+ All Categories
Home > Documents > Datalogic DS 4600 A

Datalogic DS 4600 A

Date post: 02-Mar-2018
Category:
Upload: jlnavarro
View: 223 times
Download: 0 times
Share this document with a friend

of 59

Transcript
  • 7/26/2019 Datalogic DS 4600 A

    1/59

    DS4600A

    Reference Manual

  • 7/26/2019 Datalogic DS 4600 A

    2/59

  • 7/26/2019 Datalogic DS 4600 A

    3/59

    DS4600A

    INSTALLATION MANUAL

  • 7/26/2019 Datalogic DS 4600 A

    4/59

    DATALOGIC S.p.A.Via Candini 240012 Lippo di Calderara di Reno

    Bologna - Italy

    DS4600A Reference Manual

    Ed.: 06/2003

  • 7/26/2019 Datalogic DS 4600 A

    5/59

    CONTENTS

    GUIDE TO INSTALLATION ...........................................

    GENERAL VIEW ............................................................

    SAFETY PRECAUTIONS...............................................Laser Safety...................................................................Power Supply.................................................................

    1 GENERAL FEATURES ..................................................1.1 Introduction ....................................................................1.2 Description.....................................................................

    1.3 Available Models............................................................1.4 Accessories....................................................................

    2 INSTALLATION..............................................................2.1 Package Contents...........................................................2.2 Mechanical Installation...................................................2.3 Electrical Connections ...................................................

    2.3.1 Power Supply.................................................................2.3.2 Main Serial Interface ......................................................

    RS232 Interface ..............................................................RS485 Full-Duplex Interface...........................................RS485 Half-Duplex Interface ..........................................20 mA Current Loop (INT-24 Accessory Only)................

    2.3.3 Auxiliary RS232 Interface................................................

    2.3.4 Inputs .............................................................................2.3.5 Outputs ..........................................................................2.4 Positioning .....................................................................2.5 Typical Layouts ..............................................................2.5.1 Point-to-Point .................................................................2 5 2 Pass Through

  • 7/26/2019 Datalogic DS 4600 A

    6/59

    3 READING FEATURES

    3.3 Performance ..................................................................3.4 Reading Diagrams .........................................................

    4 MAINTENANCE..............................................................4.1 Cleaning..........................................................................

    5 TECHNICAL FEATURES ...............................................

  • 7/26/2019 Datalogic DS 4600 A

    7/59

    GUIDE TO INSTALLATION

    The following can be used as a checklist to verify all of the complete installation of the DS4600A scanner.

    1) Read all information in the section "Safety Precautions" at manual.

    2) Correctly position and mount the scanner for barcode readinformation in paragraphs 2.2, 2.4 and 3.4.

    3) Provide correct system cabling according to the signals application (see the applicable sub-paragraphs under 2.3).

    4) Install the WinHost Configuration program from the CD.Upon successful completion of the installation, the readme fdetails about how to get started configuring your scanner.See also the Guide to Rapid Configuration link in the Help OnSpecific parameter details are also available in the Help On L

    NOTE

    Fine tuning of the scanner position for barcodeaccomplished using the Test Mode as described in

    The installation is now complete.

  • 7/26/2019 Datalogic DS 4600 A

    8/59

    GENERAL VIEW

    DS4600A

    DS4600A - 2XXX Models

    DS4600A - 3

    Figure A

    1

    4

    5

    6

    7

    89

    10

    11

  • 7/26/2019 Datalogic DS 4600 A

    9/59

    SAFETY PRECAUTIONS

    LASER SAFETY

    The following information is provided to comply with the international authorities and refers to the correct use of the DS46

    Standard Regulations

    This scanner utilizes a low-power laser diode. Although staringbeam momentarily causes no known biological damage, avoid stone would with any very strong light source, such as the sun.

    beam hits the eye of an observer, even through reflective surfaetc.

    This product conforms to the applicable requirements of both EN21 CFR 1040 at the date of manufacture. The scanner is classifieproduct according to EN 60825-1 regulations and as a Claaccording to CDRH regulations.

    There is a safety device which allows the laser to be switched orotating above the threshold for its correct scanning speed.

    The laser beam can be switched off through a software comWinHost Help On Line).

    WARNING

    Use of controls or adjustments or performance ofthan those specified herein may result in exposvisible laser light.

  • 7/26/2019 Datalogic DS 4600 A

    10/59

    The laser light is visible to the human eye and is emitted from the

    of the scanner (Figure A, 2).Warning labels indicating exposure to laser light and the deviapplied onto the body of the scanner (Figure A, 4 and 10).

    DATALOGIC S.p.A. Via Candini, 240012 LIPPO DI CALDERARA (BO) ITALY

    Model No. Serial No.

    Volt Amp.

    Manufactured

    This product conforms to the applicable req21CFR1040 at the date of manufacture.

    LASER LIGHT

    DO NOT STARE INTO BEAM

    CLASS 2 LASER PRODUCTMAXIMUM OUTPUT RADIATION 1 m

    EMITTED WAVE LENGTH 630~680 n

    TO IEC 825-1 (1993)

    Warning and device class labels

    For installation, use and maintenance it is not necessary to open

    The laser diode used in this device is classified as a class 3B lasto EN 60825-1 regulations and as a Class IIIb laser product regulations. As it is not possible to apply a classification label on in this device, the following label is reproduced here:

    LASER LIGHT

    AVOID EXPOSURE TO BEAM

    CLASS 3B LASER PRODUCT

  • 7/26/2019 Datalogic DS 4600 A

    11/59

    POWER SUPPLY

    - This product is intended to be installed by Qualified Perso

    - Model DS4600A-XXX0:This device is intended to be supplied by a UL Listed DirUnit marked "Class 2", rated 10-30 V, minimum 0.60 A.

    This device may also be supplied by a UL Listed Power Un

    LPS power source which supplies power directly to the scconnector.

    - Model DS4600A-2XX5:This device is intended to be supplied by a UL Listed DirUnit marked "Class 2", rated 24 V, minimum 0.50 A.

    This device may also be supplied by a UL Listed Power Un

    LPS power source which supplies power directly to the scconnector.

    See par. 2.3.1 for correct power supply connections.

  • 7/26/2019 Datalogic DS 4600 A

    12/59

  • 7/26/2019 Datalogic DS 4600 A

    13/59

    GENERAL FEATURES

    1 GENERAL FEATURES

    1.1 INTRODUCTION

    The DS4600A is a compact laser scanner complete with decproduced to be a flexible and affordable solution for all medihandling applications.

    Standard Application Program

    A Standard Application Program is factory-loaded onto the DS4controls barcode reading, serial port interfacing, data formattoperating and control parameters.

    It is completely user configurable from a host computer using thutility program provided on CD with the scanner or usinprogramming procedure, by ESC sequences via the serial interfa

    There are four different programmable operating modes to sreading system requirements. Included in these is a test mode features and exact positioning of the scanner without using exter

    Programmability

    If your requirements are not met by the Standard ApplicatioApplication Programs can be developed by your local Datalogic d

  • 7/26/2019 Datalogic DS 4600 A

    14/59

    1

    1.2 DESCRIPTION

    Some of the main features of this scanner are given below:

    long-range reading

    scanning speed 800 scans/sec

    completely configurable from host computer

    2 serial communication interfaces

    reads most popular codes

    supply voltage from 10 to 30 Vdc

    test mode to verify the reading features and exact positiowithout the need for external tools

    configurable in different operating modes to suit the most varsystem requirements

    code verifier

    possibility to detect the position of the label in the scan line

    The DS4600A scanner uses a solid state laser diode as a ligemitted has a wavelength between 630 and 680 nm. Refer toPrecautions" at the beginning of this manual for information on la

    The reader is contained in a rugged aluminum housing; the meare 101 x 83.5 x 42 mm and it weighs about 615 g.

    The protection class of the enclosure is IP65, therefore the rsuitable for industrial environments where high protection agconditions is required.

  • 7/26/2019 Datalogic DS 4600 A

    15/59

    GENERAL FEATURES

    Electrical connection is provided through a cable on the side of t

    is terminated with a 25-pin connector (see Figure A, 1).The laser beam output window is on the right hand side of the sc

    A security system allows the laser to activate only once the mocorrect rotational speed; consequently the laser beam is gendelay from the power on of the scanner.

    The four LEDs on the left hand side of the scanner indicate the fo

    READY (red), indicates the reader is connected to the pstartup was successful. If the startup is not sblinks. (Figure A, 9).

    GOOD READ (red), is used to signal successful barcode dec

    in Test mode to signal the decoding percentagthe WinHost Help On Line). (Figure A, 8).

    EXT TRIG (yellow), indicates external trigger activity par. 2.3.4. (Figure A, 7).

    TX DATA (green), indicates data transmission on the ma

    (Figure A, 6).

    The screw holes on the body of the reader are for mechanical the screw holes shown in Figure A, 3 are to attach accessories 90 mirror.

  • 7/26/2019 Datalogic DS 4600 A

    16/59

    1

    1.3 AVAILABLE MODELS

    The DS4600A scanner is available in versions that differ in regcharacteristics:

    Decoding Mode Special Features

    Reading Range Linear or Raster read

    The following models are therefore available:

    DS4600A - XXXX

    Decoding Mode

    2 = Standard w/ Display

    3 = Advanced Code Reconstruction

    Reading Range

    0 = Medium Range

    1 = Long Range

    2 = Short Range

    Special F

    0 = Standa5 = Integra

    Linear/Ra

    0 = Linea

    1 = Raste

    2 = Raste

    1.4 ACCESSORIES

    The following accessories are available on request for the DS460 Connection Box C-Box 1

    Connection Box Profibus C-Box 3

    90 deflection mirror GFC 41

  • 7/26/2019 Datalogic DS 4600 A

    17/59

    INSTALLATION

    2 INSTALLATION

    2.1 PACKAGE CONTENTS

    Verify that the DS4600A reader and all the parts supplied withpresent and intact when opening the packaging; the list of parts i

    DS4600A reader with cable

    Quick Reference Guide

    Barcode Test Chart

    WinHost CD

    Mounting kit: - Mounting screws and washers (4 ea.)- Mounting bracket (1)

  • 7/26/2019 Datalogic DS 4600 A

    18/59

    2

    2.2 MECHANICAL INSTALLATION

    DS4600A can be installed to operate in different positions. T(M4 x 5) on the body of the reader are for mechanical fixture (Fig

    The diagram below gives the overall dimensions of the scanner its installation.

    Refer to paragraph 2.4 for correct positioning.

    100.39

    41.8

    1.64

    M4 N 4

    371.47

    50.2

    11.

    8

    0.

    46

    8

    1

    3.19

    8.

    25

    0.3

    2

    87.

    9

    3.4

    6

    M4 N2

    58

    2.

    28

    32.

    5

    1.

    28

    3.750.15

    421.65

    20

    0.

    79

    83.53.29

    10

    1

    3.9

    8

    18

    0.

    70

    0.9023

    DS

    37

    20.2

    1.4

    6

    22*

    0.86

    0.8

    14.80.58

    39.

    4

    1.5

    5

    * The quote refers to the scanMounting hole depth M4 X 5

    Figure 2 - Overall Dimensions for 2XXX Models

    100.39

    41.81.64

    81

    3.1

    9

    8.

    25

    0.

    32

    87.9

    3.

    46

    M4 N2

    58

    2.

    28

    37

    20.2

    1.4

    6

    18*

    0.71

    0.814.80.58

    39.

    4

    1.5

    5

    101

    3.98

    20

    0.

    79

    3.2983.5

  • 7/26/2019 Datalogic DS 4600 A

    19/59

    INSTALLATION

    5.5

    0.

    22

    115

    4.

    53

    57.3

    2.26

    5.5

    0.2210

    5

    39

    1.

    54

    5.

    5

    0.

    22

    3

    0.

    12

    5.5

    0.22

    35

    0.20

    Figure 4 - Mounting Bracket Dimensions

  • 7/26/2019 Datalogic DS 4600 A

    20/59

    2

    2.3 ELECTRICAL CONNECTIONS

    DS4600A is equipped with a cable terminated by a 25-pin connection to the power supply and input/output signals. The detpins are indicated in the following table:

    CAUTION

    Do not connect GND and SGND to different references. GND and SGND are internally co

    filtering circuitry which can be permanently damagvoltage drops over 0.8 Vdc.

    Figure 3 - 25-pin D-sub Connector

    25-pin D-sub connector pinout

    Pin Name Function

    13 VS Power supply input voltage +

    25 GND Power supply input voltage -1 CHASSIS Chassis Ground9 VS External Trigger supply voltage +

    18 EXT TRIG+ External Trigger +19 EXT TRIG- External Trigger -6 IN1 + Input 1 +

    10 IN1 - Input 1 -14 IN2 + Input 2 +

    15 IN2 - Input 2 -8 OUT1 + Output 1 +22 OUT1 - Output 1 -11 OUT2 + Output 2 +12 OUT2 - Output 2 -20 RXAUX Auxiliary RS232 input

  • 7/26/2019 Datalogic DS 4600 A

    21/59

    INSTALLATION

    2.3.1 Power Supply

    Power can be supplied to the scanner through the pins proconnector used for communication with the host (Figure 4):

    DS4600A

    13

    25

    VS

    GND

    1CHASSIS

    Earth Ground

    USER INT

    CHAS

    GND

    V+ (1

    Figure 4 - Power Supply Connections

    or through the jack connector on the side of the 25-pin connectorUL Listed Direct Plug-in Power Unit (Figure 5). If the jack inppower to the DS4600A, pin 13 is automatically disconnected; th

    the external trigger remains on pin 9. The plug connector is nDS4600A.

    V+ (10 - 30 Vdc)

    Jack Plug

    GND

  • 7/26/2019 Datalogic DS 4600 A

    22/59

    2

    2.3.2 Main Serial Interface

    The signals relative to the following serial interface types ainput/output connector:

    RS232

    RS485 FULL DUPLEX

    RS485 HALF DUPLEX

    An active 20-mA Current Loop interface is available if the optionis installed. This accessory interface replaces the RS232/RS485

    The main serial interface type and its relative parameters (betc.) are selected via software either using the WinHost utiliMode programming. For more details refer to the section "Min the WinHost Help On Line.

    Details regarding the connections and use of the main interface sthe next paragraphs.

    RS232 Interface

    The serial interface is used in this case for point-to-point concommunication with the host computer and allows both transmand the configuration of the scanner. This is the default interface

    The following pins of the 25-pin connector are used for RS232 in

    Pin Name Function

    2 TX232 transmitted data3 RX232 received data4 RTS232 t t d

  • 7/26/2019 Datalogic DS 4600 A

    23/59

    INSTALLATION

    RTS/CTS HARDWARE HANDSHAKING ENABLED

    DS4600A USER INTE

    7 SGND MainSGND

    RTS2324DCD

    CTS2325DTR

    RX2323TXD

    TX2322RXD

    EarthGround

    Figure 6 - RS232 Main Interface Connections

    The RTS232 and CTS232 signals control data transmission aconnected devices.

  • 7/26/2019 Datalogic DS 4600 A

    24/59

    2

    RS485 Full-Duplex Interface

    The RS485 full-duplex (5 wires + shield) interface is ucommunication protocols in point-to-point connections over lon1200 m / 3940 ft) than those acceptable for RS232 communicatnoisy environments.

    The following pins of the 25-pin connector are used forcommunications:

    Pin Name Function

    2 TX485+ RS485 transmitted data4 TX485- RS485 transmitted data3 RX485+ RS485 received data +5 RX485- RS485 received data -

    7 SGND Main signal ground main inte

    DS4600A USER INTE

    7 SGND Main

    TX485+2

    TX485-4

    RX485+3

    RX485-5

    RX485

    TX485

    RS485REF

    EarthGroun

    Figure 8 - RS485 Full-Duplex Connections

  • 7/26/2019 Datalogic DS 4600 A

    25/59

    INSTALLATION

    RS485 Half-Duplex Interface

    The RS485 half-duplex (3 wires + shield) interface is used for pprotocols.

    It can be used for Multidrop connections in a master/slave layouMultiplexer, (see par. 2.5.4 and 2.5.5).

    The following pins of the 25-pin connector are used for communications:

    Pin Name Function

    2 RTX485+ RS485 transmitted/received4 RTX485- RS485 transmitted/received7 SGND Main signal ground main interface

    DS4600A MULTIPLE

    RTX485+2

    RTX485-4

    RTX485+

    RTX485-

    7 SGND Main RS485R

    Figure 9 - RS485 Half-Duplex Connections

  • 7/26/2019 Datalogic DS 4600 A

    26/59

    2

    The figure below shows a multidrop configuration with DS4600A to a Multiplexer.

    1

    1CHASSIS

    # 1

    RTX485+

    RTX485-

    SGND Main# 0

    three wires+ shield

    7

    4

    2

    7

    4

    2

    120 Ohm

    MULTIPLEXER

    RTX485+

    RTX485-

    RS485REF

    SHIELD

    1

    120 Ohm

    DS4600A

    (up to 31)

    # x

    max. 2 m.

    7

    4

    2

    DS4600A

    DS4600A

  • 7/26/2019 Datalogic DS 4600 A

    27/59

    INSTALLATION

    20 mA Current Loop (INT-24 Accessory Only)

    When the INT-24 accessory board is installed, the DS4600A20 mA active current loop interface.

    The following pins of the 25-pin connector are used for the connec

    Pin Name Function

    4 CLOUT- current loop output5 CLIN- current loop input7 SGND Main signal ground main inte

    DS4600A USER INTERF

    MAX. 300 METERS

    4 C.L. OUT -

    7 SGND Main GND

    I = 20 mA

    5 C.L. IN -

    I = 20 mA

    +

    +

    Figure 11 - 20 mA Active C.L. Connections

    For 20 mA passive current loop interface connections, contact representative.

  • 7/26/2019 Datalogic DS 4600 A

    28/59

    2

    2.3.3 Auxiliary RS232 Interface

    The auxiliary serial interface is used exclusively for Rconnections.

    The parameters relative to the auxiliary interface (baud rate, dataparticular communication modes such as Local Echo can beWinHost utility program or Host Mode programming. For mparagraph 2.5 and to the section "Auxiliary Interface Menu" in thLine.

    The following pins of the 25-pin connector are used to connectinterface:

    Pin Name Function

    20 RXAUX auxiliary RS232 received d21 TXAUX auxiliary RS232 transmitte23 SGND Aux signal ground auxiliary inte

    SGND

    DS4600A USER INTE

    TXD

    RXAUX20

    RXDTXAUX21

    SGND Aux23

    Figure 12 - RS232 Auxiliary Interface Connection

    When the auxiliary interface is permanently connected as part oit is recommended to connect the cable shield to earth ground.

    INSTALLATION

  • 7/26/2019 Datalogic DS 4600 A

    29/59

    INSTALLATION

    2.3.4 Inputs

    There is an input available on the DS4600A scanner relative to th

    There are also 2 general purpose inputs:

    IN1 can be used to store the code verifier (see "Store verifier Help On Line).

    IN2 can be used as the Reading Field Control signal which d

    Code Reading Condition or the Code Resolution parameter for Refer to the WinHost Help On Line.

    The pinouts are indicated below:

    Pin Name Function

    18 EXT TRIG+ external trigger +19 EXT TRIG- external trigger -6 IN1+ input 1 +

    10 IN1- input 1 -14 IN2+ input 2 +15 IN2- input 2 -

    The EXT TRIG inputs are used in the On-Line Operating mode ato scan for a code. The active state of this input is selected in sWinHost Help On Line. The yellow led, (Figure A, 7), is on whensignals the active reading phase.

    These inputs are optocoupled and can be driven by both ancommand. The connections are indicated in the following diagram

    18/6/14 +

    USER INDS4600A

    + 5V

    V

    30 Vdc max.Vext

  • 7/26/2019 Datalogic DS 4600 A

    30/59

    2

    18/6/14 +

    19/10/15 -

    USER INTEDS4600A

    + 5V

    VS9

    25 GNDGround

    V

    Figure 14 - Input NPN Command Using DS4600A P

    18/6/14 +

    19/10/15 -

    + 5V

    DS4600A USER IN

    V

    Grou

    30 Vdc max.Vext

    Figure 15 - Input PNP Command Using External Po

    18/6/14 +

    USER INTEDS4600A

    VS9 V

    + 5V

    INSTALLATION

  • 7/26/2019 Datalogic DS 4600 A

    31/59

    INSTALLATION

    The electrical features of the inputs are:

    Maximum voltage = 30 VdcMaximum current = 25 mA.

    An anti-disturbance hardware filter is implemented on the Externmilliseconds delay).

    An additional 15 ms (typical) delay can be implemented through parameter (refer to WinHost Help On Line).

    2.3.5 Outputs

    The following pins are present on the 25-pin connector of the sca

    Pin Name Function

    8 OUT1+ output 1 +22 OUT1- output 1 -11 OUT2+ output 2 +12 OUT2- output 2 -

    The meaning of the two outputs OUT1 and OUT2 can be defiRead, Right or Wrong). Refer to WinHost Help On Line.

    By default, OUT1 is associated with the No Read event, whichcode signaled by the External Trigger is not decoded. OUT2 isRight event, which activates when the code is decoded correctly.

    DS4600A USER INT

    Vext

  • 7/26/2019 Datalogic DS 4600 A

    32/59

    2

    2.4 POSITIONING

    The DS4600A scanner is able to decode moving barcode laangles, however significant angular distortion may degrade readi

    When mounting the DS4600A take into consideration these threangles:Pitch 0, Skew 15 to 30 and Tilt 0.

    Follow the suggestions below for the best orientation:

    The Pitchangle is represented by the value P in Figure 18. Porder to minimizethe Pitchangle.

    Figure 18 - Pitch Angle

    The Skewangle is represented by the value S in Figure 19. Passure at least 15 for the Skewangle. This avoids the direct rlight emitted by the DS4600A.

    For raster models, this angle refers to the most inclined or externall other raster lines assure more than 10 Skew.

    P

    INSTALLATION

  • 7/26/2019 Datalogic DS 4600 A

    33/59

    INSTALLATION

    The Tiltangle is represented by the value Tin Figure 20. Positioto minimizethe Tiltangle.

    Figure 20 - Tilt Angle

    2.5 TYPICAL LAYOUTS

    The following typical layouts refer to system hardware configurathe figures refer to optional hardware configurations within the pa

    These layouts also require the correct setup of the sofparameters. Complete software configuration procedures can beTo Rapid Configurationin the WinHost Help On Line.

    T

    2

  • 7/26/2019 Datalogic DS 4600 A

    34/59

    2

    2.5.1 Point-to-Point

    In this layout the data is transmitted to the Host on the main sMode programming can be accomplished either through the mauxiliary interface.

    The possible main interface types for the scanner are RS232 or(20 mA C.L. can also be used if the INT-24 accessory is installed

    In Local Echo communication mode, data is transmitted on interface independently from the main interface selection.

    When On-Line Operating mode is used, the scanner is activaTrigger (photoelectric sensor) when the object enters its reading

    Main Serial InterfaceAuxiliary Serial Interface (Local Echo) (RExternal Trigger (for On-Line Mode)

    Figure 21 - Point-to-Point Layout

    INSTALLATION

  • 7/26/2019 Datalogic DS 4600 A

    35/59

    2.5.2 Pass Through

    Pass through mode allows two or more devices to be connectedserial interface.

    Each DS4600A transmits the messages received by the auxiliamain interface. All messages will be passed through this chain to

    When On-Line Operating mode is used, the scanner is activa

    Trigger (photoelectric sensor) when the object enters its reading

    The main and auxiliary ports are connected as shown in the figur

    Main Serial Interface (RS232)Auxiliary Serial Interface (RS232)External Trigger (for On-Line Mode)

    Figure 22 - Pass Through Layout

    2

  • 7/26/2019 Datalogic DS 4600 A

    36/59

    2

    2.5.3 RS232 Master/Slave

    The RS232 master/slave connection is used to collect data frombuild a multi-sided reading system; there can be one master connected together.

    The slave scanners are connected to the main and auxiliary seslave DS4600A transmits the messages received by the auxiliamain interface. All messages will be passed through this chain to

    The master scanner is connected to the Host on the main spossible main interface types for the Master scanner are RSDuplex. (20 mA C.L. can also be used if the INT-24 accessory is

    Either On-Line or Serial On-Line Operating modes can be used in

    When On-Line Operating mode is used, the external trigger sigsystem however it is not necessary to bring the external triggescanners.

    The main and auxiliary ports are connected as shown in the figur

    INSTALLATION

  • 7/26/2019 Datalogic DS 4600 A

    37/59

    2.5.4 RS485 Master/Slave

    The RS485 master/slave connection is used to collect data frombuild a multi-sided reading system; there can be one master connected together.

    The slave scanners are connected together using RS485 halfserial interface. Every slave scanner must have a multidrop addre

    The master scanner is also connected to the Host on the RS

    interface.The External Trigger signal is unique to the system; there is a sand a single message from the master scanner to the Host comp

    It is necessary to bring the External Trigger signal to all the scann

    The main and auxiliary ports are connected as shown in the figur

    A ili S i l I t f (RS232)

    2

  • 7/26/2019 Datalogic DS 4600 A

    38/59

    2

    2.5.5 Multiplexer

    Each scanner is connected to an MX4000 with the RS485 half main interface.

    Main Serial Interface (RS485 Half-DupleAuxiliary Serial Interface (Local Echo) (R

    External Trigger (for On-Line Mode)Figure 25 - Multiplexer Layout

    The auxiliary serial interface of the slave scanners can be communication mode to control any single scanner (visualize configure it using the WinHost utility or Host Mode Programming

    When On-Line Operating mode is used, the scanner is activaTrigger (photoelectric sensor) when the object enters its reading

    INSTALLATION

  • 7/26/2019 Datalogic DS 4600 A

    39/59

    2.6 USER INTERFACE

    RS232 PC-side connections

    1 5

    96

    9-pin male connector

    14

    1

    25-pin male c

    Pin Name Pin

    2 RX 33 TX 25 GND 77 RTS 4

    8 CTS 5

    How To Build A Simple Interface Test Cable:

    The following wiring diagrams show a simple test cable includ(push-button) trigger and PC RS232 COM port connections.

    25-pin D-sub male

    7

    20

    SGND

    RXAUX

    TXAUX21

    DS4600A 25

    13

    GND

    VS

    9-pin

    2

    3

    5

    18

    9

    EXT TRIG+

    VS

    3

  • 7/26/2019 Datalogic DS 4600 A

    40/59

    3 READING FEATURES

    3.1 ADVANCED CODE RECONSTRUCTION

    The traditional way of barcode reading could be called "Linear Rthe laser beam crosses the barcode symbol from its beginning toFigure 26.

    Laser B

    Figure 26 - Linear reading

    In Advanced Code Reconstruction mode, it is no longer necbeam to cross the label from the start to the end. With just a sethe label (obtained using the motion of the label itself), the D"reconstruct" the barcode. A typical set of partial scans is shown

    Code Direction

    Figure 27 - Partial scans

    READING FEATURES

  • 7/26/2019 Datalogic DS 4600 A

    41/59

    3.1.1 Tilt Angle for Advanced Code Reconstruc

    The most important parameter in Advanced Code Reconstructiomaximum tilt angle (maximum) under which the code reconstrpossible.

    We define the Tilt angle as the angle () between the laser beato the barcode label, as shown in Figure 28.

    Laser Beam

    = tilt ang

    0 to m

    Figure 28 - Tilt angle

    The formulas to calculate maximum depend on various paramheight, number of scans per second, code motion speed, etc. Tfor your application, please contact your Datalogic representative

    You must remember that the decoder will be able to read the lbetween + max and - max as shown in Figure 29 (the shadeREAD zones).

    - +

    0

    3

  • 7/26/2019 Datalogic DS 4600 A

    42/59

    3.2 DECODING CAPACITY IN LINEAR MODE

    When in Linear Reading mode, the number of reads performed btherefore the decoding capacity, is influenced by the following pa

    number of scans per second

    code motion speed

    label dimensions

    scan direction with respect to code motion

    At least 5 scans during the code passage should be allowed to read.

    3.2.1 Step Ladder Mode

    Direction of cmovement at

    Laser

    DS4600A LH

    READING FEATURES

  • 7/26/2019 Datalogic DS 4600 A

    43/59

    If scanning is perpendicular to the direction of the code movemnumber of effective scans performed by the reader is given by th

    SN = [(LH/LS) *SS] - 2

    These symbols signify:

    SN = number of effective scansLH = label height (in mm)LS = label movement speed (in mm/s)

    SS = number of scans per second

    For example, the DS4600A (800 scans/sec.), for a 25 mm high cmm/s performs:

    [(25/1250) *800] - 2 = 14 effective scans.

    3.2.2 Picket Fence Mode

    Direction of comovement at

    LaDS4600A

    FW

    LW

    3

  • 7/26/2019 Datalogic DS 4600 A

    44/59

    If scanning is parallel to the code movement (Figure 31) the scans is given by:

    SN = [((FW-LW)/LS) *SS] - 2

    These symbols signify:

    SN = number of effective scansFW = reading field width (in mm)LW = label width (in mm)

    LS = label movement speed (in mm/s)SS = scans per second

    For example, for a 100 mm wide code moving in a point where200 mm wide at a 2000 mm/s speed, the DS4600A (800 scans p

    [((200-100)/2000) *800] - 2 = 38 scans

    3.3 PERFORMANCE

    The DS4600A scanner is available in different versions accoperformance.

    Version Max Code Resolution Speed

    mm (mils) scans/s

    21XX / 31XX 0.50 (20) 800

    20XX / 30XX 0.25 (10) 800

    220X / 32XX 0.20 (8) 800

    Version Reading Distance

    READING FEATURES

  • 7/26/2019 Datalogic DS 4600 A

    45/59

    The reading characteristics for the raster versions are given in distance between the top and bottom scan lines is given

    distances measured from the laser beam output window.

    Reading Distance

    Version 150 mm

    (5.9 in)

    500 mm

    (20 in)

    2X1X (R1) 7.5 mm

    (0.30 in)

    24 mm

    (0.94 in)

    2X2X (R2) 16 mm

    (0.62 in)

    45 mm

    (1.77 in)

    Refer to the diagrams given in paragraph 3.4 for further defeatures. These diagrams are taken on various resolution sampambient temperature, depending on the conditions in the notes u

    If standard devices do not satisfy specific requirements, coDatalogic distributor, supplying code samples, to obtain comple

    reading possibilities.

    3

  • 7/26/2019 Datalogic DS 4600 A

    46/59

    3.4 READING DIAGRAMS

    The following diagrams show the reading distance for barcdensities.

    DS4600A-210X (Long Range)

    4

    4

    12

    12

    16

    (in)

    0 4 20128 16

    0 100 200 300 400 500 600 700 800 900

    400

    300

    200

    100

    0

    100

    200

    300

    400

    (mm)

    24 28 32 36

    16

    8

    8

    0.50 mm (20 mils)0.60 mm (24 mils)0.80 mm (31 mils)1.00 mm (40 mils)

    NOTE: (0,0) is the center of the laser beam output window

    CONDITIONS:

    READING FEATURES

  • 7/26/2019 Datalogic DS 4600 A

    47/59

    DS4600A-200X (Medium Range)

    4

    2

    0

    2

    10

    8

    6

    4

    6

    (in)

    0 2 64 128 10 14 16 18

    0 50 100 150 200 250 300 350 400 450 50

    250

    200

    150

    100

    50

    0

    50

    100

    150

    200

    250

    (mm)

    2

    0.25 mm(10 mils)

    0.30 mm(12 mils)

    8

    10

    NOTE: (0,0) is the center of the laser beam output window

    CONDITIONS:

    Test Codes used = Interleaved 2/5 and Code 39

    3

  • 7/26/2019 Datalogic DS 4600 A

    48/59

    DS4600A-22XX (Short Range)

    2

    1

    0

    1

    5

    4

    3

    2

    3

    4

    5

    (in)

    0 1 32 64 5 7 8 9

    0 20 40 60 80 100 120 140 160 180 200 220 2

    120

    100

    80

    60

    40

    20

    0

    20

    40

    60

    80

    100

    120

    (mm)

    0.20 mm(8 mils)

    0.30 m(12 mi

    NOTE: (0,0) is the center of the laser beam output window

    CONDITIONS

    Code = Interleaved 2/5 or Code 39

    READING FEATURES

  • 7/26/2019 Datalogic DS 4600 A

    49/59

    DS4600A-22XX (Short Range)

    4

    2

    0

    2

    10

    8

    6

    4

    6

    8

    10

    (in)

    0 2 64 128 10 14 16

    0 40 80 120 160 200 240 280 320 360 400 44

    240

    200

    160

    120

    80

    40

    0

    40

    80

    120

    160

    200

    240

    (mm)

    0.50 mm(20 mils)

    NOTE: (0,0) is the center of the laser beam output window

    CONDITIONS

    Test Codes used = Interleaved 2/5 and Code 39

    3

  • 7/26/2019 Datalogic DS 4600 A

    50/59

    DS4600A-2X1X (Raster R1)

    4

    2

    0

    2

    10

    8

    6

    4

    6

    (in)

    0 2 64 128 10 14 16 18

    0 50 100 150 200 250 300 350 400 450 50

    250

    200

    150

    100

    50

    0

    50

    100

    150

    200

    250

    (mm)

    20

    0.25 mm(10 mils)

    0.30 mm(12 mils)

    8

    10

    NOTE: (0,0) is the center of the laser beam output window

    CONDITIONS:

    Test Codes used = Interleaved 2/5 and Code 39

    "Pitch" angle = 0

    "Sk " l 18

    READING FEATURES

  • 7/26/2019 Datalogic DS 4600 A

    51/59

    DS4600A-2X2X (Raster R2)

    4

    2

    0

    2

    10

    8

    6

    4

    6

    (in)

    0 2 64 128 10 14 16 18

    0 50 100 150 200 250 300 350 400 450 50

    250

    200

    150

    100

    50

    0

    50

    100

    150

    200

    250

    (mm)

    20

    0.25 mm(10 mils)

    0.30 mm(12 mils)

    8

    10

    NOTE: (0,0) is the center of the laser beam output window

    CONDITIONS:

    Test Codes used = Interleaved 2/5 and Code 39

    "Pitch" angle = 0

    "Sk " l 18

    3

  • 7/26/2019 Datalogic DS 4600 A

    52/59

    DS4600A-31XX (Long Range)

    4

    4

    12

    12

    16

    (in)

    0 4 20128 16

    0 100 200 300 400 500 600 700 800 900

    400

    300

    200

    100

    0

    100

    200

    300

    400

    (mm)

    24 28 32 36

    16

    8

    8

    0.50 mm (20 mils)0.60 mm (24 mils)0.80 mm (31 mils)

    1.00 mm (40 mils)

    NOTE: (0,0) is the center of the laser beam output window

    CONDITIONS:

    Test Codes used = Interleaved 2/5 and Code 39"Pitch" angle = 0

    "Skew" angle = 15

    "Tilt" angle = 0

    READING FEATURES

  • 7/26/2019 Datalogic DS 4600 A

    53/59

    DS4600A-30XX(Medium Range)

    4

    2

    0

    2

    10

    8

    6

    4

    6

    (in)

    0 2 64 128 10 14 16 18

    0 50 100 150 200 250 300 350 400 450 50

    250

    200

    150

    100

    50

    0

    50

    100

    150

    200

    250

    (mm)

    2

    0.25 mm(10 mils)

    0.30 mm(12 mils)

    8

    10

    NOTE: (0,0) is the center of the laser beam output window

    CONDITIONS:

    Test Codes used = Interleaved 2/5 and Code 39

    3

  • 7/26/2019 Datalogic DS 4600 A

    54/59

    DS4600A-32XX (Short Range)

    4

    2

    0

    2

    10

    8

    6

    4

    6

    8

    10

    (in)

    0 2 64 128 10 14 16

    0 40 80 120 160 200 240 280 320 360 400 44

    240

    200

    160

    120

    80

    40

    0

    40

    80

    120

    160

    200

    240

    (mm)

    0.20 mm(8 mils)

    NOTE: (0,0) is the center of the laser beam output window

    CONDITIONS

    Test Codes used = Interleaved 2/5 and Code 39

    MAINTENANCE

  • 7/26/2019 Datalogic DS 4600 A

    55/59

    4 MAINTENANCE

    4.1 CLEANING

    Clean the laser beam output window periodically for continued the reader.

    Dust, dirt, etc. on the window may alter the reading performance

    Repeat the operation frequently in particularly dirty environments

    Use soft material and alcohol to clean the window and substances.

    WARNING

    Clean the window of the DS4600A when the scaor, at least when the laser beam is deactivated.

    5

  • 7/26/2019 Datalogic DS 4600 A

    56/59

    5 TECHNICAL FEATURES

    ELECTRICAL FEATURES DS4600A-XXX0

    Power

    Supply Voltage 10 to 30 Vdc

    Power Consumption max. 6 W

    Serial InterfacesMain RS232, RS485 full-duplex, R

    (20 mA C.L. only with INT

    Auxiliary RS232

    Baudrates 1200 to 1152

    Inputs External Trigger, I

    (optocoupled NPN Voltage max. 30 Vdc

    Input Current max. 25 mA

    Outputs User-defined OUT1 a(optocoupled open emitter

    VCE max. 40 Vdc

    Collector Current max. 40 mA continuous; 130VCEsaturation 1V at 10 mA m

    Power Dissipation max. 90 mW at 40 C (Amb

    OPTICAL FEATURES

    Light Source Semiconductor las

    Wavelength (Note 1) 630 ~ 680 nSafety Class Class 2 EN60825-

    READING FEATURES (Note 2) 200X / 300X 210X / 310X

    Aperture Angle 66 70

    TECHNICAL FEATURES

  • 7/26/2019 Datalogic DS 4600 A

    57/59

    SOFTWARE FEATURES

    READABLE CODE SYMBOLOGIES

    EAN/UPC Code 93

    2/5 Interleaved Code 128

    Code 39 EAN 128

    Codabar Pharmacode

    Code Selection up to six codes during one

    Decoding Safety can enable multiple good Headers and Terminators up to four headers and fou

    Operating Modes ON LINE, AUTOMATIC, SERIA

    Configuration Modes through menus using W

    receiving commands fports (HOST MODE)

    Parameter Storage Non-volatile internal mem

    ENVIRONMENTAL FEATURES DS4600A-2XX0

    Operating temperature (Note 3) 0 to 40 C

    (32 to 104 F)

    Storage temperature -20 to 70 C (-4

    Humidity max. 90% non conVibration resistance IEC 68-2-6 test

    10 to 55 Hz; 2 hour

    Shock resistance IEC 68-2-27 tes

    11 ms; 3 shocks o

    Protection class IP65

    PHYSICAL FEATURESMechanical dimensions 101 x 83.5 x 42 mm (3.97

    Weight about 615 g. (22 oz.)

  • 7/26/2019 Datalogic DS 4600 A

    58/59

    DATALOGIC S.p.A.,

    Via Candini, 240012 - Lippo di Calderara

    Bologna - Italy

    dichiara chedeclares that thedclare que lebescheinigt, da das Gertdeclare que el

    DS4600A-XXXX Laser Scanner e tutti i suoi modelli

    and all its modelset tous ses modlesund seine modelley todos sus modelos

    sono conformi alle Direttive del Consiglio Europeo sottoelencate:are in conformity with the requirements of the European Council Directives listed below:sont conformes aux spcifications des Directives de l'Union Europenne ci-dessous:der nachstehend angefhrten Direktiven des Europischen Rats:cumple con los requisitos de las Directivas del Consejo Europeo, segn la lista siguiente:

    89/336/EEC EMC Directive e 92/31/EEC, 93/68/EEC emendamenti suand further amendmeet ses successifs aund spteren Abndey succesivas enmi

    Basate sulle legislazioni degli Stati membri in relazione alla compatibilit elettromagnetica ed allaOn the approximation of the laws of Member States relating to electromagnetic compatibility and Base sur la lgislation des Etates membres relative la compatibilit lectromagntique et la ber die Annherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Vertrentsprechen.

    Basado en la aproximacin de las leyes de los Pases Miembros respecto a la compatibilidad ede seguridad relativas al producto.

    Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti:This declaration is based upon compliance of the products to the following standards:Cette dclaration repose sur la conformit des produits aux normes suivantes:Diese Erklrung basiert darauf, da das Produkt den folgenden Normen entspricht:Esta declaracin se basa en el cumplimiento de los productos con las siguientes normas:

    EN 55022, August 1994: LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTINFORMATION TECHNOLOGY EQUIPMENT (ITE)

    EN 61000-6-2, April 1999: ELECTROMAGNETIC COMPATIBILITY (EMC).PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRI

  • 7/26/2019 Datalogic DS 4600 A

    59/59


Recommended