AC centrifugal fanforward curved, dual inletwith housing (without flange)
D2E133-AM47-94
ebm-papst Mulfingen GmbH & Co. KGBachmühle 2 · D-74673 MulfingenPhone +49 7938 81-0Fax +49 7938 [email protected] partnership · Headquarters MulfingenCounty court Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters MulfingenCounty court Stuttgart · HRB 590142
Nominal data
Type D2E133-AM47-94Motor M2E068-DF
Phase 1~ 1~ 1~ 1~Nominal voltage VAC 230 230 230 230Frequency Hz 50 50 60 60
Type of data definition ml fa ml mlValid for approval / standard UL 2111Speed min-1 1830 1500 1800 1800Power input W 165 190 200 210Current draw A 0.73 0.84 0.88 0.92Motor capacitor µF 3 3 3 3Capacitor voltage VDB 450 450 450 450Capacitor standard ULMin. back pressure Pa 80 0 100 100Min. ambient temperature °C -25 -25 -25 -25Max. ambient temperature °C 50 35 25 25Starting current A 0.9 0.9 0.9ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unitSubject to alterations
Item no. 10430-5-9980 · Revision 66668 · Release 2010-08-26 · Page 1 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC centrifugal fanforward curved, dual inletwith housing (without flange)
D2E133-AM47-94
Technical features
Mass 3.48 kgSize 133 mmSurface of rotor Partially cast in aluminiumMaterial of impeller Sheet steel, hot-galvanisedHousing material Sheet steel, hot-galvanisedMotor suspension Motor mounted via brackets on one sideDirection of rotation Clockwise, seen on rotorType of protection IP 44; Depending on installation and positionInsulation class "B"Humidity class F0Max. permissible ambient motortemp. (transp./ storage)
+ 80 °C
Min. permissible ambient motortemp. (transp./storage)
- 40 °C
Mounting position AnyCondensate discharge holes NoneOperation mode S1Motor bearing Ball bearingTouch current acc. IEC 60990(measuring network Fig. 4, TNsystem)
< 0.75 mA
Motor protection Thermal overload protector (TOP) wired internallyCable exit AxialProtection class I (if protective earth is connected by customer)Product conforming to standard EN 60335-1; CE
Item no. 10430-5-9980 · Revision 66668 · Release 2010-08-26 · Page 2 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC centrifugal fanforward curved, dual inletwith housing (without flange)
D2E133-AM47-94
Product drawing
1 Connection line PVC, 4x brass lead tips crimped
Connection screen
U1 blue Z brown U2 blackPE green/yellow
Item no. 10430-5-9980 · Revision 66668 · Release 2010-08-26 · Page 3 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC centrifugal fanforward curved, dual inletwith housing (without flange)
D2E133-AM47-94
Charts: Air flow 50 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]750700650600550500450400350300250200150100500
qv[cfm]450400350300250200150100500
]aP[sf p
380370360350340330320310300290280270260250240230220210200190180170160150140130120110100
908070605040302010
0
pfs
_E[IN
H2O
]
1,5
1,45
1,4
1,35
1,3
1,25
1,2
1,15
1,1
1,05
1
0,95
0,9
0,85
0,8
0,75
0,7
0,65
0,6
0,55
0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0
]aP[s
f p
1
2
3
4
Measurement: LU-105263
Air performance measured as per ISO 5801Installation category A. For detailedinformation on the measuring set-up, pleasecontact ebm-papst. Suction-side noiselevels: LwA measured as per ISO 13347 /LpA measured with 1m distance to fan axis.The values given are valid under themeasuring conditions mentioned above andmay vary according to the actual installationsituation. With any deviation from thestandard set-up, the specific values have tobe checked and reviewed with the unitinstalled.
Measured values
1234
UV230230230230
fHz50505050
nmin-1
1500189023102570
Pe
W190164141118
IA0.840.720.610.52
qvm3/h710640460295
pfs
Pa0100200275
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase
Item no. 10430-5-9980 · Revision 66668 · Release 2010-08-26 · Page 4 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC centrifugal fanforward curved, dual inletwith housing (without flange)
D2E133-AM47-94
Charts: Air flow 60 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]700650600550500450400350300250200150100500
qv[cfm]400350300250200150100500
]aP[sf p
460
440
420
400
380
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
pfs
_E[IN
H2O
]
1,851,81,751,71,651,61,551,51,451,41,351,31,251,21,151,11,0510,950,90,850,80,750,70,650,60,550,50,450,40,350,30,250,20,150,10,05]a
P[sf p
1
2
3
4
Measurement: LU-105265
Air performance measured as per ISO 5801Installation category A. For detailedinformation on the measuring set-up, pleasecontact ebm-papst. Suction-side noiselevels: LwA measured as per ISO 13347 /LpA measured with 1m distance to fan axis.The values given are valid under themeasuring conditions mentioned above andmay vary according to the actual installationsituation. With any deviation from thestandard set-up, the specific values have tobe checked and reviewed with the unitinstalled.
Measured values
1234
UV230230230230
fHz60606060
nmin-1
1800231026852945
Pe
W200181170159
IA0.880.780.740.70
qvm3/h565425300180
pfs
Pa100200300375
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase
Item no. 10430-5-9980 · Revision 66668 · Release 2010-08-26 · Page 5 / 5