1 2
3 4
5 6
7
1
2
3 4
5 6
7
0
5
10
15
20
25
30
0 10 20 30 40 50 60 70 80 90 100
CrossLabAgilent
Purchasing supplies for your Perkin Elmer GC systems is easy with Agilent CrossLab
Liner O-rings
Description Unit
Similar toManufacturerPart No.
Agilent CrossLabPart No.
Non-stick fluoroelastomer O-ring 10/pk N9302783 8010-0401
Non-stick fluoroelastomer O-ring, PSS Injector 10/pk N6101747 8003-0202
Silicone O-ring 10/pk N6101374 8003-0203
Graphite O-ring, PSS Injector 10/pk N6101751 8003-0204
Graphite O-ring 10/pk N6101378 8003-0205
Column Nuts
Description Unit
Similar toManufacturerPart No.
Agilent CrossLabPart No.
Column nut, 1/16 in. 2/pk 09903392 8003-0311
Autosampler Syringes for PerkinElmer GC Systems, 1/pk
ModelVolume
(µL) DescriptionNeedle Gauge/Length (mm)/Tip
Similar to Mfr.Syringe Part No.
Agilent CrossLabSyringe Part No.
Similar to Mfr.Replacement Needleand Plunger Repair Kit Part No.
Agilent CrossLabReplacement Needleand Plunger Repair Kit Part No.
AutoSystem, Autosystem XL, Clarus 0.5 Removable needle 23/70/cone tip N6101252 8003-0005 N6101469 8003-0006
Removable needle 26/70/bevelled cone tip 8003-0007 8003-0008
5 Fixed needle 23/70/cone tip N6101251 8003-0001
Fixed needle, gas tight 23/70/cone tip N6101390 8003-0002
Fixed needle 26/70/cone tip N6101380 8003-0003
50 Fixed needle 23/70/cone tip N6101760 8003-0004
Non-Stick Bleed and Temperature Optimized (BTO) Septa
Description
Similar toManufacturerPart No.
Agilent CrossLabPart No. 50/pk
Agilent CrossLabPart No. 100/pk
11 mm, CenterGuide N9302972 8010-0223 8010-0224
Non-Stick Advanced Green Septa
11 mm, CenterGuide N6621028N9306219
8010-0207 8010-0208
Non-Stick Long-Life Septa
11 mm, CenterGuide 8010-0239 8010-0240
General Purpose Septa
11 mm 54019985 8010-0255 8010-0256
Advantage Liner type: Splitless single taper liners with woolHigh level ofdeactivation/inertness
ü Better peak shapes for active compounds at trace levels
ü Lower detection limits
üMore accurate quantification
Minimal compound lossand degradation
üMore accurate quantification
ü Lower detection limits
üMore reliable results, and less preventive maintenance
Effective deactivationcoverage for wool-packed liners
ü Ability to use wool – even with highly active compounds
ü Reduced compound discrimination and column contamination
ü Better column protection, and less preventive maintenance
Lot tested withdemanding test probes
ü Reproducible deactivation coverage
ü Reliably inert flow path for active compounds at trace levels
üMore accurate quantification
Touchless packaging ü Easy installation without touching the liner
ü Less troubleshooting due to contamination
ü Ensures proper installation for longer instrument uptime
• A large, diverse portfolio of essential GC supplies• Packaged for easy access and improved productivity• Backed by our risk-free 90-day guarantee
To learn more about the full Agilent CrossLab GC supplies portfolio, visit www.agilent.com/chem/CrossLab
Agilent Ultra Inert deactivation with wool contributes to higher responseand better peak shape for very active forensic basic drug compounds thana liner with active sites.
Endrin: 100 ppbLiner type: Splitless single taper liners with woolDetector: ECD
Recalibrationrequired
Injection #
Liner with active sites (n=4) Agilent Ultra Inert deactivation (n=4)
% E
ndrin
Bre
akdo
wn
Agilent Ultra Inert deactivation with wool
Higher response
Better peak shape
Peak identification:
Liner with active sites with wool
OxycodoneTemazepamFlunitrazepam
NitrazepamClonazepamAlprazolam
Certified performance: Every liner is packaged with aCertificate of Performance that you can peel and stickinto your lab notebook for quick compliance reference.
Easy traceability: The deactivation lot number is printeddirectly on the certificate; the liner lot number and partnumber are permanently etched on the liner glass.
Visit www.agilent.com/chem/CrossLabUILiners
• Keep gas lines clean and leak free• Protect your instrument and GCcolumn with sensitive indicators
• Stabilize quickly to enhanceproductivity and reduce helium gas consumption
Minimize downtime on your non-Agilent HPLC instruments
Agilent CrossLab Services:
• Multi-vendor repair and maintenance• Compliance• Laboratory relocation services
Liners for AutoSystem, AutoSystem XL, Clarus Systems
DescriptionID
(mm)OD
(mm)Length (mm)
Volume (µL) Unit
Similar toManufacturerPart No.
AgilentOriginalDeactivation
Similar toManufacturerPart No.
AgilentUltra InertDeactivation
Split/Splitless Liners
PSS straight 2.0 4.0 86.2 5/pk 8003-0103 N6502002 8003-0153
PSS straight with bottom restriction 2.0 4.0 86.2 260 5/pk N6121004 8003-0158
PSS on-column 2.0 4.0 86.2 250 5/pk N6101539 8003-0110 N6101539 8003-0165
PSS straight 1.0 4.0 86.2 65 5/pk N6121006 8003-0157
Split/Large Volume Splitless Liners
Straight with bottom restriction 4.0 6.2 92.1 1150 5/pk N6121001 8003-0105 N6121001 8003-0159
Splitless Liners
Straight 2.0 6.2 92.1 300 5/pk N6101372 8003-0107 N6101372 8003-0162
Split Liners
Straight-through 4.0 6.2 92.1 1150 5/pk 8003-0101 8003-0151
Straight, wool 4.0 6.2 92.1 1100 5/pk N6121020 8003-0106 N6121020 8003-0160
Straight with bottom restriction 4.0 6.2 92.1 1100 5/pk N6101052 8003-0111 N6101052 8003-0166
Direct Liners
Gooseneck, drilled hole on top, wool 4.0 6.2 92.1 5/pk N6121022 8003-0155
Other Liners
Packed column, straight 3.0 6.2 112 800 5/pk N6121000 8003-0108 N6121000 8003-0163
Programmable on-column, hour glass 2.2 4.0 16 5/pk N6101703 8003-0109*
PTV, 0.25 mm ID restriction, recessed gooseneck
1.0 2.0 88 70 5/pk 8003-0104 8003-0154
*P/N 8003-0109 is not deactivated
Agilent CrossLab works with
Capillary Column Ferrules
ModelFitting Size
(in.)Ferrule ID
(mm)Column ID
(mm) Hole Unit
Similar toManufacturerPart No.
Agilent CrossLabPart No.
85% Vespel/15% Graphite Capillary Column Ferrules
AutoSystem, Autosystem XL, Clarus 1/16 0.4 0.25 1 10/pk 09920104 8010-0310
1/16 0.4 0.25 2 10/pk 04972392 8010-0312
1/16 0.5 0.32 1 10/pk 09920105 8010-0311
1/16 0.5 0.32 2 10/pk N9306000 8003-0216
1/16 0.8 0.53 1 10/pk 09920107 8010-0313
Vespel Capillary Column Ferrules
AutoSystem, Autosystem XL, Clarus 1/16 0.3 0.18 mm ID or smaller 1 10/pk 8010-0306
1/16 0.4 0.25 1 10/pk 8010-0307
1/16 0.5 0.32 1 10/pk 8010-0308
1/16 0.8 0.53 1 10/pk 8010-0309
Graphite Capillary Column Ferrules
AutoSystem, Autosystem XL, Clarus 1/16 0.4 0.25 1 10/pk 8010-0301
1/16 0.5 0.32 1 10/pk 09903700 8010-0302
1/16 0.5 0.32 1 10/pk N9306001 8010-0303
1/16 0.8 0.53 1 10/pk 09920141 8010-0304
Packed Column Ferrules
ModelFitting Size
(in.)Ferrule ID
(in.)Column OD
(in.) Hole Unit
Similar toManufacturerPart No.
Agilent CrossLabPart No.
85% Vespel/15% Graphite Packed Column Ferrules
AutoSystem, Autosystem XL, Clarus 1/4 1/4 1/4 1 10/pk 09903739 8010-0314
1/8 1/8 1/8 1 10/pk N9302081 8003-0219
1/16 1/16 1/16 1 10/pk 09920127 8010-0315
Vespel Packed Column Ferrules
AutoSystem, Autosystem XL, Clarus 1/4 1/4 1/4 1 10/pk N9301361 8003-0223
1/8 1/8 1/8 1 10/pk N9301360 8003-0222
1/16 1/16 1/16 1 10/pk 8003-0221
Graphite Packed Column Ferrules
AutoSystem, Autosystem XL, Clarus 1/4 1/4 1/4 1 10/pk 09920140 8010-0305
1/8 1/8 1/8 1 10/pk 09903915 8003-0212
1/16 1/16 1/16 1 10/pk 02450972 8003-0211
Bring the benefits of Ultra Inert liners to your whole labInlet liners are a critical link in your sample flow path; however, they can also be a source of activity and analyte loss. Agilent CrossLab Ultra Inert inlet liners solve these problems with a highly inert chemistrythat maximizes sample transfer while minimizing analyte loss.
After 101 injections, the Agilent Ultra Inert deactivation shows significantlyless decomposition than competitive liner deactivations.
Download your complete Agilent CrossLab Quick Reference Guidefor PerkinElmer GC Systems by scanning this QR code.
Liner Body Lot: A0023Deactivation Lot: B39020
Certificate of Performance
8002-0157 Ultra Inert LinerPTV, Strt W/bot Restrict, 2 mm 5pk
This information is subject to change without notice.
© Agilent Technologies, Inc. 2012Printed in USA July 11, 2012
5991-0430EN
BRUKER/VARIAN CTC PERKINELMER SHIMADZU THERMO AND MORE
Agilent CrossLab vials, closures, and septa stop unknown peaks from impacting your results• Cleanliness and consistency for precision lab work• Engineered with the same quality as Agilent instruments • Flawless performance with former Varian autosamplers• Wide selection: choose the right vial for your needs atwww.agilent.com/chem/SelectVials
The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the CrossLab products are viablealternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products mayhave slightly different designs as compared to the OEM counterparts. All Agilent CrossLab supplies are backed by Agilent's 90-day money-back warranty.
Supplies for Perkin Elmer GC Systems
From injection through instrument… count on Agilent for everything that touches your sample
Put decades of Agilent innovation behind every separation
Agilent J&W GC columns:
• Largest portfolio of innovativeGC columns, over 3700
• Best inertness, lowest bleed,tightest reproducibility
• Quality ensured by moststringent testing in the industry
Agilent Bond Elut SPE, Bond Elut QuEChERS and Captiva Filtration Sample Prep family of products offer the widestrange of solutions for every level of sample cleanliness to help you increase throughput and increase the quality of your data
Deliver the cleanest gas for your most reliable analysis
Agilent Gas Clean filters:
Proof that Agilent CrossLab Ultra Inert liners deliversuperior deactivation performance
Your first choice for reproducible sample prep
Agilent Sample Prep products: