PRESSURE VESSEL VISUAL INSPECTION REPORT Report #: EMD1703890-CC-02 Inspect Date: 04/07/2017 Page: 1 of 17 Insp. Co. Job #: EMD1703890 Criticality Designation: G G r r e e e e n n Insp. Comp: IRISNDT District: Bonnyville Heavy Oil Field: Location: North Brintnell Unit / Skid #: N/A LSD: 7-27-82-21W4 Jurisdiction #: A0439721 Equip Tag #: TR-2701C Serial #: 6975-03 CRN #: N8032.2 Nat’l Bd #: Year Built: 1997 Manufacturer: Natco Canada LTD. Equipment Description: Other: Treater Status: In Service - Standby Equip. Type: Vessel: Treater Service: Sour MAWP Shell: Side: 75 Psi @ 300 °F Volume: 223 Code Stamp: Y N MAWP Tube: Side: @ Height/Length: 840 in. Insulated: Y N MDMT: -20 °C RT: RT-1 Size/Diameter.: 144 in. O.D. PWHT: Y N Support Type: Saddle Vessel on Original CNRL Inventory List: Y N Manway: Y N C.A.: 0.125 in. Coated: Yes Clad: No J.E.: Remote Access: - Component Material Nominal Thk Diameter OD/ID Tube Side Shell Side 1 Main - Shell SA-516-70N 0.500 in. 144.000 in. OD 2 East - Head SA-516-70 0.560 in. 144.000 in. OD 3 West - Head SA-516-70 0.560 in. 144.000 in. OD 4 - 5 - Static Data: Confirmed Changed (See Comments) Comments: No MDR was provided. All information should be confirmed prior to overwriting database PSV Static Data PSV 1 Tag #: 13382 Serial #: 531713 CRN: 0G8841.5C Model #: 26PA10-120 Capacity: 506 USGPM Set Pressure: 75 psi Manufacturer: Mercer Service Company: Apex Inlet Size & Type: 3.00 in. - Flanged Last Service Date: June 1, 2017 Outlet Size & Type: 4.00 in. - Flanged Block Valve: - - Carseal Intact: Code Stamp: Yes Shell Side / Tube Side: Out for Service During Insp.: Y Location of PSV: PSV 2 Tag #: Serial #: CRN: Model #: Capacity: Set Pressure: Manufacturer: Service Company: Inlet Size & Type: - Last Service Date: Outlet Size & Type: - Block Valve: - - Carseal Intact: Code Stamp: Shell Side / Tube Side: Out for Service During Insp.: Location of PSV: PSV Comments The PSV was removed for servicing during the visual inspection
Transcript
Page 1: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 1 of 17

Insp. Co. Job #: EMD1703890

Criticality Designation:

GGGrrreeeeeennn

Insp. Comp: IRISNDT District: Bonnyville Heavy Oil Field:

Location: North Brintnell Unit / Skid #: N/A LSD: 7-27-82-21W4

Jurisdiction #: A0439721 Equip Tag #: TR-2701C Serial #: 6975-03

CRN #: N8032.2 Nat’l Bd #: Year Built: 1997

Manufacturer: Natco Canada LTD. Equipment Description: Other: Treater

Status: In Service - Standby Equip. Type: Vessel: Treater Service: Sour

MAWP Shell: Side:

75 Psi @ 300 °F Volume: 223 m³ Code Stamp: Y N

MAWP Tube: Side:

@ Height/Length: 840 in. Insulated: Y N

MDMT: -20 °C RT: RT-1 Size/Diameter.: 144 in. O.D. PWHT: Y N

Support Type:

Saddle Vessel on Original CNRL Inventory List: Y N Manway: Y N

C.A.: 0.125 in. Coated: Yes Clad: No J.E.: Remote Access: -

Component Material Nominal Thk Diameter OD/ID Tube Side Shell Side

1 Main - Shell SA-516-70N 0.500 in. 144.000 in. OD

2 East - Head SA-516-70 0.560 in. 144.000 in. OD

3 West - Head SA-516-70 0.560 in. 144.000 in. OD

4 -

5 -

Static Data: Confirmed Changed (See Comments)

Comments: No MDR was provided. All information should be confirmed prior to overwriting database

PSV Static Data

PSV –1 Tag #: 13382 Serial #: 531713 CRN: 0G8841.5C

Model #: 26PA10-120 Capacity: 506 USGPM Set Pressure: 75 psi

Manufacturer: Mercer Service Company: Apex

Inlet Size & Type: 3.00 in. - Flanged Last Service Date: June 1, 2017

Outlet Size & Type: 4.00 in. - Flanged Block Valve: - -

Carseal Intact: Code Stamp: Yes

Shell Side / Tube Side: Out for Service During Insp.: Y Location of PSV:

PSV –2 Tag #: Serial #: CRN:

Model #: Capacity: Set Pressure:

Manufacturer: Service Company:

Inlet Size & Type: - Last Service Date:

Outlet Size & Type: - Block Valve: - -

Carseal Intact: Code Stamp:

Shell Side / Tube Side: Out for Service During Insp.: Location of PSV:

PSV Comments

The PSV was removed for servicing during the visual inspection

Page 2: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 2 of 17

Insp. Co. Job #: EMD1703890

Insp. Company: IRISNDT LSD: 7-27-82-21W4 Jurisdiction #: A0439721

External Inspection Results – VE External Inspection Performed

Item N/A Condition Comment (Check Status Bar or Press F1 for Help)

NCR Action Item

Integrity Action Item

Maintenance

Nameplate Accept Clear & legible

Foundation and Supports Accept No deformation or damage

Anchor Bolts Accept The bolting was in good condition

Grounding Accept The vessel is properly grounded

Insulation Condition Accept Carbon build up found on the cladding

PSV PSV was removed for servicing

Shell Heads & Nozzles Accept Not visible due to insulation

Metal Surfaces (Paint) Accept Not visible due to insulation

Aux Equipment

Cathodic Protection Accept Anode were being replaced during inspection

Alignment Accept Appears straight and level

Flange Connections Accept Flange connections were securely fastened

Pressure Gauge Accept Clean and legible

Temperature Gauge Accept Clean and legible

Sight Glass Accept Clean and legible

Ladder / Platform Accept No issues found found

Leaks No Signs of leaking found at a hose connection

Piping from Vessel Accept Securely fastened

Previous UT Survey No N/A UT Company:

External Visual Observations

A full visual assessment was performed on A0439721, treater, as part of a thorough assessment of the equipment for continued service. The site is considered to be in sour service. The vessel was in not in service at the time of inspection. No qualitative vibration assessment could be made. There was no evidence of leaking found at the threaded bolt connection where the hose connects on the top of the treater, located where the permanent scaffolding is located. The horizontal vessel is 90% contained within the existing skid structure, with only the head and burner/stack residing outside the building. The vessel appeared to be straight and level and no deflection, deformation or corrosion was noted in any supporting structure. The saddle support is welded to the shell and the base of the saddles are welded to the floor of the skid. No cracking was noted in any weld. The vessel is 100% insulated. All insulation/cladding on the vessel was free of rips, tears, bulges and dents. No visible evidence of environmental ingress through the cladding to insulation or pressure boundary beneath was found All piping was well supported with no significant visible evidence of external corrosion or damage.

Recommendations:

Carbon build up on the east side of the treater where the burners were.

Page 3: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 3 of 17

Insp. Co. Job #: EMD1703890

Insp. Company: IRISNDT LSD: 7-27-82-21W4 Jurisdiction #: A0439721

Internal Inspection Results – VI Internal Inspection Performed

Item N/A Condition Comment (Check Status Bar or Press F1 for Help)

NCR Action Item

Integrity Action Item

Maintenance

Shell Accept No deformations found.

Heads Accept No deformations found.

Manway Accept Coating damage found on the burner side.

Gasket Surfaces Accept No damage found.

Welds Accept Properly coated and in good condition

Refractory Not installed

Heating Coils Accept Removed during inspection.

Demister Pad Not Installed

Vane Pack Not Installed

Baffles Not Installed

Trays Removed during inspection.

Filter Not Installed

Internal Coating Accept Coating damage found on both ends.

Tubesheet Not Installed

Tube Bundle Not Installed

Internal Visual Observations

-Most of the internal was clean and able to be inspected. -The anodes appear to be working, they are about 60-70% deteriorated. -There were no issues with any of the welds inside the treater. -All of the sample points were clear of debris and any damage. -All bolting and flange connections inside the treater were tight and securely fastened. -All piping was removed from the treater during the inspection, piping appeared to be in good condition. -The coating on the burner side is blistering and disbonding from the shell of the treater. The primary locaction of the blistering was found at the emulsification area around the entire burner side. -Coating lost was found on the south side of the treater. UT was performed around that area and no materal loss was found during the inspection. Coating lost also noticed around the manway enterances. Chipped coating also noticed at ramdon location through the burner side. -Coating blistering was found around the emulsification zone on the serperation side throughout. -Coating disbondment found on the north wall near the emulsification zone. on the separation side. -Small coating chips less than an 1" in size found on the separation side.

Recommendations:

Replace anodes to help protect the vessel. Re-coating is recommended on the interior of the treater on the burner and separation side.

Page 4: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 4 of 17

Insp. Co. Job #: EMD1703890

Insp. Company: IRISNDT LSD: 7-27-82-21W4 Jurisdiction #: A0439721

Firetube Static Data N/A (Not Applicable)

Diameter: Not Applicable in. Nom Thickness: Not Applicable Bend: Not Applicable

Length: Not Applicable in. Firetube Description: Not Applicable

Firetube NDE

Performed:

UT Report#: Not Applicable ET Report#: Not Applicable

MT Report#: Not Applicable RT Report#: Not Applicable

PT Report#: Not Applicable Other Report#: Not Applicable

Firetube Inspection Results

Item N/A Condition Comment (Check Status Bar or Press F1 for Help)

NCR Action Item

Integrity Action Item

Maintenance

Burner No Firetube Inspection Carried Out

Stack No Firetube Inspection Carried Out

Flange (Throat) No Firetube Inspection Carried Out

Tube Sheet No Firetube Inspection Carried Out

Hot Side No Firetube Inspection Carried Out

Miter No Firetube Inspection Carried Out

Return Bend No Firetube Inspection Carried Out

Supports No Firetube Inspection Carried Out

Butt Welds No Firetube Inspection Carried Out

Fillet Welds No Firetube Inspection Carried Out

Firetube Visual Observations

No Firetube Inspection Carried Out

Recommendations:

No Firetube Inspection Carried Out

Page 5: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 5 of 17

Insp. Co. Job #: EMD1703890

Insp. Company: IRISNDT LSD: 7-27-82-21W4 Jurisdiction #: A0439721

Vessel NDE and Final Summary:

NDE Performed:

UT Report#: ET Report#:

MT Report#: RT Report#:

PT Report#: Other Report#:

Maxi-Trak Observations Summary (Summarize inspection results Max 255 Characters):

Coating loss found inside the treater, no material loss or corrosion found on the shell of the vessel.

Anodes were found to be 60-70% deteriorated.

Maxi-Trak Recommendations Summary (Summarize Recommendations Max 255 Characters):

Replace anodes to help protect the vessel.

Re-coating is recommended on the interior of the treater on the burner and separation side.

Actions Corrected at Time of Inspection: (If actions were corrected at the time of Inspection – note the corrected actions here.)

None

Additional Visual Observations

None

Any other safety concerns or observations from associated equipment: (for example associated piping, buildings, pumps etc…)

None

Page 6: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 6 of 17

Insp. Co. Job #: EMD1703890

Insp. Company: IRISNDT LSD: 7-27-82-21W4 Jurisdiction #: A0439721

Thickness and Remaining Life Evaluation “ Must be Completed”

MUST BE COMPLETED AND RESOLVED WITH CNRL IMMEDIATELY UPON DISCOVERY OF LOW WALL THICKNESS AREAS Step 1: Was any thickness measurement location found to be less than (Nominal WT – Corrosion Allowance)?: If YES, proceed to Step 2; if NO, proceed to “Crack Evaluation” and “CNRL Criticality Designation”.

Step 2: Which component(s) were found below (Nominal WT – Corrosion Allowance)? Components found below Nom - CA:

Components

N/A - N/A

N/A - N/A

N/A - N/A

N/A - N/A

N/A - N/A

Perform Steps 3 – 8 for each component with actual thickness less than (Nominal WT – Corrosion Allowance). Step 3: Describe Location and Extent of Corrosion: Components Location and Extent of Corrosion

N/A - N/A Not Applicable for this inspection

N/A - N/A Not Applicable for this inspection

N/A - N/A Not Applicable for this inspection

N/A - N/A Not Applicable for this inspection

N/A - N/A Not Applicable for this inspection

Notes: Not Applicable for this inspection

Step 4:

For shells and nozzles, calculate minimum required thickness (T-min) as per ASME Section VIII UG-27.

For heads, calculate minimum required thickness (T-min) as per ASME Section VIII UG-32. Components T-Min

N/A - N/A N/A

N/A - N/A N/A

N/A - N/A N/A

N/A - N/A N/A

N/A - N/A N/A

Page 7: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 7 of 17

Insp. Co. Job #: EMD1703890

Insp. Company: IRISNDT LSD: 7-27-82-21W4 Jurisdiction #: A0439721

Thickness and Remaining Life Evaluation (Continued)

Step 5: Is any measured thickness less than calculated minimum required thickness (T-min)? N/A

If YES, complete Step 6 If NO, proceed to Step 7..

Step 6: Is nature and extent of pitting acceptable as per API 510? N/A Step 7: Calculate Remaining Life as per API 510. How? (Find last reading; use nominal thickness if nothing available). Short Term Corrosion Rates and Long Term Corrosion Rates.

Remaining Components Life (Yrs)

N/A - N/A N/A

N/A - N/A N/A

N/A - N/A N/A

N/A - N/A N/A

N/A - N/A N/A

Step 8: Contact CNRL Integrity Coordinator to discuss above results.

Name of CNRL contact: N/A

Date and time of conversation: N/A

Summary/results of conversation:

N/A

Crack Evaluation by Magnetic Particle or Alternative Inspection “ Must be Completed”

MUST BE COMPLETED AND RESOLVED WITH CNRL IMMEDIATELY UPON DISCOVERY OF CRACK-LIKE INDICATIONS

Were any indications found to suggest the vessel contained cracks? N/A

If NO, proceed to “CNRL Criticality Designation”. If YES, Contact CNRL Integrity Coordinator to discuss results.

Name of CNRL contact: Not Applicable for this Inspection

Date and time of conversation: Not Applicable for this Inspection Summary/results of conversation:

Not Applicable for this Inspection

Page 8: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 8 of 17

Insp. Co. Job #: EMD1703890

Insp. Company: IRISNDT LSD: 7-27-82-21W4 Jurisdiction #: A0439721

CNRL Criticality Evaluation – “MUST BE COMPLETED”

The CNRL In-Service Pressure Vessel Inspector MUST answer all the following questions

1. Is the vessel fit-for-service? : Yes

2. Was the measured thickness less than the calculated minimum required thickness (T-min) for any component?: No

3. Were MT indications found?: N/A

4. Was the remaining life less than 6 years for sour service vessels or less than 10 years for sweet service vessels?: No

5. Were NCR’s or Action Items generated as a result of the inspection? : No

6. Were UT readings below (Nominal WT – Corrosion Allowance) found? : No

Information on CNRL Owner User Program - Criticality Designation and Required Review RED – Vessel Inspection Results are deemed RED if one of the following occurred:

The measured thickness was less than the calculated minimum required thickness (T-min) for any component.

MT indications were found.

The remaining life was calculated to be less than 6 years for sour-service vessels or less than 10 years for sweet-service vessels.

RED inspection reports must be signed off by the CNRL Chief Inspector.

YELLOW – Vessel Inspection Results are deemed YELLOW if one or more of the following occurred:

The vessel was declared NOT fit-for-service by the 3rd Party In-Service PV Inspector.

NCR’s or Action Items were generated as a result of the inspection.

UT readings below (Nominal WT – Corrosion Allowance) were found. YELLOW inspection reports must be signed off by the CNRL Pressure Equipment Integrity Coordinator. GREEN – Vessel Inspection Results are deemed GREEN if all of the following are true:

The vessel was declared fit-for-service by the 3rd Party In-Service PV Inspector.

UT readings below (Nominal WT – Corrosion Allowance) were NOT found.

MT indications were NOT found.

NCR’s or Action Items were NOT generated as a result of the VE inspection. GREEN inspection reports must be signed off by the 3rd Party In-Service Pressure Vessel Inspector.

Criticality Designation GGGrrreeeeeennn

Vehicle #: 597 Kms: 640 Inspector (Name): Camille Chesterman PESL:

Time In: Time Out: Hrs Inspector (Signature):

API: 51167

Time In: Time Out: Hrs CNRL Coordinator (Name):

Personnel: Camille Chesterman CNRL Coordinator (Signature):

Billing Info: P.O. : CNRL Chief Inspector (Signature): (I am in full agreement with report contents)

(I am in full agreement with report contents)

06 /03 /2 01 7 1 2 :01 :02 p m

06 /3 0/2 01 0 08 :4 4 :03 a m

06 /3 0/2 01 0 08 :4 5 :2 9 a m

Page 9: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 9 of 17

Insp. Co. Job #: EMD1703890

TR-2701C Photo's

Figure 01-Overview

Figure 02- Nameplate

Page 10: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 10 of 17

Insp. Co. Job #: EMD1703890

Figure 03- PSV Location (Removed)

Figure 04- Carbon found on the insulation cladding

Page 11: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 11 of 17

Insp. Co. Job #: EMD1703890

Figure 05- Guages are clear and legible

Figure 06- Piping is in good condition.

Page 12: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 12 of 17

Insp. Co. Job #: EMD1703890

Figure 07- Anodes are about 60-70% deteriorated

Figure 08-Burner side Overview

Page 13: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 13 of 17

Insp. Co. Job #: EMD1703890

Figure 09- Coating disbondment and chipping found on both manways.

Figure 10- Blistering found at the emulsification level on the east head.

Page 14: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 14 of 17

Insp. Co. Job #: EMD1703890

Figure 11- Blistering found on the south shell side.

Figure 12- Coating loss found on the south shell side near the separation side.

Page 15: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 15 of 17

Insp. Co. Job #: EMD1703890

Figure 13- Separation side overview.

Figure 14- Blistering found aroud the emulsification zone through out.

Page 16: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 16 of 17

Insp. Co. Job #: EMD1703890

Figure 15- Small chips in the coating found at varous locations.

Figure 16- coating disbondment found on the north shell side.

Page 17: Criticality Designation: G r e e n GGrreeeenn

PRESSURE VESSEL VISUAL INSPECTION REPORT

Report #: EMD1703890-CC-02

Inspect Date: 04/07/2017

Page: 17 of 17

Insp. Co. Job #: EMD1703890

Figure 17- Coating loss & disbondment found on the north shell side


Recommended