3
33-126 NEMA Contactors & Starters Starters Non-reversing and Reversing Cutler-Hammer A200 Line January 2001 Vol. 2, Ref. No. [0142] Size 3 Starter Product Selection Non-reversing, Sizes 00-9 When Ordering Specify Order by Catalog Number from Table 33-191, plus Suffix for coil voltages, verifying usage of appropriate sizes. Heaters Enter heaters as separate item by listing Catalog Number from tables, Pages 33-148 - 33-149, as required per starter. Table 33-191. Non-reversing Starters Selection < Size Amps Max. UL Horsepower 1-Phase 115V 230V 3-Phase 208V 240V 480V 600V 2 Poles® Open Catalog Number® Price U.SS 3 Poles Open Catalog Number® Price U.S. $ Sizes 00-6 00 0 1 1-1/2 2 3 4 5 6 9 18 27 36 45 90 135 270 540 1/3 1 2 3 7-12 1-1/2 3 7-1/2 10 25 40 75 150 1-1/2 3 7-1/2 15 30 50 100 200 2 5 10 25 50 100 200 400 2 5 10 25 50 100 200 400 A200MABR A200MOBR A200M1BR A200MDBR A200M2BR 193. 217. 279. 330. 505. A200MAC_ A200MOC_ A200M1C_ A200M2C. A200M3C. A200M4C. A200M5C_ A200M6C. 193. 242. 279. 505. 820. 1,870. 4,565. 10,840. Sizes 7- 9 810 1215 2250 200 400 300 450 800 600 900 1600 600 900 A200M7C, A200M8C, A200M9C_ ® 16,100. 24,100. 38,900. 'i> For ambient compensated overload relay with auto-reset, add Suffix D. ® Sizes 7-9 use rectifier with DC coil. S Single-phase with one single-pole overload relay. £' For Size 9, only available coil voltage is 120V. Table 33-192. Coils for Sizes 00-6 Coil Volts and Hz Code Suffix 120/60 or 110/50 200 - 208/60 240/60 480/60 600/60 AC B W X E Table 33-193. Coils for Sizes 7,8 and 9 © Coil Volts and Hz Code Suffix 110 -120/50 or 60 220 - 240/50 or 60 440 - 480/50 or 60 600/60 J W X E ® For Size 9, only available coil voltage is 120V. Factory Modifications..... Page 33-133 Modification Kits, Accessories............ Pages33-133-33-135 Dimensions .............. Page 33-123 Discount Symbol ......... 1CD1 F:T*N For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E
Transcript
Page 1: Cutler-Hammer - DLE ELECTRIC SUPPLY - Electrical ...dlelectricsupply.com/files/A200M1CBP.pdfCutler-Hammer January 2001 Vol. 2, Ref No. [0137] NEMA Contactors & Starters Starters —

33-126 NEMA Contactors & StartersStarters — Non-reversing and Reversing

Cutler-Hammer

A200 Line

January 2001Vol. 2, Ref. No. [0142]

Size 3 Starter

Product Selection —Non-reversing, Sizes 00-9When Ordering SpecifyOrder by Catalog Number from Table33-191, plus Suffix for coil voltages,verifying usage of appropriate sizes.

HeatersEnter heaters as separate item bylisting Catalog Number from tables,Pages 33-148 - 33-149, as requiredper starter.

Table 33-191. Non-reversing Starters Selection<

Size Amps Max. UL Horsepower1-Phase115V 230V

3-Phase208V 240V 480V 600V

2 Poles®OpenCatalogNumber®

PriceU.SS

3 PolesOpenCatalogNumber®

PriceU.S. $

Sizes 00-600

011-1/2

234

56

918

27

36

45

90

135

270

540

1/31

2

3

7-12

1-1/2

37-1/2

1025

40

75

150

1-1/23

7-1/2

153050

100

200

2

5

10

25

50100200400

25

10—

2550

100200400

A200MABRA200MOBRA200M1BRA200MDBRA200M2BR————

193.

217.

279.

330.

505.

A200MAC_A200MOC_A200M1C_—A200M2C.A200M3C.A200M4C.A200M5C_A200M6C.

193.242.279.

—505.820.

1,870.4,565.

10,840.Sizes 7- 97®8®9®

81012152250

———

———

200400

300

450

800

600

9001600

600900—

———

———

A200M7C,A200M8C,A200M9C_ ®

16,100.24,100.38,900.

'i> For ambient compensated overload relay with auto-reset, add Suffix D.® Sizes 7-9 use rectifier with DC coil.S Single-phase with one single-pole overload relay.£' For Size 9, only available coil voltage is 120V.

Table 33-192. Coils for Sizes 00-6Coil Volts and Hz Code Suffix

120/60 or 110/50200 - 208/60240/60480/60600/60

ACB

WXE

Table 33-193. Coils for Sizes 7,8 and 9 ©Coil Volts and Hz Code Suffix

110 -120/50 or 60220 - 240/50 or 60440 - 480/50 or 60600/60

JWXE

® For Size 9, only available coil voltage is120V.

Factory Modifications..... Page 33-133Modification Kits,Accessories............ Pages33-133-33-135

Dimensions.............. Page 33-123Discount Symbol......... 1CD1

F:T*N For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E

Page 2: Cutler-Hammer - DLE ELECTRIC SUPPLY - Electrical ...dlelectricsupply.com/files/A200M1CBP.pdfCutler-Hammer January 2001 Vol. 2, Ref No. [0137] NEMA Contactors & Starters Starters —

Cutler-HammerJanuary 2001Vol. 2, Ref No. [0137]

NEMA Contactors & StartersStarters — Non-reversing and Reversing 33-121

A200 Line

ContentsDescription

Starters — Non-reversing andReversing . . . . . . . . . . . . . . .

Product Description —Sizes 00-4............

Product Description —Sizes 5-9. . . . . . . . . . . . .

Features and Benefits ....Instructional Leaflets . . . . .Dimensions and

Shipping Weights . . . . . .Product Selection —

Non-reversing,Sizes 00 -9 . . . . . . . . . . . .

Product Selection —Reversing,Sizes 00-9. . . . . . . . . . . .

Starters — Two-Speed......Technical D a t a . . . . . . . . . . . . .Factory Modifications.......Accessories and Field

Modification Kits . . . . . . . . .Renewal Parts . . . . . . . . . . . .

Page

33-121

33-121

33-12133-12233-122

33-123

33-126

33-12733-12833-12933-133

33-13333-136

Size 1 Starter

Product Description —Sizes 00-4GeneralMagnetic starters are used for full-voltage, across-the-line starting andstopping of squirrel cage motors. Theycan be operated locally or remotely bymanual or automatic pilot devices.

NEMA Sizes 00-4;Three-Phase, 1-1/2 -100 hpThese starters use Class A201 contac-tors as described on Page 33-115.Contactor features are enhancedthrough the ability to provide positivemotor protection in the form of severaltypes of overload relays. See Pages33-141-33-149

Type B Overload Relay, Manual Reset OnlySupplied as standard on Class A200and A900 starters (two-speed). The bi-metallic overload relay offers ambientcompensation and trip-to-test feature(relay contact status check) as stan-dard. In addition, an isolated normally-open contact is available in kit form forcustomer mounting. Type B overloadrelays are manual reset only.

Type A Overload Relay, Manualor Automatic ResetThis is an optional overload relay,offering the capability of field conver-sion to automatic reset. It is availableas an ambient compensated or non-compensated type.

Non-reversing StartersNon-reversing starters are supplied asopen devices. All starters are suppliedwith a normally-open holding circuitinterlock.

Class A200 starters are available as ULlisted or recognized components, aswell as with CSA certification.

Reversing StartersFor reversing applications (ClassA210), a starter and a contactor electri-cally and mechanically interlocked aresupplied on a common baseplate.Reversing starters are used to start,stop and reverse AC squirrel cagemotors and for primary control ofreversing wound-rotor motors.

For plugging or inching, when opera-tions exceed five times per minute,decreased horsepower ratings inaccordance with NEMA Standard ICS2-321 are recommended.

Two-Speed Starters, A900sFor across-the-line starting of two-speed constant hp, constant torqueand variable torque squirrel cagemotors, two-speed starters (ClassA900) are available. These startersconsist of two starters, one for eachmotor speed, mechanically and electri-cally interlocked and wired for manualspeed selection by means of pushbut-tons. Auxiliary relays may be added toprovide automatic acceleration ordeceleration.

Starters for two-speed, two indepen-dent winding motors consist of two-,three- or four-pole starters electricallyand mechanically interlocked. Startersfor two-speed, single reconnectablewinding motors consist of one three-pole and one five-pole starter mechan-ically and electrically interlocked.

Size 5 Starter

Product Description —Sizes 5-9NEMA Sizes 5-9;Three-Phase 75 to 1600 hpNon-reversing (Class A200), andreversing (Classes A210, A250) fullvoltage starters are used for across-the-line starting of squirrel cage induc-tion motors. They are used withmotors rated above 50 hp at 230V, andabove 100 hp at 460 through 600V.

Sizes 5 and 6 starters use Class A201contactors as described on Page 33-1 1 6 . In addition to standard motorstarters, special application devicesare available: Sizes 5 and 6 starterswith integrally rectified AC to DC coilsfor applications where low voltageproblems are prevalent are available.

Class A200 starters are UL listedand recognized and also carry CSAcertification.

Front Removable Parts — All operat-ing parts can be removed quickly andeasily from the front. Straight-throughwiring and conveniently located con-nection points for external wires andcables minimize installation time.

Type B Block Type Thermal OverloadRelay — Dependable overload protec-tion is assured by these snap-action,manual reset relays. Automatic resetType A relays are available as anoption.

Technical Data Pages 33-129-33-132

CAT.201.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog E:T«N

Page 3: Cutler-Hammer - DLE ELECTRIC SUPPLY - Electrical ...dlelectricsupply.com/files/A200M1CBP.pdfCutler-Hammer January 2001 Vol. 2, Ref No. [0137] NEMA Contactors & Starters Starters —

33-132 NEMA Contactors & StartersTechnical DataA200 Line

Cutler-HammerJanuary 2001

Vol. 2, Ret No. [01481

Combination RatingsTable 33-209. Combination Ratings — Sizes 00-2Short-CircuitProtective Device(SCPD)

Max.RatingSCPD

Circuit BreakerInterruptingRating

Short-CircuitWithstand CapabilityCurrent Voltage

Sizes 00,0,1Class H FuseClass J FuseClass R FuseClass T FuseMagnetic Only®Type CB £

Thermal/Mag.Type CB 3)

Magnetic OnlyTypeCB + CL®Thermal/Mag.Type CLB ®

60A60A60A60A30A

50A

30A

BOA

Marked HMCP

65.000A25,OOOA

100.000A35.000A

HMCP +Current Limiter150,OOOA

5,OOOA100.000A100.000A100,OOOA100.000A50.000A65.000A25.000A

100.000A35.000A

100,OOOA

100.000A

600V600V600V600V480V600V480V600V480V600V600V

480V

Size 2Class H FuseClass J FuseClass R FuseClass T FuseMagnetic Only ©Type CB ®

Thermal/Mag.Type CB 'S

Magnetic OnlyTypeCB + CL®Thermal/Mag.Type CLB ®

100A100A100A100A50A

90A

BOA

50A

Marked HMCP

65.000A25.000A

100.000A35.000A

HMCP +Current Limiter150,OOOA

5,OOOA100.000A100.000A100,OOOA100,OOOA50.000A65.000A25,OOOA

100.000A35,OOOA

100,000 A

100.000A

600V600V600V600V480V600V480V600V480V600V600V

480V

® Instantaneous Adjustable Trip.® Circuit Breaker.® Inverse Time Circuit Breaker.® Instantaneous Adjustable Trip with Current Limiting Attachment.® Inverse Time with Built-in Current Limiting Attachment.

Coil SuffixTable 33-211. Other Available Coil Voltages — AC and DC CoilsCoils

AC

DC®®®

CatalogNumberSuffix

ABC®DEGH1J

K

LM

Coil Rating(Volts/Hertz)

120/60,110/50200-208/60240/60 and 480/60440/50600/60 Hz220/50380/5024/60110-120/50 or60 Reel, to DC

220-240/50 or60 Rect. to DC

24V DC48V DC

CatalogNumberSuffix

NPQ®R®U

VwXYz

sT

Coil Rating(Volts/Hertz)

110/5048/60AC/DC Volts Specified120/60 and 240/60440-480/50 or60 Rect. to DC

110/60240/60480/60415/50277/60

125V DC250V DC

® List Price Addition for dual voltage coils. Consult Sales Office or Price List.® List Price Addition for DC coils. Consult Sales Office or Price List.® DC coils for Size 5 and 6 contactors and starters are intermittent duty

rated only. A mechanical latch is required.© DC coils. Use only on contactors originally supplied with a DC coil.© For Q suffixes "order by description" consult Technical Support Center.

Table 33-210. Combination Ratings — Sizes 3 and 4Short-CircuitProtective Device(SCPD)

Max.RatingSCPD

Circuit BreakerInterruptingRating

Short-CircuitWithstand CapabilityCurrent Voltage

Size3Class H FuseClass J FuseClass R FuseClass T FuseMagnetic Only®Type CB ®

Thermal/Mag.TypeCB®

Magnetic OnlyType CB + CL ®Thermal/Mag.TypeCLB®

60A60A60A60A

100A

150A

100A

150A

Marked HMCP

65.000A25,OOOA

100.000A35.000A

HMCP +Current Limiter50.000A

5.000A100.000A100.000A100.000A100.000A50.000A65.000A25.000A

100.000A35,OOOA

100.000A

100.000A

600V600V600V600V480V600V480V600V480V600V600V

480V

Size 4Class H FuseClass J FuseClass R FuseClass T FuseMagnetic Only®Type CB <i>Thermal/Mag.Type CB ®

Magnetic OnlyType CB + CL ®Thermal/Mag.Type CB + CL ®Thermal/Mag.TypeCLB®

400A400A400A400A150A

250A

150A

250A

250A

Marked HMCP

65.000A25.000A

100.000A35.000A

HMCP +Current Limiter200.000A

150.000A

10.000A100.000A100.000A100.000A100.000A50.000A65.000A25,OOOA

100.000A35.000A

100.000A

100.000A

100.000A

600V600V600V600V480V600V480V600V480V600V600V

600V

480V

® Instantaneous Adjustable Trip.© Circuit Breaker.® Inverse Time Circuit Breaker.® Instantaneous Adjustable Trip with Current Limiting Attachment.® Inverse Time with Built-in Current Limiting Attachment.® Inverse Time Current Limiting Breaker.

Table 33-212. Other DC Coils Available (For Q Suffix) ©Voltages

1228323437.54050

Sizes 0 & 11-to4-Pole

Size 21-to3-Pole

Style Number

1268C86G071268C86G061268C86G091268C86G161268C86G171268C86G131268C86G10

Voltages

79

96

200

300

315

125/250

Sizes 0 & 11-to4-Pole

Size 21-to3-Pole

Style Number

1268C86G081268C86G151268C86G111268C86GH1268C86G121268C86G03—

For Q suffixes "order by description" consult Technical Support Center.

F:T*N For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E


Recommended