1 Data Center Facility Study
Transcript
Page 1: Data Center Facility Study

1

Data Center Facility Study

Page 2: Data Center Facility Study

2Mapping

Page 3: Data Center Facility Study

3Purposes

IT/ telecom company centers

Storage service providers

Industry/ commercial in house

Page 4: Data Center Facility Study

4Priorities

•Degrees of downtime•Center tiers

Business Continuity

•Power Use Effectiveness•Total consumption

Energy Efficiency

•Physical•CyberSecurity

Page 5: Data Center Facility Study

5Data

Climatic•Temperature

•Humidity

•Pressure

Electric•Power

•Current

•Power Factor…

IT•Data Speed

•Storage

Page 6: Data Center Facility Study

6Equipment Data

Servers

• Electric Data through Power Distribution Unit (PDU)

• Climatic data through sensor at rack/server intake (and exhaust)

HVAC / Climate Control

• Electric data metering

• Temperature, humidity and possibly pressure

Page 7: Data Center Facility Study

7Power equipment

• Input and output voltage and current, losses• Power• Harmonics

UPS

• Power (charging and discharging)• Energy storedBattery

• Generation – power and quality• UsageDG

• Power input/ output, Losses• Grid power qualityTransformer

Page 8: Data Center Facility Study

8Metering Overview: Power

• Servers

• Power Equipment monitoring

• Load monitoring: IT and HVAC (+lighting)

• Network monitoring (harmonics: active filters, ballasts)

Page 9: Data Center Facility Study

9Metering Overview: Climate

Page 10: Data Center Facility Study

10Process

Understanding:

- Smart Sense- Data

Centers

Referring to Foundry Case Study

Identifying Value of

Ecolibrium

Page 11: Data Center Facility Study

11

Proposition

Page 12: Data Center Facility Study

12Main Points

• Active PUE Monitoring and Optimization

• Asset Health Monitoring

• Reducing Redundancy through Asset Optimization

• Power Source Optimization

• Predictive Maintenance

• Modularity Integration and Scalability

Page 13: Data Center Facility Study

13Operational Efficiency

• Climate Monitoring and Asset Optimization

• Thermal zone mapping (and fluid flow analysis) for optimal equipment placement

• Minimizing losses

• Server performance monitoring

Page 14: Data Center Facility Study

14Asset Health and Predictive Maintenance

• HVAC health through motor, chiller and other asset analysis

• Battery health

• Transformer health

• UPS Health

• Active monitoring provides insight for when tests are needed

Page 15: Data Center Facility Study

15Redundancy

Reducing CapEx by optimizing assets

and assuring reliability

- Lower value of assets and

predictive because of redundancy- Certification

requiring redundancy

Page 16: Data Center Facility Study

16Power Sourcing and Billing Insights

• Power source optimization including DERs

• Contract demand optimization

• Energy Trading from Open Access Feasibility and Bid optimization

• TOD optimization

• Incoming Voltage check

• Power factor optimization

Page 17: Data Center Facility Study

17Modularity Integration and Scalability

• Modular integration allows scalability of Ecolibrium in given data center

• Challenge is: They are very advanced and one product so difficult to integrates

Page 18: Data Center Facility Study

18Data Center Infrastructure Management

• Several discussed features exist

• Analytics is doubtful

• Use, especially in India is sparse (instead use SCADA/ BMS)

• IT Data centers vs facility supporting data centers

Page 19: Data Center Facility Study

19Data Center Certification

TIA 942

Page 20: Data Center Facility Study

20

Page 21: Data Center Facility Study

21Infibeam Meeting

• Meeting with a very experienced person in the industry, in charge of designing Infibeam’s next data center at GIFT city

His opinion:

• What we are proposing already exists (including analytics) and done by big companies

• Can’t reduce redundancy because it is needed for certification

• Look at data centers of people who’s core business isn’t data centers (industry, hospital, etc.)

• Modular data centers have company integrted monitoring

• Infibeam (first in India) getting Lithium Ion batteries instead of VRLA

Page 22: Data Center Facility Study

22GIFT city visit

• Supposedly very advanced for India, “only Tier 4 data center in India”

• Manual readings (LT, HT, etc.) – Schneider equipment with integrated panels

• Redundancy in everything – needed for certification

• BMS used for monitoring – extremely limited

Page 23: Data Center Facility Study

23Creating a world where every watt counts!