v.100Bl.

    13

    12

    801

    =F0+E1H1-A15.3

    =F0+E1H1/20.1

    GANTRY WATERSIDE

    2 4 V

    2 3 0 V

    2 3 0 V

    2 3 0 V

    WAGO 750-341

    =M+E1E41-A110

    =M+E1E41/20.0

    WAGO 750-461

    =M+E1E41-A121

    =M+E1E41/28.5

    WAGO 750-612

    =M+E1E41-A131

    =M+E1E41/32.5

    WAGO 750-405

    =M+E1E41-A142

    =M+E1E41/38.0

    WAGO 750-405

    =M+E1E41-A153

    =M+E1E41/43.5

    WAGO 750-430

    =M+E1E41-A111

    =M+E1E41/21.0

    WAGO 750-461

    =M+E1E41-A123

    =M+E1E41/29.0

    WAGO 750-405

    =M+E1E41-A132

    =M+E1E41/33.0

    WAGO 750-405

    =M+E1E41-A143

    =M+E1E41/38.5

    WAGO 750-600

    =M+E1E41-A154

    =M+E1E41/52.8

    WAGO 750-430

    =M+E1E41-A112

    =M+E1E41/22.0

    WAGO 750-461

    =M+E1E41-A124

    =M+E1E41/29.5

    WAGO 750-405

    =M+E1E41-A133

    =M+E1E41/33.5

    WAGO 750-405

    =M+E1E41-A144

    =M+E1E41/39.0

    WAGO 750-430

    =M+E1E41-A113

    =M+E1E41/23.0

    WAGO 750-461

    =M+E1E41-A125

    =M+E1E41/30.0

    WAGO 750-405

    =M+E1E41-A134

    =M+E1E41/34.0

    WAGO 750-405

    =M+E1E41-A145

    =M+E1E41/39.5

    WAGO 750-430

    =M+E1E41-A114

    =M+E1E41/24.0

    WAGO 750-461

    =M+E1E41-A126

    =M+E1E41/30.5

    WAGO 750-405

    =M+E1E41-A135

    =M+E1E41/34.5

    WAGO 750-405

    =M+E1E41-A146

    =M+E1E41/40.0

    WAGO 750-530

    =M+E1E41-A115

    =M+E1E41/25.0

    WAGO 750-461

    =M+E1E41-A127

    =M+E1E41/31.0

    WAGO 750-405

    =M+E1E41-A136

    =M+E1E41/35.0

    WAGO 750-405

    =M+E1E41-A147

    =M+E1E41/40.5

    WAGO 750-461

    =M+E1E41-A116

    =M+E1E41/26.0

    WAGO 750-461

    =M+E1E41-A128

    =M+E1E41/31.5

    WAGO 750-405

    =M+E1E41-A137

    =M+E1E41/35.5

    WAGO 750-405

    =M+E1E41-A148

    =M+E1E41/41.0

    WAGO 750-461

    =M+E1E41-A117

    =M+E1E41/26.5

    WAGO 750-405

    =M+E1E41-A138

    =M+E1E41/36.0

    WAGO 750-405

    =M+E1E41-A149

    =M+E1E41/41.5

    =F0+E1H1-A15.2

    =F0+E1H1/19.1

    WAGO 750-461

    =M+E1E41-A118

    =M+E1E41/27.0

    WAGO 750-405

    =M+E1E41-A139

    =M+E1E41/36.5

    WAGO 750-405

    =M+E1E41-A150

    =M+E1E41/42.0

    WAGO 750-461

    =M+E1E41-A119

    =M+E1E41/27.5

    WAGO 750-405

    =M+E1E41-A140

    =M+E1E41/37.0

    WAGO 750-405

    =M+E1E41-A151

    =M+E1E41/42.5

    =M+X1-1G11

    =M+E1E41/8.5

    =M+X6P1-DESK

    ABSOLUTEENCODER

    WAGO 750-461

    =M+E1E41-A120

    =M+E1E41/28.0

    WAGO 750-405

    =M+E1E41-A141

    =M+E1E41/37.5

    WAGO 750-405

    =M+E1E41-A152

    =M+E1E41/43.0

    =M+E1E41-PANEL

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    21/26

    01 COMMISSION 10.03.09

    D A T E

    :

    1 3

    .

    A p r

    i l

    2 0 0 6

    C A E

    :

    E P L A N

    5

    . 7 0

    . 3

    S P 1

    CON.NO.

    C -

    O

    5 7 0 E

    O B S E R V E

    P R O T E C T I O N

    M A R K

    A C C O R D I N G

    T O

    D I N

    3 4

    !

    12

    0

    REVI SI ON DATE

    ASG

    NAME

    1

    DATE

    COMM.

    CHECK

    STAND

    27.08.07

    A.Sengupta

    S.Suchanek

    16.04.09

    2

    ORIG. SUBST.

    3

    STEEL SLABCRANES 101/102/103CSA Brazil

    REPL.

    4

    THE POWER CONVERSIONCOMPANY

    5

    DESIGNATION:

    ETHERNET OVERVIEWGANTRY LS

    E-HOUSE

    6

    COMMISSION-No.:

    K147008

    CIRCUIT DIAGRAM

    7

    D4.147008DRAWING.-No.:

    8

    =

    +

    A

    9

    SHEET

    FROM

    13 v.100Bl.

    14

    13

    801

    =F0+E1H1-A15.3

    =F0+E1H1/20.1

    GANTRY LANDSIDE

    2 4 V

    2 3 0 V

    2 3 0 V

    2 3 0 V

    2 3 0 V

    WAGO 750-341

    =M+E1E42-A150

    =M+E1E42/20.0

    WAGO 750-461

    =M+E1E42-A157

    =M+E1E42/27.0

    WAGO 750-461

    =M+E1E42-A168

    =M+E1E42/32.5

    WAGO 750-612

    =M+E1E42-A170

    =M+E1E42/33.1

    WAGO 750-405

    =M+E1E42-A181

    =M+E1E42/39.0

    WAGO 750-405

    =M+E1E42-A192

    =M+E1E42/44.5

    WAGO 750-405

    =M+E1E42-A203

    =M+E1E42/50.0

    WAGO 750-600

    =M+E1E42-A214

    =M+E1E42/66.8

    WAGO 750-430

    =M+E1E42-A152

    =M+E1E42/21.0

    WAGO 750-461

    =M+E1E42-A158

    =M+E1E42/27.5

    WAGO 750-405

    =M+E1E42-A171

    =M+E1E42/34.0

    WAGO 750-405

    =M+E1E42-A182

    =M+E1E42/39.5

    WAGO 750-405

    =M+E1E42-A193

    =M+E1E42/45.0

    WAGO 750-405

    =M+E1E42-A204

    =M+E1E42/50.5

    WAGO 750-430

    =M+E1E42-A153

    =M+E1E42/22.0

    WAGO 750-461

    =M+E1E42-A159

    =M+E1E42/28.0

    WAGO 750-405

    =M+E1E42-A172

    =M+E1E42/34.5

    WAGO 750-405

    =M+E1E42-A183

    =M+E1E42/40.0

    WAGO 750-405

    =M+E1E42-A194

    =M+E1E42/45.5

    WAGO 750-509

    =M+E1E42-A205

    =M+E1E42/51.0

    WAGO 750-430

    =M+E1E42-A154

    =M+E1E42/23.0

    WAGO 750-461

    =M+E1E42-A160

    =M+E1E42/28.5

    WAGO 750-405

    =M+E1E42-A173

    =M+E1E42/35.0

    WAGO 750-405

    =M+E1E42-A184

    =M+E1E42/40.5

    WAGO 750-405

    =M+E1E42-A195

    =M+E1E42/46.1

    WAGO 750-509

    =M+E1E42-A206

    =M+E1E42/51.5

    WAGO 750-430

    =M+E1E42-A155

    =M+E1E42/24.0

    WAGO 750-461

    =M+E1E42-A161

    =M+E1E42/29.0

    WAGO 750-405

    =M+E1E42-A174

    =M+E1E42/35.5

    WAGO 750-405

    =M+E1E42-A185

    =M+E1E42/41.0

    WAGO 750-405

    =M+E1E42-A196

    =M+E1E42/46.5

    WAGO 750-509

    =M+E1E42-A207

    =M+E1E42/52.0

    WAGO 750-530

    =M+E1E42-A156

    =M+E1E42/25.0

    WAGO 750-461

    =M+E1E42-A162

    =M+E1E42/29.5

    WAGO 750-405

    =M+E1E42-A175

    =M+E1E42/36.0

    WAGO 750-405

    =M+E1E42-A186

    =M+E1E42/41.5

    WAGO 750-405

    =M+E1E42-A197

    =M+E1E42/47.0

    WAGO 750-509

    =M+E1E42-A208

    =M+E1E42/52.5

    WAGO 750-554

    =M+E1E42-A156.1

    =M+E1E42/26.1

    WAGO 750-461

    =M+E1E42-A163

    =M+E1E42/30.0

    WAGO 750-405

    =M+E1E42-A176

    =M+E1E42/36.5

    WAGO 750-405

    =M+E1E42-A187

    =M+E1E42/42.0

    WAGO 750-405

    =M+E1E42-A198

    =M+E1E42/47.5

    WAGO 750-509

    =M+E1E42-A209

    =M+E1E42/53.0

    WAGO 750-461

    =M+E1E42-A164

    =M+E1E42/30.5

    WAGO 750-405

    =M+E1E42-A177

    =M+E1E42/37.0

    WAGO 750-405

    =M+E1E42-A188

    =M+E1E42/42.5

    WAGO 750-405

    =M+E1E42-A199

    =M+E1E42/48.0

    WAGO 750-509

    =M+E1E42-A210

    =M+E1E42/53.5

    WAGO 750-461

    =M+E1E42-A165

    =M+E1E42/31.0

    WAGO 750-405

    =M+E1E42-A178

    =M+E1E42/37.5

    WAGO 750-405

    =M+E1E42-A189

    =M+E1E42/43.0

    WAGO 750-405

    =M+E1E42-A200

    =M+E1E42/48.5

    WAGO 750-509

    =M+E1E42-A211

    =M+E1E42/54.0

    WAGO 750-461

    =M+E1E42-A166

    =M+E1E42/31.5

    WAGO 750-405

    =M+E1E42-A179

    =M+E1E42/38.0

    WAGO 750-405

    =M+E1E42-A190

    =M+E1E42/43.5

    WAGO 750-405

    =M+E1E42-A201

    =M+E1E42/49.0

    WAGO 750-509

    =M+E1E42-A212

    =M+E1E42/54.5

    =M+E1E42-PANEL

    WAGO 750-461

    =M+E1E42-A167

    =M+E1E42/32.0

    WAGO 750-405

    =M+E1E42-A180

    =M+E1E42/38.5

    WAGO 750-405

    =M+E1E42-A191

    =M+E1E42/44.0

    WAGO 750-405

    =M+E1E42-A202

    =M+E1E42/49.5

    WAGO 750-509

    =M+E1E42-A213

    =M+E1E42/55.0

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    22/26

    01 COMMISSION 10.03.09

    D A T E

    :

    1 3

    .

    A p r

    i l

    2 0 0 6

    C A E

    :

    E P L A N

    5

    . 7 0

    . 3

    S P 1

    CON.NO.

    C -

    O

    5 7 0 E

    O B S E R V E

    P R O T E C T I O N

    M A R K

    A C C O R D I N G

    T O

    D I N

    3 4

    !

    13

    0

    REVI SI ON DATE

    ASG

    NAME

    1

    DATE

    COMM.

    CHECK

    STAND

    27.08.07

    A.Sengupta

    S.Suchanek

    16.04.09

    2

    ORIG. SUBST.

    3

    STEEL SLABCRANES 101/102/103CSA Brazil

    REPL.

    4

    THE POWER CONVERSIONCOMPANY

    5

    DESIGNATION:

    ETHERNET OVERVIEWBOOM

    E-HOUSE

    6

    COMMISSION-No.:

    K147008

    CIRCUIT DIAGRAM

    7

    D4.147008DRAWING.-No.:

    8

    =

    +

    A

    9

    SHEET

    FROM

    14 v.100Bl.

    15

    14

    801

    =F0+E1H1-A15.3

    =F0+E1H1/20.1

    2 3 0 V

    2 3 0 V

    2 3 0 V

    2 3 0 V

    WAGO 750-341

    =N+E1E51

    -A50=N+E1E51/28.0

    WAGO 750-530

    =N+E1E51

    -A61=N+E1E51/39.0

    WAGO 750-612

    =N+E1E51

    -A68=N+E1E51/46.5

    WAGO 750-405

    =N+E1E51

    -A78=N+E1E51/52.0

    WAGO 750-405

    =N+E1E51

    -A88=N+E1E51/57.0

    WAGO 750-405

    =N+E1E51

    -A99=N+E1E51/62.5

    WAGO 750-430

    =N+E1E51

    -A51=N+E1E51/29.0

    WAGO 750-554

    =N+E1E51-A61.1

    =N+E1E51/40.1

    WAGO 750-405

    =N+E1E51

    -A69=N+E1E51/47.0

    WAGO 750-405

    =N+E1E51

    -A79=N+E1E51/52.5

    WAGO 750-405

    =N+E1E51

    -A89=N+E1E51/57.5

    WAGO 750-509

    =N+E1E51-A100

    =N+E1E51/63.0

    WAGO 750-430

    =N+E1E51

    -A52=N+E1E51/30.0

    WAGO 750-461

    =N+E1E51

    -A62=N+E1E51/41.0

    WAGO 750-405

    =N+E1E51

    -A70=N+E1E51/47.5

    WAGO 750-405

    =N+E1E51

    -A80=N+E1E51/53.0

    WAGO 750-405

    =N+E1E51

    -A90=N+E1E51/58.0

    WAGO 750-509

    =N+E1E51-A101

    =N+E1E51/63.5

    WAGO 750-430

    =N+E1E51

    -A53=N+E1E51/31.0

    WAGO 750-461

    =N+E1E51

    -A63=N+E1E51/41.5

    WAGO 750-405

    =N+E1E51

    -A71=N+E1E51/48.5

    WAGO 750-405

    =N+E1E51

    -A81=N+E1E51/53.5

    WAGO 750-405

    =N+E1E51

    -A91=N+E1E51/58.5

    WAGO 750-509

    =N+E1E51-A102

    =N+E1E51/64.0

    WAGO 750-430

    =N+E1E51

    -A54=N+E1E51/32.0

    WAGO 750-461

    =N+E1E51

    -A64=N+E1E51/42.0

    WAGO 750-405

    =N+E1E51

    -A72=N+E1E51/49.0

    WAGO 750-405

    =N+E1E51

    -A82=N+E1E51/54.0

    WAGO 750-405

    =N+E1E51

    -A92=N+E1E51/59.0

    WAGO 750-509

    =N+E1E51-A103

    =N+E1E51/64.5

    =F0+E1H1-A15.2

    =F0+E1H1/19.1

    WAGO 750-430

    =N+E1E51

    -A55=N+E1E51/33.0

    WAGO 750-612

    =N+E1E51-A61.2

    =N+E1E51/42.5

    WAGO 750-405

    =N+E1E51

    -A73=N+E1E51/49.5

    WAGO 750-405

    =N+E1E51

    -A83=N+E1E51/54.5

    WAGO 750-405

    =N+E1E51

    -A93=N+E1E51/59.5

    WAGO 750-509

    =N+E1E51-A104

    =N+E1E51/65.0

    WAGO 750-430

    =N+E1E51

    -A56=N+E1E51/34.0

    WAGO 750-466

    =N+E1E51

    -A65=N+E1E51/43.3

    WAGO 750-405

    =N+E1E51

    -A74=N+E1E51/50.0

    WAGO 750-405

    =N+E1E51

    -A84=N+E1E51/55.0

    WAGO 750-405

    =N+E1E51

    -A94=N+E1E51/60.0

    WAGO 750-509

    =N+E1E51-A105

    =N+E1E51/65.5

    WAGO 750-430

    =N+E1E51

    -A57=N+E1E51/35.0

    WAGO 750-466

    =N+E1E51

    -A66=N+E1E51/45.0

    WAGO 750-405

    =N+E1E51

    -A75=N+E1E51/50.5

    WAGO 750-405

    =N+E1E51

    -A85=N+E1E51/55.5

    WAGO 750-405

    =N+E1E51

    -A95=N+E1E51/60.5

    WAGO 750-509

    =N+E1E51-A106

    =N+E1E51/66.0

    =N+M1T4-G1E

    =N+E1E51/3.3

    ABSOLUTENCODER

    WAGO 750-530

    =N+E1E51

    -A58=N+E1E51/36.0

    WAGO 750-466

    =N+E1E51

    -A67=N+E1E51/45.5

    WAGO 750-405

    =N+E1E51

    -A76=N+E1E51/51.0

    WAGO 750-405

    =N+E1E51

    -A86=N+E1E51/56.0

    WAGO 750-405

    =N+E1E51

    -A96=N+E1E51/61.0

    WAGO 750-509

    =N+E1E51-A107

    =N+E1E51/66.5

    WAGO 750-530

    =N+E1E51

    -A59=N+E1E51/37.0

    WAGO 750-405

    =N+E1E51

    -A77=N+E1E51/51.5

    WAGO 750-405

    =N+E1E51

    -A87=N+E1E51/56.5

    WAGO 750-405

    =N+E1E51

    -A97=N+E1E51/61.5

    WAGO 750-600

    =N+E1E51-A108

    =N+E1E51/80.1

    =N+M1P1-DESK

    WAGO 750-530

    =N+E1E51

    -A60=N+E1E51/38.0

    WAGO 750-405

    =N+E1E51

    -A98=N+E1E51/62.0

    =N+E1E51-PANEL

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    23/26

    01 COMMISSION 10.03.09

    D A T E

    :

    1 3

    .

    A p r

    i l

    2 0 0 6

    C A E

    :

    E P L A N

    5

    . 7 0

    . 3

    S P 1

    CON.NO.

    C -

    O

    5 7 0 E

    O B S E R V E

    P R O T E C T I O N

    M A R K

    A C C O R D I N G

    T O

    D I N

    3 4

    !

    14

    0

    REVI SI ON DATE

    ASG

    NAME

    1

    DATE

    COMM.

    CHECK

    STAND

    27.08.07

    A.Sengupta

    S.Suchanek

    16.04.09

    2

    ORIG. SUBST.

    3

    STEEL SLABCRANES 101/102/103CSA Brazil

    REPL.

    4

    THE POWER CONVERSIONCOMPANY

    5

    DESIGNATION:

    ETHERNET OVERVIEWCABIN

    6

    COMMISSION-No.:

    K147008

    CIRCUIT DIAGRAM

    7

    D4.147008

    DRAWING.-No.:

    8

    =

    +

    A

    9

    SHEET

    FROM

    15 v.100Bl.

    16

    15

    801

    =F0+E1H1-A15.1

    =F0+E1H1/17.1

    FOFESTOON

    2 4 V

    2 4 V

    2 3 0 V

    2 3 0 V

    2 4 V

    2 4 V

    =F1+F1E1-A15

    =F1+F1E1/9.2

    WAGO 750-341

    =F1+F1E1-A600

    =F1+F1E1/21.0

    WAGO 750-612

    =F1+F1E1-A611

    =F1+F1E1/24.2

    WAGO 750-554

    =F1

    +F1E1-A623=F1+F1E1/36.1

    WAGO 750-612

    =F1+F1E1-A651

    =F1+F1E1/37.1

    WAGO 750-405

    =F1+F1E1-A663

    =F1+F1E1/43.5

    WAGO 750-612

    =F1+F1E1-A701

    =F1+F1E1/44.2

    WAGO 750-612

    =F1+F1E1-A751

    =F1+F1E1/56.1

    FL SWITCH SF 4TX/FX ST

    WAGO 750-430

    =F1+F1E1-A601

    =F1+F1E1/22.0

    WAGO 750-430

    =F1+F1E1-A612

    =F1+F1E1/25.0

    WAGO 750-405

    =F1+F1E1-A652

    =F1+F1E1/38.0

    WAGO 750-430

    =F1+F1E1-A702

    =F1+F1E1/45.0

    WAGO 750-430

    =F1+F1E1-A752

    =F1+F1E1/57.0

    WAGO 750-430

    =F1+F1E1-A602

    =F1+F1E1/23.0

    WAGO 750-430

    =F1+F1E1-A613

    =F1+F1E1/26.0

    WAGO 750-405

    =F1+F1E1-A653

    =F1+F1E1/38.5

    WAGO 750-430

    =F1+F1E1-A703

    =F1+F1E1/46.0

    WAGO 750-430

    =F1+F1E1-A753

    =F1+F1E1/58.0

    WAGO 750-430

    =F1+F1E1-A614

    =F1+F1E1/27.0

    WAGO 750-405

    =F1+F1E1-A654

    =F1+F1E1/39.0

    WAGO 750-430

    =F1+F1E1-A704

    =F1+F1E1/47.0

    WAGO 750-430

    =F1+F1E1-A754

    =F1+F1E1/59.0

    WAGO 750-430

    =F1+F1E1-A615

    =F1+F1E1/28.0

    WAGO 750-405

    =F1+F1E1-A655

    =F1+F1E1/39.5

    WAGO 750-430

    =F1+F1E1-A705

    =F1+F1E1/48.0

    WAGO 750-430

    =F1+F1E1-A755

    =F1+F1E1/60.0

    =F1+F1P41-PANEL

    WAGO 750-430

    =F1+F1E1-A616

    =F1+F1E1/29.0

    WAGO 750-405

    =F1+F1E1-A656

    =F1+F1E1/40.0

    WAGO 750-430

    =F1+F1E1-A706

    =F1+F1E1/49.0

    WAGO 750-430

    =F1+F1E1-A756

    =F1+F1E1/61.0

    WAGO 750-430

    =F1+F1E1-A617

    =F1+F1E1/30.0

    WAGO 750-405

    =F1+F1E1-A657

    =F1+F1E1/40.5

    WAGO 750-430

    =F1+F1E1-A707

    =F1+F1E1/50.1

    WAGO 750-530

    =F1+F1E1-A757

    =F1+F1E1/62.0

    CABIN PANEL

    WAGO 750-430

    =F1+F1E1-A618

    =F1+F1E1/31.0

    WAGO 750-405

    =F1+F1E1-A658

    =F1+F1E1/41.0

    WAGO 750-430

    =F1+F1E1-A708

    =F1+F1E1/51.1

    WAGO 750-530

    =F1+F1E1-A758

    =F1+F1E1/63.0

    =F1+F1P4-PANEL

    WAGO 750-530

    =F1+F1E1-A619

    =F1+F1E1/32.0

    WAGO 750-405

    =F1+F1E1-A659

    =F1+F1E1/41.5

    WAGO 750-430

    =F1+F1E1-A709

    =F1+F1E1/52.1

    WAGO 750-530

    =F1+F1E1-A759

    =F1+F1E1/64.0

    WAGO 750-530

    =F1+F1E1-A620

    =F1+F1E1/33.0

    WAGO 750-405

    =F1+F1E1-A660

    =F1+F1E1/42.0

    WAGO 750-530

    =F1+F1E1-A710

    =F1+F1E1/53.0

    WAGO 750-530

    =F1+F1E1-A760

    =F1+F1E1/65.0

    WAGO 750-530

    =F1+F1E1-A621

    =F1+F1E1/34.0

    WAGO 750-405

    =F1+F1E1-A661

    =F1+F1E1/42.5

    WAGO 750-530

    =F1+F1E1-A711

    =F1+F1E1/54.0

    WAGO 750-600

    =F1+F1E1-A767

    =F1+F1E1/80.5

    WAGO 750-530

    =F1+F1E1-A622

    =F1+F1E1/35.0

    WAGO 750-405

    =F1+F1E1-A662

    =F1+F1E1/43.0

    WAGO 750-530

    =F1+F1E1-A712

    =F1+F1E1/55.0

    =F1+F1E1-PANEL

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    24/26

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    25/26

    01 COMMISSION 10.03.09

    D A T E

    :

    1 3

    .

    A p r

    i l

    2 0 0 6

    C A E

    :

    E P L A N

    5

    . 7 0

    . 3

    S P 1

    CON.NO.

    C -

    O

    5 7 0 E

    O B S E R V E

    P R O T E C T I O N

    M A R K

    A C C O R D I N G

    T O

    D I N

    3 4

    !

    8

    0

    REVI SI ON DATE

    ASG

    NAME

    1

    DATE

    COMM.

    CHECK

    STAND

    27.08.07

    A.Sengupta

    S.Suchanek

    16.04.09

    2

    ORIG. SUBST.

    3

    STEEL SLABCRANES 101/102/103CSA Brazil

    REPL.

    4

    THE POWER CONVERSIONCOMPANY

    5

    DESIGNATION:

    ETHERNET OVERVIEWPLC ROOM, LV DISTRIBUTION

    E-HOUSE

    6

    COMMISSION-No.:

    K147008

    CIRCUIT DIAGRAM

    7

    D4.147008

    DRAWING.-No.:

    8

    =

    +

    A

    9

    SHEET

    FROM

    9 v.100 Bl.

    10

    9

    801

    =F0+E1H1-A15.1

    =F0+E1H1/17.1

    =F0+E1H1-A15.1

    =F0+E1H1/17.1

    =F0+E1H1-A15.1

    =F0+E1H1/17.1

    2 4 V

    2 3 0 V

    2 4 V

    2 3 0 V

    2 4 V

    2 3 0 V

    WAGO 750-341

    =F0+E1H1-A80

    =F0+E1H1/45.0

    WAGO 750-612

    =F0+E1H1-A90

    =F0+E1H1/53.1

    WAGO 750-341

    =C+E1E02

    -A10=C+E1E02/30.0

    WAGO 750-461

    =C+E1E02

    -A21=C+E1E02/40.0

    WAGO 750-612

    =C+E1E02

    -A30=C+E1E02/43.1

    WAGO 750-341

    =C+E1E03

    -A30=C+E1E03/98.0

    WAGO 750-530

    =C+E1E03

    -A41=C+E1E03/108.0

    WAGO 750-612

    =C+E1E03

    -A50=C+E1E03/110.1

    WAGO 750-430

    =F0+E1H1-A82

    =F0+E1H1/46.0

    WAGO 750-405

    =F0+E1H1-A91

    =F0+E1H1/54.0

    WAGO 750-430

    =C+E1E02

    -A12=C+E1E02/31.0

    WAGO 750-461

    =C+E1E02

    -A22=C+E1E02/40.5

    WAGO 750-405

    =C+E1E02

    -A31=C+E1E02/44.0

    WAGO 750-430

    =C+E1E03

    -A32=C+E1E03/99.0

    WAGO 750-466

    =C+E1E03

    -A42=C+E1E03/109.1

    WAGO 750-405

    =C+E1E03

    -A51=C+E1E03/111.1

    WAGO 750-430

    =F0+E1H1-A83

    =F0+E1H1/47.0

    WAGO 750-405

    =F0+E1H1-A92

    =F0+E1H1/54.5

    WAGO 750-430

    =C+E1E02

    -A13=C+E1E02/32.0

    WAGO 750-492

    =C+E1E02

    -A23=C+E1E02/41.0

    WAGO 750-405

    =C+E1E02

    -A32=C+E1E02/44.5

    WAGO 750-430

    =C+E1E03

    -A33=C+E1E03/100.0

    WAGO 750-461

    =C+E1E03

    -A43=C+E1E03/109.6

    WAGO 750-405

    =C+E1E03

    -A52=C+E1E03/111.5

    WAGO 750-430

    =F0+E1H1-A84

    =F0+E1H1/48.0

    WAGO 750-405

    =F0+E1H1-A93

    =F0+E1H1/55.0

    WAGO 750-430

    =C+E1E02

    -A14=C+E1E02/33.0

    WAGO 750-492

    =C+E1E02

    -A24=C+E1E02/41.5

    WAGO 750-600

    =C+E1E02

    -A33=C+E1E02/49.5

    WAGO 750-430

    =C+E1E03

    -A34=C+E1E03/101.0

    WAGO 750-405

    =C+E1E03

    -A53=C+E1E03/112.1

    WAGO 750-430

    =F0+E1H1-A85

    =F0+E1H1/49.0

    WAGO 750-405

    =F0+E1H1-A94

    =F0+E1H1/55.5

    WAGO 750-430

    =C+E1E02

    -A15=C+E1E02/34.0

    WAGO 750-492

    =C+E1E02

    -A25=C+E1E02/42.0

    WAGO 750-430

    =C+E1E03

    -A35=C+E1E03/102.0

    WAGO 750-405

    =C+E1E03

    -A54=C+E1E03/112.5

    WAGO 750-530

    =F0+E1H1-A86

    =F0+E1H1/50.0

    WAGO 750-600

    =F0+E1H1-A95

    =F0+E1H1/61.5

    WAGO 750-430

    =C+E1E02

    -A16=C+E1E02/35.0

    WAGO 750-430

    =C+E1E03

    -A36=C+E1E03/103.0

    WAGO 750-405

    =C+E1E03

    -A56=C+E1E03/113.0

    WAGO 750-530

    =F0+E1H1-A87

    =F0+E1H1/51.0

    WAGO 750-430

    =C+E1E02

    -A17=C+E1E02/36.0

    WAGO 750-430

    =C+E1E03

    -A37=C+E1E03/104.0

    WAGO 750-405

    =C+E1E03

    -A57=C+E1E03/113.5

    WAGO 750-530

    =F0+E1H1-A88

    =F0+E1H1/52.0

    WAGO 750-430

    =C+E1E02

    -A18=C+E1E02/37.0

    WAGO 750-430

    =C+E1E03

    -A38=C+E1E03/105.0

    WAGO 750-405

    =C+E1E03

    -A58=C+E1E03/114.1

    =F0+E1H1-PANEL

    WAGO 750-530

    =C+E1E02

    -A19=C+E1E02/38.0

    WAGO 750-530

    =C+E1E03

    -A39=C+E1E03/106.0

    WAGO 750-405

    =C+E1E03

    -A59=C+E1E03/114.5

    WAGO 750-530

    =C+E1E02

    -A20=C+E1E02/39.0

    WAGO 750-530

    =C+E1E03

    -A40=C+E1E03/107.0

    WAGO 750-550

    =C+E1E03

    -A60=C+E1E03/115.1

    =F0+E1H2-PANEL

    =C+E1E02-PANEL

    WAGO 750-600

    =C+E1E03

    -A61=C+E1E03/121.5

    =C+E1E03-PANEL

    =C+E1E01-PANEL

    =C+E1E04-PANEL

  • 7/28/2019 CPO_S37_081103_MAL_Networks Manual.pdf

    26/26

    D A T E

    :

    1 3

    .

    A p r

    i l

    2 0 0 6

    C A E

    :

    E P L A N

    5

    . 7 0

    . 3

    S P 1

    C -

    O

    5 7 0 E

    O B S E R V E

    P R O T E C T I O N

    M A R K

    A C C O R D I N G

    T O

    D I N

    3 4

    !

    9

    0 1

    DATE

    COMM.

    27.08.07

    A.Sengupta

    2 3

    STEEL SLABCRANES 101/102/103CSA B il

    4 5

    DESIGNATION:

    ETHERNET OVERVIEW

    6

    CIRCUIT DIAGRAM

    7 8

    =

    +

    A

    9

    10 v.100Bl.

    11

    =F0+E1H1-A15.3

    =F0+E1H1/20.1

    2 4 V

    2 4 V

    2 3 0 V

    2 3 0 V

    2 3 0 V

    WAGO 750-341

    =H+E1E10-A200

    =H+E1E10/27.0

    WAGO 750-466

    =H+E1E10-A221

    =H+E1E10/39.1

    WAGO 750-612

    =H+E1E10

    -A230=H+E1E10/45.4

    WAGO 750-405

    =H+E1E10-A241

    =H+E1E10/51.0

    WAGO 750-405

    =H+E1E10-A253

    =H+E1E10/56.0

    WAGO 750-430

    =H+E1E10-A201

    =H+E1E10/28.0

    WAGO 750-466

    =H+E1E10-A222

    =H+E1E10/39.5

    WAGO 750-405

    =H+E1E10

    -A231=H+E1E10/46.0

    WAGO 750-405

    =H+E1E10-A242

    =H+E1E10/51.5

    WAGO 750-405

    =H+E1E10-A254

    =H+E1E10/56.5

    WAGO 750-430

    =H+E1E10-A202

    =H+E1E10/29.0

    WAGO 750-461

    =H+E1E10-A213

    =H+E1E10/40.0

    WAGO 750-405

    =H+E1E10

    -A232=H+E1E10/46.5

    WAGO 750-405

    =H+E1E10-A243

    =H+E1E10/52.0

    WAGO 750-405

    =H+E1E10-A255

    =H+E1E10/57.0

    =F0+E1H1-A15.2

    =F0+E1H1/19.1

    WAGO 750-430

    =H+E1E10-A203

    =H+E1E10/30.0

    WAGO 750-461

    =H+E1E10-A214

    =H+E1E10/40.5

    WAGO 750-405

    =H+E1E10

    -A233=H+E1E10/47.0

    WAGO 750-405

    =H+E1E10-A244

    =H+E1E10/52.5

    WAGO 750-405

    =H+E1E10-A256

    =H+E1E10/57.5

    WAGO 750-430

    =H+E1E10-A204

    =H+E1E10/31.0

    WAGO 750-461

    =H+E1E10-A215

    =H+E1E10/41.0

    WAGO 750-405

    =H+E1E10

    -A234=H+E1E10/47.5

    WAGO 750-405

    =H+E1E10-A245

    =H+E1E10/53.0

    WAGO 750-405

    =H+E1E10-A257

    =H+E1E10/58.0

    =H+M1T1-G11H1

    =H+E1E10/4.3

    ABSOLUTEENCODER

    WAGO 750-430

    =H+E1E10-A205

    =H+E1E10/32.0

    WAGO 750-461

    =H+E1E10-A216

    =H+E1E10/41.5

    WAGO 750-405

    =H+E1E10

    -A235=H+E1E10/48.0

    WAGO 750-405

    =H+E1E10-A246

    =H+E1E10/53.5

    WAGO 750-405

    =H+E1E10-A258

    =H+E1E10/58.5

    WAGO 750-430

    =H+E1E10-A206

    =H+E1E10/33.0

    WAGO 750-461

    =H+E1E10-A217

    =H+E1E10/42.0

    WAGO 750-405

    =H+E1E10

    -A236=H+E1E10/48.5

    WAGO 750-405

    =H+E1E10-A249

    =H+E1E10/54.0

    WAGO 750-600

    =H+E1E10-A261

    =H+E1E10/69.5

    WAGO 750-430

    =H+E1E10-A207

    =H+E1E10/34.0

    WAGO 750-461

    =H+E1E10-A218

    =H+E1E10/42.5

    WAGO 750-405

    =H+E1E10

    -A237=H+E1E10/49.0

    WAGO 750-405

    =H+E1E10-A250

    =H+E1E10/54.5

    =F0+E1H1-A15.2

    =F0+E1H1/19.1

    WAGO 750-530

    =H+E1E10-A210

    =H+E1E10/36.0

    WAGO 750-492

    =H+E1E10-A223

    =H+E1E10/43.1

    WAGO 750-405

    =H+E1E10

    -A238=H+E1E10/49.5

    WAGO 750-405

    =H+E1E10-A251

    =H+E1E10/55.0

    WAGO 750-530

    =H+E1E10-A212

    =H+E1E10/37.0

    WAGO 750-492

    =H+E1E10-A224

    =H+E1E10/44.1

    WAGO 750-405

    =H+E1E10

    -A239=H+E1E10/50.0

    WAGO 750-405

    =H+E1E10-A252

    =H+E1E10/55.5

    =H+M1T1-G12H2

    =H+E1E10/11.3

    ABSOLUTEENCODER

    WAGO 750-466

    =H+E1E10-A219

    =H+E1E10/38.1

    WAGO 750-405

    =H+E1E10

    -A240=H+E1E10/50.5

    =H+M1P51-DESK

    WAGO 750-466

    =H+E1E10-A220

    =H+E1E10/38.5

    =H+E1E10-PANEL


Recommended