+ All Categories
Home > Documents > Data Sheet H1 Axial Piston Pump 089/100 cm3 Single Pumpfiles.danfoss.com/documents/H1 089 100 Single...

Data Sheet H1 Axial Piston Pump 089/100 cm3 Single Pumpfiles.danfoss.com/documents/H1 089 100 Single...

Date post: 08-Apr-2018
Category:
Upload: dothu
View: 219 times
Download: 4 times
Share this document with a friend
2
11055369 • Rev DA • Oct 2013 Features y Designed for quality and reliability One design concept Single piece swash plate y Installation and packaging benefits Length optimized pump Minimum one clean side Higher corner power Higher package size ratio Standardized connector interface Expanded functionality through PLUS+1® Optimized for electrical control Electro-hydraulic control options include Electrical Displacement Control (EDC) Forward-Neutral-Reverse (FNR) and Non-Feedback Proportional Electric (NFPE) Automotive Control (AC) Fan Drive Control (FDC) Common control across entire family y Expanded functionality PLUS+1 Compliant control and sensor options Integral filtration available with integrated filter bypass sensors and switch y Greater total efficiency Minimized control losses Improved charge circuit Lower control pressure for less power consumption Data Sheet H1 Axial Piston Pump 089/100 cm 3 Single Pump Introduction For more than 40 years, Danfoss has been developing state-of-the-art components and systems for mobile machinery used in off-highway operations around the world. We have become a preferred supplier by offering the best of what really matters: The hardware inside your vehicle application. H1 - our new generation of servo-controlled hydrostatic pumps - is no exception. The H1 range is built around an advanced electrical control and available in a wide range of displacements. It is designed for quality and reliability and offers expanded functionality, greater total efficiency, and easy installation. All H1 control and sensor options are PLUS+1 Compliant. PLUS+1® allows you to rapidly develop and customize electronic machine control. It opens up the future by combining machine controls and diagnostics in an integrated operating network. MAKING MODERN LIVING POSSIBLE
Transcript
Page 1: Data Sheet H1 Axial Piston Pump 089/100 cm3 Single Pumpfiles.danfoss.com/documents/H1 089 100 Single Axial Piston Pumps... · H1 Axial Piston Pump ... hone 9 1 81 0 Danfoss Power

11055369 • Rev DA • Oct 2013

Features y Designed for quality and reliability – One design concept – Single piece swash plate

y Installation and packaging benefits – Length optimized pump – Minimum one clean side – Higher corner power – Higher package size ratio – Standardized connector interface – Expanded functionality through PLUS+1®

– Optimized for electrical control – Electro-hydraulic control options include

Electrical Displacement Control (EDC) – Forward-Neutral-Reverse (FNR) and

Non-Feedback Proportional Electric (NFPE) – Automotive Control (AC) – Fan Drive Control (FDC) – Common control across entire family

y Expanded functionality – PLUS+1 Compliant control and sensor

options – Integral filtration available with integrated

filter bypass sensors and switch

y Greater total efficiency – Minimized control losses – Improved charge circuit – Lower control pressure for less power

consumption

Data Sheet

H1 Axial Piston Pump089/100 cm3 Single Pump

IntroductionFor more than 40 years, Danfoss has been developing state-of-the-art components and systems for mobile machinery used in off-highway operations around the world. We have become a preferred supplier by offering the best of what really matters: The hardware inside your vehicle application.H1 - our new generation of servo-controlled hydrostatic pumps - is no exception.

The H1 range is built around an advanced electrical control and available in a wide range of displacements. It is designed for quality and reliability and offers expanded functionality, greater total efficiency, and easy installation.

All H1 control and sensor options are PLUS+1 Compliant. PLUS+1® allows you to rapidly develop and customize electronic machine control. It opens up the future by combining machine controls and diagnostics in an integrated operating network.

MAKING MODERN LIVING POSSIBLE

Page 2: Data Sheet H1 Axial Piston Pump 089/100 cm3 Single Pumpfiles.danfoss.com/documents/H1 089 100 Single Axial Piston Pumps... · H1 Axial Piston Pump ... hone 9 1 81 0 Danfoss Power

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss Power Solutions22F, Block C, Yishan RdShanghai 200233, ChinaPhone: +86 21 3418 5200

Danfoss Power Solutions GmbH & Co. OHGKrokamp 35D-24539 Neumünster, GermanyPhone: +49 4321 871 0

Danfoss Power Solutions ApSNordborgvej 81DK-6430 Nordborg, DenmarkPhone: +45 7488 2222

Danfoss Power Solutions US Company2800 East 13th StreetAmes, IA 50010, USAPhone: +1 515 239 6000

11055369 • Rev DA • Oct 2013 www.danfoss.com © Danfoss A/S, 2013-10

Data Sheet H1 Axial Piston Pump 089/100 cm3 Single Pump

Technical Specifications Schematic

Dimensions

System port ”B“∅25.4 - 450 barSplit ange bossper ISO 6162M12x1.7520 [0.79] min full thread depth

System port ”A“∅25.4 - 250 barSplit ange bossper ISO 6162M12x1.7520 [0.79] min full thread depth

Connector:Deutsch DT04-2P to be paint free

12.45 ±0.25[0.49 ±0.01]

99.0

±1.

0[3

.898

±0.

039]

139.176 ±1.0[5.479 ±0.039]

112.39 ±1.0[4.425 ±0.039]

187.

29 ±

1.0

[7.3

74 ±

0.03

9]

295.33 ±2.0[11.627 ±0.079]

Servo gauge port ”M4“Port ISO 11926-1 – 7/16 -20∅21 max. clearancedia for �tting

Charge inlet port ”S“Port ISO 11926-11 5/8 -12∅69 max. clearance dia for �tting

Case drain port ”L4“Port ISO 11926-1 – 1 1/16 -12∅48 max. clearance dia for �tting

∅12

7.0

-0

.05

[5.0

-0

.002

]

4x ∅14.34 + 0.3

– 0.1

[0.565 + 0.12

-0.004 ]

4x 5

7.25

±0.

25[2

.254

±0.

01]

4x 57.25 ±0.25[2.254 ±0.01]

ZX

Y

System B gauge port ”MB“Port ISO 11926-1 – 9/16 -18∅28 max. clearance dia for �tting

Case gauge port ”M14“Port ISO 11926-1 – 7/16 -20except spot face depth: 5 max.∅21 max. clearance dia for �tting

Charge �ltration port ”E“Port ISO 11926-1 – 7/8 -14 ∅42 max clearance dia for �ttingfrom �lter

Charge �ltration port ”F“Port ISO 11926-1 – 7/8 -14∅42 max clearance dia for �ttingto �lter

View Y

View X

Charge gauge port ”M3“Port ISO 11926-1 – 9/16 -18∅28 max. clearance dia for �ttingafter �ltering

Case drain port ”L2“Port ISO 11926-1 – 1 1/16 -12∅48 max. clearance dia for �tting

Servo gauge port ”M5“Port ISO 11926-1 – 7/16 -20∅21 max. clearance dia for �tting

Charge pressure portPort ISO 11926-1 – 5/16 -24

Case pressure portPort ISO 11926-1 – 1 1/16 -12∅48 max. clearance dia for �tting

Case pressure portPort ISO 11926-1 – 1 1/16 -12∅48 max. clearance dia for �tting

View Z

Connector:Deutsch DTM04-2P

285.6 ±1.0[11.244 ±0.0391]

SAE

C 22

1.15

±1.

0[8

.707

±0.

039]

All

othe

r 212

.65

±1.0

[8.3

72 ±

0.03

9]SA

E C

135.

765

±1.0

[5.3

45 ±

0.03

9]A

ll ot

her 1

27.2

65 ±

1.0

[5.0

10 ±

0.03

9]

294.4 ±1.0[11.591 ±0.0391]

71.4 ±1.0[2.812 ±0.0391]

Optional: Integrated charge pressure �ltration

Charge gauge port ”M6“Port ISO 11926-1 – 9/16 -18∅28 max. clearance dia for �ttingbefore �ltering

CCWRotation

CWRotation

P003 417S

F00B

C1 C2

F00A

M4

M5

M14

M3 L2 MA

A

CW

MB

B

M6 1 2R1

R2

L4

Physical properties

Features UnitSizes

089 100Displacement cm3 [in3] 89.2 [5.44] 101.7 [6.21]Weight (without PTO and fi lter) kg [lb] 62 [137]

Operating parameters

Input speed

Minimummin-1 (rpm)

500Rated 3300Maximum 3800

System pressure

Maximum working pressure*

bar [psi]450 [6525]

Maximum pressure 480 [6960]Minimum low loop 10 [150]

Case pressure

Ratedbar [psi]

3.0 [40]Maximum 5.0 [75]

* Applied pressures above maximum working pressure requires Danfoss application approval. T000 167E