1
Datasheet Applications: • Waste Incinerators • Thermal Oxidisers • Exhaust Gas Analysis • Standard Reference Method for VOC Monitoring • Laboratories and Research Centres • Process Control • Combustion Monitoring MCERTS Certification Range: TOC: 0-15mg/m 3 Specification: Ranges: 0-10/100/1000/10000 ppm or user programmable range up to 50 000 ppm Accuracy: < 1% of the displayed value between 15% and 100% of the F.S. Lower detectable limit: 0.05 ppm of the 10 ppm range Response time: < 1 sec. (T90) Zero drift: <1%/24h F.S. <2%/7 days F.S. Span drift: <1% / 7 days F.S. Linearity: <1% for concentration between 10 % and 90% of the scale Temperature of the heated block: up to 191°C Sample flow rate: 0.7 to 2 l/min Dimensions: 483 x 470 x 177mm (WxDxH) Weight: 22kg approximately Power supply: 230 VAC, 50Hz or 115 VAC, 60 Hz Power consumption: 500VA during start up Operating temperature: +5°C to +40°C Equipped with one burner placed in a heated block, the Graphite 52M allows continuous and accurate Total VOC monitoring. The FID is temperature controlled up to 191°C to eliminate condensation. Extremely compact and with a very short response time, this heated FID provides continuous monitoring of total VOC’s, in compliance with the Waste Incineration Directive and EN12619 standard as written in most WID permits. Features: • Detector placed in a heated oven, up to 191°C allowing measurement of high concentrations of heavy hydrocarbons • Fast response time • Real time graphic display with interactive menu driven software • Integrated zero air catalyst • Dual stream monitoring by independent detectors available • User selectable ranging • Very low limits of detection • Hydrogen/Helium fuel supply thus reducing oxygen interference • Fully compatible with the Environnement S.A. MIR-FT & MIR-9000 CEM systems • MCERTS Certified Environnement SA Graphite 52M Heated FID Volatile Organic Compounds Analyser The Graphite 52M is fully supported by MCERTS certified CDAS Elite Data Aquisition Software and a comprehensive service and support package Specification Certificate Number 996/96 026 t: +44(0)151 666 8300 f: +44(0)151 666 8329 e: [email protected] www.a1-cbiss.com
Transcript
Page 1: Data sheet g52 m print version

Datasheet

Applications: • Waste Incinerators• Thermal Oxidisers• Exhaust Gas Analysis• Standard Reference Method for VOC Monitoring• Laboratories and Research Centres• Process Control • Combustion Monitoring

MCERTS Certification Range:TOC: 0-15mg/m3

Specification:• Ranges: 0-10/100/1000/10000 ppm or user programmable range up to 50 000 ppm • Accuracy: < 1% of the displayed value between 15% and 100% of the F.S. • Lower detectable limit: 0.05 ppm of the 10 ppm range • Response time: < 1 sec. (T90) • Zero drift: <1%/24h F.S. <2%/7 days F.S. • Span drift: <1% / 7 days F.S. • Linearity: <1% for concentration between 10 % and 90% of the scale • Temperature of the heated block: up to 191°C• Sample flow rate: 0.7 to 2 l/min• Dimensions: 483 x 470 x 177mm (WxDxH)• Weight: 22kg approximately• Power supply: 230 VAC, 50Hz or 115 VAC, 60 Hz• Power consumption: 500VA during start up• Operating temperature: +5°C to +40°C

Equipped with one burner placed in a heated block, the Graphite 52M allows continuous and accurate Total VOC monitoring.

The FID is temperature controlled up to 191°C to eliminate condensation. Extremely compact and with a very short response time, this heated FID provides continuous monitoring of total VOC’s, in compliance with the Waste Incineration Directive and EN12619 standard as written in most WID permits.

Features:• Detector placed in a heated oven, up to 191°C allowing measurement of high concentrations of heavy hydrocarbons• Fast response time• Real time graphic display with interactive menu driven software• Integrated zero air catalyst• Dual stream monitoring by independent detectors available• User selectable ranging• Very low limits of detection• Hydrogen/Helium fuel supply thus reducing oxygen interference• Fully compatible with the Environnement S.A. MIR-FT & MIR-9000 CEM systems• MCERTS Certified

Environnement SA Graphite 52MHeated FID Volatile Organic

Compounds Analyser

The Graphite 52M is fully supported by MCERTS certified CDAS Elite Data Aquisition Software and a comprehensive service and support package

Specification

Certificate Number 996/96026

t: +44(0)151 666 8300 f: +44(0)151 666 8329 e: [email protected] www.a1-cbiss.com