Product Datasheet March 2009 www.daniel.com Liquid Turbine Flow Meters Daniel ® Series 500 Liquid Turbine Flow Meter
Transcript

Product DatasheetMarch 2009

www.daniel.com

Liquid Turbine Flow Meters

Daniel® Series 500 Liquid Turbine Flow Meter

Product DatasheetLiquid Turbine Flow Meters

Page �

Portable, lightweight Meter with integrated electronicsDaniel Series 500 Liquid Turbine Flow Meter is a compact flow meter that serves the need for accurate flow measurement in mobile operations. The meter utilizes an aluminum/stainless steel rotor, with stainless steel ball bearings, stainless steel shaft and built-in flow conditioning plate. The internals have been proven over many years in various applications. The portable meter body is constructed of aluminum and designed with protective handles for the integral mounted intrinsically safe totalizer electronics.

The meter is incorporated with standard TTMA Flanges for easy mating of quick camlock couplers. Each meter is equipped with an inlet female coupler, sight glass, and the outlet has a �/4 turn butterfly valve and male coupler.

Daniel Series 500 Liquid Turbine Flow Meter is versatile and adds a new level of reliability to the measurement of various refined and light hydrocarbon products, including gasoline and diesel fuels.

ApplicationsTruck off-loadingMarketing terminal check metering

••

Features and benefitsLightweight design for portabilityHigh accuracy and repeatabilityIntegral mounted intrinsically safe electronics providing flow rate, reset and non-reset totalizers Battery poweredFully programmableWatertight to IP65 (NEMA 4X)TTMA flanged meter bodyAvailable in 3" and 4" line sizesSimple and easy to maintainStainless steel bearingsPassword protected totalizer settingsLimited warranty

•••

•••••••••

Daniel® Series 500 Liquid Turbine Flow Meter

Daniel® Series 500 Liquid Turbine Flow Meter

Product DatasheetLiquid Turbine Flow Meters

Page 2

Materials of ConstructionSizes 3" and 4"

Meter Body and Flanges: Aluminum (standard)Internals: Aluminum and stainless steel Bearings: Stainless steel ball bearings (standard) Flow Conditioner Plate Material: Delrin® �50 (standard) Couplers: Aluminum Site Glass: Acrylic Gaskets: Cork, Buna-N Valve: Aluminum, Viton®, Buna-N Spacer: Aluminum Flange Type: TTMA flanges standard on meter body

•••••

••••••

ShIPPInG WeIGhT AnD VoLuMeSIze

(InCh)TTMA FLAnGeD, 8 hoLe 7/16"

LBS KG Cu. FT. Cu. MeTer

3" 35 �5.9 3 0.085

4" 40 �8.� 3 0.085

Meter Performance Sizes 3" and 4"

Linearity: ± 0.25%*

repeatability: ± 0.02%*

*Under pressure condition with full line of liquid.

Process Parameters Temperature ratings

Process: 0°C to 60°C (32°F to �40°F)

Ambient: -40°C to 70°C (-40°F to �58°F)

Pressure ratings and ConnectionsMaximum Allowable Working Pressure: 75 psig

Ingress Protection ratingIP65 neMA 4X

Pick-off SpecificationsType: 2-wire reluctance resistance: 650 - 950 Ohms Inductance: 250 mH max output: Sinusoidal 40mV p-p minimum @minimum flow

••

••

••••

sPecificationsPlease consult Daniel if your requirements are outside the specifications noted below. Improved performance, other product and material offerings may be available depending on the application. For world area locations and contact information, please refer to the back page of the datasheet.

Product DatasheetLiquid Turbine Flow Meters

Page 3

DAnIeL® SerIeS 500 LIQuID TurBIne FLoW MeTer: MoDeL SeLeCTIon MATrIX T500 XX X X X X

TurBIne BASe CoDeSIze GPM BPh M3/hr LPM houSInG InTernALS

3" 65/650 93/930 �4.7/�47.6 246/2460 ALUMINUM STAINLESS STEEL / ALUMINUM ............................... 034" �00/�000 �43/�430 22.7/227.� 378/3875 ALUMINUM STAINLESS STEEL / ALUMINUM ............................... 04

eLeCTronICS oPTIonS (ALL InTeGrALLy MounTeD)DISPLAy ONLy (FLOW rATE, TOTAL VOLUME rESETTABLE, ACCUMULATED TOTAL VOLUME NON-rESETTABLE, INTrINSICALLy SAFE) A

PICK-oFF(S)ONE .............................................................................................................................................................. A

APProVALSNONE ................................................................................................................................................................. A

ACCeSSorIeSNONE ..................................................................................................................................................................... AEND CAPS FOr INLET/OUTLET ........................................................................................................................................ B

Product DatasheetLiquid Turbine Flow Meters

Page 4

Integral Mounted rate TotalizerDisplay-Digits: 7 digit �7mm (0.67”) high intensity LCD

�� digit 8mm (0.3�”) high intensity LCDK-Factor range: The pulses per unit of measure (e.g., pulses / gallon) are programmable in the range 0.0000�0 to 9,999,999.Decimal Points: Fully programmable for rate and totalTime Base: rates can be displayed in units per second, minute, hour or dayFrequency range: 0.0�Hz to 7kHzSignal Type: Coil / sine wave (minimum 20mVpp or 80mVpp - sensitivity selectable), NPN/PNP, open collector, reed switch, Namur, active pulse signals 8 -�2 and 24V DCenvironment electromagnetic Compatibility: Compliant ref: EN 6�326 (�997), EN 6�0�0-� (�993)

••

••

operating Temperature: -40°C to 70°C (-40°F to �58°F)Battery Powered

Battery Type: Lithium battery

Battery Life: 5 years

resolution: �6 bit. Error < 0.0�mA / ±0.05% FSupdate Time: Four times per secondConnections: 2 wireVoltage Drop: 2.6V DC @ 20mAMemory Backup: Lithium batteryhazardous Area: II � GD EEx ia IIC T4 T�00°CMaximum Ambient Temperature: 70°C (�58°F)

••

•••••••

Daniel® Series 500 Liquid Turbine Flow Meter Totalizer

Product DatasheetLiquid Turbine Flow Meters

Daniel® Series 500 Liquid Turbine Flow Meter

2009 Daniel Measurement and Control, Inc. All rights reserved. Unauthorized duplication in whole or in part is prohibited. Printed in the USA. DAN-LIQ-DS-500-0309

emerson Process ManagementDaniel Measurement and Control, Inc.www.daniel.com

north America / Latin America:headquartersuSA - houston, TexasT +�.7�3.467.6000F +�.7�3.827.3880USA Toll Free �.888.FLOW.00�

europe: Stirling, Scotland, uK T +44.�786.433400F +44.�786.43340�

Middle east, Africa: Dubai, uAeT +97�.4.883.5235F +97�.4.883.53�2

Asia Pacific: Singapore T +65.6777.82��F +65.6770.800�

Daniel Measurement and Control, Inc. ("Daniel") is a wholly owned subsidiary of Emerson Electric Co., and a division of Emerson Process Management. The Daniel name and logo are registered trademarks of Daniel Industries, Inc. The Emerson logo is a registered trademark and service mark of Emerson Electric Co. All other trademarks are the property of their respective companies. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by Daniel's terms and conditions which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time. Daniel does not assume responsibility for the selection, use or maintenance of any product. responsibility for proper selection, use and maintenance of any Daniel product remains solely with the purchaser and end-user. Daniel Series 500 Liquid Turbine Flow Meter is protected by U.S. and international patents and patents pending.