+ All Categories
Home > Documents > Cryo-derm

Cryo-derm

Date post: 05-Aug-2015
Category:
Upload: beaumedic
View: 30 times
Download: 0 times
Share this document with a friend
Popular Tags:
23
CRYO-DERM IONTOPHORESIS + MSG REJUVENATION + Electroporation
Transcript
Page 1: Cryo-derm

CRYO-DERM IONTOPHORESIS + MSG

REJUVENATION + Electroporation

Page 2: Cryo-derm

CRYO-DERM

2

INDEX

1. Name and Components

2. Direction to Use

3. Features of Cryo_Derm

4. Principle and Effects of

Cryoelectrophoresis

5. Cryo_Derm Program

6. Cryo_Derm Treatment

7. Specification

8. Warranty Information

Page 3: Cryo-derm

CRYO-DERM

3

1. Name and Components

② CRYO & THERMO ELECTROPORATION

② ELECTRO MESO MEDICINE & SOLUTION INJECTION

<Accessories>

PART NAME IMAGE PART NAME IMAGE

Cryo & Thermo

Electrode

Hand piece

Earth Rod

Cryo & Thermo

Electrode for

Body

Injection

Electrode

Hand piece

Earth Rod

Foot Switch for

Injection

Page 4: Cryo-derm

CRYO-DERM

4

1. Name and Components

CH.1 Cryo/thermo Control Common Control CH.2 Injection Electrode Control

1CH: Cryo/Thermo Electrode Control

① <MODE> button: Choose Cryo or Thermo Electrode Function

Choose one among 5 modes like Ion soft, Ion hard, Ion lift, Ion MSG, Rejuvenation

② <OFF/MAX> button: Output Intensity of Cryo/Thermo

Amount of Output for Cryo/Thermo and Ion, Ion Lift, Rejuvenation stimulation

③ <PLUS/MINUS> Polarity button: Choose one between (+) and (-)

Choose one when use of Ion soft, Ion hard, Ion lift functions

④ ⑤ <TEMP UP/DOWN>: Settle up temp. using UP/DOWN

COLD -10 ~ +10 HOT +35 ~ +45

2CH: Injection Electrode Control

⑤ <MODE>button: Choose Injection Electrode function

Choose one among 5 modes like Ion soft, Ion hard, Ion lift, Ion MSG, Rejuvenation

⑥ <OFF/MAX> button: Output Intensity of Injection Electrode

Amount of Output for Generating Cryo/Thermo and Ion, Ion Lift, Rejuvenation stimulation.:

⑦ <PLUS/MINUS> Polarity button: Choose one between (+) and (-)

Choose one when use of Ion soft, Ion hard, Ion lift functions

⑧ <FLOW SPEED> control button for volumes of flow

control the volumes of injection flow of ampoule

Page 5: Cryo-derm

CRYO-DERM

5

1. Name and Components

Common Control

⑨ <TIME> button: Control time to use. / Setting time: 20min.

⑩ <START/STOP> button

Start/stop the output for Ion, Ion Lift, Rejuvenation stimulation

Objects of Use

- Ampoule Application

- Sedation of sensitive skin, Pore minimization, Increase of blood circulation

- Ion penetration, Skin lift, Skin rejuvenation

This device, Cryo_Derm, is possible to apply to two people at the same time.

HOWEVER, it is impossible to apply ION soft & hard at the same time.

That is

When selection of ION HARD, ION SOFT on 1CH cryo/thermo electrode Mode,

It is not able to use two functions of 2CH.

At this time, ION LIFT, ION MSG, REJUVENATION is only able to be used on 2CH injection mode.

Stand by Screen Processing Screen

Page 6: Cryo-derm

CRYO-DERM

6

2. Direction to Use

Direction to use for CH. 1 : Cryo/Thermo Elcetrode

CH.1 Cryo/thermo Control Common Control CH.2 Injection Electrode Control

1. Usage of CH.1 Cryo/Thermo Elcetrode

Start treatment after checking it whether client grip Ground Rod

① <①Mode>- Choose one among 5 functions

② <②PLUS/MINUS> - Choose one between (+) and (-)

It is relevant to 3 Functions like Ion soft, Ion hard, Ion lift.

③ <④⑤Temperature>- Settle up temp. using UP/DOWN button

COLD -10 ~ +10

HOT +35 ~ +45

④ <⑩Time>- Control time to use / Setting time: 20min

⑤ <⑪START> Start the operation after settle up desired Mode, Temp., Time and check the

ground earth rod

⑥ <②Intensity> Control Output rate and Intensity. Slowly turn the intensity up during the

operation Range of Intensity: Control between 0% & 100%

⑦ <⑪STOP> Pause button. The STOP button works pause function during operation.

⑧ In case only Cryo/Thermo is used without electric stimulation

Choose desired Temp.

Do not use Ground Rod because of no electric stimulation

Page 7: Cryo-derm

CRYO-DERM

7

2. Direction to Use

Direction to use for CH.2 Injection Electrode

CH.1 Cryo/thermo Control Common Control CH.2 Injection Electrode Control

2. Usage of CH.2 Injection Electrode

Start treatment after checking it whether client grip Ground Rod

① <⑥Mode>- Choose one among 5 functions

② <②PLUS/MINUS> - Choose one between (+) and (-)

It is relevant to 3 Functions like Ion soft, Ion hard, Ion lift.

③ <⑨FLOW SPEED>- Control the volume of injection flow depending on formulation of

ampoules

④ <⑩Time>- Control time by using time button /Setting time: 20min.

⑤ <⑪START> Start the operation after settle up desired Mode, Temp., Time and check the

ground earth rod

⑥ <②Intensity> Control Output rate and Intensity. Slowly turn the intensity up during the

operation Range of Intensity: Control between 0% and 100%

⑦ <FOOT SWITCH> Adjust ampoule injection’s flux stepping FOOT SWITCH. The ampoule

only flows while stepping in the switch. It will be started with “PeeP” sound.

⑧ <⑪STOP> Pause button. The STOP button works pause function during operation.

Low Weak

Medium Medium

High Strong

Page 8: Cryo-derm

CRYO-DERM

8

2. Direction to Use

Zero Start Error: If all volumes are not on “Zero” level after you start

the device, you can see the below error massage and warning sound.

So in order to make the device go on, all volume levels are on “Zero”

and then automatically it goes on processing.

After using an injection electrode, the

nozzle could be clogged or have a hygienic

problem because of viscosity of ampoule.

How to work CLEAR Mode: : Proceed the

mode when continue to push “FLOW SPEED”

button for 3 sec.

How to control the nozzle : On the “low” setting and stepping in the food switch, adjust the flow

volume by turning the particle controller. You can adjust the flow setting depending ampoule

density.

Page 9: Cryo-derm

CRYO-DERM

9

2. Direction to Use

How to deal with CRYO_DERM after Use.

1) Clean up the main body with dry cloth.

⋇ Possible to occurs variation of the device when using chemicals

2) Clean up the used cryo/thermo electrode with wet cloth first and then use dry cloth

⋇ Possible to occurs variation of the device when using chemicals

3) Remove remaining ampoule on the used injection electrode by tapping it on other hand

covered dry cloth

Clean up the electrode head with wet cloth first and then use dry cloth.

The remaining ampoule keep clogged in the electrodes until next usage

If you don’t use it for more than one day, use the Clean Mode to clean up inside with cleaning

solution taking off ampoule bottle and then store it.

⋇ Possible to occurs variation of the device when using chemicals and may have a problem with

injection pump unless use clear solution.

4) Cleaned injection is stored at its stand. .

⋇ If the injection is put up-down side, the ampoule would be leaked.

5) Change the water in water tank after using 6 ~ 9 months later.

⋇ If period of change cooling water is long, there is problem with cryo/thermo system by cause

of waste material inside.

Page 10: Cryo-derm

CRYO-DERM

10

3. Features of Cryo_Derm

1) Cryo and Thermo

Cryo_Derm works by thermoelectric semiconductor to make cool and hot. Surface of

semiconductor is cooling when absorbing the heat and heating when exhausting the heating. So

it works in water based exhaust system for the best effectiveness.

Cooling effect helps skin calm and pores minimize and there is double effect of penetrating ion

when use ion function together. Thermo effect helps blood circulation improve and pores enlarge.

2) Ampoule Injection

It is different that Cryo_Derm has automatic built-in ampoule injection than other equipment

which has a problem that a nozzle is clogged often.

The ampoule injection is able to adjust its flux according to viscosity and kind of ampoule by user

friendly, FOOT SWITCH.

3) Iontophoresis

Cryo_Derm’s iontophoresis works by 3.8 KHz medium frequency which penetrates into deep layer

of skin. It is based on the electrical repulsive power to bring more effective penetration of

vitamins, mineral and collagen than cosmetics or ampoules.

4) Ion-Lifting

Using 250Hz, it would make face-lifting effect by stretching in and out with soft ion feeling and

current penetration principle.

5) Lifting Massage

It is focused on skin lifting effect using both poles of 200Hz medium and low frequency.

6) REJUVENATION

It brings rejuvenation and vitalization effect on skin using bioelectricity which exhales from

body when human does exercise.

Page 11: Cryo-derm

CRYO-DERM

11

3. Features of Cryo_Derm

Cryo_Derm is a professional skin care device for those who need professional skin care.

It makes active ampoule applied to skin by using an injection electrode and brings effects

such as skin soothing, contraction and enlargement of pores, improvement of blood

circulation, ion application and ion lifting using a injection electrode.

① Save treatment time by applying ampoule using injection electrode and iontophoresis

simultaneously.

② Maximize iontophoresis’s function using cyro/thermo electrode and improve skin condition

such as skin soothing, contraction and enlargement of pores, improvement of blood circulation.

③ Possible to do treatment two people at the same time.

④ Easy to master in comparison with various functions.

⑤ Be suitable output for individual skin by adjusting fine output

⑥ Possible to control the volume of injection flow according to viscosity and kind of ampoule.

⑦ Possible to use anywhere without special equipment for power supply due to a freeVolt

adaptor built-in.

⑧ Be tailored treatment for individual skin due to various modes.

Page 12: Cryo-derm

CRYO-DERM

12

4. Principle & Effects of Cryoelectrophoresis

Principle of Cryoelectrophoresis

Principle of Cryoelectrophoresis

Cryoelectophoresis makes pores’ sizes enlarged to help to penetrate active ingredients into skin

and then when adding electric stimulation, it is maximized that the active ingredients are

penetrated into deeper layer of skin. Cryoelectrophoresis has much more effective penetration

than general electrophoresis.

Cryogen "Cryoelectrophoresis system"

Cryoelectrophoresis system is called “Ice therapy” that penetrates moisture into skin and

maximizes medicines penetration from Meso Therapy without using injector. It brings visible effect

of the medicines as ionization and physical penetration are combined to maximize its penetration.

Also it has good effects on scalp therapy or edema induced thermal energy and

hyperpigmentation because it is based on cryo therapy not thermal energy.

Ionized vitamin C is penetrated through (-) current because its property is marked cathode.

Page 13: Cryo-derm

CRYO-DERM

13

4. Principle & Effects of Cryoelectrophoresis

Cryo-electrophoresis Cryo-electrophoresis is way to penetrate Ionized fluid into skin by osmotic pressure happened

by electric stimulation. The Electrophoresis which was found in 1808 is an electrokinetic

phenomenon that ionized molecule within an electrolyte is moved by another electrode.

Ion within electrolyte(water-soluble substance) flows one or both ways depending on ion’s

electric charge. Ionized water-soluble solvent is absorbed surface of skin tissues effectively basing

on principle that same electric charges are pushed simultaneously and on the contrary, different

electric charges are pulled.

Ionized solvent which is electrically pushed by ion is absorbed by capillary circulation and

permeation of cell membrane. It is the principle to nourish skin using magnetic property effect.

Iontophoresis is technique using a small electric charge to effectively deliver a medicine, water-

soluble gel or ampoule through the skin. Adding a cooling system, it brings primary effects of

skin protection and soothing and prevents to absorb medicines into blood vessel capillary

contraction.

※ Osmotic Pressure Phenomenon

In Human body, the cell membrane features selectively permeable because osmosis occurs

when there is a partially permeable membrane. The osmotic pressure is defined to be the

pressure required to maintain an equilibrium with no net movement of solvent. It is a colligative

property meaning that the osmotic pressure depends on the molar concentration of the solute

but not on its identity.

Effects of Poles

Cathode Effects of Between Poles Anode

- Alkaline Solution Penetration

- Skin Activation

- Enlargement of Sweat Glands

- Relaxation of Skin Tissues

- Refining Pores

- Improvement of Blood

Circulation

- Stimulation of Nervous system

- Acceleration of Lymph

and Blood Circulation

- Acceleration of

Metabolism

- Increase of Temperature

- Acid Solution Penetration

- Skin Soothing

- Contraction of Sweat Glands

- Strengthening Skin Tissues

- Relief of inflammation

- Reduction of Blood

Circulation

-Relaxation of Nerve

Alkaline Reaction Acid Reaction

Page 14: Cryo-derm

CRYO-DERM

14

5. Application program

1. Post Peeling Treatment to soothe skin

Sequence 1.

Cleansing

2.

Soothing

3. Ampoule

Penetration

5. Soothing 4. Pack 5. Finish

Applicatio

n

1 CH 2 CH

Soft ion

1 CH

Temp. Cold (0) Cold (0)

Polarity (+) ion

Time 5min. 5min. 5min. 5min. 15min. 5min.

2. Skin Whitening Care

Sequence 1.

Cleansing

2.

Circulation

3. Deep

Cleansing

4. Ampoule

Penetration

5. Massage 6. Pack 7. Finish

Application 1 CH

Soft ion

2 CH

Hard ion

1 CH

Rejuvenation

Temp. Hot (40) Cold (-5)

Polarity (-) ion (-) ion

Time 5min. 5min. 5min. 5min. 10min. 15min. 5min.

3. Acne Skin Care

Sequence 1.

Cleansing

2.

Circulation

3. Deep

Cleansing

4. Ampoule

Penetration

5. Massage 6. Pack 7. Finish

Application 1 CH

Soft ion

2 CH

Soft ion

1 CH

Ion MSG

Temp. Hot (40) Cold (-5)

Polarity (-) ion (+) ion

Time 5min. 5min. 5min. 5min. 10min. 15min. 5min.

Page 15: Cryo-derm

CRYO-DERM

15

5. Application program

4. Rejuvenation Treatment for aging skin

Sequence 1.

Cleansin

g

2.

Circulatio

n

3. Deep

Cleansin

g

4. Ampoule

Penetration

5.

Massag

e

6. Pack 7.

Soothing

8.

Finish

Applicatio

n

1 CH

Soft ion

2 CH

Hard ion

1 CH

Rejuven

ation

Cold

(-5)

Temp. Hot (40) Hot

(42)

Polarity (-) ion (-) ion

Time 5min. 5min. 5min. 10 min. 15

min.

5min. 5min.

5. Wrinkle and Skin Elasticity Care

Sequence 1.

Cleansin

g

2.

Circulation

3. Deep

Cleansin

g

4.

Ampoule

Penetratio

n

5.

Massag

e

6. Pack 7.

Soothing

8.

Finish

Applicatio

n

1 CH

Soft ion

2 CH

Hard ion

1 CH

Ion Lift

Cold

(-5)

Temp. Hot (40) Hot

(42)

Polarity (-) ion (+) ion (-) ion

Time 5 min. 5 min. 5 min. 5 min. 10 min. 15 min. 5min. 5

min.

Page 16: Cryo-derm

CRYO-DERM

16

6. Treatment Method

Treatment Method

Facial Treatment (Cryo/Thermo Electrode )

MODE ION SOFT

ION HARD

ION LIFT

ION MSG

REJUVENATION

LEVEL 25%

TIME 10~15min

TEMP COLD -10 ~ +10

HOT +35 ~ +45

Facial Treatment (Injection Electrode)

MODE ION SOFT

ION HARD

ION LIFT

ION MSG

REJUVENATION

LEVEL 25%

TIME 10~15min

FLOW

SPEED

LOW, MIDDUM, HIGH

Page 17: Cryo-derm

CRYO-DERM

17

6. Treatment Method

Facial Treatment

1. Rub down sternocleidomastoid around

neck and finish at armpit.

2. Rub up along chin and finish at terminus.

3. Rub up drawing a circle along chin

4. Draw a circle on mouth, eyes area

separately.

5. Draw a circle on nose and forehead.

6. Rub from decollete to the whole of face

and finish by drainage.

Page 18: Cryo-derm

CRYO-DERM

18

6. Treatment Method

Abdominal Treatment (Cryo/Thermo Electrode)

TEMP COLD -10 ~ +10

HOT +35 ~ +45

1. Draw a circle in a

clockwise direction.

2. Massage on abdomen

drawing diamond finish at

inguinal region.

3. Rub both sides toward the

navel and finish at the

inguinal region.

4. Rub up from side of

abdomen to the navel.

5. Drainage entirely at

inguinal region.

6. Draw a circle in a

clockwise direction.

Page 19: Cryo-derm

CRYO-DERM

19

6. Treatment Methods

Legs Treatment (Cryo/Thermo Electrode)

TEMP COLD -10 ~ +10

HOT +35 ~ +45

1. Rub up gastrocnemius of

calf and thigh entirely.

2. Massage up in zigzag and

drainage toward lymph

area. .

3. Draw a circle and rub

up toward lymph area.

Page 20: Cryo-derm

CRYO-DERM

20

7. Specification

① Dimension: 380 X 490 X 130mm

② Power: DC 12V 6A

③ Weight: 21Kg

④ Output Frequency or Current

- ION HARD 3.8KHz, MAX 35mA

- ION SOFT 3.8KHz, MAX 28mA

- IONLIFT 250Hz, MAX 22mA

- LIFTMSG 200Hz, MAX 25mA

- REJUVENATION 125Hz MAX 4mA

⑤ LORD RESISTANCE: 500Ω

⑥ Range of Temperature

- COOL : 10 ~ -10 1

- HOT: 35 ~ 45 1

⑦ Flow Control: HIGH, MIDDLE, LOW

⑧ Length of Treatment: 5min. ~ 60min.

⑨ Consumption Power

- Stand-by: 0.45A 5.4W

- Poccessing: 2.9A 35W (MAX 3.6A 43W)

⑩ AC Adapter

- Input: AC 100-240V, 1.8A, 50-60Hz

- Output: DC 12V, 6A

⑪ Environment Condition of Application/Storage

- Processing Temperature : 5 ~ 35

- Processing Humidity : RH 60% 이하

- Storage Temperature : 0 ~ 60

- Storage Humidity : RH 80% 이하

⑫ Protective device

- Preventive Circuit for over current (Over current)

- Preventive Circuit for over heat (Over heat)

- Zero start

⋇ Do not use this device for purpose of medical treatment because of it’s not a medical

equipment. *

Page 21: Cryo-derm

CRYO-DERM

21

8. Warranty Information

9. Warranty Information

Cosmo C&T Limited Warranty

What the warranty covers:

Cosmo C&T warrants its products to be free from defects in material and workmanship during the

warranty period. If a product proves to be defective in material or workmanship during the

warranty period, Cosmo C&T will, at its sole option, repair or replace the product with a similar

product. Replacement Product or parts may include remanufactured or refurbished parts or

components. The replacement unit will be covered by the balance of the time remaining on the

customer’s original limited warranty. Cosmo C&T provides no warranty for the product installed by

the customer. Cosmo C&T will report whether we will compensate or not in ten (10) days after

you require and the settlement will be reached within twenty one (21) days after you require.

Who the warranty protects:

This warranty is valid only for the first consumer purchaser.

What the warranty does not cover:

1. Any product on which the serial number has been defaced, modified or removed.

2. Damage, deterioration or malfunction resulting from:

A. Accident, misuse, neglect, fire, water, lightning, or other acts of nature,

unauthorized product modification, or failure to follow instructions supplied with

the product.

B. Repair or attempted repair by anyone not authorized by Cosmo C&T.

C. Damage to or loss of any programs, data or removable storage media.

D. Any damage of the product due to shipment.

E. Removal or installation of the product.

F. Causes external to the product, such as electric power fluctuations or failure.

G. Use of supplies or parts not meeting Cosmo C&T's specifications.

H. Any other cause which does not relate to a product defect.

I. Damage to, or abuse of, the coating on the surface of the display.

3. Removal, installation, and set-up service charges.

Page 22: Cryo-derm

CRYO-DERM

22

8. Warranty Information

How long the warranty is effective:

Cryo_Derm products are warranted for one (1) year for parts and labor.

Types of damages

Warrants

Within the

warranty period

After the

warranty period

When the machine is in need of repair because of

capability trouble or functional defect with normal

operating within ten (10) days after purchase.

Replacement Or

Repair- free of

charge

When the machine is in need of repair because of

capability trouble or functional defect with normal

operating within one (1) month after purchase.

Replacement Or

Repair- free of

charge

Repair -

Possible

3 times break down with the same

problem

Repair- free of

charge

Repair -

compensation

4 times break down with the same

problem

Replacement Repair -

compensation

Repair -

Impossible

Impossible repair with the situation we

have parts for repair (within the term

of the parts holding)

Replacement Replacement

with depreciation

plus 10% of

depreciation

Impossible repair with the situation we

do not have parts for repair (within

the term of the parts holding)

Replacement Replacement

with depreciation

Page 23: Cryo-derm

CRYO-DERM

23

8. Warranty Information

How to get service:

1. For information on obtaining warranty service, call Cosmo C&T's Customer Support

telephone number is: +82-2-338-3789. (Sunny Hwang : [email protected])

2. To obtain warranty service, please contact Cosmo C&T Customer Support. You will be

required to provide

A. A copy of the dated sales slip.

B. Your name.

C. Your address.

D. The serial number of the product.

E. A description of the problem.

3. Bring or ship the product prepaid in the original container, with the associated accessories,

to Cosmo C&T service center.

NOTE: Cosmo C&T is not responsible for any returned product without notice in advance.

Exclusion of damages:

COSMO C&T’S LIABILITY IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE

PRODUCT. COSMO C&T SHALL NOT BE LIABLE FOR:

1. DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE PRODUCT, DAMAGES

BASED UPON INCONVENIENCE, LOSS OF USE OF THE PRODUCT, LOSS OF TIME, LOSS OF

PROFITS, LOSS OF BUSINESS OPPORTUNITY, LOSS OF GOODWILL, INTERFERENCE WITH

BUSINESS RELATIONSHIPS, OR OTHER COMMERCIAL LOSS, EVEN IF ADVISED OF THE

POSSIBILITY OF SUCH DAMAGES.

2. ANY OTHER DAMAGES, WHETHER INCIDENTAL, CONSEQUENTIAL OR OTHERWISE.

3. ANY CLAIM AGAINST THE CUSTOMER BY ANY OTHER PARTY.


Recommended