DATA CENTERNETWORKING TOPOLOGIES
2
OVERVIEW
Data Center Physical Layout Data Center Network Topologies ToR vs. EoR Data Center Networking Issues Data Center Networking Requirements
3
DATA CENTER STANDARDS
ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers
Published 2005 – available through TIA at www.tiaonline.org
ANSI/NECA/BICSI-002 Data Center Design and Implementation Best Practices
complements TIA-942 –2007
4
PURPOSE OF TIA-942
Encourage early participation of telecom designers in data center design process
Fill a void by providing standards for planning of data centers, computer rooms, serverrooms, and similar spaces.
The standard encompasses much more thanjust telecommunications infrastructure.
Close to half of the technical content deals with facility specifications.
5
PURPOSE OF TIA-942
Define a standard telecommunications infrastructure for data centers Structured cabling system for data centers using
standardized architecture and media Accommodates a wide range of applications
(LAN, WAN, SAN, channels, consoles) Accommodates current and future protocols
(e.g., 10+ GbE (Giga bit Ethernet) ) Replaces unstructured point-to-point cabling that
uses different cabling for different applications
6
DESIGN ELEMENTS
1. Cabling Design2. Facility Design3. Network Design
7
CABLING AND FACILITY DESIGN
Cabling Design: Copper and fiber cabling performance Connectors, cables, distribution hardware Cabling distances Space management
Facility Design: Data center sizing Power distribution methodologies Pathways and spaces HVAC, security, operations, and
administration. Flexibility, scalability, reliability and space
management
8
NETWORK DESIGN:
Support of legacy systems Enable rapid deployment of new and
emerging technologies such as 10 GbE and 10+ GbE
copper and fiber applications.
9
GOOGLE DATA CENTER
Take a walk through a Google data center
http://www.google.com/about/datacenters/inside/streetview/
10
COOLING PLANT
11
MODULAR DATA CENTERS
Called Ice cube Small: < 1 MW, 4 racks per unit Medium: 1-4 MW, 10 racks per unit Large: > 4 MW, 20 racks per unit Built-in cooling, high PUE (power usage effectiveness) 1.02
PUE = Power In/Power Used. It means cooling use 2 percent of power. Not efficiency of 0.98!
Rapid deployment
12
CONTAINERIZED DATA CENTER
All companies like IBM and cisco make it like this
13
UNSTRUCTURED CABLING
14
STRUCTURED CABLING
15
EQUIPMENT CABINETS
Three Layers: 1. Bottom: Signaling (Ethernet),2. Middle: Power and 3. Top: Fiber
Minimize patching between cabinets and racks
16
DATA CENTER PHYSICAL LAYOUT
17
ANSI/TIA-942-2005 STANDARD
18
ANSI/TIA-942-2005 STANDARD Computer Room: Main servers Entrance Room: Data Center to external cabling Cross-Connect: Enables termination of cables Main Distribution Area (MDA): Main cross connect.
Central Point of Structured Cabling. Core network devices
Horizontal Distribution Area (HDA): Connections to active equipment.
Equipment Distribution Area (EDA): Active Servers+Switches.
Zone Distribution Area (ZDA): Optionally between HDA and EDA. Rack, cabinet, or under floor enclosure that houses a zone outlet (ZO) or consolidation point (CP)
Backbone Cabling: Connections between MDA, HDA, and Entrance room
19
ZONE DISTRIBUTION AREA
20
DATA CENTER NETWORK TOPOLOGIES
Three levels of switches: Core, Aggregation, Access
21
DATA CENTER NETWORKS 20-40 servers per rack Each server connected to 2 access switches
with 1 Gbps (10 Gbps becoming common) Access switches connect to 2 aggregation
switches Aggregation switches connect to 2 core routers Aggregation layer is the transition point
between L2-switched access layer and l3-routed core layer
Low Latency: In high-frequency trading market, a few microseconds make a big difference.
Cut-through switching and low-latency specifications.
22
DATA CENTER NETWORKS (CONT)
Edge routers manage traffic between aggregation routers and in/out of data center
All switches below each pair of aggregation switches form a single layer-2 domain
Each Layer 2 domain typically limited to a few hundred servers to limit broadcast
Most traffic is internal to the data center. Network is the bottleneck. Uplinks utilization
of 80% is common. Most of the flows are small. Mode = 100 MB.
DFS (Distributed File System) uses 100 MB chunks.
23
SWITCH LOCATIONS
24
TOR VS EOR
ToR: Advantages:
Easier cabling If rack is not fully populated unused ToR ports
DisAdvantages: If rack traffic demand is high, difficult to add more
ports Upgrading (1G to 10G) requires complete Rack upgrade
EoR: Disadvantages
Longer cables Advantages:
Severs can be place in any rack Ports can easily added, upgraded
25
HIERARCHICAL NETWORK DESIGN All servers require application delivery
services for security (VPN, Intrusion detection, firewall), performance (load balancer), networking (DNS, DHCP(Dynamic Host Control Protocol), NTP (Network Time Protocol), FTP, RADIUS (Remote Access Dial-In User Service server to perform authentication ), Database services (SQL)
Stateful devices (firewalls) on Aggregation layer
26
DATA CENTER ACCESS LAYER DESIGN
4 Possibilities:1. Looped Triangle2. Looped Square3. Loop Free U4. Looped Free Inverted U
27
ACCESS AGGREGATION CONNECTIONS
28
CISCO USES ICONS TO REPRESENT DIFFERENT NETWORKING DEVICES
29
DATA CENTER NETWORKING ISSUES
30
DATA CENTER NETWORKING ISSUES (CONT)
Under-utilization. Even when multiple paths exist only one is used.
ECMP (Equal Cost Multipath) is used by routers to spread traffic to next hops using a hash function. However, only 2 paths exist.
31
DCN REQUIREMENTS
Needs to be Scalable, Secure, Shared, Standardized, and Simplified (5 S's)
Converged Infrastructure: Servers, storage, and network have to work together
Workload Mobility: Large L2 domains required for VM mobility
East-West Traffic: Significant server-to-server traffic as compared to server to user. One Facebook request required 88 cache looks, 35 database lookups, 392 backend RPC calls. Intranet traffic 935X the http request/response
Storage traffic on Ethernet: Congestion management on Ethernet
32
4-POST ARCHITECTURE AT FACEBOOK Each rack contains a rack switch (RSW) with
up to forty-four 10G downlinks and four or eight 10G uplinks (typically 10:1 oversubscription) one to each cluster switch (CSW)
A cluster is a group of four CSWs and the corresponding server racks and RSWs
33
4-POST ARCHITECTURE AT FACEBOOK (CONT) Each CSW has four 40G uplinks (10G×4), one to each of
four “FatCat” aggregation switches (typically 4:1 oversubscription).
The four CSWs in each cluster are connected in an 80G protection ring (10G×8) and the four FC switches are connected in a 160G protection ring (10G×16)
network failures used to be one of the primary causes of service outages. The additional redundancy in 4-post has made such outages rare.
traffic that needed to cross between clusters used to traverse expensive router links. The addition of the FC tier greatly reduced the traffic through such links.
All tiers are switched and not routers Ref: N. Farringon and A. Andreyev, “Facebook’s Data Center Network Architecture,” 2013
IEEE Optical Interconnect Conference, http://nathanfarrington.com/papers/facebook-oic13.pdf
34
MAIN DISADVANTAGES OF 4-POST
1. A CSW failure reduces intra-cluster capacity to 75%
2. The cluster size is dictated by the size of the CSW
3. Large switches are produced in smaller volumes from fewer manufacturers
4. Large switches are often oversubscribed internally, meaning that not all of the ports can be used simultaneously
5. Large switches are often very proprietary. This can lead to months and years between bug fixes
35
CLOS NETWORKS
36
FAT-TREE Fat-Tree networks were proposed by
Charles E. Leiserson in 1985. Such network is a tree, and processors are connected to the bottom layer.
The distinctive feature of a fat-tree is that for any switch, the number of links going down to its siblings is equal to the number of links going up to its parent in the upper level
Therefore, the links get “fatter” towards the top of the tree, and switch in the root of the tree has most links compared to any other switch below it:
37
FOR ENTERPRISE NETWORKS
However, for enterprise networks that connect servers, commodity (off-the-shelf) switches are used, and they have a fixed number of ports. Hence, the design of fat-tree, where the number of ports varies from switch to switch, is not very usable.
Therefore, alternative topologies were proposed that can efficiently utilize existing switches with their fixed number of ports.
There is a controversy whether such topologies should be called fat-trees, or rather “(folded) Clos networks”, or anything else.
However, the term fat-tree is widely used to describe such topologies.
38
TWO-LEVEL FAT-TREE NETWORK.
39
SUMMARY
1. Modular data centers can be used for easy assembly and scaling
2. Three tiers: Access, Aggregation, Core3. Application delivery controllers between
Aggregation and core4. Need large L2 domains5. Fat-tree topology is sometimes used to
improve performance and reliability