Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document Updates JAMES THURMAN & NEALSON WATKINS OFFICE OF AIR QUALITY PLANNING & STANDARDS APRIL 2016
Transcript
Page 1: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Data Requirements Rule for the 1-hour SO2 NAAQS:

Overview &

Technical Assistance DocumentUpdates

J A M E S T H U R M A N & N E A L S O N W AT K I N S

O F F I C E O F A I R Q U A L I T Y P L A N N I N G & S TA N D A R D S

A P R I L 2 0 1 6

Page 2: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Data Requirements Rule (DRR) –Overview

Final rule signed August 10, 2015 (http://www3.epa.gov/airquality/sulfurdioxide/implement.html)

Because the existing SO2 monitoring network impacts a limited set of areas, DRR directs States and Tribes to characterize air quality in areas with large SO2 sources greater than 2,000 TPY using most recent data Directs agencies to either establish ambient monitoring sites or conduct air

quality modeling to characterize air quality

Data can be used for additional designations and implementation purposes

Alternatively, an agency can establish a federally enforceable emission limit for sources to remain below 2,000 TPY and avoid the air quality characterization requirement

2

Page 3: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Timeline for DRR

August 2015: final DRR

January 15, 2016 – states submit list of sources that emitted at least 2,000 TPY per most recent data and are not citing new monitors by January 2017 States and EPA retain discretion to require sources emitting less than 2,000 TPY to

characterize air quality

July 1 2016 – for each of the listed sources, states indicate whether they will monitor, model, or establish a limit Modeling protocols due for sources to be modeled, new monitoring plans for those to be

monitored, and any descriptions of planned emission limits

January 2017 New monitoring sites must be operational by January 1, 2017

Modeling analyses must be submitted to EPA by January 13, 2017

Documentation of federally enforceable limits and compliance submitted by January 13, 2017; note also that a shutdown has to be documented and occur prior to Jan. 13, 2017

May 2020 – certification of 2019 monitoring data; 2017-2019 design values can be calculated

3

Page 4: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Monitoring and Modeling Technical Assistance Documents

Monitoring TAD

◦ Describes analytical approaches to help cite monitoring locations to characterize peak SO2 concentrations around a source

◦ Approaches include modeling, exploratory monitoring, and weight of evidence

Modeling TAD

◦ Recommends modeling approaches to characterize air quality

◦ Includes consideration of nearby sources, meteorological data, background concentrations and other key modeling parameters

Links

http://www3.epa.gov/airquality/sulfurdioxide/pdfs/SO2MonitoringTAD.pdf

http://www3.epa.gov/airquality/sulfurdioxide/pdfs/SO2ModelingTAD.pdf

4

Page 5: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

TADs historyInitial draft TADs released May 2013

Revised versions released December 2013 based on comments received on May draft

Revised February 2016 based on comments on DRR proposal and questions from stakeholders◦ Updated text to reflect DRR is final◦ Specific to modeling TAD

◦ Added text about the Appendix W proposal and use of AERMOD beta options◦ Receptor strategy of placing receptors in areas that can be monitored is done with actual

or allowable emissions◦ Section added discussing mixing emissions of different time periods

◦ Specific to monitoring TAD◦ The TAD language now reflects the EPA's strong preference that any modeling used in the

monitoring siting process be dispersion modeling

5

Page 6: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Recommendations

Model selection

Modeling domain and receptors

Sources to explicitly model vs. background

Source characterization

Emissions inputs◦ Calculation of temporally varying emissions (most recent 3 years)

◦ Discussion of mixing emissions from different time periods

◦ Allowables

4/13/2016 U.S. ENVIRONMENTAL PROTECTION AGENCY 6

Page 7: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Recommendations (cont.)

Meteorological inputs◦ 3 years of most recent data

◦ Provisions for older data

Background concentrations

Documentation

Appendices with examples

4/13/2016 U.S. ENVIRONMENTAL PROTECTION AGENCY 7

Page 8: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Designations modeling vs. SIP and PSD modeling

Parameter SIP/PSD Designations

Emissions Allowables Most recent 3 years of actual temporally varying or allowables

Stack heights GEP policy Actual heights with actual emissions; GEP policy with allowables

Meteorology 5 years NWS; at least1-year site-specific

Most recent 3 years NWS or site-specific data (concurrent with emissions); provisions for use of older data

Receptors Ambient air Ambient air where monitors could be placed

4/13/2016 U.S. ENVIRONMENTAL PROTECTION AGENCY 8

Page 9: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

4/13/2016 U.S. ENVIRONMENTAL PROTECTION AGENCY 9

SIP receptors

Page 10: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

4/13/2016 U.S. ENVIRONMENTAL PROTECTION AGENCY 10

Designations receptors

Page 11: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Data Requirements Rule Monitoring TAD

Describes analytical approaches to help cite monitoring locations to characterize peak SO2 concentrations around a source

◦ Modeling per modeling TAD but using normalized emissions

◦ Focus on identifying top receptors in terms of expected peak concentrations and frequency of occurrence

◦ Exploratory monitoring

◦ Examples include the use of FRMs, passive samples, and potentially sensors

◦ Weight of evidence

◦ Describes using existing data to build a rationale for a network design

4/13/2016 U.S. ENVIRONMENTAL PROTECTION AGENCY 11

Page 12: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

DRR Monitoring FAQ’sCan one monitor be sufficient in a network? Yes, in certain situations one monitor can be enough, but states need to

demonstrate that the one site is at or near the area(s) of expected maximum concentration

Issues to consider: emissions characteristics, topography, meteorology, other nearby sources

Can my current SO2 network be judged adequate without modification? There must be documentation to show siting at maximum concentration

location(s). Since source emission profiles that initially influenced network design may have changed over time, the EPA will expect states to describe WHY their current site location are appropriate to characterize maximum concentrations

This is explained further in the monitoring TAD

12

Page 13: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

DRR Monitoring FAQ’s (cont.)Can industrial monitors be used to satisfy the DRR? The monitor needs to be “SLAMS-like” in its operation in order to satisfy the DRR

The state is still the responsible party for ensuring data are handled, reported and certified (per 40 CFR Part 58) like SLAMS data, and that the monitor meets requirements described in Part 58 Appendices A (QA), C (methods), and E (siting)

Site(s) must be: Sited appropriately in ambient air

Utilize an approved FRM/FEM

Operate under an approved QAPP (can be the state/local’s)

Subjected to routine QA/QC (including audits)

Meet applicable siting/spacing requirements

PQAO We are recommending states strongly consider pulling industrial monitors into their own PQAO

13

Page 14: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Monitoring PerspectiveThe DRR monitoring timeline is aggressive on network deployment

SO2 monitoring is relatively simple Robust methods and hardware

QA/QC easily automated

Shelter requirements are minimal

Network siting strategies have been around for decades with respect to hunting maximum concentration locations

Long history of industrial monitoring in the US

Frameworks exist for state to use 3rd party monitoring

14

Page 15: Data Requirements Rule for the 1-hour SO NAAQS: Overview ... rev_CENSARA - SO2 TADs - A… · Data Requirements Rule for the 1-hour SO 2 NAAQS: Overview & Technical Assistance Document

Questions?For more information

SO2 NAAQS Implementation Website: http://www3.epa.gov/airquality/sulfurdioxide/implement.html