DCN-16U Exchange (basic version, version with pre-installed switching module DCN-Q4E) ARMT.665200.001UM User Manual Document version 18-11 26.30.11.190 2020
Transcript
Page 1: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U Exchange (basic version, version with pre-installed switching module DCN-Q4E) ARMT.665200.001UM

User Manual

Document version 18-11 26.30.11.190 2020

Page 2: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

armtel.com © Armtel [email protected]

Page 3: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 1/44 [email protected] © Armtel

INTRODUCTION

This User Manual is intended for introducing DCN-16U Exchange of ARMT.665200.001 basic version and version ARMT.665200.001-01 with pre-installed switching processor module DCN-Q4E (4xE1) ARMT.665200.010 to the User.

DCN-16U exchange is a compact connection unit for subscriber equipment within the DCN distributed of Public Address and General Alarm system.

Short product name – DCN-16U.

Maintenance personnel for the DCN-16U shall be appointed by the management at the installation site.

The maintenance personnel shall be required to know the operating procedure of the DCN-16U to the extent provided for by the user manual.

Duties of the maintenance personnel shall include maintenance of the DCN-16U in accordance with this user manual.

ATTENTION! In connection with systematic work to improve the design and manufacturing technology, it is possible some discrepancy between the description and the supplied product, which does not affect its operation or maintenance.

Page 4: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 2/44 armtel.com © Armtel [email protected]

SAFETY PROVISIONS

During installation and operation of DCN-16U, observe safety precautions laid out in local regulations on electrical safety.

To avoid electric shock, do not:

− operate the product if its case is not connected to the ground rod;

− operate the product with a damaged power or communication cable;

− the interface cable can be connected and disconnected if the power cable is disconnected.

ATTENTION! NEVER DISMANTLE THE PRODUCT CONNECTED TO MAINS.

Do not use the product in rooms with high humidity of more than 80% or conductive dust.

In order to ensure fire safety, follow the following rules:

− before connecting the product to the power supply, make sure the power and communication cables are properly insulated;

− protect power and communication cables from damage.

The safety provisions for specific operations described in this manual are marked with:

Page 5: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 3/44 [email protected] © Armtel

CONTENTS INTRODUCTION .................................................................................................................................................................... 1 SAFETY PROVISIONS ........................................................................................................................................................... 2 CONTENTS .............................................................................................................................................................................. 3 1 DESCRIPTION AND OPERATION ................................................................................................................................. 5

1.1 Product description and operation .................................................................................................................. 5

1.1.1 Functions ........................................................................................................................................................... 5

1.1.2 Main specifications ........................................................................................................................................ 7

1.1.3 Scope of supply ............................................................................................................................................ 10

1.1.4 Design............................................................................................................................................................... 11

1.2 Product components description and operation ...................................................................................... 14

1.2.1 General ............................................................................................................................................................. 14

1.2.2 DCN-Q4E (4xE1) switching processor module .................................................................................. 14

1.2.3 DCN-Q4E E1 connection cable ............................................................................................................... 16

1.2.4 DCN-16U subscribers connection cable .............................................................................................. 17

1.3 Subscriber units connected to DCN-16U (with DCN-Q4E) .................................................................... 18

1.3.1 General information .................................................................................................................................... 18

1.3.2 DCN-2 Exchange / DCN-Q4E switching processor module (to DCN-16U with DCN-Q4E) .................................................................................................................................................................. 18

1.3.2 Digital ATX (to DCN-16U with DCN-Q4E) .......................................................................................... 18

1.3.3 Subscriber units ............................................................................................................................................ 18

2 INTENDED USE ................................................................................................................................................................ 21 2.1 Operating limits ..................................................................................................................................................... 21

2.2 Preparation for use ............................................................................................................................................... 21

2.3 Safety precautions ................................................................................................................................................. 22

2.4 Installation, connection and dismantling ..................................................................................................... 23

2.5 Operation ................................................................................................................................................................. 24

2.5.1 Product On/Off ............................................................................................................................................. 24

2.5.2 Product general performance monitoring routine .......................................................................... 25

2.5.3 Troubleshooting ........................................................................................................................................... 28

3 MAINTENANCE ................................................................................................................................................................ 30 4 REPAIR .............................................................................................................................................................................. 31 5 STORAGE ............................................................................................................................................................................ 32 6 TRANSPORTATION ......................................................................................................................................................... 33

Page 6: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 4/44 armtel.com © Armtel [email protected]

7 DISPOSAL ........................................................................................................................................................................... 34 ANNEX А (reference) Сonnecting optional equipment and power supply ................................................. 35

А.1 DCN-Q4E E1 connection cable ........................................................................................................................ 35

А.2 DCN-16U digital subscribers connection cable ......................................................................................... 38

А.3 Connection to power supply ............................................................................................................................ 41

А.4 Phantom power supply ....................................................................................................................................... 42

Page 7: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 5/44 [email protected] © Armtel

1 DESCRIPTION AND OPERATION

1.1 Product description and operation

1.1.1 Functions

DCN-16U is designed to operate as a part of DCN-2 or DCN-Q4E-based DCN communication system as a module of digital subscriber sets to connect the subscriber devices via Uk0-interface. DCN-16U transmits voice traffic channels and signaling among 15 subscriber Uk0-interfaces and E1 line to a central exchange unit, and it doesn’t function as an exchange for connections between subscribers. Armtel DCN communication systems built-up using these products provides for voice communication between loud-speaking subscriber units made by Armtel LLC, VoIP subscribers, public address and general alarm.

Base version of DCN-16U has advanced features in version with preinstalled DCN-Q4E switching processor module.

DCN-16U Exchange of ARMT.665200.001-01 version has pre-installed switching processor module DCN-Q4E (4хЕ1) ARMT.665200.010, which is a small central exchange unit of DCN system and provides for switching voice channels up to four E1 lines enabling to connect a subscriber switching unit for 15 digital or analogue interfaces to each of them. Therefore, maximum capacity of DCN-Q4E-based system can be up to 60 subscribers.

The switching processor module DCN-Q4E intended for use as central exchange unit of DCN system, at the enterprise of industry and transport. DCN system (Armtel LLC) built with product provide simplex communication between loud-speaking subscriber devices manufactured by Armtel LLC, duplex communication with telephony subscribers, paging, and emergency loud warning.

DCN-16U is installed in control or office rooms.

DCN-16U Exchange both versions are shown in Figure 1.

Page 8: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 6/44 armtel.com © Armtel [email protected]

a) version ARMT.665200.001 (base version)

b) version ARMT.665200.001-01 (with pre-installed switching processor module DCN-Q4E)

Figure 1 – DCN-16U Exchange

In DCN-16U Exchange with DCN-Q4E switching processor module DCN-16U Exchange can be directly connected to a built-in processor module DCN-Q4E. This version of the product may function as central exchange of DCN system, enabling connection up to 15 digital subscriber units and three E1 lines to it to communicate with DCN system exchange units or other equipment.

Digital communication system DCN has flexible distributed structure, where single stations are linked into a single network by E1 digital lines. DCN communication system station (or central exchange) consists of DCN-2 or DCN-Q4E central exchange with DCN-16U and DCN-15A exchange equipped with digital and analogue subscriber interfaces connected to it by E1 lines. E1 lines can also be used as ISDN PRI lines to communicate with external telecommunication systems or to connect multichannel communication recorders. DCN IP-gateway providing communication with different IP-devices can also be used as DCN system station.

Each DCN-16U exchange is a subscriber lines equipment module with 16 Uk0-interfaces for connecting digital subscriber devices, and an E1 interface for connecting to a DCN central exchange (16th interface is not used). Digital subscriber interfaces enable to connect both Armtel equipment (DIS, DW, А8, DWEx, DTS5, Analogue subsystem module), and third-party equipment with Uk0-interface (ISDN telephones, ISDN adapters for analogue telephone connection, DECT stations with ISDN interfaces etc.). In order to improve intercom system quality when operating Armtel subscriber units, an expanded sound transmit frequency band of 6.8 kHz is used. DCN-16U is connected to a central exchange of DCN system by E1 line, which is used for transmitting voice traffic channels and signaling between the central exchange and subscriber units. Therefore, all functions of communication and control of subscriber units are implemented in the central exchange of DCN system and DCN-16U subscriber exchange performs no functions if not connected there to.

Page 9: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 7/44 [email protected] © Armtel

Being a part of DCN digital intercom system DCN-16U exchange functions as follows:

− Connection of up to 15 devices by the lines of digital double-wire subscriber interfaces Uk0 at a distance of max. 6 km.

− Transmission of voice communication channels and signaling between E1 line used for connection to DCN system central exchange and 15 digital subscriber interfaces Uk0.

− Control and indication on the front panel of subscriber interface and E1 line status.

− Phantom power supply of end units by Uk0 subscriber interface line.

Being a part of DCN digital intercom system DCN-16U Exchange provides for connection with the following devices:

− DIS and DIS-TOP digital desktop call stations.

− DW/DWEx explosion and weather proof digital loud-speaking call stations.

− DTS5 and DTS-TOP multifunction desktop digital phones.

− Analogue subsystem modules for communication with analogue equipment (one LF-interface line) and и switching control circuits (eight discrete input/output lines).

− А8/A8Ex explosion and weather proof digital duplex call stations (currently out of production).

− ISDN-telephones and other third-party devices with Uk0-interface.

DCN-16U Exchange is ready for operation as supplied and no programming is required during operation except for assignment of subscriber unit connection ports. Operation of DCN-16U Exchange and subscriber units connected to it is managed by a central exchange of DCN system connected to DCN-16U via E1 line.

Detailed description of functions and programming methods of DCN system exchange units are given in RMLT.465275.002 “DCN Communication System. User Manual. Part 1. User Manual” and “DCN Communication System. User Manual. Part 2. Administrator Manual”.

1.1.2 Main specifications

DCN-16U exchange has the following interfaces:

− 16 double-wire subscriber interfaces Uk0 – for basic access to end equipment. 16th interface is not used.

− Two serial interfaces RS-232 (V.24) – for PC connection at bit rate up to 115 kB/s, used for diagnostics and programming of the exchange at the manufacturer.

Page 10: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 8/44 armtel.com © Armtel [email protected]

− E1 (G.703/G.704) – for connection to DCN system central exchange via E1 line.

Uk0 interface provides for:

− Distance from the exchange to a subscriber is up to 6 km when using non-symmetrical cable.

− Bandwidth for voice transmission – 6.8 kHz (when using two B-channels).

− Phantom power supply to subscriber units using PoU (Power-over-U) function at load current up to 250 mA.

− ANSI T1.602 – interface of base channel, it is a procedure of accessing to a primary channel, D-channel (LAP-D), communication protocol is BRI.

− Coding the signal in the line – as per 2B1Q pattern according to ITU-T recommendation.

The product supports standard communications protocols as follows:

− Q.931 – for procedure of establishing network-level communication of OSI model (third-level specification for D-channel), provides for managing calls and a set of options, circuit switched call routing of service subscriber;

− I.452 (Q.932) – general procedures for ISDN options managing;

− Q.921 (LAP-D) – to determine frame structure and frame field content at channel level of OSI model (D-channel), User-Network interfaces is ISDN – specification of communication data level;

− I.430 of recommendations of ITU-T (ISDN standard) – for organizing data transmission at physical level of OSI model and basic access;

− I.431 of recommendations of ITU-T (ISDN standard) – for organizing data transmission at physical level of OSI model and main access;

− ANSI T1.604 – minimum set of services of ISDN BRI;

− I.432 of recommendations of ITU-T (ISDN standard) – User-network interface B-ISDN – physical level specification;

− DSS1 – subscriber signaling protocol.

Main specifications and performance characteristics of DCN-16U Exchange are given in the Table 1.

Page 11: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 9/44 [email protected] © Armtel

Table 1 – Main specifications

Parameter Value

Rated voltage, V -48

Supply voltage range, V from -36 to -60

Consumption power, at most, (excluding phantom supply), W 20

Maximum number of switched subscriber devices, pcs. 15

Electrical protection class (under GOST IEC 61140-2012) III

Climatic category (under GOST 15150-69) NF4.11)

Protection degree provided by shells (under GOST 14254-2015) (IP-code) IP40

Seismic resistance category (under NP-031-01) I

Safety Class (under NP-001-15*) 3Н (Normal)

Operating temperature range, ºC from - 5 to + 55

Atmospheric pressure, kPa from 84 to106,7

Relative air humidity at 25 °С, % up to 80

Dimensions, maximum, mm 483×227×44

Weight, max, kg (excluding weight of DCN-16U subscribers connection cables and DCN-Q4Е E1 connection cable) 2,5

* The product conformity with Safety Class 4Н under NP-001-15. 1) Conditioned locations or partially conditioned air.

The product enables/disables the configured subscriber units without power shutdown and reboot. DCN-16U has protection against incorrect polarity of power supply connection.

ATTENTION: WHEN CONNECTING PHANTOM POWER ADHERENCE TO INSTRUCTIONS OF MANUALS FOR CONNECTED SUBSCRIBER UNITS IS SCTRICTLY REQUIRED! FAILURE TO FOLLOW THE REQUIREMENTS MAY CAUSE DAMAGE TO

THE EXCHANGE AND/OR SUBSCRIBER UNIT!

Page 12: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 10/44 armtel.com © Armtel [email protected]

1.1.3 Scope of supply

Scope of supply for DCN-16U is given in the Table 2.

Table 2 – Scope of supply

Identification Name Quantity, pcs. Note

ARMT.665200.001* DCN-16U Exchange 1

Additional information on scope of supply

ARMT.665200.102 DCN-16U Subscribers connection cable 1

ARMT.665200.103 ISDN PRI (E1) module 1

ARMT.665200.010** Switching processor module DCN-Q4E (4хE1) 1

ARMT.665200.139** DCN-Q4Е Connection cable via Е1 1

PC 4/3-STF-7,62 socket 1

MJ-C-6,47 jumper 32

Operational documentation

ARMT.665200.001PP Product Passport 1

ARMT.665200.001UM User Manual 1

* Version according to the contract for the supply ** For version ARMT.665200.001-01

Page 13: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 11/44 [email protected] © Armtel

1.1.4 Design

DCN-16U Exchange mounted into a 19-inch rack (cabinet). DCN-16U external and overall dimensions are shown in the Figure 2.

Figure 2 - DCN-16U external and overall dimensions

Front panel of DCN-16U with pre-installed DCN-Q4E module and connector and LED indicators is shown in the Figure 3.

Figure 3 – DCN-16U Front panel

Note – All LEDs used in Front panel are two-color.

DCN-16U Front panel contains:

− CTRL – RJ-12 process connector (not used);

− PRG – hidden button for enabling software loading mode (used in initial loading of software at manufacturer);

− CPU – CPU1 (top) status indicator CPU, CPU2 is not used;

− RST – reset button;

Page 14: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 12/44 armtel.com © Armtel [email protected]

− 1…4 – indicators of 1…4 E1 line connection status. During operation indicator of E1 line used for connection to DCN central exchange is only active (E1 line 4 used by default);

− RS-232 (1 and 2) – RS-232 interface sockets for PC connection at product diagnostics and configuration at manufacturer;

− TDM – 1…4 (RJ-45 type) sockets for PCM cable connections (not used);

− 1…16 U – indicators of subscriber unit connection port status. Port 16 is not used;

− +5, +3 – indicators of + 3.3 V, + 5 V voltages of secondary power supply;

− А1, А2 – Failure 1, Failure 2. In case of failure signals states of A1, A2 indicators are equal to the states of К1, К2 error relays;

− FUSЕ – group of indicators of fuse state:

− SYS – status indicator of DCN-16U Main system fuse, installed in main supply voltage circuit 48 V;

− EXT – external failure source status indicator;

− 1…4 – status indicators of subscriber phantom power fuses.

Front panel of DCN-Q4E (only in version with DCN-Q4E module). is shown in the Figure 4.

Figure 4 – DCN-Q4E Front panel

DCN-Q4E Front panel contains:

− «1…4» Е1 – Е1 port status indicators (connected devices);

− ETHERNET – RJ-45 interface socket for remote access to DCN-Q4E from PC;

− CPU – CPU1 (top) is CPU status indicator, CPU2 (bottom) reserved;

− RST – CPU reset button;

− DSP – DSP1 (top) is DSP status indicator, DSP2 (bottom) – DSP with CPU link status;

− RS-232(3) – serial interface socket for diagnostic computer connection.

Page 15: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 13/44 [email protected] © Armtel

Back panel of DCN-16U with connectors and fuses is shown in the Figure 5.

Figure 5 – DCN-16U Back panel

DCN-16U Back panel contains:

− terminals for DCN-16U case grounding;

− DCN-Q4U Lines blank cover;

− Fuses – group of power supply fuses 5×20 2 А 250 V:

− PoU 1…16 – subscriber phantom power fuses, groups by 4 Uk0 ports;

− Main – DCN-16U system fuse installed in 48V supply voltage circuit of the main board.

− -48 0V GND – three-pin plug of DCN-16U power cable connection;

− Fantom Power – jumper strip for phantom power supply to subscriber units;

− Subscriber Lines Uk0 – 64-pin plug of DIN41612С-64М, to which DCN-16U subscribers connection cable socket is connected.

− DCN-Q4U Lines – 25-pin socket DRB-25FA of DCN-Q4Е E1 connection cable (only in version with DCN-Q4E module).

Page 16: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 14/44 armtel.com © Armtel [email protected]

1.2 Product components description and operation

1.2.1 General

DCN-16U components are as follows:

− DCN-Q4E switching processor module (only in DCN-16U with DCN-Q4E module);

− DCN-Q4Е E1 connection cable (only in DCN-16U with DCN-Q4E module);

− DCN-16U subscribers connection cable.

1.2.2 DCN-Q4E (4xE1) switching processor module

DCN-Q4E switching module is designed for creating small DCN system. It is an exchange unit with four E1-interfaces. DCN-Q4E functions are similar to those of DCN-2. DCN-Q4E switching module enables to build up industrial communication system suitable for up to 60 digital and analogue subscribers connection with DCN-2 functionality being available to them.

As a part of digital intercom DCN system DCN-Q4E switching processor unit provides for the functions as follows:

− switching digital communication channels between E1 line used for access to subscriber and other exchange units of ISDN network;

− two-way voice communication between subscriber units;

− individual call of any subscriber

− call group of subscribers;

− single PA/GA of subscribers by intercom;

− zonal (group) PA/GA of subscribers by intercom;

− free subscriber numbering;

− order of subscriber call preference with possibility of arbitrary assignment of connection priorities;

− playback of pre-recorded audio fragments;

− manual or automatic playback of recorded alarm signals, announcements and messages;

− unification of two or more central DCN exchanges to integrated communication system;

Page 17: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 15/44 [email protected] © Armtel

− connection of external Exchanges to DCN communication system by ISDN PRI lines;

− local and remote (via IP-network) monitoring, diagnostics and configuring of the central ex-change and subscriber units connected to it.

В DCN-Q4E has the following interfaces:

− 4 E1 (G.703/G.704) lines – for connection of subscriber exchanges DCN-16U, DCN-15A, DCN modules IP-gateway, multichannel digital communications recorders, other stations of DCN system and digital ATX;

− Ethernet (RJ-45 socket) – for remote access to DCN-2 Exchange central processor from system administrator’s PC via IP-network;

− RS-232 (V.24) – serial interface, process connector for service purposes.

The product supports standard communications protocols as follows:

− Q.931 – for procedure of establishing network-level communication of OSI model (third-level specification for D-channel), provides for managing calls and a set of options, circuit switched call routing of service subscriber;

− I.452 (Q.932) – general procedures for ISDN options managing;

− Q.921 (LAP-D) – to determine frame structure and frame field content at channel level of OSI model (D-channel), User-Network interfaces is ISDN;

− I.430 of recommendation of CCITT (ISDN standard) – for organizing data transmission at physical level of OSI model and basic access;

− I.431 of recommendations of CCITT (ISDN standard) – for organizing data transmission at physical level of OSI model and main access;

− ANSI T1.604 – minimum set of services of ISDN BRI;

− I.432 of recommendations of CCITT (ISDN standard) – User-network interface B-ISDN – physical level specification;

− DSS1 – subscriber signaling protocol.

In terms of design DCN-Q4E module being a part of DCN-16U Exchange is a printed circuit board to be enclosed into DCN-16U exchange, and powered from its main board. E1 line is connected through DRB-25FA socket on the back panel of the module by means of special cable. The product enables/disables devices by E1 lines without power shutdown and reboot.

Page 18: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 16/44 armtel.com © Armtel [email protected]

The Figure 6 shows DCN-Q4E module board with overall dimensions.

Figure 6 – DCN-Q4E board with overall dimensions

Maximum height of the parts on the board doesn’t exceed 30 mm.

There are electronic parts on DCN-Q4E module for its connection and functioning, including:

− А1 – connector for VDX-6300-based (ICOP) CPU module;

− Х1 – debugging connector for communication with DSP signal processor unit;

− Х5 – 25-pin socket DRB-25FA for E1 cable connection;

− Х6 – socket for connection of RS-232(3) serial interface cable on front panel;

− Х7 – RJ-45 socket of Ethernet interface for connection of module administrating PC;

− Х8 – socket for supply of power voltage from DCN-16U main board.

Other sockets/connectors on the module board are reserved for service purposes.

1.2.3 DCN-Q4E E1 connection cable

DCN-Q4Е E1 connection cable is intended for connection to DCN-Q4E switching processor module being a part of DCN-16U exchange, up to four DCN-type exchange units. In addition, it enables to connect digital Exchanges (or other products) by digital E1 lines, but the number of DCN exchanges connected decreases to the number of such products. Е1 cable is a passive adapter. Е1 cable is connected to DCN-Q4E switching processor module by means of D-SUB-25А type socket from one end, and form another end its printed circuit

Page 19: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 17/44 [email protected] © Armtel

board with 35/7.5 DIN-rail mountable guides is installed into 19 inch rack. Cable view with overall dimensions is given in the Annex A.

1.2.4 DCN-16U subscribers connection cable

DCN-16U subscribers connection cable is intended for connecting sixteen U-interface lines, four E1 lines, external error message signal and generating А1, А2 failure signals. The cable is connected to DCN-16U Exchange Back panel through C type DIN41612 socket from one end and from another end it is mounted into 19-inch rack (cabinet) by means of printed circuit board with guides for clamping on DIN-rail 35/7.5.

DCN-16U cable is a passive adapter enabling to switch connection cables of subscriber units to DCN-16U Exchange DIN41612С-64М plug with high density of contact configuration.

DCN-16U subscribers connection cable with specifications and overall dimensions is shown in Annex A.

Page 20: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 18/44 armtel.com © Armtel [email protected]

1.3 Subscriber units connected to DCN-16U (with DCN-Q4E)

1.3.1 General information

Loud-speaking intercoms are designed as the subscriber equipment for use in digital intercom and public address/general alarm communication systems. It is powered from centralized power supply with DC voltage of 48 V or by phantom power.

Interface of subscriber unit connection is Uk0. When transmitting audio data both B-channels are engaged enabling to broaden audio transit bandwidth among loud-speakers up to 6.8 kHz.

A subscriber unit generally has a built-in speaker and microphone, digital port and a set of programmable buttons / keys. Programmable button / key functions are assigned during system programming.

Loud-speaking call stations can be desktop and wall-mounted. It is equipped with LF circuit of two-way PA/GA, a set of buttons/keys with indication, may have auxiliary amplifier and control relay. These are loud-speaking intercoms manufactured by Armtel Company such as DW, DWEx, DIS and DIS-TOP call stations.

1.3.2 DCN-2 Exchange / DCN-Q4E switching processor module (to DCN-16U with DCN-Q4E)

The DCN System can include several central exchange interconnected by E1 lines with the extended Armtel DSS protocol. The Armtel DSS protocol provides full-featured integration of exchanges into communication system. As the central exchange of the DCN system can be used DCN-2 Exchange and DCN-Q4E switching processor module. Ones have unified software but different capacities and design.

1.3.2 Digital Exchange (to DCN-16U with DCN-Q4E)

External digital Exchange or other device supporting EDSS1 protocol and E1 interface (G.703/G.704). In this case, the number of DCN-16U is reduced by the number of busy interfaces.

1.3.3 Subscriber units

DIS and DIS-TOP digital desktop call station

DIS and DIS-TOP digital desktop call station have from eight to 32 programmable keys with illumination (DIS) and 42 keys (DIS-TOP). DIS-TOP call station is additionally equipped with 4.3 inch visual TFT-display with LED illumination. Call stations are connected to Uk0 interface using RJ-45 socket. Up to four DIS expansion units with eight to 48 programmable keys can be connected to one DIS, DIS-TOP may have up to ЕС-ТОР expansion units with 42 keys connected.

Page 21: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 19/44 [email protected] © Armtel

DIS call station is manufactured as a desktop version only, DIS-TOP call station can be desktop, wall-mounted and flush-mounted.

Depending on version call stations can be additionally equipped with the external headset or microphone with push-to-talk switch

Loud-speaking call stations

Weather or explosion proof loud-speaking call station of DW or DWEx type accordingly are made wall-mounted and different number of connections depending on number of two-way toggle modules and key modules. Depending on version call stations can be equipped with a keypad, handset, auxiliary amplifier of 25 and 50 W for connection of and external loud-speaker.

Communication line is connected to call station via cable inputs to terminal block assembly.

Call stations unlike console devices are designed for outdoor areas, telecom cabinets and control rooms and can be located outdoors or on sites with high level of noise, electrical interference, humidity, dust content, smoke content, aggressive gas and chemical fumes in the air, within low/high temperature range.

DTS5 and DTS-TOP multifunction desktop digital phone

DTS5 and DTS-TOP multifunction desktop digital phones ties functional area of system phone and DIS and DIS-TOP call stations, and are intended for arranging two-way duplex and simplex communication. DTS5 phone is manufactured as a desktop version, DIS-TOP can be desktop, wall-mounted and flush-mounted.

Apart from digital dialers and hand-set the phones has a set of functional keys, and DIS-TOP phone has 10 programmable keys more, which functions are programmed by operator. Similarly, to call stations the phones may also have DIS and ЕС-ТОР programmable key expansion units connected. When suing the phones in speaker mode built-in speakers and microphone as well as external head-set and microphone can be used.

Phone screen displays system functions, system keys functions, called subscriber details or requests from calling subscribers for connection.

Analogue subsystem modules

Analogue subsystem module has an analogue line LF interface with audio level of 0 dB (0775 V) and eight two-way discrete control lines. These lines can be used as outputs or inputs depending central exchange configuration. In output mode the signal potential (48V) can be supplied from the central exchange to the control lines for managing external devices, for examples, announcement areas. In input mode a signal can be sent from external devices

Page 22: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 20/44 armtel.com © Armtel [email protected]

to the control line to activate any given functions of the central exchange, for example, to start announcement transmission.

The module allows for using analogue call stations incorporated into the communication system. It is also used for interfacing with analogue communication and PA/GA systems of various types, which can be external audio amplifiers, radio stations, radio transmission lines etc.

Page 23: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 21/44 [email protected] © Armtel

2 INTENDED USE

The product is designed for continuous 24-hour a day operations. After commissioning, the product does not require operator intervention, unless:

− maintenance;

− product configuration changes.

Maintenance personnel must be strictly guided by this document in compliance with safety regulations.

The product along with the operational documentation is delivered to the customer in packaged form.

2.1 Operating limits

2.1.1 DCN-16U shall be used under exposure factors and ambient parameters which do not exceed permissible values given in Table 1.

2.1.2 It is forbidden to supply phantom power to products connected to DCN-16U at the same time as main power is supplied to them.

2.1.3 The requirements for operating conditions and the choice of the place of installation given in this document take into account the most typical factors that affect the operation of DCN-16U.

Factors that cannot be predicted, estimated or verified, and which the manufacturer was unable to factor in during development may exist or arise during operation at the operating facility. In the event of such factors, find another operating site where said factors do not exist or do not affect operation of the product.

2.2 Preparation for use − Removing DCN-16U and connection cables from the shipping container.

− Removing DCN-16U and connection cables from the customer package.

− Checking DCN-16U package contents in accordance with attached product passport.

− Visual inspection of the product for damage (cracks, dents, chips, etc.)

− Mount DCN-16U at the operation site in 19-inch rack (cabinet).

− Install and connect DCN-16U (see 2.4).

Page 24: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 22/44 armtel.com © Armtel [email protected]

2.3 Safety precautions During installation and operation of DCN-16U, observe safety precautions laid out in

local regulations on electrical safety.

To avoid electric shock, do not:

− operate the product if its case is not connected to the ground rod;

− operate the product with a damaged power or communication cable;

− the interface cable can be connected and disconnected if the power cable is disconnected.

ATTENTION! NEVER DISMANTLE THE PRODUCT CONNECTED TO MAINS!

Do not use the product in rooms with high humidity of more than 80% or conductive dust.

In order to ensure fire safety, follow the following rules:

− before connecting the product to the power supply, make sure the power and communication cables are properly insulated;

− protect power and communication cables from damage.

ATTENTION: WHEN CONNECTING PHANTOM POWER ADHERENCE TO INSTRUCTIONS OF MANUALS FOR CONNECTED SUBSCRIBER UNITS IS SCTRICTLY REQUIRED! FAILURE TO FOLLOW THE REQUIREMENTS MAY CAUSE

DAMAGE TO THE EXCHANGE AND/OR SUBSCRIBER UNIT!

Page 25: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 23/44 [email protected] © Armtel

2.4 Installation, connection and dismantling 2.4.1 Once DCN-16U installed in 19-inch rack (cabinet) using clamps included in scope

of supply of rack (cabinet) clamping elements, it should be connected to a patch bay in the following order:

− connect a grounding wire, made as per IEC, to earthing terminal on the Back panel of DCN-16U. Protective earthing and as well as grounding arrangement shall meet the IEC requirements. Manufacturer recommendation for grounding wire: cross section of at least 0,5 mm2 with a tab with an outer diameter of at least 7 mm;

Note – Grounding wire is not included in the scope of supply.

− connect the socket of DCN-16U subscriber connection cable to the plug DIN41612С-64М DCN-16U. Clamp cable board in a DIN-rail mounted in the rack (cabinet);

− plug DCN-Q4E E1 cable connector into the module DRB-25FA socket. Clamp cable board in the DIN-rail mounted in the 19-inch rack (for version DCN-16U with pre-installed DCN-Q4E module).

− connect supply voltage wires to three-pin power socket and connect it to DCN-16U Exchange plug with power source being off. Power cable socket with pin numbers is shown in the Annex A.

2.4.2 DCN-16U is connected to DCN central Exchange via E1 line. Connection is carried out by means of UTP-type four-core cable, which is connected to the contacts of XT2 terminal strip of DCN-16U subscribers connection cable from one end, and from another end to the sockets of DCN-2 E1 or DCN-Q4E connection cable. The cable can also be crimped with RJ-45 connector from another end for connecting to RJ-45 socket located on the DCN connection cable board or for connecting to patch bays or network equipment of third-party manufacturers.

2.4.3 Lines of communication with end subscriber units shall be connected to the terminal strips of DCN-16U subscribers connection cable board according to general layout of the communication system.

2.4.3 Connect E1 line of communication with additional DCN-16U Exchanges or DCN-15A analogue inter-face modules to terminal strips of DCN-Q4E E1 connection cable board.

Page 26: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 24/44 armtel.com © Armtel [email protected]

2.4.4 Dismantling:

− Turn off the power source and disconnect the power socket.

− Disconnect the DCN-16U subscriber connection cable from DIN41612С-64М socket and the DCN-Q4E E1 connection cable from the socket DRB-25FA (for version DCN-16U with pre-installed DCN-Q4E module).

− Disconnect the grounding wire.

− Place DCN-16U in consumer packaging.

2.5 Operation

2.5.1 Product On/Off

The product is turned on by connecting the voltage of power source to DCN-16U power socket.

After initialization DCN-16U functions as follows:

− Provides for communication between subscribers according to configuration data;

− Monitors performance of exchange units, digital subscriber units and communication lines;

− Displays check information and error messages.

The product is turned off by disconnecting the voltage of the power source with all indicators on DCN-16U going down.

Page 27: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 25/44 [email protected] © Armtel

2.5.2 Product general performance monitoring routine

Possible states of DCN-16U indicators depending of operation mode are given in Table 3.

Table 3 - Possible states of DCN-16U indicators depending of operation mode

Indicator State Comment

DCN-Q4E module

1..4 E1 line connection status indicators

Out Port is not engaged in configuration

Continuously shine red Port is faulted or there is no connection to it

Red flashing First level (physical) of port is activated

Continuously shine green External exchange is connected

Green flashing DCN-16U is connected

CPU1 indicator (top)

Out Load mode of an operation program

Continuously shine red Load mode of an operation program

Red flashing Load mode of an operation program

Continuously shine green Load mode of an operation program

Green flashing Normal state of CPU

DSP1 indicator (top)

Out Load mode a program or DSP is faulted

Continuously shine red Load mode a program or DSP is faulted

Red flashing Load mode a program or DSP is faulted

Continuously shine green Load mode a program or DSP is faulted

Green flashing Normal state of DSP

DSP2 indicator (bottom)

Out DSP is faulted

Continuously shine red Error exchanging latest an network package

Red flashing Errors in the exchange of network packages

Continuously shine green DSP is efficient

Green flashing DSP is efficient; exchange of network packages

Page 28: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 26/44 armtel.com © Armtel [email protected]

Table 3 - Possible states of DCN-16U (with DCN-Q4E) indicators depending of operation mode (continuous)

Indicator State Comment

DCN-16U

Port indicators (1-16U)

Out Port is not engaged in configuration

Continuously shine red Port is engaged in configuration, but first (physical) protocol level is not activated

Red flashing Port is engaged in configuration, first level is activated, but second protocol level is not set

Continuously shine green The device is in the initial state

Green flashing All protocol levels are set, the device is not in the initial state, for example, conversation state or handset is lifted

1…4 E1 line connection status indicators

Out Line is not engaged

Continuously shine red Line is engaged, but first (physical) protocol level is not activated

Red flashing Line is engaged, first protocol level is activated, but second protocol level is not set

Continuously shine green The device is connected by E1 line

CPU1 indicator (top)

Out Runtime program loading mode

Continuously shine red There is no configuration/no software/ system error on EEPROM memory

Continuously shine green State before system timer startup

Green flashing Normal state, system timer has been started

SYS fuse (48 V) indicator

Continuously shine green Fuse Main is OK

Continuously shine red Fuse Main went

1 fuse status check indicator

Continuously shine green Fuse of phantom power of subscriber units PoU 1-4 connected to 1-4 channels is OK

Continuously shine red Fuse of phantom power of subscriber units PoU 1-4 connected to 1-4 channels went

Page 29: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 27/44 [email protected] © Armtel

Table 3 - Possible states of DCN-16U indicators depending of operation mode (end)

Indicator State Comment

DCN-16U

2 fuse status check indicator

Continuously shine green Fuse of phantom power of subscriber units PoU 5-8 connected to 5-8 channels is OK

Continuously shine red Fuse of phantom power of subscriber units PoU 5-8 connected to 5-8 channels went

3 fuse status check indicator

Continuously shine green Fuse of phantom power of subscriber units PoU 9-12 connected to 9-12 channels is OK

Continuously shine red Fuse of phantom power of subscriber units PoU 9-12 connected to 9-12 channels went

4 fuse status check indicator

Continuously shine green Fuse of phantom power of subscriber units PoU 13-16 connected to 13-16 channels is OK

Continuously shine red Fuse of phantom power of subscriber units PoU 13-16 connected to 13-16 channels went

EXT external source of failure indicator

Continuously shine green Contacts of the XT3 terminal (DCN-16U connection cable) is opened

Continuously shine red Contacts of the XT3 terminal (DCN-16U connection cable) is closed

+ 5 V, + 3 V secondary voltage check indicator

Continuously shine green Secondary supply voltage is generated

Continuously shine red No secondary supply voltage

А1, А2 failure signal indicator

Continuously shine green Exchange operates properly

Continuously shine red Failure in Exchange operation

Page 30: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 28/44 armtel.com © Armtel [email protected]

2.5.3 Troubleshooting

Possible problems and their solutions are given in Table 4.

Table 4 – Possible problems and their solutions

Problem Possible cause Solution

DCN-Q4E module

When the power is in DCN-Q4E indicators don’t glow

No power voltage is supplied to DCN-Q4E

Check power circuit and connect to the power source

Indicator one of the Е1 ports (1-4) flashes red

First level (physical) of port is activated, but second protocol level is not set

Check configuration and correct connection by E1 line

DSP1 indicator outs, continuously shines red or green, flashes red.

DSP is faulted Check the boards’ connection quality into the socket or change the board

DCN-16U

When the system power in on DCN-16U indicators don’t glow

No power voltage is supplied to DCN-16U

Check power circuit and DCN-16U power socket operability

At power on, SYS fuse (48 V) indicator is red DCN-16U main fuse went

Find the cause, remove the cause of trouble and change main fuse of DCN-16U

At power on, 1 fuse indicator is red

Fuse of phantom power supply of subscriber units connected to 1-4 channels went

Find the cause, remove the cause of trouble and change fuse of phantom power

At power on, 2 fuse indicator is red

Fuse of phantom power supply of subscriber units connected to 5-8 channels went

Find the cause, remove the cause of trouble and change fuse of phantom power

At power on, 3 fuse indicator is red

Fuse of phantom power supply of subscriber units connected to 9-12 channels went

Find the cause, remove the cause of trouble and change fuse of phantom power

At power on, 4 fuse indicator is red

Fuse of phantom power supply of subscriber units connected to 13-15 channels went

Find the cause, remove the cause of trouble and change fuse of phantom power

At startup an indicator of one of the ports (1-16U) doesn’t glow

Port configuration is not set. Port is not engaged in the configuration

Set port configuration using con-figuration manager

Page 31: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 29/44 [email protected] © Armtel

Table 4 – Possible problems and their solutions (end)

Problem Possible cause Solution

At startup an indicator of one of the ports (1-16U) is red

Port is off or broken Enable or repair port

Subscriber unit connection cable is broken

Change subscriber unit connection cable

At startup, CPU 1 doesn’t glow

Runtime program loading mode Turn DCN-16U off and on

CPU didn’t start

At startup, CPU 1 is red Software is not loaded Load DCN-16U configuration

data or software and initialize its operation System error occurred

At startup, Ext indicator is red

Input contacts of external failure source are closed

Find the cause, remove the cause of trouble

At startup, A1 indicator is red

No +5V secondary voltage

Find the cause, remove the cause of trouble

No +3,3V secondary voltage

CPU or Software (by WatchDog) loss of function

Hardware bags, produced by CPU (for example, DELIC is out-of-order)

При включении индикатор А2 светится красным

One or more of fuse of phantom power subscriber units PoU went

Find the cause, remove the cause of trouble External failure source’ input

contacts are closed

Software bags from CPU

При включении индикатор контроля вторичного питания + 5 В, +3 В светится красным

No secondary voltage DCN-16U needs to be repaired

At startup, Е1 line indicator is red

No connection to DCN-2 by Е1 line

Connect DCN-16U ty DCN-2 by Е1 line

Page 32: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 30/44 armtel.com © Armtel [email protected]

3 MAINTENANCE

Maintenance shall be carried out to ensure the module fault-free performance and instant readiness for use. Maintenance is carried out once a year without the product being disconnected.

During maintenance, observe safety precautions according to general and local “Occupation safety rules when operating electrical installation”.

Maintenance includes as follows:

− Inspect DCN-16U enclosure visually, no mechanical damages (cracks, dents, etc.) on the enclosure, cover or controls are allowed.

− Remove dust and dirt from product surface.

− Check product mounting in the cabinet (rack) and external sockets clampings.

− Inspect cables attaching to DCN-16U (it should not be squeezed and damaged).

− Check reliability of connection to cable connectors – cables should not be tensed.

− Check condition of switching point, protection and signaling elements.

− Clean, if necessary, terminal strips and the board from dust by air flow (dirt cleaned by air flushing shall not get into other units) with DCN-16U enclosure cover being removed.

ATTENTION: DCN-16U COVER REMOVAL AND AIR FLUSHING ARE ONLY ALLOWED IF DCN-16U ECHANGE IS DEENERGIZED!

Approximate maintenance time is 1 hour.

All actions carried out on the product, defects found and negative findings of the maintenance shall be recorded in the special logbooks.

Page 33: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 31/44 [email protected] © Armtel

4 REPAIR

No scheduled repair work is provided for DCN-16U. Unscheduled repair shall be performed by manufacturer at the request of the User.

The place, time, procedure and cost of the work shall be agreed with the manufacturer in advance.

Page 34: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 32/44 armtel.com © Armtel [email protected]

5 STORAGE

DCN-16U storage conditions are as follows: in item-specific manufacturer’s packaging, heated and ventilated storages or warehouses with air-conditioning with a range of temperature from plus 5 to plus 40 °С.

No aggressive contaminations (acid, alkali fumes) with air shall be in the product storage premises.

Page 35: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 33/44 [email protected] © Armtel

6 TRANSPORTATION

The product shall be transported in customer package as a packaging unit by road, river, railway and air transport (expect unsealed compartments), with compliance with the following conditions:

− absence of direct ingress of atmospheric precipitation, water splashes, solar UV radiation, dust, sand, aerosols;

− the shipping container on the shipping vehicle is fastened to avoid falling and collision.

At the same time, transportation of the DCN-16U connection cable and DCN-Q4E E1 connection cable installed in the rack on a DIN-rai is allowed as part of the rack. Measures must be taken to secure the DCN-16 connection cable and the D-SUB-25A connector of the DCN-Q4E E1 connection cable to prevent their free movement.

In case transportation the DCN-16U connection cable and the DCN-Q4E E1 connection cable in the rack, DCN-16U is placed into the customer package without cables.

ATTENTION: THE TRANSPORTATION OF THE DCN-16U EXCHANGE MOUNTED INTO THE COMMUNICATION RACK WITHOUT ADDITIONAL MOUNTING ELEMENTS FOR STRONG FIXING IS STRICTLY FORBIDDEN! THIS MAY CAUSE

DAMAGE TO OR DESTRUCTION OF EQUIPMENT.

Page 36: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 34/44 armtel.com © Armtel [email protected]

7 DISPOSAL

The product is not subject to disposal along with daily waste and shall be delivered to a special electronic product disposal facility. Operator is responsible for product disposal.

Page 37: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 35/44 [email protected] © Armtel

ANNEX А (REFERENCE) СONNECTING OPTIONAL EQUIPMENT AND POWER SUPPLY

А.1 DCN-Q4E E1 connection cable DCN-Q4Е E1 connection cable with overall dimensions is illustrated at Figure А.1. Cable

weight is (0,31 ± 0,05) kg.

Figure А.1 – DCN-Q4Е Е1 connection cable

Two types of sockets may be used for connecting DCN-Q4Е module by E1 lines to the cable. Connection is carried out through terminal boxes by 4-ware line or through RJ-45 sockets (Table А.1).

Table А.1 – Connecting DCN-Q4E module by Е1 lines

E1 port No Identification in Software Terminal box RJ-45 Socket

1 Module 0 XS1 XS7

2 Module 1 XS2 XS9

3 Module 2 XS3 XS6

4 Module 3 XS4 XS8

DCN-Q4Е (RJ-45 – RJ-45) E1 connection line X1 terminal box and RJ-45 pin assignment are given in the Table А.2.

Page 38: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 36/44 armtel.com © Armtel [email protected]

Table А.2 – X1 terminal box and RJ-45 pin assignment

RJ-45 Socket contact Terminal box contact Signal Assignment

3 2 Tx 1 Transmission 1

4 1 Rx 1 Reception 1

5 3 Rx 2 Reception 2

6 4 Tx 2 Transmission 2

ХS1 terminal box contact numbers are illustrated at Figure А.1. Contacts of ХS2, ХS3, ХS4 terminal strips are located in the same way.

View of any of four RJ-45 Sockets of DCN-Q4Е E1 connection cable with contact numbering is illustrated at Figure А.2.

Figure А.2 – RJ-45 Socket

ХS5 Socket is designed for failure signals transmission. Normally-opened, normally-closed and K1 relay central contact are assigned to socket pins.

ХS5 pin assignment is given in Table А.3.

Table А.3 – XS5 pin assignment

Contact No Assignment Contact No Assignment Contact No Assignment

1 n /с 2 сом 3 n /о

Relay K1 is triggered when an internal alarm occurs under the following conditions:

− CPU is faulted;

− DSP is faulted;

− No DSP communication with CPU;

Page 39: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 37/44 [email protected] © Armtel

− The subscriber unit is not available for DCN-Q4E (line break, unit is faulted/out);

− DCN-16U, which connected by E1 line to DCN-Q4E, is not available (line break, DCN-16U is faulted/out);

− Other devices, which connected by E1 line to DCN-Q4E, is not available (line break, device is faulted/out).

Page 40: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 38/44 armtel.com © Armtel [email protected]

А.2 DCN-16U digital subscribers connection cable DCN-16U subscriber connection cable with overall dimensions is given in

the Figure A.3. Cable weight is (0,6 ± 0,05) kg.

1 – ХТ1 terminal ship for connection of subscriber units; 2 – ХТ2 terminal ship for connection of four E1 lines (E1 line 4 used by default); 3 – ХТ3 terminal ship for connection signal of external failure source “Ext” (dry contact); 4 – ХТ4 terminal ship for А1 failure and

Sys signals generation; 5 – ХТ5 terminal ship for A2 failure signal generation.

Figure А.3 – DCN-16U subscribers connection cable

DCN-16U subscriber connection cable is connected to DCN-16U exchange back panel through C type DIN41612 socket from one end and from another end it is mounted into 19-inch rack (cabinet) by means of printed circuit board with guides for clamping on DIN-rail 35/7.5.

Terminal assignment of ХT1 is given in the Table А.1.

Page 41: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 39/44 [email protected] © Armtel

Table A.1 – Terminal assignment of XT1

Contact Assignment Contact Assignment

Ua1+ Subscriber interface line 1

Ua9+ Subscriber interface line 9

Ub1- Ub9-

Ua2+ Subscriber interface line 2

Ua10+ Subscriber interface line 10

Ub2- Ub10-

Ua3+ Subscriber interface line 3

Ua11+ Subscriber interface line 11

Ub3- Ub11-

Ua4+ Subscriber interface line 4

Ua12+ Subscriber interface line 12

Ub4- Ub12-

Ua5+ Subscriber interface line 5

Ua13+ Subscriber interface line 13

Ub5- Ub13-

Ua6+ Subscriber interface line 6

Ua14+ Subscriber interface line 14

Ub6- Ub14-

Ua7+ Subscriber interface line 7

Ua15+ Subscriber interface line 15

Ub7- Ub15-

Ua8+ Subscriber interface line 8

Ua16+ Subscriber interface line 16

Ub8- Ub16-

Page 42: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 40/44 armtel.com © Armtel [email protected]

Terminal assignment of ХT2 is given in the Table A.2.

Table A.2 – Terminal assignment of XT2

Contact Assignment Contact Assignment

TXb1 First Е1 line, transmission

TXb3 Third Е1 line, transmission

TXa1 TXa3

RXb1 First Е1 line, reception

RXb3 Third Е1 line, reception

RXa1 RXa3

TXb2 Second Е1 line, transmission

TXb4 Fourth Е1 line, transmission

TXa2 TXa4

RXb2 Second Е1 line, reception

RXb4 Fourth Е1 line, reception

RXa2 RXa4

Terminal assignment of ХT3 is given in the Table A.3.

Table A.3 - Terminal assignment of XT3

Contact Assignment

1 External failure source signal output (dry contact)

2

Terminal assignment of XT4 is given in the Table A.4.

Table A.4 – Terminal assignment of XT4

Contact Assignment

1 n/с

2 сом

3 n/о Terminal assignment of ХT5 is given in the Table A.5.

Table A.5 – Terminal assignment of XT5

Contact Assignment

1 n /с

2 сом

3 n /о

Page 43: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 41/44 [email protected] © Armtel

А.3 Connection to power supply

First the power cable connects to the “-48 0V GND” socket of DCN-16U (refer to Figure 5), after – to a power source.

Power cable socket with pin numbers is shown in the Figure A.4.

1 – -48 V from power source; 2 – 0 V from power source; 3 – GND for phantom power supply

Figure А.4 – DCN-16U power cable socket

Page 44: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 42/44 armtel.com © Armtel [email protected]

А.4 Phantom power supply

In order to supply phantom power to subscriber units it is necessary to supply 0V power to contact 3 “GND” of power socket (refer to Figure A.4) and place the jumpers on the contact pairs that corresponds to subscriber units (refer to Figure A.5)

ATTENTION: WHEN CONNECTING PHANTOM POWER ADHERENCE TO INSTRUCTIONS OF MANUALS FOR CONNECTED SUBSCRIBER UNITS IS SCTRICTLY REQUIRED! FAILURE TO FOLLOW THE REQUIREMENTS MAY CAUSE DAMAGE TO

THE EXCHANGE AND/OR SUBSCRIBER UNIT!

1 – DCN-16U power cable socket; 2 – contact pairs for installation of jumpers 1…16 Ub-; 3 – contact pairs for installation of jampers 1…16 Uа+.

Note - 16 Ua+ and 16Ua- contact pairs not used.

Figure А.5 – Contact pairs for installation of phantom power supply jumpers

Page 45: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E)

User Manual

armtel.com page 43/44 [email protected] © Armtel

NOTES

Page 46: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

DCN-16U EXCHANGE (BASIC VERSION, VERSION WITH PRE-INSTALLED SWITCHING MODULE DCN-Q4E) User Manual

page 44/44 armtel.com © Armtel [email protected]

Page 47: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

armtel.com [email protected] © Armtel

Page 48: DCN-16U Exchange (basic version, version with pre-installed ......DCN-16U Exchange of ARMT.665200.00101 version has pre-installed switching - processor module DCN -Q4E (4 хЕ 1) ARMT.665200.010,

ARMTEL LLCTel./fax: +7 (812) 703-41-11

www.armtel.com | [email protected] and physical address: 12 building 1, Zaporozhskaya street,

office 1/2, Saint Petersburg, 192012, Russia

TECHNICAL SUPPORT

8-800-500-90-17 (for calls from Russian Federation)+7-812-633-04-02 (for international calls)

[email protected]

MORE INFORMATION ABOUT PRODUCT ON OFFICIAL SITE

2018


Recommended