+ All Categories
Home > Documents > D Wjb41g1zx5x02d2yay1t1p3ix-wpengine.netdna-ssl.com/... · "d" "w" 1.3125 flange width, all sides...

D Wjb41g1zx5x02d2yay1t1p3ix-wpengine.netdna-ssl.com/... · "d" "w" 1.3125 flange width, all sides...

Date post: 28-Jun-2020
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
1
"H" "D" "W" 1.3125 FLANGE WIDTH, ALL SIDES A C C E S S V I E W F L A N G E C O N N E C T I O N "H" HEIGHT WIDTH "W" 05W 14 1/8" 10W 26 1/8" 15W 37 1/2" 20W 49 1/2" 25W 60 7/8" 30W 72 7/8" 35W 84 1/4" 40W 96 1/4" SIZE CODES STANDARD SPECS: 1. UNIT SHALL BE MANUFACTURED FROM 16 GA. MATERIAL. ALUMINUM EXTRUSION TRACKS SHALL HAVE A NYLON PILE SEAL FOR SEALING THE FILTER EDGES. NEOPRENE GASKET SHALL SEAL DOOR EDGES. POLYURETHANE FOAM INSIDE ACCESS DOOR GASKETS FILTERS TO PREVENT BYPASS. DOORS ARE FITTED WITH POSITIVE PRESSURE TRIP LOCK LATCHES. 2. UNIT IS DESIGNED TO ACCOMMODATE: 2" OR 4" NOM. PREFILTERS OR A COMBINATION OF BOTH. 3. UNITS OVER 40W CAN BE PRODUCED BY COMBINING SMALLER UNITS TOGETHER. TO FIND THE WIDTH OF THOSE UNITS, ADD THE WIDTHS OF THE TWO SMALLER UNITS TOGETHER AND SUBTRACT 2-1/2". IE: A 60W UNIT WOULD BE (2) 30W UNITS TOGETHER, TO FIND WIDTH: 72-7/8" + 72-7/8" - 2-1/2" FOR A WIDTH OF 143-1/4". 4. UNITS THAT ARE TO BE VERTICAL FLOW WILL COME EQUIPPED WITH SAFETY CHAINS ON DOORS. (ONE PER DOOR) DOOR WILL ALLWAYS BE HINGED ON LOWER SIDE OF HOUSING WITH CHAIN ATTACHED TO DOOR AND LATCH SIDE. ** DEMISTER UNIT SHALL BE SAME AS ABOVE BUT WILL USE 16 GA U-TRACK INSTEAD OF ALUMINUM EXTRUSION TO HOLD FILTERS AND WILL HAVE 1/2" NPT HALF COUPLING WITH PLUG AS SHOWN IN DETAIL 'A.' C U S T O M E R I N F O R M A T I O N 05H 14 7/8" 10H 26 7/8" 15H 39" 20H 51" 25H 63 1/8" 30H 75 1/8" 35H 87 1/4" 40H 99 1/4" ORDER DETAILS ITEM# EX. S T A T I C P R E S S U R E P O R T S (REF. CSD-020) PORTS ONLY (PLUGGED) WITH GAGES FACTORY MOUNTED SHIP LOOSE DEPTH "D" 8 1/2" 12" MAXIMUM PREFILTER HOLDING CAPABILITY 2" OR 4" 2" AND 4" U N L E S S O T H E R W I S E S P E C I F I E D FRACTION: ALL DIMENSIONS ARE IN INCHES DECIMAL: TOLERANCES ARE: DRAWING NO.: D I M S C A L E : REV. APPR. BY DATE DRAWN BY REV. DESCRIPTION: DATE DRAWN BY: T E X T H E I G H T : DWG SCALE: DATE: APPROVED BY: DATE: OF SHEET SALES DRAWING ANGULAR: NTS ±1° ±.125" ±1/8" 24 0 1 1 6/29/10 JWW 5/7/2010 WMA CSD-001 INNER SEAL 02 04 24 HOUSINGS IF YOU DO NOT SEE THE OPTIONS YOU REQUIRE, THE MANUFACTURER CAN CUSTOM DESIGN YOUR HOUSING TO NEARLY ANY SIZE AND SPECIFICATION. SIZE CODE NOTE : TO DETERMINE SIZE CODE OF DESIRED HOUSING, 05 SIZED UNITS REPRESENT A 12" NOMINAL SIZE FILTER AND 10 SIZED UNITS REPRESENT A 24" NOMINAL SIZED FILTER. IE: A 10HX15W UNIT WOULD ACCOMMODATE (1) 24"X24" NOMINAL FILTER AND (1) 24"X12" NOMINAL FILTER PLACED SIDE BY SIDE. MAGNEHELIC 2000 SERIES PHOTOHELIC A3000 SERIES RANGE: _______________ RANGE: _______________ AIR FLOW D E T A I L ' A ' 1/2" NPT DRAIN DEMISTER ONLY 3/8" TUBING TO CONNECT TRACKS FROM MULTIPLE LEVELS 16 GA. 'U'-TRACK DETAIL 'A' A I R F L O W 1 2 3 4 5 (CHECK IF APPLICABLE) S T A N D A R D O P T I O N S 11 QTY. REQ'D WIDTH HEIGHT DEPTH 15W 20H 12 D O O R S 2 DOORS (STANDARD) 1 DOOR F L A N G E S PLAIN (STANDARD) DRILLED (REF. CSD-016) UPSTREAM DOWNSTREAM T R A N S I T I O N S UPSTREAM DOWNSTREAM SQUARE COLLAR: H/W ____X____ ROUND COLLAR: ID _________ RIGHT HAND LEFT HAND (SPECIFY ACCESS) M A T E R I A L GALVANIZED STEEL T-304L STAINLESS T-316L STAINLESS ALUMINIZED STEEL P R E F I L T E R S I Z E 2" (NOM.) 4" (NOM.) MULTI-STAGE 2" AND 4" (NOM) L GRADE T-316L STAINLESS I N S U L A T I O N 2" THICK, FOIL BACKED, W E A T H E R C O V E R YES L I F T I N G L U G S 2 4 H I G H T E M P G A S K E T YES DOUBLE WALL D E M I S T E R U N I T * * YES WEATHER PROOF GAGE BOX
Transcript
Page 1: D Wjb41g1zx5x02d2yay1t1p3ix-wpengine.netdna-ssl.com/... · "d" "w" 1.3125 flange width, all sides access view flange connection "h" height width "w" 05w 14 1/8" 10w 26 1/8" 15w 37

"H"

"D" "W"

1.3125 FLANGEWIDTH, ALL SIDES

ACCESS VIEW FLANGE CONNECTION

"H"HEIGHT

WIDTH"W"

05W

14 1/8"

10W

26 1/8"

15W

37 1/2"

20W

49 1/2"

25W

60 7/8"

30W

72 7/8"

35W

84 1/4"

40W

96 1/4"

SIZE CODES

STANDARD SPECS:

1. UNIT SHALL BE MANUFACTURED FROM 16 GA. MATERIAL. ALUMINUM EXTRUSION TRACKS SHALL HAVE A NYLON PILE SEAL FOR SEALING THE FILTER EDGES. NEOPRENE GASKET SHALL SEAL DOOR EDGES. POLYURETHANE FOAM INSIDE ACCESS DOOR GASKETS FILTERS TO PREVENT BYPASS. DOORS ARE FITTED WITH POSITIVE PRESSURE TRIP LOCK LATCHES.2. UNIT IS DESIGNED TO ACCOMMODATE: 2" OR 4" NOM. PREFILTERS OR A COMBINATION OF BOTH.3. UNITS OVER 40W CAN BE PRODUCED BY COMBINING SMALLER UNITS TOGETHER. TO FIND THE WIDTH OF THOSE UNITS, ADD THE WIDTHS OF THE TWO SMALLER UNITS TOGETHER AND SUBTRACT 2-1/2". IE: A 60W UNIT WOULD BE (2) 30W UNITS TOGETHER, TO FIND WIDTH: 72-7/8" + 72-7/8" - 2-1/2" FOR A WIDTH OF 143-1/4".4. UNITS THAT ARE TO BE VERTICAL FLOW WILL COME EQUIPPED WITH SAFETY CHAINS ON DOORS. (ONE PER DOOR) DOOR WILL ALLWAYS BE HINGED ON LOWER SIDE OF HOUSING WITH CHAIN ATTACHED TO DOOR AND LATCH SIDE.

** DEMISTER UNIT SHALL BE SAME AS ABOVE BUT WILL USE 16 GA U-TRACK INSTEAD OF ALUMINUM EXTRUSION TO HOLD FILTERS AND WILL HAVE 1/2" NPT HALF COUPLING WITH PLUG AS SHOWN IN DETAIL 'A.'

CUSTOMER INFORMATION

05H 14 7/8"10H 26 7/8"15H 39"20H 51"25H 63 1/8"30H 75 1/8"35H 87 1/4"40H 99 1/4"

ORDER DETAILS

ITEM#

EX.

STATIC PRESSURE PORTS(REF. CSD-020)

PORTS ONLY (PLUGGED)

WITH GAGES

FACTORY MOUNTED

SHIP LOOSEDEPTH"D"

8 1/2"12"

MAXIMUM PREFILTERHOLDING CAPABILITY2" OR 4"2" AND 4"

UNLESS OTHERWISE SPECIFIED

FRACTION:

ALL DIMENSIONS ARE IN INCHES

DECIMAL:TOLERANCESARE: DRAWING NO.:

DIM

SCAL

E:

REV.

APPR. BYDATE

DRAWN BYREV. DESCRIPTION: DATE

DRAWN BY:

TEXT

HEI

GH

T:

DWG SCALE:DATE:

APPROVED BY: DATE: OFSHEET

SALES DRAWING

ANGULAR:

NTS

±1°±.125"±1/8"

24

0116/29/10JWW

5/7/2010WMA

CSD-001

INNER SEAL 02 04 24 HOUSINGS

IF YOU DO NOT SEE THE OPTIONS YOU REQUIRE, THE MANUFACTURER CAN CUSTOM DESIGN YOUR HOUSING TO NEARLY ANY SIZE AND SPECIFICATION.

SIZE CODE NOTE: TO DETERMINE SIZE CODE OF DESIRED HOUSING, 05 SIZED UNITS REPRESENT A 12" NOMINAL SIZE FILTER AND 10 SIZED UNITS REPRESENT A 24" NOMINAL SIZED FILTER. IE: A 10HX15W UNIT WOULD ACCOMMODATE (1) 24"X24" NOMINAL FILTER AND (1) 24"X12" NOMINAL FILTER PLACED SIDE BY SIDE.

MAGNEHELIC 2000 SERIES

PHOTOHELIC A3000 SERIESRANGE: _______________

RANGE: _______________AIR

FLOW

DETAIL 'A'1/2" NPT DRAIN

DEMISTER ONLY

3/8" TUBING TO CONNECT TRACKS

FROM MULTIPLE LEVELS

16 GA. 'U'-TRACK

DETAIL'A'

AIR FLOW

1

2

3

4

5

(CHECK IF APPLICABLE)STANDARD OPTIONS

11

QTY.REQ'DWIDTHHEIGHT DEPTH

15W20H 12

DOORS2 DOORS (STANDARD)

1 DOOR

FLANGESPLAIN (STANDARD)

DRILLED (REF. CSD-016)

UPSTREAM

DOWNSTREAM

TRANSITIONSUPSTREAM

DOWNSTREAM

SQUARE COLLAR: H/W ____X____

ROUND COLLAR: ID _________

RIGHT HAND

LEFT HAND

(SPECIFY ACCESS)

MATERIALGALVANIZED STEEL

T-304L STAINLESS

T-316L STAINLESS

ALUMINIZED STEEL

PREFILTER SIZE2" (NOM.)

4" (NOM.)

MULTI-STAGE 2" AND 4" (NOM)

L GRADE T-316L STAINLESS

INSULATION2" THICK, FOIL BACKED,

WEATHER COVERYES

LIFTING LUGS2

4

HIGH TEMP GASKETYES

DOUBLE WALL

DEMISTER UNIT**YES

WEATHER PROOF

GAGE BOX

Recommended