+ All Categories
Home > Documents > Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb...

Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb...

Date post: 04-Jan-2016
Category:
Upload: willis-riley
View: 224 times
Download: 0 times
Share this document with a friend
14
Data reliability on Data reliability on optical discs optical discs Mladen Tušek Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Filozofski fakultet, Ivana Lučića 3, Zagreb Zagreb Hrvatska Hrvatska [email protected] [email protected]
Transcript
Page 1: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.

Data reliability on optical Data reliability on optical discsdiscs

Mladen TušekMladen TušekFilozofski fakultet, Ivana Lučića 3, ZagrebFilozofski fakultet, Ivana Lučića 3, Zagreb

Hrvatska [email protected]@yahoo.com

Page 2: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.

IntroductionIntroduction

Optical discs suitable for preserving data:

• CD 650 or 700 MB• DVD 4,7 or 9 GB• HD DVD 15 or 30 GB• Blu-Ray 25 or 50 GB

Page 3: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.
Page 4: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.

Long term data Long term data preservation on optical preservation on optical

discsdiscs• Physical damage• Chemical damage

-chemical layer “Phthalocyanine”

-reflexive gold layer

Page 5: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.

IdentificationIdentification of media of media

• Identification of disc manufacturer• Identification of chemical layer• Other relevant information about optical disc

Page 6: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.
Page 7: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.
Page 8: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.

AnalysisAnalysis and and data recoverydata recovery

• Disc reading speed as indication of data status on discs chemical layer

• Aging of chemical layer causing data loss on all optical discs of the same manufacturer

• Unequal quality of chemical layer causes data loss on one or more optical discs

Page 9: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.
Page 10: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.
Page 11: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.
Page 12: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.

ConclusionConclusion

• Using quality discs, two of them with different chemical layer and manufacturer

• Parallel data writing on two computers with two different data recorders (different manufacturers: Plextor and Pioneer, for example).

• Low speed recording (4x) and mandatory data verification after recording

• After data recording test readability of recorded disc in different optical devices

Page 13: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.

• After one recording session and before erasing source data make readability test

• During archiving process in regular intervals (every 6 months) check readability using random method

• In case of problem use specialized applications and copy content of optical disc before irreversible data loss occur

Page 14: Data reliability on optical discs Mladen Tušek Filozofski fakultet, Ivana Lučića 3, Zagreb Hrvatska mladentusek@yahoo.com mladentusek@yahoo.com.

Thank YouThank You


Recommended