CS-SIG-01 Definitions and procedures for supervising station signals
Central Station Alarm Association
440 Maple Avenue East, Suite 201
Vienna, VA 22180
Note: This document is a draft.
1. *Scope. The purpose of this document is to provide code handling for industry standard codes for supervising stations. The main category is whether or not the code is critical or non critical. Each category is broken down by code type and its handling instruction is detailed. Each individual code is listed in a table with the handling instructions. Critical Codes1.1. Burglary – Critical
1.1.1. Handling Instruction. The supervising station shall call to verify in accordance to ANSI/CSAA CS-V-01, authority dispatch, responding party and alarm company
1.1.2. These codes could be an actual emergency, therefore by calling to verify it allows the subscriber to cancel or request assistance. If no authorized pass code is obtained when calling to verify or if assistance is requested the authorities will be dispatched accordingly. Followed then by notifying the responding party of the dispatch and advising the alarm company.
1.1.3. Code Table: FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTH
NOTIFY PREM
RPALARM CO.
Ademco Superfast
11 ALARM Y P Y Y
Ademco Superfast
12 ALARM Y P Y Y
Ademco Superfast
13 ALARM Y P Y Y
Ademco Superfast
14 ALARM Y P Y Y
Ademco Superfast
15 ALARM Y P Y Y
Ademco Superfast
16 ALARM Y P Y Y
Ademco Superfast
17 ALARM Y P Y Y
Ademco Superfast
18 ALARM Y P Y Y
AES A ALARM Y P Y Y
CID 134 BURG-ENTRY/EXIT Y P Y Y
CID 130 BURGLARY Y P Y Y
CID 140 GENERAL ALARM Y P Y Y
CID 145 MODULE TAMPER EXPANSION Y P Y Y
CID 141 POLLING LOOP OPEN ALARM Y P Y Y
CID 142 POLLING LOOP SHORT ALARM Y P Y Y
CID 144 SENSOR TAMPER ALARM Y P Y Y
CID 146 SILENT BURGLARY Y P Y Y
DMP A0 ALARM BLANK Y P Y Y
DMP S42 ALARM: BURGLARY ZONE ALARM OVERFLOW Y P Y Y
DMP S74 ALARM: TAMPER DURING ARMED STATE Y P Y YDMP S79 ALERT: SIGNAL DURING OPEN PERIOD Y P Y YDMP S77 ALERT: UNAUTHORIZED ENTRY Y P Y YDMP A6 AUXILIARY 1 Y P Y YDMP AA1 AUXILIARY 1 Y P Y YDMP A7 AUXILIARY 2 Y P Y YDMP AA2 AUXILIARY 2 Y P Y Y
ITI A ALARM Y P Y Y
CSAA Scope for Handling, edited Page 1 of 30 4/7/2023
ITI A92 ALARM / TAMPER LOOP Y P Y Y
ITI A79 ALARM! NO ACTIVITY Y P Y Y
ITI D DIALOUT AUDIO ALARM Y P Y Y
ITI T TAMPER Y P Y Y
ITI A77 TOUCHPAD TAMPER Y P Y Y
ITI SX A104 ALARM! MANUAL POLICE Y P Y Y
ITI SX A ALARM Y P Y Y
ITI SX A100 ALARM! BUDDY SYSTEM! Y P Y Y
ITI SX A113 ALARM! TAMPER LOOP! Y P Y Y
ITI SX A101 ALARM! TOUCHPAD TAMPER! Y P Y Y
ITI SX T TAMPER Y P Y YMODEM 4112 & 6113 1 ALARM Y P Y Y
MODEM 4112 & 6114 7 ALARM Y P Y Y
MODEM 4112 & 6115 8 USER ALARM Y P Y Y
MODEM 8113
1 ALARM Y P Y Y
MODEM 8114
7 ALARM Y P Y Y
MODEM 8115
B ALARM Y P Y Y
MODEM III 10 ALARM REPORT Y P Y Y
MODEM III 13 MISSING ALARM Y P Y Y
MODEM III 09 S: ALARM Y P Y Y
MODEM III 05 USER ALARM CMD 7 Y P Y YMODEM III 06 USER ALARM CMD 9 Y P Y YRADIONICS UX UNDEFINED ALARM Y P Y YSIA AA ALARM-PANEL SUBSTITUTION Y P Y Y
SIA BA BURGLARY ALARM Y P Y Y
SIA TA TAMPER ALARM Y P Y Y
SIA BG UNVERIFIED EVENT-BURGLARY Y P Y Y
SIA UX UNDEFINED ALARM Y P Y Y
SIA JA USER CODE TAMPER Y P Y Y
1.2. Burglary – Critical 1.2.1. Handling Instruction. The supervising station shall notify premise, responding
party and alarm company1.2.2. The premises shall receive notification of the signal, followed by the responding
party and the alarm company.1.2.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 353 LONG RANGE RADIO XMITTER FAULT Y Y YITI V INSTANT AUDIO Y Y YITI A99 LATCHKEY Y Y YITI G ONE RING AUDIO ALARM Y Y YITI SX D DIALOUT AUDIO ALARM Y Y YITI SX V INSTANT AUDIO Y Y YSIA BV BURGLARY VERIFIED Y Y YSIA EA EXIT ALARM Y Y Y
SIA ES EXPANSION DEVICE TAMPER Y Y Y
SIA XM MISSING ALARM-CROSS POINT Y Y Y
SIA CR RECENT CLOSING Y Y Y
1.3. Fire – Critical1.3.1. Handling Instruction. The supervising station shall notify the proper authorities,
responding party, alarm company.
CSAA Scope for Handling, edited Page 2 of 30 4/7/2023
1.3.2. These codes could be actual emergencies; therefore, by immediately dispatching the authorities immediate action is taken. Followed then by notifying the premise and responding parties of the dispatch, then advising the alarm company. Code Table:
1.3.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 162 CARBON MONOXIDE DETECTED F Y Y YCID 110 FIRE F Y Y YCID 112 FIRE/COMBUSTION F Y Y YCID 116 FIRE/DUCT F Y Y YCID 117 FIRE/FLAME F Y Y YCID 114 FIRE/HEAT F Y Y YCID 118 FIRE/NEAR ALARM F Y Y YCID 115 FIRE/PULL STATION F Y Y YCID 111 FIRE/SMOKE F Y Y YCID 373 FIRE TROUBLE F Y Y YCID 113 FIRE/WATERFLOW F Y Y YCID 151 GAS DETECTED F Y Y YDMP A1 FIRE F Y Y YDMP AFI FIRE F Y Y YDMP T1 FIRE TROUBLE F Y Y YDMP TFI TROUBLE FIRE F Y Y Y
DMP W44WARNING: FIRE-BURGLARY TROUBLE OVERFLOW
F Y Y Y
DMP S40 ALARM: FIRE ZONE ALARM OVERFLOW F Y Y YITI SX A103 ALARM! MANUAL FIRE! F Y Y YMODEM II 0B FIRE ALARM F Y Y Y
MODEM II 7B FIRE SUPRV FAIL F Y Y Y
MODEM II 7D FIRE SUPRV TROUBLE F Y Y Y
MODEM II 0C FIRE TROUBLE F Y Y Y
MODEM II 0D MISSING FIRE F Y Y YMODEM II 92 MISSING FIRE SUPRV F Y Y YMODEM II 85 S: FIRE ALARM F Y Y YMODEM II 8D S: FIRE MISSING F Y Y YMODEM II 80 S: FIRE SUPERVISION F Y Y YMODEM II 94 S: MISSING FIRE SUPRV F Y Y YRADIONICS FA FIRE F Y Y YRADIONICS GA GAS ALARM F Y Y YRADIONICS KA FIRE / HEAT ALARM F Y Y YRADIONICS SA FIRE / SPRINKLER ALARM F Y Y YRADIONICS FT FIRE TROUBLE F Y Y YRADIONICS FY MISSING FIRE TROUBLE F Y Y YRADIONICS KT HEAT TROUBLE F Y Y YRADIONICS ST SPRINKLER TROUBLE F Y Y YSIA FA FIRE ALARM F Y Y YSIA FM FIRE ALARM-CROSS POINT F Y Y Y
SIA FW FIRE SUPERVISORY TROUBLE Y Y Y Y
SIA KT HEAT TROUBLE Y Y Y Y
SIA FZ MISSING FIRE SUPERVISION Y Y Y Y
SIA FY MISSING FIRE TROUBLE Y Y Y Y
SIA FT FIRE TROUBLE Y Y Y Y
SIA GA GAS ALARM F Y Y YSIA KA HEAT ALARM F Y Y YSIA SA SPRINKLER ALARM F Y Y YSIA FG UNVERIFIED EVENT-FIRE F Y Y Y
1.4. Fire – Critical1.4.1. Handling Instruction. The supervising station shall notify premises, responding
party, alarm company.1.4.2. These codes are not necessarily emergencies; however, the premises, responding
parties an alarm company shall be aware of the signals.
CSAA Scope for Handling, edited Page 3 of 30 4/7/2023
1.4.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 200 FIRE SUPERVISORY Y Y YCID 155 FOIL BREAK TROUBLE Y Y YCID 203 GATE VALVE SENSOR Y Y YCID 310 GROUND FAULT Y Y YCID 158 HIGH TEMPERATURE Y Y YCID 161 LOSS OF AIR FLOW Y Y YCID 153 LOSS OF HEAT Y Y YCID 157 LOW BOTTLE GAS LEVEL Y Y YCID 202 LOW CO2 Y Y YCID 571 FIRE BYPASS Y Y YCID 604 FIRE TEST Y Y YCID 373 FIRE TROUBLE Y Y YCID 614 FIRE ZONE WALK TESTED Y Y YCID 385 SMOKE HI SENS. Y Y YCID 386 SMOKE LO SENS. Y Y YDMP B1 FORCE ARM FIRE Y Y YDMP BFI ZONE FORCE FIRE Y Y Y
DMP HBU WIRELESS ZONE BURG MISSING Y Y Y
DMP H2 XMTR MISSING BURLARY Y Y Y
DMP R1 RESTORE/FIRE Y Y YDMP RFI RESTORE FIRE Y Y YDMP X1 BYPASS FIRE Y Y YDMP Y1 RESET FIRE Y Y YDMP YFI RESET FIRE Y Y YITI SX R103 MANUAL FIRE CANCELED Y Y YMODEM II 0E FIRE RESTORE Y Y YMODEM II 0F FIRE RESTORE Y Y YMODEM II 7C FIRE SUPERVISION Y Y YMODEM II 25 FIRE WALK END Y Y YMODEM II 24 FIRE WALK START Y Y Y
RADIONICS BS BURGLARY SUPERVISORY Y Y Y
RADIONICS FB FIRE BYPASS Y Y YRADIONICS FH FIRE ALARM RESTORE Y Y YRADIONICS FR FIRE RESTORE Y Y YRADIONICS FS FIRE SUPERVISORY Y Y YRADIONICS FU FIRE UNBYPASS Y Y YRADIONICS GB GAS BYPASS Y Y YRADIONICS GH GAS ALARM RESTORE Y Y YRADIONICS GS SUPERVISORY Y Y YRADIONICS GU GAS UNBYPASS Y Y YRADIONICS KB HEAT BYPASS Y Y YRADIONICS KH HEAT ALARM RESTORE Y Y YRADIONICS KR HEAT RESTORAL Y Y YRADIONICS KS HEAT SUPERVISORY Y Y YRADIONICS KU HEAT UNBYPASS Y Y YRADIONICS SB SPRINKLER BYPASS Y Y YRADIONICS SH SPRINKLER ALARM RESTORE Y Y YRADIONICS SS SPRINKLER SUPERVISORY Y Y YRADIONICS SU SPRINKLER UNBYPASS Y Y YSIA FH FIRE ALARM RESTORE Y Y YSIA FL FIRE ALARM SILENCED Y Y YSIA FB FIRE BYPASS Y Y YSIA FC FIRE CANCEL Y Y YSIA FR FIRE RESTORAL Y Y YSIA FV FIRE SUPERVISION RESTORE Y Y YSIA FS FIRE SUPERVISORY Y Y YSIA FU FIRE UNBYPASS Y Y YSIA GH GAS ALARM RESTORE Y Y YSIA GB GAS BYPASS Y Y YSIA GR GAS RESTORAL Y Y YSIA GS GAS SUPERVISORY Y Y YSIA GU GAS UNBYPASS Y Y Y
CSAA Scope for Handling, edited Page 4 of 30 4/7/2023
SIA KH HEAT ALARM RESTORE Y Y YSIA KB HEAT BYPASS Y Y YSIA KR HEAT RESTORAL Y Y YSIA KS HEAT SUPERVISORY Y Y YSIA KU HEAT UNBYPASS Y Y Y
1.5. Medical – Critical1.5.1. Handling Instruction. The supervising station shall call to verify, authority
dispatch, responding party and alarm company.
1.5.2. These codes could be an actual emergency, therefore by calling to verify it allows the subscriber to cancel or request assistance. If no authorized pass code is obtained when calling to verify or if assistance is requested the authorities will be dispatched accordingly. Followed then by notifying the responding party of the dispatch and advising the alarm company.
1.5.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 100 MEDICAL Y M Y Y
CID 101 PENDANT TRANSMITTER Y M Y Y
RADIONICS MA MEDICAL ALARM Y M Y Y
SIA MA MEDICAL ALARM Y M Y Y
1.6. Panic – Critical1.6.1. Handling Instruction. Authority dispatch, responding party, alarm company.1.6.2. These codes could be actual emergency situations that require immediate
attention from the authorities. Followed then by notifying the responding party and then alarm company.
1.6.3. Code Table:FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTH
NOTIFY PREM
RPALARM CO.
CID 123 AUDIBLE PANIC P Y Y
CID 120 PANIC P Y Y
CID 122 SILENT PANIC P Y Y
ITI A81 ALARM! MANUAL POLICE P Y Y
Radionics PA PANIC ALARM P Y Y
Radionics QA EMERGENCY ALARM P Y Y
SIA QA EMERGENCY ALARM P Y Y
SIA HA HOLDUP ALARM P Y Y
SIA PA PANIC ALARM P Y Y
SIA UA UNTYPED ZONE ALARM P Y Y
1.7. Duress – Critical1.7.1. Handling Instruction. Authority dispatch, responding party, alarm company.1.7.2. These codes could be actual emergency situations that require immediate
attention from the authorities. Followed then by notifying the responding party and then alarm company.
1.7.3. Code Table:FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTH
NOTIFY PREM
RPALARM CO.
Ademco Superfast
1 DURESS P Y Y
CID 121 DURESS P Y Y
CID 124 DURESS-ACCESS GRANTED P Y Y
CID 125 DURESS-EGRESS GRANTED P Y Y
CSAA Scope for Handling, edited Page 5 of 30 4/7/2023
DMP S15 AMBUSH P Y Y
DMP S41 ALARM: PANIC ZONE ALARM OVERFLOW P Y Y
ITI A86 ALARM! SILENT DURESS P Y YMODEM 4112 & 6113 9 DURESS P Y Y
MODEM III 04 DURESS P Y Y
SIA HA HOLDUP ALARM P Y Y
2. Supervisory - Non Critical Codes
2.1. Burglary – Supervisory– Non Critical Codes2.1.1. Handling Instruction. Alarm company2.1.2. These codes are non-emergency; however, the alarm company shall be informed
of the transmission2.1.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 573 BURGLARY BYPASS Y
DMP A3 ALARM SUPERVISORY Y
DMP B2 FORCE ARM BURGLARY Y
DMP BBU ZONE FORCE BURGLARY Y
DMP XBU BURGLARY BYPASS BY ZONE Y
DMP Y2 RESET BURGLARY Y
DMP YBU RESET BURGLARY Y
DMP RBU RESTORE BURGLARY Y
DMP R2 RESTORE/BURG Y
ITI SX R104 MANUAL POLICE CANCELED Y
RADIONICS BH BURGLARY ALARM RESTORE Y
RADIONICS BB BURGLARY BYPASS Y
RADIONICS BC BURGLARY CANCEL Y
RADIONICS BU BURGLARY UNBYPASS Y
SIA BM BURGLARY ALARM CROSS POINT Y
SIA BH BURGLARY ALARM RESTORE Y
SIA BB BURGLARY BYPASS Y
SIA BC BURGLARY CANCEL Y
SIA BR BURGLARY RESTORAL Y
SIA BS BURGLARY SUPERVISORY Y
SIA BU BURGLARY UNBYPASS Y
2.2. Medical –Supervisory –Non Critical Codes2.2.1. Handling Instruction. Alarm company2.2.2. These codes are non-emergency; however, the alarm company shall be
informed of the transmission2.2.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
RADIONICS MB MEDICAL BYPASS Y
RADIONICS MH MEDICAL ALARM RESTORE Y
RADIONICS MJ MEDICAL TROUBLE RESTORE Y
RADIONICS MR MEDICAL RESTORE Y
RADIONICS MU MEDICAL UNBYPASS Y
SIA MH MEDICAL ALARM RESTORE Y
SIA MB MEDICAL BYPASS Y
CSAA Scope for Handling, edited Page 6 of 30 4/7/2023
SIA MR MEDICAL RESTORE Y
SIA MU MEDICAL UNBYPASS Y
2.3. Medical –Supervisory –Non Critical Codes2.3.1. Handling Instruction. The supervising station shall notify premises, responding
parties and alarm company2.3.2. These codes are non-emergency; however, the premises, responding parties and
alarm company shall be informed of the transmissions.2.3.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
RADIONICS MS MEDICAL SUPERVISORY Y Y YSIA MS MEDICAL SUPERVISORY Y Y Y
2.4. Panic –Supervisory – Non Critical Codes2.4.1. Handling Instruction. Alarm company2.4.2. These codes are non-emergency; however, the alarm company shall be informed
of the transmission2.4.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 465 PANIC ALARM RESET Y
DMP B4 FORCE ARM PANIC Y
DMP B5 FORCE ARM EMERGENCY Y
DMP BEM ZONE FORCE EMERGENCY Y
DMP BPN ZONE FORCE PANIC Y
DMP X4 BYPASS PANIC Y
DMP XEM EMERGENCY BYPASS BY ZONE Y
DMP XPN PANIC BYPASS BY ZONE Y
DMP Y4 RESET PANIC Y
DMP Y5 RESET EMERGENCY Y
DMP YEM RESET EMERGENCY Y
DMP YPN RESET PANIC Y
DMP X5 BYPASS EMERGENCY Y
DMP R4RESTORE/PANIC not consistent with other restore procedures in previous sections.
Y
DMP R5 RESTORE/EMERGENCY Y
DMP REM RESTORE EMERGENCY Y
DMP RPN RESTORE PANIC Y
Radionics PB PANIC BYPASS Y
Radionics PH PANIC ALARM RESTORE Y
Radionics PU PANIC UNBYPASS Y
Radionics QB EMERGENCY BYPASS Y
Radionics QH EMERGENCY ALARM RESTORE Y
Radionics PR PANIC RESTORE Y
Radionics QR EMERGENCY RESTORE Y
Radionics QU EMERGENCY UNBYPASS Y
SIA HH HOLDUP ALARM RESTORE Y
SIA HB HOLDUP BYPASS Y
SIA HR HOLDUP RESTORE Y
SIA HU HOLDUP UNBYPASS Y
SIA JH HOLIDAY CHANGED Y
SIA PH PANIC ALARM RESTORE Y
SIA PB PANIC BYPASS Y
SIA PR PANIC RESTORE Y
CSAA Scope for Handling, edited Page 7 of 30 4/7/2023
SIA PU PANIC UNBYPASS Y
2.5. Panic –Supervisory – Non Critical Codes2.5.1. Handling Instruction. The supervising station shall notify premises and alarm
company2.5.2. These codes are non-emergency; however, the premises and alarm company shall be informed of the transmission2.5.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
DMP D4 XMTR LOW BATTERY PANIC Y Y
DMP H4 XMTR MISSING PANIC Y Y
DMP H5 XMTR MISSING EMERGENCY Y Y
DMP HEM WIRELESS ZONE MISSING EMERGENCY Y Y
DMP HPN WIRELESS ZONE MISSING PANIC Y Y
2.6. Panic –Supervisory – Non Critical Codes2.6.1. Handling Instruction. The supervising station shall notify premises, responding
parties and alarm company.2.6.2. These codes are non-emergency; however, the premises, responding parties and alarm company shall be informed of the transmission2.6.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
Radionics PS PANIC SUPERVISORY Y Y YRadionics QS EMERGENCY SUPERVISORY Y Y YSIA HS HOLDUP SUPERVISORY Y Y YSIA PS PANIC SUPERVISORY Y Y Y
2.7. Duress – Supervisory – Non Critical Codes2.7.1. Handling Instruction. The supervising station shall notify the alarm company2.7.2. These codes are non-emergency; however, the alarm company shall be informed
of the transmission2.7.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
DMP R0 RESTORE/BLANK Y
SIA HB HOLDUP BYPASS Y
SIA HH HOLDUP ALARM RESTORE Y
SIA HR HOLDUP RESTORAL Y
SIA HU HOLDUP UNBYPASS Y
2.8. Duress – Supervisory – Non Critical Codes2.8.1. Handling Instruction. The supervising station shall notify premises, responding
parties and alarm company2.8.2. These codes are non-emergency; however, the premises, responding parties and alarm company shall be informed of the transmission2.8.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
SIA HS HOLDUP SUPERVISORY Y Y Y
2.9. Other Supervisory – Non Critical Codes 2.9.1. Handling Instruction. The supervising station shall notify the alarm company
CSAA Scope for Handling, edited Page 8 of 30 4/7/2023
2.9.2. These codes are non-emergency; however, the alarm company shall be informed of the transmission
2.9.3. Code Table:FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTH
NOTIFY PREM
RPALARM CO.
ADEMCO SUPERFAST
3 RESTORE Y
AES Y-804 A TO D CONVERTER FAULTED-TEST ZONES YAES A-000 AUTOMATIC SUPERVISORY CHECK-IN YAES T-903 COMMUNICATION TIME-OUT CONDITION YAES T-902 POWER ON RESET – we log Y
AES ST-902POWER ON RESET REPORTED DURING CHECK -IN
Y
AES ST-904PRIOR AC LOSS REPORTED DURING CHECK-IN
Y
AES SAPRIOR ALARM ZONE STILL ACTIVE DURING STATUS REPORT
Y
AES SA-801PRIOR DIAGNOSTIC FAULT CODE DURING STATUS REPORT
Y
AES SA-802PRIOR DIAGNOSTIC FAULT CODE DURING STATUS REPORT
Y
AES SA-803PRIOR DIAGNOSTIC FAULT CODE DURING STATUS REPORT
Y
AES SA-804PRIOR DIAGNOSTIC FAULT CODE DURING STATUS REPORT
Y
AES SA-805PRIOR DIAGNOSTIC FAULT CODE DURING STATUS REPORT
Y
AES SA-806PRIOR DIAGNOSTIC FAULT CODE DURING STATUS REPORT
Y
AES SA-807PRIOR DIAGNOSTIC FAULT CODE DURING STATUS REPORT
Y
AES SA-808PRIOR DIAGNOSTIC FAULT CODE DURING STATUS REPORT
Y
AES SA-809PRIOR DIAGNOSTIC FAULT CODE DURING STATUS REPORT
Y
AES R RESTORE Y
AES ST-901WATCHDOG RESET REPORTED DURING CHECK-IN
Y
AES T-901 WATCHDOG/PUSHBUTTON RESET YCID 301 AC LOSS YCID 421 ACCESS DENIED YCID 426 ACCESS DOOR PROPPED OPEN YCID 434 ACCESS DSM SHUN YCID 577 ACCESS POINT BYPASS YCID 427 ACCESS POINT DSM TROUBLE YCID 429 ACCESS PROGRAM MODE ENTRY YCID 430 ACCESS PROGRAM MODE EXIT YCID 501 ACCESS READER DISABLE YCID 432 ACCESS RELAY/TRIGGER FAIL YCID 433 ACCESS RTE SHUNT YCID 632 ACCESS SCHEDULE CHANGE YCID 431 ACCESS THREAT LEVEL CHANGE YCID 576 ACCESS ZONE SHUNT YCID 610 AUTO ARM YCID 573 BURGLARY BYPASS YCID 406 CANCEL BY USER YCID 527 DISABLE-NOTIFICATION APPL.CKT #4 YCID 526 DISABLE-NOTIFICATION APPL.CKT#3 YCID 412 DOWNLOAD SUCCESSFUL YCID 413 DOWNLOAD UNSUCCESSFUL YCID 424 EGRESS DENIED YCID 425 EGRESS GRANTED YCID 313 ENGINEER RESET YCID 620 EVENT LOG YCID 622 EVENT LOG 50% FULL YCID 623 EVENT LOG 90% FULL YCID 624 EVENT LOG OVERFLOW YCID 621 EVENT LOG RESET Y
CSAA Scope for Handling, edited Page 9 of 30 4/7/2023
CID 574 GROUP BYPASS YCID 442 KEYSWITCH ARMED STAY YCID 462 LEGAL CODE ENTRY ACCESS YCID 606 LISTEN IN TO FOLLOW YCID 393 MAINTENANCE ALERT YCID 312 POWER SUPPLY OVERCURRENT YCID 627 PROGRAM MODE ENTRY YCID 628 PROGRAM MODE EXIT YCID 408 QUICK ARM YCID 407 REMOTE ARM Y
CID R407 REMOTE DISARM Y
CID 553 REMOTE UPLOAD/DOWNLOAD YCID 525 REVERSING RELAY DISABLE YCID 325 REVERSING RELAY TROUBLE YCID 344 RF RCVR JAM DETECT # YCID 630 SCHEDULE CHANGE YCID 466 SERVICE PREMISES YCID 616 SERVICE REQUESTED YCID 605 STATUS REPORT TO FOLLOW YCID 416 SUCCESSFUL UPLOAD YCID 575 SWINGER BYPASS YCID 422 USER ACCESS GAINED YCID 609 VIDEO XMTR ACTIVE YCID 461 WRONG ENTRY CODE ACCESS YCID 570 ZONE/SENSOR BYPASS YDMP S45 ABORT SIGNAL RECEIVED YDMP S00 AC POWER RESTORED YDMP EAD ADD EQUIPMENT YDMP EAJ ADJUST EQUIPMENT YDMP S35 ALARM BELL RETURNED TO NORMAL YDMP S20 ALARM: CARRIER LOCKED ON LINE YDMP S58 ALARM: PANEL SUBSTITUTION YDMP S95 ALERT: ACTIVITY CHECK DISABLED YDMP S94 ALERT: ACTIVITY CHECK ENABLED YDMP S78 ALERT: SYSTEM RECENTLY ARMED YDMP C ARMED YDMP S27 AUXILIARY FUSE RESTORED YDMP S04 BACK UP COMMUNICATION LINE YDMP S39 BELL CIRCUIT RESTORED YDMP S53 BELL FUSE RESTORED YDMP X6 BYPASS AUXILIARY 1 YDMP X7 BYPASS AUXILIARY 2 YDMP X0 BYPASS BLANK YDMP X3 BYPASS SUPERVISORY YDMP S22 CARRIER OFF, MULTIPLEX LINE RESTORED YDMP S02 COMMUNICATION LINE LEVEL RESTORED YDMP S56 CONTROL PANEL TRAPPED-CONNECT NOW YDMP S81 DDMX-CONNECT YDMP S82 DDMX-DISCONNECT YDMP S85 DDMX-REDUNDANT YDMP O DISARMED YDMP JAA DOOR ACCESS DENIED: ARMED AREA YDMP JIT DOOR ACCESS DENIED: INVAILD TIME YDMP JIA DOOR ACCESS DENIED: INVALID AREA YDMP JIC DOOR ACCESS DENIED: INVALID CODE YDMP JIL DOOR ACCESS DENIED: INVALID LEVEL YDMP JAP DOOR ACCESS DENIED: PREVIOUS ACCESS YDMP JDA DOOR ACCESS GRANTED YDMP S70 END OF HISTORY BUFFER YDMP F6 FAIL AUXILIARY 1 YDMP F7 FAIL AUXILIARY 2 YDMP F0 FAIL BLANK YDMP F3 FAIL SUPERVISORY YDMP W6 FAULT AUXILIARY 1 YDMP WA1 FAULT AUXILIARY 1 YDMP W7 FAULT AUXILIARY 2 Y
CSAA Scope for Handling, edited Page 10 of 30 4/7/2023
DMP WA2 FAULT AUXILIARY 2 YDMP W0 FAULT BLANK YDMP WBL FAULT BLANK YDMP W3 FAULT SUPERVISORY YDMP WSV FAULT SUPERVISORY YDMP B6 FORCE ARM AUXILIARY 1 YDMP B7 FORCE ARM AUXILIARY 2 YDMP B0 FORCE ARM BLANK YDMP B3 FORCE ARM SUPERVISORY YDMP S55 INTERNAL MESSAGE– YDMP K0 VERIFY YDMP K1 VERIFY YDMP K2 VERIFY YDMP K3 VERIFY YDMP K4 VERIFY YDMP K5 VERIFY YDMP K6 VERIFY YDMP K7 VERIFY YDMP DSV LOW BATTERY SUPERVISORY YDMP S57 MESSAGE PENDING-PLEASE DISCONNECT YDMP S05 PANEL GROUND RESTORED YDMP S17 PANEL RESPONSE RESTORED YDMP S03 PANEL TAMPER RESTORED YDMP LPE PERMANENT SCHEDULE YDMP N PERMANENT SCHEDULE CHANGE YDMP LPR PRIMARY SCHEDULE YDMP S84 REMOTE COMMAND RECEIVED YDMP S83 REMOTE PROGRAMMING COMPLETE YDMP ERM REMOVE EQUIPMENT YDMP ERP REPAIR EQUIPMENT YDMP ERL REPLACE EQUIPMENT YDMP S71 REQUEST FOR RECEIVER TIME AND DATE YDMP Y6 RESET AUXILIARY 1 YDMP YA1 RESET AUXILIARY 1 YDMP Y7 RESET AUXILIARY 2 YDMP YA2 RESET AUXILIARY 2 YDMP Y0 RESET BLANK YDMP YBL RESET BLANK YDMP YO RESET BLANK YDMP Y3 RESET SUPERVISORY YDMP YSV RESET SUPERVISORY YDMP RA1 RESTORE AUXILIARY 1 YDMP RA2 RESTORE AUXILIARY 2 YDMP RBL RESTORE BLANK YDMP RSV RESTORE SUPERVISORY YDMP R6 RESTORE/AUXILIARY 1 YDMP R7 RESTORE/AUXILIARY 2 YDMP R3 RESTORE/SUPERVISORY YDMP S98 SCS-1 MEMORY FULL YDMP S25 SCS1 POWER UP SIGNAL RECEIVED YDMP LSE SECONDARY SCHEDULE YDMP I SECONDARY SCHEDULE CHANGE Y
DMP S37SECURITY INFORMATION MANAGEMENT STARTUP
Y
DMP S52 SIGNAL DISABLED BY OPERATOR YDMP S01 STANDBY BATTERY RESTORED YDMP S99 SYSTEM CHECK YDMP S96 SYSTEM MESSAGE 96 YDMP S97 SYSTEM MESSAGE 97 YDMP S29 TELEPHONE LINE 1 RESTORE YDMP S31 TELEPHONE LINE 2 RESTORED YDMP LTE TEMPORARY SCHEDULE YDMP S36 TIME/DATE SET BY OPERATOR YDMP UAD USER CODE ADDED YDMP UCH USER CODE CHANGED YDMP UDE USER CODE DELETED YDMP KO VERIFY/BLANK Y
CSAA Scope for Handling, edited Page 11 of 30 4/7/2023
DMP FSV WALK TEST FAIL SUPERVISORY YDMP KSV WALK TEST ZONE VERIFY SUPERVISORY YDMP BA1 ZONE FORCE AUXILIARY 1 YDMP BA2 ZONE FORCE AUXILIARY 2 YDMP BBL ZONE FORCE BLANK YDMP BSV ZONE FORCE SUPERVISORY YDMP S46 ZONE SWINGER AUTOMATICALLY BYPASSED YDMP S47 ZONE SWINGER AUTOMATICALLY RESET YITI S87 AUTO ARMED YITI A98 AUTO EVENT DUMP YITI B BYPASS YITI R CANCEL YITI A95 CPU BACK IN SERVICE YITI W91 CPU BATTERY RESTORAL YITI A91 CPU SHUT DOWN YITI A87 FORCED ARMED YITI W RESTORE YITI J78 RESTORE / FREEZE YITI SX A111 AC POWER FAILURE YITI SX S111 AC POWER RESTORED – YITI SX S110 AUTO ARMED – YITI SX B BYPASS YITI SX R CANCEL – YITI SX A110 FORCED ARMED – YITI SX I IMPROPER SECURITY CODE – YITI SX A116 PANEL BACK IN SERVICE – YITI SX A119 PROGRAM CHANGE – YITI SX W RESTORE – YITI SX R113 TAMPER LOOP CANCELED – YITI SX W113 TAMPER LOOP RESTORAL – YMODEM 4112 & 6110
5 CANCEL – Y
MODEM 4112 & 6111
A DIAGNOSTIC – Y
MODEM 4112 & 6112
4 RESTORE – Y
MODEM 8109
5 CANCEL – Y
MODEM 8110
D CANCEL – Y
MODEM 8111
4 RESTORE – Y
MODEM 8112
A SHUNTED – Y
MODEM III AB ABORT BY USER – YMODEM III 49 AC RESTORE – YMODEM III 73 ACCESS DENIED – YMODEM III 03 ACCESS GRANTED – YMODEM III B1 ALARM PNL SUBST – YMODEM III B0 ALARM SILENCED – YMODEM III A1 ANALOG RESTORE – YMODEM III A0 ANALOG SERVICE – YMODEM III 4C BATTERY RESTORE – YMODEM III AF BYPASS RESTORE – YMODEM III 2D CANCEL ALARM – YMODEM III 6E CARD ASSIGNED – YMODEM III 6F CARD DELETED – YMODEM III 43 COMM RESTORE – YMODEM III A5 CUSTOM FUNCTION YMODEM III 70 CYCLE DOOR – YMODEM III 3B DATE CHANGED YMODEM III 91 DOOR YMODEM III 74 DOOR LEFT OPEN – YMODEM III 91L DOOR LOCKED – YMODEM III 72 DOOR SECURE – YMODEM III 91U DOOR UNSECURE – YMODEM III 74R DR LEFT OPEN RESTORE – YMODEM III 55 F CLOSE PR DELAY – Y
CSAA Scope for Handling, edited Page 12 of 30 4/7/2023
MODEM III 54 F CLOSE PR INST – YMODEM III 08 FORCE POINT – YMODEM III 3D LEVEL CHANGE – YMODEM III 35 LOG OVERFLOW – YMODEM III 34 LOG THRESHOLD – YMODEM III A7 LOW TEMPR RESTORE – YMODEM III 78 NETWORK COND – YMODEM III 77 NETWORK RESTORE– YMODEM III 36 PARAMS CHANGED – YMODEM III 59 PERM DELAY ARMED – YMODEM III 58 PERM INST ARMED – YMODEM III 45 PHONE RESTORE – YMODEM III 07 POINT BYPASS – YMODEM III 3E PROG ACCESS OK – YMODEM III 5A PT USE CODE DELETE – YMODEM III 5B PT USER CODE RESTORE – YMODEM III 40 RAM ACCESS OK – YMODEM III 83 RCVR TAMPER – YMODEM III 84 RCVR TAMPER RESTORE – YMODEM III 52 RE-BOOT – YMODEM III 21 RELAY RESET – YMODEM III 20 RELAY SET – YMODEM III 4F REMOTE RESET – YMODEM III 75 REQUEST TO – YMODEM III 75E REQUEST TO ENTER – YMODEM III 75X REQUEST TO EXIT – YMODEM III 1B RESET – YMODEM III 1A RESTORE FRM ALARM – YMODEM III 12 RESTORE REPORT – YMODEM III 5E RF BATTERY RESTORE YMODEM III 67 RF INTERFERENCE – YMODEM III 87 RF INTERFERENCE RST – YMODEM III 66 RF RCVR RESTORE YMODEM III A2 S: ANALOG SERVICE YMODEM III 90 S: DOOR FORCED YMODEM III 96 S: DOOR LEFT OPEN YMODEM III 8E S: MISSING ALARM YMODEM III 95 S: MISSING SUPRV. YMODEM III 57 S: PERIM DELAY YMODEM III 56 S: PERIM INST YMODEM III 88 S: RF BATTERY LOW YMODEM III 7A S: SUPERVISION YMODEM III 47 SDI RESTORE YMODEM III 1F SENSOR RESET – YMODEM III 8C SENSOR RESTORE – YMODEM III 1E SERVICE END – YMODEM III 1D SERVICE POINT START – YMODEM III AC SERVICE REQUEST – YMODEM III 3A SKED CHANGED – YMODEM III 39 SKED EXECUTED – YMODEM III 01 START LISTEN IN – YMODEM III 23 STATUS REPORT – YMODEM III 5C SWINGER BYPASS – YMODEM III 5F TAMPER RESTORE – YMODEM III 3C TIME CHANGED – YMODEM III 71 UNLOCK DOOR – YMODEM III A9 UNVERIFIED EVENT YMODEM III 1C USER CODE ADDED – YMODEM III 38 USR CODE CHANGE– YMODEM III 22 WAS FORCE ARMED– YMODEM III 2AN WATCH MMODE END– YMODEM III 2AS WATCH MODE START– YMODEM III 4D WATCHDOG RESET– YRADIONICS AR AC RESTORE– YRADIONICS DC ACCESS CLOSED– YRADIONICS DD ACCESS DENIED– YRADIONICS DG ACCESS GRANTED– Y
CSAA Scope for Handling, edited Page 13 of 30 4/7/2023
RADIONICS DK ACCESS LOCKOUT– YRADIONICS DO ACCESS OPEN– YRADIONICS TZ AREA WATCH ENDED– YRADIONICS TW AREA WATCH START– YRADIONICS YB BUSY SECONDS– , this is a receiver message YRADIONICS YK COMMUNICATION RESTORE– YRADIONICS JD DATE CHANGED– YRADIONICS RT DATE LOST– YRADIONICS DU DEALER ID– YRADIONICS DF DOOR FORCED YRADIONICS DR DOOR RESTORAL YRADIONICS DS DOOR STATION– YRADIONICS NF FORCED PERIMETER ARM – YRADIONICS XW FORCED POINT – YRADIONICS ZH FREEZE ALARM RESTORE – YRADIONICS ZB FREEZE BYPASS – YRADIONICS ZR FREEZE RESTORE – YRADIONICS JH HOLIDAY CHANGED – YRADIONICS LF LISTEN-IN BEGIN – YRADIONICS LE LISTEN-IN ENDED – YRADIONICS LB LOCAL PROGRAM BEGIN – YRADIONICS LD LOCAL PROGRAM DENIED – YRADIONICS LS LOCAL PROGRAM SUCCESS – YRADIONICS JO LOG OVERFLOW – YRADIONICS JL LOG THRESHOLD – YRADIONICS YG PARAMETER CHANGED – YRADIONICS NL PERIMETER ARMED – YRADIONICS LR PHONE LINE RESTORE – YRADIONICS RR POWER UP – YRADIONICS VZ PRINTER OFFLINE – YRADIONICS VY PRINTER ON LINE – YRADIONICS VI PRINTER PAPER IN – YRADIONICS VO PRINTER PAPER OUT – YRADIONICS VR PRINTER RESTORE – YRADIONICS VX PRINTER TEST – YRADIONICS ND14 RE-BOOT – YRADIONICS RC RELAY CLOSE – YRADIONICS RO RELAY OPEN – YRADIONICS RB REMOTE PROGRAM BEGIN – YRADIONICS RD REMOTE PROGRAM DENIED – YRADIONICS RS REMOTE PROGRAM SUCCESS – YRADIONICS RN REMOTE RESET – YRADIONICS JS SCHEDULE CHANGED – YRADIONICS JR SCHEDULE EXECUTED – YRADIONICS XI SENSOR RESET – YRADIONICS YX SERVICE REQUIRED – YRADIONICS YY STATUS REPORT – YRADIONICS TB TAMPER BYPASS – YRADIONICS TR TAMPER RESTORE – YRADIONICS TU TAMPER UNBYPASS – YRADIONICS JT TIME CHANGED – YRADIONICS XR TRANSMITTER BATTERY RESTORE – YRADIONICS UH UNTYPED ALARM RESTORE YRADIONICS UZ UNTYPED MISSING ALARM YRADIONICS UJ UNTYPED TROUBLE RESTORE YRADIONICS UA UNTYPED ZONE ALARM YRADIONICS UB UNTYPED ZONE BYPASS YRADIONICS UR UNTYPED ZONE RESTORE YRADIONICS US UNTYPED ZONE SUPERVISORY YRADIONICS UU UNTYPED ZONE UNBYPASS YRADIONICS JV USER CODE CHANGED – YRADIONICS JX USER CODE DELETED – YRADIONICS JA USER CODE TAMPER – YRADIONICS ND09 WATCH DOG RESET – YRADIONICS YW WATCHDOG RESET – YRADIONICS WH WATER ALARM RESTORE – YRADIONICS WB WATER BYPASS – Y
CSAA Scope for Handling, edited Page 14 of 30 4/7/2023
RADIONICS WR WATER RESTORE – YRADIONICS WJ WATER TROUBLE RESTORE – YRADIONICS WU WATER UNBYPASS – YSIA AB ABORT – YSIA AR AC RESTORE – YSIA AT AC TROUBLE – YSIA DC ACCESS CLOSED – YSIA DD ACCESS DENIED – YSIA DZ ACCESS DENIED-DOOR SECURED – YSIA DW ACCESS DENIED-INTERLOCK – YSIA DI ACCESS DENIED-PASSBACK – YSIA DQ ACCESS DENIED-UNAUTH ARMING STATE – YSIA DP ACCESS DENIED-UNAUTH. TIME – Y
SIA DVACCESS DENIED-UNAUTHORIZED-ENTRY –LEVEL
Y
SIA DG ACCESS GRANTED – YSIA DK ACCESS LOCK OUT – YSIA DO ACCESS OPEN – YSIA NS ACTIVITY RESUMED – YSIA AN ANALOG RESTORAL – YSIA AS ANALOG SERVICE – YSIA TZ AREA WATCH END – YSIA TW AREA WATCH START – YSIA YH BELL RESTORED – YSIA YB BUSY SECONDS – YSIA OC CANCEL REPORT – YSIA DA CARD ASSIGNED – YSIA DB CARD DELETED – YSIA YK COMMUNICATION RESTORAL – YSIA CX CUSTOM FUNCTION EXECUTED – YSIA JD DATE CHANGED – YSIA DU DEALER ID – YSIA OR DISARM FROM ALARM – YSIA DF DOOR FORCED – YSIA DN DOOR LEFT OPEN – YSIA DL DOOR LEFT OPEN-ALARM – YSIA DH DOOR LEFT OPEN-RESTORE – YSIA DY DOOR LOCKED – YSIA DR DOOR RESTORAL – YSIA DS DOOR STATION – YSIA QH EMERGENCY ALARM RESTORE – YSIA QB EMERGENCY BYPASS – YSIA QR EMERGENCY RESTORE – YSIA QU EMERGENCY UNBYPASS – YSIA IA EQUIPMENT FUNCTION CONDITION – YSIA ER EXPANSION RESTORE – YSIA EJ EXPANSION TAMPER RESTORE – YSIA EX EXTERNAL DEVICE CONDITION – YSIA XE EXTRA POINT – YSIA XF EXTRA RF POINT – YSIA NF FORCED PERIMETER ARMED – YSIA XW FORCED POINT – YSIA ZH FREEZE ALARM RESTORE – YSIA ZB FREEZE BYPASS – YSIA ZR FREEZE RESTORE – YSIA LF LISTEN-IN BEGIN – YSIA LE LISTEN-IN ENDED – YSIA LB LOCAL PROGRAM BEGIN – YSIA LD LOCAL PROGRAM DENIED – YSIA LU LOCAL PROGRAM FAIL – YSIA LS LOCAL PROGRAM SUCCESS – YSIA LX LOCAL PROGRAMMING ENDED – YSIA JO LOG OVERFLOW – YSIA JL LOG THRESHOLD – YSIA XL LOW RECEIVED SIGNAL STRENGTH – YSIA CM MISSING ALARM-RECENT CLOSING – YSIA OG OPEN AREA – Y
CSAA Scope for Handling, edited Page 15 of 30 4/7/2023
SIA OS OPENING KEYSWITCH – YSIA OP OPENING REPORT – YSIA OV OUTPUT STATE-RESTORE – YSIA YF PARAMETER CHECKSUM FAIL – YSIA NL PERIMETER ARMED – YSIA NM PERIMETER ARMED-USER DEFINED – YSIA LR PHONE LINE RESTORAL – YSIA RR POWER UP – YSIA VZ PRINTER OFFLINE – YSIA VY PRINTER ONLINE – YSIA VI PRINTER PAPER IN – YSIA VO PRINTER PAPER OUT – YSIA VR PRINTER RESTORE – YSIA VX PRINTER TEST – YSIA RB REMOTE PROGRAM BEGIN – YSIA RD REMOTE PROGRAM DENIED – YSIA RS REMOTE PROGRAM SUCCESS – YSIA RN REMOTE RESET – YSIA DE REQUEST TO ENTER – YSIA DX REQUEST TO EXIT – YSIA XQ RF INTERFERENCE – YSIA XH RF INTERFERENCE RESTORE – YSIA XJ RF RECEIVER TAMPER RESTORAL – YSIA JS SCHEDULE CHANGED – YSIA JR SCHEDULE EXECUTED – YSIA XI SENSOR RESET – YSIA YZ SERVICE COMPLETED – YSIA YX SERVICE REQUIRED – service only YSIA SH SPRINKLER ALARM RESTORE – YSIA SB SPRINKLER BYPASS – YSIA SR SPRINKLER RESTORE – YSIA SU SPRINKLER UNBYPASS – YSIA YY STATUS REPORT – YSIA YR SYSTEM BATTERY RESTORAL – YSIA TH TAMPER ALARM RESTORE – YSIA TB TAMPER BYPASS – YSIA TR TAMPER RESTORAL – YSIA TU TAMPER UNBYPASS – YSIA JT TIME CHANGED – YSIA XR TRANSMITTER BATTERY RESTORE – YSIA JY USER CODE ADDED – YSIA JV USER CODE CHANGED – YSIA JX USER CODE DELETED – YSIA JZ USER LEVEL SET – YSIA JP USER ON PREMISES – YSIA CW WAS FORCED ARMED – YSIA YW WATCHDOG RESET – YSIA WH WATER ALARM RESTORE – YSIA WB WATER BYPASS – YSIA WR WATER RESTORAL – YSIA WU WATER UNBYPASS – Y
2.10. Other Supervisory – Non Critical Codes 2.10.1. Handling Instruction. Premises and alarm company2.10.2. These codes are non-emergency; however, the premises and
alarm company shall be informed of the transmission2.10.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 428 ACCESS POINT RTE TROUBLE Y YCID 464 AUTO ARM TIME EXTENDED Y YCID 311 BATTERY MISSING Y YCID 309 BATTERY TEST FAIL Y YCID 521 BELL 1 DISABLE Y YCID 522 BELL 2 DISABLE Y Y
CSAA Scope for Handling, edited Page 16 of 30 4/7/2023
CID 411 CALLBACK REQUESTED Y YCID 551 DIALER DISABLED Y YCID 415 DIALER SHUTDOWN Y YCID 423 FORCED ACCESS Y YCID 387 INTRUSION HI SENS. Y YCID 388 INTRUSION LO SENS. Y YCID 356 LOSS CENTRAL POLLING Y YCID 357 LRR XMTR.VSWR Y YCID 601 MANUALLY TRIGGERED TEST Y YCID 531 MODULE ADDED Y YCID 532 MODULE REMOVED Y YCID 327 NOTIFICATION APPLIANCE CKT #4 Y YCID 326 NOTIFICATION APPLIANCE CKT.# Y YCID 603 PERIODIC RF XMIT Y YCID 331 POLLING LOOP OPEN Y YCID 332 POLLING LOOP SHORT Y YCID 370 PROTECTION LOOP Y YCID 371 PROTECTION LOOP OPEN Y YCID 372 PROTECTION LOOP SHORT Y YCID 552 RADIO XMTR DISABLED Y YDMP L LATE TO ARM Y YDMP S91 SERVICE REQUESTED Y YDMP ASV SUPERVISORY Y YITI I IMPROPER SECURITY CODE Y YITI SX S100 SUPERVISORY UNIT Y YITI SX S102 SUPERVISORY UNIT Y YMODEM III A4 EXTERNAL DEVICE Y YMODEM III 81 EXTRA ACCOUNT Y YMODEM III 17 EXTRA POINT Y YMODEM III 65 EXTRA RF POINT Y YMODEM III AA PRINTER PAPER OUT Y YRADIONICS XE EXTRA POINT - Y YRADIONICS XF EXTRA RF POINT- Y YSIA SC CHANGE OF STATE - Y YSIA XA EXTRA ACCOUNT REPORT – Y YSIA YN INVALID REPORT - Y YSIA MI MESSAGE – Y YSIA BZ MISSING SUPERVISION - Y YSIA NC NETWORK CONDITION – Y YSIA YM SYSTEM BATTERY MISSING Y YSIA YO UNKNOWN MESSAGE – Y YSIA UH UNTYPED ALARM RESTORE– Y YSIA UZ UNTYPED MISSING ALARM– Y YSIA UB UNTYPED ZONE BYPASS– Y YSIA UR UNTYPED ZONE RESTORE– Y YSIA US UNTYPED ZONE SUPERVISORY– Y YSIA UG UNVERIFIED EVENT-UNTYPED– Y Y
2.11. Other Supervisory – Non Critical Codes 2.11.1. Handling Instruction. Premises, responding party and alarm company2.11.2. These codes are non-emergency; however, the premises,
responding parties and alarm company shall be informed of the transmission
2.11.3. Code Table:FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTH
NOTIFY PREM
RPALARM CO.
CID 102 FAIL TO REPORT IN Y Y YCID 642 LATCH-KEY SUPERVISION Y Y YCID 331 POLLING LOOP OPEN Y Y YCID 332 POLLING LOOP SHORT Y Y YCID 384 RF XMTR LOW BATTERY Y Y YCID 156 DAY TROUBLE Y Y YCID 200 FIRE SUPERVISORY Y Y YCID 158 HIGH TEMPERATURE Y Y YCID 161 LOSS OF AIR FLOW Y Y Y
CSAA Scope for Handling, edited Page 17 of 30 4/7/2023
CID 153 LOSS OF HEAT Y Y YCID 157 LOW BOTTLE GAS LEVEL Y Y YCID 202 LOW CO2 Y Y YCID 159 LOW TEMPERATURE Y Y YCID 204 LOW WATER LEVEL Y Y YCID 201 LOW WATER PRESSURE Y Y YCID 205 PUMP ACTIVATED Y Y YCID 206 PUMP FAILURE Y Y YCID 152 REFRIGERATION Y Y YCID 163 TANK LEVEL TROUBLE Y Y YCID 154 WATER LEAKAGE Y Y YDMP S93 ALARM: USER ACTIVITY NOT DECTECTED Y Y YDMP TSV TROUBLE SUPERVISORY Y Y YDMP T3 TROUBLE/SUPERVISORY Y Y YDMP HA1 WIRELESS ZONE MISSING AUXILIARY 1 Y Y YDMP HA2 WIRELESS ZONE MISSING AUXILIARY 2 Y Y YDMP HBL WIRELESS ZONE MISSING BLANK Y Y YDMP HSV WIRELESS ZONE MISSING SUPERVISORY Y Y YDMP D0 XMTR LOW BATTERY BLANK Y Y YDMP D3 XMTR LOW BATTERY SUPERVISORY Y Y YDMP H6 XMTR MISSING AUXILIARY 1 Y Y YDMP H7 XMTR MISSING AUXILIARY 2 Y Y YDMP H0 XMTR MISSING BLANK Y Y YDMP H3 XMTR MISSING SUPERVISORY Y Y YITI S SUPERVISORY Y Y YITI S89 SUPERVISORY / LOW BATTERY UNIT Y Y YITI SX S SUPERVISORY Y Y YMODEM III 4A BATTERY MISSING Y Y YMODEM III 82 LOW SIGNAL LEVEL Y Y YMODEM III A6 LOW TEMPERATURE Y Y YMODEM III 93 MISSING SUPERVISION Y Y YMODEM III 5D RF BATTERY LOW Y Y YMODEM III 89 RF TAMPER ALARM Y Y YMODEM III 4E TEMP ALARM Y Y YRADIONICS ZS FREEZE SUPERVISORY Y Y YRADIONICS YM SYSTEM BATTERY MISSING Y Y YRADIONICS XT TRANSMITTER BATTERY TROUBLE Y Y YRADIONICS WS WATER SUPERVISORY Y Y YRADIONICS ZA FREEZE ALARM Y Y YRADIONICS WA WATER ALARM Y Y YSIA YA BELL FAULT Y Y YSIA QS EMERGENCY SUPERVISORY Y Y YSIA JK LATCHKEY ALERT Y Y YSIA NA NO ACTIVITY Y Y YSIA XS RF RECEIVER TAMPER Y Y YSIA SS SPRINKLER SUPERVISORY Y Y YSIA WS WATER SUPERVISORY Y Y YSIA ZA FREEZE ALARM Y Y YSIA ZS FREEZE SUPERVISORY Y Y YSIA WA WATER ALARM Y Y Y
3. Non Critical Codes, Trouble3.1. Burglary – Trouble– Non Critical Codes
3.1.1. Handling Instruction. Alarm company3.1.2. These codes are non-emergency; however, the alarm company shall be informed
of the transmission3.1.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
DMP X2 BYPASS BURLARY Y
DMP F2 FAIL BURLARY Y
DMP W2 FAULT BURGLARY Y
DMP WBU FAULT BURGLARY Y
RADIONICS BR BURGLARY RESTORE Y
CSAA Scope for Handling, edited Page 18 of 30 4/7/2023
RADIONICS BJ BURGLARY TROUBLE RESTORE Y
SIA BJ BURGLARY TROUBLE RESTORE Y
3.2. Burglary – Trouble– Non Critical Codes3.2.1. Handling Instruction. The supervising station shall notify premises, responding
parties and alarm company3.2.2. These codes are non-emergency; however, the premises, responding
parties and alarm company shall be informed of the transmission3.2.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
DMP DBU LOW BATTERY BURGLARY Y Y YDMP TBU TROUBLE BURGLARY Y Y YDMP T2 TROUBLE/BURG Y Y YDMP D2 XMTR LOW BATTERY BURGLARY Y Y YRADIONICS BT BURGLARY TROUBLE Y Y YSIA BT BURGLARY TROUBLE Y Y Y
3.3. Fire – Trouble – Non Critical Codes3.3.1. Handling Instruction. Alarm company3.3.2. These codes are non-emergency; however, the premises and alarm company
shall be informed of the transmission3.3.3. Code Table:
FORMAT EVENT CODEZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 384 RF XMTR LOW BATTERY Y Y
DMP D1 XMTR LOW BATTERY FIRE Y Y
DMP DFI LOW BATTERY FIRE Y Y
DMP F1 FAIL FIRE Y Y
DMP H1 XMTR MISSING FIRE Y Y
DMP HFI WIRELESS ZONE MISSING FIRE Y Y
DMP W1 FAULT FIRE Y Y
DMP WFI FAULT FIRE Y Y
MODEM II 7E FIRE SPRVN TROUBLE RST Y Y
MODEM II 86 S: FIRE TROUBLE Y Y
RADIONICS FJ FIRE TROUBLE RESTORE Y Y
RADIONICS GJ GAS TROUBLE RESTORE Y Y
RADIONICS GR GAS RESTORAL Y Y
RADIONICS GT GAS TROUBLE Y Y
RADIONICS KJ HEAT TROUBLE RESTORE Y Y
RADIONICS SJ SPRINKLER TROUBLE RESTORE Y Y
RADIONICS SR SPRINKLER RESTORE Y Y
SIA FQ FIRE SUPERVISORY TROUBLE RESTORE Y
SIA FX FIRE TEST Y
SIA FI FIRE TEST BEGIN Y
SIA FK FIRE TEST END Y
SIA FJ FIRE TROUBLE RESTORE Y
SIA GT GAS TROUBLE Y
SIA GJ GAS TROUBLE RESTORE Y
SIA KJ HEAT TROUBLE RESTORE Y
3.4. Medical – Trouble – Non Critical Codes3.4.1. Handling Instruction. Alarm company3.4.2. These codes are non-emergency; however, the alarm company shall be informed
of the transmission
CSAA Scope for Handling, edited Page 19 of 30 4/7/2023
3.4.3. Code Table:FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTH
NOTIFY PREM
RPALARM CO.
SIA HJ HOLDUP TROUBLE RESTORE Y
SIA MJ MEDICAL TROUBLE RESTORE Y
3.5. Medical – Trouble – Non Critical Codes3.5.1. Handling Instruction. Premises, responding parties, and alarm company3.5.2. These codes are non-emergency; however, the premises, responding
parties, and alarm company shall be informed of the transmission3.5.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
SIA HT HOLDUP TROUBLE Y Y Y
RADIONICS MT MEDICAL TROUBLE Y Y Y
SIA MT MEDICAL TROUBLE Y Y Y
3.6. Panic – Trouble – Non Critical Codes3.6.1. Handling Instruction. Premises, responding parties and alarm company3.6.2. These codes are non-emergency; however, the premises, responding parties and
alarm company shall be informed of the transmission3.6.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 375 PANIC ZONE TROUBLE Y Y Y
DMP DEM LOW BATTERY EMERGENCY Y Y Y
DMP DPN LOW BATTERY PANIC Y Y Y
DMP T4 TROUBLE/PANIC Y Y Y
DMP T5 TROUBLE/EMERGENCY Y Y Y
DMP TEM TROUBLE EMERGENCY Y Y Y
DMP D5 XMTR LOW BATTERY EMERGENCY Y Y Y
Radionics PT PANIC TROUBLE Y Y Y
Radionics QT EMERGENCY TROUBLE Y Y Y
SIA HT HOLDUP TROUBLE Y Y Y
SIA PT PANIC TROUBLE Y Y Y
3.7. Panic – Trouble – Non Critical Codes3.7.1. Handling Instruction. Alarm company3.7.2. These codes are non-emergency; however, the alarm company shall
be informed of the transmission3.7.3. Code Table:
FORMATEVENT
CODEZONE
DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
DMP F4 FAIL PANIC Y
DMP F5 FAIL EMERGENCY Y
DMP TPN TROUBLE PANIC Y
DMP W4 FAULT PANIC Y
DMP W5 FAULT EMERGENCY Y
DMP WEM FAULT EMERGENCY Y
DMP WPN FAULT PANIC Y
Radionics PJ PANIC TROUBLE RESTORE Y
Radionics QJ EMERGENCY TROUBLE RESTORE Y
SIA HJ HOLDUP TROUBLE RESTORE Y
CSAA Scope for Handling, edited Page 20 of 30 4/7/2023
SIA PJ PANIC TROUBLE RESTORE Y
3.8. Other Trouble – Non Critical Codes3.8.1. Handling Instruction. Responding party, alarm company, premises3.8.2. These codes are non-emergency; however, the responding party, alarm company
and premise shall be informed of the transmission3.8.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
ADEMCO SUPERFAST 62 LOW BATTERY Y Y Y
ADEMCO SUPERFAST 8 LOW BATTERY Y Y Y
ADEMCO SUPERFAST 63 SYSTEM FAILURE – Y Y Y
ADEMCO SUPERFAST 66 TELCO LINE FAULT Y Y Y
ADEMCO SUPERFAST 67 UNUSED ZONE TROUBLE Y Y Y
ADEMCO SUPERFAST 5 ZONE TROUBLE Y Y Y
AES Y-801 LOW BATTERY Y Y YCID 463 RE-ARM AFTER ALARM Y Y YCID 378 CROSS-ZONE TROUBLE Y Y YCID 338 EXP MOD LOW BATTERY Y Y YCID 341 EXP MOD TAMPER Y Y YCID 333 EXP.MODULE FAILURE Y Y YCID 343 EXP.MODULE SELF TEST FAIL Y Y YCID 102 FAIL TO REPORT IN Y Y YCID 376 HOLD UP ZONE TROUBLE Y Y Y
CID 353LONG RANGE RADIO XMITTER FAULT – shall this me moved to critical troubles?
Y Y Y
CID 356 LOSS CENTRAL POLLING Y Y YCID 355 LOSS OF RADIO SUPERVISION Y Y YCID 302 LOW SYSTEM BATTERY Y Y YCID 384 RF XMTR LOW BATTERY Y Y YCID 383 SENSOR TAMPER TROUBLE Y Y YCID 380 SENSOR TROUBLE-GLOBAL Y Y YCID 391 SENSOR WATCH FAILURE Y Y Y
CID 641SENSOR WATCH TROUBLE This shall be Senior watch trouble not sensor.
Y Y Y
CID 320 SOUNDER/RELAY TROUBLE Y Y YCID 330 SYSTEM PERIPHERAL TROUBLE Y Y YCID 300 SYSTEM TROUBLE Y Y YCID 608 SYSTEM TROUBLE PRESENT Y Y YCID 351 TELCO FAULT 1 Y Y YCID 352 TELCO FAULT 2 Y Y YCID 321 TROUBLE/BELL 1 Y Y YCID 322 TROUBLE/BELL 2 Y Y YCID 382 TROUBLE/LOSS OF SUPER RPM Y Y YCID 381 TROUBLE/LOSS OF SUPERVISION RF Y Y YCID 156 DAY TROUBLE Y Y YCID 155 FOIL BREAK TROUBLE – this is also in critical Y Y YDMP D6 XMTR LOW BATTERY AUXILIARY 1 Y Y YDMP D7 XMTR LOW BATTERY AUXILIARY 2 Y Y YDMP DA1 LOW BATTERY AUXILIARY 1 Y Y YDMP DA2 LOW BATTERY AUXILIARY 2 Y Y YDMP DBL LOW BATTERY BLANK Y Y YDMP S09 WARNING: LOW STANDBY BATTERY Y Y YDMP S10 WARNING: LOW COMMUNICATION LINE LEVEL Y Y YDMP S11 WARNING: PANEL TAMPER Y Y YDMP S12 WARNING: PANEL BACKUP COMMUNICATION Y Y YDMP S13 WARNING: PANEL GROUND FAULT Y Y YDMP S14 WARNING NON-ALARM MESSAGE OVERFLOW Y Y YDMP S16 WARNING: PANEL NOT RESPONDING Y Y YDMP S18 ALARM: ZONE ALARM OVERFLOW Y Y YDMP S19 WARNING: NEW PANEL ON LINE Y Y Y
CSAA Scope for Handling, edited Page 21 of 30 4/7/2023
DMP S21 TROUBLE: MESSAGE NOT ACKNOWLEDGED Y Y YDMP S26 WARNING: AUXILIARY FUSE TROUBLE Y Y YDMP S28 WARNING: TELEPHONE LINE 1 TROUBLE Y Y YDMP S30 WARNING: TELEPHONE LINE 2 TROUBLE Y Y YDMP S32 WARNING: TROUBLE ALERT SILENCED Y Y YDMP S33 TROUBLE ALERT RETURNED TO NORMAL Y Y YDMP S34 WARNING: ALARM BELL SILENCED Y Y YDMP S38 WARNING: BELL CIRCUIT TROUBLE Y Y YDMP S43 WARNING: BELL FUSE TROUBLE Y Y Y
DMP S48WARNING: LOW BATTERY CUTOFF-LAST MESSAGE
Y Y Y
DMP S49 WARNING: SYSTEM SUPERVISORY TROUBLE Y Y YDMP S50 WARNING: SUPERVISED WIRELESS TROUBLE Y Y YDMP S51 WARNING: ZONE INTERROGATION TROUBLE Y Y Y
DMP S54WARNING: UNSUCCESSFUL REMOTE CONNECT
Y Y Y
DMP S59 WARNING: SUBSTITUTE/CHECK IN OVERFLOW Y Y YDMP S60 WARNING: REDUNDANT RECEIVER FAILURE Y Y YDMP S61 WARNING: COMMUNICATION TROUBLE-LINE 1 Y Y YDMP S62 WARNING: COMM.TROUBLE LINE 2 Y Y YDMP S63 WARNING: COMMUNICATION TROUBLE-LINE 3 Y Y YDMP S64 WARNING: COMM TROUBLE LINE 4 Y Y YDMP S65 WARNING: COMMUNICATION TROUBLE-LINE 5 Y Y YDMP S68 RECEIVER PRINTER FAILED Y Y YDMP S69 RECEIVER PRINTER RESTORE Y Y YDMP S72 WARNING: NETWORK TROUBLE Y Y YDMP S73 NETWORK RESTORED Y Y Y
DMP S75SIMMS OPERATOR ACKNOWLEDGMENT-FAILURE
Y Y Y
DMP S76SIMMS OPERATOR ACKONWLEDGMENT RESTORE
Y Y Y
DMP S80 ALERT: EXIT ERROR Y Y YDMP S86 WARNING: LOCAL PROGRAMMING Y Y YDMP S87 WARNING: TRANSMIT FAIL Y Y Y
DMP S88AUTOMATIC RECALL OK-UNRESTORED SYSTEM
Y Y Y
DMP S90 WARNING: UNRECOGNIZED MESSAGE Y Y YDMP S92 WARNING: NO ARM/DISARM ACTIVITY Y Y YDMP T0 TROUBLE Y Y YDMP T6 TROUBLE/AUXILIARY 1 Y Y YDMP T7 TROUBLE/AUXILIARY 2 Y Y YDMP TA1 TROUBLE AUXILIARY 1 Y Y YDMP TA2 TROUBLE AUXILIARY 2 Y Y YDMP TBL TROUBLE BLANK Y Y YITI A88 ALARM TROUBLE (ENERGY SAVER) Y Y YITI A78 ALARM TROUBLE/FREEZE Y Y YITI E EXIT FAULT Y Y YITI L LOW BATTERY Y Y YITI L89 LOW BATTERY UNIT Y Y YITI L91 LOW CPU BATTERY Y Y YITI A94 RECEIVER FAILURE Y Y YITI A89 TROUBLE Y Y YITI J TROUBLE Y Y YITI W78 TROUBLE FREEZE SENSOR Y Y YMODEM 4112 & 6113 6 TROUBLE Y Y Y
MODEM 8113
6 TROUBLE Y Y Y
MODEM 8114
C TROUBLE Y Y Y
MODEM III 4B BATTERY LOW Y Y YMODEM III 14 MISSING TROUBLE Y Y YMODEM III 44 PHONE LINE FAIL Y Y YMODEM III 18 POINT BUSS TROUBLE Y Y YMODEM III 60 RF RCVR TROUBLE Y Y YMODEM III 6B RF TAMPER TROUBLE Y Y YMODEM III 46 SDI FAILURE Y Y YMODEM III 8B SENSOR TROUBLE Y Y Y
CSAA Scope for Handling, edited Page 22 of 30 4/7/2023
MODEM III 42 TROUBLE Y Y YMODEM III 11 TROUBLE REPORT Y Y YRADIONICS VT PRINTER TROUBLE – Y Y YRADIONICS AT AC TROUBLE – Y Y YRADIONICS LT PHONE LINE TROUBLE Y Y YRADIONICS UT UNTYPED ZONE TROUBLE Y Y YRADIONICS UY UNTYPED MISSING TROUBLE Y Y YRADIONICS V MISSING TROUBLE Y Y YRADIONICS WT WATER TROUBLE – Y Y YRADIONICS YO UNKNOWN MESSAGE – Y Y YRADIONICS YP POWER SUPPLY TROUBLE Y Y YRADIONICS YS COMMUNICATION TROUBLE Y Y YRADIONICS YT SYSTEM BATTERY TROUBLE Y Y YRADIONICS ZT FREEZE TROUBLE Y Y YSIA DT ACCESS TROUBLE Y Y YSIA YS COMMUNICATION TROUBLE Y Y YSIA YU DIAGNOSTIC ERROR – Y Y YSIA QJ EMERGENCY TROUBLE Y Y YSIA QT EMERGENCY TROUBLE Y Y YSIA EE EXIT ERROR Y Y YSIA EM EXPANSION DEVICE MISSING Y Y YSIA ET EXPANSION TROUBLE Y Y YSIA EZ MISSING ALARM-EXIT ERROR – Y Y YSIA NT NETWORK FAILURE – Y Y YSIA OU OUTPUT STATE-TROUBLE – Y Y YSIA YI OVERCURRENT TROUBLE Y Y YSIA LT PHONE LINE TROUBLE Y Y YSIA YP POWER SUPPLY TROUBLE Y Y YSIA VT PRINTER TROUBLE – , customer specific Y Y YSIA ST SPRINKLER TROUBLE – move to critical Y Y YSIA BD SWINGER TROUBLE Y Y YSIA YT SYSTEM BATTERY TROUBLE Y Y YSIA TT TAMPER TROUBLE Y Y YSIA XT TRANSMITTER BATTERY TROUBLE Y Y YSIA UY UNTYPED MISSING TROUBLE - Y Y YSIA UJ UNTYPED TROUBLE RESTORE – Y Y YSIA UT UNTYPED ZONE TROUBLE – Y Y YSIA UU UNTYPED ZONE UNBYPASS – Y Y YSIA WT WATER TROUBLE – Y Y YSIA WJ WATER TROUBLE RESTORE – Y Y YSIA ZT FREEZE TROUBLE – this is also in critical Y Y Y
3.9. Other Trouble – Non Critical Codes3.9.1. Handling Instruction. Alarm company 3.9.2. These codes are non-emergency; however, the alarm company
shall be informed of the transmission3.9.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
ADEMCO SUPERFAST 61 AC LOSS Y
ADEMCO SUPERFAST 65 FAIL TO COMMUNICATE Y
ADEMCO SUPERFAST 64 WATCHDOG TIMER RESET Y
AES T-904 AC LOSS YAES Y-809 AC LOSS YAES AES COMM FAIL YAES T-903 COMMUNICATION TIME-OUT CONDITION Y
AES ST-903
COMMUNICATION TIME-OUT REPORTED DURING CHECK-IN
Y
AES Y-800 DIAGNOSTIC - NO FAULTS - UNIT OK YAES Y-805 MODEM CHIP FAILED (U9) YAES Y-808 MODEM LOOPBACK FAILED (U9) YAES Y-807 RAM CHIP FAILURE (U11) YAES Y-803 RAM CHIP INTERNAL BATTERY BAD (U11) YAES Y-802 RAM DATA ERROR - REPROGRAM UNIT YAES Y-806 TIMING ERROR Y
CSAA Scope for Handling, edited Page 23 of 30 4/7/2023
CID 301 AC LOSS YCID 350 COMMUNICATIONS FAILURE YCID 337 EXP MOD DC LOSS YCID 339 EXP MOD RESET YCID 342 EXP MODULE AC LOSS YCID 354 FAILURE TO COMMUNICATE YCID 336 LOCAL PRINTER FAILURE YCID 335 LOCAL PRINTER PAPER OUT YCID 312 POWER SUPPLY OVERCURRENT YCID 552 RADIO XMTR DISABLED YCID 303 RAM CHECKSUM BAD YCID 459 RECENT CLOSE/TROUBLE YCID 334 REPEATER FAILURE YCID 525 REVERSING RELAY DISABLE YCID 325 REVERSING RELAY TROUBLE YCID 344 RF RCVR JAM DETECT # YCID 304 ROM CHECKSUM BAD YCID 307 SELF-TEST FAILURE YCID 520 SOUNDER/RELAY DIS. YCID 305 SYSTEM RESET YCID 308 SYSTEM SHUTDOWN YCID 414 SYSTEM SHUTDOWN YCID 626 TIME/DATE INACCURATE YCID 625 TIME/DATE RESET YCID 324 TROUBLE RELAY YCID 524 TROUBLE RELAY DISABLE YCID 323 TROUBLE/ALARM RELAY YDMP S08 WARNING: AC POWER FAILURE YITI A90 AC POWER FAILURE YITI W90 AC POWER RESTORED YMODEM III 48 AC FAILURE YMODEM III 02 BAD CALL TO RAM YMODEM III 50 CHECKSUM FAIL YMODEM III 79 EQUIP FAIL YMODEM III 6D EQUIP RESTORAL YMODEM III 97 FAIL TO EXECUTE YMODEM III 51 MEMORY FAIL YMODEM III 76 NETWORK FAIL YMODEM III AD OUTPUT TROU YMODEM III AE OUTPUT TROUBLE RESTORE YMODEM III 53 PARAMS BAD YMODEM III 3F PROG ACCESS BAD YMODEM III 41 RAM ACCESS FAIL YMODEM III 8F S: MISSING TROUBLE YMODEM III 8A S: RF TAMPER TRB YMODEM III 0A S: TROUBLE YRADIONICS DM TROUBLE DOOR LEFT OPEN YRADIONICS DT ACCESS TROUBLE – service only YRADIONICS LU LOCAL PROGRAM FAIL YRADIONICS LX LOCAL PROGRAMMING ENDED YRADIONICS P AC FAIL YRADIONICS RA REMOTE PROGRAM CALL FAIL YRADIONICS RU REMOTE PROGRAM FAIL YRADIONICS YC COMMUNICATIONS FAIL YRADIONICS YD RECEIVER LINECARD TROUBLE YRADIONICS YE RECEIVER LINECARD RESTORE YRADIONICS YF PARAMETER CHECKSUM FAIL YRADIONICS YN INVALID REPORT YRADIONICS YQ POWER SUPPLY RESTORED YRADIONICS YR SYSTEM BATTERY RESTORE YRADIONICS ZJ FREEZE TROUBLE RESTORE YSIA YC COMMUNICATIONS FAIL YSIA RT DATA LOST YSIA DJ DOOR FORCED-TROUBL YSIA DM DOOR LEFT OPEN-TROUBLE YSIA IR EQUIPMENT FAIL-RESTORE YSIA EN EXPANSION MISSING RESTORE Y
CSAA Scope for Handling, edited Page 24 of 30 4/7/2023
SIA ZJ FREEZE TROUBLE RESTORE YSIA NR NETWORK RESTORAL YSIA YJ OVERCURRENT RESTORE YSIA YG PARAMETER CHANGED YSIA YQ POWER SUPPLY RESTORED YSIA YE RECEIVER LINECARD RESTORED YSIA YD RECEIVER LINECARD TROUBLE YSIA RU REMOTE PROGRAM FAIL YSIA RA REMOTE PROGRAMMER CALL FAILED YSIA SJ SPRINKLER TROUBLE RESTORE YSIA BE SWINGER TROUBLE RESTORE YSIA TJ TAMPER TROUBLE RESTORE Y
4. Test - Non Critical Codes 4.1. Burglary- Test – Non Critical Codes
4.1.1. Handling Instruction. No response4.1.2. These codes are for testing purposes and do not require attention4.1.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 611 POINT TESTED OK
DMP FBU WALK TEST FAIL BURGLARY
DMP KBU WALK TEST ZONE VERIFY BURGLARY
RADIONICS BX BURGLARY TEST
SIA BX BURGLARY TEST
4.2. Fire - Test - Non Critical Codes4.2.1. Handling Instruction. Alarm company4.2.2. These codes are for testing purposes and the alarm company shall be notified4.2.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
DMP FFI WALK TEST FAIL FIRE Y
DMP KFI WALK TEST ZONE VERIFY FIRE Y
RADIONICS FX FIRE TEST Y
RADIONICS FI FIRE TEST BEGIN Y
RADIONICS FK FIRE TEST END Y
RADIONICS GX GAS TEST Y
SIA GX GAS TEST Y
4.3. Panic- Test - Non Critical Codes4.3.1. Handling Instruction. No response4.3.2. These codes are for testing purposes and do not require attention4.3.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 615 PANIC ZONE WALK TESTED
DMP FEM WALK TEST FAIL EMERGENCY
DMP FPN WALK TEST FAIL PANIC
DMP KEM WALK TEST ZONE VERIFY EMERGENCY
DMP KPN WALK TEST ZONE VERIFY PANIC
4.4. Other Test- Non Critical Codes4.4.1. Handling Instruction. No response4.4.2. These codes are for testing purposes and do not require attention4.4.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTH NOTIFY RP ALARM
CSAA Scope for Handling, edited Page 25 of 30 4/7/2023
PREM CO.ADEMCO SUPERFAST 9 TEST
ADEMCO SUPERFAST 68 WALK TEST
DMP ETS TEST EQUIPMENT DMP KA1 WALK TEST ZONE VERIFY AUXILIARY 1 DMP KA2 WALK TEST ZONE VERIFY AUXILIARY 2 DMP KBL WALK TEST ZONE VERIFY BLANK DMP S07 AUTOMATIC RECALL TEST OK DMP S23 PANEL TEST SIGNAL RECEIVED DMP S66 SYSTEM TEST BEGIN DMP S67 SYSTEM TEST END ITI A93 AUTOMATIC PHONE TEST ITI A83 PHONE TEST ITI P PHONE TEST ITI SX A114 AUTOMATIC PHONE TEST ITI SX A106 PHONE TEST ITI SX P PHONE TEST MODEM III 19 POINTS TESTED MODEM III 33 TEST REPORT MODEM III 27 WALK TEST END MODEM III 2B WALK TEST POINT MODEM III 26 WALK TEST START RADIONCIS RP AUTOMATIC TEST RADIONCIS RX MANUAL TEST RADIONCIS TE TEST END RADIONCIS TS TEST START RADIONCIS TX TEST REPORT SIA TC ALL POINTS TESTED SIA RP AUTOMATIC TEST SIA RX MANUAL TEST SIA TE TEST END SIA TX TEST REPORT SIA TS TEST START SIA TP WALK TEST POINT
4.5. Other Test- Non Critical Codes4.5.1. Handling Instruction. Premises and alarm company4.5.2. These codes are for testing purposes and may require attention from
the premises or alarm company4.5.3. Code Table:
FORMATEVENT CODE ZONE DESCRIPTION CTV AUTH
NOTIFY PREM
RPALARM CO.
CID 601 MANUALLY TRIGGERED TEST Y YMODEM 4112 & 6112 10 TEST Y Y
MODEM 4112 & 6112 1B TEST Y Y
MODEM 8112
4-000 TEST Y Y
MODEM 8112
4-001 TEST Y Y
MODEM 8112
4-002 TEST Y Y
MODEM 8112
4-003 TEST Y Y
MODEM 8112
4-004 TEST Y Y
MODEM 8112
4-005 TEST Y Y
MODEM 8112
4-006 TEST Y Y
MODEM 8112
4-007 TEST Y Y
MODEM 8112
4-008 TEST Y Y
MODEM 8112
4-009 TEST Y Y
CSAA Scope for Handling, edited Page 26 of 30 4/7/2023
MODEM 8112
4-010 TEST Y Y
MODEM 8112
4-011 TEST Y Y
MODEM 8112
4-012 TEST Y Y
MODEM 8112
4-013 TEST Y Y
MODEM 8112
4-014 TEST Y Y
MODEM 8112
4-015 TEST Y Y
MODEM 8112
4-016 TEST Y Y
MODEM 8112
4-E TEST Y Y
MODEM 8112
4-E00 TEST Y Y
MODEM 8112
4-E01 TEST Y Y
MODEM 8112
4-E02 TEST Y Y
MODEM 8112
4-E03 TEST Y Y
MODEM 8112
4-E04 TEST Y Y
MODEM 8112
4-E05 TEST Y Y
MODEM 8112
4-E06 TEST Y Y
MODEM 8112
4-E07 TEST Y Y
MODEM 8112
4-E08 TEST Y Y
MODEM 8112
4-E09 TEST Y Y
MODEM 8112
4-E10 TEST Y Y
MODEM 8112
4-E11 TEST Y Y
MODEM 8112
4-E12 TEST Y Y
MODEM 8112
4-E13 TEST Y Y
MODEM 8112
4-E14 TEST Y Y
MODEM 8112
4-E15 TEST Y Y
MODEM 8112
4-E16 TEST Y Y
MODEM 8112
6-E TEST Y Y
MODEM 8112
6-E00 TEST Y Y
MODEM 8112
6-E01 TEST Y Y
MODEM 8112
6-E02 TEST Y Y
MODEM 8112
6-E03 TEST Y Y
MODEM 8112
6-E04 TEST Y Y
MODEM 8112
6-E05 TEST Y Y
MODEM 8112
6-E06 TEST Y Y
MODEM 8112
6-E07 TEST Y Y
MODEM 8112
6-E08 TEST Y Y
MODEM 6-E09 TEST Y Y
CSAA Scope for Handling, edited Page 27 of 30 4/7/2023
8112MODEM 8112
6-E10 TEST Y Y
MODEM 8112
6-E11 TEST Y Y
MODEM 8112
6-E12 TEST Y Y
MODEM 8112
6-E13 TEST Y Y
MODEM 8112
6-E14 TEST Y Y
MODEM 8112
6-E15 TEST Y Y
CID 389 DET.SELF TEST FAIL Y YMODEM 8112
6-E16 TEST Y Y
4.6. Other Test- Non Critical Codes4.6.1. Handling Instruction. Alarm company4.6.2. These codes are for testing purposes and may require attention from
the alarm company4.6.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
CID 602 PERIODIC TEST REPORT YCID 307 SELF-TEST FAILURE YCID 343 EXP.MODULE SELF TEST FAIL YCID 612 POINT NOT TESTED YDMP FA1 WALK TEST FAIL AUXILIARY 1 YDMP FA2 WALK TEST FAIL AUXILIARY 2 YDMP FBL WALK TEST FAIL BLANK YDMP S24 TROUBLE: SCS1 TEST SIGNAL NOT RECEIVED YMODEM III A3 TEST FAILED YSIA XX FAIL TO TEST YSIA RY TEST OFF NORMAL Y
5. Openings and Closings - Non Critical Codes5.1. Openings Closings – Non Critical
5.1.1. Handling Instruction. No response5.1.2. These codes do not require any attention5.1.3. Code Table:
FORMAT EVENT CODE ZONE DESCRIPTION CTV AUTHNOTIFY PREM
RPALARM CO.
ADEMCO SUPERFAST
4 CLOSING
ADEMCO SUPERFAST
2 OPENING
CID 441 ARMED STAY/OPENING CID 610 AUTO ARM
CIDR
403 AUTOMATIC CLOSING
CID 403 AUTOMATIC OPENING
CIDR
400 CLOSING
CIDR
401 CLOSING BY USER
CIDR
441 CLOSING/ARMED STAY
CIDR
442 CLOSING/KEYSWITCH ARMED STAY
CIDR
405 DEFERRED CLOSING
CID 405 DEFERRED OPENING
CIDR
450 EXCEPTION CLOSING
CSAA Scope for Handling, edited Page 28 of 30 4/7/2023
CID 450 EXCEPTION OPENING
CIDR
402 GROUP CLOSING
CID 402 GROUP OPENING CID 400 OPENING CID 401 OPENING BY USER
CIDR
451 EARLY CLOSING
CID 451 EARLY OPENING CID 457 EXIT ERROR/CLOSING CID 454 FAIL TO CLOSE CID 453 FAIL TO OPEN
CIDR
452 LATE CLOSING
CID 452 LATE OPENING
CIDR
404 LATE TO CLOSE
CID 404 LATE TO OPEN DMP QCL CLOSING DMP QLA LATE TO ARM DMP QOP OPENING DMP S06 SYSTEM NOT ARMED BY SCHEDULED TIME ITI C CLOSING ITI A85 CLOSING REPORT USER ITI O OPENING ITI A84 OPENING REPORT USER ITI SX C CLOSING ITI SX O OPENING ITI SX A108 CLOSING REPORT USER ITI SX A107 OPENING REPORT USER MODEM 4112 &6112 3 OPENING
MODEM 4112 &6113 2 CLOSING
MODEM 8112
2 CLOSING
MODEM 8112 3 OPENING
MODEM III 32 CLOSING REPORT MODEM III 2F OPENING REPORT MODEM III 16 POINT CLOSING MODEM III 15 POINT OPENING MODEM III 31 S: CLOSING MODEM III 2E S: OPENING MODEM III 2C EXTRA CLOSE TIME MODEM III 30 FORCED CLOSE MODEM III 63 CLOSING EARLY MODEM III 64 CLOSING LATE MODEM III 61 EARLY TO OPEN MODEM III 29 FAIL TO CLOSE MODEM III 28 FAIL TO OPEN MODEM III 68 FORCE CL EARLY MODEM III 69 FORCE CL LATE MODEM III 62 LATE TO OPEN MODEM III 4E TEMP ALARM RADIONICS CA AUTOMATIC CLOSING RADIONICS CP AUTOMATIC CLOSING RADIONICS OA AUTOMATIC OPENING RADIONICS OC CANCEL REPORT RADIONICS CG CLOSE AREA RADIONICS CE CLOSING EXTEND RADIONICS CL CLOSING REPORT RADIONICS OR DISARM FROM ALARM RADIONICS CK EARLY CLOSE RADIONICS OK EARLY OPEN RADIONICS CI FAIL TO CLOSE RADIONICS OI FAIL TO OPEN
CSAA Scope for Handling, edited Page 29 of 30 4/7/2023
RADIONICS CF FORCED CLOSING RADIONICS CJ LATE CLOSE RADIONICS OJ LATE OPEN RADIONICS CT LATE TO CLOSE RADIONICS OT LATE TO CLOSE RADIONICS OG OPEN AREA RADIONICS OP OPENING REPORT RADIONICS CZ POINT CLOSING RADIONICS OZ POINT OPENING RADIONICS CW WAS FORCED ARMED SIA CA AUTOMATIC CLOSING SIA CP AUTOMATIC CLOSING SIA OA AUTOMATIC OPENING SIA CG CLOSE AREA SIA CD CLOSING DELINQUENT SIA CS CLOSING KEYSWITCH SIA CL CLOSING REPORT SIA OK EARLY OPEN SIA OI FAIL TO OPEN SIA CF FORCED CLOSING SIA OJ LATE OPEN SIA OL LATE TO OPEN FROM ALARM SIA CZ POINT CLOSING SIA OZ POINT OPENING SIA RC RELAY CLOSE SIA RO RELAY OPEN SIA CQ REMOTE CLOSING SIA OQ REMOTE OPENING SIA CE CLOSING EXTEND SIA CK EARLY CLOSE SIA OH EARLY TO OPEN FROM ALARM SIA CJ LATE CLOSE SIA OT LATE TO CLOSE SIA CI FAIL TO CLOSE SIA CT LATE TO OPEN
Annex A:
A1. Scope. The dealer always has the option to override the standard based on the needs of individual subscribers.
CSAA Scope for Handling, edited Page 30 of 30 4/7/2023