+ All Categories
Home > Documents > DAS Sharing Architecture

DAS Sharing Architecture

Date post: 06-Jul-2018
Category:
Upload: dattarajrf
View: 217 times
Download: 0 times
Share this document with a friend

of 7

Transcript
  • 8/17/2019 DAS Sharing Architecture

    1/7

    RJIL Small Cell

    Confidential Reliance Jio Infocomm Limited 1

  • 8/17/2019 DAS Sharing Architecture

    2/7

    Indoor Coverage Solutions

    Confidential Reliance Jio Infocomm Limited 2

    Small Cells

    • Small Cells will beinstalled for LTEservices along withseparate Wi-Fi APs

    • LTE will cover 95% ofcarpet area with -85dBm RSRP

    • 2x2 MIMO

    • Throughput of 30~40Mbps on LTE services

    DAS + Wi-Fi

    • DAS will be shared fromother ISP/Operators forLTE services

    • DAS will cater to90~95% of carpet areawith -85dBm RSRP

    • SISO

    • Throughput of 20~30Mbps on LTE services

    Small Cells with

    Wi-Fi

    • Integrated Small Cells(LTE + Wi-Fi) will beinstalled for services

    • LTE will cover 95% ofcarpet area with -85dBm RSRP

    • 2x2 MIMO

    • Throughput of 30~40Mbps on LTE serviceswith Wi-Fi for TrafficOffload.

  • 8/17/2019 DAS Sharing Architecture

    3/7

    Confidential Reliance Jio Infocomm Limited 3

    Indoor Small Cells  – Architecture Diagram

    CSS

    FTB

    Switch

    SMPS+Inverter

    +(AC+DC) PDU

    Battery

    Battery

    Battery

    FTB

    PDU

       L   o   w   e   r   G   n    d

       G   n    d   F    l   o   o   r

       1

       s   t     F    l   o   o   r

       3   n    d    F

        l   o

       o   r

    Hybrid Cable

    Hybrid Cable

    Hybrid Cable’s 

       O   p   t   i   c   a    l   F   i    b   r   e

       P   o   w   e   r   C   a    b    l   e

       O   p   t   i   c   a    l   F   i    b   r   e   B   a

       c    k    h   a   u    l

       E    l   e   c   t   r   i   c   a    l   I   n   p   u   t

    Backhaul over Microwave

    Distribution Unit

  • 8/17/2019 DAS Sharing Architecture

    4/7

    Confidential Reliance Jio Infocomm Limited 4

    Indoor Small Cells - Specifications

       A   i   r   S   y   n   e   r   g   y   1   0   0   0

    • Power

    Consumption:80W (Peak Load)

    • Dimension:530X144X206 mm

    • Weight: 12 Kg

    • Input Power: 230VA/C

    • IP66 Compliant`

       A   i   r   V   e    l   o   c   i   t   y

    • Power

    Consumption:60W (Peak Load)

    • Dimension:45X22X16 mm

    • Weight: 4 Kg

    • Input Power: 230VA/C

    • IP44 Compliant

  • 8/17/2019 DAS Sharing Architecture

    5/7

    Confidential Reliance Jio Infocomm Limited 5

    DAS Sharing  – Architecture Diagram (Option 1)

    CSS

    FTB

    BBU

    SMPS

    +(AC+DC) PDU

    Battery

    Battery    L   o   w   e   r   G   n    d

       G   n    d   F    l   o   o   r

       1

       s   t     F    l   o   o   r

       3   n    d    F

        l   o

       o   r

    Hybrid Cable’s 

       O   p   t   i   c   a    l   F   i    b   r   e   B   a

       c    k    h   a   u    l

       E    l   e   c   t   r   i   c   a    l   I   n   p   u   t

    Sector 3

    Sector 2

    Sector 1

  • 8/17/2019 DAS Sharing Architecture

    6/7

    Confidential Reliance Jio Infocomm Limited 6

    DAS Sharing  – Architecture Diagram (Option 2)

    CSS

    FTB

    BBU

    SMPS

    +

    (AC+DC) PDU

    Battery

    Battery    L   o   w   e   r   G   n    d

       t   o

       G   n    d   F    l   o   o   r

       G   n    d

       t   o

       2   n    d    F

        l   o   o   r

       3   r    d    t   o

       6   t    h    F

        l   o   o   r

       7   t    h    t

       o   1   0   t    h    F

        l   o   o   r

       O   p   t   i   c   a    l   F   i    b   r   e   B   a   c    k    h   a   u    l

       E    l   e   c   t   r   i   c   a    l   I   n   p   u   t

    Sector 3

    Sector 2

    Sector 1

  • 8/17/2019 DAS Sharing Architecture

    7/7

    Indoor OSP Engineering-Rack Design

    Confidential Reliance Jio Infocomm Limited 7

    20 Small Cells

    Equipment Rack Space

    Single Door Rack

    CSS 1 U

    Switch 4 U

    FDP/LIU 1 U

    Power System 9U

    PDU 2 U

    Battery’s  7 U

    TOTAL 24 U

    Distribution Unit

    FDP/LIU 1 U

    PDU 2 UTOTAL 3 U

    Single Rack will be centrally placed, which will act as a Backhaul termination and

    Power Bank

    A number of Distribution Units will be used for providing Power & Connectivity from

    the central source to the far-off Small Cells.


Recommended