When every minute counts, choose the solution that makes a difference.
V I C T A U L I C • P I P I N G S O L U T I O N S F O R D A T A C E N T E R F A C I L I T I E S
2 Data Centers www.victaulic.com
As the world leader in mechanical piping systems, Victaulic
has set the global standard for piping efficiency, engineering
expertise and performance reliability by protecting, heating
and cooling buildings all over the world.
Hoover Dam - United States
• Supplies 16 million people with water every day
• Generates 4 billion kilowatt hours of hydroelectric energy annually
• Outfitted with Victaulic mechanical piping products because they installed quickly and easily with only minimal service disruptions
From performing under pressure in the Hoover Dam to protecting
ancient treasures in Egypt, Victaulic has been trusted for 85
years to provide quality products that meet the most demanding
industry challenges.
Alexandria Library - Egypt
• Home to priceless ancient artifacts from around the world
• The Library required unparalleled piping system reliability
• Victaulic products for both HVAC and Fire Protection systems were trusted throughout the building
Victaulic PIPING. SYSTEMS. SOLUTIONS.
2 Data Centers
Trust Victaulic to protect and cool your mission critical facilities.
As more and more data centers transition to water systems as the most efficient method of cooling - 4,000 times more efficient than air - owners and engineers demand only the most reliable piping systems are used in their facilities.
Whether cooling, heating or protecting your data center facility, Victaulic has the products and solutions to get your data center up and running quickly and operating efficiently.
Data Centers 3
4 Data Centers www.victaulic.com
Compressed Project SchedulesVictaulic mechanical piping systems are three to five times faster to
install than traditional joining methods. Meet and exceed the “flash-
track” schedules associated with data center construction.
Victaulic benefits that save you time and valuable resources.
IMPROVED SAFETYNo flame joining method
LABOR SAVINGSEasier maintenance and system expansion
DESIGN VERSATILITYMore options and easily accomodates system change
3
1
2
6
5
4
9
10
11
8
7
12
MA
N H
OU
RS
PER
JO
INT
PIPE SIZE
Grooved
Welded
Flanged
2" 4" 6" 8" 10" 12"
Quicker, easier installations
3 TO 5 TIMES FASTER TO INSTALL
4 Data Centers
Welded systems demand 45% more man-hours on average compared
to Victaulic no-flame piping solutions.
The math is simple: less man-hours equals less exposure and project risk.
Victaulic will increase project
efficiency and reduce field
man-hours from start to finish
with value added services.
VICTAULIC SERVICES
INCLUDE:
• Estimating
• Pre-Planning and Project
Management
• Jobsite Training
• Software Solutions
NU
MBE
R OF
MEN
ON
SIT
E
MECHANICAL CONSTRUCTION WEEKS
Shift Maximum Manpower Line
Meet or Beat Project Schedule
Victaulic Peak Man-Power
Welded Peak Man-Power
Data Centers 5
6 Data Centers www.victaulic.com
Seismic Performance TestingNatural disasters happen, but when there
is no time for downtime, planning ahead
can make a world of difference.
Piping systems located in earthquake prone
areas are likely to be exposed to forces and
deflections beyond normal static conditions
and the results can be catastrophic.
Victaulic components can accommodate seismic forces in the following piping system conditions.
• Code-regulated systems with adequate earthquake bracing
• Unregulated systems with little or no earthquake bracing
• Seismic joint connections between independently-moving sections
• Buried systems
Seismic swing joint utilizing Victaulic mechanical piping components
6 Data Centers
Testing performed at the Real-Time Multi-directional Experimental Laboratory at the Center
for Advanced Technology for Large Structural Systems at Lehigh University in Bethlehem, PA,
USA proved the suitability of Victaulic grooved mechanical couplings to maintain operational
integrity of piping systems during seismic events.
Victaulic couplings ranging in size from
4”-16”/100 - 400 mm were exposed to
accelerations up to 50% greater than the
Northridge, California earthquake. The
water-filled assemblies were pressurized to
200psi/1375 kPa for the duration of all tests
and no pressure loss or leakage was noted
during any of the tests.
Data Centers 7
8 Data Centers www.victaulic.com
The versatility, reliability and speed of Victaulic mechanical pipe
joining systems makes them ideal for use in data center applications.
By specifying and installing Victaulic, engineers, owners and installation contractors conserve time and financial resources through:
COMPRESSED PROJECT SCHEDULES Victaulic systems increase project efficiency from the start
LOWERED TOTAL INSTALLED COST Over the lifetime of the system
SAFER WORK ENVIRONMENT Reduced calendar days reduces exposure to job site accidents
REDUCED SYSTEM DOWNTIME during scheduled maintenance and service checks
Anatomy of a Grooved Joint
8 Data Centers
Contraction
Expansion Deflection
A UNION AT EVERY JOINTRemoval of two couplings permits removal of a pipe section for replacement, cleaning or servicing.
MAINTAINABILITY
Victaulic systems provide easy accessibility when conducting preventative systems maintenance, resulting in a continued high level of energy efficiency and little to no downtime required.
Maintenance plans are a critical element to every data center. Whether maintaining computer equipment or cooling equipment, system shut downs are limited to mere minutes. By using Victaulic mechanical piping systems, changing out inefficient equipment is as easy as loosening two bolts and two nuts. There is no need and no time required to cut out sections of pipe and re-weld.
Exaggerated for clarity
VALUE ADDED ENGINEERING
At the root of all the benefits
that Victaulic solutions bring
to a project - such as jobsite
productivity, safety, design
flexibility and quality - are the
unique features of its products.
Roll Grooving
Expansion & Contraction
Coupling Assembly
Deflection Capabilities
Data Centers 9
10 Data Centers www.victaulic.com
Condenser Water Units
To get your data center up and running
quickly, Victaulic offers a full line of
couplings, fittings, valves and accessories for
use throughout a facility’s mechanical room.
1ST FLOOR MECHANICAL ROOM
Mechanical Room Piping
End Suction Pumps
Data Center Mechanical Room
10 Data Centers
Chillers
Horizontal Split Case Pump
From pumps and chillers to air handling units
and cooling towers, Victaulic mechanical
piping systems provide a fast, safe, reliable
connection ideal for data center applications.
i S i
Data Centers 11
12 Data Centers www.victaulic.com
Data Center Distribution Piping
DN
.
CH
ASE
BOM 7
BOM 9
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit CRAC Unit
CRAC Unit
CRAC Unit
Future CRAC Unit
CRAC Unit CRAC Unit
CRAC Unit
Future CRAC Unit
Victaulic products are ideal for use in data center distribution piping
because they install quickly and easily, provide a safe, reliable pipe
connection and easily accommodates tight space constraints.
2ND FLOOR DATA CENTER
Victaulic couplings and fittings
are ideal for use in tight spaces
Victaulic rigid couplings for
straight runs of pipe
Branch connections made easy
using Victaulic products
i i i fi i
Vi li i id li f
B h ti d
12 Data Centers
DN
.
DN.
MECH.CHASE
MECH.CHASE
FM-2
00 C
HAS
E BE
LOW
ELECT. CHASE BELOW
1'-111516"
CRAC Unit
CRAC Unit CRAC Unit CRAC Unit
CRAC Unit
CRAC Unit CRAC Unit CRAC Unit CRAC Unit
CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Futu
re C
RAC
Uni
tFu
ture
CRA
C U
nit
Futu
re C
RAC
Uni
t
Futu
re C
RAC
Uni
tFu
ture
CRA
C U
nit
CRAC Unit
Victaulic butterfly valves for
dead-end shutoff
Victaulic offers a full line of
piping systems components
Victaulic couplings
and elbows
Mechanical Room Connection to Second Floor Distribution Piping (Under-floor piping)
Vi li li
Vi t li b tt fl l f
Data Centers 13
14 Data Centers www.victaulic.com
Protecting Equipment, Personnel and the Environment
Until now, fire suppression meant
damaged equipment, lengthy and
costly clean up, and lost productivity.
Now, data center owners can breathe
a little easier knowing their equipment
and environment are protected by
the VictaulicVortex Fire Suppression
System.
VictaulicVortex
• The only hybrid nitrogen-water fire
suppression system
• Nearly ZERO wetting of protected areas
• No ozone depleting or greenhouse
gas emissions
• Quick system recharge to support
minimal facility downtime
“ My clients were very impressed with
the VictaulicVortex system when they
saw the level of fire protection it provides
without huge amounts of water or toxic
chemicals. It’s all about protecting the
people and assets, minimal impact on
the hazard environment and the fast
return to normal operations.
The Vortex system delivers.”
TOM EUSON, 3S INCORPORATED
Made entirely of non-toxic agents — personnel are safe even during activation; reduction of oxygen in the space is at levels within safe breathing tolerances.
System activation is immediate when sensors detect smoke or heat — there is no delay in activation to evacuate personnel to avoid a toxic environment.
VictaulicVortex™ Fire Suppression
14 Data Centers
VictaulicVortex in a Data Center
The system fully
extinguishes fires in
enclosed cabinets and
isolated equipment within
protected spaces.
Zones can be
centrally controlled yet
independently activated
for fire suppression only
where required.
The system delivers
as little as one gallon
of water per emitter
per minute: each
emitter can protect
up to 2,500 cubic ft.
The system is
compatible with facility
fire protection systems
providing greater
design flexibility.
System is recharged
rapidly allowing for
a return to working
conditions almost
immediately after
a fire.
Data Centers 15
16 Data Centers www.victaulic.com
Global Data Center Project SuccessesFrom the United States to Singapore, Victaulic mechanical
piping systems are trusted all over the world to protect, heat
and cool data centers.
16 Data Centers
www.victaulic.com
The Victaulic website is an information resource
that can help you with your piping projects.
Among the many resources available at the site:
• Fully searchable product and project databases • Free product submittals • Free product literature • Piping software demos, modules and downloads. • Information on new product innovations • Support services, and more...
VICTAULIC LOCATIONS
MB-110 5442 Rev.C
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.
© 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
VICTAULIC
BELGIUM
(EUROPE HEADQUARTERS)
Prijkelstraat 36
B9810 Nazareth (Belgium)
tel. +32 93 81 1500
fax +32 93 80 4438
UNITED ARAB EMIRATES
P.O. Box 17683
Jebel Ali
Dubai
(United Arab Emirates)
tel. +971 48 838 870
fax +971 48 838 860
UNITED KINGDOM
Units B1 & B2, SG1 Industrial Park
Cockerell Close
Gunnels Wood Road, Stevenage
Hertfordshire SG1 2NB (UK)
tel. +44 (0) 143 831 0690
fax +44 (0) 143 831 0699
INDIA
Victaulic Piping Products
India Priv. Ltd.
Indialand Global Industrial Park
Plot 4, Hinjewadi, Phase I, Mulshi
Pune 411057 (India)
tel. +91 20 67 919 300
fax +91 20 67 919 361
SPAIN
Autovia Madrid-Barcelona
KM 45,000
Avda. De Milan 18
19200 Azuqueca De Henares
(Spain)
tel. +34 949 348 490
fax +34 949 266 848
UNITED STATES
(WORLD HEADQUARTERS)
PO Box 31
4901 Kesslersville Road
Easton, PA 18044-0031 (USA)
tel. +1 610 559 3300
fax +1 610 250 8817
CANADA
123 Newkirk Road
Richmond Hill, ON L4C 3G5
(Canada)
tel. +1 905 884 7444
fax +1 905 884 9774
ASIA
Unit 808, Building B
Hongwell Plaza
No.1602 West Zhongshan Road
Shanghai, China 200235
tel. +86 21 6021 9400
fax +86 21 6021 9500
www.victaulic.com
ITALY
Via M. Biagi 23/25/27
27022 Casorate Primo
(Italy)
tel. +39 02 900 58 256
fax +39 02 900 58 292
GERMANY
LOGICPARK
Gutenbergstraße 19
D-64331 Weiterstadt
(Germany)
tel. +49 (0) 6151 9573 - 0
fax +49 (0) 6151 9573 - 150