GV3 Series v8.03 to v8.05 Control Panels en Quick Reference Guide
Transcript
Page 1: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05Control Panels

en Quick Reference Guide

Page 2: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067
Page 3: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Table of Contents | en 3

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

Table of Contents

1 GV3 Control Panel Connections (D9412GV3 Shown) 5

2 Upgrade GV3 Hardware and Programming 72.1 Receive Existing Control Panel Programming 72.1.1 Update the D5200 Programmer 72.1.2 Receive Existing Control Panel Programming with a D5200 Programmer 72.1.3 Receive Existing Control Panel Programming with RPS 72.2 Upgrade Hardware to a GV3 Series Control Panel 82.2.1 Prepare to Remove Existing Hardware 82.2.2 Remove the Existing Control Panel 82.2.3 Install the GV3 Control Panel In the Enclosure 82.2.4 Replace the Terminal Strips 92.3 Upgrade Programming to a GV3 Control Panel Programming 92.3.1 Upgrade a GV2 Series, G Series, or Non-G Series Control Panel to a GV3 Using a D5200 Series

Programmer92.3.2 Upgrade a Control Panel to a GV3 Using Remote Programming Software (RPS) 5.12 or Higher 9

3 Programming the Control Panel 113.1 RPS Programming over a Network Using the DX4020 Ethernet Network Interface Module 113.2 RPS Programming over a Network Using the ITS-DX4020-G GPRS/GSM Communicator 113.3 RPS Programming Using the DX4010V2 RS-232/USB Serial Interface Module 11

4 Programming to Set Up Central Station Reporting 124.1 Basic Telephone 124.2 Basic Internet Protocol (IP) 124.3 Account Number 12

5 Programming the Control Panel for Common Reporting Options 135.1 Set Up Daily Test Report Using a D5200 or RPS 135.2 Set Up Open and Close Reports Using a D5200 or RPS 135.2.1 Area Wide Parameters 135.2.2 Set Authority Level 13

6 Setting Up Points and Outputs 146.1 Using the Relay Option Within Point Assignments 146.2 Point Index (Default Values) 14

7 Add System Users Locally With a Keypad 177.1 Add Users (CMD 56) Using a Keypad 177.2 Add Card (CMD 56) for Access Control Only Using a Keypad 17

8 Turning the System ON or OFF and Keypad Commands 188.1 Arming and Disarming the System 188.1.1 Master Arming 18

Page 4: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

4 en | Table of Contents GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

8.1.2 Disarming 188.1.3 Set Duress +1 Using a D5200 or RPS 188.2 Basic and Advanced Commands 188.3 SIA CP-01 False Alarm Prevention Options 19

9 Setting DIP Switches 209.1 D9127 U/T POPIT Dip Switch Key 209.2 D9210B Switch Settings 209.3 D720, D1255, D1260 Dip Switch Settings 209.4 D9131A Dip Switch Settings 209.5 D8129 OctoRelay Dip Switch Settings 209.6 D8128C OctoPOPIT Dip Switch Settings 209.7 D8128D OctoPOPIT Dip Switch Settings 20

10 Reporting Format Definitions 21

11 Frequently Asked Questions 25

Page 5: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 GV3 Control Panel Connections (D9412GV3 Shown) | en 5

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

1 GV3 Control Panel Connections (D9412GV3 Shown)

Page 6: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

6 en | GV3 Control Panel Connections (D9412GV3 Shown) GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

Page 7: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Upgrade GV3 Hardware and Programming | en 7

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

2 Upgrade GV3 Hardware and Programming

2.1 Receive Existing Control Panel Programming

2.1.1 Update the D5200 ProgrammerIf you use the D5200 programmer to program the control panel, you must have the current GV2 handlers for all upgrades to GV3. If you have not previously updated your D5200 programmer handlers, download all current GV2 handlers to the D5200 from the handler server.The versions for the handlers on your programmer must be:

To download the handlers:1. Connect an RJ-11 telephone cord between the TELCO port on the D5200 programmer

and an outside telephone jack that accepts pulse dialing.2. Turn on the D5200 programmer and enter the password.3. Use the down arrow key to scroll to UPDATE and then press the [ENTER GROUP] key.4. Type the name of the handler you wish to update (for example, GV2MAIN), in the

HandName field.5. Press [ENTER] to scroll to Phone.6. Enter the telephone number for downloading handlers, 18006574584.

7. Press [ENTER] to scroll to Mode.8. Press the space bar until you see TELCO->A (or TELCO->B if the B card is present in the

D5200 programmer).9. Press [ENTER] to begin the handler download.

2.1.2 Receive Existing Control Panel Programming with a D5200 Programmer

1. Check the programmer memory for available space (> 40 kb free space is recommended).2. Receive a copy of the a handler from the old control panel and save it to your D5200

Programmer.3. If the control panel is a G or Non-G Series control panel, you must manually record the

9000MAIN and the RADXAUX1 programming. You must then add the information using the new GV2MAIN and GV2AUX handlers into the D5200 Programmer before you can send the program to the GV3 panel.

2.1.3 Receive Existing Control Panel Programming with RPS1. In RPS, double-click on the control panel name.2. Click Connect. Once connected, the Panel Sync window opens.3. Select the Recieve Panel Data option button and click OK.

- GV2MAIN v1.04 or later - RADXUSR1 v1.06 or later - RADXUSR2 v1.05 or later- RADXPNTS v1.08 or later - RADXSKED v1.04 or later - RADXAXS v1.06 or later- GV2AUX v1.04 or later

NOTICE! If the phone line requires you to first dial 9 to reach an outside line, include the 9 in the phone number you typed in Step 6 (i.e., type 918006574584).

NOTICE! GV3 control panels require updated GV2MAIN and GV2AUX handlers. Refer to Section 2.1.1 Update the D5200 Programmer, page 7 for instructions to download the latest handlers to your programmer.

Page 8: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

8 en | Upgrade GV3 Hardware and Programming GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

2.2 Upgrade Hardware to a GV3 Series Control Panel

2.2.1 Prepare to Remove Existing Hardware1. Power down the existing control panel by disconnecting the battery and the AC power.2. Remove the four removable terminal strips by tilting the strip up and outward.

Do not remove the wiring from the terminal strip.

2.2.2 Remove the Existing Control Panel1. Remove the lock down tab screw.2. Lift up on the control panel to free it from the enclosure mounting hooks, and remove the

control panel from the enclosure it.

2.2.3 Install the GV3 Control Panel In the Enclosure1. Place the GV3 Control Panel in the enclosure using the mounting skirt hook holes on the

back of the control panel and the mounting skirt hooks on the enclosure.2. Replace the lock down tab screw.

1 - Removable terminal strips

1 - Lock down tab

1 - Mounting skirt hook holes 2 - Mounting skirt hooks 3 - Lock down tab

Page 9: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Upgrade GV3 Hardware and Programming | en 9

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

2.2.4 Replace the Terminal Strips1. Replace the four removable terminal strips by pushing them straight down until they snap

into position.

2. Connect the battery and AC power.

2.3 Upgrade Programming to a GV3 Control Panel Programming

2.3.1 Upgrade a GV2 Series, G Series, or Non-G Series Control Panel to a GV3 Using a D5200 Series Programmer1. Send a copy of each saved handler from the D5200 to the new control panel.2. Test the control panel for operation.3. Delete the saved control panel information from the D5200.

2.3.2 Upgrade a Control Panel to a GV3 Using Remote Programming Software (RPS) 5.12 or Higher1. In RPS, highlight the control panel name by selecting it.2. Click the View button on the Remote Programmer Toolbar.3. In the resulting Panel Data - View window, click the Edit button.4. In the resulting Panel Data - Edit window, select the new control panel type from the

Panel Type drop-down. (If the control panel is a G or Non-G Series control panel, you must upgrade to GV2 first, and then repeat each of these steps to choose the GV3 control panel.) Click OK to close the window.

5. Click Save in the Panel View window to save the changes and close the Panel View window.

6. Click Connect. Once connected, the Panel Sync window opens.7. Select the Send ALL RPS Data to Panel option button and click OK.8. Once the sync completes, click Disconnect to disconnect from the control panel.9. Exit RPS.

NOTICE! If the control panel was previously mounted using the screw hole configuration, the you must re-mount the new control panel. The GV3 control panel mounting screw hole locations do not align with the locations for older control panels.

NOTICE! You must upgrade G Series and Non-G Series control panels to GV2 programming prior to upgrading to GV3 programming.

Page 10: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

10 en | Upgrade GV3 Hardware and Programming GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

10. Test the control panel for operation.

Page 11: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Programming the Control Panel | en 11

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

3 Programming the Control PanelYou can program the control panel with RPS using either a network connection or serial connection.

3.1 RPS Programming over a Network Using the DX4020 Ethernet Network Interface ModuleFor additional information, refer to IP Address Programming in the Conettix DX4020 Network Interface Module Installation Guide (P/N: F01U045288).

3.2 RPS Programming over a Network Using the ITS-DX4020-G GPRS/GSM CommunicatorFor additional information, refer to the Conettix ITS-DX4020-G Installation Guide (P/N: F01U163066).

3.3 RPS Programming Using the DX4010V2 RS-232/USB Serial Interface Module For additional information, refer to the DX4020 RS-232/USB Serial Interface Module Installation Instructions (P/N: F01U083036).

Page 12: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

12 en | Programming to Set Up Central Station Reporting GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

4 Programming to Set Up Central Station Reporting

4.1 Basic Telephone1. Go to PANEL WIDE PARAMETERS (GV2MAIN)→Phone (Phone and Phone Parameters

in RPS).2. Enter the primary telephone number in the Phone 1 field.3. If a secondary telephone number is required, enter it in the Phone 2 field.4. Go to Panel Wide Parameters→Routing→Route Group 1.5. Enter 1 in the Primary field.6. If a secondary telephone is required, enter 2 in the Secondary (Backup in RPS) field.

4.2 Basic Internet Protocol (IP)1. Go to PANEL WIDE PARAMETERS (GV2MAIN)→Routing→Route Group 1 Primary.2. Enter 1.3. Go to Enhanced Routing→Route Group 1 Primary SDI (88 or 92).4. Select YES.5. Go to GV2AUX→Enhanced Communications.6. Select or enter the following values:

4.3 Account NumberIn RPS, go to AREA WIDE PARAMETERS (GV2MAIN) and enter the account number (up to 10 digits) in the Account Number parameter. For a D5200 Programmer, receive a copy of GV2MAIN and then go to AREA WIDE PARAMETERS→Area Parameters. Enter the 4 digit account number in Acct#Digit 7&8 and Acct# Digit 9&10, press Send-Load to send changes to panel.

NOTICE! Enhanced Communications settings usually follow the recommendations of Central Stations staff.If using an ITS-DX4020-G for communication, refer to the ITS-DX4020-G Installation and Operation Guide (P/N: F01U163066).

Parameter ValueEnable Enhanced Communication YESPath 1 IP Address IP address of Central Station receiverPath 1 Port Number Port Number of Central Station receiver

Path 1 Poll Rate (seconds)1 Poll rate recommended by Central Station

Path 1 ACK Wait Time 13 sec (default setting)Path 1 Retry Count 5 (default Setting)1 If the control panel is programmed to send a heartbeat poll to the central station, a rate of 75 sec

maintains the virtual link in most network configurations.

NOTICE! Area 1 is the only area turned on by default.

Page 13: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Programming the Control Panel for Common Reporting Options | en 13

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

5 Programming the Control Panel for Common Reporting Options

5.1 Set Up Daily Test Report Using a D5200 or RPS1. Go to RADXSKED→Schedules→Skeds.2. Enter Function Code 9 (Test Report) in an unused Sked.3. Select NO for the Deferred parameter to send test reports regardless of other test

reports sending between scheduled test reports.4. Select NO for the Hourly parameter to send test reports only when the sked executes and

not every hour.5. Enter the time at which you wish the schedule to send the report.6. Leave the Date parameter disabled so that the sked executes by days of the week instead

of only on a selected date.7. Select YES for each day of the week.8. Select NO for:

– Except On Holiday– Holidays 1 - 4

5.2 Set Up Open and Close Reports Using a D5200 or RPS

5.2.1 Area Wide ParametersTo report each area independently:– Go to AREA WIDE PARAMETERS (GV2MAIN)→Open/Close Options→Acct O/C on the

D5200. Go to AREA WIDE PARAMETERS (GV2MAIN)→Area/Bell,Open/Close Options→Acct Open/Close in RPS. Select NO (default).

– Go to Area O/C on the D5200. Go to Area Open/Close in RPS). Select YES (default). To report by account (Close signal is sent when the last area in an account is armed; Open signal is sent when the first area is disarmed):– Go to AREA WIDE PARAMETERS (GV2MAIN)→Open/Close Options→Acct O/C on the

D5200. Go to AREA WIDE PARAMETERS (GV2MAIN)→Area/Bell,Open/Close Options→Acct Open/Close in RPS. Select YES.

– Go to Area O/C on the D5200. Go to Area Open/Close in RPS. Select NO.

5.2.2 Set Authority Level1. Go to USER INTERFACE (GV2MAIN)→Authority Levels.2. Go to the Authority Level to be used by users sending Open and Close reports.3. Select E (enabled) for Area O/C (Area Open/Close in RPS).4. Select E for Restricted O/C (Restricted Open/Close in RPS).5. Select E for Perimeter O/C (Perimeter Open/Close in RPS).

NOTICE! If you want Perimeter Open and Close, select Perimeter O/C = YES.

Page 14: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

14 en | Setting Up Points and Outputs GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

6 Setting Up Points and Outputs

6.1 Using the Relay Option Within Point AssignmentsRelay Programming allows any one point or several points to latch a single relay through software when the selected point generates an alarm. Relays are number 1 through 8 and are programmed by entering the number of the relay (1 - 8) in the Relay column in Point Assignments. This relay latches on a generated alarm and resets after acknowledging and then clearing the alarm from memory.

Table 6.1 Actual Relays Latched by Control Panel Type

Table 6.2 D8129 Switch Settings for All Control Panel Types

6.2 Point Index (Default Values)

RelayD8129 Actual Relay Number

D7412GV3/D7212GV31 D9412GV32

1 9 732 10 743 11 754 12 765 13 776 14 787 15 798 16 801 For the D7412GV3 and D7212GV3, connect to Terminal 28 for data (Zonex 1 Out).2 For the D9412GV3, connect to Terminal 26 for data (Zonex 2 Out).

Switch Number Setting1 ON2 OFF3 ON4 ON

NOTICE! Programmers must be aware of the following considerations:– Do not use relays designated within Point Assignments for multiple functions. For

example, Relays 73 through 80 on the D9412GV3 should not be used for relay-follow-point or area-wide or panel-wide relays.

– Relays should not be selected to follow points programmed as Invisible Points.

Pt Index Number

Description Pt Index Number

Description

1 24-Hour Instant Audible Alarm on Open or Short

17 D279 (Non-Priority)

2 Invisible/Silent Hold Up on Short 18 D279 (Priority)3 Fire Pull Station Alarm on Short 19 Easikey Input4 Smoke Detector with Reset Alarm on Short 20 POPIT Motion Sensor Interior5 Smoke Detector with Verification Reset and

Alarm on Short21 POPIT Motion Sensor Perimeter

6 Bell Supervision Trouble on Open/Short 22 Fire Supervisory on Open, Trouble on Short7 Perimeter Instant Alarm on Open or Short,

Watch Point when Disarmed23 Non-Fire Supervisory on Open, Trouble on

Short8 Perimeter Delay on Short, Instant Alarm on

Short, Watch Point when Disarmed24 Local, No Visual or Audible Display on Any Fault

Armed or Disarmed with Relay Output

Page 15: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Setting Up Points and Outputs | en 15

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

Table 6.3 Point Index Numbers and Descriptions

To make a custom Point Index, refer to (Table 6.4 and Table 6.5).

Table 6.4 Point Type Selections

To make a custom point index, use Table 6.4 on Page 15 and Table 6.5 on Page 16. For example, to create an Interior Follower point with a delay on Open and Trouble on Short, use Point Type 3 and Point Response 5.

9 Perimeter Instant Alarm on Open or Short, Local while Disarmed

25 Perimeter Delay on Open, Alarm on Short

10 Interior Instant Alarm on Open or Short 26 24-Hour Instant Audible Alarm on Open or Short

11 Interior Delay on Short, Alarm on Open 27 24-Hour Instant Audible Alarm on Open or Short

12 Interior Instant Alarm on Open or Short, Local while Disarmed

28 24-Hour Instant Audible Alarm on Open or Short

13 Interior Follower Delay on Short, Alarm on Open

29 24-Hour Instant Audible Alarm on Open or Short

14 Maintained Keyswitch 30 24-Hour Instant Audible Alarm on Open or Short

15 Momentary Keyswitch 31 24-Hour Instant Audible Alarm on Open or Short

16 Open/Close on Fault

Pt Index Number

Description Pt Index Number

Description

NOTICE! The default indexes are not always the best selection.If you experience unwanted trouble conditions, refer to Table 6.5 on Page 16 and make any necessary adjustments.Bosch Commercial Wireless points produce a Short when faulted and an Open for a tamper.

Pt Type Description Pt Type Description0 24-Hour 6 O/C/ Port1 Perimeter 7 D279 (O/C Non-Priority)2 Interior 8 D279 (Priority)3 Interior Follower 9 Easikey4 Keyswitch 11 AUX AC Supervision5 Keyswitch Memory

NOTICE! The selections in Table 6.5 indicate:– D = Delayed Response– I = Instant Alarm– S = Supervisory– T = Trouble– Blank = No Response

Page 16: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

16 en | Setting Up Points and Outputs GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

Table 6.5 Point Response Selections

Point Response Selections*

0 1 2 3 4 5 6 7 8 9 A B C D E F

Armed Open I I I I D D I I D I I I I I TShort I I I I I I D D D I I I I I I

Disarmed Open T T T I I T I TShort T T T I T I I

24-Hour Open I T I T I T S T S S N/AShort I I T T I T T S S S

Page 17: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Add System Users Locally With a Keypad | en 17

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

7 Add System Users Locally With a Keypad

7.1 Add Users (CMD 56) Using a Keypad

Table 7.1 Adding Users with Command 56

7.2 Add Card (CMD 56) for Access Control Only Using a Keypad

Table 7.2 Adding Cards with Command 56

Step Operator Entry Keypad Response1 Enter Command 56 Enter Passcode2 Enter passcode and press [ENT]. Enter User #3 Enter the user number and press [ENT]. USER # (default name text)4 Enter Change Passcode?5 Enter Enter New Code6 Enter the new user’s passcode. Enter New Again7 Re-enter the new passcode. Code Changed

Step Operator Entry Keypad Response1 Command 56 Enter Passcode2 Enter passcode and press [ENT] Enter User #3 Enter the user number and press [ENT] USER# (default name text)4 Enter Change Passcode?5 Next Add Card?6 Enter Present Card7 Present the credential to the reader. Card Added

NOTICE! To use Add Card (CMD 56), you must program the Assign Door prompt within Command Center Assignments with the D9210B door controller number. If you do not program the Assign Door prompt, the keypad reads 9210 NOT READY.

Page 18: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

18 en | Turning the System ON or OFF and Keypad Commands GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

8 Turning the System ON or OFF and Keypad Commands

8.1 Arming and Disarming the System

8.1.1 Master ArmingEnter the passcode and [ENTER] to arm all areas where the user has authority and are areas within the scope of the keypad.

8.1.2 DisarmingEnter the passcode and [ENTER] to disarm all areas where the user has authority and are areas within the scope of the keypad.

8.1.3 Set Duress +1 Using a D5200 or RPS1. Go to PANEL WIDE PARAMETERS (GV2MAIN)→Miscellaneous→Duress Type. Select 1.2. Go to AREA WIDE PARAMETERS (GV2MAIN)→Area Parameters→Duress Enable.

Select YES.3. Go to User Interface→Authority Levels. In the authority levels to be used, select E for

the Send Duress parameter.

8.2 Basic and Advanced Commands

Table 8.1 Basic and Advanced Commands

99 Enter CommandsFor each of the following commands, press [9] [9] [ENTER]. Press [NEXT] to view each command.– 1 - View Log– 2 - Print Log– 3 - Display Revision– 4 - Service Walk– 5 - Default Text

Basic Commands Advanced CommandsCMD 1 (Master Arm) [Master Arms only the area assigned to the Keypad]

CMD 0 (Bypass a Point)

CMD 11 (Master Arm Instant) CMD 00 (Unbypass a Point)CMD 3 (Perimeter Delay) CMD 41 (Test Report)CMD 4 (Silence Trouble Sounder) CMD 42 (Status Report)CMD 4, 0 (View memory) CMD 43 (Remote Program)CMD 4, 4 (Walk Test) CMD 45 (Change Time/Date)CMD 4, 7 (Reset Sensors) CMD 49 (Change Display)CMD 6 (Watch Mode) CMD 50 (Move to Area)CMD 7 (Special Alert) CMD 51 (Extend Closing)CMD 8 (Perimeter Partial) CMD 52 (Change Sked)CMD 9 (Special Alert) CMD 53 (Delete Passcode)CMD 2 Perimeter Instant CMD 54 (Change Relay)

CMD 55 (Change Passcode)CMD 56 (Add Passcode)CMD 58 (Fire Test)PRINT LOG (99 [ENTER])VIEW LOG (99 [ENTER])

Page 19: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Turning the System ON or OFF and Keypad Commands | en 19

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

8.3 SIA CP-01 False Alarm Prevention Options

– Master Arm-No Exit=YES: This setting provides for a Perimeter Delay point to be faulted when master arming each area, or the arming state defaults to Perimeter Delayed.

– Exit Delay Warning=YES: When this parameter is set to YES, the alarm bell pulses on and off every two seconds for the remaining 10 sec of Exit Delay.

– Entry Delay Warning=YES: When this parameter is set to YES, the alarm bell pulses on and off every two seconds for the remaining 10 sec of Entry Delay.

NOTICE! Some programming parameters are preset for compliance with SIA standard CP-01 (false alarm prevention). These settings are in AREA WIDE PARAMETERS (GV2MAIN)→Area Parameters. They affect control panel operation as described below.

Page 20: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

20 en | Setting DIP Switches GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

9 Setting DIP Switches

9.1 D9127 U/T POPIT Dip Switch KeyPOPIT addresses are binary. Refer to Table 9.1:

Table 9.1 POPIT Dip Switch Keys

To calculate the switch settings for POPITS, you must determine the value to use in the calculation. For addresses 9 through 127, subtract 9. For addresses 129 through 247, subtract 129. Use the following procedure with address 48 as the example, substituting the actual values in your calculation.1. Subtract 9 from 48. The result is 39.2. Set the switches that add up to 39 to the OFF positions (32 + 4 + 2 + 1 = 39).

SW 1 OFF = 32

SW 4 OFF = 4

SW 5 OFF = 2

SW 6 OFF = 1

9.2 D9210B Switch SettingsFor additional information, refer to the Access Control Interface Module D9210B Operation and Installation Guide (P/N: 32206).

9.3 D720, D1255, D1260 Dip Switch SettingsFor additional information, refer to:– D720 Series Keypads Installation Instructions (P/N: 7406918000)– D1255/D1255B Keypads Installation Instructions (P/N: 7406819000)or– D1260/D1260B Keypads Installation Guide (P/N: 48101)

9.4 D9131A Dip Switch SettingsFor additional information, refer to the Parallel Printer Interface D9131A Installation Guide (P/N: F01U135506).

9.5 D8129 OctoRelay Dip Switch SettingsFor additional information, refer to the D8129 OctoRelay Module Operating and Installation Guide (P/N: F01U036302).

9.6 D8128C OctoPOPIT Dip Switch SettingsFor additional information, refer to the D8128C OctoPOPOIT Module Operating Instructions (P/N: 7407710000).

9.7 D8128D OctoPOPIT Dip Switch SettingsFor additional information, refer to the D8128D OctoPOPOIT Module Installation Guide (P/N: F01U070537).

Switch Number 0 1 2 3 4 5 6Binary Value 64 32 16 8 4 2 1

Page 21: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Reporting Format Definitions | en 21

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

10 Reporting Format DefinitionsModem IIIa2 Event Modem IIIa2 Code

D6500 ModeModem IIIa2 CodeBosch SIA Mode

Contact ID Event Contact ID Code

A point supervisory condition occurred

Jsppp NriaBSppp 24 hour Non-Burglary 1 150 00 000

A valid local access occurred

RsF01 NLS Successful Download/Access 1 412 00 000

A valid remote access callback occurred

RsssF NphhhRS Successful Download/Access 1 412 00 000

A valid remote access occurred

RsssF NRS Successful Download/Access 1 412 00 000

AC Fail – mains power supply

Pssss NAT AC Loss 1 301 00 000

AC Restore – mains power supply

Rsss0 NAR AC Loss 3 301 00 000

Access Denied – Door Secured

ADsppp Nria/idiiiDZppp or Nria/idiii/ssxDZppp

Access Denied 1 421 aa uuu

Access Denied – Interlocked

ADsppp Nria/idiiiDWppp or Nria/idiii/ssxDWppp

Access Denied 1 421 aa uuu

Access Denied – No rights in area by card

ADsppp Nria/idiiiDVppp or Nria/idiii/ssxDVppp

Access Denied 1 421 aa uuu

Access Denied – Unknown ID

ADsppp NriaDDppp Access Denied 1 421 aa uuu

Access Granted AGsppp Nria/idiiiDGppp or Nria/idiii/ssxDGppp

Access Report by User 1 422 aa uuu

Alarm Asppp NriaBAppp Burglary 1 130 aa pppAlarm Cross Point Asppp NriaBMppp Burglary 1 130 aa pppAlarm Exit Error Asppp Nria/idiiiEAppp Entry/Exit 1 134 aa pppAlarm with Recent Closing Asppp Nria/CRppp Entry/Exit 1 459 aa uuuAll SDI devices are missing, power is shorted

TsssD NpidddET Expansion Module Failure 1 333 00 000

All SDI devices are restored, power is normal

RsssD NpidddER Expansion Module Failure 3 333 00 000

An individual SDI device is missing.

TsssD NpidddEM Expansion Module Failure 1 333 00 000

An individual SDI device is restored.

RsssD NpidddEN Expansion Module Failure 3 333 00 000

An invalid remote access callback occurred

TsssF NphhhRU Unsuccessful Access 1 413 00 000

An invalid remote access occurred

TsssF NRU Unsuccessful Access 1 413 00 000

Armed perimeter delay Csiii Nria/idiiiNL Armed STAY 3 441 aa uuuArmed perimeter instant Csiii Nria/idiiiNL Armed STAY 3 441 aa uuuBypass by Remote Nsppp NriaUBppp Zone/Sensor Bypass 1 570 aa pppBypass by SDI device Nsppp Nria/pidddUBppp Zone/Sensor Bypass 1 570 aa pppBypass by Sked Nsppp Nria/aikkkUBppp Zone/Sensor Bypass 1 570 aa pppBypass by User Nsppp Nria/idiiiUBppp Zone/Sensor Bypass 1 570 aa pppBypass Point Nsppp NriaUBppp Zone/Sensor Bypass 1 570 aa ppp

Page 22: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

22 en | Reporting Format Definitions GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

Checksum failure on configuration memory

TsD15 NYF RAM Checksum Bad 1 303 00 000

Closing by Area Csiii Nria/idiiiCL O/C by User 3 401 aa uuuClosing Early by Area Csiii Nria/idiiiCK Early O/C 3 451 aa uuuClosing Late by Area Csiii Nria/idiiiCJ Late O/C 3 452 aa uuuCommunication failure by route group

TsB01 NrggYC Failure to communicate event 1 354 00 000

Communication failure by route group restored

NsB01 NrggYK Failure to communicate event 3 354 00 000

Communication trouble by network

TsB01 Nrgg/pidddYS Communication Trouble 1 350 00 000

Communication trouble by network restored

NsB01 Nrgg/pidddYK CommunicationTrouble 3 350 00 000

Communication trouble by phone

TsB01 NphhhYS Communication Trouble 1 350 00 000

Communication trouble by phone restored

NsB01 NphhhYK Communication Trouble 3 350 00 000

Control panel battery low Tsss9 NYT Low System Battery 1 302 00 000Control panel battery missing

Tsss9 NYM Battery Missing/Dead 1 311 00 000

Control panel battery restored to normal

Rsss9 NYR Low System Battery 3 302 00 000

Create Status Report Sssss NYY Status Report to Follow 1 605 00 000Date changed – no user identified

NsD07 NJD Time/Date Reset 1 625 00 000

Dated changed by user NsD07 NidiiiJD Time/Date Reset 1 625 00 uuuDoor Closed, Restoral Rsppp NriaDHppp Access Door propped open 1 426 aa pppDoor Left Open Alarm Asppp NriaDLppp Access Door propped open 1 426 aa pppDoor Left Open Trouble Tsppp NriaDMppp Access Door propped open 1 426 aa pppDuress Dsiii Nria/idiiiHA Duress 1 121 aa uuuEvent Log Overflow AsD01 NJO Event Log Overflow 1 624 00 000Event Log Threshold has been reached

TsD01 NJL Event Log 90% Full 1 623 00 000

Extend Close Time TsD26 Nria/idiii/tihhmmCE

Auto-arm Time Extended 1 464 aa uuu

Extra Point Tsppp NriaXEppp Maintenance Alert 1 393 aa pppFail To Close by Area TsssE NriaCI Failed to Close 1 454 aa 000Fail To Open by Area TsssE NriaOI Failed to Open 1 453 aa 000Fire Alarm Fsppp NriaFAppp Fire 1 110 aa pppFire Cancel \siii Nria/idiiiFC Cancel 1 406 aa pppFire Missing Msppp NriaFYppp Fire Trouble 1 373 aa pppFire Restoral from Alarm Hssppp NriaFHppp Fire 3 110 aa pppFire Restoral from Trouble Hsppp NriaFJppp Fire Trouble 3 373 aa pppFire Supervision Esppp NriaFSppp Fire Supervisory 1 200 aa pppFire Supervision from Restore

Esppp NriaFVppp Fire Supervisory 3 200 aa ppp

Fire Trouble Gssppp NriaFTppp Fire Trouble 1 373 aa pppFire Walk Test End RsssF Nria/idiiiFK Fire Test 3 604 aa uuuFire Walk Test Start TsssF Nria/idiiiFI Fire Test 1 604 aa uuuForce Armed Perimeter Delay

Csiii Nria/idiiiNF Partial Arm 3 456 aa uuu

Modem IIIa2 Event Modem IIIa2 CodeD6500 Mode

Modem IIIa2 CodeBosch SIA Mode

Contact ID Event Contact ID Code

Page 23: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Reporting Format Definitions | en 23

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

Force Armed Perimeter Instant

Csiii Nria/idiiiNF Partial Arm 3 456 aa uuu

Forced Close Early by Area

Csiii Nria/idiiiCF Early O/C 3 451 aa uuu

Forced Close Late by Area Csiii Nria/idiiiCF Late O/C 3 452 aa uuuForced Closing by Area Csiii Nria/idiiiCF O/C by user 3 401 aa uuuForced Point Tsppp NriaXWppp Zone/Sensor Bypass 1 570 aa pppInvalid local access detected

TsF01 NLU Unsuccessful access 1 413 00 000

Low battery on a wireless point

Tsppp NriaXTppp RF Low Battery 1 384 aa ppp

Low battery restore on a wireless point

Rsppp NriaXRppp RF Low Battery 3 384 aa ppp

Missing Alarm Msppp NriaUZppp General Alarm 1 140 aa pppMissing Fire Supervision GMsppp NriaFZppp Fire Trouble 1 200 aa pppMissing Supervision MTsppp NriaBZppp Loss of Supervision - RPM 1 382 aa pppMissing Trouble Vsppp NriaUYppp Loss of Supervision - RPM 1 382 aa pppNon- Fire Cancel Alarm \siii Nria/idiiiBC Cancel 1 406 aa pppNormal start-up of the control panel

NsD14 NRR System Reset 1 305 00 000

Opening by Area Osiii Nria/idiiiOP O/C by user 1 401 aa uuuOpening Early by Area Osiii Nria/idiiiOK Early O/C 1 451 aa uuuOpening Late by Area Osiii Nria/idiiiOJ Late O/C 1 452 aa uuuParameters changed by RPS

NsD02 NYG Panel Programming Changed 1 306 00 000

Phone Line Missing (1 or 2)

TsssB NLT1 or NLT2 Telco 1 Fault 1 351 00 000

Phone Line Restored (1 or 2)

RsssB NLR1 or NLR2 Telco 1 Fault 3 3515 00 000

Point Bus Fail TsssD NET Protection Loop 1 370 00 000Point Bus Restoral, power normal or bus not missing

RsssD NER Protection Loop 3 370 00 000

RAM Fail with RPS TsF02 NRA Unsuccessful access 1 413 00 000Relay Reset by Programmer

NsD22 NpidddROrrr Sounder/Relay 3 320 00 000

Relay Reset by Remote NsD24 NROrrr Sounder/Relay 3 320 00 000Relay Reset by Sked NsD20 NaikkkROrrr Sounder/Relay 3 320 00 000Relay Reset by User NsD18 NidiiiROrrr Sounder/Relay 3 320 00 000Relay Set by Programmer NsD21 NpidddRCrrr Sounder/Relay 1 320 00 000Relay Set by Remote NsD23 NRCrrr Sounder/Relay 1 320 00 000Relay Set by Sked NsD19 NaikkkRCrrr Sounder/Relay 1 320 00 000Relay Set by User NsD28 NidiiiRCrrr Sounder/Relay 1 320 00 000Remote Reset – System was reset by RPS

NsD11 NRN System Reset 1 305 00 000

Restoral Rsppp NriaBRppp Sensor Trouble 3 380 aa pppRestoral from Alarm Rsppp NriaBHppp Burglary 3 130 aa pppRestoral from Ground Fault

Rsppp NriaBRppp Ground Fault 3 310 aa ppp

ROM Checksum Fail (Not Used)

AsD12 NYX ROM Checksum bad 1 304 00 000

Sensor Reset NsD27 Nria/idiiiXIrrr Sounder/Relay 3 320 00 000Service Walk Test End RsssF NidiiiTE Service On/Off Premises 3 466 aa uuu

Modem IIIa2 Event Modem IIIa2 CodeD6500 Mode

Modem IIIa2 CodeBosch SIA Mode

Contact ID Event Contact ID Code

Page 24: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

24 en | Reporting Format Definitions GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

Table 10.1 Reporting Format Definitions

Service Walk Test Start TsssF Nria/idiiiTS Service On/Off Premises 1 466 aa uuuSked Changed – No User Identified

NsD06 NaikkkJS Schedule Change 1 630 00 000

Sked Changed by User NsD06 Nidiii/aikkkJS Schedule Change 1 630 00 000Sked Changed Remotely NsD06 Nid255/aikkkJS Schedule Change 1 630 00 000Swinger Bypass Nsppp NriaUBppp Swinger Bypass 1 575 aa pppTest Report – System Normal, Expanded Status

RsssE NRP & see D6600 CIM for Status Items

Periodic Test Report 1 602 00 000

Test Report – System Normal, Non-expanded Status

RsssE NRP Periodic Test Report 1 602 00 000

Test Report – System Off-normal, Expanded Status

RsssE NRY & see D6600 CIM for Status Items

Periodic Test – System Trouble Present

1 608 00 000

Test Report – System Off-normal, Non-expanded Status

RsssE NRY Periodic Test – System Trouble Present

1 608 00 000

Time Changed – No User Identified

NsD07 NJT Time/Date Reset 1 625 00 000

Time Changed by Receiver Sync

NsD07 Nid254JT Time/Date Reset 1 625 00 254

Time Changed by User NsD07 NidiiiJT Time/Date Reset 1 625 00 uuuTrouble Tsppp NriaBTppp Sensor Trouble 1 380 aa pppTrouble with Ground Fault Tsppp NriaBTppp Ground Fault 1 310 aa pppUnverified Event Ksppp NriaUGppp Cross-zone Trouble 1 378 aa pppUser Alarm 7 Usss7 Nria/idiiiUA Personal Emergency 1 101 aa uuuUser Alarm 9 UUsss9 Nria/idiiiPA Duress 1 121 aa uuuUser Passcode Tamper – Too Many Attempts

NsD03 NriaJA Wrong Code Entry 1 461 aa 000

Walk Test End RsssF Nria/idiiiTE Walk test mode 3 607 aa uuuWalk Test Start TsssF Nria/idiiiTS Walk test mode 1 607 aa uuuWatchdog Reset – SDI Device Reported identifies the Source

NsD09 NpidddYW System Reset 1 305 00 000

Modem IIIa2 Event Modem IIIa2 CodeD6500 Mode

Modem IIIa2 CodeBosch SIA Mode

Contact ID Event Contact ID Code

Page 25: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

GV3 Series v8.03 to v8.05 Frequently Asked Questions | en 25

Bosch Security Systems, Inc. Quick Reference Guide F01U266681 | 01 | 2012.03

11 Frequently Asked QuestionsWhat does it mean when my keypad reads "CALL FOR SERVICE"?That keypad is not receiving data from the control panel.

What does it mean when my keypad reads "SERVICE KEYPAD"?A supervised keypad has lost communications with the control panel.

How do I arm an area that is not assigned to my keypad?Add to the FUNCTION LIST a menu item with a function code of 1 and with CC ADDRESS 1-8 set to YES, and a menu item with a function code of 2 and with CC ADDRESS 1-8 set to Yes. Assign the function codes to the necessary command center. The new menu items allow your users to select the area they wish to arm or disarm.

How do I perform area-specific functions from a keypad?Use the MOVE TO AREA command (CMD 50) to move to an area within the keypad’s scope.

Can I default a lockcode without knowing the lockcode?No. You must send the unit to the Bosch Repair Center.

How do I upgrade the control panel version?Use the supplied firmware upgrade key to upgrade the firmware. Lift the control panel faceplate cover to access the port to insert the upgrade key and read the instructions located on the back of the faceplate.

How do I add an access card using the command center?Use the ADD USER command (CMD 56) to add an access card. Present the access card to the assigned door to add the card.

What does it mean when my keypad reads "9210 NOT READY"?No door is assigned to the command center. Check the ASSIGN DOOR parameter within COMMAND CENTER ASSIGNMENTS menu item, and then enter the D9210B address (1 - 8).

What are SDI addresses 33 to 40?They are D9210B addresses.

What are SKEDS 41 to 56?They are Open and Close windows.

How do I test a relay from the keypad?Use the RELAY CONTROL command (CMD 54) to toggle relays.

How do I toggle the on-board relays A, B, and C?Use the RELAY CONTROL command (CMD 54), and then the relay number: 253 for A; 254 for B; and 255 for C.

How many Amp Hours can the panel sustain?You can connect two (2) 18 Ah batteries for a total of 36 Ah. You can gain up to an additional 27 Ah with by connecting a D8132 module.

Is the control panel compatible with digital or VOIP phone lines?The control panel has been tested with only analogue lines. Use a DX4020 to transmit over Ethernet or a ITS-DX4020-G to transmit over cellular. You can use a C900V2 to convert analogue signals to Ethernet for transmission to a D6600 receiver.

How do I silence a trouble condition?Use the SILENCE TROUBLE SOUNDER command (CMD 4) to silence a trouble condition.

Page 26: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067

26 en | Frequently Asked Questions GV3 Series v8.03 to v8.05

F01U266681 | 01 | 2012.03 Quick Reference Guide Bosch Security Systems, Inc.

How do I clear alarm memory?Ensure all points are normal, and the enter your passcode and press [ESC], or press the [Clear] soft key.

How do I determine if I have a ground fault?On the control panel, measure voltage on terminal 9 (common) and terminal 10 (earth ground). Approximately 6.5 to 6.8 VDC is normal voltage and equals no ground fault. Disconnect wires until you see normal voltage to find your ground.

Can I add wireless capability to this control panel?Yes. Use the Bosch Commercial Wireless Kit (ISW-CWKIT-01) and the proper Bosch Commercial Wireless transmitters to fully integrate wireless on the control panel.

What type of cable do I use to connect my computer’s COM port to a serial-enhanced direct connection using the DX4010i?A null modem cable is required.

How can I determine which points are not ready when my keypad reads "NOT READY TO ARM"?Press the NEXT key to scroll through faulted points. If the VIEW POINT STATUS menu item is enabled, you can access it through the menu to determine the state of the faulted point.

What does it mean when my keypad reads "CHECK DEVICE"?A point is faulted. The point is one that is configured to display as a device in the POINT INDEX by marking YES for the DISPLAY AS DEVICE parameter.

I hear a trouble tone from my keypad but no point is shown as in trouble on the keypad. How do I resolve this?A point generates a trouble tone (buzz) when faulted if is configured to do so. To determine which points are configured to buzz, look in the POINT INDEX for points with a non-zero value for the BUZZ ON FAULT parameter.

How can I determine the meaning of an undefined signal received from central station?Press 99 [ENTER] on the keypad to reveal the VIEW LOG menu item. Locate the signal in the log by date and time.

Which reporting formats can the panel send?

Modem IIIa2 or Contact ID. BFSK was replaced with Contact ID for the GV3 control panel.

What is the default Installer Code?The code is 123.

What is the default User Code?The code is 123456.

What is the default RPS Passcode?The code is 999999.

Is the GV3 control panel keypad programmable?No. You must program the control panel using the D5200 Series Programmer or RPS version 5.12 or higher.

What is the phone number to update the D5200 Series Programmer?The number is 1-800-657-4584.

Where can I find free documentation and on-line support for this product?Go to www.boschsecurity.us.

Page 27: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067
Page 28: D9412GV3 Series Quick Installation Guide EnUS 9007201746701067