2 DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coils
for industrial valves
Contents Coil type Enclosure Power consumption Pageac dc
A-series, 9 mm system
AB IP00, IP65 4.5 W 5 W 3AC IP00, IP65 7 W 10 W 4AK IP00 3 W 5AL IP00 4 W 6AM IP00 7.5 W 9.5 W 7AR (EEx mIIT4) IP65 6 W 4.8/7 W 8
B-series, 13.5 mm system
BA IP00, IP20, IP65 9 W 15W 9BD IP00, IP20, IP65 15W 9BB IP00, IP20, IP65 10 W 18 W 10BE IP67 10 W 18 W 11BG IP67 12 W 20 W 12BN (hum-free) IP67 20 W 13BO (EEx mIIT4) IP67 10 W 10 W 14BP (EEx mIIT4) IP67 16 W 15
Compatibility
X = typical choice• = optional choice for
specific applications
2/2-way Compact AB AC AK AL AM AR
EV210A X1) X1) X1) X X •EV220A X X X X X •EV220A with filter X X
Valves for distinct purposes
EV215B / EV225B See specific datasheetEVSIS (UL approved) See specific datasheetEV260B See specific datasheet
2/2-way High Performance BA BD BB BE BG BN BO BP
EV210B X X X X X • • •EV212B X X X X • • • •EV220B 6-22 X X X X X • • •EV220B 15-50 X X X X X • • •EV220B 65-100 X X X X • • •EV222B X X • • • •EVI-U / EVSI-U See datasheet DKACV.PD.200.GEV250B X X X X • • •
Solenoid valve type Coil type
3/2-way Compact AB AC AK AL AM AR
EV310A X2) X X2) X X •
3/2-way High Performance BA BD BB BE BG BN BO BP
EV310B X X • •
1) NC versions only2) NO versions only
3DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coils type AB
4.5 W ac5 W dc
Technical data Design In accordance with VDE 0580
Voltage tolerance ± 10%
Power consumption. cut-in ac: 9.5 VA
Power consumption. holding ac: 6.3 VA. 4.5 W / dc: 5 W
Insulation of coil windings Class H according to IEC 85
Connection Spade connectors, 6.3 x 0.8 mm
Enclosure, IEC 529 IP 00 with spade connector; IP 65 with cable plug
Ambient temperature Max. +50°C
Duty rating Continuous
• Compact• Windings of class H insulated wire moulded
in the coil body• Ambient temperature: Up to +50°C• All usual ac and dc voltages• IP 00 version with 6.3 x 0.8 mm spade
connectors• IP 65 version with mounted cable plug
Features
Ordering
Symbol Description Enclosure grade Code no.
Cable plugfor 6.3 x 0.8 mm IP 65 042N0139
spade connectors
Dimensions and weight
L
Without cable plug 40 mm
With cable plug 56 mmWeight: 0.05 kg
Coil Supply Code no.type voltage IP 00
AB024C 24 V, 50/60 Hz 042N0802
4.5 W acAB110C 110 V, 50/60 Hz 042N0804
AB230C 220-230 V, 50/60 Hz 042N0800
AB240C 240 V, 50/60 Hz 042N0801
AB012D 12 V 042N08065 W dc AB024D 24 V 042N0803
Contact Danfoss for delivery of coils for other voltages
4 DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coils type AC
7.0 W ac10 W dc
Technical data Design In accordance with VDE 0580
Voltage tolerance ± 10%
Power consumption. cut-in ac: 15.7 VA
Power consumption. holding ac: 10 VA. 7 W / dc: 10 W
Insulation of coil windings Class H according to IEC 85
Connection Spade connectors, 6.3 x 0.8 mm
Enclosure, IEC 529 IP 00 with spade connector; IP 65 with cable plug
Ambient temperature Max. +50°C
Duty rating Continuous
Features • Compact• Windings of class H insulated wire moulded
in the coil body• Ambient temperature: Up to +50°C• IP 00 version with 6.3 x 0.8 mm spade
connectors• IP 65 version with mounted cable plug
Ordering Coil Supply Code no.type voltage IP 00
AC024C 24 V, 50/60 Hz 042N0823
7 W acAC110C 110 V, 50/60 Hz 042N0825
AC230C 220 - 230 V, 50/60 Hz 042N0821
AC240C 240 V, 50/60 Hz 042N0822
AC012D 12 V 042N082610 W dc AC024D 24 V 042N0824
Contact Danfoss for delivery of coils for other voltages
Symbol Description Enclosure grade Code no.
Cable plugfor 6.3 x 0.8 mm IP 65 042N0139
spade connectors
Dimensions and weight
L
Without cable plug 40 mm
With cable plug 56 mmWeight: 0.05 kg
5DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Symbol Description Enclosure grade Code no.
Protective cap IP 20 018Z0282(pack of 100 pcs.)
Cable plug according to IP 65 042N0156
DIN 43650-A Pg 11
Coils type AK
3.0 W dc
• Compact• Windings of class H insulated wire moulded
in the coil body• Ambient temperature: Up to +50°C• Power consumption: Only 3 W dc• IP 00 version with spade connector in
accordance with DIN 43650, form A• IP 20 version with protective cap• IP 65 version with mounted cable plug
Technical data Design In accordance with VDE 0580
Voltage tolerance ± 10%
Power consumption, holding dc: 3 W
Insulation of coil windings Class H according to IEC 85
Connection Spade connector in accordance with DIN 43650 form A
Enclosure, IEC 529 IP 00: Spade connector; IP 20: Protective cap; IP 65: Cable plug
Ambient temperature Max. +50°C
Duty rating Continuous
Features
Ordering
Dimensions and weight
L
Without cable plug 48 mm
With protective cap 64 mm
With cable plug 72 mmWeight: 0.10 kg
Coil Supply Code no.type voltage IP 00
3 W dc AK024D 24 V 042N0844
Contact Danfoss for delivery of coils for other voltages
6 DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Design In accordance with VDE 0580
Voltage tolerance ± 10%
Power consumption cut-in 10 VA
Power consumption, holding ac: 4 W
Insulation of coil windings Class H according to IEC 85
Connection Spade connector in accordance with DIN 43650 form A
Enclosure, IEC 529 IP 00: Spade connector; IP 20: Protective cap; IP 65: Cable plug
Ambient temperature Max. +50°C
Duty rating Continuous
Symbol Description Enclosure grade Code no.
Protective cap IP 20 018Z0282(pack of 100 pcs.)
Cable plug according to IP 65 042N0156
DIN 43650-A Pg 11
Coils type AL
4.0 W ac
• Compact• Windings of class H insulated wire moulded
in the coil body• Ambient temperature: Up to +50°C• Power consumption: Only 4 W ac• IP 00 version with spade connector in
accordance with DIN 43650, form A• IP 20 version with protective cap• IP 65 version with mounted cable plug
Technical data
Features
Ordering
Dimensions and weight
L
Without cable plug 48 mm
With protective cap 64 mm
With cable plug 72 mmWeight: 0.10 kg
Coil Supply Code no.type voltage IP 00
4 W ac AL230C 230 V ac, 50/60 Hz 042N0864
Contact Danfoss for delivery of coils for other voltages
7DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Symbol Description Enclosure grade Code no.
Protective cap IP 20 018Z0282(pack of 100 pcs.)
Cable plug according to IP 65 042N0156
DIN 43650-A Pg 11
Coils type AM
7.5 W ac9.5 W dc
• Compact• Windings of class H insulated wire moulded
in the coil body• Ambient temperature: Up to +50°C• All usual ac and dc voltages• IP 00 version with spade connector in
accordance with DIN 43650, form A• IP 20 version with protective cap• IP 65 version with mounted cable plug
Technical data Design In accordance with VDE 0580
Voltage tolerance ± 10%
Power consumption, cut-in ac: 22.5 VA
Power consumption, holding ac: 15 VA, 7.5 W / dc: 9.5 W
Insulation of coil windings Class H according to IEC 85
Connection Spade connector in accordance with DIN 43650 form A
Enclosure, IEC 529 IP 00: Spade connector; IP 20: Protective cap; IP 65: Cable plug
Ambient temperature Max. +50°C
Duty rating Continuous
Features
Ordering
Dimensions and weight
L
Without cable plug 48 mm
With protective cap 64 mm
With cable plug 72 mmWeight: 0.10 kg
Coil Supply Code no.type voltage IP 00
AM024C 24 V, 50/60 Hz 042N0842
7.5 W acAM110C 110 V, 50/60 Hz 042N0845
AM230C 220-230 V, 50/60 Hz 042N0840
AM240C 240 V, 50/60 Hz 042N0841
AM012D 12 V 042N08489.5 W dc AM024D 24 V 042N0843
Contact Danfoss for delivery of coils for other voltages
8 DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coil Supply Cable Code no.Type Voltage
6 W ac AR024C 24 V, 50/60 Hz 5.5 m 042N5525
6 W ac AR230C 230 V, 50/60 Hz 5.5 m 042N5535
7 W dc AR024D 24 V dc 5.5 m 042N5505
4.8 W dc AR024D 24 V dc 5.5 m 042N5515
Voltage tolerance ± 10%
Power consumption, holding ac: 6 W, dc: 4.8 W and 7 W
Insulation of coil windings Class H according to IEC 85
Connection 5.5 m 3-core cable
Enclosure, IEC 529 IP 65
Ambient temperature Max. +55° C
Media temperature Max. +90° C
Duty rating Continuous
Coils type AR; EEx m II T4
6 W ac4.8 W dc, 7 W dc
• Compact• The coils are suitable for use in
installations where flammable liquids andgases are produced, transported or tapped
• Approvals for use in Zone 1 according toDirective 94/9/EC (ATEX 100A) EN50014and EN50028
• Grade of enclosure IP 65 to IEC 529• Supplied with 5.5 m moulded-in
3-core cable
Technical data
Features
Ordering
Dimensions
Moulded-in 5.5 m, 3-core cableWeight approx. 0.3 kg
Special requirements:The supply must be secured against a too high power consumption in case of a short circuit
Conformity certification EX DEMKO 99ATEX 125689X
9DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coil type BA and BD
9 W/15 W ac15 W dc
IP 00
• Windings of class H insulated wire mouldedin the coil body
• Ambient temperature: Up to +40°C and+50οC
• All usual ac and dc voltages• IP 00 version with spade connector in
accordance with DIN 43650, form A• IP 20 version with protective cap• IP 65 version with mounted cable plug
Technical data Design In accordance with VDE 0580
Voltage tolerance 220/380 V ac coils: +10%, –15%. 230/400 V ac coils: +6%, –10%.Other ac coils with NC valve: +10%, –15%Other ac coils with NO valve and all dc coils: ±10%
Power consumption, cut-in BA ac: 39 VA BD ac: 54 VA
Power consumption, holding ac: 19 VA, 9 W / 29 VA, 15 W dc: 15W
Insulation of coil windings Class H according to IEC 85
Connection Spade connector in accordance with DIN 43650 form A
Enclosure, IEC 529 IP 00 with spade connec. IP 20 with protective cap; IP 65 with cable plug
Ambient temperature Max . +40°C for BA / Max. +50°C for BD
Duty rating Continuous
Ordering
Dimensions and weight
L
Without cable plug 54 mm
With protective cap 71 mm
With cable plug 79 mmWeight: 0.16 kg
Symbol Description Enclosure grade Code no.
Protective cap IP 20 018Z0282(pack of 100 pcs.)
Cable plug according to IP 65 042N0156
DIN 43650-A Pg 11
Features
Contact Danfoss for delivery of coils for other voltages
Coil Supply Code no.Type voltage IP 00
BA024A 24 V, 50 Hz 042N7508
BA048A 48 V, 50 Hz 042N7510
BA115A 115 V, 50 Hz 042N7512
BA230A 220-230 V, 50 Hz 042N7501
9 W ac BA240A 240 V, 50 Hz 042N7502
BA380A 380-400 V, 50 Hz 042N7504
BA024B 24 V, 60 Hz 042N7520
BA115B 115 V, 60 Hz 042N7522
BA220B 220 V, 60 Hz 042N7523
BD024A 24 V, 50 Hz 042N7597
15 W ac BD110A 110 V, 50 Hz 042N7599
BD230A 230 V, 50 Hz 042N7591
15 W dcBA012D 12 V 042N7550
BA024D 24 V 042N7551
10 DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coils type BB
10 W ac18 W dc
IP 00, IP 20IP 65
• Clip-on version• Windings of class H insulated wire
moulded in the coil body• Ambient temperature: Up to +80°C• All usual ac and dc voltages• IP 00 version with spade connector in
accordance with DIN 43650, form A.• IP 20 version with protective cap• IP 65 version with mounted cable plug
Technical data
Ordering
Dimensions and weight
L
Without cable plug 62 mm
With protective cap 77 mm
With cable plug 85 mmWeight: 0.24 kg
Design In accordance with VDE 0580
Voltage tolerance 220/380 V ac coils: +10%, –15%. 230/400 V ac coils: +6%, –10%.Other ac coils with NC valve: +10%, –15%Other ac coils with NO valve and all dc coils: ±10%
Power consumption, cut-in ac: 44 VA
Power consumption, holding ac: 21 VA, 10 W / dc: 18 W
Insulation of coil windings Class H according to IEC 85
Connection Spade connector in accordance with DIN 43650 form A
Enclosure, IEC 529 IP 00 with spade connec. IP 20 with protective cap; IP 65 with cable plug
Ambient temperature Max . +50/+80°C - see table below for details
Duty rating Continuous
Features
Contact Danfoss for delivery of coils for other voltages
Coil Ambient Supply Code no.
Type Temperature voltage IP 00
BB024AS max. +80°C 24 V, 50 Hz 018F7358
BB115AS max. +80°C 115 V, 50 Hz 018F7361
BB230AS max. +80°C 220-230 V, 50 Hz 018F7351
10 W ac BB240AS max. +80°C 240 V, 50 Hz 018F7352
BB380AS max. +80°C 380-400 V, 50 Hz 018F7353
BB024BS max. +80°C 24 V, 60 Hz 018F7365
BB110CS max. +50°C 110 V, 50/60 Hz 018F7360
BB230CS max. +50°C 220-230 V, 50/60 Hz 018F7363
18 W dc BB012DS max. +50°C 12 V 018F7396
BB024DS max. +50°C 24 V 018F7397
• Can be fitted without tools• Can only be removed with tool
Symbol Description Enclosure grade Code no.
Protective cap IP 20 018Z0282(pack of 100 pcs.)
Cable plug according to IP 65 042N0156
DIN 43650-A Pg 11
11DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coils type BE
10 W ac18 W dc
IP 67
• Clip-on version• Encapsulated coils with long operation life• Ambient temperature: Up to +80°C• Suitable for moist environments• All usual ac and dc voltages• IP 67 version with terminal box• IP 67 version 1 m 3-core flying lead• Can be fitted without tools• Can only be removed with tool
Technical data Design In accordance with VDE 0580
Voltage tolerance 220/380 V ac coils: +10%, –15%. 230/400 V ac coils: +6%, –10%.Other ac coils with NC valve: +10%, –15%Other ac coils with NO valve and all dc coils: ±10%
Power consumption, cut-in ac: 44 VA
Power consumption, holding ac: 21 VA, 10 W / dc: 18 W
Insulation of coil windings Class H according to IEC 85
Connection Terminal box; Pg 13.5 – or 1 m 3-core flying lead
Enclosure, IEC 529 IP 67
Ambient temperature Max . +50/+80°C, see table below for details
Duty rating Continuous
Ordering
Dimensions and weight
Weight: 0.30 kg
L
With terminal box 94 mm
With 1 m cable 65 mm
Features
Contact Danfoss for delivery of coils for other voltages
Coil Ambient Supply Code no.Type temperature voltage With terminal box With cable
BE024AS max. +80°C 24 V, 50 Hz 018F6707 018F6257
BE048AS max. +80°C 48 V, 50 Hz 018F6709 018F6259
BE115AS max. +80°C 115 V, 50 Hz 018F6711 018F6261
BE230AS max. +80°C 220-230 V, 50 Hz 018F6701 018F6251
BE240AS max. +80°C 240 V, 50 Hz 018F6702 018F6252
10 W ac BE380AS max. +80°C 380-400, 50 Hz 018F6703 018F6253
BE024BS max. +80°C 24 V, 60 Hz 018F6715 018F6265
BE115BS max. +80°C 115 V, 60 Hz 018F6710 018F6260
BE220BS max. +80°C 220 V, 60 Hz 018F6714 018F6264
BE110CS max. +50°C 110 V, 50/60 Hz 018F6730 018F6280
BE230CS max. +50°C 220-230 V, 50/60 Hz 018F6732 018F6282
18 W dcBE012DS max. +50°C 12 V 018F6756
BE024DS max. +50°C 24 V 018F6757
Application Code no.
O-ring Coil enclosures 018F0094Terminal box with 48-220 V dc
LED indication 24-250 V, 50/60 Hz 018Z0089
12 DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coils type BG
12 W ac20 W dc
IP 67
• Clip-on version• Encapsulated coils with long operation life• Ambient temperature: Up to +80°C• All usual ac and dc voltages• Suitable for moist environments• IP 67 version with terminal box• Can be fitted without tools• Can only be removed with tool
Technical data Design In accordance with VDE 0580
Voltage tolerance 220/380 V ac coils: +10%, –15%. 230/400 V ac coils: +6%, –10%.Other ac coils with NC valve: +10%, –15%Other ac coils with NO valve and all dc coils: ±10%
Power consumption, cut-in ac: 55 VA
Power consumption, holding ac: 26 VA, 12 W / dc: 20 W
Insulation of coil windings Class H according to IEC 85
Connection Terminal box; Pg 13.5
Enclosure, IEC 529 IP 67
Ambient temperature Max . +80°C
Duty rating Continuous
OrderingCoil Supply Code no.Type voltage IP 67
BG024AS 24 V, 50 Hz 018F6807
BG110AS 110 V, 50 Hz 018F6811
BG230AS 220-230 V, 50 Hz 018F6801
BG240AS 240 V, 50 Hz 018F6802
12 W ac BG380AS 380-400 V, 50 Hz 018F6803
BG024BS 24 V, 60 Hz 018F6815
BG110BS 110 V, 60 Hz 018F6813
BG220BS 220 V, 60 Hz 018F6814
20 W dcBG012DS 12 V 018F6856
BG024DS 24 V 018F6857
Dimensions and weight
L
With terminal box 112 mmWeight: 0.50 kg
Features
Contact Danfoss for delivery of coils for other voltages
Description Application Code no.
O-ring Coil enclosure 018F0094
13DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coil Supply Code no.type voltage IP 67
20 W ac BN230CS 220-230 V, 50/60 Hz 018F7301
O-rings Coil enclosure 018F0094
• Clip-on version• Windings of class H insulated wire moulded
in the coil body• For installations sensitive to noise, such as
heating systems• Ambient temperature: Up to +50°C• Built-in rectifier• Suitable for moist environments• Available with 1 m 3-core flying lead• Coil enclosure: IP 67
Technical data Design In accordance with VDE 0580
Voltage tolerance ±10%
Power consumption, cut-in ac: 24 VA
Power consumption, holding ac: 26 VA
Insulation of coil windings Class H according to IEC 85
Connection 1 m 3-core flying lead; Pg 13.5
Enclosure, IEC 529 IP 67
Ambient temperature Max . +50°C
Duty rating Continuous
Ordering
Dimensions and weight
Weight: 0.60 kgL
With 1 m cable 112 mm
Coils type BN
20 W acHum-free coil
IP 67
Features
14 DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Coils type BO; Eex m II T4
10 W ac10 W dc
IP 67
• For explosion-risk environments, such aswhere flammable liquids and gases areproduced, transported or tapped
• Approvals for use in Zone 1 according toDirective 94/9/EC (ATEX 100A) EN50014and EN50028
• Medium temperature: Up to +90°C• Ambient temperature: Up to +40°C• IP 67 version with 5 m 3-core flying lead• Seal kit as accessory for extremely wet and
aggressive environments (please contactDanfoss)
Technical data Voltage tolerance ±10%
Power consumption, holding ac: 10 W / dc: 10 W
Insulation of coil windings Class H according to IEC 85
Connection 5 m 3-core flying lead
Enclosure, IEC 529 IP 67
Ambient temperature Max . +40°C
Duty rating Continuous
Media temperature Max . +90°C
Ordering
Dimensions and weight
Weight: 0.60 kg
Features
Description Application Code no.
Seal kit Wet environment 018Z0090
Coil Supply Code no. type Voltage
BO024C 24V, 50/60Hz 018Z6595
10 W ac BO048C 48V, 50/60Hz 018Z6594
BO110C 110V, 50/60Hz 018Z6593
BO230C 230V, 50/60Hz 018Z6592
BO240C 240V, 50/60Hz 018Z6591
10 W dc BO24D 24V 018Z6596
Conformity certification EX DEMKO 99ATEX 128981X
15DKACV.PD.600.A4.02 Danfoss A/S 10-2002
Voltage tolerance ± 10%
Power consumption, holding dc: 16 W
Insulation of coil windings Class H according to IEC 85
Connection 3 m 3-core cable
Enclosure, IEC 529 IP 67
Ambient temperature Max. +55° C
Media temperature Max. +90° C
Duty rating Continuous
IP 67
Coils type BP; EEx m II T4
16 W dc
• The coils are suitable for use ininstallations where flammable liquids andgases are produced, transported or tapped
• Approved for use in Zone 1 according toDirective 94/9/EC (ATEX 100A) EN50014and EN50028
• Grade of enclosure IP 67• Supplied with 3 m moulded-in 3-core
cable
Technical data
Features
Ordering Conformity certification EX DEMKO 99ATEX 125688X
Coil Supply Connection Code no.Type Voltage
16 W dc BP024D 24 V dc 3 m 018Z6633
Dimensions
Special requirements:The supply must be secured against a too high power consumption in case of a short circuit
Moulded-in 3 m, 3-core cableWeight approx. 0.33 kg
Description Application Code no.
Seal kit Wet environment 018Z0090