SIEMENS Serial Line connection to hiT 7070 / 7050 HiT7070 / hiT7050 / TNMS-CT 2.0 Siemens AG ICN CP E NP J Hofmannstr. 51 81359 Munich NCC Hotline: Tel.: +89 / 722-44666 Fax: +89 / 722-62747 E-Mail: [email protected] Dokument: document.doc
Transcript
Page 1: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

Serial Line connection to hiT 7070 / 7050 HiT7070 / hiT7050 / TNMS-CT 2.0

Siemens AGICN CP E NP JHofmannstr. 5181359 Munich

NCC Hotline:Tel.: +89 / 722-44666Fax: +89 / 722-62747E-Mail: [email protected]: document.doc

Page 2: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

ReleasesThis document concerns the serial connection ("F" interface) to hiT 7070 and 7050 releases

1.02 1.1 2.0

NOTE: Release 1.0 of hiT 7050 does not provide "F" interface support.

SymptomsIn some cases it is not possible to connect from TNMS-CT 2.0 or higher to Surpass hiT 7070/7050 using the serial line.

Problem Description

Surpass 7050 – serial cableThe serial cable used to connect to Surpass hiT 7050 must have a particular pin assignment. Some commercially available "null-modem" cables will work and others will not work, depending on the pin connection of the cable.

WorkaroundUse a serial "null-modem" cable that has only pins 2 and 3 (RX and TX) connected (cross), and pin 5 for ground. All other pins are not connected, as shown in the diagram below:

Ordering number for Siemens cableThere is a Siemens code for the "official" cable for hiT 7050. V42256-R703-A18-1 TPY R0This cable has the following connections:

Pin Pin1 ------------ 12 ------------ 33 ------------ 24 ------------ 45 ------------ 56 ------------ 67 ------------ 78 ------------ 8

This means, pins 2 and 3 are connected crossed, other pins are connected straight. Pin 9 is not used.

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page2/14

Document: document.doc All rights reserved

Page 3: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

The connections are shown in the diagram below.

hiT 7070/ 7050Ordering number for Lindy cable

There have also been successful tests for serial connection to hiT using a commercial "Lindy" brand cable.The ordering number from Lindy for this cable is 31578.

Pins 4 and 9 are not connected. The connections are shown in the diagram below:

More information available under http://www.lindy.com.Using this cable we have successfully tested the "F" interface connection to hiT 7070 as well as 7050.

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page3/14

Document: document.doc All rights reserved

Pin Pin1/6/8 ------------ 7

2 ------------ 33 ------------ 25 ------------ 57 ------------ 1/6/8

Page 4: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

Appendix: Setting up the serial connection.

Procedure from User Manual

Attached the procedure extracted from the TNMS-CT V1.0 User Manual (UMN) Chapter 3.6.1.

If the serial connection in TNMS-CT is already set, check that it is properly configured by comparing the settings shown in the user manual in point 7 of chapter 3.6.1 (see the screenshots in the document attached above).

If the serial connection does not work (fails when trying to connect), it is also recommendable to check the following:

1. MPU-F properties:

Register “General”

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page4/14

Document: document.doc All rights reserved

Page 5: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

Register "Options"

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page5/14

Document: document.doc All rights reserved

Page 6: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

Register "Security"

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page6/14

Document: document.doc All rights reserved

Page 7: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

Register: “Networking”

PPP-Settings:

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page7/14

Document: document.doc All rights reserved

Page 8: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

TCP/IP-properties:

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page8/14

Document: document.doc All rights reserved

Page 9: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

2. OSI Protocol settings in TNMS-CT

notice the "Local IP Address" must be 127.0.0.1 for the serial connection to work.

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page9/14

Document: document.doc All rights reserved

Page 10: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

3. DCN Management in TNMS-CT

From the main TNMS-CT menu choose

Configuration -> DCN management

In this window the first item is the Serial Line Server. Clicking on the server icon displays the four Serial Line Server Channels that are available in TNMS-CT. hiT 7070 and 7050 are QST V2 Network Elements.

Here the NE ("QST V2 Serial Line NE") must exist under the QST V2 Serial Line Channel, as shown in the figure above.

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page10/14

Document: document.doc All rights reserved

Page 11: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

Settings QST V2 Serial Channel:

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page11/14

Document: document.doc All rights reserved

Page 12: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

The NE must have the following properties (click on the item "QST V2 Serial Line NE" with the right-hand mouse button and select the item "Properties")

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page12/14

Document: document.doc All rights reserved

Page 13: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

Register: General

The ID Name need not be changed. It is not mandatory to add any data in this window.

Register: Security

For serial connection with TNMS-CT the following data must be entered

User: LCTPassword : "NEPASSWORD" (all capital letters)

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page13/14

Document: document.doc All rights reserved

Page 14: Ct 0001 SerialConnection HiT7070 7050iss2

SIEMENS

Register: QST

IP Address must be 195.0.0.1T-Selector must be QST

After this press "Apply" to make the changes permanent.

Successful connection

After a successful connection the DCN management must show the NE under the " QST V2 Serial Line Channel" in status "running" (see DCN Management window above). In the Network View the NE must also be shown with a green icon, as shown in the figure below:

Clicking on the icon with the right-hand mouse button open the Element Manager for operation.

Authorized02 13.04.04 Conti/Brunner Name: Mr. Gerhards Serial Connection01 17.12.03 A.Conti ICN CP STS NP J HiT 7050

Issue Modif. Note

Date Name SIEMENS AGInformation and Communication Networks

TNMS-CT 2.0Page14/14

Document: document.doc All rights reserved