    Run-time RAM Usage

    File integrity checking

    RecipePlus

    Run-time file to application file

    conversion

    Enhanced language switching

    New FactoryTalk View ME Features

  • 7/30/2019 CPR9 New Features

    2/12

    New feature in CPR 9 Part of the Terminal Configuration settings Allows for easy monitoring of terminal memory usage at runtime

    Can be enabled and disabled via Terminal settings

    Can also update memory usage values to HMI tags via Global Connections

    Can also be configured to start updating HMI tags via a remote Global Connection

    When to use this feature? It is strongly recommended that this feature be used during development and

    testing of FactoryTalk View ME applications to ensure that they do not exceed thelimitations of the hardware.

    Do this during development, do not wait until the application is being deployed atthe customers site you need to monitor these values right from the start!

    FactoryTalk View ME Runtime RAM Usage monitor

  • 7/30/2019 CPR9 New Features

    3/12

    Global Connections changed to tab format

    Memory tab added for this feature

    Design time options Global Connections

    FactoryTalk View ME Runtime RAM Usage

  • 7/30/2019 CPR9 New Features

    4/12

    Terminal Information Configuration Mode Screen

    Available on the CE Runtime only.

    Popup will appear every 10 seconds when enabled

    FactoryTalk View ME Runtime RAM Usage

  • 7/30/2019 CPR9 New Features

    5/12

    Total RAM Usage and Available RAM

    Monitor these two values to determine if the running application consumes the

    installed physical RAM on the terminal.

    You can add more memory to the terminal if these counters show high memoryusage.

    What do the numbers mean?

  • 7/30/2019 CPR9 New Features

    6/12

    Why enable this feature?

    Allows developers to monitor how much memory is used by the application when it

    is running.

    If the application is designed beyond the limitations of the PanelView Plus and

    PanelView Plus CE hardware, it should be modified to reduce memory usage, orpossibly deployed on a PC-based platform such as the VersaView Industrial PC.

    As the application is developed and tested, the application must be run on the

    PanelView Plus or PanelView Plus CE terminal with the ME Runtime RAM Usage

    feature enabled. The application developer should then navigate to all screens and

    exercise all functions of the application to monitor memory usage.

    Best Practices for Optimizing Performance & Memory

  • 7/30/2019 CPR9 New Features

    7/12

    File Integrity Check

    New in CPR9.

    Enabled by default, can be disabled in Terminal Settings. Will slow overall ME application startup time as it examines the files,

    slowdown is minimal.

    Warning messages help to identify file corruption issues that had

    previously caused terminals to be sent back for repair. EG: Corrupted Alarm log causes blue screen at startup.

    Validates the following: Alarm log

    Data log

    MER

    RSLinx Enterprise configuration files:

    RSLinxNG.xml, DefaultTemplate.xml. HardwareDatabase.xml

  • 7/30/2019 CPR9 New Features

    8/12

    CPR9 will containDelete/Rename

    capability

    RecipePlus

  • 7/30/2019 CPR9 New Features

    9/12

    CPR9 will contain Language Switching phase2 to include Alarms, Local and

    Information Messages. Alarm messages will be logged in the current language

    As a result the alarm log will contain messages in different languages if you areswitching languages at runtime.

    Only one language can be visible at development time.

    You must close Studio and re-open in a different language to edit/work in that language.

    Use the 4.00 CPR7+ Runtime Editing improvements, HMI Redundancyreplication, and String Spreadsheet editing patch to add the Export stringsfor all languages to an Excel spreadsheet

    This will allow you to edit one spreadsheet for all languages. Answer ID: 34125 Custom String Popup Keyboard ActiveX Control for RSView Machine

    Edition. Keypad support for Asian fonts Answer ID: 33400

    Make sure the fonts you want to use are linked on the terminal.

    Language Switching

  • 7/30/2019 CPR9 New Features

    10/12

    .

    Language Switching Enhancements CPR9

    String spreadsheet editing - text strings for all languages supportedby an application can be exported to a Microsoft Excel spreadsheet in one easy

    operation. You can also import text strings in one or multiple languages from an

    Excel spreadsheet to an application.

    Default language -each ME application now has a default language, not

    necessarily the initial language. Undefined strings are displayed in the default

    language instead of appearing as question marks.

    Enhanced language switching - application developers can viewuser-defined text strings in an application in up to 40 languages, and switch up to

    20 languages dynamically at run time. As well, information, alarm and localmessages now support language switching.

  • 7/30/2019 CPR9 New Features

    11/12

    MER to MED Application Conversion

    Run-time file to application file conversion- beginning with FactoryTalk Machine Edition 5.00, users can create a development file (also

    called a project file, or .med file) from a run-time file (.mer). This does not apply to .mer

    files made with earlier versions of RSView

  • 7/30/2019 CPR9 New Features

    12/12

    RSAsset Security

    A-P codes can now be entered in the Runtime Editor