Date post: | 05-Dec-2014 |
Category: |
Technology |
Upload: | mediehuset-ingenioren-live |
View: | 84 times |
Download: | 2 times |
THE DATA CENTRE CROSSROADS
Richard PowSales Manager – UK and Nordics
Efficiency
Cost
Carbon footprint
€
CO2
COLT DATA CENTRE PUE PERFORMANCE
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.02000 2001 2002 2003 2004 2005 2006 2007 2009 2010
PUEachieved
2011
Year DC built
Linear PUE
PUE
DC1 - DE
DC2 - FR
DC3 - BEDC4 - GB
DC5 - FR
DC6 - DKDC7 - IT
DC8 - PT
DC9 - SP
DC10 - SP
DC11 - UK DC12 - NL
2012
SHORT TERM FIXES
REGULATEAIRFLOW
REDUCEAIRFLOW
LEAKS
CHECKFLOORING
CONTROL AIR TEMPER-
ATURES
REGULATEHUMIDITY
TRANSFORMERVOLTAGE
AISLECONTAINMENT
REMOVE ISOLATION
TRANSFORMERS
MEASURE
MEASURE
TURN OFFREDUNDANTEQUIPMENT
ALIGN HOT / COLD
AISLES
SHORT TERM FIXES
REGULATEAIRFLOW
REGULATEHUMIDITY
TRANSFORMERVOLTAGE
TURN OFFREDUNDANTEQUIPMENT
ALIGN HOT / COLD
AISLES
AISLECONTAINMENT
REMOVE ISOLATION
TRANSFORMERS
MEASURE
MEASURE
REDUCEAIRFLOW
LEAKS
CHECKFLOORING
CONTROL AIR TEMPER-
ATURES
ALIGN CONTAINMENT
SHORT TERM FIXES
REGULATEAIRFLOW
REGULATEHUMIDITY
TRANSFORMERVOLTAGE
TURN OFFREDUNDANTEQUIPMENT
ALIGN HOT / COLD
AISLES
AISLECONTAINMENT
REMOVE ISOLATION
TRANSFORMERS
MEASURE
MEASURE
REDUCEAIRFLOW
LEAKS
CHECKFLOORING
CONTROL AIR TEMPER-
ATURES
ALIGN HOT / COLD AISLES
SHORT TERM FIXES
REGULATEAIRFLOW
REDUCEAIRFLOW
LEAKS
CHECKFLOORING
CONTROL AIR TEMPER-
ATURES
REGULATEHUMIDITY
TRANSFORMERVOLTAGE
AISLECONTAINMENT
REMOVE ISOLATION
TRANSFORMERS
MEASURE
MEASURE
REDUCEAIRFLOW
LEAKS
TURN OFFREDUNDANTEQUIPMENT
ALIGN HOT / COLD
AISLES
SHORT TERM FIXES
REGULATEAIRFLOW
REGULATEHUMIDITY
TRANSFORMERVOLTAGE
AISLECONTAINMENT
REMOVE ISOLATION
TRANSFORMERS
MEASURE
MEASURE
REDUCEAIRFLOW
LEAKS
CHECKFLOORING
CONTROL AIR TEMPER-
ATURES
REGULATE HUMIDITY
TURN OFFREDUNDANTEQUIPMENT
ALIGN HOT / COLD
AISLES
Reduction in PUE18 %
Cut in annual carbon emissions
15k=2800Tonnes carbon Trips around the worldReduction in
annual energy bill
€4m
REAL BUSINESS RISK
RISK
0yrs
15yrs
REAL BUSINESS RISK
0yrs
15yrs
RISK
Take action.
1-3yrs
Application Lifecycle
3-5yrsCompute
EquipmentLifecycle
10-20yrsData Centre
Lifecycle
REINVEST
RELOCATE
DO NOTHING
MEDIUM TERM FIXESSHORT TERM FIXES
FAILURE RATE?COST OF
MAINTENANCE?EQUIPMENT LIFECYCLE?
COOLING SYSTEM?
REPLACEMENT?DOWNTIME?
360° APPROACH?
€
Chiller equipment UPS & DC rectifiersUpdate / replace
room cooling units
COST:
TIMELINE:
MANPOWER:
RISK:
CONSIDERATIONS:
LIFECYCLE:years
10-15years
10-15years
10-15
Dimensions Software Capacity
Software Pumps/pressure
Change over Testing Synchronisation
6 months 12 months 6 months
REINVEST
RELOCATE
DO NOTHING
TIME TO RELOCATE?
Equipment end of life?
Manufacturer support?
Maintenance costs?
Spare parts?
Running costs?€
TIME TO RELOCATE?
How critical is compute?
Data risk?
Business changes?
Future capacity?
BUSINESS SCENARIOS
Higher density activity
Decrease business activity
Exponential growth
M&A
Consolidation
Build your data centre needs around your business Don’t fit your
business to your data centre
SO WHAT ARE YOUR OPTIONS?
Build
Virtualisation Consolidation
Cloud
InsourcingColocation
Outsourcing
Navigate your way through the options available
DO NOTHINGREINVEST
RELOCATE
1Clear destination
2 Plan your route
3 Know the rules