115
CONTENT Product group Günther GmbH · Temperaturmesstechnik 00 - TMT Thermocouples with a metal protection tube and a built-in thermocouple 05 - TKT Thermocouples with a ceramic protection tube and a built-in thermocouple 08 - TMP Straight thermocouples with a precious metal protective sleeve 10 - TMM Thermocouples with a metal protection tube and a built-in sheath measurement insert 12 - THD Welding-in thermocouples with D-sleeves 13 - TFL Thermocouples with blank flanges welded on 14 - TES Screw-in thermocouples 15 -TKM Thermocouples with a ceramic protection tube and a built-in sheath measurement insert 18 - TKL Micro-thermocouples and laboratory thermocouples 20 - TOM Sheath thermocouples without protection tube 30 - WTE Angle thermocouples with a bolted central angle 35 - WGG Angle thermocouples curved out of one segment Angle thermocouples with a welded together dip and carrier tube 50 - WMS Straight resistance thermometers with a metal protection tube and a built-in measurement insert 52 - WOS Sheath resistance thermometers without protection tube/thermowell 53 - WHD Weld in resistance thermometers with a D-type protective sleeve 54 - WFL Resistance thermometers with a welded on blank flange 55 - WES Screw-in resistance thermometers 60 - ESF Plug-in thermocouples or resistance thermometers with a bayonet nut connector 71 - KFT Cable sensors: thermocouple model 72 - KFW Cable sensors: resistance thermometer model 92 - THL Thermoelectric cables 93 - AGL Compensation cables 99 - EZT Individual components Messtechnik Schaffhausen GmbH Mühlenstrasse 4, CH- 8260 Stein am Rhein Telefon +41 52-672 50 00 Telefax +41 52-672 50 01 www.mts.ch, e-mail: [email protected] Messen Prüfen Automatisieren www.mts.ch MTS
Transcript
Page 1: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

CONTENT

Product group

Günther GmbH · Temperaturmesstechnik

00 - TMT Thermocouples with a metal protection tubeand a built-in thermocouple

05 - TKT Thermocouples with a ceramic protection tubeand a built-in thermocouple

08 - TMP Straight thermocouples with a preciousmetal protective sleeve

10 - TMM Thermocouples with a metal protection tubeand a built-in sheath measurement insert

12 - THD Welding-in thermocouples with D-sleeves

13 - TFL Thermocouples with blank flanges welded on

14 - TES Screw-in thermocouples

15 -TKM Thermocouples with a ceramic protection tubeand a built-in sheath measurement insert

18 - TKL Micro-thermocouples and laboratorythermocouples

20 - TOM Sheath thermocouples without protection tube

30 - WTE Angle thermocouples with a bolted central angle

35 - WGG Angle thermocouples curved out of one segmentAngle thermocouples with a welded together dipand carrier tube

50 - WMS Straight resistance thermometers with a metalprotection tube and a built-in measurement insert

52 - WOS Sheath resistance thermometerswithout protection tube/thermowell

53 - WHD Weld in resistance thermometers with a D-typeprotective sleeve

54 - WFL Resistance thermometers with a weldedon blank flange

55 - WES Screw-in resistance thermometers

60 - ESF Plug-in thermocouples or resistance thermometerswith a bayonet nut connector

71 - KFT Cable sensors: thermocouple model

72 - KFW Cable sensors: resistance thermometer model

92 - THL Thermoelectric cables

93 - AGL Compensation cables

99 - EZT Individual componentsMesstechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 2: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

00-TMT00 - TMT // Thermocouples with a metal thermowell and a built-in thermocouple

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 3: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Nominal length

Günther GmbH · Temperaturmesstechnik

00 - TMT // Thermocouples with a metal protection tube and a built-in thermocouple

Order sample:This list contains ready-to-install large and small straightthermocouples with built-in thermocouples.Sensors of this kind are used for standard temperaturemeasurements, mainly in liquid and gaseous media.The thermocouples listed are examples of those that can beordered.

Günther GmbH supplies any kind of standard straightthermocouple as well as special custom-made models.The number of possible combinations is virtually innumerable,depending on the dimensions, material, fastening, etc.The system of article numbers can be used to assemble thethermocouples in accordance with the respective operatingconditions.

The highest permissible operation temperature of a selectedthermocouple or of the protection tube material determinesthe maximum operation temperature of the thermocouple.

RepairsGünther GmbH carries out repairs on thermocouples and onresistance thermometers; however, high assembly costsfrequently make repairs uneconomical.

Thermoelectric voltages and limiting deviations of thethermocouples supplied by Günther GmbH comply withthe DIN EN 60584 norm.

The examples of products available for ordering shown inthis catalogue are a selection of appliances frequentlyused in practice. The numerical code indicated on theback of the individual components can be used to drawup the respective order number of a standard thermalsensor, although not all of the possible combinations ofnumbers and materials are useful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components requiretechnical clarification. Please contact us if any specificproblems concerning material and assembly occur duringuse. The many years of experience we have gained shouldenable us to find the best possible solution for your specificproblem.

1 x NiCr-Ni/K small straight thermocouple witha metal protection tube and a mounting thread

Product group: 00-TMTGünther Art. No.: 00-16006412-0710

Connection head: Type BProtection tube: ø 15 x 2 mm, material no. 1.4762Thermocouple: 1 x NiCr-Ni/K ø 2.0 mmNominal length: 710 mmFastening: G 3/4 A mounting thread, steel

Temperature range: 0 - 1100°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 00-TMT Page 1 of 3

Page 4: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Nominal lengthNominal length

Günther GmbH · Temperaturmesstechnik

00 - TMT // Thermocouples with a metal protection tube and a built-in thermocouple

More order samples:

2 x NiCr-Ni/K small straight thermocouple withan open metal protection tube and a mounting thread

1 x NiCr-Ni/K large straight thermocouplewith a metal protection tube, no fastening

Product group: 00-TMTGünther Art. No.: 00-26001410-1000

Connection head: Type AProtection tube: ø 22 x 2 mm, material no. 1.4762Thermocouple: 1 x NiCr-Ni/K ø 3.0 mmNominal length: 1000 mmFastening: None

Temperature range: 0 - 1100°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in the catalogueunder 99-EZT.

Product group: 00-TMTGünther Art. No.: 00-99000006-0500

Connection head: Type BProtection tube: ø 15 x 2 mm, material no. 1.4841

perforatedThermocouple: 2 x NiCr-Ni/K ø 2.0 mmNominal length: 500 mmFastening: G 1/2 A mounting thread, steel, zinc-coated

Temperature range: 0 - 1100°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Feature: Gasproof connection head

Edition english 002 Product group 00-TMT Page 2 of 3

Page 5: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Nominal length

Nominal length

00 - TMT // Thermocouples with a metal protection tube and a built-in thermocouple

More order samples:

2 x PtRh10-Pt/S double thermocouple with a Type A connectionhead and steel mounting thread, protection tube material 1.476222 x 2 mm, with a tapered sensor tip, ø 10 mm

2 x PtRh30-PtRh6/B double thermocouple with a TypeAUZH connection head for measuring transducer,protection tube material 2.4816 Inconel 22 x 2 mm

Product group: 00-TMTGünther Art. No.: 00-26251232-1850

Connection head: Type AProtection tube: ø 22 x 2 mm, material no. 1.4762Inner tube 1: ø 15 x 11 mm, C610Inner tube 2: ø 6 x 4 mm, C799Insulation rod: ø 3.5 mm, 4-hole, C799Thermocouple: 2 x PtRh10-Pt/S ø 0.5 mmNominal length: 1850 mmFastening: G 1 A mounting thread, steelSensor tip: Tapered, ø 10 x 60 mmTemperaturesmeasured: 0 - 1100°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Product group: 00-TMTGünther Art. No.: 00-28204342-2000

Connection head: Type AUZHProtection tube: 2.4816 Inconel ø 22 x 2 mmInner tube: ø 15 x 11 mm, C799Insulation rod: ø 8.5 mm, 5-hole, testable, C799Thermocouple: 2 x PtRh30-PtRh6/B ø 0.5 mmNominal length: 2000 mmFastening: G 1 A mounting thread, steel,

for ø 25.8 mmTemperaturesmeasured: 0 - 1200°CLimiting deviation: Class 2 acc. to DIN EN 60584-2

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in the catalogueunder 99-EZT.

Günther GmbH · Temperaturmesstechnik

Edition english 002 Product group 00-TMT Page 3 of 3

Page 6: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Protection tube (material)St 35.8 Mat. no. 1.0305 1Kanthal AF 2Stainless steel Mat. no. 1.4301 3Stainless steel Mat. no. 1.4571 4X18Cr N 28 Mat. no. 1.4749 5X10Cr Al 24 Mat. no. 1.4762 6X15CrNi Si 25 20 Mat. no. 1.4841 7Inconel Mat. no. 2.4816 8Heat-res. steel Mat. no. 1.4893 9

Fastening None 0Stop flange 1Mounting thread 2Flange/counter flange 3

Thermocouple Type R PtRh13-Pt 1Type S PtRh10-Pt 2Type B PtRh30-PtRh6 3Type K NiCr-Ni 4Type J Fe-CuNi 5Type L Fe-CuNi 6Type C WRe5-WRe26 7Type N Nicrosil-Nisil 8Type D WRe3-WRe25 9

Protection tube (dimensions)Special sizes:

15 x 2 mm 1 12 x 1.5 mm 522 x 2 mm 2 15 x 1.3 mm 624 x 3 mm 3 11 x 1.5 mm 726 x 4 mm 4 10 x 1.5 mm 8

9 x 1 mm 9

ThermocoupleStandard 1 Standard (testable) 2Double 3 Double (testable) 4Triple 5

HeadA 1 B 6AUS 2 BUS 7AUZ 3 BUZ 8AUZH 4 BUZH 9AUSH 5 BBK 0

Sensor point

Not tapered 0 Tapered to 10 mm 5Tapered to 15 mm 1 Tapered to 8 mm 6Tapered to 12 mm 2Tapered to 9 mm 3Tapered to 6 mm 4 Tapered, other 9

Inner tube None 0C610 gastight ceramic 1C799 Aluminium oxide 2

Custom designs: 0 0 - 9 9 0 0 x x x x -

Consecutive no. Nominal length / mm

00 - TMT // Thermocouples with a metal protection tube and a built-in thermocouple

Metal protection tube + thermocouple 0 0 - -

Nominal length / mm

Page 7: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

05 - TKT // Thermocouples with a ceramic protection tube and a built-in thermocouple

05-TKT

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 8: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

05 - TKT // Thermocouples with a ceramic protection tube and a built-in thermocouple

Order sample:The 05 product group comprises ready-to-install large andsmall straight thermocouples with ceramic protection tubes andbuilt-in thermocouples. The elements are used for technicaltemperature measurements for temperatures ranging from 200°Cto 1800°C at pressures of max. one bar.

Günther GmbH supplies any kind of standard straightthermocouple as well as special custom-made models.

The highest permissible operation temperature of a selectedthermocouple or of the protection tube material determinesthe maximum operation temperature of the thermocouple.

The service life of the thermocouples can be increased ifa gasproof ceramic inner tube is installed in addition to theprotection tube.

Properties of the most widely-used types of ceramic materialsfor protection tubes and inner tubes:

C799 aluminium oxideGasproof, highly fire-resistant, 99.7%maximum operation temperature of 1800°C

C610 gastight ceramicGasproof, high aluminium oxide content > 60%,maximum operation temperature of 1450°C

C530 porous ceramic materialNot gasproof, medium-fine structure, resistant to temperaturechange, high aluminium oxide content, maximum operationtemperature of 1500°C

The examples of products available for ordering shown inthis catalogue are a selection of appliances frequently usedin practice. The numerical code indicated on the back of theindividual components can be used to draw up the respectiveorder number of a standard thermal sensor, although not allof the possible combinations of numbers and materials areuseful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components require technicalclarification. Please contact us if any specific problemsconcerning material and assembly occur during use. Themany years of experience we have gained should enable usto find the best possible solution for your specific problem.

1 x PtRh10-Pt/S thermocouple with a Type A connectionhead and flange, C610 ceramic protection tube, steelholding tube

Product group: 05-TKTGünther Art. No.: 05-62211211-1000

Connection head: Type AHolding tube: ø 32 x 2 x 200 mm, material no. 1.0305Protection tube: ø 24 x 19 mm, C610Inner tube: ø 15 x 11 mm, C610Insulation rod: ø 8.5 mm, 2-hole, C610Thermocouple: 1 x PtRh10-Pt/S ø 0.5 mmNominal length: 1000 mmFastening: DIN 43734 stop flange

Temperature range: 0 - 1450°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 05-TKT Page 1 of 3

Nominal length

Page 9: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

05 - TKT // Thermocouples with a ceramic protection tube and a built-in thermocouple

More order samples:

2 x PtRh30-PtRh6/B thermocouple with a Type B connection headand a ceramic protection tube as well as a gasproof mounting thread

2 x PtRh10-Pt/S thermocouple with a connection headType AUZH, C530 ceramic protection tube

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in the catalogueunder 99-EZT.

Product group: 05-TKTGünther Art. No.: 05-82214230-0710

Connection head: Type AUZHHolding tube: ø 32 x 2 x 200 mm, material no. 1.0305Protection tube: ø 26 x 18 mm, C530Inner tube: ø 15 x 11 mm, C610Insulation rod: ø 8.5 mm, C610Thermocouple: 2 x PtRh10-Pt/S ø 0.5 mmNominal length: 710 mmFastening: None

Temperature range: 0 - 1450°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2Feature: Measuring transducer installed

in the connecting head

Product group: 05-TKTGünther Art. No.: 05-20086332-0600

Connection head: Type BHolding tube: ø 15 x 2 x 100 mm, material no. 1.0305Protection tube: ø 10 x 6 mm, C799, gastightInner tube: NoneInsulation rod: ø 5.5 mm, 4-hole, C799Thermocouple: 2 x PtRh30-PtRh6/B ø 0.5 mmNominal length: 600 mmFastening: G 3/4 A mounting thread, steel, gasproof

Temperature range: 0 - 1700°C

Limiting deviation: Class 2 acc. to DIN EN 60584-2

Edition english 002 Product group 05-TKT Page 2 of 3

Nominal length

Nominal length

Page 10: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

05 - TKT // Thermocouples with a ceramic protection tube and a built-in thermocouple

More order samples:

3 x PtRh10-Pt/S triple vacuum thermocouple, witha Type A connection head and a DN 20 vacuum flange

1 x PtRh10-Pt/S single-vacuum thermocouple, testable,with a Type AUZ connection head and a DN 20 vacuumflange

Product group: 05-TKTGünther Art. No.: 05-99050013-0500

Connection head: Type AHolding tube: ø 22 x 2 x 100 mm, material no. 1.0305,

with a vacuum flange welded onProtection tube: ø 15 x 10 mm, C530Inner tube: ø 8 x 6 mm, C799Insulation rod: ø 5.5 mm, 6-hole, C799Thermocouple: 3 x PtRh10-Pt/S ø 0.5 mmInstallation length: 500 mmFastening: DN 20 vacuum flange acc. to DIN 28403Feature: Holding tube in the head, gasproof,

moulded

Temperature range: 0 - 1300°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Product group: 05-TKTGünther Art. No.: 05-99050216-0500

Connection head: Type AUZHolding tube: ø 22 x 2 x 80 mm, material no. 1.4571Protection tube 1: ø 7 x 5 mm, C799Protection tube 2: ø 6 x 4 mm, C799 for test thermal elementInner tube: NoneInsulating stem: ø 4.0 mm, 4-hole, C799

Installed in protection tube 1

Thermocouple: 1 x PtRh10-Pt/S ø 0.5 mmInstallation length: 500 mmFastening: DN 20 vacuum flange acc. to DIN 28403

Temperature range: 0 - 1400°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in the catalogueunder 99-EZT.

Edition english 002 Product group 05-TKT Page 3 of 3

Installation lengthInstallation length

Page 11: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Protection tube 10 x 7 mm C610 1(dimensions / 10 x 6 mm C799 2material) 15 x 11 mm C610 3

15 x 10 mm C799 416 x 12 mm C610 524 x 19 mm C610 624 x 18 mm C799 726 x 18 mm C530 816 x 12 mm C799 9

Inner tube None 0C530 Porous ceramic material (on request) 1C610 gastight ceramic 2C799 Aluminium oxide 3

Thermocouple Standard 1 Standard (testable) 2Double 3 Double (testable) 4Triple 5

Head A 1 B 6AUS 2 BUS 7AUZ 3 BUZ 8AUZH 4 BUZH 9AUSH 5 BBK 0

Custom designs: 0 5 - 9 9 0 5 x x x x -

Consecutive no. Nominal length / mm

05 - TKT // Thermocouples with a ceramic protection tube and a built-in thermocouple

Ceramic protection tube + thermocouple 0 5 - -

Nominal length / mm

Holding tube(visible length) 1.0305 1.4571 1.4762 1.4841

15x 2 50 mm 05 75 - -15 x 2 60 mm 06 76 26 3615 x 2 80 mm 07 77 27 3715 x 2 100 mm 08 78 28 3815 x 2 150 mm 09 79 29 3915 x 2 200 mm 10 80 30 4022 x 2 100 mm 11 81 31 4122 x 2 150 mm 12 82 32 4222 x 2 200 mm 13 83 33 4322 x 2 250 mm 14 84 34 4422 x 2 300 mm 15 85 35 4528.3 x 1.5 80 mm 16 - - -28.3 x 1.5 180 mm 17 - - -32 x 2 50 mm 18 88 - 4832 x 2 100 mm 19 89 - 4932 x 2 150 mm 20 90 - 7032 x 2 200 mm 21 91 - 7132 x 2 250 mm 22 92 - 72

Alloy 600 (mat. no. 2.4816) Kanthal22 x 2 200 mm 61 15 x 1.3 100 mm 5122 x 2 300 mm 62 15 x 1.3 150 mm 5222 x 2 400 mm 63 15 x 1.3 200 mm 5322 x 2 500 mm 6430 x 2.5 230 mm 65 Individual 0030 x 2.5 400 mm 66 No holding tube 99

Fastening None 0Stop flange 1Mounting thread 2Flange/counter flange 3

Thermocouple Type R PtRh13-Pt 1Type S PtRh10-Pt 2Type B PtRh30-PtRh6 3Type K NiCr-Ni 4Type J Fe-CuNi 5Type L Fe-CuNi 6Type C WRe5-WRe26 7Type N Nicrosil-Nisil 8Type D WRe3-WRe25 9

Page 12: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

08 - TMP // Straight thermocouples with a precious metal protective sleeve

08-TMP

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 13: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Nominal length

Günther GmbH · Temperaturmesstechnik

08 - TMP // Straight thermocouples with a precious metal protective sleeve

Order sample:The 08-TMP catalogue section contains high-temperaturethermocouples with precious metal protective sleeves and preciousmetal thermocouples. Sensors of this kind are used in high-temperature furnaces and plants, particularly for measuring thetemperature of molten materials in the glass industry.

Günther GmbH supplies standard straight thermocouples withprotective sleeves made of platinum rhodium or with platinumcoatings as well as special custom-made models.

The highest permissible operation temperature of a selectedthermocouple or of the protection tube material determines themaximum operation temperature of the thermocouple.

Limiting deviations of the thermoelectric voltages comply withDIN EN 60584-2 Class 1 for Types S and R and Class 2 forType B.

The useful life span of thermocouples is increased when:

Wire of a diameter of 0.5 mm is usedTop-quality ceramic material (C799) is usedAn additional inner tube is installed

Properties of the most widely-used types of ceramicmaterials for protection tubes and inner tubes:

C799 aluminium oxideGastight, highly fire-resistant, Al203 content of 99.7%Maximum operation temperature: 1800°C

C610 gastight ceramicGastight, high aluminium oxide content > 60%Maximum operation temperature: 1450°C

C530 porous ceramic materialNot gastight, medium-fine structureResistant to temperature changeHigh aluminium oxide contentMaximum operation temperature: 1500°C

Operation temperatures for precious metal thermocouples:

Type Diameter Max. temp

S,R 0.35 mm 1350°CB 0.35 mm 1600°CS,R 0.5 mm 1600°CB 0.5 mm 1800°C

1 x PtRh10-Pt/S standard thermocouple with a Type Aconnection head, C799 16 x 12 mm ceramic protectiontube and a PtRh protective sleeve.

Product group: 08-TMPGünther Art. No.: 08-93321461-0960/0095

Connection head: Type AHolding tube: ø 22 x 2 x 150 mm, material no. 1.4762Protection tube: ø 16 x 12 mm, C799Inner tube: ø 8 x 5 mm, C799Insulation rod: ø 4.5 mm, 2-hole, C799Protective sleeve: PtRh 80/20 ø 9.1 x 0.5 x 95 mmThermocouple: 1 x PtRh10-Pt/S ø 0.5 mmNominal length: 960 mmFastening: DIN 43734 stop flangeTemperature range: 0 - 1500°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 08-TMP Page 1 of 3

Page 14: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Nominal length

Nominal length

Günther GmbH · Temperaturmesstechnik

08 - TMP // Straight thermocouples with a precious metal protective sleeve

More order samples:

3 x PtRh10-Pt/S triple thermocouple, protection tube coatedwith platinum at the lower end

1 x PtRh10-Pt/S standard element with a stainless steelshaft tube and replaceable precious metal protectivesleeves

Product group: 08-TMPGünther Art. No.: 08-99080018-0950/0200

Connection head: Type AProtection tube: ø 17.5 x 12.5 mm x 750 mm, C799Inner tube: ø 10 x 6 mm, C799Insulation rod: ø 4.5 mm, 6-hole, C799Holding tube: ø 26.67 x 22.4 x 150 mm, material no. 1.4571Thermocouple: 3 x PtRh10-Pt/S ø 0.5 mmMeasuring point 1: C = 20 mmMeasuring point 2: B = 76 mmMeasuring point 3: A = 116 mmNominal length: 950 mmFastening: NoneSensor tip: Platinum-coated, length: 200 mmTemperature range: 0 - 1500°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in the catalogueunder 99-EZT.

Product group: 08-TMPGünther Art. No.: 08-99080004-0710/0100

Connection head: Type AShaft tube (SR): ø 15 x 3 mm, material no. 1.4571Inner tube: ø 8 x 5 mm, C799Insulation rod: ø 4.0 mm, 2-hole, C799Holding tube: ø 28.3 x 1.5 x 35 mm, material no. 1.0305Thermocouple: 1 x PtRh10-Pt/S ø 0.5 mmNominal length: 710 mmFastening: DIN 43734 stop flangePtRh protective sleeve: ø 9.1 x 0.5 x 100 mm PtRh90/10Feature: Protective sleeve replaceable

with M14 x 1.5 knurled nut,material no. 2.4816

Temperature range: 0 - 1500°C, momentary 1600°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 08-TMP Page 2 of 3

Page 15: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Nominal length

Nominal length

Günther GmbH · Temperaturmesstechnik

Product group: 08-TMPGünther Art. No.: 08-99080058-1450/0200

Connection head: Type AHolding tube: ø 22 x 2 x 200 mm, material no. 1.0305Protection tube: ø 15 x 10 mm, C799Inner tube: NoneInsulation rod: ø 8.5 mm, 6-hole, C799Thermocouple: 3 x PtRh30-PtRh6/B ø 0.5 mmNominal length: 1450 mmPtRh protective sleeve: ø 15.5 x 0.2 x 200 mm, made of PtRh90/10,

fastened onto the protection tube with puttyFastening: DIN 43734 stop flangeMeasuring points: 0 - 80 - 160 mm

Temperature range: 0 - 1500°CLimiting deviation: Class 2 acc. to DIN EN 60584-2

08 - TMP // Straight thermocouples with a precious metal protective sleeve

More order samples:

2xPtRh30-PtRh6/B double thermocouple with a Type B connectionhead and a PtRh protective sleeve adhered to the protection tube

3xPtRh30-PtRh6/B triple thermocouple witha PtRh protective sleeve applied

Product group: 08-TMPGünther Art. No.: 08-20076832-0800/0050

Connection head: Type BHolding tube: ø 15 x 2 x 80 mm, material no. 1.0305Protection tube: ø 10 x 6 mm, C799Inner tube: NoneInsulation rod: ø 5.5 mm, 4-hole, C799Thermocouple: 2 x PtRh30-PtRh6/B ø 0.5 mmNominal length: 800 mmPtRh protective sleeve: ø 6.5 x 0.5 x 75 mm made of PtRh90/10

50 mm protruding from the protection tubeFastening: G 1/2 A mounting thread, steel, zinc-coated

Temperature range: 0 - 1500°CLimiting deviation: Class 2 acc. to DIN EN 60584-2

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Edition english 002 Product group 08-TMP Page 3 of 3

Page 16: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Fastening None 0 Mounting thread 2Flange 1 Flange/counter flange 3

Holding tube (visible length) 1.0305 1.4571 1.4762 1.4841

15x 2 50 mm 05 75 - -15 x 2 60 mm 06 76 26 3615 x 2 80 mm 07 77 27 3715 x 2 100 mm 08 78 28 3815 x 2 150 mm 09 79 29 3915 x 2 200 mm 10 80 30 4022 x 2 100 mm 11 81 31 4122 x 2 150 mm 12 82 32 4222 x 2 200 mm 13 83 33 4322 x 2 250 mm 14 84 34 4422 x 2 300 mm 15 85 35 4528.3 x 1.5 80 mm 16 - - -28.3 x 1.5 180 mm 17 - - -32 x 2 50 mm 18 88 - 4832 x 2 100 mm 19 89 - 4932 x 2 150 mm 20 90 - 7032 x 2 200 mm 21 91 - 7132 x 2 250 mm 22 92 - 72Alloy 600 (mat. no. 2.4816) Kanthal22 x 2 200 mm 61 15 x 1.3 100 mm 5122 x 2 300 mm 62 15 x 1.3 150 mm 5222 x 2 400 mm 63 15 x 1.3 200 mm 5322 x 2 500 mm 6430 x 2.5 230 mm 65 Individual 0030 x 2.5 400 mm 66 No holding tube 99

Head A 1 B 6AUS 2 BUS 7AUZ 3 BUZ 8AUZH 4 BUZH 9AUSH 5 BBK 0

Thermocouple Type R 1x PtRh13-Pt Standard 1Type R 2x PtRh13-Pt Double 2Type R 3x PtRh13-Pt Triple 3Type S 1x PtRh10-Pt Standard 4Type S 2x PtRh10-Pt Double 5Type S 3x PtRh10-Pt Triple 6Type B 1x PtRh30-PtRh6 Standard 7Type B 2x PtRh30-PtRh6 Double 8Type B 3x PtRh30-PtRh6 Triple 9

Inner tube None 0C530 Porous ceramic material (on request) 1C610 gastight ceramic 2C799 Aluminium oxide 3

Protection tube 7 x 4 mm C799 0(dimensions / 10 x 7 mm C610 1material) 10 x 6 mm C799 2

15 x 11 mm C610 315 x 10 mm C799 416 x 12 mm C610 524 x 19 mm C610 624 x 18 mm C799 716 x 12 mm C530 816 x 12 mm C799 9

Custom designs: 0 8 - 9 9 0 8 x x x x -

Consecutive no. Nominal length / mm

08 - TMP // Straight thermocouples with a precious metal protective sleeve

0 8 - -

Nominal length Visible length of the PtRh protective sleeve

Protective sleeves PtRh90/10 9.1 x 0.3 mm 1PtRh90/10 9.1 x 0.5 mm 2PtRh90/10 6.5 x 0.5 mm 3PtRh90/10 9.0 x 0.8 mm 4PtRh85/15 7.3 x 0.4 mm 5PtRh80/20 9.1 x 0.5 mm 6PtRh90/10 9.0 x 0.5 mm 7Other 9

Thermocouples withPtRh protective sleeves

Page 17: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

10 - TMM // Thermocouples with a metal thermowell and a built-in sheath measurement insert

10-TMM

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 18: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

10 - TMM // Thermocouples with a metal protection tube and a built-in sheath measurement insert

Order sample:This product group comprises ready-to-install large and smallstraight thermocouples with built-in sheath measurementinserts. Sensors of this type are used for standard temperaturemeasurements, primarily in liquid and gaseous media.The thermocouples listed are examples of those that can beordered.

Günther GmbH supplies any kind of standard straight thermo-couple as well as special custom-made models. The number ofpossible combinations is virtually innumerable, depending on thedimensions, material, fastening, etc. The system of article numberscan be used to assemble the thermocouples in accordance withthe respective operating conditions.

The main difference between thermocouples with thermocouplesinsulated in ceramic material (product group 00-TMT) andthermocouples with sheath measurement inserts is that in thecase of the latter the thermoelectric wires (internal conductors)are protected by a metal sheath – usually made of Alloy 600 –which may serve to increase the service life.

Unlike thermocouples, sheath measurement inserts are easy toreplace.

Thermoelectric voltages and limiting deviations of the sheathedthermocouples supplied by Günther GmbH comply either withthe DIN 43710 norm or with the DIN EN 60584 norm.

The examples of products available for ordering shown inthis catalogue are a selection of appliances frequently usedin practice. The numerical code indicated on the back of theindividual components can be used to draw up the respectiveorder number of a standard thermal sensor, although not allof the possible combinations of numbers and materials areuseful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components require technicalclarification. Please contact us if any specific problemsconcerning material and assembly occur during use. Themany years of experience we have gained should enable usto find the best possible solution for your specific problem.

1 x NiCr-Ni/K thermocouple with a Type Bconnection head and a G 3/4 A mounting thread

Product group: 10-TMMGünther Art. No.: 10-11046632-0750

Connection head: Type BProtection tube: ø 15 x 3 mm, material no. 1.0305Measurement insert: 1 x NiCr-Ni/K ø 4.5 mmNominal length: 750 mmFastening: 3/4 A mounting thread, steelSensor tip: Tapered, stainless steel, ø 6 x 60 mmTemperature range: 0 - 600°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 10-TMM Page 1 of 3

Nominal length

Installationlength

Page 19: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

10 - TMM // Thermocouples with a metal protection tube and a built-in sheath measurement insert

More order samples:

1 x Fe-CuNi/J thermocouple with a Type AUZH connection head anda mounting thread

1 x NiCr-Ni/K standard thermocouple with a connectionhead Type A and flange (testable model)

Product group: 10-TMMGünther Art. No.: 10-24004832-0600

Connection head: Type AUZHProtection tube: ø 22 x 2 mm, material no. 1.4571Measurement insert: 1 x Fe-CuNi/J ø 6.0 mmNominal length: 600 mmFastening: G 1 A gasproof mounting threadFeature: Measuring transducer fitted in the head,

4..20 mA equivalent to 0-800°C

Temperature range: 0 - 800°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Product group: 10-TMMGünther Art. No.: 00-26201731-1300

Connection head: Type AProtection tube: ø 22 x 2 mm, material no. 1.4762Inner tube: ø 15 x 11 mm, C610Measurement insert: 11 x NiCr-Ni/K ø 6.0 mm

with a ø 3.5 mm boreholeNominal length: 1300 mmFastening: DIN 43734 stop flange

Temperature range: 0 - 1200°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 10-TMM Page 2 of 3

Nominal length

Nominal length

Page 20: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Product group: 10-TMTGünther Art. No.: 10-99100035-2000

Connection head: Type BHolding tube: ø 15 x 2 x 500 mm, material no. 1.4841Inner tube: NoneMeasurement insert: 1 x NiCr-Ni/K ø 3.0 mm, sheath made

of Alloy 600Nominal length: 2000 mmFastening: G 1/2 A mounting thread, steel,

zinc-coatedTemperature range: 0 - 1000°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Feature: Measurement insert protrudes freely fromthe holding tube and is adhered intothe tube

10 - TMM // Thermocouples with a metal protection tube and a built-in sheath measurement insert

More order samples:

1 x NiCr-Ni/K thermocouple with a Type AUZH connection headand a fitted measuring transducer

1 x NiCr-Ni/K thermocouple with a Type B connection headand a freely-protruding sensor

Product group: 10-TMTGünther Art. No.: 10-99100060-0700

Connection head: Type AUZH with a measuring transducerProtection tube: ø 15 x 2 mm, material no. 1.4841

650 mm longHolding tube: ø 22 x 2 x 80 mm, material no. 1.4571Measurement insert: 1 x NiCr-Ni/K ø 6.0 mm,

installation length = 745 mmNominal length: 700 mmFastening: G 3/4 A gasproof mounting thread

G1 A - G 3/4 I reducing couplingSensor tip: Sheath measurement insert 50 mm

freely protruding (resilient)Measuring transducer: Temperature straight, 4 - 20 mA

equivalent 0 - 1000°CTemperature range: 0 - 1000°CLimiting deviation: Class 1 acc. to DIN EN 60584-2Feature: Sheath measurement insert with

resilient installation, sealed at the connection head

Edition english 002 Product group 10-TMM Page 3 of 3

Installation length

Nominal length

Page 21: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Head A 1 B 6AUS 2 BUS 7AUZ 3 BUZ 8AUZH 4 BUZH 9AUSH 5 BBK 0

Fastening None 0Stop flange 1Mounting thread 2Flange/counter flange 3

Protection tube St 35.8 Mat. no. 1.0305 1(Material) Kanthal AF 2

Stainless steel Mat. no. 1.4301 3Stainless steel Mat. no. 1.4571 4X18CrN 28 Mat. no. 1.4749 5X10CrAl 24 Mat. no. 1.4762 6X15CrNiSi 25 20 Mat. no. 1.4841 7Alloy 600 Mat. no. 2.4816 8Heat-res. steel Mat. no. 1.4893 9

Inner tube None 0C530 Porous ceramic material 1C610 Porcelain 2C799 Aluminium oxide 3

Sheath element (type/number of thermocouples/sheath material/diameter/verifiability)

NiCr-Ni /K Alloy 600 2.4816 Fe-CuNi/L 1.4541 Fe-CuNi/J 1.4541

ø / mm1.5 25 26 27 28 - 29 30 31 32 33 34 35 362 37 38 39 40 - 41 42 43 44 45 46 47 483 49 50 51 52 90 53 54 55 56 57 58 59 604.5 61 62 63 64 91 65 66 67 68 69 70 71 726 73 74 75 76 92 77 78 79 80 81 82 83 848 85 86 87 88 93 - - - - - - - -

Sta

ndar

d, te

stab

le

Do

uble

, tes

tab

le

Sta

ndar

d

Do

uble

Trip

le

Sta

ndar

d, te

stab

le

Do

uble

, tes

tab

le

Sta

ndar

d

Do

uble

Sta

ndar

d, te

stab

le

Do

uble

, tes

tab

le

Sta

ndar

d

Do

uble

Protection tube (dimensions)Special sizes:

15 x 2 mm 1 12 x 1.5 mm 522 x 2 mm 2 15 x 1.3 mm 624 x 3 mm 3 11 x 1.5 mm 726 x 4 mm 4 10 x 1.5 mm 8

9 x 1 mm 9

Custom designs: 1 0 - 9 9 1 0 x x x x -

Consecutive no. Nominal length / mm

10 - TMM // Thermocouples with a metal protection tube and a built-in sheath measurement insert

Metal protection tube + sheath 1 0 - -

Nominal length / mm

Sensor point

Not tapered 0 Tapered to 10 mm 5Tapered to 15 mm 1 Tapered to 8 mm 6Tapered to 12 mm 2Tapered to 9 mm 3Tapered to 6 mm 4 Tapered other 9

Sta

ndar

d, te

stab

le

Do

uble

, tes

tab

le

Sta

ndar

d

Do

uble

10 11 12 1314 15 16 1718 19 20 2122 23 24 9495 96 97 98

- - - -

Nicrosil-Nisil/N 2.4816

Page 22: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

12 - THD // Welding-in thermocouples with D-sleeves

12-THD

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 23: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Welding-in thermocouples are used for measuring temperaturesin gaseous and in liquid media such as air, steam, water, oil, etc.at high flow velocities and high pressures.Special welding sleeves are suitable for pressures of up to 700 bar.The fittings of this assembly are equipped with replaceable sheathmeasurement inserts.The most significant component is a protective sleeve made of high-quality, solid metallic material which is welded into the respectivesystem. In this case the protective sleeve and the system should bemade of the same material.Available space at the place of use and stress levels to be expectedwill determine the choice of the most suitable protective sleeve.The service life of the protective sleeve depends of numerous factorssuch as temperature, pressure, the respective medium for use,installation position (vertical/horizontal), thermowell material and theincoming flow relationship.

Guidelines for the working stability of the protective sleeves interms of pressure and temperature can be seen in the DIN 43772diagrams.It is particularly the question of chemical stability that willneed to be checked on carefully for each individual situation.Frequently it is only after operation tests have been carriedout that information is gained, since even minor impurities inthe surrounding media can have a considerable effect on thebehaviour of the protective sleeves.

Most suitable areas of application:

Containers and pipings

Apparatus and machines

Laboratories

Test ranges

Process technology

Energy production and heat distribution

Food and beverages production

Machine and plant construction

The examples of products available for ordering shown inthis catalogue are a selection of appliances frequently usedin practice. The numerical code indicated on the back of theindividual components can be used to draw up the respectiveorder number of a standard thermal sensor, although not allof the possible combinations of numbers and materials areuseful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components require technicalclarification. Please contact us if any specific problemsconcerning material and assembly occur during use. Themany years of experience we have gained should enableus to find the best possible solution for your specific problem.

Günther GmbH · Temperaturmesstechnik

12 - THD // Welding-in thermocouples with D-sleeves

1 x NiCr-Ni/K welding-in thermocouple with a Type Bconnection head, M18 x 1.5 connection thread and a D2welding sleeve

Product group: 12-THDGünther Art. No.: 12-10022107-0200/0140

Connection head: Type B (M24 x 1.5)Protection tube: D2 welding sleeve, mat. no. 1.4571Neck pipe: ø 11 x 2 x 140 mm, material no. 1.4571Measuring insert: 1 x NiCr-Ni/K ø 6.0 mmThermowell length: 200 mmFastening: None

Temperature range: 0 - 400°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Order sample:

Edition english 002 Product group 12-THD Page 1 of 2

Neck pipe length

Shaft length

Cone length

Thermowell length

Page 24: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

12 - THD // Welding-in thermocouples with D-sleeves

Order sample:

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

1 x Fe-CuNi/J welding-in thermocouple with a Type BUZconnection head and replaceable measuring insertas well as a sleeve made of stainless steel

Product group: 12-THDGünther Art. No.: 12-99120015-0070/0080

Connection head: Type BUZ (M24 x 1.5)Protection tube: Welding sleeve with M14 x1.5 female thread,

mat. no. 1.4571, overall length = 70 mm,cone length = 25 mm

Neck pipe: ø 11 x 1 x 80 mm, material no. 1.4571, M14 x 1.5Measuring insert: 1 x Fe-CuNi/J ø 6.0 mmThermowell length: 70 mm

Temperature range: 0 - 400°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

2 x NiCr-Ni/K thermocouple with a Type BUZH connectionhead and a replaceable measuring transducer

Product group: 12-THDGünther Art. No.: 12-70020017-0325/0140

Connection head: Type BUZH (M24 x 1.5)Neck tube: 11 x 2 mm, material no. 1.4571Measuring insert: 2 x NiCr-Ni/K ø 6.0 mm, sheath made

of Alloy 600Installation length: 325 mmNeck pipe length: 140 mmFastening: M18x1.5 screw socketSensor tip: Sheath measuring insert freely protrudingTemperatures: 0 - 800°CMeasuring transducer: Günther PCP 4...20 mALimiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 12-THD Page 2 of 2

Neck pipe length

Thermowell length

Neck pipe length

Installation length

Page 25: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Welding-in protection tubes in acc. with DIN 43763

D1 Cone length = 65 mm, Shaft length = 50 mm, Thermowell length = 140 mm, ø 24 mm 10 20 30D2 Cone length = 125 mm, Shaft length = 50 mm, Thermowell length = 200 mm, ø 24 mm 11 21 31D4 Cone length = 65 mm, Shaft length = 110 mm, Thermowell length = 200mm, ø 24 mm 12 22 32D5 Cone length = 125 mm, Shaft length = 110 mm, Thermowell length = 260 mm, ø 24 mm 13 23 33

DS Cone length = 65 mm, Shaft length = 50 mm, Thermowell length = 140 mm, ø 18 mm 15 25 35DS Cone length = 40 mm, Shaft length = 50 mm, Thermowell length = 115 mm, ø 18 mm 16 26 36No thermowell (sheath freely protruding) 00Other 99

1.73

35

1.45

71

1.54

15

Neck tube in acc. with DIN 43767

With M24 x 1.5 / M18 x 1.5 screw fittings, galvanised steel 1With M24 x 1.5 / M18 x 1.5 screw fittings, stainless steel 2With M24 x 1.5 / M14 x 1.5 screw fittings, galvanised steel 3With M24 x 1.5 / M14 x 1.5 screw fittings, stainless steel 4

None 0

Other 9

Blank flange St37-2 1.4571 C22.8in acc. with DIN 2527

DN 10 PN 16 1 0 2 0 3 0 NoneDN 15 PN 16 1 1 2 1 3 1DN 20 PN 16 1 2 2 2 3 2 0 0DN 25 PN 16 1 3 2 3 3 3DN 32 PN 16 1 4 2 4 3 4 DN 40 PN 16 1 5 2 5 3 5DN 50 PN 16 1 6 2 6 3 6 OtherDN 65 PN 16 1 7 2 7 3 7DN 80 PN 16 1 8 2 8 3 8 9 9DN 100 PN 16 1 9 2 9 3 9

Connection head

B (M24 x 1.5) 1 BUSH 6BUS 2 BUZH 7BUZ 3 8BBK 4 9

Sheath element (type/number of thermocouples/sheath material/diameter)

Thermocouple NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/NSheath material Alloy 600 2.4816 1.4541 1.4541 Alloy 600 2.4816Mat. no.

Sheath ø / mm

2 04 14 - - - - - -3 05 15 25 35 45 55 65 754.5 06 16 26 36 46 56 66 766 07 17 27 37 47 57 67 778 08 18 - - - - - -

SG*: 3.5 09 19 - - - - - -

* Special size/special material 00

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Custom designs: 1 2 - 9 9 1 2 x x x x -

Consecutive no. Installation length / Neck pipe length in mm

12 - THD // Welding-in thermocouples with a measuring insert and D-sleeves

Thermocouples, metal + sheath 1 2 - -

Installation length / Neck pipe length in mm

Page 26: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

13-TFL

13 - TFL // Thermocouples with blank flanges welded on

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 27: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

13 - TFL // Thermocouples with blank flanges welded on

Thermocouples with a blank flange welded on are used formeasuring temperatures in gaseous and in liquid or plasticmedia such as air, steam, water or oil.

A blank flange welded onto the thermocouple protection tubeensures that sensors of this kind can be securely fastened tothe walls of pressure and vacuum equipment, for example inpower plants and in chemical plants. The protection fittings atthe place of installation can remain in place even if the measuringinsert or the thermocouple needs to be replaced now and then.This ensures that operation does not need to be interrupted.

Most suitable areas of application:

Containers and pipings

Apparatus and machines

Laboratories

Test ranges

Process technology

Energy production and heat distribution

Food and beverages production

Machine and plant construction

The thermoelectric voltages and limiting deviations of ourthermocouples and sheath measuring inserts comply withParts 1 and 2 of the DIN EN 60584 norm; thermocouples andsheath measuring inserts of Type L comply with the DIN 43710norm.

The examples of products available for ordering shownin this catalogue are a selection of appliances frequentlyused in practice. The numerical code indicated on theback of the individual components can be used to drawup the respective order number of a standard thermal sensor,although not all of the possible combinations of numbersand materials are useful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components requiretechnical clarification. Please contact us if any specificproblems concerning material and assembly occur duringuse. The many years of experience we have gained shouldenable us to find the best possible solution for your specificproblem.

1 x NiCr-Ni/K straight flange thermocouplewith a DN 25 PN 16 blank flange, Type C

Order sample:

Product group: 13-TFLGünther Art. No.: 13-62333425-0500/0130

Connection head: Type BUZ (M24 x 1.5)Neck pipe: ø 15 x 2 mm, material no. 1.4841Protection tube: ø 15 x 2 mm, material no. 1.4841Sensor tip: ø 10 x 1.5 x 40 mmProcess connection: DN 25 PN 16 blank flange, Style C 1.4571

Welded onto a thermowellSheath element: 1 x NiCr-Ni/K ø 6.0 mm,

sheath made of Alloy 600Temperature range: 0 - 800°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 13-TFL Page 1 of 2

Neck pipe length

Installation length

Page 28: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

13 - TFL // Thermocouples with blank flanges welded on

Order sample:

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

2 x NiCr-Ni/K flange thermocouple with a Type BUZH connection headand a blind flange

Product group: 13-TFLGünther Art. No.: 13-99130012-1200/0100

Connection head: Type BUZH (M24 x 1.5) with PG 13.5Neck tube: ø 15 x 3 mm, material no. 1.4571Measuring insert: 2 x NiCr-Ni/K ø 6.0 mm, sheath made of Alloy 600Installation length: 1200 mmNeck pipe length: 100 mmFastening: 2” 200 lbs ANSI blank flange, mat. no. 1.4571Sensor tip: Not tapered, round plate welded inMeasuring insert Installation length = 1200 + 100 mm + 35 mmlength: Explosion-proof designTemperature range: 0 - 800°CMeasuring transducer: Digital, set acc. to instructions

Output 4.. 20 mA, explosion-proof designLimiting deviation: Class 1 acc. to DIN EN 60584-2

1 x NiCr-Ni/K thermocouple with a Type A connection head,tapered test probe and welded on blank flange

Product group: 13-TFLGünther Art. No.: 13-11733332-1150/0150

Connection head: Type AProtection tube: ø 22 x 2 mm, material no. 1.4762Measuring insert: 1 x NiCr-Ni/K ø 6.0 mm,

installation length = 1335 mmInstallation length: 1150 mmNeck pipe length: 150 mmFastening: DN65 PN16 blank flange, mat. no. 1.0305Sensor tip: 18 x 15 / 15 x 10 / 12 x 50 mm

Mat. no. 1.4762, offsetTemperature range: 0 - 1200°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 13-TFL Page 2 of 2

Neck pipe length

Installation length

Neck pipe length

Installation length

Page 29: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

ø / mm

3 31 41 51 61 71 81 91 964.5 32 42 52 62 72 82 92 976 33 43 53 63 73 83 93 988 34 44 - - - -

Outer protection tube / dimension

Material numberø 1.0305 1.4571 1.4762 1.4841 Alloy 600 Kanthal Alloy C4

6 x 0,75 0 1 1 2 2 3 3 4 4 5 5 6 6 78 x 1 0 2 1 3 2 4 3 5 4 6 5 7 6 89 x 1 0 3 1 4 2 5 3 6 4 7 5 8 6 910 x 1,5 0 4 1 5 2 6 3 7 4 8 5 9 7 011 x 1 0 5 1 6 2 7 3 8 4 9 5 0 7 111 x 2 0 6 1 7 2 8 3 9 4 0 6 1 7 212 x 1,5 0 7 1 8 2 9 3 0 5 1 6 2 7 312 x 2,5 0 8 1 9 2 0 4 1 5 2 6 3 7 415 x 2 0 9 1 0 3 1 4 2 5 3 6 4 7 515 x 3 0 0 2 1 3 2 4 3 5 4 6 5 7 622 x 2 1 1 2 2 3 3 4 4 5 5 6 6 7 7

Design

Standard [protection tube tube not tapered] 0

Fast response [protection tube tapered]Thermowell point 15 mm ø 1Thermowell point 12 mm ø 2Thermowell point 9 mm ø 3Thermowell point 6 mm ø 4Thermowell point 10 mm ø 5Thermowell point 8 mm ø 6 Other 9

Thermocouple insulatedin ceramic material

NiCr-Ni/K 11 21Fe-CuNi/J 12 22Fe-CuNi/L 13 23NiCrSi-NiSi/N 14 24PtRh10-Pt/S 15 25PtRh13-Pt/R 16 26PtRh30-PtRh6/B 17 27

Sta

ndar

d

Dou

ble

Sheathed measuring insert

NiCr-Ni Fe-CuNi Fe-CuNiType KI Type LV Type JV

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Blank flange in acc. St37-2 1.4571 C22.8 Alloy C4with DIN 2527

DN 10 PN 16 1 0 2 0 3 0 40 NoneDN 15 PN 16 1 1 2 1 3 1 41DN 20 PN 16 1 2 2 2 3 2 42 0 0DN 25 PN 16 1 3 2 3 3 3 43DN 32 PN 16 1 4 2 4 3 4 44DN 40 PN 16 1 5 2 5 3 5 45DN 50 PN 16 1 6 2 6 3 6 46 OtherDN 65 PN 16 1 7 2 7 3 7 47DN 80 PN 16 1 8 2 8 3 8 48 9 9DN 100 PN 16 1 9 2 9 3 9 49

Connection head

A 1 BUZ (M24 x 1.5) 62 BUSH (M24 x 1.5) 73 BUZH (M24 x 1.5) 8

B (M24 x 1.5) 4 DL / MA (M10 x 1) 9BUS (M24 x 1.5) 5 0

Custom designs: 1 3 - 9 9 1 3 x x x x -

Consecutive no. Installation length / Neck tube length in mm

13 - TFL // Thermocouples with blank flanges welded on

Thermocouples with blank flanges 1 3 - -

Installation length / Neck tube length in mm

Nicrosil-NisilType NI

Sta

ndar

d

Dou

ble

Other99

Page 30: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

14 - TES // Screw-in thermocouples

14-TES

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 31: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Screw-in thermocouples are used for standard temperaturemeasurements in the low-pressure range for gaseous, liquid andplastic media, depending on the quality of the thermowell andthe surrounding media, up to a temperature of 1200°C.

A screwed socket welded onto the thermowell ensures that thesensor of this assembly is securely connected to the processconnection.

The protection fittings are generally made of seamlessly extrudedstainless steel tubing with a welded in bottom base ronde.

Our screw-in thermocouples can be fitted with an additionalceramic inner tube if required, since this will markedly enhancethe permanent stability and the electrical insulation of the sensingthermocouples in many types of applications.

We recommend using sensors with a tapered thermowell pointif changes in temperature need to be recorded very quickly.

The thermoelectric voltages and limiting deviations of our thermo-couples and sheath measuring inserts comply with Parts 1and 2 of the DIN EN 60584 norm; thermocouples and sheathmeasuring inserts of Type L comply with the DIN 43710 norm.

The examples of products available for ordering shown inthis catalogue are a selection of appliances frequently usedin practice. The numerical code indicated on the back ofthe individual components can be used to draw up therespective order number of a standard thermal sensor,although not all of the possible combinations of numbersand materials are useful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components requiretechnical clarification. Please contact us if any specificproblems concerning material and assembly occur duringuse. The many years of experience we have gained shouldenable us to find the best possible solution for your specificproblem.

Günther GmbH · Temperaturmesstechnik

14 - TES // Screw-in thermocouples

Order sample:

1 x Fe-CuNi/L screw-in thermocouple witha G 1/2 A screw-in thread and a neck pipe

Product group: 14-TESGünther Art. No.: 14-14162701-0400/0140

Connection head: Type B (M24 x 1.5)Protection tube: ø 11 x 1 mm, material no. 1.4571Measuring insert: 1 x Fe-CuNi/L ø 6.0 mm,

installation length = 575 mmInstallation length: 400 mmNeck pipe length: 140 mmFastening: Screw-in-thread, mat. no. 1.4571 G 1/2 ASensor tip: Not tapered, closedTemperature range: 0 - 400°CLimiting deviation: 1/2 DIN 43710

Edition english 002 Product group 14-TES Page 1 of 2

Neck pipe length

Installation length

Insert length

Page 32: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

14 - TES // Screw-in thermocouples

Order sample:

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Product group: 14-TESGünther Art. No.: 14-11990500-0140

Connection head: Type B (M24 x 1.5)Protection tube: NoneMeasuring insert: 1 x NiCr-Ni/K ø 3.0 mm, resilient installation

Measuring point insulated, freely protrudingfrom the sleeve

Installation length: 140 mmFastening: Screw-in-thread, mat. no. 1.4571 G 1/2 ATemperature range: 0 - 1000°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

1 x NiCr-Ni/K screw-in thermocouple witha G 1/2 A screw-in thread, no protection tube

2 x NiCr-Ni/K screw-in thermocouple with a Type BUZHconnection head and a M27 x 1.5 screw-in thread

Product group: 14-TESGünther Art. No.: 14-99140071-1000/0100

Connection head: Type BUZH (M24 x 1.5) with PG 13.5Neck pipe: ø 15 x 3 mm, material no. 1.4571Measuring insert: 2 x NiCr-Ni/K ø 6.0 mm, sheath made

of Alloy 600Installation length: 1000 mmNeck pipe length: 100 mmFastening: M27 x 2 screwed socket made

of stainless steelSensor tip: Not taperedTemperature range: 0 - 800°CMeasuring transducer: Digital, set acc. to instructions

Output 4 - 20 mALimiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 14-TES Page 2 of 2

Installation length

Installation length

Neck pipe length

Page 33: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Design

Straight [protection tube not tapered] 0

Fast response [protection tube tapered]Tube point 15 mm ø 1Tube point 12 mm ø 2Tube point 9 mm ø 3Tube point 6 mm ø 4Tube point Other 9

Connection head

B (M24 x 1.5) 1 BUSH 6BUS 2 BUZH 7BUZ 3 NA 8BBK 4 DL / MA (M10x1) 9

5 Other 0

14 - TES // Screw-in thermocouples

1 4 - -

Installation length / Neck pipe length in mm

Custom designs: 1 4 - 9 9 1 4 x x x x -

Consecutive no. Installation length / Neck pipe length in mm

Screw-in-thread plug

Screwed plug, combined, M24 x 1.5 / G 1/2 A 1Screwed plug, combined, M10 x 1 / G 1/2 A 2Screwed plug G 1 A 3Screwed plug G 1/2 A 4Screwed plug M18x1.5 5Screwed plug G 3/4 A 6Screwed plug M20x1.5 7Other 0

Outer protection tube Material / dimensions No thermowell 99

ø No.1.0305 No.1.4571 No.1.4762 No.14841 No.2.4816 Kanthal

6 x 0.75 0 1 1 2 2 3 3 4 4 5 5 68 x 1 0 2 1 3 2 4 3 5 4 6 5 79 x 1 0 3 1 4 2 5 3 6 4 7 5 810 x 1.5 0 4 1 5 2 6 3 7 4 8 5 911 x 1 0 5 1 6 2 7 3 8 4 9 5 011 x 2 0 6 1 7 2 8 3 9 4 0 6 112 x 1.5 0 7 1 8 2 9 3 0 5 1 6 212 x 2.5 0 8 1 9 2 0 4 1 5 2 6 315 x 2 0 9 1 0 3 1 4 2 5 3 6 415 x 3 0 0 2 1 3 2 4 3 5 4 6 522 x 2 1 1 2 2 3 3 4 4 5 5 6 6

Type/number of thermocouples / sheath material / diameter

NiCr-Ni /K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil / NAlloy 600 2.4816 1.4541 1.4541 Alloy 600 2.4816

mm

Sheath 1,5 03 13 23 33 43 53 63 73measuring 2 04 14 - - - - - -insert 3 05 15 25 35 45 55 65 75

4,5 06 16 26 36 46 56 66 766 07 17 27 37 47 57 67 77

Thermocouple 1,0 08 18 28 38 48 58 68 782,0 09 19 29 39 49 59 69 793,0 00 10 20 30 40 50 60 70

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Neck pipe No 0 Yes 1

Page 34: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

15 -TKM // Thermocouples with a ceramic protection tube and a built-in sheath measurement insert

15-TKM

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 35: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

15 -TKM // Thermocouples with a ceramic protection tube and a built-in sheath measurement insert

Order sample:The number 15 product group comprises ready-to-install largeand small straight thermocouples with ceramic protection tubesand built-in sheath measurement inserts. They are used for technicaltemperature measurements for temperatures ranging from 200°Cto 1200°C at pressures of max. one bar.

Günther GmbH supplies any kind of standard straight thermocoupleas well as special custom-made models.

The main difference between thermocouples with thermocouplesinsulated in ceramic material (product group 00-TMT) andthermocouples with sheath measurement inserts is that in the caseof the latter the thermoelectric wires (internal conductors) areadditionally protected by a metal sheath – usually made of Alloy 600.

Unlike thermocouples, sheath measurement inserts are easy toreplace.

Properties of the most widely-used types of ceramic materials forthermowells and inner tubes in accordance with DIN 40685:

C 799 aluminium oxideGastight, highly fire-resistant, pure aluminium oxide > 99.7%, max.temp. of 1800°C

C 610 gastight ceramicGastight, high aluminium oxide content > 60%,max temp. of 1450°C

C 530 porous ceramic materialFine porosity, not gasproof, resistant to temperature changeHigh aluminium oxide content, max. temp. of 1500°C

The examples of products available for ordering shown inthis catalogue are a selection of appliances frequently usedin practice. The numerical code indicated on the back of theindividual components can be used to draw up the respectiveorder number of a standard thermal sensor, although not allof the possible combinations of numbers and materials areuseful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components require technicalclarification. Please contact us if any specific problemsconcerning material and assembly occur during use. The manyyears of experience we have gained should enable us to findthe best possible solution for your specific problem.

1 x NiCr-Ni/K thermal element with a Type A connectionhead and a stop flange, C 610 ceramic protection tube

Product group: 15-TKMGünther Art. No.: 15-62211731-1000

Connection head: Type AHolding tube: ø 32 x 2 x 200 mm, material no. 1.0305Protection tube: ø 24 x 19 mm, C610Inner tube: ø 15 x 11 mm, C610Measurement insert: 1 x NiCr-Ni/K ø 6.0 mm

with a ø 6.5 mm boreholeNominal length: 1000 mmFastening: DIN 43734 stop flange

Temperature range: 0 - 1100°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 15-TKM Page 1 of 2

Nominal length

Page 36: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

15 -TKM // Thermocouples with a ceramic protection tube and a built-in sheath measurement insert

More order samples:

1 x Fe-CuNi/J thermal element with a Type B connection head,a ceramic protection tube and a gasproof mounting thread

2 x NiCr-Ni/K thermal element with a Type AUZHconnection head and a C 530 protection tube

Product group: 15-TKMGünther Art. No.: 15-23106592-0600

Connection head: Type BHolding tube: ø 15 x 2 x 200 mm, material no. 1.0305Protection tube: ø 10 x 6 mm, C799, gasproofMeasurement insert: 1 x Fe-CuNi/J ø 3.0 mm, Inconel sheathNominal length: 600 mmFastening: Gastight mounting thread made of steel

for ø 15 mm, G 3/4 A

Temperature range: 0 - 800°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Product group: 15-TKMGünther Art. No.: 15-82214860-2000

Connection head: Type AUZHHolding tube: ø 32 x 2 x 200 mm, material no. 1.0305Protection tube: ø 26 x 18 mm, C530Inner tube: ø 15 x 11 mm, C610Measurement insert: 2 x NiCr-Ni/K ø 8.0 mm, testableNominal length: 2000 mmFastening: None

Temperature range: 0 - 1200°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2Feature: Measuring transducer fitted in the head,

4 - 20 mA, equivalent to 0-1200°C

Günther GmbH will calibrate your thermocouple in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Plug-in connections, connections, screw joints, compensation cables and accessories can befound in the catalogue under 99-EZT.

Edition english 002 Product group 15-TKM Page 2 of 2

Nominal length

Nominal length

Page 37: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Connection head A 1 B 6AUS 2 BUS 7AUZ 3 BUZ 8AUZH 4 BUZH 9AUSH 5 BBK 0

Fastening None 0 Mounting thread 2Stop flange 1 Flange/counter flange 3

Custom designs: 0 0 - 9 9 1 5 x x x x -

Consecutive no. Nominal length / mm

15 -TKM // Thermocouples with a ceramic protection tube and a built-in sheath measurement insert

Ceramic protection tube + sheath 1 5 - -

Nominal length / mmProtection tube 10 x 7 mm C610 1(dimensions / 10 x 6 mm C799 2material) 15 x 11 mm C610 3

15 x 10 mm C799 416 x 12 mm C610 524 x 19 mm C610 624 x 18 mm C799 726 x 18 mm C530 816 x 12 mm C799 9

Inner tube None 0C530 Porous ceramic material 1C610 Gastight ceramic 2C799 Aluminium oxide 3

Holding tube(visible length) 1.0305 1.4571 1.4762 1.4841

15x 2 50 mm 05 75 - -15 x 2 60 mm 06 76 26 3615 x 2 80 mm 07 77 27 3715 x 2 100 mm 08 78 28 3815 x 2 150 mm 09 79 29 3915 x 2 200 mm 10 80 30 4022 x 2 100 mm 11 81 31 4122 x 2 150 mm 12 82 32 4222 x 2 200 mm 13 83 33 4322 x 2 250 mm 14 84 34 4422 x 2 300 mm 15 85 35 4528.3 x 1.5 80 mm 16 - - -28.3 x 1.5 180 mm 17 - - -32 x 2 50 mm 18 88 - 4832 x 2 100 mm 19 89 - 4932 x 2 150 mm 20 90 - 7032 x 2 200 mm 21 91 - 7132 x 2 250 mm 22 92 - 72Alloy 600 (mat. no. 2.4816) Kanthal22 x 2 200 mm 61 15 x 1,3 100 mm 5122 x 2 300 mm 62 15 x 1,3 150 mm 5222 x 2 400 mm 63 15 x 1,3 200 mm 5322 x 2 500 mm 6430 x 2,5 230 mm 65 Individual 0030 x 2,5 400 mm 66 No holding tube 99

Sheath element (type/number of thermocouples/sheath material/diameter/verifiability)

NiCr-Ni /K Alloy 600 2.4816 Fe-CuNi/L 1.4541 Fe-CuNi/J 1.4541

ø / mm1.5 25 26 27 28 - 29 30 31 32 33 34 35 362 37 38 39 40 - 41 42 43 44 45 46 47 483 49 50 51 52 90 53 54 55 56 57 58 59 604.5 61 62 63 64 91 65 66 67 68 69 70 71 726 73 74 75 76 92 77 78 79 80 81 82 83 848 85 86 87 88 93 - - - - - - - -

Sta

ndar

dte

stab

le

Do

uble

test

able

Sta

ndar

d

Do

uble

Trip

le

Sta

ndar

dte

stab

le

Do

uble

test

able

Sta

ndar

d

Do

uble

Sta

ndar

dte

stab

le

Do

uble

test

able

Sta

ndar

d

Do

uble

Sta

ndar

dte

stab

le

Do

uble

test

able

Sta

ndar

d

Do

uble

10 11 12 1314 15 16 1718 19 20 2122 23 24 9495 96 97 98 - - - -

Nicrosil-Nisil/N 2.4816

Page 38: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

18-TKL

18 - TKL // Micro-thermocouples and laboratory thermocouples

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 39: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

18 - TKL // Micro-thermocouples and laboratory thermocouples

Order sample:The 18-TKL product group comprises ready-to-install straightmicro-thermocouples and laboratory thermocouples with ceramicprotection tubes and built-in thermocouples.These sensors are mainly used for technical temperaturemeasurements for temperatures ranging from 200°C to1800°C at pressures of max. one bar.

The highest permissible operation temperature of a selectedthermocouple material or of the protection tube material determinesthe maximum operation temperature of the thermocouple.

Properties of the most widely-used types of ceramic materials forprotection tubes and inner tubes in accordance with DIN 40685:

C799 aluminium oxideGastight, highly fire-resistant, 99.7% pure,maximum operation temperature of 1800°C

C610 gastight ceramicGastight, high aluminium oxide content > 60%,maximum operation temperature of 1450°C

C530 porous ceramic materialNot gastight, medium-fine structure, resistant to temperaturechange, high aluminium oxide content, maximum operationtemperature of 1500°C

Micro-thermocouples have the following advantages:The small size enables temperatures to be measured in placeswhich are difficult to access.Short response times as a result of a compact design

Limiting deviations of the micro-thermocouples supplied byGünther GmbH comply with the DIN EN 60584 norm.

The examples of products available for ordering shown in thiscatalogue are a selection of appliances frequently used inpractice. The numerical code indicated on the back of theindividual components can be used to draw up the respectiveorder number of a standard thermal sensor, although not allof the possible combinations of numbers and materials areuseful or technically viable.

Special numbers are developed by us for special thermalsensors whose construction and components require technicalclarification. Please contact us if any specific problemsconcerning material and assembly occur during use. Themany years of experience we have gained should enable usto find the best possible solution for your specific problem.

1 x PtRh10-Pt/S thermocouple with a Type Lconnection head and a bracket clamp,protection tube made of C799 ceramic material

Günther Art. No.: 18-91499210-0270

Connection head: Type L with an 8-mm bracket clamp

Holding tube: NoneProtection tube: ø 8 x 5 mm, C799Insulation rod: ø 4.0 mm, C799Thermocouple: 1 x PtRh10-Pt/S ø 0.5 mmNominal length: 270 mmFastening: NoneTemperature range: 0 - 1600°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 18-TKL Page 1 of 3

Nominal length

Page 40: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

18 - TKL // Micro-thermocouples and laboratory thermocouples

More order samples:

2 x NiCr-Ni/K thermocouple with a Type DL connection head 1 x PtRh10-Pt/S micro-thermocouple with an angle bracketand ceramic insulating screw joint

Günther Art. No.: 18-61227421-0165

Connection head: Type DL with an M10 x 1 connection threadHolding tube: ø 10 x 1 mm, made of brassProtection tube: ø 7.5 x 4.5 mm, C610Insulation rod: ø 3.5 mm, C610Thermocouple: 2 x NiCr-Ni/K ø 0.5 mmNominal length: 165 mm

Fastening: 50 mm attachment flange made ofstainless steel

Temperature range: 0 - 800°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Günther Art. No.: 18-99180291-0170

Connection: 20 x 20 mm insulating screw joint,connections insulated with siliconehosing

Clamp: ø 9 mmProtection tube: ø 10 x 7 mm, C799, with a cemented

stop ring, ø 15 x 5 mmInsulation rod: ø 5.0 mm, C799Thermocouple: 1 x PtRh10-Pt/S ø 0.3 mmNominal length: 170 mm (up to the stop ring)

Fastening: Angle bracket

Temperature range: 0 - 1300°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in thecatalogue under 99-EZT.

Edition english 002 Product group 18-TKL Page 2 of 3

Nominal length

Nominal length

Page 41: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Günther Art. No.: 18-99180125-0460

Connection: Standard high-temperature plug

Protection tube: ø 8 x 5 mm, C799Holding tube: ø 12 x 2 x 80 mm, made of brassInsulation rod: ø 5.5 mm, C799

Thermocouple: 1 x WRe5-WRe26/C ø 0.5 mmNominal length: 460 mm

Fastening: None

Temperature range: 0 - 1700°C

Feature: Thermowell filled with argon,gas-tight

18 - TKL // Micro-thermocouples and laboratory thermocouples

More order samples:

1xPtRh10-Pt/S laboratory thermocouple with a Type S baseand connection clip

1 x WRe5-WRe26/C small thermocouple with a ceramicprotection tube and a standard plug connected

Günther Art. No.: 18-23599210-0160

Connection: Base, Type S, dual-pole

Protection tube: ø 6 x 4 mm, C799Holding tube: ø 8 x 0.5 x 30 mm, material no. 1.4301Insulation rod: ø 3.0 mm, C799Thermocouple: 1 x PtRh10-Pt/S ø 0.3 mmNominal length: 160 mm

Fastening: Connection clip, 55 x 20 mm

Temperature range: 0 - 1400°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in the catalogueunder 99-EZT.

Edition english 002 Product group 18-TKL Page 3 of 3

Nominal length

Nominal length

Page 42: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

ThermocoupleType R PtRh13-Pt 1Type S PtRh10-Pt 2Type B PtRh30-PtRh6 3Type K NiCr-Ni 4Type J Fe-CuNi 5Type L Fe-CuNi 6Type C WRe5-WRe26 7Type N Nicrosil-Nisil 8Type D WRe3-WRe25 9

Fastening None 0Stop flange 1Mounting thread 2Flange/counter flange 3

Contact terminations

Head Type B 12.2 mm 11Head Type DL with an M10 x 1 thread 12Head Type L with a bracket clamp 7 mm 13Head Type L with a bracket clamp 8 mm 14Connection socket Type S with a bracket clamp 7 mm 15Connection socket Type S with a bracket clamp 8 mm 16

The following contact terminations are fitted withholding tubes which have been permanently welded on:

Head Type L with tube 1.4571, 10 x 1 x 20 mm 31and a Type S connection socket

Head Type L with tube 1.4571, 9 x 1 x 20 mm 32and a Type S connection socket

Type S connection socket with a tube 1.4571, 10 x 0.5 x 24 mm 33Type S connection socket with a tube 1.4571 34Connection clip, 55 x 20mm, with a tube 1.4571, 8 x 0.5 x 30 mm 35

and a Type S connection socketConnection clip, 55 x 20mm, with a tube 1.4571, 10 x 0.5 x 24 mm 36

and a Type S connection socketFlanged plate, 60 x 60 mm with a holding tube 1.4571, 12 x 2 x 25 mm 37

and a Type S connection socket

Holding tubesSt. 35.8 Brass 1.4571 Alloy 600

6 x 0.5 1 0 2 0 3 0 4 0 None7 x 1.0 1 1 2 1 3 1 4 18 x 0.5 1 2 2 2 3 2 4 2 9 98 x 1.0 1 3 2 3 3 3 4 39 x 0.5 1 4 2 4 3 4 4 49 x 1.0 1 5 2 5 3 5 4 5

10 x 0.5 1 6 2 6 3 6 4 6 Other10 x 1.0 1 7 2 7 3 7 4 711 x 1.0 1 8 2 8 3 8 4 8 0 012 x 0.75 1 9 2 9 3 9 4 912 x 1.0 5 0 6 0 7 0 8 0

Protection tube 6 x 4 mm C610 1(dimensions / 6 x 4 mm C799 2material) 7 x 4 mm C799 3

7 x 4.5 mm C610 47.5 x 5.5 mm C610 5

8 x 5 mm C610 610 x 7 mm C610 710 x 6 mm C799 8 8 x 5 mm C799 9

Custom designs: 1 8 - 9 9 1 8 x x x x -

Consecutive no. Nominal length / mm

18 - TKL // Micro-thermocouples and laboratory thermocouples

Ceramic protection tube + thermocouple 1 8 - -

Nominal length / mm

ThermocoupleStandard 1Double 3Triple 5

Page 43: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

20 - TOM // Sheath thermocouples without protection tube

20-TOM

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 44: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

20 - TOM // Sheath thermocouples without protection tube

Order sample:Flexible sheath thermocouples are used in virtually all areas ofindustry. They are primarily used for measuring temperatures inpipe systems, containers, machines, furnaces, laboratories and allkinds of industrial equipment.Sheath thermometers can be used in a variety of media, dependingon the choice of dimensions and of the sheathing material.

Sheath thermocouples mainly comprise thermal wires (internalconductors) and a metal sheath, usually made of Alloy 600. Twointernal conductors welded together form a thermocouple whichis firmly pressed into insulating ceramic powder (generallymagnesium oxide). A sheath thermocouple can hold up to threethermocouples.

The outer diameter of the sheath is between 0.5 mm and 8 mm(optional sizes on request).

Sheath thermocouples have numerous advantages:

The small size and a high degree of flexibility enable temperaturesto be measured in places which are difficult to access.

Response times are short as a result of a compact design.

The outer sheath protects the thermal wires against oxidation,corrosion and chemical pollution.

Sheath thermocouples are able to resist many types of mechanical stress.

Thermoelectric voltages and limiting deviations of the sheaththermocouples supplied by Günther GmbH comply either withthe DIN 43710 norm or with the DIN EN 60584 norm (DIN 43710has actually been withdrawn, but is still available).

The examples of products available for ordering shown inthis catalogue are a selection of appliances frequently usedin practice. The numerical code indicated on the back of theindividual components can be used to draw up the respectiveorder number of a standard thermal sensor, although not allof the possible combinations of numbers and materials areuseful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components require technicalclarification. Please contact us if any specific problemsconcerning material and assembly occur during use. The manyyears of experience we have gained should enable us to findthe best possible solution for your specific problem.

2 x NiCr-Ni/K sheath thermocouple with a connectedcompensation cable and a cable transition sleeve

Product group: 20-TOMGünther Art. No.: 20-40151743-0500

Connection: Cable transition sleeve madeof stainless steel

Protective system: IP 65Thermocouple: 2 x NiCr-Ni/K ø 6.0 mmSheath: Alloy 600, mat. no. 2.4816Fastening: Movable screw joint made

of stainless steel G 1/2 A,mat. no. 1.4571

Nominal length: 500 mmTemperature range: 0 - 1100°CLimiting deviation: Class 1 acc. to DIN EN 60584-2Compensation cable: 2 x 0.22 mm2 conductors, individually

and jointly silicon-insulated

Edition english 002 Product group 20-TOM Page 1 of 3

Nominal length

Page 45: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

20 - TOM // Sheath thermocouples without protection tube

More order samples:

1 x Nicrosil-Nisil/N sheath thermocouple fittedwith a standard plug

2 x Fe-CuNi/L sheath thermocouple witha Style DL connection head

Product group: 20-TOMGünther Art. No.: 20-30308643-1355

Connection: Standard plug made of plastic,thermoelectrically disconnected

Thermocouple: 1 x Nicrosil-Nisil/N ø 4.5 mmSheath: Inconel, mat. no. 2.4816Fastening: Movable screw joint made of

stainless steel G 1/4 A,mat. no. 1.4571 with a Teflon clamping ring

Nominal length: 1355 mmTemperature range: 0 - 1200°C

Limiting deviation: Class 1 acc. to DIN EN 60584-2

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in the catalogueunder 99-EZT.

Sheath thermocouples are ideal test elements thanks to their compact structure.

Product group: 20-TOMGünther Art. No.: 20-20403699-0250

Connection: Style DL connection head witha M10 x 1 connection thread

Thermocouple: 2 x Fe-CuNi/L ø 4.5 mmSheath: Stainless steel, mat. no. 1.4541Fastening: None

Nominal length: 250 mmTemperature range: 0 - 800°CLimiting deviation: 1/2 DIN 43710Compensation cable: None

Optional: e.g. with a connected compensation cable2 x 0.22 mm2 PVC-PVC

Edition english 002 Product group 20-TOM Page 2 of 3

Nominal length Nominal length

Page 46: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

20 - TOM // Sheath thermocouples without protection tube

More order samples:

2 x Nicrosil-Nisil/N sheath thermocouple with a Type BUZconnection head and a combined screw socket

2 x Fe-CuNi/J sheath thermocouple with a Type Bconnection head and a counter-screw

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in the catalogueunder 99-EZT.

Sheath thermocouples are ideal test elements thanks to their compact structure.

Product group: 20-TOMGünther Art. No.: 20-20259482-0315

Connection: Type BUZ connection head witha M24 x 1.5 connection thread

Thermocouple: 2xNicrosil-Nisil/N ø 2.0 mmSheath: Stainless steel, mat. no. 1.4541Fastening: Combined screw socket

made of stainless steel 1.4571M24 x 1.5 / G 1/2 A

Installation length: 315 mmTemperature range: 0 - 1100°CLimiting deviation: Class 1 acc. to DIN EN 60584-2Feature: Sheath firmly welded in the screw socket;

thermocouple is welded to the sheath bottom

Product group: 20-TOMGünther Art. No.: 20-20104799-0500

Connection: Type B connection head witha M24 x 1.5 connection thread

Thermocouple: 2 x Fe-CuNi/J ø 6.0 mmSheath: Stainless steel, mat. no. 1.4541Fastening: None

Nominal length: 500 mmTemperature range: 0 - 800°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Compensation cable: None

Edition english 002 Product group 20-TOM Page 3 of 3

Installation length

Nominal length

Page 47: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Fastening:Attachment screw joint: Material Steel / Stainless steel

(Tapered ring unit, mat. no. 1.4541)M 8 x 1 for sheath ø 1.0-3.0 mm 11 21G 1/8 A for sheath ø 1.0-3.0 mm 12 22G 1/4 A for sheath ø 4.5-8.0 mm 13 23G 1/2 A for sheath ø 4.5-8.0 mm 14 24

(Tapered ring unit St. 35.8) Screw jointM 8 x 1 for sheath ø 1,0-3,0 mm 51 31 G 1/4 A 80G 1/8 A for sheath ø 1,0-3,0 mm 52 32 G 3/8 A 81G 1/4 A for sheath ø 4,5-8,0 mm 53 33 G 1/2 A 82G 1/2 A for sheath ø 4,5-8,0 mm 54 34 G 1 A 83

M 20 x 1.5 84M 18 x 1.5 85

(Teflon thrust collar) M 14 x 1.5 86M 8 x 1 for sheath ø 1.0-3.0 mm 61 41G 1/8 A for sheath ø 1.0-3.0 mm 62 42 No fastening 99G 1/4 A for sheath ø 4.5-8.0 mm 63 43G 1/2 A for sheath ø 4.5-8.0 mm 64 44 Other 88

Connection headwith a connection thread with a connection diameter of 15.3 mmB (M24 x 1.5) 20 10 B 25 10BUS (M24 x 1.5) 20 15 BUS 25 15BUSH (M24 x 1.5) 20 20 BUSH 25 20BUZ (M24 x 1.5) 20 25 BUZ 25 25BUZH (M24 x 1.5) 20 30 BUZH 25 30BBK (M24 x 1.5) 20 35 BBK 25 35DL (MA) (M10 x1) 20 40 DL (MA) 25 40

Joining elementsPlug CouplerLemo Size 0 30 10 Lemo Size 0 35 10Lemo Size 1 30 15 Lemo Size 1 35 15Lemo Size 2 30 20 Lemo Size 2 35 20Lemo Size 3 30 25 Lemo Size 3 35 25Standard 30 30 Standard 35 30Miniature 30 35 Miniature 35 35High-temp standard 30 40 High-temp standard 35 40 High-temp miniature 30 45 High-temp miniature 35 45Ceramic standard 30 50 Ceramic standard 35 50Ceramic miniature 30 55 Ceramic miniature 35 55

Cable transition sleeve + compensation cable 4X XX(XXX = length of the compensation cable in XX.X m)

Custom designs: 2 0 - 9 9 2 0 x x x x -

Consecutive no. Nominal length / mm

20 - TOM // Sheath thermocouples without protection tube

Sheath thermocouple 2 0 - -

Nominal length / mm

Sheath element (type/number of thermocouples/sheath material/diameter)

Thermocouple NiCr-Ni /K Fe-CuNi/L Fe-CuNi/J PtRh-Pt/S Nicrosil-Nisil/NSheath material Alloy 600 2.4816 1.4541/2.4816 1.4541/2.4816 Alloy 600 2.4816 Alloy 600 2.4816

Sheath ø / mm

0.5 01 - - - - - - - - - -1 02 - - 22 - 42 - 62 - 82 -1.5 03 13 - 23 33 43 53 63 73 83 932 04 14 - 24 34 44 54 64 74 84 943 05 15 69 25 35 45 55 65 75 85 954.5 06 16 79 26 36 46 56 66 76 86 966 07 17 89 27 37 47 57 67 77 87 978 08 18 99 - - - - - - - -3.2 09 19 - - - - - - - - -

Special size / Special material 00

Sta

ndar

d

Dou

ble

Trip

le

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Page 48: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

30 - WTE // Angle thermocouples with a bolted central angle

30-WTE35-WGG

35 - WGG // Angle thermocouples curved out of one segmentAngle thermocouples with welded together dip and carrier tube

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 49: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

30 - WTE // Angle thermocouples with a bolted central angle35 - WGG // Angle thermocouples curved out of one segment

Angle thermocouples with welded together dip and carrier tube

Order sample:

The list contains ready-to-install angle thermocouples. Theseelements are divided into two product groups at Günther GmbH:a) 30-WTE angle thermocouples with a screwed tube bend b) 35-WGG angle thermocouples whose dip and carrier tubes are curvedfrom one piece or are welded together. Angle thermocouples areprimarily used for measuring and regulating temperatures in moltenmetals and in salt baths. The angular shape ensures that theconnection head is not located right above the bath level so thatit is not subjected to the high temperatures and aggressive steamspresent.

The materials for the thermocouple and the protection tube willneed to be selected with a view to the operating conditions prevailingin order to ensure that the service life of the appliances is adequate.

Recommended protection tube materialsfor tused salt

Tenifer up to 600°C Titan NTSodium nitrate, chlorideand annealing, temperingand quenching bathscontaining cyanide up to 1000°C Pure iron

1.4821 (SL25)up to 1300°C Pure iron

For molten metal

Aluminium Grey cast ironup to 700°C Graphite

MagnesiumAl/Mg alloy up to 700°C Pure ironLead up to 600°C Grey cast ironZinc Pure iron

up to 600°C SteelCopper up to 1200°C 1.4762

GraphiteBrass up to 900°C 1.4762

GraphiteInformation provided in this table is for information only and is without responsibility.

Thermoelectric voltages and limiting deviations of the anglethermocouples supplied by Günther GmbH comply either withthe DIN 43710 norm or with the DIN EN 60584 norm.

The examples of products available for ordering shown in thiscatalogue are a selection of appliances frequently used in practice.The numerical code indicated on the back of the individualcomponents can be used to draw up the respective order numberof a standard thermal sensor, although not all of the possiblecombinations of numbers and materials are useful or technicallyviable.Special numbers are developed by us for special thermal sensorswhose construction and components require technical clarification.Please contact us if any specific problems concerning materialand assembly occur during use. The many years of experiencewe have gained should enable us to find the best possible solutionfor your specific problem.

1 1/4”-1 x NiCr-Ni/K angle thermocouple witha Type A connection head, a pure iron dip tubewith a protection sleeve welded onto the tube

1 1/4”- 1 x Fe-CuNi/L angle thermocouple witha Type A connection head and titanium dip tube

Product group: 30-WTEGünther Art. No.: 30-51111203-0500x0500

Connection head: Type A IP 54Carrier tube: ø 22 x 2 mm, material no. 1.0305Dip tube: a protection sleeve made of

smoke tube welded onto thedip tube32 x 4 mm

Elbow: 1 1/4” with 2 screw nipplesThermocouple: 1 x NiCr-Ni/K ø 3.0 mmCarrier tube NL: 500 mmDip tube NL: 500 mmTemperature range: 0 - 1100°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Product group: 30-WTEGünther Art. No.: 30-51131713-0500x0500

Connection head: Type A IP 54Carrier tube ø 22 x 2 mm, material no. 1.0305Dip tube: ø 18 x 1.5 mm, made of titaniumElbow: 1 1/4” with 2 screw nipplesInner tube: ø 10 x 7 mm, C610Thermocouple: 1 x Fe-CuNi/L ø 1.5 mmCarrier tube NL: 500 mmDip tube NL: 500 mmTemperature range: 0 - 600°CLimiting deviation: 1/2 DIN 43710

Edition english 002 Product group 30-WTE, 35-WGG Page 1 of 4

Carrier tubenominal length

Dip

tub

eno

min

al le

ngth

Carrier tubenominal length

Dip

tub

eno

min

al le

ngth

Page 50: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

30 - WTE // Angle thermocouples with a bolted central angle35 - WGG // Angle thermocouples curved out of one segment

Angle thermocouples with welded together dip and carrier tube

More order samples:

1 1/4”- 1 x PtRh10-Pt/S angle thermocouple with a Type Aconnection head and SL25 dip tube

3/8” - 1 x NiCr-Ni/K angle thermocouple with a Type Bconnection head and a 1.4762 steel dip tube

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Product group: 30-WTEGünther Art. No.: 30-51151323-0500x0500

Connection head: Type A IP 54Carrier tube: ø 22 x 2 mm, material no. 1.0305Dip tube: ø 30 x 9 mm, made of SL25

Point tapered (ø 24 mm,l = 50 mm), tube drilled

Elbow: 1 1/4” with 2 screw nipplesInner tube: ø 8 x 5 mm, C799Thermocouple: 1 x PtRh10-Pt/S ø 0.5 mmCarrier tube NL: 500 mmDip tube NL: 500 mmTemperature range: 0 - 1300°CLimit deviation: Class 1 acc. to DIN EN 60584-2

Product group: 30-WTEGünther Art. No.: 30-16112302-0500x0500

Connection head: Type B IP 54Carrier tube: ø 15 x 2 mm, material no. 1.0305Dip tube: ø 15 x 2 mm, material no. 1.4762Inner tube: NoneElbow: Tube bend 3/8”Thermocouple: 1 x NiCr-Ni/K ø 1.38 mmCarrier tube NL: 500 mmDip tube NL: 500 mmTemperature range: 0 - 1100°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

1 1/4” - 2 x NiCr-Ni/K angle thermocouple with a Type Aconnection head and an dip tube made of grey cast iron

Product group: 30-WTEGünther Art. No.: 30-51211403-0500x0710

Connection head: Type A IP 54Carrier tube: ø 22 x 2 mm, material no. 1.0305Dip tube: ø 30 x 6 mm, made of gray

cast iron GG-22Elbow: 1 1/4” with 2 screw nipplesThermocouple: 2 x NiCr-Ni/K ø 1.38 mmCarrier tube NL: 500 mmDip tube NL: 710 mmTemperature range: 0 - 800°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 30-WTE, 35-WGG Page 2 of 4

Carrier tubenominal length

Dip

tub

eno

min

al le

ngth

Carrier tubenominal length

Dip

tub

eno

min

al le

ngth

Carrier tubenominal length

Dip

r tu

be

nom

inal

leng

th

Page 51: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

30 - WTE // Angle thermocouples with a bolted central angle35 - WGG // Angle thermocouples curved out of one segment

Angle thermocouples with welded together dip and carrier tube

More order samples:

1 1/4” - 1 x NiCr-Ni/K angle thermocouple with a Type Aconnection head, graphite dip tube

Product group: 30-WTEGünther Art. No.: 30-51111603-0500x0500

Connection head: Type A IP 54Carrier tube: ø 22 x 2 mm, material no. 1.0305Dip tube: Graphite thermowell

50 x 25 mm with inner tubemade of steel and R1/2”reducing nozzle 1 1/4”- 1/2”

Elbow: 1 1/4” with reducing nozzleInner tube: NoneThermocouple: 1 x NiCrNi/K ø 2.0 mmCarrier tube NL: 500 mmDip tube NL: 500 mmTemperature range: 0 - 1200°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

3/8” - 1 x Fe-CuNi/L angle thermocouple with a Style Bconnection head, dip tube made of 1.4841 and a sheathmeasurement insert

1 1/4” - 1 x NiCr-Ni/K angle thermocouple with a Type Aconnection head, no dip tube

Product group: 30-WTEGünther Art. No.: 30-51110003-0500x0500

Connecting head: Type A IP 54Carrier tube: ø 22 x 2 mm,

material no. 1.0305Dip tube: NoneElbow: 1 1/4” with reducing nozzleThermocouple: 1 x NiCr-Ni/K ø 3.0 mm

thermocouple 445 mmprotruding 1 1/4”-3/4” out of a reducing nozzle

Carrier tube NL: 500 mmDip tube NL: Suitable for 500 mmTemperature range: 0 -1200°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Product group: 30-WGGGünther Art. No.: 30-16512402-0500x0500

Connection head: Type B IP 54Carrier tube: ø 15 x 2 mm, material no. 1.0305Dip tube: ø 15 x 2 mm, material no. 1.4841Inner tube: NoneMeasurement insert: 1xFe-CuNi/L, ø 2.0 mm

Measuring point welded to the baseCarrier tube NL: 500 mmDip tube NL: 500 mmTemperature range: 0 - 1000°CLimiting deviation: 1/2 DIN 43710Elbow: Tube bend 3/8”

Edition english 002 Product group 30-WTE, 35-WGG Page 3 of 4

Carrier tubenominal length

Dip

tub

eno

min

al le

ngth

Carrier tubenominal length

Freely-protruding thermocouple tubes and reducing nozzleswhich may be required must be indicated for production!

Dip

tub

eno

min

al le

ngth

Carrier tubenominal length

Page 52: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

30 - WTE // Angle thermocouples with a bolted central angle35 - WGG // Angle thermocouples curved out of one segment

Angle thermocouples with welded together dip and carrier tube

More order samples:

1 x NiCr-Ni/K angle thermocouple with a Type A connection head,pure iron protection tube, curved at a right angle

Product group: 35-WGGGünther Art. No.: 35-81330033-0500x0710

Connection head: Type A IP 54Protection tube: ø 22 x 5 mm, made of pure iron,

curved at a right angleInner tube: NoneMeasurement insert: 1 x NiCr-Ni/K ø 6.0 mmSheath material: InconelCarrier tube NL: 500 mmDip tube NL: 710 mmTemperature range: 0 - 1000°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

2x Fe-CuNi/J angle thermocouple with a Type B connection head,dip and carrier tube material no. 1.4571, welded at a right angle

2 x Fe-CuNi/J angle thermocouple with a Type A connection head,1.4571 protection tube, curved at a right angle

Product group: 35-WGGGünther Art. No.: 35-81210022-0500x0500

Connection head: Type A IP 54Protection tube: ø 22 x 2 mm, material no. 1.4571,

curved at a right angleThermocouple: 2 x Fe-CuNi/J ø 3.0 mm,

ceramic insulation Carrier tube NL: 500 mmDip tube NL: 500 mmTemperature range: 0 - 800°CLimit deviation: Class 1 acc. to DIN EN 60584-2

Product group: 35-WGGGünther Art. No.: 35-1110022-0400x0300

Connection head: Type B IP 54Dip and carrier tube: ø 15 x 2 mm, material no. 1.4571,

welded at a right angleInner tube: NoneThermocouple: 2 x Fe-CuNi/J ø 2.0 mm,

ceramic insulationCarrier tube NL: 400 mmDip tube NL: 300 mmTemperature range: 0 - 800°CLimiting deviation: Class 1 acc. to DIN EN 60584-2

Edition english 002 Product group 30-WTE, 35-WGG Page 4 of 4

Dip

tub

eno

min

al le

ngth

Carrier tubenominal length

Dip

tub

eno

min

al le

ngth

Carrier tubenominal length

Dip

tub

eno

min

al le

ngth

Carrier tubenominal length

Surroundingweld seam

75

M 20 x 1.5

M 20 x 1.5

Page 53: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Nominal length Nominal lengthCarrier tube (mm) Dip tube (mm)

Inner tube

None 0C610 gastight ceramic 1C799 Aluminium oxide 2

Elbow:

Curved angle 3/4" 1Curved angle 3/8" 2Curved angle 1 1/4" 3Curved angle 1/2" 4

Dip tube (material / dimensions)

None, thermocouples freely protruding 0 0

Pure iron (techn. pure), ø = 22 x 5 mm, seamless 1 1Pure iron (techn. pure), ø = 22 x 5 mm, with a protection sleeve 1 2Steel SL 25 ø = 30 x 9 mm; point tapered (ø = 24) to 50 mm length 1 3Grey cast iron GG-22, ø = 30 x 6 mm 1 4Graphite ø = 40 x 11 mm 1 5Graphite ø = 50 x 25 mm 1 6Titanium ø = 18 x 1.5 mm pressed and welded 1 7Titanium ø = 18 x 1.0 mm, with a welded round base 1 8Glassed steel ø = 22 x 2 mm 1 9

Material Number Dimensions in mm15 x 2 17 x 2 22 x 2 22 x 2.5 22 x 4

Stainless steel 1.4541 - 3 1 4 1 - -Stainless steel 1.4571 2 2 3 2 4 2 5 2 6 2X10CrAl 24 1.4762 2 3 3 3 4 3 - -X15CrNiSi 25 20 1.4841 2 4 3 4 4 4 - -Alloy 600 2.4816 2 5 3 5 4 5 - -

Head A 1 B 6AUS 2 BUS 7AUZ 3 BUZ 8AUZH 4 BUZH 9AUSH 5 BBK 0

Custom designs: 3 0 - 9 9 3 0 x x x x - x

30 - WTE // Angle thermocouples with a bolted central angle

Metal protection tube + thermocouple 3 0 - - x

Nominal length Nominal lengthCarrier tube (mm) Dip tube (mm)

Carrier tube St 35.8 15 x 2 mm 1(material / St 35.8 17 x 2.5 mm 2dimensions) 1.4571 15 x 2 mm 3

1.4571 17 x 3 mm 4St 35.8 22 x 2 mm 51.4571 22 x 2 mm 6

Thermocouple withceramic insulation

NiCr-Ni/K 11 21Fe-CuNi/J 12 22Fe-CuNi/L 13 23Nicrosil-Nisil/N 14 24PtRh10-Pt/S 15 25PtRh13-Pt/R 16 26PtRh30-PtRh6/B 17 27

Sta

ndar

d

Dou

ble

Sheath measurement insert

NiCr-Ni Fe-CuNi Fe-CuNiType KI Type LV Type JV

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

ø / mm

3.0 31 41 51 61 71 81 91 944.5 32 42 52 62 72 82 92 956.0 33 43 53 63 73 83 93 968.0 34 44 - - - - - -

Sta

ndar

d

Dou

ble

Nicrosil-NisilType NI

Consecutive no.

Page 54: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Sheath measurement insert

NiCr-Ni Fe-CuNi Fe-CuNiType KI Type LV Type JV

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

Sta

ndar

d

Dou

ble

ø / mm

3.0 31 41 51 61 71 81 91 944.5 32 42 52 62 72 82 92 956.0 33 43 53 63 73 83 93 968.0 34 44 - - - - - -

Sta

ndar

d

Dou

ble

Nicrosil-NisilType NI

Welded thermowell

Dimensions in [mm] Material1.0305 1.4571 1.4762 1.4841 2.4816

12 x 1 11 xxxx 12 xxxx 13 xxxx 14 xxxx 15 xxxx12 x 1.5 21 xxxx 22 xxxx 23 xxxx 24 xxxx 25 xxxx15 x 2 31 xxxx 32 xxxx 33 xxxx 34 xxxx 35 xxxx15 x 3 41 xxxx 42 xxxx 43 xxxx 44 xxxx 45 xxxx16 x 2 51 xxxx 52 xxxx 53 xxxx 54 xxxx 55 xxxx22 x 2 61 xxxx 62 xxxx 63 xxxx 64 xxxx 65 xxxx

(xxxx = length of the compensation cable in mm)

35 - WGG // Angle thermocouples curved out of one segmentAngle thermocouples with welded together dip and carrier tube

Article number 3 5 - - x

Carrier tube Dip tubenominal length (mm) nominal length (mm)

Ceramic insulation

NiCr-Ni/K 11 21Fe-CuNi/J 12 22Fe-CuNi/L 13 23Nicrosil-Nisil/N 14 24

Sta

ndar

d

Dou

ble

Thermocouple (type / number)

Custom designs: 3 5 - 9 9 3 5 x x x x - x

Protection tube curved at a right angle, with a connection head

Protection tube 15 x 2 mm / mat. no.1.4571 / with connection head Type B 811 100Protection tube 15 x 2 mm / mat. no.1.0305 / with connection head Type B 811 200Protection tube 22 x 2 mm / mat. no.1.4571 / with connection head Type A 812 100Protection tube 22 x 2 mm / mat. no.1.0305 / with connection head Type A 812 200Protection tube 22 x 5 mm / pure iron / with connection head Type A 813 300

Protection tube welded at a right angle, with a connection headProtection tube 15 x 2 mm / mat. no.1.4571 / with connection head Type B 821 100Protection tube 15 x 2 mm / mat. no.1.0305 / with connection head Type B 821 200Protection tube 22 x 2 mm / mat. no.1.4571 / with connection head Type A 822 100Protection tube 22 x 2 mm / mat. no.1.0305 / with connection head Type A 822 200Protection tube 22 x 5 mm / pure iron / with connection head Type A 823 300

The last two digits are replaced with “xx” for models without a connection head

Carrier tube Dip tubenominal length (mm) nominal length (mm)

Consecutive no.

Page 55: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

50-WMS

50 - WMS // Straight resistance thermometers with a metal thermowelland a built-in measurement insert

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 56: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

50 - WMS // Straight resistance thermometers with a metal protection tubeand a built-in measuring insert

Order sample:The 50-WMS product group comprises ready-to-install large andsmall straight resistance thermometers with built-in measurementinsert. Sensors of this kind are installed for standard temperaturemeasurements in liquid and gaseous media. Refrigeration technology,air-conditioning systems, heating systems, furnaces, the manufactureof chemical equipment and the chemical industry are typical areasof application. Thermowells made of various materials protect themeasurement insert against chemical corrosion and againstmechanical damage. The choice of a suitable material for thethermowell will depend on prevailing conditions.The measurement insert is fitted with a 1x or 2x Pt 100 in accordancewith IEC 751 Class B two-wire circuit temperature sensor asa standard. Precision resistors with a tight tolerance and witha 500-ohm or 1000-ohm resistance are available on request.Connection can be made in three-wire or four-wire circuits if required.The resistance thermometers listed are examples of those that canbe ordered.

RepairsRepairs on resistance thermometers are carried out at GüntherGmbH; however, due to high assembly costs, such repairs arefrequently uneconomical.

The fundamental values and limiting deviations of the resistancethermometers supplied by Günther GmbH comply with theDIN EN 60571 norm.

The examples of products available for ordering shown in thiscatalogue are a selection of appliances frequently used inpractice. The numerical code indicated on the back of theindividual components can be used to draw up the respectiveorder number of a standard thermal sensor, although not allof the possible combinations of numbers and materials areuseful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components require technicalclarification. Please contact us if any specific problemsconcerning material and assembly occur during use. Themany years of experience we have gained should enable usto find the best possible solution for your specific problem.

1 x Pt 100 resistance thermometer with a Type Bconnection head and a G 3/4 A mounting thread

Product group: 50- WMSGünther Art. No.: 50-92046102-0750

Connection head: Type BProtection tube: ø 15 x 3 mm, material no. 1.4571Measurement insert: 1 x Pt 100 two-wire circuit, ø 3.0 mmNominal length: 750 mmFastening: G 3/4 A mounting thread, steel, zinc-coatedSensor point: Tapered, stainless steel, ø 6 x 60 mmTemperature range: 0 - 400°C

Limiting deviation: Class B in accordance with DIN EN 60751

Edition english 002 Product group 50-WMS Page 1 of 3

Nominal length

Installationlength

Page 57: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

50 - WMS // Straight resistance thermometers with a metal protection tubeand a built-in measurement insert

More order samples:

1 x Pt 100 two-wire circuit resistance thermometer witha Type B connection head and a stop flange

Product group: 50-WMSGünther Art. No.: 50-20004312-0600.V1

Connection head: Type AUZHProtection tube: ø 22 x 2 mm, material no. 1.4571Measurement insert: 1 x Pt 100 3-wire circuit, ø 6.0 mm,

inst. length=535 mmNominal length: 600 mmFastening: G 1 A gasproof mounting thread

made of steelTemperature range: 0 - 400°CLimiting deviation Class B in accordance with DIN EN 60751Feature: Built-in head transmitter, analogue 4 - 20 mA

Product group: 50-WMSGünther Art. No.: 50-39006401-1300

Connection head: Type BProtection tube: ø 15 x 2 mm, material no. 1.4762Measurement insert: 1 x Pt 100 two-wire circuit, ø 6.0 mm,

reinforcedNominal length: 1300 mmFastening: Stop flange, ø 15 mm

Temperature range: 0 - 400°C

Limiting deviation: Class B in accordance with DIN EN 60751

1 x Pt 100 three-wire circuit resistance thermometer witha Type AUZH connection head and a G 1 A mounting thread

Edition english 002 Product group 50-WMS Page 2 of 3

Nominal length

Nominal length

Page 58: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

50 - WMS // Straight resistance thermometers with a metal protection tubeand a built-in measurement insert

More order samples:

1 x Pt 100 two-wire circuit resistance thermometer with a Type Bconnection head and mounting thread, enamelled protection tube

1 x Pt 100 two-wire circuit resistance thermometer witha Type B connection head and a stop flange, measurementinsert freely protruding

Product group: 50-WMSGünther Art. No.: 50-99500073-0500

Connection head: Type BProtection tube: ø 15 x 2 x 430 mm, material no. 1.0305Measurement insert: 1 x Pt 100 two-wire circuit, ø 6.0 mm

(protruding freely 70 mm from the boredbase of the thermowell)

Nominal length: 500 mmFastening: Stop flange, ø 15 mm

Temperature range: 0 - 400°C

Limiting deviation: Class B in accordance with DIN EN 60751

Product group: 50-WMSGünther Art. No.: 50-99500084-0710

Connection head: Type BProtection tube: ø 15 x 2 mm, steel (fire-enamelled)Measurement insert: 1 x Pt 100 two-wire circuit, ø 6.0 mm,

installation length=735 mmNominal length: 710 mmFastening: G 1/2 A gasproof mounting thread

made of steelTemperature range: 0 - 400°C

Limiting deviation: Class B in accordance with DIN EN 60751

Edition english 002 Product group 50-WMS Page 3 of 3

Nominal lengthNominal length

Page 59: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Fastening Stop flange 1Mounting thread 2Stop flange/counter flange 3None 0

HeadA 1 B 6AUS 2 BUS 7AUZ 3 BUZ 8AUZH 4 BUZH 9AUSH 5 BBK 0

Sensor pointNot tapered 0 Tapered to 10 mm 5Tapered to 15 mm 1 Tapered to 8 mm 6Tapered to 12 mm 2Tapered to 9 mm 3Tapered to 6 mm 4 Tapered other 9

Custom designs: 5 0 - 9 9 5 0 x x x x -

Consecutive no. Nominal length / mm

50 - WMS // Straight resistance thermometers with a metal protection tubeand a built-in measurement insert

Pt 100 ohm, metal + sheath 5 0 - -

Nominal length / mmOuter protection tube material / dimensions

Material numberø [mm] 1.0305 1.4571 1.4893 1.4762 1.48419 x 1 0 1 1 1 2 1 3 1 4 19 x 1.5 0 2 1 2 2 2 3 2 4 2

10 x 1 0 3 1 3 2 3 3 3 4 310 x 1.5 0 4 1 4 2 4 3 4 4 411 x 1 0 5 1 5 2 5 3 5 4 511 x 1.5 0 6 1 6 2 6 3 6 4 612 x 1 0 7 1 7 2 7 3 7 4 712 x 2.5 0 8 1 8 2 8 3 8 4 815 x 2 0 9 1 9 3 9 3 9 4 922 x 2 1 0 2 0 3 0 4 0 5 015 x 3 9 1 9 2 9 4 9 5 9 6

Sheath measurement insert Rigid model

Sheath ø [mm] 2,0 3,0 4,5 6,0 6,0 6,0 8,0 8,0Point ø [mm] 2,0 3,0 4,5 6,0 8,0 10,0 8,0 10,0

Circuit1xPt100 Ohm2-wire 00 10 20 30 40 50 60 70 801xPt100 Ohm3-wire 01 11 21 31 41 51 61 71 811xPt100 Ohm4-wire 02 12 22 32 42 52 62 72 822xPt100 Ohm2-wire 03 13 23 33 43 53 63 73 832xPt100 Ohm3-wire 04 14 24 34 44 54 64 74 843xPt100 Ohm2-wire 05 15 25 35 45 55 65 75 852xPt100 Ohm4-wire 06 16 26 36 46 56 66 76 86

Inner tube None 0C530 ceramic material 1C610 gastight ceramic 2C799 Aluminium oxide 3

Page 60: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

52 - WOS // Sheath resistance thermometers without protection tube/thermowell

52-WOS

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 61: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

52 - WOS // Sheath resistance thermometers without protection tube/thermowell

Order sample:Sheath resistance thermometers are used in virtually all areas ofindustry.They are primarily used for measuring temperatures in pipe systems,containers, machines, furnaces, laboratories and plants and arevery often the ideal solution for problems, depending on the choiceof size and type.

For sensors of this type the resistor (1 x Pt 100 ohm or 2 x Pt 100ohm) is connected by means of 2, 4 or 6 supply lines (innerconductors) which are firmly pressed into ceramic powder. Theouter protective sheath is usually made of stainless steel witha diameter of 1.6 to 6.0 mm.

Sheath resistance thermometers have numerous advantages thanksto their design:

The small size and their flexibility enable temperatures to be measured in places which are difficult to access.Response times are short as a result of a compact design.Flexibility over the length of the sheathed cable, except forthe sensor point.

Electric properties

leakage resistance ≥ 1000 M / / testing voltage 500 V DC(for 3.0 mm to 6.0mm)leakage resistance ≤ 50M / test voltage 100 V DC(for 1.6 mm and 2.0 mm)

Sheath resistance thermometers are thermoelectric voltage-free,i.e. the thermoelectric voltage is ≤10 µV at 200°C.

The resistance values and limiting deviations of the resistancethermometers supplied by Günther GmbH comply with theDIN EN 60751 norm.

The examples of products available for ordering shown in thiscatalogue are a selection of appliances frequently used in practice.The numerical code indicated on the back of the individualcomponents can be used to draw up the respective order numberof a standard thermal sensor, although not all of the possiblecombinations of numbers and materials are useful or technicallyviable.Special numbers are developed by us for special thermal sensorswhose construction and components require technical clarification.Please contact us if any specific problems concerning materialand assembly occur during use. The many years of experiencewe have gained should enable us to find the best possible solutionfor your specific problem.

2 x Pt 100 2-wire circuit sheath resistance thermometerwith a Type DL connection head

Günther Art. No.: 52-20402399-0250

Connection head: Type DL with anM10 x 1 / IP 65 connection thread

Resistance: 2 x Pt 100 2-wire circuitSheath: Stainless steel 1.4541, ø 4.5 mmFastening: None

Nominal length: 250 mmTemperature range: -40 +400°CLimiting deviation: Class B in accordance with

DIN EN 60751Option: With a supply line connected,

4 x 0.22 mm2 PVC-PVC

Edition english 002 Product group 52-WOS Page 1 of 3

Nominal length

Page 62: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

52 - WOS // Sheath resistance thermometers without protection tube/thermowell

More order samples:

1 x Pt 100 2-wire circuit sheath resistance thermometer witha Lemo coupler connected

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in thecatalogue under 99-EZT.

Günther Art. No.: 52-35151041-0500

Connection: Lemo coupler, size 1, gold-plated contacts

Resistance: 1 x Pt 100 2-wire circuitSheath: Stainless steel 1.4541, ø 3.0 mmFastening: M8x1 1.4571 screw fastening with

a Teflon thrust collarNominal length: 500 mmTemperature range: -200 +600°CLimiting deviation: Class B in accordance with DIN EN 60751Feature: None

Resistance thermometer with a Type NA connection headand a 1 x Pt100 2-wire circuit measurement insert anda screw fastening and an angle plate

Günther Art. No.: 52-99520115-0300

Connection head: Type NAProtection tube: NoneResistance: 1 x Pt 100 2-wire circuitSheath: Stainless steel 1.4541, ø 6.0 mmNominal length: 300 mmFastening: 1.4571 G 1/4 A screw fastening

with a Teflon ring and counter-nut,retaining plate made of 1.4571,60 x 35 mm

Temperature range: -30 +150°CLimiting deviation: Class B in accordance with DIN EN 60751Feature: Digital measuring transducer

fitted in the head,OUT 4 - 20 mA for -30 - 150°C

Edition english 002 Product group 52-WOS Page 2 of 3

Nominal length

Nominal length

Page 63: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Günther Art. No.: 52-20103499-0500

Connection head: Type B with a M24 x 1.5connection thread + counter-screw

Resistance: 2 x Pt 100 3-wire circuitSheath: Stainless steel 1.4541, ø 6.0 mmFastening: G 1/2 A screw fastening, made of

1.4571 with a Teflon thrust collarNominal length: 500 mmTemperature range: -200 +600°CLimiting deviation: Class B in accordance with DIN EN 60751

52 - WOS // Sheath resistance thermometers without protection tube/thermowell

More order samples:

1 x Pt 100 4-wire circuit sheath resistance thermometerwith a Copper supply line connected

2 x Pt 100 3-wire circuit sheath resistance thermometerwith a Type B connection head

Plug-in connections, connections, screw joints, compensation cables and accessories can be found in the catalogueunder 99-EZT.

Günther Art. No.: 52-40151241-2000

Connection: Cable transition sleeve made of stainless steel and 1.5 m supply line 4x0.22 mm2, Silicone insulated

Resistance: 1 x Pt 100 4-wire circuitSheath: Stainless steel 1.4541, ø 3.0 mmFastening: M8x1 screw fastening made of

1.4571 with a Teflon thrust collar

Nominal length: 2000 mmTemperature range: -40 +400°CLimiting deviation: Class B in accordance with

DIN EN 60751Feature: Anti-kink spring made of stainless steel

fastened at the cable transition

Edition english 002 Product group 52-WOS Page 3 of 3

Nominal length

Nominal length

Page 64: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Sheath measurement inserts

Sheath ø [mm] 2.0 3.0 4.5 6.0 6.0 6.0 8.0 8.0Point ø [mm] 2.0 3.0 4.5 6.0 8.0 10.0 8.0 10.0

Circuit1xPt100 ohm2-wire 00 10 20 30 40 50 60 701xPt100 ohm3-wire 01 11 21 31 41 51 61 711xPt100 ohm4-wire 02 12 22 32 42 52 62 722xPt100 ohm2-wire 03 13 23 33 43 53 63 732xPt100 ohm3-wire 04 14 24 34 44 54 64 743xPt100 ohm2-wire 05 15 25 35 45 55 65 752xPt100 ohm4-wire 06 16 26 36 46 56 66 76

FasteningAttachment screw fastening: Made of Steel / Stainless steel

(Tapered ring, mat. no. 1.4541)M 8 x 1 for sheath ø 1.0-3.0 mm 11 21G 1/8 A for sheath ø 1.0-3.0 mm 12 22G 1/4 A for sheath ø 4.5-8.0 mm 13 23G 1/2 A for sheath ø 4.5-8.0 mm 14 24

(Tapered ring unit St. 35.8) Screwed socket combinedM 8 x 1 for sheath ø 1.0-3.0 mm 51 31 G 1/4 A 80G 1/8 A for sheath ø 1.0-3.0 mm 52 32 G 3/8 A 81G 1/4 A for sheath ø 4.5-8.0 mm 53 33 G 1/2 A 82G 1/2 A for sheath ø 4.5-8.0 mm 54 34 G 1 A 83

M 20 x 1.5 84M 18 x 1.5 85

(Teflon thrust collar) M 14 x 1.5 86M 8 x 1 for sheath ø 1.0-3.0 mm 61 41G 1/8 A for sheath ø 1.0-3.0 mm 62 42 No fastening 99G 1/4 A for sheath ø 4.5-8.0 mm 63 43G 1/2 A for sheath ø 4.5-8.0 mm 64 44 Other 88

Custom designs: 5 2 - 9 9 5 2 x x x x -

Consecutive no. Nominal length / mm

52 - WOS // Sheath resistance thermometers without protection tube/thermowell

Sheath resistance thermometer 5 2 - -

Nominal length / mmContact terminations:

Connection head Connection headwith a connection thread with a connecting diameter of 15.3 mmB (M24 x 1.5) 20 10 B 25 10BUS (M24 x 1.5) 20 15 BUS 25 15BUSH (M24 x 1.5) 20 20 BUSH 25 20BUZ (M24 x 1.5) 20 25 BUZ 25 25BUZH (M24 x 1.5) 20 30 BUZH 25 30BBK (M24 x 1.5) 20 35 BBK 25 35DL (MA) (M10 x1) 20 40

Joining elementsPlug CouplerLemo Size 0 30 10 Lemo Size 0 35 10Lemo Size 1 30 15 Lemo Size 1 35 15Lemo Size 2 30 20 Lemo Size 2 35 20Lemo Size 3 30 25 Lemo Size 3 35 25Standard 30 30 Standard 35 30Miniature 30 35 Miniature 35 35High-temp standard 30 40 High-temp standard 30 40 High-temp miniature 30 45 High-temp miniature 30 45

Cable transition sleeve + compensation circuit 4X XX(XXX = length of the compensation circuit in XX.X m)

Page 65: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

53-WHD

53 - WHD // Weld in resistance thermometers with a D-type protective sleeve

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 66: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

53 - WHD // Weld in resistance thermometers with a D-type protective sleeve

Resistance thermometers with welded sleeves are used for measuringtemperatures in gaseous and in liquid media such as air, steam,water, oil, etc. at high flow velocities and high pressures.Special welded sleeves are suitable for pressures of up to 700 bar.The fittings of this assembly are equipped with replaceable sheathsensors.The most significant component is a protective sleeve made of high-quality, solid metallic material which is welded into the respectivesystem. In this case the protective sleeve and the system should bemade of the same material.Available space at the place of use and stress levels to be expectedwill determine the choice of the most suitable protective sleeve. Theservice life of the protective sleeve depends on numerous factorssuch as temperature, pressure, the respective medium for use,installation position (horizontal/vertical), thermowell material and theflow past situation.

Guidelines for the working stability of the protective sleeves in termsof pressure and temperature can be seen in the DIN 43772 loaddiagrams.

It is particularly the question of chemical stability that will need tobe checked on carefully for each individual situation. Frequently itis only after operation tests have been carried out that informationis gained, since even minor impurities in the surrounding media canhave a considerable effect on the behaviour of the protective sleeves.

Most suitable areas of application:

Containers and pipings

Apparatus and machines

Laboratories

Test ranges

Process technology

Energy production and heat distribution

Food and beverages production

Machines and plant construction

The examples of products available for ordering shown in thiscatalogue are a selection of appliances frequently used in practice.The numerical code indicated on the back of the individualcomponents can be used to draw up the respective order numberof a standard thermal sensor, although not all of the possiblecombinations of numbers and materials are useful or technicallyviable.Special numbers are developed by us for special thermal sensorswhose construction and components require technical clarification.Please contact us if any specific problems concerning materialand assembly occur during use. The many years of experiencewe have gained should enable us to find the best possible solutionfor your specific problem.

2 x Pt 100 three-wire circuit welded resistancethermometers with a Type B connection head,M18 x 1.5 connection thread and a D2-type weldedsleeve

Product group: 53-WHDGünther Art. No.: 53-10022134-0200/0140

Connection head: Type B (M24 x 1.5)Thermowell: D2 welding sleeve, mat. no. 1.4571Neck pipe: ø 11 x 2 x 140 mm, material no. 1.4571Measurement insert: 2 x Pt 100 three-wire circuit, ø 6.0 mmThermowell length: 200 mmFastening: None

Temperature range: 0 - 400°C

Limiting deviation: Class B in accordance with DIN EN 60751

Order sample:

Edition english 002 Product group 53-WHD Page 1 of 2

Neck pipe length

Shaft length

Cone length

Thermowell length

Page 67: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

53 - WHD // Weld in resistance thermometers with a D-type protective sleeve

More order samples:

1 x Pt 100 3-wire circuit resistance thermometer with a Type BUZHconnection head, neck tube and a D4-type weld in sleeve made ofheat-resisting steel

1 x Pt 100 4-wire circuit resistance thermometerwith a Type BUZH connection head, neck tube and awelded sleeve made of stainless steel

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Product group: 53-WHDGünther Art. No.: 53-99530021-0070/0080

Connection head: Type BUZH (M24 x 1.5)Protection tube: Welding sleeve, mat. no. 1.4571 with

IG M14 x1,5, overall length = 70 mm,cone length = 25 mm

Neck pipe: ø 11 x 1 x 80 mm, material no. 1.4571Measurement insert: 1 x Pt 100 four-wire circuit, ø 6.0 mmInstallation length: 70 mmFastening: NoneTemperature range: 0 - 400°CLimiting deviation: Class B in accordance with

DIN EN 60751Feature: Digital measuring transducer

fitted in the head, 4 - 20 mA,equivalent to 0 - 100°C

Product group: 53-WHDGünther Art. No.: 53-70011231-0200/0140

Connection head: Type BUZH (M24 x 1.5)Protective sleeve: D4 welding sleeve, mat. no. 1.7335Neck pipe: ø 11 x 2 x 140 mm, material no. 1.0305,

zinc-coatedMeasurement insert: 1 x Pt 100 three-wire circuit, ø 6.0 mmInstallation length: 200 mmFastening: NoneTemperature range: 0 - 400°CLimiting deviation: Class B in accordance with DIN EN 60751Feature: Digital measuring transducer

fitted in the head, 4 - 20 mA,equivalent to 0 - 400°C

Edition english 002 Product group 53-WHD Page 2 of 2

Neck pipe length

Thermowell length

Neck pipe length

Installation length

Page 68: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Connection head

B (M24 x 1.5) 1 BUSH 6BUS 2 BUZH 7BUZ 3 NA 8BBK 4 DL / MA (M10 x 1) 9Other 5 0

Custom designs: 5 3 - 9 9 5 3 x x x x -

Consecutive no. Installation length / neck pipe lengthin mm

53 - WHD // Weld in resistance thermometers with a D-type protective sleeve

Pt 100 Ω, metal + sheath 5 3 - -

Installation length / Neck pipe length in mm

Blank flange St37-2 1.4571 C22.8in acc. with DIN 2527

DN 10 PN 16 1 0 2 0 3 0 NoneDN 15 PN 16 1 1 2 1 3 1DN 20 PN 16 1 2 2 2 3 2 0 0DN 25 PN 16 1 3 2 3 3 3DN 32 PN 16 1 4 2 4 3 4DN 40 PN 16 1 5 2 5 3 5DN 50 PN 16 1 6 2 6 3 6 OtherDN 65 PN 16 1 7 2 7 3 7DN 80 PN 16 1 8 2 8 3 8 9 9DN 100 PN 16 1 9 2 9 3 9

Neck pipe in acc. with DIN 43767

With M24 x 1.5 / M18 x 1.5 screw fittings Galvanised steel 1With M24 x 1.5 / M18 x 1.5 screw fittings Stainless steel 2With M24 x 1.5 / M14 x 1.5 screw fittings Galvanised steel 3With M24 x 1.5 / M14 x 1.5 screw fittings Stainless steel 4None 0Other 9

Welded protection tubes in acc. with DIN 43763

D1 Cone length = 65 mm, Shaft length = 50 mm, Thermowell length = 140 mm, ø 24 mm 10 20 30D2 Cone length = 125 mm, Shaft length = 50 mm, Thermowell length = 200 mm, ø 24 mm 11 21 31D4 Cone length = 65 mm, Shaft length = 110 mm, Thermowell length = 200 mm, ø 24 mm 12 22 32D5 Cone length = 125 mm, Shaft length = 110 mm, Thermowell length = 260 mm, ø 24 mm 13 23 33

DS Cone length = 65 mm, Shaft length = 50 mm, Thermowell length = 140 mm, ø 18 mm 15 25 35DS Cone length = 40 mm, Shaft length = 50 mm, Thermowell length = 115 mm, ø 18 mm 16 26 36No thermowell (sheath freely protruding) 00Other 99

1.73

35

1.45

71

1.54

15

Sheath measurement inserts

Sheath ø [mm] 2.0 3.0 4.5 6.0 6.0 6.0 8.0 8.0Point ø [mm] 2.0 3.0 4.5 6.0 8.0 10.0 8.0 10.0

Circuit1xPt100 Ω2-wire 00 10 20 30 40 50 60 701xPt100 Ω3-wire 01 11 21 31 41 51 61 711xPt100 Ω4-wire 02 12 22 32 42 52 62 722xPt100 Ω2-wire 03 13 23 33 43 53 63 732xPt100 Ω3-wire 04 14 24 34 44 54 64 743xPt100 Ω2-wire 05 15 25 35 45 55 65 752xPt100 Ω4-wire 06 16 26 36 46 56 66 76

Rigid design:

80

81

82

83

84

85

86

Page 69: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

54-WFL

54 - WFL // Resistance thermometers with a welded on blank flange

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 70: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

54 - WFL // Resistance thermometers with a welded on blank flange

Resistance thermometers with a welded on blank flange areused for measuring temperatures in gaseous and in liquid orplastic media such as air, steam, water or oil.

A blank flange welded onto the thermowell ensures that sensorsof this kind can be securely fastened to the walls of pressureand vacuum equipment, for example in power plants and inchemical plants. The protection fittings at the place of installationcan remain in place even if the sensor probe needs to be replacednow and then. This ensures that operation does not need to beinterrupted.

Changes in temperature can be detected very quickly if sensorswith a tapered thermowell point are used.

Most suitable areas of application:

Containers and pipings

Apparatus and machines

Laboratories

Test ranges

Process technology

Energy production and heat distribution

Food and beverages production

Machines and plant construction

Precision resistors with a tight tolerance (e.g. 1/3 DIN, 1/10 DINor Class A in accordance with DIN EN 60751) are used for specialapplications (precision, long-term stability, etc.).

The resistance values and limiting deviations of our resistancethermometers comply with the DIN EN 60751 norm.

The examples of products available for ordering shown inthis catalogue are a selection of appliances frequently usedin practice. The numerical code indicated on the back ofthe individual components can be used to draw up therespective order number of a standard thermal sensor,although not all of the possible combinations of numbersand materials are useful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components requiretechnical clarification. Please contact us if any specificproblems concerning material and assembly occur duringuse. The many years of experience we have gained shouldenable us to find the best possible solution for your specificproblem.

1 x Pt 100 3-wire circuit straight flanged resistancethermometer with a DN 25 PN 16 blank flange, Type C

Order sample:

Product group: 54-WFLGünther Art. No.: 54-63123105-0500/0130

Connection head: Type BUZ (M24 x 1.5)Neck tube: ø 15 x 2 mm, material no. 1.4571Protection tube: ø 15 x 2 mm, material no. 1.4571Sensor point: ø 10 x 1.5 x 40 mmProcess connection: DN 25 PN 16 blank flange, Type C,

1.4571, welded onto the thermowell

Measurement insert: 1 x Pt 100 three-wire circuit, ø 6.0 mmTemperature range: 0 - 600°C

Limiting deviation: Class B in accordance with DIN EN 60751

Edition english 002 Product group 54-WFL Page 1 of 2

Neck pipe length

Installation length

Page 71: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

More order samples:

Günther GmbH · Temperaturmesstechnik

Product group: 54-WFLGünther Art. No.: 54-99540054-0100/0120

Connection head: Style BUZH (M24 x 1.5)Protection tube: ø 11 x 2 mm, material no. 1.4571Sensor point: Not taperedProcess connection: DN 25 PN 16 blank flange,

mat. no. 1.4571Installation length: 100 mmNeck pipe length: 120 mmMeasurement insert: 1 x Pt 100 three-wire circuit, ø 6.0 mmTemperature range: 0 - 180°CFeature: Halar coating (E-CTFE)Limiting deviation: Class B in accordance with

DIN EN 60571

54 - WFL // Resistance thermometers with a welded on blank flange

2 x Pt 100 2-wire circuit resistance thermometer witha Type BUZH connection head and a blank flangewelded on

1 x Pt 100 3-wire circuit resistance thermometer witha Type BUZH connection head and a DN 25 PN 16blank flange welded on

Product group: 54-WFLGünther Art. No.: 54-83315070-0200/0150

Connection head: Style BUZH (M24 x 1.5)Protection tube: ø 12 x 1.5 mm, material no. 1.0305Sensor point: Not taperedProcess connection: DN 40 PN 16 blank flange,

mat. no. 1.0037Installation length: 200 mmNeck pipe length: 150 mmMeasurement insert: 2 x Pt 100 two-wire circuit, ø 6.0 mmTemperature range: 0 - 600°C

Limiting deviation: Class B in accordance withDIN EN 60751

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Edition english 002 Product group 54-WFL Page 2 of 2

Installation length

Neck pipe length

Installation length

Neck pipe length

Halar coating(E-CTFE)

Page 72: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Sheath measurement inserts

Sheath ø [mm] 2.0 3.0 4.5 6.0 6.0 6.0 8.0 8.0Point ø [mm] 2.0 3.0 4.5 6.0 8.0 10.0 8.0 10.0

Circuit1xPt100 Ω2-wire 00 10 20 30 40 50 60 70 801xPt100 Ω3-Leiter 01 11 21 31 41 51 61 71 811xPt100 Ω4-wire 02 12 22 32 42 52 62 72 822xPt100 Ω2-Leiter 03 13 23 33 43 53 63 73 832xPt100 Ω3-wire 04 14 24 34 44 54 64 74 843xPt100 Ω2-wire 05 15 25 35 45 55 65 75 852xPt100 Ω4-wire 06 16 26 36 46 56 66 76 86

Design

Standard [protection tube not tapered] 0

Fast response [protection tube tapered]Tube point 15 mm ø 1 Tube point 10 mm ø 5Tube point 12 mm ø 2 Tube point 8 mm ø 6Tube point 9 mm ø 3Tube point 6 mm ø 4 Other 9

Blank flange in acc. St37-2 1.4571 C22.8 Alloy C4 with DIN 2527

DN 10 PN 16 1 0 2 0 3 0 6 7 NoneDN 15 PN 16 1 1 2 1 3 1 6 8DN 20 PN 16 1 2 2 2 3 2 6 9 0 0DN 25 PN 16 1 3 2 3 3 3 7 0DN 32 PN 16 1 4 2 4 3 4 7 1DN 40 PN 16 1 5 2 5 3 5 7 2DN 50 PN 16 1 6 2 6 3 6 7 3 OtherDN 65 PN 16 1 7 2 7 3 7 7 4DN 80 PN 16 1 8 2 8 3 8 7 5 9 9DN 100 PN 16 1 9 2 9 3 9 7 6

Custom designs: 5 4 - 9 9 5 4 x x x x -

Consecutive no. Installation length / neck pipe lengthin mm

54 - WFL // Resistance thermometers with a welded on blank flange

Pt 100 Ω with a blank flange 5 4 - -

Installation length / neck pipe lengthin mm

Outer protection tube material / dimensions

1.0305 1.4571 1.4762 1.4841 2.4816 Kanthal C4 alloy

6 x 0.75 0 1 1 2 2 3 3 4 4 5 5 6 6 7 8 x 1 0 2 1 3 2 4 3 5 4 6 5 7 6 8 9 x 1 0 3 1 4 2 5 3 6 4 7 5 8 6 910 x 1.5 0 4 1 5 2 6 3 7 4 8 5 9 7 011 x 1 0 5 1 6 2 7 3 8 4 9 5 0 7 111 x 2 0 6 1 7 2 8 3 9 4 0 6 1 7 212 x 1.5 0 7 1 8 2 9 3 0 5 1 6 2 7 312 x 2.5 0 8 1 9 2 0 4 1 5 2 6 3 7 415 x 2 0 9 1 0 3 1 4 2 5 3 6 4 7 515 x 3 0 0 2 1 3 2 4 3 5 4 6 5 7 622 x 2 1 1 2 2 3 3 4 4 5 5 6 6 7 7

Rigiddesign

Other99

Connection head

A 1 BUZ (M24 x 1.5) 62 BUSH (M24 x 1.5) 7

BBK (M24 x 1.5) 3 BUZH (M24 x 1.5) 8B (M24 x 1.5) 4 DL / MA (M10 x 1) 9BUS (M24 x 1.5) 5 0

Page 73: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

55-WES

55 - WES // Screw-in resistance thermometers

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 74: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

55 - WES // Screw-in resistance thermometers

Screw-in resistance thermometers are used for standardtemperature measurements in the low-pressure range for gaseous,liquid and plastic media, depending on the quality of thethermowell and the surrounding media, up to a temperatureof 850°C.

A screwed connecting piece welded onto the thermowell ensuresa stable process alignment of the sensors of this assembly.

The protective fittings are generally made of seamlessly extrudedstainless steel tubing with a welded in bottom round plate.

Changes in temperature can be detected very quickly if sensorswith a tapered thermowell point are used.

Most suitable areas of application:

Containers and pipings

Apparatus and machines

Laboratories

Test ranges

Process technology

Energy production and heat distribution

Food and beverages production

Machines and plant construction

Precision resistors with a tight tolerance (e.g. 1/3 DIN, 1/10 DINor Class A in accordance with DIN EN 60751) are used for specialapplications (precision, long-term stability, etc.).

The resistance values and limiting deviations of our resistancethermometers comply with the DIN EN 60751 norm.

The examples of products available for ordering shown inthis catalogue are a selection of appliances frequently usedin practice. The numerical code indicated on the back ofthe individual components can be used to draw up therespective order number of a standard thermal sensor,although not all of the possible combinations of numbersand materials are useful or technically viable.Special numbers are developed by us for special thermalsensors whose construction and components requiretechnical clarification. Please contact us if any specificproblems concerning material and assembly occur duringuse. The many years of experience we have gained shouldenable us to find the best possible solution for your specificproblem.

Order sample:

1 x Pt 100 2-wire circuit resistance thermometerwith a G 1/2 A screw-in thread

Product group: 55-WESGünther Art. No.: 55-13041701-0400/0140

Connection head: Type B (M24 x 1.5)Protection tube: ø 11 x 2 mm, material no. 1.4571Measurement insert: 1 x Pt 100 two-wire circuit, ø 6 mmInstallation length: 400 mmNeck pipe length: 140 mmFastening: G 1/2 A screwed socket, mat. no. 1.4571Sensor point: Not tapered, closedTemperature range: 0 - 400°C

Limiting deviation: Class B in accordance with DIN EN 60751

Edition english 002 Product group 55-WES Page 1 of 2

Neck pipe length

Installation length

Page 75: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

More order samples:

Günther GmbH · Temperaturmesstechnik

Product group: 55-WESGünther Art. No.: 55-73362101-0800/0100

Connection head: Type BUZH (M24 x 1.5) with PG 13.5(blue f.EX)

Protection tube: ø 15 x 3 mm, material no. 1.4571Measurement insert: 2 x Pt 100 2 two-wire circuit, ø 6.0 mmInstallation length: 800 mmNeck pipe length: 100 mmFastening: G 3/4 A screwed socket, mat. no. 1.4571Sensor point: Not taperedTemperature range: -200° - 600°CMeasuring transducer: Digital, set according to instructions,

4 - 20 mA outputLimiting deviation: Class B in accordance with DIN EN 60751

55 - WES // Screw-in resistance thermometers

2 x Pt 100 3-wire circuit resistance thermometer witha G 1/2 A screw-in thread, no protection tube

2 x Pt 100 2-wire circuit resistance thermometer witha BUZH head and a G3/4A screw-in thread

Product group: 55-WESGünther Art. No.: 55-13419900-1200

Connection head: Type B (M24 x 1.5)Protection tube: NoneMeasurement insert: 2 x Pt 100 3-wire circuit, ø 6mm,

resilient installation, protruding freelyfrom the socket

Installation length: 1200 mmFastening: G 1/2 A screwed socket, mat. no. 1.4571Temperature range: 0 - 400°CLimiting deviation: Class B in accordance with DIN EN 60751

Feature: Not pressure sealed at the head

Günther GmbH will calibrate your thermocouples in the company’s own calibration laboratory at favourable conditions.All calibrations are traceable to the national norms of the German Federal Physical-Technical Institute.

Edition english 002 Product group 55-WES Page 2 of 2

Neck pipe length

Installation length

Installation length

Page 76: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Sheath measurement inserts

Sheath ø [mm] 2.0 3.0 4.5 6.0 6.0 6.0 8.0 8.0Point ø [mm] 2.0 3.0 4.5 6.0 8.0 10.0 8.0 10.0

Circuit1xPt100 Ω2-wire 00 10 20 30 40 50 60 70 801xPt100 Ω3-wire 01 11 21 31 41 51 61 71 811xPt100 Ω4-wire 02 12 22 32 42 52 62 72 822xPt100 Ω2-wire 03 13 23 33 43 53 63 73 832xPt100 Ω3-wire 04 14 24 34 44 54 64 74 843xPt100 Ω2-wire 05 15 25 35 45 55 65 75 852xPt100 Ω4-wire 06 16 26 36 46 56 66 76 86

Outer protection tube material / dimensions

1.0305 1.4571 1.4762 1.4841 2.4816 Kanthal

6 x 0.75 0 1 1 2 2 3 3 4 4 5 5 6 8 x 1 0 2 1 3 2 4 3 5 4 6 5 7 9 x 1 0 3 1 4 2 5 3 6 4 7 5 810 x 1.5 0 4 1 5 2 6 3 7 4 8 5 911 x 1 0 5 1 6 2 7 3 8 4 9 5 011 x 2 0 6 1 7 2 8 3 9 4 0 6 112 x 1.5 0 7 1 8 2 9 3 0 5 1 6 212 x 2.5 0 8 1 9 2 0 4 1 5 2 6 315 x 2 0 9 1 0 3 1 4 2 5 3 6 415 x 3 0 0 2 1 3 2 4 3 5 4 6 522 x 2 1 1 2 2 3 3 4 4 5 5 6 6No protection tube 9 9 Other 8 8

Design

Standard [protection tube not tapered] 0

Fast response [protection tube tapered]Protection tube point 15 mm ø 1 Protection tube point 10 mm ø 5Protection tube point 12 mm ø 2 Protection tube point 8 mm ø 6Protection tube point 9 mm ø 3Protection tube point 6 mm ø 4 Other 9

Connection head

B (M24 x 1.5) 1 BUSH 6BUS 2 BUZH 7BUZ 3 NA 8BBK 4 DL / MA (M10 x 1) 9BFS 5 0

Custom designs: 5 5 - 9 9 5 5 x x x x -

Consecutive no. Installation length / Neck pipe lengthin mm

55 - WES // Screw-in resistance thermometers

Pt 100 Ω, metal + sheath 5 5 - -

Installation length / neck pipe lengthin mm

Neck pipe None 0 Present 1

Rigiddesign

Screwed plug

Screw joint, combined, M24 x 1.5 / G 1/2 A 1Screw joint, combined, M10 x 1 / G 1/2 A 2Screw joint G 1 A 3Screw joint G 1/2 A 4Screw joint M18x1,5 5Screw joint G 3/4 A 6Screw joint M20x1,5 7Other 9

Page 77: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

60-ESF71-KFT72-KFW

60 - ESF // Plug-in thermocouples or resistance thermometers with a bayonet nut connector

71 - KFT // Cable sensors: thermocouple model

72 - KFW // Cable sensors: resistance thermometer model

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 78: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

The constructive design of the three product groups specifiedabove are determined by user-related requirements, particularlysince the design is almost freely configurable.

Examples of applications are:measuring temperatures in pipelines, on the walls of containers,in or on machines and units, in injection moulds, in cold storages,in fluids and in any kind of semi-solid substance.

These temperature sensors are named in accordance with theirdesign, the type of fastening or where they are used: e.g.Bayonet sensors, plug-in sensors, screw-in sensors, insertionsensors, weld sensors, ambient sensors, surface sensors,contact sensors, pipe clamp sensors, acid sensors, etc.

Since a multitude of various products is available in this groupof products, we do not indicate any number codes for drawingup respective order numbers, since the technical details ofthese products will generally need to be clarified in advance.

We kindly ask you to provide us with your specific requirements,such as:type of sensor, required limiting deviations, quality anddimensions of the protective sleeve or the process connection,length of cable, operation temperature, connection threadif available, size of the cable, surrounding media, etc.

The many years of experience we have gained will enable usto find the best possible solution for your specific measuringtask.

Günther GmbH · Temperaturmesstechnik

60 - ESF // Plug-in thermocouples or resistance thermometers with a bayonet nut connector71 - KFT // Cable sensors: thermocouple model72 - KFW // Cable sensors: resistance thermometer model

Edition english 002 Product group 60-ESF/71-KFT/72-KFW Page 1 of 1

Page 79: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

92-THL93-AGL

92 - THL // Thermoelectric conductors

93 - AGL // Compensation cables

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 80: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Thermocouple type IEC 584 DIN 43714 ANSI MC 96.1

NiCr-Ni / K

Fe-CuNi / L

Fe-CuNi /J

Pt10Rh-Pt / S

Pt13Rh-Pt / R

Pt30Rh-Pt6Rh / B

NiCrosil-Nisil / N

Cu-CuNi / U

Cu-CuNi / T

92 - THL // Thermoelectric cables93 - AGL // Compensation cables

Thermoelectric cables and compensation cables are essentiallydifferentiated on the basis of the materials they are made of.

Thermoelectric cables are made of the respective originalthermocouple materials or of materials which have thesame nominal chemical composition as the correspondingthermocouples. For this reason thermoelectric cables aresuitable for use as trailing thermocouples after a measuringpoint has been completed. They are named in accordance withthe distinguishing letter of the respective thermocouple followedby an “X” (e.g. KX).

Compensation cables are made of replacement materials whichare not identical with the original thermocouple materials;however, up to a certain authorised temperature range, theydo have the same thermoelectric properties. They are namedin accordance with the identification letter of the respectivethermocouple followed by a “C” (e.g. KC).

Cable structure:Thermoelectric cables are produced both as strandedconductors and as solid conductors, generally with cross-sections of 0.22 mm2 to 1.50 mm2 or with diameters of 0.2 mmto 1.0 mm. Compensation cables are produced as strandedconductors, generally with cross-sections of 0.22 mm2 to1.50 mm2.

Tolerances, limiting deviations and colour marking:Cables for thermal conductors and compensation conductorscomply with DIN 43713. Thermoelectric voltages within anauthorised temperature range comply with DIN EN 60584-1.Limiting deviations for thermal and compensation conductorsare stipulated in DIN 43722. Precision category 1 applies forthermoelectric cables and category 2 applies for thermoelectriccables and for compensation cables (apart from thermocoupletypes U and L in accordance with DIN 43710, equivalent to± 3°C). The colour codes for cables which Günther-GmbH hasin stock comply with DIN 43722 (except for thermocouple typesU and L – in accordance with DIN 43714).

Selection criteria for thermoelectric cables andcompensation cables:A suitable choice of cable for a specific application dependsgreatly on influencing factors and on ambient conditions.

For example:thermal stability, stress, flexibility, resistance to moistureor aggressive media, cross-section of conductors, outerdimensions, flammability, electromagnetic compatibility (sheath)and many more. We suggest that you speak to us about yourspecific application. We will gladly give you advice andendeavour to offer you a conductor suitable for your particularapplication.

Product range:Günther-Gmbh supplies almost all of the widely-used thermaland compensation cables from stock. Special dimensions ordesigns can generally be procured at short notice. The articlenumbers for cables from our standard range are all listed inbold print on the following pages.

Colour index for compensation and thermoelectric cablesand for thermal plugs

The basic data for the individual thermocouples is the same for all of thespecifications indicated. Thermocouples U and L are only normed in DIN43710/1985. For new equipment and for retrofits we recommend that onlythermocouples in accordance with IEC 584 be used (T instead of U andJ instead of L). J and T type thermocouples are not identical with types Land U.

+ green / - whiteSheath: green

+ red / - greenSheath: green

+ yellow / - redSheath: yellow

+ red / - blueSheath: blue

+ black / - whiteSheath: black

+ red / - whiteSheath: white

+ red / - whiteSheath: white

+ orange / - whiteSheath: orange

+ orange / - whiteSheath: orange

+ grey / - whiteSheath: grey

+ pink / - whiteSheath: pink

+ brown / - whiteSheath: brown

+ red / - brownSheath: brown

+ white / - redSheath: black

+ black / - redSheath: green

+ black / - redSheath: green

+ grey / - redSheath: grey

Code letter Range Class 1 Range Class 2

J -40 ... 750°C ±1,5°C or 0,004·(t) -40 ... 750°C ±2,5°C or 0,0075·(t)

K -40 ... 1000°C ±1,5°C or 0,004·(t) -40 ... 1200°C ±2,5°C or 0,0075·(t)

T -40 ... 350°C ±0,5°C or 0,004·(t) -40 ... 350°C ±1,0°C or 0,0075·(t)

E -40 ... 800°C ±1,5°C or 0,004·(t) -40 ... 900°C ±2,5°C or 0,0075·(t)

S / R 0 ... 1600°C ±1,0°C or 0 ... 1600°C ±1,5°C or 0,0025·(t)

[1,0+0,003(t-1100)]°C

N -40 ... 1000°C ±1,5°C or 0,004·(t) -40 ... 1200°C ±2,5°C or 0,0075·(t)

B 600 ... 1700°C ±1,5°C or 0,0025·(t)

Limiting deviations in accordance with EN 60584-2 (comparison point 0°C)

The higher figure applies (t = number for the temperature in °C)

Edition english 002 Product group 92-THL/93-AGL Page 1 of 13

Page 81: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individually covered with fibreglass, stranded

Solid conductors

Individually coveredwith fibreglass

Jointly braidedwith fibreglass

Solid conductors

Individually covered with pure fibreglass, stranded

Solid conductors

92 - THL // Thermoelectric cables

Thermoelectric cable(impregnated coating)Covered with fibreglassG, stranded

- Thermal stability of the insulation material-40°C to +400°C

- Use in dry rooms at a low degree ofmechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø round, stranded 92-30202018-G 92-40202028-G 92-50202018-G 92-60202018-G2 x 0.5 mm ø round, stranded 92-30205018-G 92-40205028-G 92-50202018-G 92-60205018-G2 x 1.0 mm ø round, stranded 92-30210018-G 92-40210028-G 92-50210018-G 92-60210018-G

Thermoelectric cable(impregnated coating)Covered with fiberglass - Braidedwith fibreglassGG, oval

- Thermal stability of the insulation material-40°C to +400°C

- Use in dry rooms at a low degreeof mechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø oval 92-30202015-GG 92-40202025-GG 92-50202015-GG 92-60202015-GG2 x 0.5 mm ø oval 92-30205015-GG 92-40205025-GG 92-50205015-GG 92-60205015-GG2 x 1.0 mm ø oval 92-30210015-GG 92-40210025-GG 92-50210015-GG 92-60210015-GG

Thermoelectric cable(impregnated coating)Covered with pure fibreglassR, stranded

- Thermal stability of the insulation material-40°C to +700°C

- Use in dry rooms at a low degreeof mechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø round, stranded 92-30202018-R 92-40202028-R 92-50202018-R 92-60202018-R2 x 0.5 mm ø round, stranded 92-30205018-R 92-40205028-R 92-50205018-R 92-60205018-R2 x 1.0 mm ø round, stranded 92-30210018-R 92-40210028-R 92-50210018-R 92-60210018-R

Edition english 002 Product group 92-THL/93-AGL Page 2 of 13

Page 82: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individually coveredwith pure fibreglass

Jointly braidedwith pure fibreglass

Solid conductors

Individually coveredwith silicate fibre

Jointly braided with silicate fibre+ impregnated coating

Solid conductors

Individually coveredwith ceramic fibre

Jointly braidedwith ceramic fibre

Solid conductors

92 - THL // Thermoelectric cables

Thermoelectric cable(impregnated coating)Covered with pure fibreglass – Braidedwith pure fibreglassRR, oval

- Thermal stability of the insulation material-40°C to +700°C

- Use in dry rooms at a low degreeof mechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø oval 92-30202015-RR 92-40202025-RR 92-50202015-RR 92-60202015-RR2 x 0.5 mm ø oval 92-30205015-RR 92-40205025-RR 92-50205015-RR 92-60205015-RR2 x 1.0 mm ø oval 92-30210015-RR 92-40210025-RR 92-50210015-RR 92-60210015-RR

Thermoelectric cable(impregnated coating)Covered with silicate fibre – Braidedwith silicate fibreLL, oval

- Thermal stability of the insulation material-40°C to +1000°C

- Use in dry rooms at a low degreeof mechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø oval 92-30202015-LL 92-40202025-LL 92-50202015-LL 92-60202015-LL2 x 0.5 mm ø oval 92-30205015-LL 92-40205025-LL 92-50205015-LL 92-60205015-LL2 x 1.0 mm ø oval 92-30210015-LL 92-40210025-LL 92-50210015-LL 92-60210015-LL

Thermoelectric cableCovered with ceramic fibre – Braidedwith ceramic fibreKK, oval

- Thermal stability of the insulation material-40°C to +1200°Ctemporarily up to +1400°C

- Use in dry rooms at a low degreeof mechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø oval 92-30202015-KK 92-40202025-KK 92-50202015-KK 92-60202015-KK2 x 0.5 mm ø oval 92-30205015-KK 92-40205025-KK 92-50205015-KK 92-60205015-KK2 x 1.0 mm ø oval 92-30210015-KK 92-40210025-KK 92-50210015-KK 92-60210015-KK

Edition english 002 Product group 92-THL/93-AGL Page 3 of 13

Page 83: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individually PVC-extruded, stranded

Jointly PVC-extrudedSolid conductors

Individually silicon-extruded, stranded

Jointly silicon-extrudedSolid conductors (mm ø)or stranded conductors (mm2)

Individually FEP-extruded, stranded

Solid conductors (mm ø)or stranded conductors (mm2)

92 - THL // Thermoelectric cables

Thermoelectric cableIndividually PVC-extruded -Jointly PVC-extrudedJJ, round

- Thermal stability of the insulation material -10°C to +105°C

- Use in a damp environment at a medium degreeof mechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø round, stranded 92-30202018-JJ 92-40202028-JJ 92-50202018-JJ 92-60202018-JJ2 x 0.5 mm ø round, stranded 92-30205018-JJ 92-40205028-JJ 92-50205018-JJ 92-60205018-JJ2 x 1.0 mm ø round, stranded 92-30210018-JJ 92-40210028-JJ 92-50210018-JJ 92-60210018-JJ

Thermoelectric cableIndividually silicone-extruded -Jointly silicone-extrudedSS, round

- Thermal stability of the insulation material-45°C to +180°C

- Use in a damp environment and at a medium degree of mechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø round, stranded 92-30202018-SS 92-40202028-SS 92-50202018-SS 92-60202018-SS2 x 0.5 mm ø round, stranded 92-30205018-SS 92-40205028-SS 92-50205018-SS 92-60205018-SS2 x 1.0 mm ø round, stranded 92-30210018-SS 92-40210028-SS 92-50210018-SS 92-60210018-SS

2 x 0.22 mm2 round, stranded 92-30202214-SS 92-40202224-SS 92-50202214-SS 92-60202214-SS2 x 0.5 mm2 round, stranded 92-30205014-SS 92-40205024-SS 92-50205014-SS 92-60205014-SS2 x 1.0 mm2 round, stranded 92-30210014-SS 92-40210024-SS 92-50210014-SS 92-60210014-SS

Thermoelectric cableInsulated with Teflon (FEP)and strandedE, stranded

- Thermal stability of the insulation material-200°C to +205°C

- Use in a damp environment and for specialrequirements concerning resistance to chemicals

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø round, stranded 92-30202018-E 92-40202028-E 92-50202018-E 92-60202018-E2 x 0.5 mm ø round, stranded 92-30205018-E 92-40205028-E 92-50205018-E 92-60205018-E2 x 1.0 mm ø round, stranded 92-30210018-E 92-40210028-E 92-50210018-E 92-60210018-E

2 x 0.22 mm2 round, stranded 92-30202214-E 92-40202224-E 92-50202214-E 92-60202214-E2 x 0.5 mm2 round, stranded 92-30205014-E 92-40205024-E 92-50205014-E 92-60205014-E2 x 1.0 mm2 round, stranded 92-30210014-E 92-40210024-E 92-50210014-E 92-60210014-E

Edition english 002 Product group 92-THL/93-AGL Page 4 of 13

Page 84: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individually FEP-extruded

Solid conductors (mm ø)or stranded conductor (mm2)

Jointly FEP-extruded

Individually coveredwith fibreglass

Cable braid, galvanised steelwith a marker thread

Jointly braidedwith fibreglass

Strandedconductors

Individually TeflonFEP-extruded

Cables braid, galvanised steelwith a marker thread

Jointly braidedwith fibreglass

Strandedconductors

92 - THL // Thermoelectric cables

Thermoelectric cableIndividually Teflon FEP-extruded -Jointly FEP-extrudedEE, oval and round models, stranded

- Thermal stability of the insulation material-200°C to +205°C

- Use in a damp environment and for special requirements concerning resistance to chemicals

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.2 mm ø round, stranded 92-30202018-EE 92-40202028-EE 92-50202018-EE 92-60202018-EE2 x 0.5 mm ø oval 92-30205015-EE 92-40205025-EE 92-50205015-EE 92-60205015-EE2 x 1.0 mm ø round, stranded 92-30210018-EE 92-40210028-EE 92-50210018-EE 92-60210018-EE

2 x 0.22 mm2 round, stranded 92-30202014-EE 92-40202024-EE 92-50202014-EE 92-60202014-EE2 x 0.5 mm2 oval 92-30205011-EE 92-40205021-EE 92-50205011-EE 92-60205011-EE2 x 1.0 mm2 round, stranded 92-30210014-EE 92-40210024-EE 92-50210014-EE 92-60210014-EE

Thermoelectric cableFibreglass – Fibreglass – Wire braidGGP, oval and round models, stranded

- Thermal stability of the insulation material-200°C to +400°C

- Use in a dry environment and at high mechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.22 mm2 oval 92-30202011-GGP 92-40202021-GGP 92-50202011-GGP 92-60202011-GGP2 x 0.5 mm2 round, stranded 92-30205014-GGP 92-40205024-GGP 92-50205014-GGP 92-60205014-GGP2 x 1.0 mm2 round, stranded 92-30210014-GGP 92-40210024-GGP 92-50210014-GGP 92-60210014-GGP

Thermoelectric cableTeflon FEP - Fibreglass – Wire braidEGP, round

- Thermal stability of the insulation material -200°C to +205°C

- Use in a dry environment and at high mechanical stress

Cable Shape NiCr-Ni/K Fe-CuNi/L Fe-CuNi/J Nicrosil-Nisil/N+ green - white IEC 584/3 + red - blue DIN 43710 + black - white IEC 584/3 + pink - white IEC 584/3

2 x 0.22 mm2 round, stranded 92-30202014-EGP 92-40202024-EGP 92-50202014-EGP 92-60202014-EGP2 x 0.5 mm2 round, stranded 92-30205014-EGP 92-40205024-EGP 92-50205014-EGP 92-60205014-EGP2 x 1.0 mm2 round, stranded 92-30210014-EGP 92-40210024-EGP 92-50210014-EGP 92-60210014-EGP

Edition english 002 Product group 92-THL/93-AGL Page 5 of 13

Page 85: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individually coveredwith fibreglass

Cable braid, galvanised steelwith a marker thread

Jointly braidedwith fibreglass

Individually coveredwith fibreglass

Jointly coveredwith fibreglass

Stranded conductors

Strandedconductors

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.22 mm2 round 93-10202214-GGP 93-20202214-GGP 93-30202214-GGP 93-40202224-GGP2 x 0.5 mm2 round 93-10205014-GGP 93-20205014-GGP 93-30205014-GGP 93-40205024-GGP2 x 0.5 mm2 oval 93-10205011-GGP 93-20205011-GGP 93-30205011-GGP 93-40205021-GGP2 x 0.75 mm2 round 93-10207514-GGP 93-20207514-GGP 93-30207514-GGP 93-40207524-GGP2 x 0.75 mm2 oval 93-10207511-GGP 93-20207511-GGP 93-30207511-GGP 93-40207521-GGP2 x 1.5 mm2 oval 93-10215011-GGP 93-20215011-GGP 93-30215011-GGP 93-40215021-GGP4 x 0.5 mm2 round 93-10405014-GGP 93-20405014-GGP 93-30405014-GGP 93-40405024-GGP4 x 1.5 mm2 round 93-10415014-GGP 93-20415014-GGP 93-30415014-GGP 93-40415024-GGP

93 - AGL // Compensation cables

Compensation cableFibreglass - FibreglassGG, oval and round models, stranded

- Thermal stability of the insulation materialup to 200°C

- Use in dry rooms at a low degreeof mechanical stress

Compensation cableFibreglass – Fibreglass – Wire braidGGP, oval and round models, stranded

- Thermal stability of the insulation materialup to 400°C

- Use in dry rooms at high mechanical stress

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.22 mm2 round 93-50202214-GGP 93-60202214-GGP 93-70202244-GGP 93-80202244-GGP2 x 0.5 mm2 round 93-50205014-GGP 93-60205014-GGP 93-70205044-GGP 93-80205044-GGP2 x 0.5 mm2 oval 93-50205011-GGP 93-60205011-GGP 93-70205041-GGP 93-80205041-GGP2 x 0.75 mm2 round 93-50207514-GGP 93-60207514-GGP 93-70207544-GGP 93-80207544-GGP2 x 0.75 mm2 oval 93-50207511-GGP 93-60207511-GGP 93-70207541-GGP 93-80207541-GGP2 x 1.5 mm2 oval 93-50215011-GGP 93-60215011-GGP 93-70215041-GGP 93-80215041-GGP4 x 0.5 mm2 round 93-50405014-GGP 93-60405014-GGP 93-70405044-GGP 93-80405044-GGP4 x 1.5 mm2 round 93-50415014-GGP 93-60415014-GGP 93-70415044-GGP 93-80415044-GGP

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 1.5 mm2 oval 93-50215011-GG 93-60215011-GG 93-70215041-GG 93-80215041-GG4 x 1.5 mm2 round 93-50415011-GG 93-60415011-GG 93-70415041-GG 93-80415041-GG

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 1.5 mm2 oval 93-10215011-GG 93-20215011-GG 93-30215011-GG 93-40215021-GG4 x 1.5 mm2 round 93-10415011-GG 93-20415011-GG 93-30415011-GG 93-40415021-GG

Edition english 002 Product group 92-THL/93-AGL Page 6 of 13

Page 86: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individually PVC-extruded, stranded

Jointly PVC-extruded

Individually PVC-extruded, stranded

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.22 mm2 round 93-50202214-JJ 93-60202214-JJ 93-70202244-JJ 93-80202244-JJ2 x 0.5 mm2 round 93-50205014-JJ 93-60205014-JJ 93-70205044-JJ 93-80205044-JJ2 x 0.75 mm2 round 93-50207514-JJ 93-60207514-JJ 93-70207544-JJ 93-80207544-JJ2 x 1.5 mm2 round 93-50215014-JJ 93-60215014-JJ 93-70215044-JJ 93-80215044-JJ4 x 0.22 mm2 round 93-50402214-JJ 93-60402214-JJ 93-70402244-JJ 93-80402244-JJ4 x 0.5 mm2 round 93-50405014-JJ 93-60405014-JJ 93-70405044-JJ 93-80405044-JJ4 x 0.75 mm2 round 93-50407514-JJ 93-60407514-JJ 93-70407544-JJ 93-80407544-JJ4 x 1.5 mm2 round 93-50415014-JJ 93-60415014-JJ 93-70415044-JJ 93-80415044-JJ

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.22 mm2 round 93-10202214-JJ 93-20202214-JJ 93-30202214-JJ 93-40202224-JJ2 x 0.5 mm2 round 93-10205014-JJ 93-20205014-JJ 93-30205014-JJ 93-40205024-JJ2 x 0.75 mm2 round 93-10207514-JJ 93-20207514-JJ 93-30207514-JJ 93-40207524-JJ2 x 1.5 mm2 oval 93-10215011-JJ 93-20215011-JJ 93-30215011-JJ 93-40215021-JJ4 x 0.22 mm2 round 93-10402214-JJ 93-20402214-JJ 93-30402214-JJ 93-40402224-JJ4 x 0.5 mm2 round 93-10405014-JJ 93-20405014-JJ 93-30405014-JJ 93-40405024-JJ4 x 0.75 mm2 round 93-10407514-JJ 93-20407514-JJ 93-30407514-JJ 93-40407524-JJ4 x 1.5 mm2 round 93-10415014-JJ 93-20415014-JJ 93-30415014-JJ 93-40415024-JJ

93 - AGL // Compensation cables

Compensation cablePVCJ, stranded

- Thermal stability of the insulation material -10°C to +105°C- Use in a damp environment at a low degree

of mechanical stress

Compensation cablePVC - PVCJJ, oval and round models, stranded

- Thermal stability of the insulation material-10°C to +105°C

- Use in a damp environment at a low degreeof mechanical stress

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.5 mm2 round 93-10205014-J 93-20205014-J 93-30205014-J 93-40205024-J2 x 0.75 mm2 round 93-10207514-J 93-20207514-J 93-30207514-J 93-40207524-J2 x 1.0 mm2 round 93-10210014-J 93-20210014-J 93-30210014-J 93-40210024-J2 x 1.5 mm2 round 93-10215014-J 93-20215014-J 93-30215014-J 93-40215024-J

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.5 mm2 round 93-50205014-J 93-60205014-J 93-70205044-J 93-80205044-J2 x 0.75 mm2 round 93-50207514-J 93-60207514-J 93-70207544-J 93-80207544-J2 x 1.0 mm2 round 93-50210014-J 93-60210014-J 93-70210044-J 93-80210044-J2 x 1.5 mm2 round 93-50215014-J 93-60215014-J 93-70215044-J 93-80215044-J

Stranded conductors

Stranded conductors

Edition english 002 Product group 92-THL/93-AGL Page 7 of 13

Page 87: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individually PVC-extruded, not stranded

Individually PVC-extruded, stranded

PVC outer sheath

Jointly PVC-extruded

Copper wire braid

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.22 mm2 round 93-50202214-JCJ 93-60202214-JCJ 93-70202244-JCJ 93-80202244-JCJ2 x 0.5 mm2 round 93-50205014-JCJ 93-60205014-JCJ 93-70205044-JCJ 93-80205044-JCJ2 x 0.75 mm2 round 93-50207514-JCJ 93-60207514-JCJ 93-70207544-JCJ 93-80207544-JCJ2 x 1.5 mm2 round 93-50215014-JCJ 93-60215014-JCJ 93-70215044-JCJ 93-80215044-JCJ4 x 0.22 mm2 round 93-50402214-JCJ 93-60402214-JCJ 93-70402244-JCJ 93-80402244-JCJ4 x 0.5 mm2 round 93-50405014-JCJ 93-60405014-JCJ 93-70405044-JCJ 93-80405044-JCJ4 x 0.75 mm2 round 93-50407514-JCJ 93-60407514-JCJ 93-70407544-JCJ 93-80407544-JCJ4 x 1.5 mm2 round 93-50415014-JCJ 93-60415014-JCJ 93-70415044-JCJ 93-80415044-JCJ

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.22 mm2 round 93-10202214-JCJ 93-20202214-JCJ 93-30202214-JCJ 93-40202224-JCJ2 x 0.5 mm2 round 93-10205014-JCJ 93-20205014-JCJ 93-30205014-JCJ 93-40205024-JCJ2 x 0.75 mm2 round 93-10207514-JCJ 93-20207514-JCJ 93-30207514-JCJ 93-40207524-JCJ2 x 1.5 mm2 round 93-10215014-JCJ 93-20215014-JCJ 93-30215014-JCJ 93-40215024-JCJ4 x 0.22 mm2 round 93-10402214-JCJ 93-20402214-JCJ 93-30402214-JCJ 93-40402224-JCJ4 x 0.5 mm2 round 93-10405014-JCJ 93-20405014-JCJ 93-30405014-JCJ 93-40405024-JCJ4 x 0.75 mm2 round 93-10407514-JCJ 93-20407514-JCJ 93-30407514-JCJ 93-40407524-JCJ4 x 1.5 mm2 round 93-10415014-JCJ 93-20415014-JCJ 93-30415014-JCJ 93-40415024-JCJ

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 1.5 mm2 oval 93-50215011-JJ 93-60215011-JJ 93-70215041-JJ 93-80215041-JJ

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 1.5 mm2 oval 93-10215011-JJ 93-20215011-JJ 93-30215011-JJ 93-40215021-JJ

93 - AGL // Compensation cables

Compensation cablePVC - PVCJJ, oval

- Thermal stability of the insulation material-10°C to +105°C

- Use in a damp environment at a mediumdegree of mechanical stress

Compensation cablePVC – copper wire braid - PVCJCJ, round

- Thermal stability of the insulation material-10°C to +105°C

- Use in a damp environment at a mediumdegree of mechanical stress

- Shield against electromagnetic interference

Strandedconductors

Strandedconductors

Edition english 002 Product group 92-THL/93-AGL Page 8 of 13

Page 88: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individually PVC-extruded, stranded

Copper sheath cable

Plastic-lined aluminium shielding filmPVC outer sheath

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.22 mm2 round 93-50202214-JFJ 93-60202214-JFJ 93-70202244-JFJ 93-80202244-JFJ2 x 0.5 mm2 round 93-50205014-JFJ 93-60205014-JFJ 93-70205044-JFJ 93-80205044-JFJ2 x 0.75 mm2 round 93-50207514-JFJ 93-60207514-JFJ 93-70207544-JFJ 93-80207544-JFJ2 x 1.5 mm2 round 93-50215014-JFJ 93-60215014-JFJ 93-70215044-JFJ 93-80215044-JFJ4 x 0.22 mm2 round 93-50402214-JFJ 93-60402214-JFJ 93-70402244-JFJ 93-80402244-JFJ4 x 0.5 mm2 round 93-50405014-JFJ 93-60405014-JFJ 93-70405044-JFJ 93-80405044-JFJ4 x 0.75 mm2 round 93-50407514-JFJ 93-60407514-JFJ 93-70407544-JFJ 93-80407544-JFJ4 x 1.5 mm2 round 93-50415014-JFJ 93-60415014-JFJ 93-70415044-JFJ 93-80415044-JFJ

93 - AGL // Compensation cables

Compensation cablePVC – Aluminium foil,sheath cable - PVCJFJ, round

- Thermal stability of the insulation material-10°C to +105°C

- Use in a damp environment at a medium degreeof mechanical stress

- Extra shielding against electromagnetic interference, earth cable

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.22 mm2 round 93-10202214-JFJ 93-20202214-JFJ 93-30202214-JFJ 93-40202224-JFJ2 x 0.5 mm2 round 93-10205014-JFJ 93-20205014-JFJ 93-30205014-JFJ 93-40205024-JFJ2 x 0.75 mm2 round 93-10207514-JFJ 93-20207514-JFJ 93-30207514-JFJ 93-40207524-JFJ2 x 1.5 mm2 round 93-10215014-JFJ 93-20215014-JFJ 93-30215014-JFJ 93-40215024-JFJ4 x 0.22 mm2 round 93-10402214-JFJ 93-20402214-JFJ 93-30402214-JFJ 93-40402224-JFJ4 x 0.5 mm2 round 93-10405014-JFJ 93-20405014-JFJ 93-30405014-JFJ 93-40405024-JFJ4 x 0.75 mm2 round 93-10407514-JFJ 93-20407514-JFJ 93-30407514-JFJ 93-40407524-JFJ4 x 1.5 mm2 round 93-10415014-JFJ 93-20415014-JFJ 93-30415014-JFJ 93-40415024-JFJ

Edition english 002 Product group 92-THL/93-AGL Page 9 of 13

Page 89: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individual silicon-rubber extrusion, stranded

Jointly extruded with silicon-rubber

Individual silicon-rubber extrusion, not stranded

Jointly extruded with silicon-rubber

Stranded conductors

Stranded conductors

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 1.5 mm2 oval 93-50215011-SS 93-60215011-SS 93-70215041-SS 93-80215041-SS

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 1.5 mm2 oval 93-10215011-SS 93-20215011-SS 93-30215011-SS 93-40215021-SS

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.22 mm2 rund 93-50202214-SS 93-60202214-SS 93-70202244-SS 93-80202244-SS2 x 0.5 mm2 rund 93-50205014-SS 93-60205014-SS 93-70205044-SS 93-80205044-SS2 x 0.75 mm2 rund 93-50207514-SS 93-60207514-SS 93-70207544-SS 93-80207544-SS2 x 1.0 mm2 rund 93-50210014-SS 93-60210014-SS 93-70210044-SS 93-80210044-SS2 x 1.5 mm2 rund 93-50215014-SS 93-60215014-SS 93-70215044-SS 93-80215044-SS4 x 0.22 mm2 rund 93-50402214-SS 93-60402214-SS 93-70402244-SS 93-80402244-SS4 x 0.5 mm2 rund 93-50405014-SS 93-60405014-SS 93-70405044-SS 93-80405044-SS4 x 0.75 mm2 rund 93-50407514-SS 93-60407514-SS 93-70407544-SS 93-80407544-SS4 x 1.5 mm2 rund 93-50415014-SS 93-60415014-SS 93-70415044-SS 93-80415044-SS

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.22 mm2 rund 93-10202214-SS 93-20202214-SS 93-30202214-SS 93-40202224-SS2 x 0.5 mm2 rund 93-10205014-SS 93-20205014-SS 93-30205014-SS 93-40205024-SS2 x 0.75 mm2 rund 93-10207514-SS 93-20207514-SS 93-30207514-SS 93-40207524-SS2 x 1.0 mm2 rund 93-10210014-SS 93-20210014-SS 93-30210014-SS 93-40210024-SS2 x 1.5 mm2 rund 93-10215014-SS 93-20215014-SS 93-30215014-SS 93-40215024-SS4 x 0.22 mm2 rund 93-10402214-SS 93-20402214-SS 93-30402214-SS 93-40402224-SS4 x 0.5 mm2 rund 93-10405014-SS 93-20405014-SS 93-30405014-SS 93-40405024-SS4 x 0.75 mm2 rund 93-10407514-SS 93-20407514-SS 93-30407514-SS 93-40407524-SS4 x 1.5 mm2 rund 93-10415014-SS 93-20415014-SS 93-30415014-SS 93-40415024-SS

93 - AGL // Compensation cables

Compensation cableSilicon - SiliconSLSL, round

- Thermal stability of the insulation material-60°C to +180°C

- Use in a damp environment at a medium degreeof mechanical stress

Compensation cableSilicon - SiliconSLSL, oval

- Thermal stability of the insulation material-60°C to +180°C

- Use in a damp environment at a medium degreeof mechanical stress

Edition english 002 Product group 92-THL/93-AGL Page 10 of 13

Page 90: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individual silicon-rubber extrusion, stranded

Copper sheathcable

Plastic-lined aluminium shielding film

Silicon rubber-sheath

Individuallysilicon-extruded

Jointly braidedwith fibreglass

93 - AGL // Compensation cables

Compensation cableSilicon – Aluminium foil, sheath cable -SiliconSLFSL, round

- Thermal stability of the insulation material-60°C to +180°C

- Use in a damp environment at a medium degreeof mechanical stress

- Extra shielding against electromagnetic interference, earth cable

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.5 mm2 round 93-50205014-SFS 93-60205014-SFS 93-70205044-SFS 93-80205044-SFS2 x 0.75 mm2 round 93-50207514-SFS 93-60207514-SFS 93-70207544-SFS 93-80207544-SFS2 x 1.0 mm2 round 93-50210014-SFS 93-60210014-SFS 93-70210044-SFS 93-80210044-SFS2 x 1.5 mm2 round 93-50215014-SFS 93-60215014-SFS 93-70215044-SFS 93-80215044-SFS4 x 0.75 mm2 round 93-50407514-SFS 93-60407514-SFS 93-70407544-SFS 93-80407544-SFS

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.5 mm2 round 93-10205014-SFS 93-20205014-SFS 93-30205014-SFS 93-40205024-SFS2 x 0.75 mm2 round 93-10207514-SFS 93-20207514-SFS 93-30207514-SFS 93-40207524-SFS2 x 1.0 mm2 round 93-10210014-SFS 93-20210014-SFS 93-30210014-SFS 93-40210024-SFS2 x 1.5 mm2 round 93-10215014-SFS 93-20215014-SFS 93-30215014-SFS 93-40215024-SFS4 x 0.75 mm2 round 93-10407514-SFS 93-20407514-SFS 93-30407514-SFS 93-40407524-SFS

Compensation cableSilicon - FibreglassSG, oval and round models, stranded

- Thermal stability of the insulation materialup to 180°C

- Use in a damp environment at a low degreeof mechanical stress

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 1.5 mm2 oval 93-50215011-SG 93-60215011-SG 93-70215041-SG 93-80215041-SG4 x 1.5 mm2 round 93-50415011-SG 93-60415011-SG 93-70415041-SG 93-80415041-SG

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 1.5 mm2 oval 93-10215011-SG 93-20215011-SG 93-30215011-SG 93-40215021-SG4 x 1.5 mm2 round 93-10415011-SG 93-20415011-SG 93-30415011-SG 93-40415021-SG

Edition english 002 Product group 92-THL/93-AGL Page 11 of 13

Page 91: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individuallysilicon-extruded

Wire braid, galvanised steelwith a marker thread

Jointly covered with fibreglass

Individuallysilicon-extruded

Cable braid, galvanised steelwith a marker thread

Jointly silicon-extruded

93 - AGL // Compensation cables

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.75 mm2 oval 93-10207511-SGP 93-20207511-SGP 93-30207511-SGP 93-40207521-SGP2 x 1.5 mm2 oval 93-10215011-SGP 93-20215011-SGP 93-30215011-SGP 93-40215021-SGP4 x 0.5 mm2 round 93-10405014-SGP 93-20405014-SGP 93-30405014-SGP 93-40405024-SGP4 x 1.5 mm2 round 93-10415014-SGP 93-20415014-SGP 93-30415014-SGP 93-40415024-SGP

Compensation cableSilicon – Fibreglass – Cable braidSGP, oval and round models, stranded

- Thermal stability of the insulation materialup to 180°C

- Use in a damp environment at highmechanical stress

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.75 mm2 oval 93-50207511-SGP 93-60207511-SGP 93-70207541-SGP 93-80207541-SGP2 x 1.5 mm2 oval 93-50215011-SGP 93-60215011-SGP 93-70215041-SGP 93-80215041-SGP4 x 0.5 mm2 round 93-50405014-SGP 93-60405014-SGP 93-70405044-SGP 93-80405044-SGP4 x 1.5 mm2 round 93-50415014-SGP 93-60415014-SGP 93-70415044-SGP 93-80415044-SGP

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.75 mm2 oval 93-10207511-SSP 93-20207511-SSP 93-30207511-SSP 93-40207521-SSP2 x 1.5 mm2 oval 93-10215011-SSP 93-20215011-SSP 93-30215011-SSP 93-40215021-SSP4 x 0.5 mm2 round 93-10405014-SSP 93-20405014-SSP 93-30405014-SSP 93-40405024-SSP4 x 1.5 mm2 round 93-10415014-SSP 93-20415014-SSP 93-30415014-SSP 93-40415024-SSP

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.75 mm2 oval 93-50207511-SSP 93-60207511-SSP 93-70207541-SSP 93-80207541-SSP2 x 1.5 mm2 oval 93-50215011-SSP 93-60215011-SSP 93-70215041-SSP 93-80215041-SSP4 x 0.5 mm2 round 93-50405014-SSP 93-60405014-SSP 93-70405044-SSP 93-80405044-SSP4 x 1.5 mm2 round 93-50415014-SSP 93-60415014-SSP 93-70415044-SSP 93-80415044-SSP

Compensation cableSilicon – Silicon – Cable braidSSP, oval and round models, stranded

- Thermal stability of the insulation materialup to 180°C

- Use in a damp environment at highmechanical stress

Edition english 002 Product group 92-THL/93-AGL Page 12 of 13

Page 92: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Individually FEP-extruded, stranded

Jointly FEP-extruded

Individually FEP-extruded, stranded

Copper sheath cable

Plastic-lined aluminium shielding filmFEP outer sheath

93 - AGL // Compensation cables

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.5 mm2 round 93-50205014-EE 93-60205014-EE 93-70205044-EE 93-80205044-EE2 x 0.75 mm2 round 93-50207514-EE 93-60207514-EE 93-70207544-EE 93-80207544-EE2 x 1.0 mm2 round 93-50210014-EE 93-60210014-EE 93-70210044-EE 93-80210044-EE

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.5 mm2 round 93-10205014-EE 93-20205014-EE 93-30205014-EE 93-40205024-EE2 x 0.75 mm2 round 93-10207514-EE 93-20207514-EE 93-30207514-EE 93-40207524-EE2 x 1.0 mm2 round 93-10210014-EE 93-20210014-EE 93-30210014-EE 93-40210024-EE

Compensation cableTeflon FEP - Teflon FEPEE, round

- Thermal stability of the insulation material-200°C to +205°C

- Use in a damp environment at high temperaturesand for special requirements concerning resistanceto chemicals

Compensation cableTeflon FEP – Aluminium foil,Sheath cable - Teflon FEPEFE, round

- Thermal stability of the insulation material-200°C to +205°C

- Use in a damp environment at high temperaturesspecial requirements concerning resistance to chemicals

- Extra shielding against electromagnetic interference, earth cable

Cable Shape Fe-CuNi/J Nicrosil-Nisil/N Wo3Re-Wo25Re/D Wo5Re-Wo26Re/C+ black - white IEC 584/3 + pink - white IEC 584/3 + red - white + red - white

2 x 0.5 mm2 round 93-50205014-EFE 93-60205014-EFE 93-70205044-EFE 93-80205044-EFE2 x 0.75 mm2 round 93-50207514-EFE 93-60207514-EFE 93-70207544-EFE 93-80207544-EFE2 x 1.0 mm2 round 93-50210014-EFE 93-60210014-EFE 93-70210044-EFE 93-80210044-EFE

Cable Shape PtRh-Pt/S R Pt30Rh-Pt6Rh/B NiCr-Ni/K Fe-CuNi/L+ orange - white IEC 584/3 + grey - white IEC 584/3 + green - white IEC 584/3 + red - blue DIN 43710

2 x 0.5 mm2 round 93-10205014-EFE 93-20205014-EFE 93-30205014-EFE 93-40205024-EFE2 x 0.75 mm2 round 93-10207514-EFE 93-20207514-EFE 93-30207514-EFE 93-40207524-EFE2 x 1.0 mm2 round 93-10210014-EFE 93-20210014-EFE 93-30210014-EFE 93-40210024-EFE

Edition english 002 Product group 92-THL/93-AGL Page 13 of 13

Page 93: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

99-EZT

99 - EZT // Individual components

Messtechnik Schaffhausen GmbHMühlenstrasse 4, CH-8260 Stein am RheinTelefon +41 52-672 50 00Telefax +41 52-672 50 01www.mts.ch, e-mail: [email protected]

Messen Prüfen Automatisieren www.mts.ch

MTS

Page 94: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �Product group 99-EZT

Connection heads Type A, AUZ, AUS and AUZH

Head Type ALarge, slanted head with a fitted removable cover (screwed)

Connection (Xa) forthe thermowell Protective Cable Approx. or the holding tube system outlet weight/g Article number

Thread M24 x 1.5 IP 54 M20 x 1.5 250 98-91300106-GM24Hole 11.8 mm IP 53 M20 x 1.5 260 On requestHole 22.8 mm IP 53 M20 x 1.5 255 98-91300106-G022Hole 24.8 mm IP 53 M20 x 1.5 250 98-91300106-G024Hole 26.8 mm IP 53 M20 x 1.5 235 98-91300106-G026Hole 28.8 mm IP 53 M20 x 1.5 235 98-91300106-G028Hole 32.8 mm IP 53 M20 x 1.5 235 98-91300106-G032

Connection head made of die-cast light alloy for the protection and holding tubesof various dimensions.

Head Type AUZSpherical head with a hinged cover and a cheese-head screw

Connection (Xa) forthe thermowell Protective Cable Approx. or the holding tube system outlet weight/g Article number

Thread M24 x 1.5 IP 65 M20 x 1.5 260 99-91300306-GM24Hole 22.8 mm IP 54 M20 x 1.5 280 99-91300306-G022Hole 24.8 mm IP 54 M20 x 1.5 270 99-91300306-G024Hole 32.8 mm IP 54 M20 x 1.5 260 99-91300306-G032G 3/8 I IP 65 M20 x 1.5 280 On requestG 1/2 I IP 65 M20 x 1.5 270 On request

Connection head made of die-cast light alloy with a hinged cover and a cheese-head screw for protection and holding tubes of various dimensions.

Head Type AUSSpherical head with a hinged cover and a snap fastener

Connection (Xa) forthe thermowell Protective Cable Approx. or the holding tube system outlet weight/g Article number

Thread M24 x 1.5 IP 65 M20 x 1.5 260 99-91300206-GM24Hole 22.8 mm IP 54 M20 x 1.5 280 99-91300206-G022Hole 24.8 mm IP 54 M20 x 1.5 270 99-91300206-G024Hole 32.8 mm IP 54 M20 x 1.5 260 99-91300206-G032G 3/8 I IP 65 M20 x 1.5 280 On requestG 1/2 I IP 65 M20 x 1.5 270 On request

Connection head made of die-cast light alloy with a hinged cover and a snap fastening for protection and holding tubes of various dimensions.

Head Type AUZHRaised hinged cover with a cheese-head screw (AUSH alternative)

Connection (Xa) forthe thermowell Protective Cable Approx. or the holding tube system outlet weight/g Article number

Hole 15.8 mm IP 54 M20 x 1.5 320 99-91300506-G015Hole 22.8 mm IP 54 M20 x 1.5 320 99-91300506-G022Hole 32.8 mm IP 54 M20 x 1.5 320 99-91300506-G032Thread M24 x 1.5 IP 65 M20 x 1.5 320 99-91300506-GM24Thread M22 x 1.5 IP 65 M20 x 1.5 320 99-91300506-GM22

Connection head made of die-cast light alloy with a hinged cover for protection and holding tubes of various dimensions.This connection head is suitable for the installation of a head transmitter in the cover.

94

63.5

XA

100

74

XA

100

74

XA

56.5

XA

125

Page 95: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page 2Product group 99-EZT

Connection heads Type B, B-h, BUZ, BUS and BUZH

Head Type BSmall, slanted head with a fitted removable cover (screwed)

Connection (Xa) forthe thermowell Protective Cable Approx. or the holding tube system outlet weight/g Article number

Hole 10.8 mm IP 53 M20 x 1.5 195 98-91300706-G010Hole 15.8 mm IP 53 M20 x 1.5 195 98-91300706-G015Thread M24 x 1.5 IP 53 M20 x 1.5 190 98-91300706-GM24G 1/2 I IP 53 M20 x 1.5 190 On request

Connection head made of die-cast light alloy for the protection and holding tubes of various dimensions.

Head Type B-h (high)Small, slanted head with a fitted removable cover (screwed)

Connection (Xa) forthe thermowell Protective Cable Approx. or the holding tube system outlet weight/g Article number

Hole 10.8 mm IP 53 M20 x 1.5 160 98-91301206-G010Hole 15.8 mm IP 53 M20 x 1.5 160 98-91301206-G015Thread M24 x 1.5 IP 53 M20 x 1.5 160 98-91301206-GM24G 1/2 I IP 53 M20 x 1.5 160 On request

Connection head made of die-cast light alloy for the protection and holding tubes of various dimensions (generally used for right-angle thermocouples).

Head Type BUZSpherical head with a hinged cover and a cheese-head screw

Connection (Xa) forthe thermowell Protective Cable Approx. or the holding tube system outlet weight/g Article number

Hole 15.3 mm IP 54 M20 x 1.5 220 99-91300906-G015Hole 22.5 mm IP 54 M20 x 1.5 210 99-91300906-G022Thread M24 x 1.5 IP 65 M20 x 1.5 210 99-91300906-GM24G 1/2 I IP 65 M20 x 1.5 215 99-91300906-GG12

Connection head made of die-cast light alloy with a hinged cover for protection and holding tubes of various dimensions.

Head Type BUSSpherical head with a hinged cover and a snap fastening

Head Type BUZHRaised hinged cover with a cheese-head screw (BUSH alternative)

Connection (Xa) forthe thermowell Protective Cable Approx. or the holding tube system outlet weight/g Article number

Hole 15.8 mm IP 54 M20 x 1.5 275 99-91301106-G015Hole 22.8 mm IP 54 M20 x 1.5 270 99-91301106-G022Thread M24 x 1.5 IP 65 M20 x 1.5 270 99-91301106-GM24G 1/2 I IP 65 M20 x 1.5 275 99-91301106-GG12

Connection head made of die-cast light alloy with a hinged cover for protection and holding tubes of various dimensions.This connection head is suitable for the installation of a head transmitter in the cover.

Connection (Xa) forthe thermowell Protective Cable Approx. or the holding tube system outlet weight/g Article number

Hole 15.3 mm IP 54 M20 x 1.5 220 99-91300806-G015Hole 22.5 mm IP 54 M20 x 1.5 210 99-91300806-G022Thread M24 x 1.5 IP 65 M20 x 1.5 210 99-91300806-GM24G 1/2 I IP 65 M20 x 1.5 215 99-91300806-GG12

Connection head made of die-cast light alloy with a hinged cover for protection and holding tubes of various dimensions.

75

50

XA

80

45

XA

85

42

XA

85

42

XA

110

42

XA

Page 96: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �

Connection heads Type L, NA, DL and E

Product group 99-EZT

Connection head Type L Cylindrical head with a slip lid

Material: Lower part made of nickel-plated brass, cover made of aluminiumConnection: Bracket clamp d = 8.2 mm *Cable entry: PG 7 Weight: approx. 80 gGünther Art. no. 99-91301503-0008

* The bracket clamp serves to clamp the thermowell (ceramic, metal or quartz glass)

Connection head Type NA Small spherical head with a hinged cover

Connection head Type DL Small spherical head with a screw cover

Material: Die-cast light alloy Die-cast light alloyConnection: Ø 15.8 mm M24 x 1.5 threadCable entry: M20 x 1.5 / M22 x 1.5 mm M20 x 1.5 mmWeight: approx. 165 g approx. 160 g Günther Art no. 99-91301606-G015 99-91301606-GM24 99-91301607-G015

Material: Die-cast light alloy Die-cast light alloy Die-cast light alloyConnection: Female thread Male thread Ø 6.1 mm M10 x 1 M20 x 0.75 Cable entry: PG 9 PG 9 PG 9Weight: approx. 70 g approx. 70 g approx. 70 gProtection: IP 54 IP 54 IP 54 Günther Art. no. 99-91301702-GM10 99-91301702-GM20 99-91301702-G006

The connection heads shown above are the most widely-used models. Other models are available on request.

50

29

XA

Ø 48

14

72

39

XA

53

18

Ø 24

~ 39

PG 7

Page 97: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �

Connection sockets for connection heads, Type A and B

Product group 99-EZT

Socket A, standardFor base thermocouples from Ø 1.38 mm to Ø 3.0 mmArt. no. 98-91540000-0002

Socket A, double For base thermocouplesfrom Ø 1.38 mm to Ø 3.0 mmArt. no. 98-91540000-0004

Accessories: 1 washer 55 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

Accessories: 1 washer 55 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

Socket A, tripleFor base thermocouples up to Ø 1.6 mmArt. no. 98-91540002-0006

Accessories: 1 washer 55 mm 2 fastening screws (M4 x 20 mm with a washer 10 x4.5 mm)

Socket A, standard With a test socket for base thermocouplesArt. no. 98-91540003-0002

Accessories: 1 washer 55 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

Socket A, double With a test socket for base thermocouplesArt. no. 98-91540003-0004

Accessories: 1 washer 55 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

Round socket, Type B, standardfor sheath thermocouples Art. no. 99-91550000-0002

Accessories: 1 washer 55 mm made of VA steel (2 mm thick) 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

Round socket, Type B, double for sheath thermocouplesArt. no. 99-91550000-0004

Accessories: 1 washer 55 mm made of VA steel (2 mm thick) 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

55

46

16

12 55

46

16

12

58 46

55

46

55

46

10

46

~ 38 ~ 38

46

10

Page 98: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �

Connection sockets for connecton heads, Type A and B

Product group 99-EZT

Socket A, standardFor precious metal thermocouplesArt. no. 98-91540001-0002

Socket A, double For precious metal thermocouples Art. no. 98-91540001-0004

Accessories: 1 washer 55 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm) 1 retaining spring

Accessories: 1 washer 55 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm) 1 retaining spring

Socket A, tripleFor precious metal thermocouples Art. no. 98-91540002-0006

Accessories: 1 washer 55 mm 2 fastening screws (M4 x 20 mm with a washer 10 x 4.5 mm) 1 retaining spring

Socket B, standardFor base thermocouples from Ø 0.5 mm to Ø 2.0mmArt. no. 98-91550000-0002

Accessories: 1 washer 42 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

Socket B, doubleFor base thermocouples from Ø 0.5 mm to Ø 2.0 mmArt. no. 98-91550000-0004

Accessories: 1 washer 42 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

Socket B, double For precious metal thermocouples

Art. no. 98-91550001-0004

Accessories: 1 washer 42 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

Socket B, standard(2 sheath clamps)

Art. no. 98-91550010-0002

Accessories: 1 washer 40 mm 2 fastening screws M4 x 16 mm, each with 1 washer 7 x 4.2 mm

Socket B, standardFor precious metal thermocouples Art. no. 98-91550001-0002

Accessories: 1 washer 42 mm 2 fastening screws (M4 x 18 mm with a washer 10 x 4.5 mm)

Socket B, double(4 sheath clamps)

Art. no. 98-91550010-0004

Accessories: 1 washer 40 mm 2 fastening screws M4 x 16 mm, each with 1 washer 7 x 4.2 mm

46

55

10

46

55

10

4656

33

40

33

40

33

40

33

40

Page 99: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �

Plug-and-socket connectors (plugs, couplers and assembly elements) “Standard” model

Product group 99-EZT

Standard plugs

Standard couplers

Application:Plug-and-socket connectors for the measuring circuits of thermocouples and resistance thermometers. Solid pins ensure a reliable connection.

Mechanical structure:– Casing made of plastic filled with fibre glass– Pins and sleeves thermally stress-relieved– Solid pins and spring-loaded sockets– Reverse voltage protection through various pin thicknesses– Central cover fastening facilitates assembly– Internally separated conductors prevent short circuits– Terminal screws enable fast connections

Conductor cross-section:– Secure clamping from Ø 0.2 mm to Ø 2.0 mm– Max. cable diameter of 8.0 mm

Thermal load:– Max. 200°C

Code colours for the casing:– All of the international colour codes are available: DIN IEC, DIN 43710, ANSI, NFE, BS, JIS, etc.

Accessories:– Strain reliefs, gaskets, splash protection, etc.

Type J/L K S B NContact + Fe NiCr Cu Cu NicrosilContact - CuNi Ni Alloy#11 Cu Nisil

DIN IEC 584 colour coding

Casing colour Black (type J) Green Orange Grey PinkPlug 99-91440010-HJ00 99-91440010-HK00 99-91440010-HS00 99-91440010-HB00 99-91440010-HN00Coupler 99-91441010-HJ00 99-91441010-HK00 99-91441010-HS00 99-91441010-HB00 99-91441010-HN00

DIN 43710 colour coding

Casing colour Blue (type L) Green - White -Plug 99-91440020-HL00 99-91440020-HK00 - On request -Coupler 99-91441020-HL00 99-91442020-HK00 - On request -

ANSI colour coding

Casing colour Black Yellow Green White OrangePlug On request 99-91440030-HK00 99-91440030-HS00 On request On request Coupler On request 99-91441030-HK00 99-91441030-HS00 On request On request

The strain relief (accessories) fixes cables of varying diameters onto the plugs and the couplers. Strain relief Art. no. 99-91444000-0000Assembly is carried out by means of screwing it into the female thread in the plug-and-socket connector.

Page 100: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �

Type K S BContact + NiCr Cu Cu Contact - Ni Alloy#11 Cu

Plug 99-91480010-HK00 99-91480010-HS00 99-91480010-HB00Coupler 99-91481010-HK00 99-91481010-HS00 99-91481010-HB00

Standard ceramic plugs/couplers

Plug-and-socket connectors (plugs, couplers and assembly elements) “Standard” model

Product group 99-EZT

Standard high-temperature plugs

Standard high-temperature couplers

Application:Plug-and-socket connectors for the measuring circuits of thermocouples and resistance thermometers. Solid pins ensure a reliable connection.

Mechanical structure:– Casing made of temperature-resistant special plastic for high ambient temperatures– Pins and sleeves thermally stress-relieved– Solid pins and spring-loaded sockets– Reverse voltage protection through various pin thicknesses– Central cover fastening facilitates assembly– Internally separated conductors prevent short circuits– Terminal screws enable fast connections

Conductor cross-section:– Secure clamping from Ø 0.2 mm to Ø 2.0 mm– Max. cable diameter of 8.0 mm

Thermal load:– Max. 350°C

Colour coding:– Casing brown, with element code

Type J/L K S B NContact + Fe NiCr Cu Cu NicrosilContact - CuNi Ni Alloy#11 Cu Nisil

Plug On request 99-91460010-HK00 99-91460010-HS00 99-91460010-HB00 99-91460010-HN00Coupler On request 99-91461010-HK00 99-91461010-HS00 99-91461010-HB00 99-91461010-HN00

Application:Plug-and-socket connectors for the measuring circuits of thermal elements and resistance thermometers. Solid pins ensure a reliable connection.

Mechanical structure:– Ceramic casing for extremely high ambient temperatures– Pins and sleeves thermally stress-relieved– Solid pins and spring-loaded sockets– Reverse voltage protection through various pin thicknesses– Central cover fastening facilitates assembly– Internally separated conductors prevent short circuits– Terminal screws enable fast connections

Conductor cross-section:– Secure clamping from Ø 0.2 mm to Ø 2.0 mm– Max. cable diameter of 8.0 mm

Thermal load:– Max. 650°C

Colour coding:– Casing white, with element code

Page 101: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �

Plug-and-socket connectors (plugs and couplers)“Miniature” model

Product group 99-EZT

Miniature plugs

Miniature couplers

Application:Plug-and-socket connectors for the measuring circuits of thermocouples and resistance thermometers. Solid pins ensure a reliable connection.

Mechanical structure:– Casing made of plastic filled with fibre glass– Pins and sleeves thermally stress-relieved– Solid pins and spring-loaded sockets– Reverse voltage protection through various pin widths– Central cover fastening facilitates assembly– Internally separated conductors prevent short circuits– Terminal screws enable fast connections

Conductor cross-section:– Secure clamping from Ø 0.1 mm to Ø 0.6 mm– Max. cable diameter of 4.5 mm

Thermal load:– Max. 200°C

Code colours for the casing:– All of the international colour codes are available: DIN IEC, DIN 43710, ANSI, NFE, BS, JIS, etc.

Accessories:– Strain reliefs, gaskets, splash protection, etc.

Type J/L K S B NContact + Fe NiCr Cu Cu NicrosilContact - CuNi Ni Alloy#11 Cu Nisil

DIN IEC 584 colour coding

Casing colour Black (type J) Green Orange Grey PinkPlug 99-91450010-HJ00 99-91450010-HK00 99-91450010-HS00 99-91450010-HB00 99-91450010-HN00Coupler 99-91451010-HJ00 99-91451010-HK00 99-91451010-HS00 99-91451010-HB00 99-91451010-HN00

DIN 43710 colour coding

Casing colour Blue (type L) Green - White -Plug 99-91450020-HL00 99-91450020-HK00 - On request -Coupler 99-91451020-HL00 99-91451020-HK00 - On request -

ANSI colour coding

Casing colour Black Yellow Green White OrangePlug On request 99-91450030-HK00 99-91450030-HS00 On request On requestCoupler On request 99-91451030-HK00 99-91451030-HS00 On request On request

Page 102: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �

Miniature ceramic plugs/couplers

Plug-and-socket connectors (plugs and couplers)“Miniature” model

Product group 99-EZT

Miniature high-temperature plugs

Miniature high-temperature couplers

Application:Plug-and-socket connectors for the measuring circuits of thermocouples and resistance thermometers. Solid pins ensure a reliable connection.

Mechanical structure:– Casing made of temperature-resistant special plastic for high ambient temperatures– Pins and sleeves thermally stress-relieved– Solid pins and spring-loaded sockets– Reverse voltage protection through various pin widths– Central cover fastening facilitates assembly– Internally separated conductors prevent short circuits– Terminal screws enable fast connections

Conductor cross-section:– Secure clamping from Ø 0.1 mm to Ø 0.6 mm– Max. cable diameter of 4.5 mm

Thermal load:– Max. 350°C

Colour coding:– Casing brown, with element code

Type J/L K S B NContact + Fe NiCr Cu Cu NicrosilContact - CuNi Ni Alloy#11 Cu Nisil

Plug On request 99-91470010-HK00 99-91470010-HS00 99-91470010-HB00 99-91470010-HN00Coupler On request 99-91471010-HK00 99-91471010-HS00 99-91471010-HB00 99-91471010-HN00

Application:Plug-and-socket connectors for the measuring circuits of thermocouples and resistance thermometers. Solid pins ensure a reliable connection.

Mechanical structure:– Ceramic casing for extremely high ambient temperatures– Pins and sleeves thermally stress-relieved– Solid pins and spring-loaded sockets– Reverse voltage protection through various pin widths– Central cover fastening facilitates assembly– Internally separated conductors prevent short circuits– Terminal screws enable fast connections

Conductor cross-section:– Secure clamping from Ø 0.1 mm to Ø 0.5 mm– Max. cable diameter of 3.6 mm

Thermal load:– Max. 650°C

Colour coding:– Casing white, with element code

Type J/L K SContact + Fe NiCr CuContact - CuNi Ni Alloy#11

Plug On request 99-91490010-HK00 99-91490010-HS00Coupler On request 99-91491010-HK00 99-91491010-HS00

Page 103: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �0

Plug-and-sockets (panels)“Standard” model

Product group 99-EZT

Standard panels – horizontal Standard panels - vertical

Mechanical structure: – Aluminium front panel, anodised, protected against corrosion.– Measuring circuits numbered, abrasion-resistant, smudge-proof– Fastenings made of stainless steel and nickel-plated brass– Assembly and construction design prevent the assembled built-in couplers from being pushed in or pressed out.– Slanted connection planes enable access for the wires to be connected and disconnected while installed.– Only a few screws need to be removed in order to replace individual built-in couplers– Standard panels for 1 to 6 measuring circuits

Application:For permanent installation on control panels and casings of any kind for inserting standard plugs.

Conductor cross-section:– Secure clamping from Ø 0.2 mm to Ø 2.0 mm

Thermal load:– Max. 200°C

Horizontal model

Type Dimensions S to IEC B to IEC N to IECColour [mm] “orange” “grey” “violet” 1 measuring circuit 38 x 38 98-91442111-HS01 98-91442111-HB01 98-91442111-HN01 6 measuring circuits 146 x 67 98-91442111-HS06 98-91442111-HB06 98-91442111-HN0612 measuring circuits 260 x 67 98-91442111-HS12 98-91442111-HB12 98-91442111-HN1224 measuring circuits 260 x 115 98-91442111-HS24 98-91442111-HB24 98-91442111-HN24

Horizontal model

Type Dimensions J to IEC L to DIN K to IEC Colour [mm] “black” “blue” “green” 1 measuring circuit 38 x 38 98-91442111-HJ01 98-91442121-HL01 98-91442111-HK01 6 measuring circuits 146 x 67 98-91442111-HJ06 98-91442121-HL06 98-91442111-HK0612 measuring circuits 260 x 67 98-91442111-HJ12 98-91442121-HL12 98-91442111-HK1224 measuring circuits 260 x 115 98-91442111-HJ24 98-91442121-HL24 98-91442111-HK24

Vertical model

Type Dimensions J to IEC L to DIN K to IEC Colour [mm] “black” “blue” “green” 6 measuring circuits 72 x 116 98-91442211-HJ06 98-91442221-HL06 98-91442211-HK06

Vertical model

Type Dimensions S to IEC B to IEC N to IECColour [mm] “orange” “grey” “violet” 6 measuring circuits 72 x 116 98-91442211-HS06 98-91442211-HB06 98-91442211-HN06

Page 104: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page ��

Standard miniature panel jacks – rectangular and round:

Plug-and-sockets (panels)“Miniature” model

Product group 99-EZT

Miniature panels – horizontal:

Application:For permanent installation on control panels and casings of any kind for inserting miniature plugs.

Conductor cross-section:– Secure clamping from Ø 0.1 mm to Ø 0.6 mm

Thermal load:– Max. 200°C

Mechanical structure:– Aluminium front panel, anodised, protected against corrosion– Measuring circuits numbered, abrasion-resistant, smudge-proof– Fastenings made of stainless steel and nickel-plated brass– Assembly and construction design prevent the assembled built-in couplers from being pushed in or pressed out.– Slanted connection planes enable access for the wires to be connected and disconnected while installed.– Only a few screws need to be removed in order to replace individual built-in couplers– Standard panels for 1 to 6 measuring circuits

Application:For permanent installation on control panels and casings of any kind for inserting miniature plugs.

Conductor cross-section:– Secure clamping from Ø 0.1 mm to Ø 0.6 mm

Thermal load:– Max. 200°C

Type J to IEC L to DIN K to IEC Colour “black” “blue” “green” Rectangular 98-91456011-HJ00 98-91456021-HL00 98-91456011-HK00 Round 98-91456012-HJ00 98-91456022-HL00 98-91456012-HK00

Type S to IEC B to IEC N to IECColour “orange” “grey” “violet”Rectangular 98-91456011-HS00 98-91456011-HB00 98-91456011-HN00Round 98-91456012-HS00 98-91456012-HB00 98-91456012-HN00

Type Dimensions J to IEC L to DIN K to IEC

Colour “black” “blue” “green” 1 measuring circuit 38 x 38 98-91452111-HJ01 98-91452121-HL01 98-91452111-HK01 6 measuring circuits 113 x 38 98-91452111-HJ06 98-91452121-HL06 98-91452111-HK06 12 measuring circuits 203 x 38 98-91452111-HJ12 98-91452121-HL12 98-91452111-HK12 24 measuring circuits 203 x 76 98-91452111-HJ24 98-91452121-HL24 98-91452111-HK24

Type Dimensions S to IEC B to IEC N to IEC

Colour “orange” “grey” “violet” 1 measuring circuit 38 x 38 98-91452111-HS01 98-91452111-HB01 98-91452111-HN01 6 measuring circuits 113 x 38 98-91452111-HS06 98-91452111-HB06 98-91452111-HN0612 measuring circuits 203 x 38 98-91452111-HS12 98-91452111-HB12 98-91452111-HN1224 measuring circuits 203 x 76 98-91452111-HS24 98-91452111-HB24 98-91452111-HN24

Page 105: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page �2

Lemo plugs and couplers for connection to sheath thermo-couples, resistance thermometers and supply lines

Case: Chromium-plated brassContacts: Gold-plated brassInsulation: PEEKMax. temperature: 250°C

No. of poles Collet Article number 2 5.2 mm - cable collet 98-91422302-0052 2 5.2 mm - cable collet 98-91422302-0072 2 3.1 mm - thermal collet 98-91422322-0031 2 4.6 mm - thermal collet 98-91422322-0046 2 6.1 mm - thermal collet 98-91422322-0061 4 5.2 mm - cable collet 98-91422304-0042 4 7.2 mm - cable collet 98-91422304-0047 4 3.1 mm - thermal collet 98-91422324-0031 4 4.6 mm - thermal collet 98-91422324-0046 4 6.1 mm - thermal collet 98-91422324-0061

Lemo coupler Size 2, L=50,0 mm D=14,8 mm C=8,5 mm

Lemo coupler Size 1, L=40,5 mm D=11,0 mm C=6,2 mm

No. of poles Collet Article number 2 3.7 mm - cable collet 98-91421302-0037 2 4.7 mm - cable collet 98-91421302-0047 2 1.6 mm - thermal collet 98-91421322-0016 2 2.2 mm - thermal collet 98-91421322-0022 2 3.1 mm - thermal collet 98-91421322-0031 2 4.6 mm - thermal collet 98-91421322-0046 2 6.1 mm - thermal collet 98-91421322-0061 4 3.7 mm - cable collet 98-91421304-0037 4 4.7 mm - cable collet 98-91421304-0047 4 1.6 mm - thermal collet 98-91421324-0016 4 2.2 mm - thermal collet 98-91421324-0022 4 3.1 mm - thermal collet 98-91421324-0031 4 4.6 mm - thermal collet 98-91421324-0046 4 6.1 mm - thermal collet 98-91421324-0061

No. of poles Collet Article number 2 4.2 mm - cable collet 98-91420202-0042

2 4.7 mm - cable collet 98-91420202-0047 2 1.6 mm - thermal collet 98-91420222-0016 2 2.1 mm - thermal collet 98-91420222-0021 2 3.0 mm - thermal collet 98-91420222-0030 4 4.2 mm - cable collet 98-91420204-0042 4 4.7 mm - cable collet 98-91420204-0047 4 1.6 mm - thermal collet 98-91420224-0016 4 2.1 mm - thermal collet 98-91420224-0021 4 3.0 mm - thermal collet 98-91420224-0030

Lemo plug Size 0, L=34.5 mm D=9.0 mm C=4.2 mm

Plug-and-socket connectors (type Lemo)

Product group 99-EZT

Plug, Lemo*) Coupling, Lemo*)

*) Lemo plug-and-socket connections Size 3 and panel jacks Sizes 1 and 2 available on request.

No. of poles Collet Article number 2 5.2 mm - cable collet 98-91422202-0052 2 7.2 mm - cable collet 98-91422202-0072 2 3.1 mm - thermal collet 98-91422222-0031 2 4.6 mm - thermal collet 98-91422222-0046 2 6.1 mm - thermal collet 98-91422222-0061 4 5.2 mm - cable collet 98-91422204-0042 4 7.2 mm - cable collet 98-91422204-0047 4 3.1 mm - thermal collet 98-91422224-0031 4 4.6 mm - thermal collet 98-91422224-0046 4 6.1 mm - thermal collet 98-91422224-0061

Lemo plug Size 2, L=52,0 mm D=14,8 mm C=8,5 mm

Lemo plug Size 1, L=42,5 mm D=12,0 mm C=6,2 mm

No. of poles Collet Article number 2 3.7 mm - cable collet 98-91421202-0037 2 4.7 mm - cable collet 98-91421202-0047 2 1.6 mm - thermal collet 98-91421222-0016 2 2.2 mm - thermal collet 98-91421222-0022 2 3.1 mm - thermal collet 98-91421222-0031 2 4.6 mm - thermal collet 98-91421222-0046 2 6.1 mm - thermal collet 98-91421222-0061 4 3.7 mm - cable collet 98-91421204-0037 4 4.7 mm - cable collet 98-91421204-0047 4 1.6 mm - thermal collet 98-91421224-0016 4 2.2 mm - thermal collet 98-91421224-0022 4 3.1 mm - thermal collet 98-91421224-0031 4 4.6 mm - thermal collet 98-91421224-0046 4 6.1 mm - thermal collet 98-91421224-0061

Lemo coupler Size 0, L=33,5 mm D=8,9 mm C=4,2 mm

No. of poles Collet Article number 2 4.2 mm - cable collet 98-91420302-0042 2 4.7 mm - cable collet 98-91420302-0047 2 1.6 mm - thermal collet 98-91420322-0016 2 2.1 mm - thermal collet 98-91420322-0021 2 3.0 mm - thermal collet 98-91420322-0030 4 4.2 mm - cable collet 98-91420304-0042 4 4.7 mm - cable collet 98-91420304-0047 4 1.6 mm - thermal collet 98-91420324-0016 4 2.1 mm - thermal collet 98-91420324-0021 4 3.0 mm - thermal collet 98-91420324-0030

L

C D

L

C D

Page 106: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page ��

Ceramic tubes and insulation rods for thermocouples

Product group 99-EZT

Models:Open on both ends, closed on one end, open on both ends with a flange, closed on one end with a flange. We supply thermocouple thermowells, insulation rods and short insulation tubes for thermocouples made of the materials ALSINT 99.7 = TYPE C 799, PYTHAGORAS = TYPE C 610 and SILLIMANTIN 60 = TYPE C 530Tolerances in accordance with DIN 40 680 are maintained. Tighter tolerances on request.

Properties Dim. Alsint 99.7 Pythagoras Sillimantin 60Type acc. to DIN VDE 0335 C 799 C 610 C 530Chemical composition AL2O3 % 99,7 60 80Type of body Gasproof Gasproof PorousBulk density g/cm³ 3.8 2.7 2.4Application limit °C 1750 1600 1500Thermal conductivity 20-100°C W/mK 25 5 2Resistance to temperature changes Medium to good Good Very goodSpecial electrical resistance at RT Ω 1 x 1014 1 x 1013 -Special electrical resistance at 600°C 1 x 108 1 x 106 1 x 106

Ceramic protection tube closed on one end:

Insulation rod with 2, 4 or 5 holes:

Ceramic tube open at both ends:

Ext

erna

l Ø x

Inte

rnal

Ø

Length L = YYYY

Length L = YYYY

ØE

xter

nal Ø

x In

tern

al Ø

Length L = YYYY

2 holes 4 holes 5 holes SPLIT

Page 107: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page ��

Ceramic thermowells for thermocouples

Product group 99-EZT

Alsint 99.7 – C799

Dimensions Ø Da x Di x L mm Article numberØ 10 x 6 x 530 80-21100060-0530Ø 10 x 6 x 740 80-21100060-0740Ø 10 x 6 x 1030 80-21100060-1030Ø 10 x 6 x 1430 80-21100060-1430Ø 15 x 10 x 530 80-21150100-0530Ø 15 x 10 x 740 80-21150100-0740Ø 15 x 10 x 1030 80-21150100-1030Ø 15 x 10 x 1430 80-21150100-1430Ø 16 x 12 x 530 80-21160120-0530Ø 16 x 12 x 740 80-21160120-0740Ø 16 x 12 x 1030 80-21160120-1030Ø 16 x 12 x 1430 80-21160120-1430Ø 24 x 18 x 530 80-21240180-0530Ø 24 x 18 x 740 80-21240180-0740Ø 24 x 18 x 1030 80-21240180-1030Ø 24 x 18 x 1430 80-21240180-1430

Pythagoras – C610

Dimensions Ø Da x Di x L mm Article numberØ 10 x 7 x 530 80-11100070-0530Ø 10 x 7 x 740 80-11100070-0740Ø 10 x 7 x 1030 80-11100070-1030Ø 10 x 7 x 1430 80-11100070-1430Ø 15 x 11 x 530 80-11150110-0530Ø 15 x 11 x 740 80-11150110-0740Ø 15 x 11 x 1030 80-11150110-1030Ø 15 x 11 x 1430 80-11150110-1430Ø 16 x 12 x 530 80-11160120-0530Ø 16 x 12 x 740 80-11160120-0740Ø 16 x 12 x 1030 80-11160120-1030Ø 16 x 12 x 1430 80-11160120-1430Ø 24 x 19 x 530 80-11240190-0530Ø 24 x 19 x 740 80-11240190-0740Ø 24 x 19 x 1030 80-11240190-1030Ø 24 x 19 x 1430 80-11240190-1430

Sillimantin 60 – C530

Dimensions Ø Da x Di x L mm Article numberØ 26 x 18 x 530 80-01260180-0530Ø 26 x 18 x 740 80-01260180-0740Ø 26 x 18 x 1530 80-01260180-1530Ø 26 x 18 x 1230 80-01260180-1230Ø 26 x 18 x 1430 80-01260180-1430

Comment: Ceramic tubes open on both ends are available in the same dimensions. Special dimensions – on request !

Alsint 99.7 – C799

Dimensions Ø Da x Di x L mm Article numberØ 5.5 x 1.2 x 560 (2 holes) 81-02205512-0560Ø 5.5 x 1.2 x 770 (2 holes) 81-02205512-0770Ø 5.5 x 1.2 x 1060 (2 holes) 81-02205512-1060Ø 5.5 x 1.2 x 1460 (2 holes) 81-02205512-1460Ø 5.5 x 1.2 x 560 (4 holes) 81-02405512-0560Ø 5.5 x 1.2 x 770 (4 holes) 81-02405512-0770Ø 5.5 x 1.2 x 1060 (4 holes) 81-02405512-1060Ø 5.5 x 1.2 x 1460 (4 holes) 81-02405512-1460Ø 8.5 x 1.5 x 560 (2 holes) 81-02208515-0560Ø 8.5 x 1.5 x 770 (2 holes) 81-02208515-0770Ø 8.5 x 1.5 x 1060 (2 holes) 81-02208515-1060Ø 8.5 x 1.5 x 1460 (2 holes) 81-02208515-1460Ø 8.5 x 1.5 x 560 (4 holes) 81-02408515-0560Ø 8.5 x 1.5 x 770 (4 holes) 81-02408515-0770Ø 8.5 x 1.5 x 1060 (4 holes) 81-02408515-1060Ø 8.5 x 1.5 x 1460 (4 holes) 81-02408515-1460

Pythagoras – C610

Dimensions Ø Da x Di x L mm Article numberØ 5.5 x 1.2 x 560 (2 holes) 81-01205512-0560Ø 5.5 x 1.2 x 770 (2 holes) 81-01205512-0770Ø 5.5 x 1.2 x 1060 (2 holes) 81-01205512-1060Ø 5.5 x 1.2 x 1460 (2 holes) 81-01205512-1460Ø 5.5 x 1.2 x 560 (4 holes) 81-01405512-0560Ø 5.5 x 1.2 x 770 (4 holes) 81-01405512-0770Ø 5.5 x 1.2 x 1100 (4 holes) 81-01405512-1060Ø 5.5 x 1.2 x 1460 (4 holes) 81-01405512-1460Ø 8.5 x 1.5 x 560 (4 holes) 81-01408515-0560Ø 8.5 x 1.5 x 770 (4 holes) 81-01408515-0770Ø 8.5 x 1.5 x 1060 (4 holes) 81-01408515-1060Ø 8.5 x 1.5 x 1460 (4 holes) 81-01408515-1460Ø 8.5 x 1.5 x 560 (5 holes) 81-01508515-0560Ø 8.5 x 1.5 x 770 (5 holes) 81-01508515-0770Ø 8.5 x 1.5 x 1060 (5 holes) 81-01508515-1060Ø 8.5 x 1.5 x 1460 (5 holes) 81-01508515-1460

The insulation rods are available with one or with two slits for the welded measuring point if required.Comment: The thermowells and insulation rods specified above are a selection of the most widely-used dimensions. We will gladly make an offer for any other lengths or dimensions you may require.

Ceramic thermowells closed on one end:

Insulation rods:

Page 108: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page ��

Metal thermowells for thermocouples

Product group 99-EZT

The metal thermowells specified in this section are limited to those made of the most-widely used materials.Tubes of this kind are used for standard temperature measurements, mainly in gaseous and liquid media. The choice of thermowell will depend on the space available, the type of fastening and stresses caused by temperatures, pressure, flows and chemical corrosion.

Model with a semi-circular, closed base, the tube is seamlessly extruded or it has welded joints

Model with a closed round base, the tube is seamlessly extruded or it has welded joints

Material / Dimensions / Model Properties / Article number

1.0305 - Tube with a welded base, seamlessly extruded Mostly air case-hardened; low resistance to sulphurous gases, medium resistance to nitrogenous gases. Thermal stability up to 550°C15 x 2 mm 82-50041500-xxxx.020022 x 2 mm 82-50042200-xxxx.0200

1.4541 - Tube with welded base, seamlessly extruded High degree of corrosion-resistance to numerous aggressive media such as combustion gases. Resistant to particle decomposition in accordance with DIN 50914, to 700°C11 x 1 mm 82-50101100-xxxx.010015 x 2 mm 82-50101500-xxxx.020022 x 2 mm 82-50102200-xxxx.0200

1.4571 - Tube with a welded base, seamlessly extruded As 1.4541, but also corrosion-resistant to certain acids such as phosphoric, acetic and sulphuric acid due to the addition of approx. 2% molybdenum. Resistant to pitting, up to 700°C 9 x 1 mm 82-50010900-xxxx.010010 x 1.5 mm 82-50011000-xxxx.015011 x 1 mm 82-50011100-xxxx.010011 x 2 mm 82-50011100-xxxx.020015 x 2 mm 82-50011500-xxxx.020015 x 3 mm 82-50011500-xxxx.030022 x 2 mm 82-50012200-xxxx.0200

*) xxxx stands for the overall length of the required thermowell in mm.

*)

*)

*)

L = XXXX

L = XXXX

Out

er Ø

x w

w

Out

er Ø

x w

w

Page 109: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page ��

Metal thermowells for thermocouples

Product group 99-EZT

Material / Dimensions / Model Properties / Article number

1.4762 - Tube with semi-circular closed base, welded joints Good resistance properties to sulphurous gases; low resistance to nitrogenous gases, up to 1200°C15 x 2 mm 82-30021500-xxxx.020022 x 2 mm 82-30022200-xxxx.0200

1.4762 - Tube with welded base, welded joints Good resistance properties against sulphurous gases; low resistance to nitrogenous gases, up to 1200°C15 x 2 mm 82-20021500-xxxx.020022 x 2 mm 82-20022200-xxxx.0200

1.4841 - Tube with semi-circular closed base, welded joints Good resistance properties when used in nitrogenous gases; low resistance to sulphurous gases, operation temperature up to 1150°C15 x 2 mm 82-30031500-xxxx.020022 x 2 mm 82-30032200-xxxx.0200

1.4841 - Tube with welded base, welded joints Good resistance properties when used in nitrogenous gases; low resistance to sulphurous gases, operation temperature up to 1150°C15 x 2 mm 82-30031500-xxxx.020015 x 2 mm 82-20031500-xxxx.020022 x 2 mm 82-20032200-xxxx.0200

1.4893 - Tube with semi-circular closed base, welded joints Extremely good resistance properties in a reducing sulphurous atmosphere. Very good resistance properties in an oxidising atmosphere. Good resistance properties against corrosion caused by combustion ash, in copper, lead and zinc molten metals, up to 1150°C24 x 3 mm 82-60072400-xxxx.030026 x 4 mm 82-60072600-xxxx.0400

2.4816 - Tube with welded base, seamlessly extruded Good general corrosion resistance properties, resistant to stress corrosion cracking. Excellent resistance properties against oxidation. Not recommendable for gases containing CO2 and sulphur above 550°C and sodium above 750°C. Stable in air up to 1100°C. 14 x 2 mm 82-50081400-xxxx.020022 x 2 mm 82-50082200-xxxx.0200

*) xxxx stands for the overall length of the required thermowell in mm.

*)

Page 110: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page ��

Base-metal thermocouples

Product group 99-EZT

a) Base-metal thermocouples with both limbs insulated with single-hole insulation tubes for thermo-couples in product groups 00-TMT and 05-TKT

Type NiCr-Ni/K DIN IEC 584

Diameter Insulation Max. temp. Continuous temp. Article number1.0 mm Single-hole tube 2.7 x 1.7 x 50 mm C610 1000°C 800°C On request1.38 mm Single-hole tube 4 x 2 x 50 mm C610 1100°C 900°C 94-211382xx-xxxx1.5 mm Single-hole tube 4 x 2 x 50 mm C610 1100°C 900°C 94-211502xx-xxxx2.0 mm Single-hole tube 4.5 x 2.5 x 50 mm C610 1200°C 1000°C 94-212002xx-xxxx3.0 mm Single-hole tube 6 x 4 x 50 mm C610 1200°C 1000°C 94-213002xx-xxxx

Type Fe-CuNi/L DIN 43710

1.5 mm Single-hole tube 4 x 2 x 50 mm C610 800°C 600°C 94-221502xx-xxxx2.0 mm Single-hole tube 4 x 2 x 50 mm C610 900°C 700°C 94-222002xx-xxxx3.0 mm Single-hole tube 4 x 2 x 50 mm C610 900°C 700°C 94-223002xx-xxxx

Type Nicrosil-Nisil/N DIN IEC 584

1.5 mm Single-hole tube 4 x 2 x 50 mm C610 1100°C 1000°C 94-241502xx-xxxx2.0 mm Single-hole tube 4 x 2 x 50 mm C610 1200°C 1100°C 94-242002xx-xxxx3.0 mm Single-hole tube 4 x 2 x 50 mm C610 1200°C 1100°C 94-243002xx-xxxx

b) Base-metal thermocouples with one limb insulated for thermocouplesin product groups 00-TMT and 05-TKT

Diameter Insulation Max. temp. Continuous temp. Article number1.0 mm Single-hole tube 2.7 x 1.7 x 50 mm C610 1000°C 800°C 94-211002xx-xxxx1.38 mm Single-hole tube 4 x 2 x 50 mm C610 1100°C 900°C 94-211382xx-xxxx1.5 mm Single-hole tube 4 x 2 x 50 mm C610 1100°C 900°C 94-212002xx-xxxx2.0 mm Single-hole tube 4.5 x 2.5 x 50 mm C610 1200°C 1000°C 94-212002xx-xxxx3.0 mm Single-hole tube 6 x 4 x 50 mm C610 1200°C 1000°C 94-213002xx-xxxx

L = XXXX

L = XXXX

Type NiCr-Ni/K DIN IEC 584

Page 111: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page ��

Base-metal thermocouplesPrecious-metal thermocouples

Product group 99-EZT

a) Base-metal thermocouples with both limbs insulated with two-hole insulation tubes for thermo-couples in product groups 00-TMT and 05-TKT

Type NiCr-Ni/K DIN IEC 584

Diameter Insulation Max. temp. Continuous temp. Article number1.0 mm 2-hole tube C610 1000°C 800°C On request1.38 mm 2-hole tube C610 1100°C 900°C 94-211382xx-xxxx1.5 mm 2-hole tube C610 1100°C 900°C 94-211502xx-xxxx2.0 mm 2-hole tube C610 1200°C 1000°C 94-212002xx-xxxx3.0 mm 2-hole tube C610 1200°C 1000°C 94-213002xx-xxxx

Type Fe-CuNi/L DIN 43710

1.5 mm 2-hole tube C610 800°C 600°C 94-221502xx-xxxx2.0 mm 2-hole tube C610 900°C 700°C 94-222002xx-xxxx3.0 mm 2-hole tube C610 900°C 700°C 94-223002xx-xxxx

Precious-metal thermocouplesb) Precious-metal thermocouples, not insulated, for thermocouples in product groups 00-TMT and 05-TKT

Diameter Insulation Max. temp. Continuous temp. Article number0.35 mm PtRh13-Pt/R 1450°C 1300°C 94-110351xx-xxxx0.5 mm PtRh13-Pt/R 1600°C 1500°C 94-110501xx-xxxx0.35 mm PtRh10-Pt/S 1450°C 1300°C 94-100351xx-xxxx0.5 mm PtRh10-Pt/S 1600°C 1500°C 94-100501xx-xxxx0.35 mm PtRh30-PtRh6/B 1600°C 1500°C 94-120351xx-xxxx0.5 mm PtRh30-PtRh6/B 1800°C 1650°C 94-120501xx-xxxx

L = XXXX

L = XXXX

Page 112: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page ��

Fasteners

Product group 99-EZT

A) Stop flange for fastening the thermal sensor to the wall of the installation point

A B C d2 d3 Article numberDiameterThermowellor Holding tube[mm]15 75 50 55 26 16 89-11015001-000022 90 65 70 33 23 89-11022001-000026 to 29 90 65 70 35 29 89-11026001-000032 90 65 70 43 33 89-11032001-0000

B) Counter flange in connection with the stop flange for gasproof installation of the thermal sensor. The counter- flange is welded to the wall of the installation point.

A B C d1 d2 d3 Article numberDiameterMetalthermowell[mm]15 75 50 55 28 35 17 89-21015001-000022 90 65 70 39 43 24 89-21022001-000026 90 65 70 39 43 28 89-21026001-000032 90 65 70 39 43 34 89-21032001-0000

- Material: grey cast iron- Movable- Not gasproof

- Material: steel

A

Cd2d3

9.5

B

8

32

A

d1

6

40~

5

Page 113: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page 20

Fasteners

Product group 99-EZT

C) Mounting thread Gasproof, for screwing into the wall of the installation point

Tube-Ø Thread Length Length Collar SW1 SW2 Material/ Article number d1 G L1 L2 D Surface [mm] [mm] [mm] [mm] [mm] 12 G ½ A 16 60 27 27 27 Steel / zinc-coated 89-34212001-G01215 G ½ A 16 60 30 30 27 Steel / zinc-coated 89-34215001-G01215 G ½ A 16 60 27 27 27 Stainless steel 89-36115001-G01215 G ¾ A 18 60 32 32 27 Steel / zinc-coated 89-34215001-G03415 G ¾ A 18 60 32 27 27 Stainless steel 89-36115001-G03422 G 1 A 20 65 40 46 41 Steel / untreated 89-32122001-G10022 G 1 A 20 65 40 41 41 Steel / zinc-coated 89-34222001-G10032 G 1¼ A 25 75 49 50 46 Steel / burnished 89-33132001-G11432 G 1½ A 25 75 49 50 46 Steel / burnished 89-33132001-G112

D) Screw fastening for thermal sensors Ø 1.0 mm to Ø 10.0 mm Gasproof, for screwing into the wall of the installation point

Diameter Thread Length Length Collar Material/ Article number d1 G L1 L2 D Surface [mm] [mm] [mm] [mm]Ø 1.0 Clamping ring, Teflon M 8 x 1 8 20 11,5 zinc-coated 89-44501001-MF08Ø 1.5 Clamping ring, stainless steel M 8 x 1 8 20 11,5 Stainless steel 89-46401501-MF08Ø 2.0 Clamping ring, Teflon M 8 x 1 8 20 11,5 zinc-coated 89-44502001-MF08Ø 3.0 Clamping ring, stainless steel G ¼ A 12 25 18 Stainless steel 89-46403001-G014Ø 4.5 Clamping ring, Teflon G ¼ A 12 25 18 zinc-coated 89-44504501-G014Ø 6.0 Clamping ring, stainless steel G ½ A 14 30 26 Stainless steel 89-46406001-G012Ø 8.0 Clamping ring, Teflon G ½ A 14 30 26 zinc-coated 89-44508001-G012Ø 10.0 Clamping ring, stainless steel G ½ A 14 30 26 Stainless steel 89-44510001-G012

The installation length for clamping rings made of SS and steel can only be adjusted once when the sleeve nut is tightened; Teflon can be repeatedly adjusted.

Further information on request. Dimensions may deviate from those indicated.

Further information on request. Dimensions may deviate from those indicated.

Page 114: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page 2�

Fasteners

Product group 99-EZT

D) Screw fastening for thermal sensors Ø 1.0 mm to Ø 12.0 mm Gasproof, for screwing into the wall of the installation point

Further information on request. Dimensions may deviate from those indicated.

The installation length for clamping rings made of SS and steel can only be adjusted once when the sleeve nut is tightened; Teflon can be repeatedly adjusted.

Diameter Thread Length Length Collar Material/ Article number d1 G L1 L2 D Surface [mm] [mm] [mm] [mm]Ø 1.0 Clamping ring, Teflon M 8 x 1 8 20 11,5 Stainless steel 89-46501001-MF08Ø 1.0 Clamping ring, stainless steel M 8 x 1 8 20 11,5 zinc-coated 89-44401001-MF08Ø 1.5 Clamping ring, Teflon M 8 x 1 8 20 11,5 Stainless steel 89-46501501-MF08Ø 1.5 Clamping ring, Teflon M 8 x 1 8 20 11,5 zinc-coated 89-44501501-MF08Ø 1.5 Clamping ring, stainless steel M 8 x 1 8 20 11,5 Stainless steel 89-46401501-MF08Ø 1.5 Clamping ring, stainless steel M 8 x 1 8 20 11,5 zinc-coated 89-44401501-MF08Ø 2.0 Clamping ring, Teflon M 8 x 1 8 20 11,5 zinc-coated 89-44502001-MF08Ø 2.0 Clamping ring, Teflon M 8 x 1 8 20 11,5 Stainless steel 89-46502001-MF08Ø 3.0 Clamping ring, Teflon M 8 x 1 8 20 11,5 Stainless steel 89-46503001-MF08Ø 3.0 Clamping ring, Teflon M 8 x 1 8 20 11,5 zinc-coated 89-44503001-MF08Ø 3.0 Clamping ring, stainless steel M 8 x 1 8 20 11,5 Stainless steel 89-46403001-MF08Ø 3.0 Clamping ring, stainless steel M 8 x 1 8 20 11,5 zinc-coated 89-44403001-MF08Ø 3.0 Clamping ring, Teflon G A 8 20 11,5 Stainless steel 89-46503001-G018Ø 3.0 Clamping ring, Teflon G ¼ A 12 25 18 Stainless steel 89-46503001-G014Ø 3.0 Clamping ring, Teflon G ¼ A 12 25 18 zinc-coated 89-44503001-G014Ø 3.0 Clamping ring, stainless steel G ¼ A 12 25 18 Stainless steel 89-46403001-G014Ø 3.0 Clamping ring, stainless steel G ¼ A 12 25 18 zinc-coated 89-44403001-G014Ø 3.0 Clamping ring, Teflon G ½ A 14 30 26 Stainless steel 89-46503001-G012Ø 3.0 Clamping ring, stainless steel G ½ A 14 30 26 Stainless steel 89-46403001-G012Ø 4.5 Clamping ring, Teflon G ¼ A 12 25 18 Stainless steel 89-46504501-G014Ø 4.5 Clamping ring, Teflon G ¼ A 12 25 18 zinc-coated 89-44504501-G014Ø 4.5 Clamping ring, stainless steel G ¼ A 12 25 18 Stainless steel 89-46404501-G014Ø 4.5 Clamping ring, stainless steel G ¼ A 12 25 18 zinc-coated 89-44404501-G014Ø 4.5 Clamping ring, Teflon G ½ A 12 25 18 Stainless steel 89-46504501-G012Ø 4.5 Clamping ring, Teflon G ½ A 12 25 18 zinc-coated 89-44504501-G012Ø 4.5 Clamping ring, stainless steel G ½ A 12 25 18 Stainless steel 89-46404501-G012Ø 6.0 Clamping ring, Teflon G ¼ A 12 25 18 Stainless steel 89-46506001-G014Ø 6.0 Clamping ring, Teflon G ¼ A 12 25 18 zinc-coated 89-44506001-G014Ø 6.0 Clamping ring, stainless steel G ¼ A 12 25 18 Stainless steel 89-46406001-G014Ø 6.0 Clamping ring, stainless steel G ¼ A 12 25 18 zinc-coated 89-44406001-G014Ø 6.0 Clamping ring, Teflon G ½ A 12 25 18 Stainless steel 89-46506001-G012Ø 6.0 Clamping ring, Teflon G ½ A 12 25 18 zinc-coated 89-44506001-G012Ø 6.0 Clamping ring, stainless steel G ½ A 12 25 18 Stainless steel 89-46406001-G012Ø 6.0 Clamping ring, stainless steel G ½ A 12 25 18 zinc-coated 89-44406001-G012Ø 8.0 Clamping ring, Teflon G ½ A 12 30 18 Stainless steel 89-46508001-G012Ø 8.0 Clamping ring, Teflon G ½ A 12 30 18 zinc-coated 89-44508001-G012Ø 8.0 Clamping ring, stainless steel G ½ A 12 30 18 Stainless steel 89-46408001-G012Ø 8.0 Clamping ring, stainless steel G ½ A 12 30 18 zinc-coated 89-44408001-G012Ø 9.0 Clamping ring, Teflon G ½ A 12 30 18 Stainless steel 89-46509001-G012Ø 10.0 Clamping ring, Teflon G ½ A 12 30 18 Stainless steel 89-46510001-G012Ø 10.0 Clamping ring, Teflon G ½ A 12 30 18 zinc-coated 89-44510001-G012Ø 10.0 Clamping ring, stainless steel G ½ A 12 30 18 Stainless steel 89-46410001-G012Ø 12.0 Clamping ring, Teflon G ½ A 12 30 18 Stainless steel 89-46512001-G012Ø 12.0 Clamping ring, stainless steel G ½ A 12 30 18 Stainless steel 89-46412001-G012

Page 115: Datenblatt, Dataseet, Data Sheet, Katalog, Datenblätter ... · PDF fileNominal length Günther GmbH · Temperaturmesstechnik 00 - TMT // Thermocouples with a metal protection tube

Günther GmbH · Temperaturmesstechnik

Edition english 002 Page 22

Temperature transmitter

Product group 99-EZT

Günther PT Günther Art. no. : 88-01900002-0000

- Temperature transmitter, PC-programable

- Application: RTD (Pt100)

- 2-wire 4-20 mA

- Fault reaction: NAMUR NE 43

- Mounting: head form B, DIN 43729

Günther PCP Günther Art. no. : 88-01900011-0000

- Temperature transmitter, PC-programmable

- Application: RTD, TC, Ohm, mV

- 2-wire 4-20mA, galvanic isolation

- Fault reaction: NAMUR NE 43

- Mounting: head form B, DIN 43729

Günther PCP-HART Günther Art. no.: 88-01900012-0000

- Temperature transmitter, Protocol HART®

- Application: RTD, TC, Ohm, mV

- 2-wire 4-20mA, SIL2, galvanic isolation

- Fault reaction: NAMUR NE 43

- Mounting: head form B, DIN 43729

General

The task of transmitters is the transformation of the sensor signal into a stable and standardized signal. In the past, transmitters were built using analog technology. In the meantime digital technology has gained acceptance, however, because it offers better measurement accuracy at simultaneously higher flexibility, improve safety and safe costs. In addition, the measurement accuracy in modern transmitters can be improved by use ‚sensor-transmittermatching‘. The complete measurement point can be calibrated in a loop (Sensor and transmitter together).On the one hand, the standardized output signal in the process measurement is a 4...20 mA signal, but also the internationally standardized field bus HART®. The HART® protocol serves mainly for a more convenient operation in combination with the 4...20 mA analog measured signal.


Recommended