+ All Categories
Home > Documents > DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme...

DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme...

Date post: 28-May-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
23
DE-FE-0029093: Heat Integration Optimization and Dynamic Modeling Investigation for Advancing the Coal Direct Chemical Looping Process NETL Project Review Meeting | August 15 th , 2018 Dikai Xu Andrew Tong (PI), L.-S. Fan (Co-PI) Department of Chemical and Biomolecular Engineering THE OHIO STATE UNIVERSITY
Transcript
Page 1: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

DE-FE-0029093: Heat Integration Optimization and Dynamic

Modeling Investigation for Advancing the Coal Direct Chemical

Looping Process

NETL Project Review Meeting | August 15th, 2018

Dikai Xu

Andrew Tong (PI), L.-S. Fan (Co-PI)

Department of Chemical and Biomolecular Engineering

THE OHIO STATE UNIVERSITY

Page 2: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Main reactions:

Reducer: Coal + Fe2O3 → Fe/FeO + CO2 + H2O

Oxidizer: Air + Fe/FeO → Fe2O3 + Spent Air

Overall: Coal + Air → CO2 + H2O + Spent Air

OSU Coal Direct Chemical Looping Process

CDCL Plant

Coal Feed, kg/h 205,358

CO2 Capture Efficiency, % 96.5

Net Power Output, MWe 550

Net Plant HHV Efficiency, % 35.6

Cost of Electricity, $/MWh 102.67

Increase in Cost of Electricity, % 26.8

Reducer

Combustor

Pump

Coal Prep.Coal

CO2

compressor

Particulate Removal

FGD Stack

CO2

Sequestration

LPIPHP

Air

Fe2O3

Cooling Tower

ID Fan

Water

ID Fan

H2O

CO2+H2O

Enhancer Gas Recycle Fan

Electricity

Carrier Particle Makeup (Fe2O3)

Fly Ash and Carrier Particle Fines

FGD

Spent Air

Steam

WaterSteam Cycle

FeO/Fe

Existing equipment for repowering case

Existing equipment for repowering case

Existing equipment for repowering case

Page 3: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

OSU Chemical Looping Evolution

2.5 kWth Reducer 25 kWth CDCL UnitTGA

Oxygen Carrier Reactivity (TGA)

Reduction Kinetics and Mechanism

Fixed Bed

Moving Bed Model and Results

Integrated Design

1993 2013 to present

Laboratory Studies Bench Testing Sub-Pilot Testing Pilot Plant Demonstration

250 kWth CDCL Unit

Reduce Gas Profile

Sulfur Balance

Page 4: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

OSU Coal Direct Chemical Looping Process 200-Hour Continuous Operation at 25kWth Sub-pilot Scale

Reducer Carbon Conversion Profile

Reducer Gas Concentration Profile

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

10 60 110

Carb

on

Co

nv

ers

ion

(%

)

Time of reaction (min)

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

0.5

0

2

4

6

8

10

2 4 6 8 10 12 14 16 18

Co

nc

en

tra

tio

n (

%)

CO

, C

H4

, C

O2

Co

nc

en

tra

tio

n (

%)

O2

Time (min)

CO2

O2

CO

CH4

Combustor Gas Concentration Profile

CH4

COCO2

O2

Sample Data: PRB Process Performance

• Continuous steady carbon conversion from reducer throughout all solid fuel loading (5-25kWth)

• <0.25% CO and CH4 in reducer outlet = full fuel conversion to CO2/H2O

• <0.1% CO, CO2, and CH4 in combustor = negligible carbon carry over, nearly 100% carbon capture

Page 5: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

CDCL Development Pathway

HEN and Dynamic Model

2010 2025

Page 6: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Scale Up Plan

Lab

TestingLarge Pilot

(10 MWe) Commercial Offering

Time

Small Pilot (250th)

Bench (25 kWth)

Modular Reactor Design

• Chemical looping inherent low capital cost technology

• Reduce risks for large scale-up

High Risk

100x

Page 7: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Scale Up Plan

Lab

TestingLarge Pilot

(10 MWe) Commercial Offering

Time

Small Pilot (250th)

Bench (25 kWth)

Modular Reactor Design

• Chemical looping inherent low capital cost technology

• Reduce risks for large scale-up

High Risk

100x

Challenge: Integrating with Dover Site

Page 8: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Project Objective

Reduce risks in the CDCL technology development to enable scale-up and eventual commercialization

1. Enable Commercialization

2. Enable Scale-Up

1 2 3 4 1 2 3 4 1 2 3 4

1 Project Management and Planning

Quarterly Reports

Final Report Preparation

2 Chemical Looping Combustor Simulation

2.1 Bench Unit Combustor Apparatus Setup

2.2 Oxygen Kinetic Model Development and Verification

2.3 Modeling Scheme Including Coupling of Hydrodynamics, Heat Transfer and Reaction

2.4 Pilot and Commercial Scale Combustor Analysis

Milestone 2.1: Combustor Apparatus Ready for Operation

Milestone 2.2: Oxygen Carrier Kinetic Model Developed

Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed

3 Heat Exchanger Network Integration and Optimization

3.1 CDCL Static Model Development

3.2 HEN Design with Steam Cycle

3.3 HEN Optimization

3.4 Heat Exchanger Sizing and CDCL 550 MWe Cost Analysis Update

Decision Point 1: Integrated CDCL Systems Analysis Model Developed

Milestone 3.2: HEN Design Developed for Cost Analysis

4 Dynamic Modeling of Integrated CDCL-Steam Cycle System

4.1 CDCL Process Model Development

4.2 Steam Cycle Model Development

4.3 Integrated System Model Development

4.4 System Operation Simulation

Milestone 4.1: Dynamic Model for 10 MWe CDCL Reactor Developed

Milestone 4.2: Dynamic Model for 10 MWe Steam Cycle Developed

Decision Point 2: Integrated Dynamic Model for 10 MWe CDCL Process DevelopedDecision Point 2: Integrated Dynamic Model for 10 MWe CDCL Process Developed

BP2Tasks/Milestones

BP1 BP3

Page 9: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

• CDCL Combustor Model• USCM Kinetic Model

• MFiX CFD Model

• Design and Analysis of 10MWePilot and 550MWe Commercial Plant• Lateral Transport & Mixing

• Oxygen Carrier Conversion

• Heat Transfer

USCM Kinetic Model MFIX CFD Model

Combustor Performance Model

Task 2: Combustor Simulation

Page 10: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 2: Combustor Simulation

URSM for Fully-reduced Particle URSM for Partially-reduced Particle

• USCM Kinetic Model• Extended model to consider

partially-reduced particle

• Used TGA experiments to determine rate constants

• Model tested at different temperature and O2 concentration

Page 11: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 2: Combustor Simulation

• USCM Kinetic Model• Extended model to consider

partially-reduced particle

• Used TGA experiments to determine rate constants

• Model tested at different temperature and O2 concentration

800oC, Fully-reduced Particle

800oC, Partially-reduced Particle 1000oC, Partially-reduced Particle

Page 12: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 2 Hydrodynamic Modeling

• MFiX CFD Model of Combustor• Based on MFiX Two Fluid Model

• Study the effect of reactor geometry and in-bed heat exchanger on combustor performance

• Validation by cold flow model with heat exchanger tubes

Page 13: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 2 Hydrodynamic Modeling

• MFiX CFD Model of Combustor• Based on MFiX Two Fluid Model

• Study the effect of reactor geometry and in-bed heat exchanger on combustor performance

• Validation by cold flow model with heat exchanger tubes

Page 14: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 2 Hydrodynamic Modeling

• MFiX CFD Model of Combustor• Based on MFiX Two Fluid Model

• Study the effect of reactor geometry and in-bed heat exchanger on combustor performance

• Validation by cold flow model with heat exchanger tubes

Page 15: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 3: HEN Integration and Optimization

Reducer

Combustor

Pump

Coal Prep.Coal

CO2

compressor

Particulate Removal

FGD Stack

CO2

Sequestration

LPIPHP

Air

Fe2O3

Cooling Tower

ID Fan

Water

ID Fan

H2O

CO2+H2O

Enhancer Gas Recycle Fan

Electricity

Carrier Particle Makeup (Fe2O3)

Fly Ash and Carrier Particle Fines

FGD

Spent Air

Steam

WaterSteam Cycle

FeO/Fe

Existing equipment for repowering case

Existing equipment for repowering case

Existing equipment for repowering case

• CDCL Process Simulation in ASPEN Plus• 550 MWe plant• In-bed heat exchanger• Industrial relevant constrains

• Integration with Steam-Cycle• Multiple heat exchanging surfaces

• HEN Optimization

• Cost Estimation

Page 16: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 3: HEN Integration and Optimization

• CDCL Process Simulation• In-bed heat exchanger

• Industrial relevant constrains

• Integration with Steam-Cycle• Multiple heat exchanging surfaces

• HEN Optimization

• Cost Estimation

Page 17: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 3: HEN Integration and Optimization

CDCL Unit

CO2 Capture

Heat Recovery

Power Generation

Page 18: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 3: HEN Integration and Optimization

• Simulation settings• Coal: Illinois #6• Steam cycle• Supercritical cycle• 24.1 MPa/593 oC/593 oC• Adapted based on prior studies from B&W

• Preliminary results of HHV efficiency• Baseline: 32.5%• CDCL process: 37.6%

CDCL Preliminary Design

Total Gross Power, MWe 643

Total Auxiliaries, MWe 93

Net Power, MWe 550

HHV Thermal Input, MWt 1462

HHV Net Plant Efficiency (%) 37.6

As- Received Coal Feed, kg/hr 194,110

Page 19: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 4: Dynamic Modeling of Integrated Power Plant

CDCL Dynamics Steam Cycle Dynamics

Integrated Dynamic Model

2.5 kWt 25 kWt 250 kWt 4 x 2.5 MWe 1 x 70 MWe

Critical Dimension Scale up Factor:

1x

Critical Dimension Scale up Factor:

4x

Critical Dimension Scale up Factor:

6x

Critical Dimension Scale up Factor:

2.3 x

Critical Dimension Scale up Factor:

2.8 x

Reducer reactor Critical Dimension:

1.5 in

Reducer reactor Coal distribution

Distance:6 in

Reducer reactor Coal distribution

Distance :3 ft

Reducer reactor Coal distribution

Distance :7 ft

Reducer reactor Coal distribution

Distance:20 ft

Coal

• Dynamic Modeling in ProTRAX

• 10 MWe CDCL pilot plant• Preliminary design from DE-

FE0027654

• Existing 20 MWe steam cycle at Dover, OH• Based on data obtained from Dover

Light & Power

• Startup and operation simulation

Page 20: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 4: Dynamic Modeling of Integrated Power Plant

B&W OSU B&W

Steam cycle model CDCL model Steam cycle model

Steam Side Gas Side Steam Side

COMBUSTOR

→ →

← ←

Waterwall ← ← FSH

→ →

← ←

GB

→ →

Page 21: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Task 4: Dynamic Modeling of Integrated Power Plant

• Dynamic Model for CDCL• Mass and Energy Balance• Hydrodynamic

Correlation• Chemical Reactions

• Dynamic Model for Steam Cycle• Obtained steam cycle

design and parameter from Dover Light & Power

Page 22: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Conclusion

• Combustor performance model will be developed in this project to support HEN integration and system dynamic studies

• HEN integration and optimization will be performed to enable the commercialization of the CDCL process

• Dynamic modeling will be performed to enable the scale-up of the CDCL process

• Kinetic model for oxygen carrier oxidation in CDCL combustor is developed to simulate the oxidation of fully- and partially- reduced oxygen carrier particles

• MFiX CFD model is being developed to study the effect of bed geometry and in-bed heat exchanger on fluidization properties of the combustor reactor

• ASPEN Plus model of 550 MWe integrated CDCL-steam cycle plant is developed for HEN optimization

• ProTRAX dynamic model is being developed for 10 MWe CDCL pilot plant at Dover

Page 23: DE-FE-0029093: Heat Integration Optimization and Dynamic ... · Milestone 2.3: Modeling Scheme Coupling of Hydrodynamics, Heat Transfer and Reaction Developed 3 Heat Exchanger Network

Thank You

Disclaimer

This presentation was prepared as an account of work sponsored by an agency of the United States Government. Neither the United

States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any

legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process

disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product,

process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement,

recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed

herein do not necessarily state or reflect those of the United States Government or any agency thereof.


Recommended