+ All Categories
Home > Documents > DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400...

DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400...

Date post: 18-Jan-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
12
SF-DCG15 www.daikinac.com 5/17 Supersedes 3/16 * Complete warranty details available from your local dealer or at www.daikincomfort.com. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons Heang Capacity: 350,000 BTU/h 20 Tons Heang Capacity: 400,000 BTU/h 25 Tons Heang Capacity: 400,000 BTU/h DCG Commercial 15 - 25 Tons Packaged Gas / Electric Units Standard Features • Patented tubular heat exchanger High-efficiency scroll compressor Aluminum micro-channel indoor coil on 25-ton units 25-ton units contain two outdoor fans Copper tube / aluminum fin coils High- and low-pressure switches High-capacity, steel-cased filter drier 24-volt terminal strip Contactor with lugs Units meet the performance outlined in Table 6.8.1-1 of ASHRAE Standard 90.1-2013 AHRI Cerfied; ETL Listed Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Condenser hail guards Full perimeter rail Built-in filter rack with standard 2” filters (converble to 4” filters) Sloped drain pan Job Name Locaon Purchaser Order No. Engineer Unit No. Model No. Unit Designaon Performance Data Cerfied By: Submittal Data Form
Transcript
Page 1: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

SF-DCG15 www.daikinac.com 5/17Supersedes 3/16

* Complete warranty details available from your local dealer or at www.daikincomfort.com.

15 Tons Cooling Capacity: 180,000 BTU/h20 Tons Cooling Capacity: 240,000 BTU/h25 Tons Cooling Capacity: 290,000 BTU/h15 Tons Heating Capacity: 350,000 BTU/h20 Tons Heating Capacity: 400,000 BTU/h25 Tons Heating Capacity: 400,000 BTU/h

DCG Commercial15 - 25 Tons Packaged Gas / Electric Units

■■ Standard Features• Patented tubular heat exchanger• High-efficiency scroll compressor• Aluminum micro-channel

indoor coil on 25-ton units• 25-ton units contain two outdoor fans• Copper tube / aluminum fin coils• High- and low-pressure switches• High-capacity, steel-cased filter drier• 24-volt terminal strip• Contactor with lugs• Units meet the performance outlined in Table

6.8.1-1 of ASHRAE Standard 90.1-2013 • AHRI Certified; ETL Listed

■■ Cabinet Features• Heavy-gauge, galvanized-steel cabinet

with UV-resistant powder-paint finish• Condenser hail guards• Full perimeter rail• Built-in filter rack with standard

2” filters (convertible to 4” filters) • Sloped drain pan

Job Name

Location

Purchaser

Order No.

Engineer

Unit No.

Model No.

Unit Designation

Performance Data Certified By:

Submittal Data Form

Page 2: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

2 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 3

Performance Data

Cooling PerformanceTota Capacity MBHSensible Capacity MBHOutdoor Design TMP ºF DB / WBAir Temp enteringEvaporator Coil ºFPower Input Required kW(less blower motor)

Heating PerformanceTotal Heating Capacity kW

BTU/h

Supply Air Blower PerformanceTotal Supply Air CFMExt. Static Pressure IWGBlower Speed RPMPower Output Required BHPMotor Ratings HPPower Input Required kW

Electrical DataPower SupplyTotal Unit Amps AmpsMax Overcurrent Device:Fuse Breaker Amps

Notes

Page 3: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

2 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 3

Dimensions — 15 & 20 Tons

35.5

51

7.01

750.7

50

88.1

1612

.137

8.20

4

3.05

8

133.

354

18.5

79

8.94

9

DC

*180

/240

***

15 A

ND

20

TON

CO

ME

RC

IAL

ALL

DIM

EN

SIO

NS

AR

E G

IVE

N IN

INC

HE

SA

LL D

IME

NS

ION

S A

ND

SP

EC

IFIC

ATI

ON

S A

RE

SU

BJE

CT

TO C

HA

NG

E W

ITH

OU

T N

OTI

FIC

ATI

ON

BA

CK

VIE

W

CO

ND

EN

SA

TED

RA

IN O

UTL

ET

THIS

SID

E O

NLY

FOR

K H

OLE

SB

OTH

SID

ES

AN

DC

ON

DE

NS

ER

EN

D

LIFT

SH

AC

KLE

HO

LES

BO

TH S

IDE

S A

ND

EN

DS

LEFT

EN

D V

IEW

TSTA

T W

IRE

E

NTR

AN

CE

LIN

E W

IRE

EN

TRA

NC

E

DIS

CO

NN

EC

T S

WIT

CH

LOC

ATI

ON

TOP

VIE

W

(if a

pplic

able

)

Page 4: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

4 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 5

Dimensions — 15, 20, & 25 Tons

2X 7.0002X 60.000

7.000

22.000

35.505

44.063

48.000

22.000

BASE PAN VIEW(VIEWED FROM TOP DOWN)

CONDENSATE DRAINBOTTOM EXIT

RETURN AIR DUCT

SUPPLY AIR DUCT

Page 5: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

4 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 5

Dimensions — 25 Tons

8.20

4

3.05

8

12.1

25

88.1

16

7.01

7

50.7

50

35.5

51

133.

354

53.2

12

TOP

VIE

W BA

CK

VIE

W

LEFT

EN

D V

IEW

DC

*300

***

25-T

ON

C

OM

ME

RC

IAL

ALL

DIM

EN

SIO

N G

IVE

N A

RE

IN IN

CH

ES

ALL

DIM

EN

SIO

NS

AN

D S

PE

CIF

ICA

TIO

NS

AR

E S

UB

JEC

T TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E.

CO

ND

EN

SA

TED

RA

N O

UTL

ET

THIS

SID

E O

NLY

FOR

K H

OLE

SB

OTH

SID

ES

AN

DC

ON

DE

NS

ER

EN

D

LEFT

SH

AC

KLE

HO

LES

BO

TH S

IDE

S A

ND

EN

DS

TSTA

T W

IRE

EN

TRA

NC

E

LIN

E W

IRE

EN

TRA

NC

E

Page 6: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

6 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 7

Accessories List

Daikin Master Item #

Description FitsModel Sizes

Field-Installed

Factory-Installed √

Curb

14CURB180300 14” Roof Curb 15-25 tons √

18CURB180300 18” Roof Curb 15-25 tons √

24CURB180300 24” Roof Curb 15-25 tons √

GHRC-180300 Hurricane Restraint Clips 15-25 tons √

Ultra Low-Leak Economizer & Power Exhaust1

10-365-11C Ultra Low-Leak Downflow Economizer w/ Dry Bulb 15-25 tons √

10-366-11C Ultra Low-Leak Downflow Economizer w/ Enthalpy 15-25 tons √ √

10-455-11-23 Centrifugal Power Exhaust 230v 15-25 tons √

10-455-11-33 Centrifugal Power Exhaust 460v 15-25 tons √

10-455-11-43 Centrifugal Power Exhaust 575v 15-25 tons √

10-457-11xA-23 Modulating Power Exhaust 230v 15-25 tons √

10-457-11xA-33 Modulating Power Exhaust 460v 15-25 tons √

10-465-11-21 Prop Power Exhaust 230v 15-25 tons √

10-465-11-31 Prop Power Exhaust 460v 15-25 tons √

10-465-11-41 Prop Power Exhaust 575v 15-25 tons √

Low-Leak Economizer & Power Exhaust2

DDNECNJ180300B Low-Leak Downflow Economizer 15-25 tons √ √

DPE1803002 Downflow Power Exhaust (208/230v) 15-25 tons √

DPE1803004 Downflow Power Exhaust (460v) 15-25 tons √

DPE1803007 Downflow Power Exhaust (575v) 15-25 tons √

DHZECNJ180300 Horizontal Economizer 15-25 tons √

Downflow Accessories

D25FD180300 25% Manual Fresh Air Damper 15-25 tons √

D25MFD180300 25% Motorized Fresh Air Damper 15-25 tons √

D50MFD180300 50% Motorized Fresh Air Damper 15-25 tons √

DDNBB180300 Burglar Bar Sleeves with Supply and Return 15-25 tons √

Horizontal Accessories

HZCURB180300EDR Horizontal Curb End Discharge Roofed In 15-25 tons √

HZCURB180300NSR Horizontal Curb Non-Service Side Discharge Roofed In 15-25 tons √

HZCURB180300SSR Horizontal Curb Service Side Discharge Roofed In 15-25 tons √

HZCURB180300EDS Horizontal Curb End Discharge Slab Mount 15-25 tons √

HZCURB180300NSS Horizontal Curb Non-Service Side Discharge Slab Mount 15-25 tons √

HZCURB180300SSS Horizontal Curb Service Side Discharge Slab Mount 15-25 tons √

DHZE25FD180300 Horizontal Fresh Air Damper 25% 15-25 tons √

DHZRETPNL180300 Horizontal Return Panel 15-25 tons √

Concentrics

CDK180 Concentric Duct Kit 15 tons √

CDK240 Concentric Duct Kit 20 tons √

CDK300 Concentric Duct Kit Flush Mount Diffuser 25 tons √

DDC Accessories3

DDC communicating controller (built-in BACnet® MS/TP) includes Standard Room Sensor to be installed in field 15-25 tons √

10366D11B DDC Ultra Low-Leak Downflow Economizer 15-25 tons √ √

Page 7: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

6 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 7

Accessories List (Cont.)

Daikin Master Item #

Description FitsModel Sizes

Field-Installed

Factory-Installed √

10465DDC Power Exhaust kit used with DDC Ultra Low-Leak Economizer 15-25 tons √

DLAKT03 Low-Ambient 15-20 tons √ √

LONKT01 LonWorks® card 15-25 tons √

3PMK01 Phase Monitor (3-Phase Only) 15-25 tons √ √

DFSKT02 Dirty Filter Switch 15-25 tons √

High-Static Kits4

HSKT180G High-Static Kit (230/460v) 15 tons √ √

HSKT180G-7 High-Static Kit (575v) 15 tons √ √

HSKT240 High-Static Kit (230/460v) 20 tons √ √

HSKT240-7 High-Static Kit (575v) 20 tons √ √

HSKT300G High-Static Kit (all voltages) 25 tons √ √

Crankcase Heater Kits

0130L00017S 70W 230V 15-20 tons √

0130L00018S 70W 460V 15-20 tons √

0130L00019S 70W 575V 15-20 tons √

0130L00020S 90W 230V 25 tons √

0130L00021S 90W 460V 25 tons √

0130L00022S 90W 575V 25 tons √

High Efficiency Filters

0160L00202 High Efficiency MERV 13 Air Filter Nom. Size: 20x25x2; (Order Qty 6) 15, 20 tons √

0160L00201 High Efficiency MERV 13 Air Filter Nom. Size: 20x20x2; (Order Qty 8) 25 tons √

Misc Accessories

Convenience Outlet: Powered 15-25 tons √

Convenience Outlet: Non Powered 15-25 tons √

Disconnect Switch (non-fused) 15-25 tons √

LAKT23 Low-Ambient Kit, 208-230V - non-DDC 15-20 tons √ √

LAKT24 Low-Ambient Kit, 460V - non-DDC 15-20 tons √ √

LAKT25 Low-Ambient Kit, 575V - non-DDC 15-20 tons √ √

LAKT05 Low-Ambient Kit (all voltages) - non-DDC 25 tons √ √

LPKT180300A LP Conversion Kit 15-25 tons √

3PMNDK01 Phase Monitor - non-DDC 15-25 tons √ √

Smoke Detector (supply and/or return air) 15-25 tons √

Hinged Panels 15-25 tons √

FSKT02A Freeze Stat Kit5 25 tons √

HAKT36300 High-Altitude Kit 15-25 tons √

LPKT180300A LP Conversion Kit 15-25 tons √

220-GX-003 Flue Extension Kit 15-25 tons √1 Use Economizer & Power Exhaust listed within Ultra Low-Leak section 2 Use Economizer & Power Exhaust listed within Low-Leak section 3 For a full list of DDC accessories, please refer to DDC Controller Technical Guide manual (DK-DDC-TGD-01B)4 HSKT High-Static Kits are for use with standard single-speed belt-drive units only. 5 FSK02A is standard on 2 speed, V, models, and field installed for single speed, B, models.

Note: Where multiple variations are available, the heaviest combination is listed.

Page 8: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

8 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 9

Specifications

• 14-Gauge Construction• 1 x 4 Wood Nailer attached to top of the curb• Shipped knocked down with all hardware• Gasket included• Bed-Rail style corners

Note: outside duct dimension should be ½” less than opening dimensions above.

Roof Curb — #14CRB180300

DD

CC

BB

AA

4

4

3

3

2

2

1

1

REV

SCALE

CSIZE

14CURB180-240

TITLE

DWG NO

4/28/2010mikeg

APPROVED

MFG

QA

CHECKED

DRAWN

1OF 1SHEET

CURB TOP O.D.123.5

TOP O.D. CURB

7861.88

22

4

44

CURB I.D.120.25

17.2517.25 17.25

CURB BOTTOM O.D.77.5

S/A R/A

PANELSINSULATED

31.751.75

22.88

14

TYP.1.63

CURB BOTTOM O.D.123 TYP.1.38

11.25

CURB I.D.74.75

61.88

S

Page 9: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

8 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 9

25FD180240 AND 25MFD180240 MANUAL / MOTORIZED FRESH AIR DAMPER

SPECIFICATIONSMANUAL DAMPER

PROVIDES UP TO 25% FRESH AIR•LOCKING SELECTION KNOB PROVIDES CONSTANT OPENING•

MOTORIZED DAMPER24VAC DAMPER MOTOR WITH SPRING RETURN•FULLY ASSEMBLED AND FACTORY WIRED•

FITS ALL 15-20 TON PACKAGE UNITS IN ALL FUELSALL DAMPERS PAINTED TO MATCH THE UNIT

McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX

SpecificationsManual Damper

• Provides up to 25% fresh air• Locking selection knob provides constant opening• Painted to match the unit • Fits 15 - 25 ton package units in all fuels

Motorized Damper• 24 VAC Damper motor with spring return• Fully assembled and factory wired • Painted to match the unit • Fits 15 - 25 ton package units in all fuels

Manual Fresh Air Damper — #D25MFD180300Motorized Fresh Air Damper — #D25MFD180300

Page 10: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

10 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 11

Specifications• Fully modulating• Up to 100% fresh air• Integral barometric relief• Hoods painted to match unit• Honeywell economizer control• Single adjustable enthalpy control convertible to dual enthalpy• Adjustable minimum fresh air• Factory wired• Gas/Electric for 15 - 25 ton units

Downflow Economizer — #DDNECNJ1803000B

Page 11: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

10 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com 11

Power Exhaust for 208/230v Units — #DPE1803002Power Exhaust for 460v Units — #DPE1803004Power Exhaust for 575V units - #DPE1803007

Specifications• Features propeller-type fans• 208/230V and 460V models available • Used in conjunction with DNECONHP150

or DNECONGS180240• Fans engage when economizer

fresh-air dampers are 70% open• Gives up to 100% relief• Integrates into downflow economizer hood

Page 12: DCG Commercial · 2017. 5. 11. · McDANIEL METALS 1318 BUSCHONG HOUSTON TX 77039 281-987-8400 281-987-9494 FAX Specifications Manual Damper • Provides up to 25% fresh air • Locking

Job Name Location Job Name Location

12 www.daikinac.com SF-DCG15 SF-DCG15 www.daikinac.com PB

Our continuing commitment to quality products may mean a change in specifications without notice. © 2017 • Houston, Texas • Printed in the USA.

Concentric Duct Kits — #CDK180, #CDK240 & #CDK300

Specifications• All-aluminum diffuser with aluminum return air egg crate• Built-in anti-sweat gasket• Molded fiberglass transition (through five tons)• Built-in hanging supports• Diffuser box constructed of fiberglass duct board

(through 7½ tons) or sheet metal

CommercialT-Bar Ceiling

Light CommercialT-Bar Ceiling

AluminumEgg Crate

MoldedFiberglassTransition

Turing Vane to Ensure Proper Airflow

Hanging Support from the Diffuser


Recommended