Date post: | 24-Oct-2014 |
Category: |
Documents |
Upload: | evaldo-grasso-nunes |
View: | 192 times |
Download: | 14 times |
SUBMERSIBLE AND SUBMERGED PUMPS
4
TECHNICAL CATALOGUE SECTIONS:
1 2 3 4 5 6
WET ROTOR CIRCULATORS AND IN-LINE PUMPS SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS CENTRIFUGAL PUMPS SUBMERSIBLE PUMPS SUBMERGED PUMPS BOOSTER SETS
CONTENTSNOVA - FEKA FEKA VS - FEKA VX DRENAG - FEKA - GRINDER PROTECTION AND CONTROL SYSTEMS INSTALLATION DIAGRAMS
SUBMERSIBLE PUMPS
page 3-54
DRAINAGE STATIONS
NOVABOX FEKALIFT FEKABOX FEKAFOSpage 55-78
DAB PUMPS reserve the right to make modifications without prior notice
1
2
DAB PUMPS reserve the right to make modifications without prior notice
SUBMERSIBLE PUMPSTABLE OF PERFORMANCE RANGES AND POSSIBLE APPLICATIONSNOVA FEKA 600 FEKA VS FEKA DRENAG DRENAG FEKA GRINDER FEKA NOVABOX FEKALIFT FEKABOX FEKABOX FEKABOX FEKAFOS FEKAFOS FEKAFOS VX 1000-1200 2500/3000 30/300 100 200 280 200 280 550 4000/6000
DNA connections
DN 28 DN 50 VARI DN 40 DN 110 DN110 DN110 DN 110 DN110 DN110
DNM connections
1 /4 G 1 /4 G 2 F
1
1
2 F 1 /2 G 2 G 2 G
1
2 G DN 150 1 /4 G DN 25 2 G 2 G
DN 65
1
2 G
2 G
2 G
2 G
Flow rate Q (m /h)
3
16
16
32
32
23
33
30
9
162
7,5
3,9
24
24
24
35
35
65
Head H (m)
10,2
7,4
14
14
17
21,5 15,5
26,5
40
6,9
6,9
9
9
9
9
26,5
26,5
Temperature t (C)
+50
+50
+50
+50
+50
+55
+55
+55
+55
+50
+60
+50
+50
+50
+50
+55
+55
Ground-water
Rain water
Clean waste water
Dirty waste water
Fountain water
River or lake water
Sandy water A Sewage containing, solids and long fibres
DAB PUMPS reserve the right to make modifications without prior notice
3
PERFORMANCE RANGE
SELECTION TABLE
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 Kg/m3. Curve tolerance according to ISO 9906.
0
20 20
40 40
60 60
80
100 80
120 100
140 120
P kPa
H m
0
Q US gpm Q IMP gpm H ft90
250
25
80
70 200 20
GRINDER 1400/1800150 15
60
50
DRENAG 1400/180040 100 10
DRENAG 1000 - 1200 FEKA 1400/1800 NOVA 600 FEKA VS-VX
30
50
5
FEKA 600 NOVA 300 NOVA 180 NOVA 2006 1 100 2 9 3 200 12 4 15 18 5 300 21 6 400 24 7 27 8 500 30 9 33 36 Q m3/h 10 Q l/s
20
10
0
0
0
0 0 0
3
600 Q l/min
0 0
100 100
200 200
300 300
400
500 400
600 500
700 600
800 700
1000 800 1000
1500 1500
Q US gpm Q IMP gpmH ft
P kPa400 360 320 280 240 200 160 120 80 40 0
H m40 36 32
120
10028 24 20 16 12 8 4 0 FEKA 2500.4T FEKA 3000.4T 0 0 20 500 40 10 1000 60 20 1500 80 100 30 2000 FEKA 2700.2T FEKA 2500.2T FEKA 3700.2T FEKA 3500.2T FEKA 6250.4T FEKA 4150.2T FEKA 4125.2T FEKA 4200.2T
80
60
40FEKA 3000.2T FEKA 4100.4T FEKA 4100.2T FEKA 4000.4T 120 140 40 2500 160 FEKA 6100.6T FEKA 6120.4T FEKA 6200.4T FEKA 6300.4T
20
FEKA 6075.6T 180 50 3000 4000 200 300 100 5000 6000 8000 400 500
0 Q m3/h Q l/s
Q l/min
4
DAB PUMPS reserve the right to make modifications without prior notice
PERFORMANCE RANGEP2 NOMINAL kW HP Q m3/h l/min
SELECTION TABLE
MODEL SINGLE-PHASE THREE-PHASE
0 0
1 16,6
2 33,3
3 50
4,5 75
5 83,3
6 7 7,5 100 116,6 125
9 10 12 150 166,6 200
15 250
18 300
24 400
30 500
36 600
NOVA 180 M-A * NOVA 180 M-NA * NOVA 200 M-NA * NOVA 300 M-A * NOVA 600 M-A * NOVA 600 M-NA * NOVA 600 T-NA * FEKA 600 M-A * FEKA 600 M-NA * FEKA 600 T-NA * FEKA VS-VX 550 M-A FEKA VS-VX 550 M-NA FEKA VS-VX 550 T-NA FEKA VS-VX 750 M-A FEKA VS-VX 750 M-NA FEKA VS-VX 750 T-NA FEKA VS-VX 1000 M-A FEKA VS-VX 1000 M-NA FEKA VS-VX 1000 T-NA FEKA VS-VX 1200 M-A FEKA VS-VX 1200 M-NA FEKA VS-VX 1200 T-NA DRENAG 1000 M-A/M-NA DRENAG 1000 T-NA DRENAG 1200 M-A/M-NA DRENAG 1200 T-NA DRENAG 1400 M DRENAG 1800 T FEKA 1400 M FEKA 1800 T GRINDER 1400 M GRINDER 1800 T
0,22 0,22 0,22 0,22 0,55 0,55 0,55 0,55 0,55 0,55 0,75 0,75 1,00 1,00 1,20 1,20 1 1,2 1,1 1,5 1,1 1,5 1,1 1,52
0,3 0,3 0,3 0,3 0,75 0,75 0,75 0,75 0,75 0,75 1 1 1,36 1,36 1,60 1,60 1,36 1,6 1,5 2 1,5 2 1,5 26,5
4,8 4,8 6,6 6,8 10,2 10,2 7,45 7,45 7,4 7,4 9,6 9,6 11,8 11,8 14 14 15,3 17 19,2 21,5 13,9 15,5 24,5 25,3
4,3 4,3 6,2 6,4 9,7 9,7 7,1 7,1
3,8 3,8 5,8 6 9,3 9,3 6,75 6,75
3 3 5,2 5,6 8,9 8,9 6,45 6,45 6,9 6,9 9,2 9,2 11,3 11,3 13,4 13,4 13,7 15,4
1,6 1,6 4,6 5,1 8,3 8,3 6,1 6,1 4,4 4,9 8,1 8,1 5,95 5,95 4 4,6 7,8 7,8 5,7 5,7 6,2 6,2 8,5 8,5 10,5 10,5 12,8 12,8 13,2 14,7 13 14,5 12,1 13,8 17 20 12 13,7 11,5 13,4 16,5 19,8 11,6 13,3 17,4 21,6 11,2 13 16,3 19,6 11,4 13,1 16,8 20,3 10,5 12,4 15,9 19 11 12,8 14,1 19,9 10 11,8 15,6 18,9 10,8 12 13 17 16 3,4 4,2 7,4 7,4 5,45 5,45 3,2 4 7,2 7,2 5,35 5,35 2,6 3,4 6,6 6,6 4,95 4,95 2,2 3 6,1 6,1 4,7 4,7 2,2 5 5 4,1 4,1 4,1 4,1 6,7 6,7 9,0 9,0 11,2 11,2 8,7 10,7 14,6 18 9,9 11,8 6,8 9 13,5 16,5 8,9 10,7 3,1 3,1 2,8 2,8 1,8 1,8 4,3 4,3 6,8 6,8 9,0 9,0 4,7 7,3 12,1 15,2 7,8 9,7 3,3 9 12 5,7 7,3 5,5 8,5 3,4 4,5 4,5 1,9 1,9 4,1 4,1 6,7 6,7
H (m)
23,8
22,8
22,3 25
20,8 24
20,6 22,9
19 22,3
* Available also with special stainless steel motor shaft version (SV).
MODEL
P2 Q NOMINAL m3/h kW HP l/min
0 0
3 50
6 12 18 24 36 48 60 72 84 96 102 120 138 150 162 180 210 240 270 300 360 420 516 100 200 300 400 600 800 1000 1200 1400 1600 1700 2000 2300 2500 2700 3000 3500 4000 4500 5000 6000 7000 8800
FEKA 2500.4 T FEKA 2500.2 T FEKA 2700.2 T FEKA 3000.4 T FEKA 3000.2 T FEKA 3500.2 T FEKA 3700.2 T FEKA 4000.4 T FEKA 4100.4 T FEKA 4100.2 T FEKA 4125.2 T FEKA 4150.2 T FEKA 4200.2 T FEKA 6075.6 T FEKA 6100.6 T FEKA 6120.6 T FEKA 6150.6 T FEKA 6200.4 T FEKA 6250.4 T FEKA 6300.4 T
1,8 1,8 2,2 3,7 3,7 4,4 5,5 6 7,5 7,5 9,2 11 15 5,5 7,5 8,8 11 15 18,5 22
2,5 2,5 3 5 5 6 7,5 8 10 10 12,5 15 20 7,5 10 12 15 20 25 30
9
8,85
8,75
8,4
17,8 7,2 11,9 10 14 12,2 8,5 8,2
5,4 5,9 8,3 7,4
2 3
15,5 15,3 18 9,5 18,7 22,3 25 15,3 17 17,6
14,9 13,6 17 15,6 8,9 17,5 20,4 24,1 23,4
6,5 9,5
5,6 6,4 10
4,6 4 7,5 14
3,6
2,4
1,8
16,6 15,4 12,6
19,1 17,9 15,2 12,8
5 10,8
2,5
22,6 21,9 20,2 18,5 16,5 14,3 13,7 12,9 16 12
11,2 10,3
9,3
8,8 10 7,6
7,1 8,3
5,5 6,5
4,3 5,2
3 4
15,2 14,7 13,8 12,8 11,8 10,6 8,4
H (m)
24 27 31 40 13 15 14 17 20 31 34,3 29,3 25,3 28 38,5
20,4 18,2 16,1 14,3 12,3 10,2
24,3 23,5 21,3 19,5 17,3 15,3 13,5 11,8 10,9 26,8 25,8 23,8 37,8 36,6 34,3 9,5 22 32 9,0 20 18,2 16 25 7,8 22 7,6 20,6 7,4 7,1 9,5 6,4 8,2 6,0 7,8 8,8 5,2 6,8 8,4 4,8 6,5 8,1 2,2 5,0 6,9 8,7 3,5 5,0 7,7 9,5 2,5 3,2 5,8 8,0 4,8 1,2
29,8 27,6 8,8 8,2
13,5 13,0 12,8 11,8 11,2 10,4 10,2
12,5 11,8 12,5 11,2 10,8 10,4 10,2 10,0 9,4
15,8 15,2 15,2 14,2 13,8 13,6 13,4 12,4 11,8 11,2 17,5 16,8 16,5 15,2 14,8 14,4 14,2 13,5 12,8 12,4 28,0 27,0 26,5 25,4 24,6 24,0 23,8 23,0 21,6 20,6 29,8 28,2 27,9 26,2 25,0 24,0 23,8 23,0 21,6 20,6
10,4 10,0
11,8 11,0 10,7
20,0 20,0 18,5 16,5 15,0 12,5 10,5 20,0 19,5 18,0 17,1 16,0 15,0 12,3 10,0 4,8
DAB PUMPS reserve the right to make modifications without prior notice
5
NOVA - FEKA
SUBMERSIBLE PUMPS FOR DRAINAGE AND WASTE WATER FOR DOMESTIC USE
GENERAL DATAApplicationsThe submersible pump from the NOVA series is designed mainly for automatically operated fixed applications in domestic use, draining basements and garages which are subject to flooding. Thanks to its compact, easy to handle form, it may also be used as a portable pump for emergencies such as lifting water from tanks or rivers, emptying swimming pools, fountains, excavations and underpasses. It is also ideal for gardening and hobbies in general. The submersible pump from the FEKA series has been designed for lifting sewage from cesspools and is capable of draining suspended solids with dimensions up to 25 mm. The level switch allows fixed installation and guarantees automatic pump operation. Available also with special stainless steel motor shaft version (SV).
Constructional features of the pumpWater-resistant technopolymer pump body, impeller, top body and suction grid. Stainless steel motor, rotor shaft and screws. Triple O-ring seals interposed with oil chamber.
Constructional features of the motorContinuous duty submersible induction motor. Stator fitted in an airtight stainless steel casing covered by a top body which contains the cabling, microswitch and capacitor. Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. Three-phase motors should be protected with a suitable overload protection complying with the regulations in force. Manufactured according to CEI 2-3 and CEI 61-69 standards (EN 60335-2-41). Motor protection: IP68 Insulation class: F Standard voltage: single-phase 220-240 V/50 Hz three-phase 400 V/50 Hz Standard cables for the single-phase version: NOVA 180 NOVA 600 10 metres H05 RN-F NOVA 180 10 metres H07 RN-F NOVA 600 5 metres H05 RN-F M-A M-A M-NA M-NA NOVA 300 FEKA 600 NOVA 200 FEKA 600 M-A M-A M-NA M-NA
Standard plug for the single-phase version: SCHUKO CEE 7 - VII - UNEL 47166-68 Standard cables for the three-phase version: 5 metres H07 RN-F
6
DAB PUMPS reserve the right to make modifications without prior notice
TECHNICALDATAN. 1 4 29 32 54 PARTS* PUMP BODY IMPELLER OR GASKET STOP RING MOTOR: TOP BODY ROTOR SHAFT MATERIALS TECHNOPOLYMER TECHNOPOLYMER NBR 12E - UNI 7435 STAINLESS STAINLESS STEEL AISI 304 X5 CrNi 1810 - UNI 6900/71 STAINLESS STEEL AISI 416 X12 CrS13 - UNI 6900/71 FOR SV SHAFT VERSION STAINLESS STEEL AISI 431 TECHNOPOLYMER TECHNOPOLYMER TECHNOPOLYMER29 54 83 78 4 32 79 1
78 PRESSURE DISC (FOR NOVA) 79 SUCTION GRID 83 FLOAT* In contact with the liquid
- Operating range: - Liquid quality requirements:
from 1 to 16 m3/h with head up to 10,2 metres NOVA cloudy water without fibres FEKA sewage from cesspools - Free passage of solids through the suction grid: NOVA 180 - NOVA 200 5 mm NOVA 300 - NOVA 600 10 mm FEKA 600 25 mm - Minimum draught depth: NOVA 180 77 mm NOVA 200 - NOVA 180 NA 8 mm NOVA 300 85 mm NOVA 600 A - FEKA 600 A 175 mm NOVA 600 NA - FEKA 600 NA 48 mm - Liquid temperature range: from 0C to +35C for domestic use (EN 60335-2-41) - Maximum immersion depth: 7 metres - Maximum dry running time: 1 minute - Installation: fixed or portable in a vertical position
MODEL NOVA 180 NOVA 200 NOVA 300 NOVA 600 FEKA 600
WITH FLOAT (A) YES NO YES YES YES
WITHOUTFLOAT(NA) YES YES NO YES YES
- Minimum pit dimensions for fixed installation with automatic operation:NOVA180 - NOVA300 NOVA600 - FEKA600
DAB PUMPS reserve the right to make modifications without prior notice
7
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 Kg/m3. Curve tolerance according to ISO 9906.
NOVA1800 0 4 4 8 8 12 12 16 20 16 Q US gpm Q IMP gpm
P kPa50
H m5
H ft16 14
40
4 12
30
NOVA 1803
10 8
20
2
6 4 2
10
1
0
0 0 0 0 20 1 0,5 40 2 3 1 60 80 4 5 1,5
0
Q m3/h Q l/s Q l/min
MODEL
A 181 148
B 235 148
C 46 46
D 296
E 82 82
H 253 253
H1 345
H2 38 38
LEV. MIN. 77
LEV. MAX 277
PACKING DIMENSIONS DNM L/A 11/4G 1 /4G1
L/B 202 202
H 320 320
VOLUME WEIGHT m3 Kg 0,019 0,019 4,6 4,5
NOVA 180 M-A NOVA 180 M-NA
287 287
ELECTRICAL DATA MODEL VOLTAGE 50 Hz 1x220-240 V P1 MAX W 190 P2 NOMINAL kW 0,20 HP 0,28 In A 0,9 CAPACITOR F 5 Vc 450 Q m3/h l/min H (m) Q 0 0 4,8
HYDRAULIC DATA (n 2850 1/min) Q Q Q 1,2 2,4 3,6 20 40 60 4,2 3,5 2,4
Q 4,8 80 1,4
NOVA 180 M
* Available also with special stainless steel motor shaft version (SV).
NOVA2000 0 5 5 10 10 15 20 15 25 20 30 25 35 30 40 35 45 40 50 Q US gpm 45 Q IMP gpm
P kPa70 60 50 40 30 20 10 0
H m7 6 5 4 3
H ft
18
16
NOVA 20012
8 2 1 0 0 0 0 40 2 1 80 4 6 2 120 160 8 10 3 200 12 4
0
Q m3/h Q l/s Q l/min
PACKING DIMENSIONS MODEL A 148 B 148 C 46 E 82 H 253 H2 38 DNM L/A L/B 202 H 320 11/4 G 287
VOLUME m3 0,019
WEIGHT Kg 4,5
NOVA 200 M-NA
ELECTRICAL DATA MODEL VOLTAGE 50 Hz 1x220-240 V P1 MAX W 350 P2 NOMINAL kW 0,22 HP 0,3 In A 1,5 CAPACITOR F 8 Vc 450 Q m3/h l/min H (m) Q 0 0 6,6
HYDRAULIC DATA (n 2850 1/min) Q Q Q Q 3 4,5 6 7,5 50 75 100 125 5,2 4,6 4 3,2
Q 9 150 2,6
Q 12 200 1,4
NOVA 200 M-NA
* Available also with special stainless steel motor shaft version (SV).
8
DAB PUMPS reserve the right to make modifications without prior notice
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 Kg/m3. Curve tolerance according to ISO 9906.
NOVA3000 0 5 5 10 10 15 20 15 25 20 30 25 35 30 40 35 45 40 50 Q US gpm 45 Q IMP gpm
P kPa70 60 50 40 30 20 10 0
H m7 6 5
H ft
18
NOVA 3004
16
12 3 8 2 1 0 0 0 0 40 2 1 80 4 6 2 120 160 8 10 3 200 12 4
0
Q m3/h Q l/s Q l/min
MODEL
A 181
B 235
C 46
D 296
E 82
H 262
H1 354
H2 47
LEV. MIN. 85
LEV. MAX 285
PACKING DIMENSIONS DNM L/A 11/4G 287 L/B 202 H 320
VOLUME WEIGHT m3 Kg 0,019 4,6
NOVA 300 M-A
ELECTRICAL DATA MODEL VOLTAGE 50 Hz 1x220-240 V P1 MAX W 355 P2 NOMINAL kW 0,22 HP 0,3 In A 1,6 CAPACITOR F 8 Vc 450 Q m3/h l/min H (m) Q 0 0 6,8 Q 3 50 5,6
HYDRAULIC DATA (n 2850 1/min) Q Q Q Q Q 4,5 6 7,5 9 10,8 75 100 125 150 180 5,1 4,6 4 3,4 2,7
Q 12 200 2,2
Q 13,02 217 1,7
NOVA 300 M-A
* Available also with special stainless steel motor shaft version (SV).
NOVA6000 0 10 10 20 20 30 30 40 50 40 60 50 0
P kPa100
H m10
Q US gpm Q IMP gpm H ft30
80
8
25
NOVA 60060 6 20
15 40 4 10H
DNM
20
2 5
H2
0C A B E
0 0 0 0 2 1 50 100 4 6 2 150 8 10 3 200 12 14 4 250 16
Q m3/h Q l/s Q l/min
0
MODEL
A 193 162
B 235 160
C 56 56
D 296
E 90 90
H 368 368
H1 443
H2 73 73
LEV. MIN. 190
LEV. MAX 390
PACKING DIMENSIONS DNM L/A 11/4G 11/4G 287 287 L/B 202 202 H 431 431
VOLUME WEIGHT m3 Kg 0,025 0,025 7 6,7
NOVA 600 M-A NOVA 600 (M-T)-NA
ELECTRICAL DATA MODEL VOLTAGE 50 Hz 1x220-240 V ~ 3x400 V ~ P1 MAX W 800 800 P2 NOMINAL kW 0,55 0,55 HP 0,75 0,75 In A 3,4 1,6 CAPACITOR F 14 Vc 450 Q m3/h l/min H (m) Q 0 0 10,2 Q 3 50 8,9
HYDRAULIC DATA (n 2850 1/min) Q Q Q Q Q 4,5 6 7,5 9 12 75 100 125 150 200 8,3 7,8 7,2 6,6 5
Q 15 250 3,1
Q 16,2 270 2,3
NOVA 600 M NOVA 600 T
* Available also with special stainless steel motor shaft version (SV).DAB PUMPS reserve the right to make modifications without prior notice
9
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 Kg/m3. Curve tolerance according to ISO 9906.
FEKA600
0 0
10 10
20 20
30 30
40
50 40
60 50
0 Q US gpm
P kPa70
H m7
Q IMP gpm H ft
60
6
20
FEKA 60050 5 16
40
4 12
30
3 8
20
2 4
DNM
H
10
1
0
0 0 0 0 2 1 50 100 4 6 2 150 8 10 3 200 12 14 4 250 16
Q m3/h Q l/s Q l/min
0
H2
C A B
E
MODEL
A 193 162
B 235 160
C 56 56
D 296
E 90 90
H 368 368
H1 443
H2 73 73
LEV. MIN. 190
LEV. MAX 390
PACKING DIMENSIONS DNM L/A 11/4G 11/4G 287 287 L/B 202 202 H 431 431
VOLUME WEIGHT m3 Kg 0,025 0,025 7 6,7
FEKA 600 M-A FEKA 600 (M-T)-NA
ELECTRICAL DATA MODEL VOLTAGE 50 Hz 1x220-240 V ~ 3x400 V ~ P1 MAX W 1000 970 P2 NOMINAL kW 0,55 0,55 HP 0,75 0,75 In A 4,3 1,7 CAPACITOR F 14 Vc 450 Q m3/h l/min H (m) Q 0 0 7,45 Q 3 50 6,45
HYDRAULIC DATA (n 2850 1/min) Q Q Q Q Q 4,5 6 7,5 9 12 75 100 125 150 200 6,1 5,7 5,35 4,95 4,1
Q 15 250 2,8
Q 15,9 265 2,2
FEKA 600 M FEKA 600 T
* Available also with special stainless steel motor shaft version (SV).
10
DAB PUMPS reserve the right to make modifications without prior notice
FEKA VS
SUBMERSIBLE CENTRIFUGAL PUMP
GENERALDATAApplicationsStainless steel submersible centrifugal pump with precision cast steel liquid vortex impeller, suitable for pumping sewer water and waste water in general containing solids up to a maximum size of 50 mm.
Constructional features of the pumpPump body, seal housing cover, motor casing, cap with handle made of stainless steel. Precision cast steel impeller. Handle coated with insulating rubber. AISI 304 stainless steel motor shaft. Double mechanical seal with interposed oil chamber (non-toxic oil), made of carbon/alumina on the motor side and silicon carbide/silicon carbide on the pump side.
Constructional features of the motorDry, asynchronous, sealed and cooled by the pumped liquid.Rotor mounted on greased for-life ball bearings, oversized and selected to guarantee greater noise reduction and duration. Thermo-amperometric protection as standard for single-phase version, and the users responsibility for the three-phase ver-sion. Constantly active capacitor on the single-phase version. Construction in accordance with the IEC 2-3 IEC 61-69 (EN 60335-2-41) standards. Motor protection class: IP 68 - Insulation class: F Standard voltage: 220-240V 50Hz Single-phase - 400V 50Hz Three-phase Continual running with liquid at 35 C and pump completely submerged. The single-phase version can be supplied with float for automatic function. Power supply cable: 10 metres of H07RN-F cable with Shuko plug for the single-phase version and 10 meters of H07RN-F cable for the three-phase version.
TECHNICALDATAN. 1 4 7 16 PUMP BODY IMPELLER MOTOR SHAFT MECHANICAL SEAL PUMP SIDE MOTOR SIDE PARTS* MATERIALS STAINLESS STEEL AISI 304 MICROCASTING STAINLESS STEEL STAINLESS STEEL AISI 316 SILICON CARBIDE/SILICON CARBIDE CARBON/ALLUMINA STAINLESS STEEL AISI 304 STAINLESS STEEL AISI 304 STAINLESS STEEL AISI 304 WITH INSULATING RUBBER COVER36
120
54 16 7 4 1
36 SEAL COVER 54 MOTOR CASING 120 HANDLE* In contact with the liquid
DAB PUMPS reserve the right to make modifications without prior notice
11
-
Operating range: from 0 a 32 m3/h with head up to 14 metres. Pumped liquid: sewer water and waste water in general and non aggressive. Liquid temperature range: - da 0C a +35C for domestic use (EN 60335-2-41) - da 0C a +50C for other uses Maximum ambient temperature for pump running with sub-merged motor: +40C Maximum immersion depth: 10 metri Installation: fixed or portable, vertical
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Fixed installation
700 x 700
FEKA VS 1200
ON
OFF
FEKA VS 550 FEKA VS 1000 FEKA VS 750
FEKA VS 550-750 FEKA VS 1000-1200
ON ON
670 mm 700 mm
OFF 270 mm OFF 300 mm
MODEL
A 203 203 203 203
B 170 170 170 170
D 172 172 172 172
H 492 492 537 537
H1 98 98 98 98
DNM 2"F 2"F 2"F 2"F
PACKAGING DIM. L/A 240 240 240 240 L/B 600 600 600 600 H 240 240 240 240
VOL m3 0,034 0,034 0,034 0,034
WEIGHT Kg 16,3 17,5 19,3 20,8
FEKA VS 550 FEKA VS 750 FEKA VS 1000 FEKA VS 1200
ELECTRICAL DATA MODEL VOLTAGE 50 HZ P1 max W 927 900 1111 1038 1469 1374 1936 1865 P2 Nominal kW 0,55 0,55 0,75 0,75 1 1 1,2 1,2 HP 0,75 0,75 1 1 1,36 1,36 1,6 1,6 In A Ist A CAPACITOR F 20 20 25 30 VC 450 7,4 3x400 V~ 1x220-240 V~ 3x400 V~ 1x220-240 V~ 3x400 V~ 1x220-240 V~ 3x400 V~ 1,64 5,13 1,94 6,63 2,51 8,63 3,44 11 20 11 31 16 38 22 450 9,6 450 11,8 450 14 13,4 11,3 H (m) 9,2 6,9 m /h l/min3
HYDRAULIC DATA (N 2800 1/min) 0 0 3 50 6 100 12 200 18 300 20 333 24 400 27 450 32 533
FEKA VS 550 M-NA FEKA VS 550 M-A FEKA VS 550 T-NA FEKA VS 750 M-NA FEKA VS 750 M-A FEKA VS 750 T-NA FEKA VS 1000 M-NA FEKA VS 1000 M-A FEKA VS 1000 T-NA FEKA VS 1200 M-NA FEKA VS 1200 M-A FEKA VS 1200 T-NA
1x220-240 V~
4,2
20
6,2
4,1
1,8
1,2
-
-
-
8,5
6,7
4,3
3,5
1,9
-
-
10,5
9
6,8
6
4,1
2,7
-
12,8
11,2
9
8,3
6,7
5,3
3
12
DAB PUMPS reserve the right to make modifications without prior notice
FEKA VX
SUBMERSIBLE CENTRIFUGAL PUMP
GENERALDATAApplicationsStainless steel submersible centrifugal pump with technopolymer liquid vortex impeller, suitable for pumping sewer water and waste water in general containing solids up to a maximum size of 50 mm.
Constructional features of the pumpPump body made of technopolymer, with threaded metal insert in the delivery port, seal housing cover, motor casing, cap with handle made of stainless steel. Technopolymer impeller. Handle coated with insulating rubber. AISI 304 stainless steel motor shaft. Double mechanical seal with interposed oil chamber (non-toxic oil), made of carbon/alumina on the motor side and silicon carbide/silicon carbide on the pump side.
Constructional features of the motorDry, asynchronous, sealed and cooled by the pumped liquid.Rotor mounted on greased for-life ball bearings, oversized and selected to guarantee greater noise reduction and duration. Thermo-amperometric protection as standard for single-phase version, and the users responsibility for the three-phase version. Constantly active capacitor on the single-phase version. Construction in accordance with the IEC 2-3 IEC 61-69 (EN 60335-2-41) standards. Motor protection class: IP 68 - Insulation class: F Standard voltage: 220-240V 50Hz Single-phase - 400V 50Hz Three-phase Continual running with liquid at 35 C and pump completely submerged. The single-phase version can be supplied with float for automatic function. Power supply cable: 10 metres of H07RN-F cable with Shuko plug for the single-phase version and 10 meters of H07RN-F cable for the three-phase version.
TECHNICALDATAN. 1 4 7 PUMP BODY IMPELLER MOTOR SHAFT PARTS* MATERIALS TECHNOPOLYMER TECHNOPOLYMER STAINLESS STEEL AISI 316 SILICON CARBIDE/SILICON CARBIDE CARBON/ALLUMINA STAINLESS STEEL AISI 304 STAINLESS STEEL AISI 304 STAINLESS STEEL AISI 304 WITH INSULATING RUBBER COVER36
120
MECHANICAL SEAL PUMP SIDE 16 MOTOR SIDE 36 SEAL COVER 54 MOTOR CASING 120 HANDLE* In contact with the liquid
54 16 7 4 1
DAB PUMPS reserve the right to make modifications without prior notice
13
-
Operating range: from 0 a 32 m3/h with head up to 14 metres. Pumped liquid: sewer water and waste water in general and non aggressive. Liquid temperature range: - da 0C a +35C for domestic use (EN 60335-2-41) - da 0C a +50C for other uses Maximum ambient temperature for pump running with sub-merged motor: +40C Maximum immersion depth: 10 metri Installation: fixed or portable, vertical
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Fixed installation
700 x 700
FEKA VX 1200
ON
OFF
FEKA VX 550 FEKA VX 1000 FEKA VX 750
FEKA VX 550-750 FEKA VX 1000-1200
ON ON
670 mm 700 mm
OFF 270 mm OFF 300 mm
MODEL
A 245 245 245 245
D 179 179 179 179
H 498 498 543 543
H1 98 98 98 98
DNM 2"F 2"F 2"F 2"F
PACKAGING DIM. L/A 360 360 360 360 L/B 600 600 600 600 H 320 320 320 320
VOL m3 0,069 0,069 0,069 0,069
WEIGHT Kg 16,7 17,9 19,6 21,1
FEKA VX 550 FEKA VX 750 FEKA VX 1000 FEKA VX 1200
ELECTRICAL DATA MODEL VOLTAGE 50 HZ P1 max W 927 900 1111 1038 1469 1374 1936 1865 P2 Nominal kW 0,55 0,55 0,75 0,75 1 1 1,2 1,2 HP 0,75 0,75 1 1 1,36 1,36 1,6 1,6 In A Ist A CAPACITOR F 20 20 25 30 VC 450 7,4 3x400 V~ 1x220-240 V~ 3x400 V~ 1x220-240 V~ 3x400 V~ 1x220-240 V~ 3x400 V~ 1,64 5,13 1,94 6,63 2,51 8,63 3,44 11 20 11 31 16 38 22 450 9,6 450 11,8 450 14 13,4 11,3 H (m) 9,2 6,9 m3/h l/min 0 0 3 50
HYDRAULIC DATA (N 2800 1/min) 6 100 12 200 18 300 20 333 24 400 27 450 32 533
FEKA VX 550 M-NA FEKA VX 550 M-A FEKA VX 550 T-NA FEKA VX 750 M-NA FEKA VX 750 M-A FEKA VX 750 T-NA FEKA VX 1000 M-NA FEKA VX 1000 M-A FEKA VX 1000 T-NA FEKA VX 1200 M-NA FEKA VX 1200 M-A FEKA VX 1200 T-NA
1x220-240 V~
4,2
20
6,2
4,1
1,8
1,2
-
-
-
8,5
6,7
4,3
3,5
1,9
-
-
10,5
9
6,8
6
4,1
2,7
-
12,8
11,2
9
8,3
6,7
5,3
3
14
DAB PUMPS reserve the right to make modifications without prior notice
DRENAG1000 - 1200STAINLESS STEEL SUBMERSIBLE PUMP
GENERAL DATAApplicationsStainless steel submersible pump with thrust ring type impeller, for draining clear waste water containing solids of maximum 10 mm diameter.
Pump construction characteristicsPump body, impeller, flange, filter and disk, motor casing, casing with handle and cabling compartment cover in stainless steel AISI 304. Stainless steel handle covered with insulating rubber. AISI 316 stainless steel motor shaft. Double mechanical seal with interposed non-toxic oil chamber, in carbon-aluminium motor side and silicon carbide-silicon carbide pump side.
Motor construction characteristicsDry asynchronous and waterproof type, cooled by pumped liquid. Rotor mounted on permanently lubricated ball bearings oversized and selected to guarantee silent operation and extended lifetime. Standard thermal switch protection device. Capacitor permanently fitted on single phase versions. Construction in compliance with CEI 2-3 - CEI 61-69 (EN 60335-2-41). Protection level: IP 68 Insulation class: F Standard power supply: 220-240V 50Hz single phase 400V 50Hz three phase Single phase version can be supplied with or without float for automatic operation. Power cable: 10 metres H07RN-F, with UNEL 47166-68 plug for single phase version. Operation range: Pumped liquid: from 3 to 28 m3/h with head up to 17 metres rain water, ground water, sandy water from construction site and clear waste water, non-aggressive in all cases. Liquid temperature range: - from 0C to +35C for domestic use (EN 60335-2-41) - from 0C to + 50C for other applications Max. ambient temperature for operation with motor emerged: +40C Max. immersion: 10 metres Installation: fixed or mobile, horizontal or vertical
DAB PUMPS reserve the right to make modifications without prior notice
15
TECHNICALDATAN. 1 4 7 16 36 42 54 69 92 PUMP BODY IMPELLER MOTOR SHAFT MECHANICAL SEAL SEAL COVER FILTER MOTOR CASING PUMP LINER FILTER COVER STAINLESS STEEL AISI 304 X5CrNi 1810 - UNI 6900/71 WITH INSULATING RUBBER COVER42 4 92 36 1
PARTS*
MATERIALS STAINLESS STEEL AISI 304 X5CrNi 1810 - UNI 6900/71 MICROCASTING STAINLESS STEELAISI 316 X5CrNiMo 1712 - UNI 6900/71 SILICON CARBIDE/SILICON CARBIDE CARBON/ALLUMINA120
PUMP SIDE MOTOR SIDE
69 54
STAINLESS STEEL AISI 304 X5CrNi 1810 - UNI 6900/71
16 7
120 HANDLE
* In contact with the liquid
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 Kg/m3. Curve tolerance according to ISO 9906.
0
10 10
20 20
30
40 30
50 40
60 50
70 60
80 70
90
100 80
110 90
P kPa180
H0 m
Q US gpm Q IMP gpm H ft
18
160
16 50
140
14
DRENAG 1200120 12 40
100
10
DRENAG 100080 8
30
60
6
20
40
4 10
20
2
0
0
0 0 0 50
4 1 100 2
8 3 150
12 4 200
16 5 300 250
20 6 350
24 7 400
28 450
Q m3/h Q l/s Q l/min
0
PACKAGING DIMENSIONS MODEL A C D H H1 DNM L/A L/B 600 H 250
VOLUME m3 0,034
WEIGHT Kg 17
DRENAG 1000 DRENAG 1200
215
175
71
413
385
1 1/2 F
240
18,5
ELECTRICAL DATA MODEL VOLTAGE 50 Hz 1x220-240 V ~ 3x400 V ~ 1x220-240 V ~ 3x400 V ~ P1 MAX KW 1,29 1,18 1,85 1,65 P2 NOMINAL kW 1 1 1,2 1,2 HP 1,36 1,36 1,6 1,6 In A 6 2,43 7,5 3,24 CAPACITOR F 25 30 Vc 450 15,3 450 H (m) 17 15,4 13,7 Q Q 0 m3/h l/min 0 3 50
HYDRAULIC DATA (N=2800 1/min) 6 100 12,1 9 150 10,5 12 200 8,7 15 250 6,8 18 300 4,7 21 350 2,4 23,5 392 0,5 28 465
DRENAG 1000 M DRENAG 1000 T DRENAG 1200 M DRENAG 1200 T
13,8
12,4
10,7
9
7,3
5,2
3,5
0,4
16
DAB PUMPS reserve the right to make modifications without prior notice
DRENAG1400 - 1800SUBMERSIBLE PUMP FOR USE ON BUILDING SITES
GENERAL DATAApplicationsSubmersible cast iron pump for use on building sites with thrust ring pipe impeller, designed for draining, lifting or transfer or sandy, muddy or sludgy water, ground water, rain water, fountain water, clean waste water, river or lake water containing solid bodies with maximum dimensions 12 mm.
Constructional features of the pumpCast iron pump body and motor casing. High-resistance cast iron thrust ring pipe impeller. Cast iron suction cover covered with abrasion-proof rubber. Stainless steel rotor shaft, handle, filter, filter cover and screws. Inspectable oil seal chamber. Silicon carbide mechanical seal. The supply vent of 2 threaded GAS is radial to facilitate assembly on the lifting devices (DSD 2).
Constructional features of the motorContinuous duty submersible induction motor, in a watertight casing. Rotor mounted on oversized greased sealed-for-life ball bearings. Thermal protection in the windings, to be connected to the control panel. In order to operate, the pumps must be equipped with a control and protection system, supplied separately and not connected to the electropumps. Supplied with 10 metres of neoprene rubber power cable 6x(4x1,5)+(2x0,5). Motor protection: IP68 Insulation class: F Manufactured according to CEI 2-3 standards. Standard voltage: single-phase 220-240 V/50 Hz three-phase 400 V/50 Hz
DAB PUMPS reserve the right to make modifications without prior notice
17
TECHNICALDATA
N. 1 4 7 10 16 28 29 35 42
PARTS* PUMP BODY IMPELLER MOTOR SHAFT MOTOR CASING MECHANICAL SEAL OR GASKET OR GASKET SUCTION COVER SUCTION FILTER
MATERIALS CAST IRON 200 UNI ISO 185 CAST IRON 200 UNI ISO 185 STAINLESS STEEL AISI 416 X12CrS13 - UNI 6900/71 CAST IRON 200 UNI ISO 185 SILICON CARBIDE VITON VITON CAST IRON 200 UNI ISO 185 STAINLESS STEEL AISI 304 X5CrNi 1810 - UNI 6900/71 CAST IRON 200 UNI ISO 185 STAINLESS STEEL AISI 304 X5CrNi 1810 - UNI 6900/71 STAINLESS STEEL AISI 304 X5CrNi 1810 - UNI 6900/71
77 PROTECTION COVER 92 FILTER COVER 120 HANDLE* In contact with the liquid
- Operating range:
from 6 to 33 m3/h with head up to 19,2 metres for the single-phase version and 21,5 metres for the three-phase version. sandy, muddy or sludgy water from building sites, clean waste water, rain water, ground water, fountain, river or lake water, always non aggressive from 0C to +55C 10 metres fixed or portable in a vertical position other voltages and/or frequencies
- Liquid quality requirements:
- Liquid temperature range: - Maximum immersion depth: - Installation: - Special executions on request:
- Free passage of solids through the suction grid: 12 mm
18
DAB PUMPS reserve the right to make modifications without prior notice
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 Kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range:
from 0C to +55
DRENAG 1400 - 1800
0 0 P kPa 200 H m 20
20 20
40 40
60 60
80
100 80
120 100
140 120
160
Q US gpm 140 Q IMP gpm H ft
180
60 18
DRENAG 1800 T160 16 50 140 14
DRENAG 1400 M120 12
40
100
10 30
80
8
60
6
20
40
4 10
(A) minimum level for continuous duty (B) minimum residual level in manual operation (C) minimum dimension of borehole base (D) minimum borehole height
20
2
0
0 0 0 0 6 2 100 200 12 4 300 18 6 400 24 8 500 30 36 10 600
0 Q m3/h Q l/s Q l/min
PACKING DIMENSIONS MODEL A B C 500x500 min 500x500 min D 600 min 600 min E F DNM H H1 L/A L/B 330 H 380
VOLUME WEIGHT m3 Kg 0,085 43,3
DRENAG 1400 M DRENAG 1800 T
500
90
150
219
2 G
584
144
680
500
90
150
219
2 G
584
144
680
330
380
0,085
44,2
ELECTRICAL DATA MODEL VOLTAGE 50 Hz 1x220-240 V ~ 3x400 V ~ P1 MAX kW 2 2,3 P2 NOMINAL kW 1,1 1,5 HP 1,5 2 In A 9,2 4,4 CAPACITOR F 40 Vc 450 Q m3/h l/min H (m) Q 0 0 19,2 21,5
HYDRAULIC DATA (n 2800 1/min) Q Q Q Q 6 12 18 24 100 200 300 400 17 20 14,6 18 12,1 15,2 9 12
Q 30 500 5,5 8,5
Q 36 600 4,5
DRENAG 1400 DRENAG 1800
DAB PUMPS reserve the right to make modifications without prior notice
19
FEKA1400 - 1800SUBMERSIBLE PUMPS FOR CESSPOOLS
GENERAL DATAApplicationsSubmersible cast iron pump with vortex backflowing impeller for cesspools. Suitable for lifting or drainage installations for sewage from cesspools and for generally dirty water containing solids up to maximum 38 mm diameter. Also suitable for ground water, rain water, clean and dirty waste water, river or lake water.
Constructional features of the pumpCast iron pump body, motor casing, suction cover and impeller. Stainless steel rotor, handle and screws. Inspectable oil seal chamber. Carbon/ceramic mechanical seal. The supply vent of 2 threaded GAS is radial to facilitate assembly on the lifting devices (DSD 2).
Constructional features of the motorContinuous duty submersible induction motor, in a watertight casing. Rotor mounted on oversized greased sealed-for-life ball bearings. Thermal protection in the windings, to be connected to the control panel. In order to operate, the pumps must be equipped with a control and protection system, supplied separately and not connected to the electropumps. Supplied with 10 metres of neoprene rubber power cable 6x(4x1,5)+(2x0,5). Motor protection: IP68 Insulation class: F Manufactured according to CEI 2-3 standards. Standard voltage: single-phase 220-240 V/50 Hz three-phase 400 V/50 Hz
20
DAB PUMPS reserve the right to make modifications without prior notice
TECHNICALDATA
N. 1 4 7 10 16 28 29 35 77 120
PARTS* PUMP BODY IMPELLER MOTOR SHAFT MOTOR CASING MECHANICAL SEAL OR GASKET OR GASKET SUCTION COVER PROTECTION COVER HANDLE
MATERIALS CAST IRON 200 UNI ISO 185 CAST IRON 200 UNI ISO 185 STAINLESS STEEL AISI 416 X12CrS13 - UNI 6900/71 CAST IRON 200 UNI ISO 185 CARBON/CERAMIC VITON VITON CAST IRON 200 UNI ISO 185 CAST IRON 200 UNI ISO 185 STAINLESS STEEL AISI 304 X5CrNi 1810 - UNI 6900/71
* In contact with the liquid
- Operating range:
from 6 to 30 m3/h with head up to 14 metres for the single-phase version and 15,5 metres for the three-phase version. dirty waste water, untreated sewage containing solids, always non aggressive from 0C to +55C
- Liquid quality requirements: - Liquid temperature range:
- Maximum ambient temperature for pump operation with the motor emerging: +40C - Free passage of solids: - Maximum immersion depth: - Installation: - Special executions on request: 38 mm 10 metres fixed or portable in a vertical position other voltages and/or frequencies
DAB PUMPS reserve the right to make modifications without prior notice
21
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range:
from 0C to +55C
FEKA 1400 - 1800
0 0 P kPa H m
20 20
40 40
60 60
80
100 80
120 100
140 120
160
Q US gpm 140 Q IMP gpm H ft
140
14
45
120
12
40
FEKA 1800 T35 100 10 30
FEKA 1400 M80 8 25
60
6
20
15 40 4 10 20 2 5
(A) minimum level for continuous duty (B) minimum residual level in manual operation (C) minimum dimension of borehole base (D) minimum borehole height
0
0
0 0 0
6 2 100
12 4 200
18 6 300
24 8 400
30
36 10 600
0 Q m3/h Q l/s Q l/min
500
PACKING DIMENSIONS MODEL A B C 500x500 min 500x500 min D 600 min 600 min E F DNM H H1 L/A L/B 330 H 380
VOLUME WEIGHT m3 Kg 0,085 41,2
FEKA 1400 M FEKA 1800 T
500
50
160
200
2 G
583
94
680
500
50
160
200
2 G
583
94
680
330
380
0,085
42,4
ELECTRICAL DATA MODEL VOLTAGE 50 Hz 1x220-240 V ~ 3x400 V ~ P1 MAX kW 1,8 1,9 P2 NOMINAL kW 1,1 1,5 HP 1,5 2 In A 8,5 3,7 CAPACITOR F 40 Vc 450 Q m3/h l/min H (m) Q 0 0 13,9 15,5
HYDRAULIC DATA (n 2800 1/min) Q Q Q 6 12 18 100 200 300 12 13,7 9,9 11,8 7,8 9,7
Q 24 400 5,7 7,3
Q 30 500 3,4 4,5
FEKA 1400 M FEKA 1800 T
22
DAB PUMPS reserve the right to make modifications without prior notice
GRINDER1400 - 1800SUBMERSIBLE PUMPS WITH TRITURATOR
GENERAL DATAApplicationsSubmersible cast iron pump with triturator suitable for lifting or drainage installations for civil and industrial sewage. Thanks to the grinding system, the material present in the sewage (organic waste, fabric, rubber, etc.) is reduced into small particles, allowing the liquid to be pumped without any risk of clogging or obstruction of the delivery pipes.
Constructional features of the pumpCast iron pump body, motor casing and suction cover. High-resistance cast iron thrust ring pipe impeller. Triturator device obtained by precision casting of extremely strong and durable materials. Stainless steel rotor shaft, handle and screws. Inspectable oil seal chamber. Silicon carbide mechanical seal. The supply vent of 2 threaded GAS is radial to facilitate assembly on the lifting devices (DSD 2).
Constructional features of the motorContinuous duty submersible induction motor, in a watertight casing. Rotor mounted on oversized greased sealed-for-life ball bearings. Thermal protection in the windings, to be connected to the control panel. In order to operate, the pumps must be equipped with a control and protection system, supplied separately and not connected to the electropumps. Supplied with 10 metres of neoprene rubber power cable 6x(4x1,5)+(2x0,5). Motor protection: IP68 Insulation class: F Manufactured according to CEI 2-3 standards. Standard voltage: single-phase 220-240 V/50 Hz three-phase 400 V/50 Hz
DAB PUMPS reserve the right to make modifications without prior notice
23
TECHNICALDATA
N. 1 4 7 10 16 28 29 35 77 120
PARTS* PUMP BODY IMPELLER MOTOR SHAFT MOTOR CASING MECHANICAL SEAL OR GASKET OR GASKET SUCTION COVER PROTECTION COVER HANDLE
MATERIALS CAST IRON 200 UNI ISO 185 CAST IRON 200 UNI ISO 185 STAINLESS STEEL AISI 416 X12CrS13 - UNI 6900/71 CAST IRON 200 UNI ISO 185 SILICON CARBIDE VITON VITON CAST IRON 200 UNI ISO 185 CAST IRON 200 UNI ISO 185 STAINLESS STEEL AISI 304 X5CrNi 1810 - UNI 6900/71 HARDENED STEEL AISI 440 HARDENED STEEL AISI 440
147 TRITURATOR FIXED PART FIXED PART 148 TRITURATOR FIXED PART ROTARY PART* In contact with the liquid
- Operating range:
from 2 to 9 m3/h with head up to 24,5 metres for the single-phase version and 26,5 metres for the three-phase version. dirty waste water, untreated sewage containing solids and/or long fibres, always non aggressive from 0C to +55C +40C 10 metres fixed or portable in a vertical position other voltages and/or frequencies
- Liquid quality requirements: - Liquid temperature range: - Maximum ambient temperature for pump operation with the motor emerging: - Maximum immersion depth: - Installation: - Special executions on request:
24
DAB PUMPS reserve the right to make modifications without prior notice
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range:
from 0C to +55C
GRINDER 1400 - 1800
0 0 P kPa H m
4 4
8 8
12 12
16
20 16
24 20
28 24
32 28
36 32
40 Q US gpm Q IMP gpm H ft
280
28
90
240
24
80
GRINDER 1800 T70 200 20
GRINDER 1400 M160 16
60
50
120
12
40
30 80 8 20 40 4 10
(A) minimum level for continuous duty (B) minimum residual level in manual operation (C) minimum dimension of borehole base (D) minimum borehole height
0
0
0 0 0
1
2 0,5 40
3 1 60
4
5 1,5 80
6
7 2
8
9 2,5 140
0 Q m3/h Q l/s Q l/min
20
100
120
PACKING DIMENSIONS MODEL A B C 500x500 min 500x500 min D 600 min 600 min E F DNM H H1 L/A L/B 330 H 380
VOLUME WEIGHT m3 Kg 0,085 43,2
GRINDER 1400 M GRINDER 1800 T
500
50
150
219
2 G
549
109
680
500
50
150
219
2 G
549
109
680
330
380
0,085
43,8
ELECTRICAL DATA MODEL VOLTAGE 50 Hz 1x220-240 V ~ 3x400 V ~ P1 MAX kW 1,95 2 P2 NOMINAL kW 1,1 1,5 HP 1,5 2 In A 8,7 3,8 CAPACITOR F 40 Vc 450 Q m3/h l/min H (m) Q 0 0 24,5 26,5
HYDRAULIC DATA (n 2800 1/min) Q Q Q Q 2 4 6 8 33,3 66,6 100 133,3 22,8 25 21 23,5 19 21,6 16,2 18,8
Q 9 150 14,1 17
GRINDER 1400 M GRINDER 1800 T
DAB PUMPS reserve the right to make modifications without prior notice
25
FEKA 2500-3000-4000-6000SUBMERSIBLE PUMPS FOR CESSPOOLS
GENERAL DATAApplicationsSubmersible cast iron pump with vortex backflowing impeller for cesspools. Suitable for lifting or drainage installations for sewage from cesspools and for generally dirty water containing solids (see technical particulars). Also suitable for ground water, rain water, clean and dirty waste water, river or lake water.
Constructional features of the pumpCast iron pump body, motor casing, suction cover and impeller. Stainless steel rotor and screws. Double mechanical seal with inspectable oil seal chamber. The flanged supply vent: 65 mm for 80 mm for 100 mm for 150 mm for FEKA 2500 - FEKA 2700 FEKA 3000 - FEKA 3500 - FEKA 3700 FEKA 4000 - FEKA 4125 - FEKA 4150 - FEKA 4200 FEKA 6075 - FEKA 6100 - FEKA 6120 - FEKA 6150 FEKA 6200 - FEKA 6250 - FEKA 6300 The pumps are supplied with threaded counter-flange (mass-produced). On request, lifting devices are available,they facilitate the pumps descent in the cesspools and allow to execute the maintenances without disassembling the
Constructional features of the motorContinuous duty submersible induction motor, in a watertight casing. Rotor mounted on oversized greased sealed-for-life ball bearings. Thermal protection in the windings, to be connected to the control panel. In order to operate, the pumps must be equipped with a control and protection system, supplied separately and not connected to the electropumps. Supplied with 10 metres of neoprene rubber power cable 6x(4x1.5)+(2x0.5). Motor protection: IP68 Insulation class: F Manufactured according to CEI 2-3 standards. Voltage: 3X400 V 50 Hz (fitted in for Feka 4100.4T - 4100.2T - 4150.2T - 4125.2T - 4200.2T, Feka 6075.6T Feka 6100.6T - Feka 6120.4T - Feka 6200.4T - Feka 6250.4T - Feka 6300.4T). Special executions on request: other voltages and/or frequencies, thermal protection in the windings and oil sensor (for all Feka 6000 models). Y
26
DAB PUMPS reserve the right to make modifications without prior notice
TECHNICALDATA77 29 10 4 7 16N. 1 4 7 PUMP BODY IMPELLER MOTOR SHAFT PARTS* MATERIALS CAST IRON 200 UNI ISO 185 CAST IRON 200 UNI ISO 185 STAINLESS STEEL AISI 416 X12CrS13 - UNI 6900/71 CAST IRON 200 UNI ISO 185 SILICON CARBIDE NBR NBR CAST IRON 200 UNI ISO 185 CAST IRON 200 UNI ISO 185 CAST IRON 200 UNI ISO 185
28
1 36
10 MOTOR CASING 16 MECHANICAL SEAL 28 OR GASKET 29 OR GASKET 35 SUCTION COVER 36 MECHANICAL SEAL 77 PROTECTION COVER* In contact with the liquid
35
- Operating range: - Liquid quality requirements:
from 7 to 516 m3/h in continuous duty with head up to 40 m; waste water, water in general containing solid bodies (view free passage in dimensions table), ground water, rain water, clean and black waste water, river or lake water, always non aggressive;
- Liquid temperature range: - Maximum immersion depth: - Installation:
from 0C to +55C 10 metres fixed or portable in a vertical position
DAB PUMPS reserve the right to make modifications without prior notice
27
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range: from 0C to +55C
FEKA 25000 0 P H kPa m 180 18 FEKA 2700.2T (2poli) 160 16 140 14 120 12C L
40 40
80 80
120 120
160
200 160
Q US gpm Q IMP gpm H ft 60
50
A
B
40 FEKA 2500.2T (2poli)
100 10 30 80 60 8 6 4 10M
FEKA 2500.4T (4 poli)
20
H
40 20 0E F G N O P
2 0 0 Q m3/h 14 Q l/s 800 Q l/min
0 0 0
8 2 200
16 4 6
24 8 400
32 10 600
40 12
48
Packing dimension of the pumpMODEL A B C D E G FREE PASSAGE OF SOLIDS mm WEIGHT Kg40
FEKA 2500.4T FEKA 2500.2T FEKA 2700.2T515 273 158 90 62 21/2 62
45 47
Dimensions with lifting deviceMODEL A B C D E F G H L M N O P
FEKA 2500.4T FEKA 2500.2T FEKA 2700.2TELECTRICAL DATA P2 ln NOMINAL A kW HP 1,8 1,8 2,2 2,5 2,5 3 4,6 4,8 5,4 HYDRAULIC DATA RPM 1/min. 1400 2800 2840 H (m) Q m3/h Lt./min. 0 0 9 15,5 18 6 100 8,75 14,9 17 12 200 8,4 13,6 15,6 18 300 7,8 11,9 14 24 400 7,2 10 12,2 36 600 5,4 5,9 8,3 48 800 2 3 3,9 80 190 3/4 2 /21
110
150
418
530
38
140
100
130
228
MODEL
VOLTAGE 50 Hz 3x400 V~ 3x400 V~ 3x400 V~
FEKA 2500.4T FEKA 2500.2T FEKA 2700.2T
28
DAB PUMPS reserve the right to make modifications without prior notice
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range: from 0C to +55C
FEKA 30000 0 P H kPa m 240 24 22 200 20A D F G
50 50
100 150 200 250 300 350 400 450 Q US gpm 100 150 200 250 300 350 Q IMP gpm H ft
FEKA 3700.2T (2 poli) 0
18 160 16 14 120 12 10H
60
50
40 FEKA 3000.2T (2 poli) 30 FEKA 3500.2T (2 poli) FEKA 3000.4T (4 poli)
80
8 6 20
L
40O T
4 10 2
I
0P B C R S Q
0
0 0 0
20 5 400
40 10 800 15
60 20 1200
80 25
100 1600
0 Q m3/h 30 Q l/s Q l/min
Packing dimension of the pumpMODEL A B 315 620 C 185 125 68 50 D E 82 3 G FREE PASSAGE OF SOLIDS mm 79 67 74 76 WEIGHT Kg 76 72 365 203
FEKA 3000.4T FEKA 3000.2T FEKA 3500.2T FEKA3700.2T
Dimensions with lifting deviceMODEL A B C D 315 353 110 422 330 175 180 2 700 480 375 240 150 390 638 220 F G H I L O P Q R S T
FEKA 3000.4T FEKA 3000.2T FEKA 3500.2T FEKA3700.2T
MODEL
VOLTAGE 50 Hz 3x400 V~ 3x400 V~ 3x400 V~ 3x400 V~
ELECTRICAL DATA P2 ln NOMINAL A kW HP 3,6 3,7 4,4 5,5 5 5 6 7,5 7,8 9,8 10 12
HYDRAULIC DATA RPM 1/min. 1400 2800 2910 2900 H (m) Q m3/h Lt./min. 0 0 9,5 18,7 22,3 25 12 200 8,9 17,5 20,4 23,4 18 300 8,5 16,6 19,1 22,6 24 400 8,2 15,4 17,9 21,9 36 600 7,4 12,6 15,2 20,2 48 800 6,5 9,5 12,8 18,5 60 1000 5,6 6,4 10 16,5 72 1200 4,6 4 7,5 14 5 10,8 2,5 84 1400 3,6 96 102 1600 1700 2,4 1,8
FEKA 3000.4T FEKA 3000.2T FEKA 3500.2T FEKA3700.2T
DAB PUMPS reserve the right to make modifications without prior notice
29
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range: from 0C to +55C
FEKA 40000 0 P H kPa m 400 40 360 36 320 32 100 280 28 FEKA 4150.2T (2 poli) 240 24 FEKA 4125.2T (2 poli) 200 20 FEKA 4100.2T (2 poli) 160 16 120 12 FEKA 4000.4T (4 poli) 80 40 0 8 4 0 0 100 120 140 160 180 Q m3/h 30 1500 2000 40 2500 50 Q l/s 3000 Q l/min FEKA 4100.4T (4 poli) 20 40 60 80 FEKA 4200.2T (2 poli) 100 100 200 200 300 400 300 500 400 600 500 700 600 Q US gpm Q IMP gpm H ft
120
0 0
20 500
40 10
60 20 1000
80
Packing dimension of the pumpMODEL A B C D E F G FREE PASSAGE OF SOLIDS mm 98 774 410 874 366 227 225 100 4 83 WEIGHT Kg 149 158 142 148 160 220
FEKA 4000.4T FEKA 4100.4T FEKA 4100.2T FEKA4125.2T FEKA4150.2T FEKA 4200.2T
Dimensions with lifting deviceMODEL A B C D E F G H I L M N O P Q R S T U
FEKA 4000.4T FEKA 4100.4T FEKA 4100.2T FEKA4125.2T FEKA4150.2T FEKA 4200.2TMODEL
355
110
520
774
547
227
410
185
225
300
200
2
4
420
180
280
460
730
VOLTAGE 50 Hz
ELECTRICAL DATA P2 ln NOMINAL A kW HP 6 7,5 7,5 9,2 11 15 8 10 10 12,5 15 20 15 20 22,5 26 23 31
HYDRAULIC DATA RPM 1/min. 1400 1400 2800 2930 2890 2920 Q m3/h Lt./min. 0 0 24 400 14,3 16 20,4 23,5 25,8 36,6 36 600 13,7 15,2 18,2 21,3 23,8 34,3 48 800 12,9 14,7 16,1 19,5 22 32 60 72 84 96 102 1000 1200 1400 1600 1700 12 13,8 14,3 17,3 20 29,8 11,2 12,8 12,3 15,3 18,2 27,6 10,3 9,3 11,8 10,6 10,2 8,4 13,5 10,9 16 25 22 8,8 10 7,6 120 2000 7,1 8,3 138 150 162 2300 2500 2700 5,5 6,5 4,3 5,2 3 4
Y Y Y Y Y
FEKA 4000.4T FEKA 4100.4T FEKA 4100.2T FEKA4125.2T FEKA4150.2T FEKA 4200.2T
3x400 V~ 3x400 V~ ( /) 3x400 V~ ( /) 3x400 V~ ( /) 3x400 V~ ( /) 3x400 V~ ( /)
15,3 17 24 H (m) 27 31 40
20,6
30
DAB PUMPS reserve the right to make modifications without prior notice
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range: from 0C to +55C
FEKA 6000
Packing dimension of the pumpMODEL A 950 1150 950 950 950 1150 1150 B 190 190 190 190 190 190 190 C 590 590 590 590 590 590 590 D 301 317 301 301 301 317 317 E 602 657 602 602 602 657 657 F 240 271 240 240 240 271 271 G 362 386 362 362 362 386 386 H 150 150 150 150 150 150 150 I DN 150 DN 150 DN 150 DN 150 DN 150 DN 150 DN 150 FREE PASSAGE OF SOLIDS mm 95 108 95 95 95 108 108 WEIGHT Kg 200 300 200 212 226 330 340
FEKA 6075.6T FEKA 6100.6T FEKA 6120.4T FEKA 6150.4T FEKA 6200.4T FEKA 6250.4T FEKA 6300.4T
Dimensions with lifting deviceMODEL A 810 871 810 810 810 871 871 B 240 271 240 240 240 271 271 C 570 600 570 570 570 600 600 D 970 1155 970 970 970 1155 1155 E 650 835 650 650 650 835 835 F 320 320 320 320 320 320 320 G 300 300 300 300 300 300 300 H 1100 1174 1100 1100 1100 1174 1174 I 70 70 70 70 70 70 70 L 2 2 2 2" 2 2 2 M 229 229 229 229 229 229 229 N DN 150 DN 150 DN 150 DN150 DN 150 DN 150 DN 150 O 450 450 450 450 450 450 450 P 70 70 70 70 70 70 70 Q 105 105 105 105 105 105 105 R 275 275 275 275 275 275 275
FEKA 6075.6T FEKA 6100.6T FEKA 6120.4T FEKA 6150.4T FEKA 6200.4T FEKA 6250.4T FEKA 6300.4T
MODEL
FEKA 6075.6T FEKA 6100.6T FEKA 6120.4T FEKA 6150.4T FEKA 6200.4T FEKA 6250.4T FEKA 6300.4T
ELECTRICAL DATA P2 ln NOMINAL A kW HP 3x400 V~ ( /) 5,5 7,5 12 3x400 V~ ( /) 7,5 10 19 3x400 V~ ( /) 8,8 12 23 3x400 V~ ( /) 11 15 26 3x400 V~ ( /) 15 20 31 3x400 V~ ( /) 18,5 25 37 3x400 V~ ( /) 22 30 46 VOLTAGE 50 Hz Y Y Y Y Y Y Y
HYDRAULIC DATA RPM m3/h 1/min. Lt./min. 950 950 1450 1450 1450 1450 1450Q
0 0 13 15 14 17 20 31 34,3
36 48 60 72 84 96 102 120 138 150 162 180 210 240 270 300 360 420 516 600 800 1000 1200 1400 1600 1700 2000 2300 2500 2700 3000 3500 4000 4500 5000 6000 7000 8600 9,5 13,5 12,5 16 17,5 28,0 29,8 9,0 13,0 11,8 15,8 16,8 27,0 28,2 8,8 12,8 12,5 15,2 16,5 26,5 27,9 8,2 11,8 11,2 14,9 15,2 25,4 26,2 7,8 11,2 10,8 14,4 14,8 24,6 25,0 7,6 10,4 10,4 13,9 14,4 24,0 24,0 7,4 10,2 10,2 13,4 14,2 23,8 23,8 7,1 9,5 10,0 12,4 13,5 23,0 23,0 6,4 8,2 9,4 11,8 12,8 21,6 21,6 6,0 7,8 8,8 11,2 12,4 20,6 20,6 5,2 6,8 8,4 10,8 11,8 20,0 20,0 4,8 6,5 8,1 10,0 11,8 20,0 19,5 2,2 5,0 6,9 8,2 11,0 18,5 18,0 3,5 5,0 7,7 10,7 16,5 17,1 2,5 3,2 5,8 9,5 15,0 16,0 1,2 4,8 8,0 12,5 10,5 15,0 12,3 10,0 4,8
H (m)
DAB PUMPS reserve the right to make modifications without prior notice
31
PROTECTION AND CONTROL SYSTEMS
SINGLE-PHASE VERSIONMODELMDN ED 1,3 MFEKA 600 M FEKA VS M FEKA VX M DRENAG 900 M
ED 3 M
ED 3 M Hs
E-BOX 2DFEKA 600 M FEKA VS M FEKA VX M DRENAG 900 M
E-BOX 2D 40 F
SOCCORRER
TYPE OF PUMP
DRENAG1400 M FEKA1400 M
DRENAG1400 M FEKA1400 M
GRINDER1400 M
DRENAG1400 M FEKA1400 M
TUTTE LE POMPE MONOFASE
N pump to be connected
1
1
1
1
2
2
1o2
Static torque increase
N float to be connected* Remote operation of luminous alarms or float alarms Man.-0-Auto. selector
1
1o2
1o2
1o2
2o3
2o3
1o2
THREE-PHASE VERSIONMODELED 1 T ED 1,5 T ED 2,5 TDRENAG1800 T FEKA1800 T GRINDER 1800 T FEKA2500.4 T FEKA2500.2 T FEKA2700.2 T
E-BOX 2DFEKA 600 T FEKA VS 550-750 T FEKA VX 550-750 T FEKA VS 1000-1200 T DRENAG900 T
E-BOX 2DDRENAG1800 T FEKA1800 T GRINDER 1800 T FEKA2500.4 T FEKA2500.2 T FEKA2700.2 T
TYPE OF PUMP
FEKA 600 T FEKA VS 550-750 T FEKA VX 550-750 T
FEKA VS 1000-1200 T FEKA VS 1000-1200 T DRENAG900 T
N pump to be connected N float to be connected* Remote operation of luminous alarms or float alarms Man.-0-Auto. selector* To be ordered separatly
1
1
1
2
2
1o2
1o2
1o2
2o3
2o3
32
DAB PUMPS reserve the right to make modifications without prior notice
PROTECTION AND CONTROL SYSTEMS
THREE-PHASE VERSIONMODELED 4 T ED 7,5 TFEKA 3000.2 T FEKA 3500.2 T FEKA3700.2 T FEKA 6075.6 T
ED 8 T
ED 15 TFEKA 4100.4 T FEKA4100.2 T FEKA 4150.2 T FEKA 6100.6 T FEKA 6120.4 T
ED 20 TFEKA 4125.2 T FEKA 4200.2 T FEKA 6200.4 T
ED 25 T
ED 30 T
TYPE OF PUMP
FEKA 3000.4 T
FEKA 4000.4 T
FEKA 6250.4 T
FEKA 6300.4 T
N pump to be connected
1
1
1
1
1
1
1
N float to be connected* Remote operation of luminous alarms or float alarms Man.-0-Auto. selector
1o2
1o2
1o2
1o2
1o2
1o2
1o2
Star-delta starting
THREE-PHASE VERSIONMODELE2D 8 T E2D 15 TFEKA 3000.2 T FEKA 3500.2 T FEKA3700.2 T FEKA 6075.6 T
E2D 16 T
E2D 30 TFEKA 4100.4 T FEKA4100.2 T FEKA 4150.2 T FEKA 6100.6 T FEKA 6120.4 T
E2D 40 T
E2D 50 T
E2D 60 T
TYPE OF PUMP
FEKA 3000.4 T
FEKA 4000.4 T
FEKA 4125.2 T FEKA 4200.2 T FEKA 6200.4 T
FEKA 6250.4 T
FEKA 6300.4 T
N pump to be connected
2
2
2
2
2
2
2
N float to be connected* Remote operation of luminous alarms or float alarms Man.-0-Auto. selector
2o3
2o3
2o3
2o3
2o3
2o3
2o3
Star-delta starting* To be ordered separatlyDAB PUMPS reserve the right to make modifications without prior notice
33
CONTROLMDN GENERAL DATAApplicationsControl unit for the protection and automatic and manual operation of DRENAG 1400 M and FEKA 1400 M single-phase electropumps. To be connected to a wall socket 2P+ 16 Amp 220-240 V a.c. with a block switch and fuse-carrier, using type AM fuses, 10-12 Amp.
CharacteristicsSupplied in a self-extinguishing plastic box, fitted with a bracket for wall mounting. Complete with: - micro circuit breaker with manual reset for overload protection; - thermal protection with automatic reset; - 40 F starting capacitor; - remote control switch to guarantee operation of an optional float (available on request); - terminal board for connecting the electropump and the float (if required, fed at 220-240V); - 1,5 m power cable H07RN-F 3G1,5 with EEC plug 17-2P+Earth (16A-220V); - plate showing the wiring diagram applied on the inside of the cover.
TECHNICAL DATA- Supply voltage - Phases - Frequency - Rated output power - Max. rated using current - Starting capacitor - Field of use environment temp. - Degree of protection - Storage temperature - Relative humidity of the air - Electric construction - E.M.C. (emissions) 220 - 240 V 1 50 Hz 1,1 kW - 1,5 HP 12 Amp 40 F-450 V -10C +40C IP55 -10C +60C MAX 95% EN 603204-1 and EN 60439-1 EN 55014 - EN 61000-3-2-1
DIMENSIONS (mm) MODEL A B 168 C 198 E 148
WEIGHT (Kg) 2,1
MDN
225
34
DAB PUMPS reserve the right to make modifications without prior notice
ED 1,3 M - ED 3 M GENERAL DATAApplicationsElectric panel for the protection and automatic operation by means of one or more floats of single-phase electropumps, like t is indicated in the following table:CONTROL PANEL ELECTROPUMP FEKA 600M, FEKA VS-VX 550 M-NA, FEKA VS-VX 750 M-NA, FEKA VS-VX 1000 M-NA, FEKA VS-VX 1200 M-NA, DRENAG 900M DRENAG 1400 M, FEKA 1400 M
ED 1,3 M ED 3 M
CharacteristicsSupplied in a thermoplastic self-extinguishing box, fitted with a bracket for wall mounting. The panel is selfprotected and it protects the electropump from overloads and short circuit breakers with manual reset (only for model ED 3 M). Complete with: - insulating switch of the supply line; - self-protected transformer for the supply at 24V of the external controls; - terminals for connecting the electropump and the control floats minimum/maximum ( or thrust meter etc.); - terminals for connecting the alarm float and for installing a remote acoustic or luminous alarm (without potential); - thermal protection with manual reset for connection to the KK leads from the motor (only for model ED 3 M); - button in front of the panel for the manual functioning of the electropump; - green signal in front the panel indicating the working pump.
TECHNICALDATA- Supply voltage: - Phases: - Frequency: - Rated output power: - Max. rated using current: - Starting capacitor: - Field of use environment temp.: - Storage environment temp. limit: - Relative humidity (without condensation): - Max. altitude: - Degree of protection: - Construction of the panels: 220 - 240 V +/- 10% 1 50 - 60 Hz ED 1,3 M 1,85 KW 220-240 V 10 Ampere ED 3 M 2,95 KW 220-240 V 16 Ampere 40 F
-10C +40C -25C +55C 50% at 40C max. (90% at 20C) 3000 m (a.s.l.) IP 55 according to EN 60204-1 and EN 60439-1
DIMENSIONS (mm) MODEL A B 245 245 C 270 270 D 300 300 E 190 190
WEIGHT (Kg) 5,6 5,6
ED 1,3 M ED 3 M
350 350
DAB PUMPS reserve the right to make modifications without prior notice
35
ED 3 M Hs GENERAL DATAApplicationsElectric panel for the protection and automatic operation by means of one or more floats of single-phase electropumps model GRINDER 1400 M in single installation.
CharacteristicsSupplied in a thermoplastic self-extinguishing box, fitted with a bracket for wall mounting. The panel is selfprotected and it protects the electropump from overloads and short circuit breakers with manual reset. Complete with: - insulating switch of the supply line; - automatic device for increasing static torque when starting with the possibility of regulation from 0,5 to 4 seconds (set from the constructor during the taring at 2 seconds). - self-protected transformer for the supply at 24V of the external controls; - terminals for connecting the electropump and the control floats minimum/maximum (or thrust meter etc.); - terminals for connecting the alarm float and for installing a remote acoustic or luminous alarm (without potential); - thermal protection with manual reset for connection to the KK leads from the motor; - button in front of the panel for the manual functioning of the electropump; - green signal in front the panel indicating the working pump.
TECHNICALDATA- Supply voltage: - Phases: - Frequency: - Rated output power: - Max. rated using current: - Starting capacitor: - Starting capacitor: - Field of use environment temp.: - Storage environment temp. limit: - Relative humidity (without condensation): - Max. altitude: - Degree of protection: - Construction of the panels: 220 - 240 V +/- 10% 1 50 - 60 Hz 2,95 KW 220-240 V 16 Ampere 40 F - 450 V 200-250 F - 320 V -10C +40C -25C +55C 50% at 40C max. (90% at 20C) 3000 m (a.s.l.) IP 55 according to EN 60204-1 and EN 60439-1
DIMENSIONS (mm) MODEL A B 335 C 270 D 390 E 190
WEIGHT (Kg) 6,9
ED 3 M Hs
350
36
DAB PUMPS reserve the right to make modifications without prior notice
E-BOX 2D M / T GENERAL DATAApplications
-
E-BOX 2D M 40 F
Control panel for the protection and automatic operation, with floats or level sensor control, of two singlephase or three-phase (direct starting) electric pumps installed as a pair. Thanks to the facility for pump current control (1-12 A) the E- Box control panel is compatible with a large number of different pump models. E-box can control one or more pumps.PANEL ELECTRIC PUMP
E-BOX 2D E-BOX 2D 40 F E-BOX 2D
SINGLEPHASE THREEPHASE
FEKA 600 M, FEKA VS M, FEKA VX M, DRENAG 900 M DRENAG 1400 M, FEKA 1400 M FEKA 600 T, FEKA VS 550-750 T, FEKA VX 550-750 T, FEKA VS 1000-1200 T, DRENAG 900 T, DRENAG 1800 T, FEKA 1800 T, GRINDER 1800 T, FEKA 2500.4 T, FEKA 2500.2 T, FEKA 2700.2 T
FeaturesSupplied in a self-extinguishing thermoplastic enclosure, complete with wall mounting brackets. The control panel protects the pumps from overloads and short-circuit conditions, with manual reset, and overtemperature conditions with automatic reset. Front panel components: - main disconnect switch with padlockable doorlock - AUT - 0 - MAN operating mode selection buttons - alarms RESET button - run, trip and alarm indicator lights Components inside the control panel enclosure: - control circuit board, fuses, contactors - terminals for single phase (L-N) or three-phase (L1-L2-L3) power feeding input - terminals for connection of single-phase (L-N) or three-phase (U-V-W) electric pumps - terminals for connection to pressure switches, sensors, KK thermal protection, alarm signalling N.O. contacts - mini dipswitches for operating mode selection float switches or level sensors, filling or emptying of tanks, operation with one or two pumps. E-Box functions The E-Box control panel protects the electric pumps and starts them in sequence in relation to the filling or emptying of the tanks, with water level detection system by means of level sensors or 2 - 3 float switches (standard or bulb type). At each operating cycle the pumps starting sequence is inverted. E-box can also control just one pump by setting the dipswitches appropriately. Operation with two float switches The two float switches system must be used in cases in which the dimensions of the water collection tank allow sufficient travel of the floats. Float switch B enables operation of the first pump, float switch C starts also the second pump. The two pumps are stopped when the contact of float switch B opens. Operation with three float switches The three float switches system, which is to be preferred because of the precision of pumps starting and stopping, is recommended in cases wherein the tank diameter is limited such as to obstruct regular travel of the floats. Float switch B enables operation of the first pump, float switch C starts also the second pump. The two pumps are stopped when the contact of the third float switch A opens. Operation with level sensor Level sensor systems are recommended in cases wherein it is not possible to use the float switch (narrow tank / sump, sewage, etc.) Pump start and stop functions are selected by means of two trimmers: - SP: tank max level (in metres) - DP: tank min/max level (in percentage with respect to Sp)DAB PUMPS reserve the right to make modifications without prior notice
37
Emptying function: the first pump starts after level SP (e.g. 2 m) is surpassed; if the tank level does not fall, after 5 seconds also the second pump is started to assist the first one. The two pumps are stopped on the basis of the SP - DP value (e.g. with DP= 50%, pumps stop at 2 metres - 50% = 1 metre). Filling function: the first pump starts when level DP falls (e.g. SP= 2 metres, DP= 50% pump starts at 2 m - 50% = 1 metre), if the tank level does not increase, after 5 seconds also the second pump is started to assist the first one. The two pumps are stopped on the basis of the SP value (e.g. 2 metres).
TECHNICAL DATANominal power supply voltage Frequency Maximum operating power Maximum operating current Start capacitor (E-BOX 2D M40 F only) Operating environmental temperature limits Storage temperature limits Air relative humidity Max. altitude Protection rating Control panel construction reference standard 1x230 V - 3x230 V - 3x400 V (selectable) 50 - 60 Hz 5.5 kW + 5.5 kW 12 A + 12 A 40 microfarads -10 C + 40 C -25 C + 55 C 90% at 20 C 100 m above sea level IP 55 EN 60335-1
C E D
A
A1
B B1
DIMENSIONS (mm) MODEL A A1 265 265 B 282 282 B1 337 337 C 320 320 D 260 260 E 120 120
GROSS WEIGHT (Kg)
E-BOX 2D M / T E-BOX 2D M 40 F
212 212
38
DAB PUMPS reserve the right to make modifications without prior notice
SOCCORRER
GENERAL DATAApplicationsSOCCORRER systems are suitable for civil and industrial installations wherein a 230 V single-phase electric pump must be powered and a temporary power loss may result in flooding of rooms located under the level of the water-drainage system, resulting in possible damage to property or personal injury. The new SOCCORRER systems are composed of two main parts: a metal bracket with wall fixing system and a body made of self-extinguishing ABS. The innovative styling of these ensures that they are suitable for installation in all types of surroundings.
OPERATIONSOCCORRER systems are completely automatic because they are controlled by a high performance microprocessor capable of administrating: Mains power loss and the need to switch to battery power Battery type and charge level Battery charging in the shortest possible time Starting and stopping of the electric pumps (also by means of a safety float switch) Current monitoring protection system Electric pump overloads Automatic reset of the electric pumps Pump dry running protection Manual and automatic self-test routines Voltage free contact for remote alarm signal
SOCCORRER systems are available with a single output (one electric pump) or dual output (two electric pumps). In the dual output version operation of the electric pumps can be alternated or simultaneous.
SUPPLYSOCCORRER systems are supplied complete with: anti-flood controller, battery connection cables, sealed batteries, and battery mounting racks. The float switch is supplied separately, although it is required for operation in conjunction with non-automatic DAB pumps.
DAB PUMPS reserve the right to make modifications without prior notice
39
SOCCORRER selection tablesCORRECT SELECTION OF THE SOCCORRER FLOOD PROTECTION SYSTEM1. In the RUN TIME TABLE, find the maximum exposed area in compliance with the requirements of the application this allows us to choose the pump* (pumps must be ordered separately) 2. Now follow the column to find the required run time in minutes in order to select the correct SOCCORRER complete with batteries. 3. in the ACCESSORIES table, identify the devices required for correct installation on the basis of the pump and SOCCORRER models * for heads in excess of 3 metres it is good practice to check the working point of the pumpsNOVA 180 NOVA 200 NOVA 300 NOVA 600 FEKA 600 FEKA VS - VX 550 FEKA VS - VX 750
(minutes)TOTAL EXPOSED AREA (m2) MODEL Operation SINGLE OUTPUT (1 pump) SINGLE OUTPUT (1 pump) DUAL OUTPUT (2 pumps running alternately) SINGLE OUTPUT (2 pumps running simultaneously) DUAL OUTPUT (2 pumps running simultaneously)
PUMP MODEL
SOCCORRER RUN TIMES TABLES **
40 No. of batteries 4 x 18 Ah 2 x 45 Ah 2 x 60 Ah 2 x 45 Ah 2 x 60 Ah 2 x 45 Ah 106 166 230 83 115
95
125
190
150
160
230
SOCCORRER 500 SOCCORRER 600
63 100 138 x x
60 93 129 x x 47 65 123 49 88 x x x 95 1 72 x x x x x 98 176 x x 80 144 x x
SOCCORRER 1000 PLUS
SINGLE OUTPUT (1 pump) DUAL OUTPUT (2 pumps running alternately)
2 x 60 Ah 2 x 100 Ah 2 x 45 Ah 54 73 140 50 66 130
x x x 121 218 x x
SINGLE OUTPUT (2 pumps running simultaneously) DUAL OUTPUT (2 pumps running simultaneously)
2 x 60 Ah 2 x 100 Ah
SOCCORRER 1500
SINGLE OUTPUT (1 pump) DUAL OUTPUT (2 pumps running alternately) SINGLE OUTPUT (2 pumps running simultaneously) DUAL OUTPUT (2 pumps running simultaneously) SINGLE OUTPUT (1 pump) DUAL OUTPUT (2 pumps running alternately) SINGLE OUTPUT (2 pumps running simultaneously) DUAL OUTPUT (2 pumps running simultaneously) SINGLE OUTPUT (1 pump) DUAL OUTPUT (2 pumps running alternately) SINGLE OUTPUT (2 pumps running simultaneously) DUAL OUTPUT (2 pumps running simultaneously) SINGLE OUTPUT (1 pump) DUAL OUTPUT (2 pumps running alternately) SINGLE OUTPUT (2 pumps running simultaneously) DUAL OUTPUT (2 pumps running simultaneously) SINGLE OUTPUT (1 pump) DUAL OUTPUT (2 pumps running alternately) SINGLE OUTPUT (2 pumps running simultaneously) DUAL OUTPUT (2 pumps running simultaneously)
4 x 60 Ah 4 x 100 Ah 4 x 60 Ah 4 x 100 Ah 4 x 60 Ah 4 x 100 Ah 4 x 60 Ah 4 x 100 Ah 4 x 60 Ah 4 x 100 Ah 4 x 60 Ah 4 x 100 Ah 4 x 60 Ah 4 x 100 Ah 4 x 60 Ah 4 x 100 Ah 4 x 180 Ah 4 x 180 Ah
SOCCORRER 2000
60 106
x x
x x
x x
SOCCORRER 2500
47 84
48 86
x x
SOCCORRER 3000
40 74 284 142
SOCCORRER 4000
** To ensure the maximum performance of the system use exclusively the Soccorrer-pump combinations indicated above.
40
DAB PUMPS reserve the right to make modifications without prior notice
SOCCORRER selection tablesFEKA VS - VX 1000 FEKA VS - VX 1200 DRENAG 1000 DRENAG 1200 DRENAG 1400 FEKA 1400
(minutes)TOTAL EXPOSED AREA (m2) MODEL OPERATION
PUMP MODEL
SOCCORRER RUN TIMES TABLES **
300 No. of batteries 4 x 60 Ah 62
310
230
300
385
385
SOCCORRER 2000
68
55
SINGLE OUTPUT DUAL OUTPUT (for alternate operation) 4 x 100 Ah 109 120 96
SOCCORRER 2500
4 x 60 Ah SINGLE OUTPUT DUAL OUTPUT (for alternate operation) 4 x 100 Ah
47
44
47
83
78
85
SOCCORRER 3000
4 x 60 Ah SINGLE OUTPUT DUAL OUTPUT (for alternate operation) 4 x 100 Ah
4 x 100 Ah SINGLE OUTPUT DUAL OUTPUT (for alternate operation)
SOCCORRER 4000DUAL OUTPUT (simultaneaous)
4 x 180 Ah
220
169
243
195
159
172
4 x 100 Ah
57
x
63
51
x
x
4 x 180 Ah
110
x
122
97
x
x
4 x 100 Ah SINGLE OUTPUT DUAL OUTPUT (for alternate operation)
SOCCORRER 5000DUAL OUTPUT (simultaneaous)
4 x 180 Ah
4 x 100 Ah
44
41
45
4 x 180 Ah
83
78
85
** To ensure the maximum performance of the system use exclusively the Soccorrer-pump combinations indicated above.
OPTIONAL ACCESSORIES TO BE ORDERED SEPARATELY1 FLOAT 2 FLOAT MDM CONTROL PANEL SEALED BATTERIES AUDIBLE VISUAL ALARM
TABLE OF ACCESSORIES
PUMP TYPE
M-NA
M-A
M-NA
M-A
FEKA 1400M DRENAG 1400 M
SINGLE OUTPUT
SOCCORRER
DUAL OUTPUT FOR ALTERNATE OPERATION DUAL OUTPUT FOR SIMULTANEOUS OPERATION
OBLIGATORY
SAFETY/OPTIONAL
NOT NECESSARY
DAB PUMPS reserve the right to make modifications without prior notice
41
SOCCORRERMAIN DISPLAY INDICATIONSSoccorrer systems are equipped with an intuitive display with guided software that presents the following information: Line voltage in V (Volt); Pump power draw with mains power present in VA (Volt Amperes); Batteries charge current with mains power present in A (Amperes); Batteries voltage in V (Volt); Maximum overload current expressed in A (Amperes); Number of pump starts in the presence of mains power; Number of pump starts using battery power; Run time of pump expressed in hours and minutes using battery power; Total run time of pump expressed in hours and minutes (batteries + mains); Number of hours and run time, user programmable, to perform self-test routine (only for pumps with float switch connected directly to the system); Serial number; Microprocessor version. MACHINE DATA TEST HISTORIC
MODEL
ln A
ELECTRICAL DATA P2 NOMINAL kW 0,22 0,22 0,22 0,22 0,55 0,55 0,55 0,55 0,55 0,55 0,75 0,75 1,00 1,00 1,20 1,20 1 1,2 1,1 1,1 HP 0,3 0,3 0,3 0,3 0,75 0,75 0,75 0,75 0,75 0,75 1 1 1,36 1,36 1,60 1,60 1,36 1,6 1,5 1,5
HYDRAULIC DATAQ m3/h Lt./min.
0 0 4,95 4,95 7,1 7,18 10,2 10,2 7,45 7,45 7,4 7,4 9,6 9,6 11,8 11,8 14 14 15,3 17 19,2 13,9
1 16,6 4,45 4,45 6,6 6,7 9,7 9,7 7,1 7,1 7,3 7,3 9,5 9,5 11,7 11,7 13,9 13,9
2 33,3 3,9 3,9 6,1 6,23 9,3 9,3 6,75 6,75 7,2 7,2 9,4 9,4 11,6 11,6 13,8 13,8
3 50 3,15 3,15 5,6 5,8 8,9 8,9 6,45 6,45 6,9 6,9 9,2 9,2 11,3 11,3 13,4 13,4 13,7 15,4
4,5 75 1,7 1,7 4,9 5,2 8,3 8,3 6,1 6,1 6,7 6,7 9,0 9,0
5 83,3 1,15 1,15 4,7 5 8,1 8,1 5,95 5,95 6,6 6,6 8,9 8,9
6 100
7 7,5 116,6 125
9 10 150 166,6
12 200
15 250
18 300
24 400
30 500
NOVA180 M-A NOVA180 M-NA NOVA200 M-NA NOVA300 M-A NOVA600 M-A NOVA600 M-NA FEKA600 M-A FEKA600 M-NA FEKAVS-VX 550 M-A FEKAVS-VX 550 M-NA FEKAVS-VX 750 M-A FEKAVS-VX 750 M-NA FEKAVS-VX 1000 M-A FEKAVS-VX 1000 M-NA FEKAVS-VX 1200 M-A FEKAVS-VX 1200 M-NA DRENAG1000 M-A / M-NA DRENAG1200 M-A / M-NA DRENAG1400 M FEKA1400 M
0,9 0,9 1,5 1,6 3,4 3,4 4,3 4,3 4,2 4,2 5,13 5,13 6,63 6,63 8,63 8,63 6 7,5 9,2 8,5
4,2 4,6 7,8 7,8 5,7 5,7 6,2 6,2 8,5 8,5
3,7 4,2 7,4 7,4 5,45 5,45 6,0 6,0 8,3 8,3 10,3 10,3 12,6 12,6 11,5 13,4 16,5 11,6
3,5 4 7,2 7,2 5,35 5,35 5,9 5,9 8,2 8,2 10,2 10,2 12,5 12,5 11,2 13 16,3 11,4
2,8 3,42 6,6 6,6 4,95 4,95 5,6 5,6 7,6 7,6 9,8 9,8
2,35 3 6,1 6,1 4,7 4,7 5,2 5,2 7,2 7,2 9,4 9,4
1,5 2,2 5 5 4,1 4,1 4,1 4,1 6,7 6,7 9,0 9,0 11,2 11,2 8,7 10,7 14,6 9,9 3,1 3,1 2,8 2,8 3,2 3,2 5,6 5,6 8,0 8,0 10,1 10,1 6,8 9 8,9 1,8 1,8 4,3 4,3 6,8 6,8 9,0 9,0 4,7 7,3 7,8 3,3 9 5,7 5,5 3,4 1,9 1,9 4,1 4,1 6,7 6,7
H (m)
11,1 11,0 10,5 11,1 11,0 10,5 13,2 13,0 12,8 13,2 13,0 12,8 13,2 13 12,1 17 12 14,7 14,5 13,8
12,0 11,6 12,0 11,6 10,5 10 12,4 11,8 15,9 15,6 11 10,8
13,5 12,1
42
DAB PUMPS reserve the right to make modifications without prior notice
SOCCORRER technical data and configurationsTECHNICAL DATA SOCCORRER SOCCORRER SOCCORRER SOCCORRER SOCCORRER SOCCORRER SOCCORRER SOCCORRER SOCCORRER 500 600 1000 PLUS 1500 2000 2500 3000 4000 5000 230 V (+6% / -10%) - 50 Hz 230 V (+6% / -10%) - 50 Hz Stepwave 48 Vcc 40 Vcc 90% 24 Vcc 20 Vcc 85% 1 second Automatic 500 VA 2,2 1,9 10 600 VA 2,6 2,3 10 1000 VA 4,4 3,8 15 1500 VA 6,5 5,7 20 2000 VA 8,7 7,6 25 -20 C - 60 C5
POWERSUPPLYVOLTAGE OUTPUT VOLTAGE WAVEFORM BATTERYVOLTAGE BATTERY OPERATINGLIMITS EFFICIENCY CUT-IN TIME MAINS-BATTERY SWITCHING MAX. POWER OUTPUT (VA) MAX.CURRENT OUTPUT (A) MAX. PUMPMOTOR CURRENT (A) MAX. PEAK CURRENT (A) TEMPERATURERANGE HUMIDITY PROTECTIONRATING DIMENSIONS L X H X P (mm) MATERIAL WEIGHT (Kg)
48 Vcc 40 Vcc 88%
2500 VA 11 9,6 30
3000 VA 13 11,5 30
4000 VA 17,4 15,2 50
5000 VA 22 20 50
5 90% not condensed IP 21 285 x 520 x 210
Steal bearing structure and self-extinguishing ABS coating 32 18 24 30 36 40 44 46 55
CONFIGURATIONS SINGLE OUTPUT (1 pump)THE SOCCORRER KIT includes; anti-flood controller configured to control 1 electric pump sealed batteries * batteries-holder rack (except for 180 Ah batteries) cables kit for batteries connection instruction manual
The pumps, float switches and other accessories must be ordered separately. * Included for the Soccorrer 500 model
DUAL OUTPUT (2 pumps)THE SOCCORRER KIT includes; anti-flood controller configured to control 2 electric pumps sealed batteries batteries-holder rack (except for 180 Ah batteries) cables kit for batteries connection instruction manual
The pumps, float switches and other accessories must be ordered separately.DAB PUMPS reserve the right to make modifications without prior notice
43
SOCCORRER accessoriesFLOATFloat 5 metres 10 metres 15 metres 20 metres
MDN CONTROLLERController for protection and automatic operation of single-phase electric pumps type DRENAG 1400M and FEKA 1400M. Supplied in a self-extinguishing plastic enclosure, equipped with pre-mounted wall bracket. Complete with manually resettable micro disconnect for overload protection, automatic reset thermal protection and start capacitor.
DIMENSIONS (mm) MODEL L H 168 P 148
Weight Kg 2,1
CONTROL MDN
198
BATTERY HOLDER COVERBattery holder rack cover in non-toxic self-extinguishing polycarbonate User protection against accidental contact with battery terminals High level of impact resistance.DIMENSIONS (mm) MODEL L H 230 P 265 Weight Kg 1
BATTERY HOLDER COVER
395
SEALED BATTERIES Hermetically sealed batteries Maintenance-free Longer life Power check for visual charge status monitoring Lead/Calcium/Tin technology Double heat-sealed cover with integral Flame Arrest tablet Anti-corrosion terminals Case bottom with Flex Ribs to absorb vibration Nominal voltage 12VDC Average battery life 4 5 years.DIMENSIONS (mm) MODEL L H 190 190 P 175 175 Weight Kg 14,4 23,3
Batteria 60Ah Ermetica Batteria 90Ah Ermetica
242 352
AUDIBLE AND VISUAL ALARMFlashing siren powered by the anti-flood system batteries, complete with trip float switch.
44
DAB PUMPS reserve the right to make modifications without prior notice
ED 1 T - ED 1,5 T - ED 2,5 T GENERAL DATAApplicationsElectric panels for the protection and automatic operation by means of one or more floats of single-phase electropumps, like t is indicated in the following table:CONTROL PANEL ELECTROPUMP FEKA 600 T, FEKA VS-VX 550 T-NA, FEKA VS-VX 750 T-NA FEKA VS-VX 1000 T-NA, FEKA VS-VX 1200 T-NA, DRENAG 900 T DRENAG 1800 T, FEKA 1800 T, GRINDER 1800 T, FEKA 2500.4 T, FEKA 2500.2 T, FEKA 2700.2 T
ED 1 T ED 1,5 T ED 2,5 T
CharacteristicsSupplied in a thermoplastic self-extinguishing box, fitted with a bracket for wall mounting. The panel is selfprotected and it protects the electropump from overloads and short circuit breakers with manual reset (only for model ED 2,5 T paired off to Drenag/Feka/Grinder 1800). Complete with: - insulating switch of the supply line; - self-protected transformer for the supply at 24V of the external controls; - terminals for connecting the electropump and the control floats minimum/maximum (or thrust meter etc.); - terminals for connecting the alarm float and for installing a remote acoustic or luminous alarm (without potential); - thermal protection with manual reset for connection to the KK leads from the motor (only for model ED 2,5 T, fit a jumper when using it with Feka 2500.4 T - 2500.2 T - 2700.2 T); - switch in front the panel for the manual functioning - o - automatic of the electropump; - signalling in front the panel: - luminous red signal which indicates the intervention of the amperometric protection; - luminous green signal which indicates that the pump is working; - luminous white signal which indicates the correct functioning of the auxiliaries circuits.
TECHNICALDATA- Supply voltage: - Phases: - Frequency: - Rated output power: - Max. rated using current: - Field of use environment temp.: - Storage environment temp. limit: - Relative humidity (without condensation): - Max. altitude: - Degree of protection: - Construction of the panels: 400 V +/- 10% 3 50 - 60 Hz ED 1T ED 1,5 T 1,38 KW 2,2 KW 2,5 A 4A ED 2,5 T 3,5 KW 6,3A
-10C +40C -25C +55C 50% at 40C max. (90% at 20C) 3000 m (a.s.l.) IP 55 according to EN 60204-1 and EN 60439-1
DIMENSIONS (mm) MODEL A B 245 245 245 C 270 270 270 D 300 300 300 E 230 230 230
WEIGHT (Kg) 5,6 5,6 5,6
ED 1 T ED 1,5 T ED 2,5 T
350 350 350
DAB PUMPS reserve the right to make modifications without prior notice
45
ED 4 T - ED 7,5 T - ED 8 T - ED 15 T - ED 20 T - ED 25 T - ED 30 T GENERAL DATAApplicationsElectrical panels for protection and automatic control using float/s for submersible three-phase electric pumps, installed singly, as shown in the following table:CONTROL PANEL ELECTROPUMP FEKA 3000.4 T FEKA 3000.2 T, FEKA 3500.2 T, FEKA 3700.2 T FEKA 6075.6 T FEKA 4000.4 T FEKA 4100.4 T, FEKA 4100.2 T, FEKA 4150.2 T, FEKA 6100.6 T, FEKA 6120.4 T FEKA 4125.2 T, FEKA 4200.2 T, FEKA 6150.4 T FEKA 6250.4 T, FEKA 6200.4 T FEKA 6300.4 T
CharacteristicsSupplied with cabinet in flame-proof, thermoplastic material, with brackets for wall-mounting. The panel is self-protected and protects the electric pump from overloading and short circuits, power failure with a manually resettable device. Supplied complete with: - isolator for the power input line with padlockable door handle; - self-protected transformer for 24V powering of external commands; - terminals for connecting electric pump and min. and max. control float/s (or pressure switches, etc.); - terminals for connecting a remote acoustic or luminous alarm (without potential); - terminals for connecting temperature/oil sensors from the motor. Supplied with a jumper to be removed when using it. - switch on the front of the panel for man - 0 - aut operation of the electric pump; - LED on the front of the panel: - red LED indicating that the thermal-current protection device has cut in - green LED on the front of the panel indicating the pump is working - yellow LED indicating that the auxiliary circuits are working correctly - Models ED 15 T and ED 20 T are provided with star-delta starting.
TECHNICALDATA- Rated power input: - Phases: - Frequency: - Rated input current (A):
- Operating temperature range: -10C +40C - Storage temperature range: -25C + 55C - Relative humidity (without condensation): 50% at 40C MAX (90% at 20C) - Max. altitude: 3000 m (a.s.l.) - Level of protection: IP55 - The panels are built to EN 60204-1 and EN 60439-1 standards
MODEL A B 245 245 335 245 335 335 335 335 C 270 270 270 270 270 270 270 270 D 300 300 390 300 300 300 300 300 E 230 230 230 230 230 230 230 230
Y
Y Y Y Y
ED 4 T ED 7,5 T ED 7,5 T ( ED 8 T ED 15 T ( ED 20 T ( ED 25 T ( ED 30 T (
/ )
/ ) / ) / ) / )
Y
Y Y Y Y
ED 4 T ED 7,5 T ED 7,5 T ( ED 8 T ED 15 T ( ED 20 T ( ED 25 T ( ED 30 T (
/ )
/ ) / ) / ) / )
400V~ +/- 10% 3 50-60 Hz ED 4T ED 7,5 T ED 8 T ED 15 T ED 20 T ED 25 T ED 30 T 6-10 9-14 13-18 20-25 24-32 25-40 40-63
DIMENSIONS (mm)
WEIGHT (Kg) 8 10 10 10,5 16 16 18,4 18,4
350 350 350 350 350 350 350 350
46
DAB PUMPS reserve the right to make modifications without prior notice
E2D 16 T - E2D 30 T - E2D 40 T - E2D 50 T - E2D 60 T GENERAL DATAApplicationsElectrical panels for protection and automatic control using float/s for submersible three-phase electric pumps, twin installation, as shown in the following table:CONTROL PANEL ELECTROPUMP FEKA 4000.4 T
E2D 16 T E2D 30 T ( E2D 40 T ( E2D 50 T ( E2D 60 T (
CharacteristicsSupplied with cabinet in flame-proof, thermoplastic material, with brackets for wall-mounting. The panel is self-protected and protects the electric pump from overloads and short circuits with manual reset. Complete with: - modular isolator for the power input line with padlockable door handle; - self-protected transformer for 24V powering of external commands; - terminals for connecting the electric pump and min./max. control floats (or pressure switches, etc.); - terminals for connecting a remote acoustic or luminous alarm; (without potential) - terminals for connecting temperature/oil sensors from the motor. Supplied with a jumper to be removed when using it. - pre-set for inverting the starting order of the two pumps at every start up, for simultaneous operation and for starting one of the two in case the other one breaks down; - switch on the front of the panel for manual 0 automatic electric pump operation; - indicators on the front of the panel: - red LED indicating the current protection device has cut in; - green LED indicating the pump is working; - yellow LED indicating the auxiliary circuits are working properly. - Models E2D 30 T and E2D 40 T are provided with star-delta starting.
TECHNICALDATA- Rated power input: - Phases: - Frequency: - Rated input current (A):
- Operating temperature range: -10C +40C - Storage temperature range: -25C + 55C - Relative humidity (without condensation): 50% at 40C MAX (90% at 20C) - Max. altitude: 3000 m (a.s.l.) - Level of protection: IP55 - The panels are built to EN 60204-1 and EN 60439-1 standards
MODEL A B 335 335 335 335 335 C 270 270 270 270 270 D 390 390 390 390 390 E 230 230 230 230 230
E2D 16 T E2D 30 T ( E2D 40 T ( E2D 50 T ( E2D 60 T (
/ ) / ) / ) / )
DAB PUMPS reserve the right to make modifications without prior notice
Y Y Y Y
/ ) / ) / ) / )
FEKA 4100.4 T, FEKA 4100.2 T, FEKA 4150.2 T, FEKA 6100.6 T, FEKA 6120.4 T FEKA 4125.2 T, FEKA 4200.2 T, FEKA 6150.4 T FEKA 6250.4 T, FEKA 6200.4 T FEKA 6300.4 T
400V~ +/- 10% 3 50-60 Hz E2D 16 T E2D 30 T 13-18 20-25
E2D 40 T 24-32
E2D 50 T 25-40
E2D 60 T 40-63
DIMENSIONS (mm)
WEIGHT (Kg) 15 15 30 37 37
345
Y Y Y Y
514 514 514 514
47
E3D 7,5 T - E3D 12 T - E3D 22,5 T - E3D 22,5 T S/D - E3D 24 T E3D 45 T S/D - E3D 60 T S/D - E3D 75 T S/D - E3D 90 T S/D GENERAL DATAApplicationsControl cabinets for protection and automatic operation by means of float switch(es) of three-phase submersible electric pumps installed in pairs as shown in the following table:PANEL ELECTRIC PUMP FEKA 2500 4.T - FEKA 2500 2.T - FEKA 2700 FEKA 3000 4.T FEKA 3000 2.T - FEKA 3500 2.T - FEKA 3700 FEKA 6075 6.T FEKA 4000 4.T FEKA 4100 4.T - FEKA 4100 2.T - FEKA 4150 2.T - FEKA 6120 FEKA 4125 2.T - FEKA 4200 2.T - FEKA 6150 FEKA 6200 4.T - FEKA 6250 4.T FEKA 6300 4.T 2.T 2.T
E3D 7,5 T E3D 12 T E3D 22,5 T E3D 22,5 T S/D E3D 24 T E3D 45 T S/D E3D 60 T S/D E3D 75 T S/D E3D 90 T S/D
4.T - FEKA 6100 6.T 4.T
Features
Supplied in a self-extinguishing thermoplastic enclosure, complete with wall mounting brackets. The control box is self-protected and it protects the pump from overloads, short circuits and phase loss, with manual reset. Complete with: - Power line disconnect device with padlockable door lock handle; - Self-protected transformer to provide 24V supply for external controls; - Terminals to connect electric pump and minimum/maximum level float switches (or pressure switches, etc.); - Terminals to connect alarm control for remote installation of a sounder or warning light (voltage free); - Terminals for connection of temperature/oil sensors from motor. Supplied with a series of jumpers