Product Bulletin forZ-Wave Plus Technology Switches and Dimmers
Decora Smart with Z-Wave Technology
Z-Wave Plus Product FamilyThe Decora Smart with Z-Wave Plus Technology family of products feature five devices including in-wall dimmers, a switch, and plug-in modules for appliances and lamps. The family of solutions utilizes the latest generation of technology for advanced wireless lighting control products.
Most devices support a wide range of load types including LED, CFL, and incandescent amongst others at various wattages with multi-way capability for large rooms or hallways. The products are Z-Wave Plus certified, ensuring increased communication range, network wide inclusion, and over the air updates.
The highly advanced design features two-way feedback, is scene capable, and is supported by security systems, hubs, and gateways that are Z-Wave enabled which provide remote access and scheduling.
In-Wall Dimmers and switches boast the new Leviton design with true rocker action, pressing the top to turn on and the bottom to turn off. For the 600W and 1000W dimmers, the dim/brighten bar is conveniently located along the right hand side of the paddle, ensuring ease of use with the state-of-the-art device. Vanishing LEDs to the left of the Dimmer paddle show current and target light level with real-time feedback. To meet any decor, color change kits are available in white, ivory, light almond, gray, black, and brown. For the most professional and cleanest installation, pair the device with an optional Leviton screwless wallplate.
Features and Benefits Gloss finish complements any décor Compatible with Leviton vizia rf + Remotes available for 3-way/multi-location control Limited 5-year warranty
Z-WAVE PLUS CERTIFICATION Increased communication range Network Wide Inclusion Support for beaming and secure commands Over The Air (OTA) updates 500-Series Chipset
SINGLE POLE WIRING DIAGRAM THREE-WAY WIRING DIAGRAM
DZ1KD 1000W Dimmer with Z-Wave Technology
IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the Common (Line or Load) in both the dimmer wall box and remote wall box.
For non-standard wiring applications, referto Wire Connector and Conductor Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #182 - #12 w/ 1 or 2 #16 or #181 - #14 w/ 1 to 4 #16 or #182 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.COMBINATION CHART
• Pull off pre-cut insulation from dimmer leads.• Make sure that the ends of the wires from the wall box are straight
(cut if necessary).• Remove insulation from each wire in the wall box as shown.• For Single-Pole Application, go to Step 4a.• For 3-Way Matching Remote (w/LEDs) Application, go to Step 4b.
Step 4b
TOOLS NEEDED TO INSTALL YOUR DIMMERSlotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
MULTI-DEVICE APPLICATIONIn multi-dimmer installations, the reduction of the dimmer’s capacity may be required. Refer to the chart for maximum load per dimmer. NOTE: No derating is required for LED or CFL bulb applications.
If installing the device in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows:
INSTALLING DIMMER BY ITSELF OR WITH OTHER DEVICES
Changing the color of your Dimmer:Your device may include color options. To change color of the face proceed as follows:
1
2
Insert top tabs and press in bottom tabs to attach
Push in sides at bottom tabs and pull outward to release
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
Step 1
Step 2 Identifying your wiring application (most common):NOTE: If the wiring in your wall box does not resemble any of these configurations, consult an electrician.
2
43
1
Single Pole
1. Line (Hot)2. Neutral3. Ground4. Load
3-Way
1. Line or Load(see important instruction)2. Neutral3. Ground4. First Traveler – note color5. Second Traveler – note color
2
4
1
5
3
Cut (if necessary)
5/8" (1.6 cm) Strip Gage
(measure bare wire here)
Preparing and connecting wires:Pull off pre-cut insulation from dimmer leads. Make sure that the ends of the wires from the wall box are straight (cut if necessary). Remove insulation from each wire in the wall box as shown:
Step 3
Dimmer
InsulatingLabel
Black
Load
Hot (Black)Black
Line120 VAC,
60Hz
Neutral (White)
Red
Yellow/Red
White
White
GreenGround
White
Red
Green
Black 1
4
2
3
Insulating label:This wire is used in 3-way installations only.For single pole installations, do not remove insulating label.
Yellow/Red
Single Pole Wiring Application: Step 4a
MAXIMUM BULB WATTAGELow-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency of the transformer in the low-voltage lighting system. Transformer efficiencies will vary from different manufacturers; consider 80% efficient as average. Use the chart to determine maximum bulb wattage for typical transformer efficiency ratings.
MAXIMUM BULB WATTAGEMark 10® Powerline dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency of the Mark 10® Powerline ballast. The following table shows the maximum number of ballasts that can be connected to a single dimmer for different Mark 10® Powerline ballasts. Also note that the table shows maximum ballasts for multi-gang installations.
Lutron Tu-Wire®:To determine total ballast load, add the line current found on the ballast label for all ballasts in the circuit. This will indicate the total load for the control.
Remove all inner side sections
Do not remove outer side sections
Bend back and forth to remove side section
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than 2 Devices
700W
700VA
Two Devices
800W
800VA
Single
1000W
1000VA
Load
Incand
Mag LV
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
More than 2 Gang
560W
Rating
1000VA
Single
800W
Two Gang
640W
INTRODUCTION
Leviton’s Decora SmartTM Z-Wave® Dimmers are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. In a Z-Wave® network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. This dimmer is compatible with any Z-Wave® enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave® logo.WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH, DO NOT USE the remote for the control of high power heating appliances such as portable heaters. There can be some unexpected consequences if not used with care. For example, an empty coffee pot can be remotely turned on. If that should happen, your coffee pot could be damaged from overheating. If an electric heater is turned on by remote control while clothing is draped over it, a fire could result. This device will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury-vapor, sodium vapor and metal halide lamps.Decora® Smart Devices are ideal for living rooms, bedrooms, kitchens, dining rooms, home offices, outdoor lighting or anywhere full control of lighting is desired.
• Z-Wave Plus™ Certification - Increased communication range - Network Wide Inclusion - Support for beaming and secure commands - Over The Air (OTA) updates• Compatible with Leviton Vizia RF+ systems• Soft fade ON/OFF• ON/OFF LED and Brightness level LED • Three way communication • Ease of installation - No new wiring
FEATURES
WIRING DIMMER:Connect wires per WIRING DIAGRAM as follows:WARNING: CONNECT A MAGNETIC LOW-VOLTAGE DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC LOW-VOLTAGE TRANSFORMER.NOTE: The DZ1KD dimmer requires a Neutral wire connection.• Green or bare copper wire in wall box to Green dimmer lead.• Line Hot wall box wire to Black dimmer lead.• Load wall box wire to Red dimmer lead.• Line Neutral wall box wire to White dimmer lead.• Yellow/Red dimmer lead should have Red insulation label affixed. NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, use
electrical tape to cover.• Proceed to Step 5.
Cat. No. DZ1KD, 120V, For use with Advance Transformer 120V Mark 10® Powerline Electronic Ballasts
Max. # Ballasts/Dimmer for Multi-gang
Advance Mark 10®
Powerline Part No.
LampSingle Gang
Two Ganged
More than 2 Gang
REZ-2Q18-M2-LD
REZ-1T32
REZ-2Q26
REZ-1T32
REZ-1T42
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-1T32
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-2Q18-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2T42-M3-BS CFTR32W/GX24Q 13 10 8
CFTR32W/GX24Q 26 20 16
CFTR32W/GX24Q 26 20 16
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 32 25 20
CFTR26W/GX24Q 32 25 20
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 46 37 30
CFTR18W/GX24Q 46 37 30
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ18W/G24Q 23 18 15
CFQ18W/G24Q 46 37 30
CFQ18W/G24Q 46 37 30
CFM42W/GX24Q 20 16 13
CFM32W/GX24Q 26 20 16
CFM26W/GX24Q 17 13 11
CFM26W/GX24Q 32 25 20
151823CFM18W/GX24Q
WARNINGS AND CAUTIONS• Dimmer may feel warm to the touch during normal operation.• When magnetic low voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible transformer failure due to over
current, use a transformer that incorporates thermal protection or a fuse at the primary windings.• Recommended minimum wall box depth is 2-3/4".• Use this device with copper or copper clad wire only.• Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen fixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.• DO NOT mix bulb types when multiple bulbs are used with one dimmer. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance dimmer performance.• Leviton recommends Z-Wave® technology in residential installations up to 7,500 sq/ft. Metal junction boxes may adversely affect network coverage. Communication is designed to pass
through interior materials, exterior materials are designed to reflect RF energy and may prevent communication to detached buildings.• Z-Wave® networking technology is designed for distributed communication. Large clustering of communicating devices in a centralized location (ie. a closet) is not recommended.
WIRING DIMMER (wall box with load connection):Connect wires per WIRING DIAGRAM as follows:NOTE: The DZ1KD dimmer must be installed in a wall box that has a Load connection and a Neutral connection.• Green or bare copper wire in wall box to Green dimmer lead.• Load wall box wire identified (tagged) when removing old switch to
Red dimmer lead.• First Traveler Line Hot to Black dimmer lead.• Remove Red insulating label from Yellow/Red dimmer lead.• Second Traveler wall box wire (note color as above) to
Yellow/Red dimmer lead. This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to White dimmer lead.
WIRING MATCHING REMOTE (wall box with line hot connection):Connect wires per WIRING DIAGRAM as follows:NOTE: The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown.NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).• Green or bare copper wire in wall box to Green terminal screw.• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to Remote terminal marked "BK".• Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote must go to Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked "WH".• Proceed to Step 5.
Hot (Black)
Neutral (White)
DimmerMatching Remote (w/LEDs)
YL/RD
Red
Yellow/Red
WH BKBlack
Black
White
Line120VAC, 60Hz
GreenGround
GreenGround
WhiteLoad
3-Way Wiring with DD00R Matching Remote (w/LEDs) Application:
Matching Remote DimmerAdditional Neutral Wire
White
Red
Green
Black
1
2
3
Yellow/Red
4
5
1
2
3
4
5
WARNINGS AND CAUTIONS• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!• TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor, or a transformer operated appliance. • To be installed and/or used in accordance with electrical codes and regulations.• If you are unsure about any part of these instructions, consult an electrician.• Use with magnetic low voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers.• Use ONLY with the appropriate Advance Transformer 120V Mark 10® Powerline or Lutron Tu-Wire® electronic ballasts for controlling the specific fluorescent lamps in Fluorescent Mode.• When retrofitting Mark 10® Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start sockets to allow proper
dimmer operation and prevent damage to the dimmer ballast. Refer to the instructions provided with the ballast.• The Decora® DZ1KD dimmer is not compatible with standard 3-way or 4-way switches. It must be used with up to 4 Decora® Digital DD00R-DL remotes for multi-location dimming.• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.• Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
• Reorient or relocate the receiving Antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.
RATINGS
Incandescent - 1000W - 120VAC, 60HzLED/CFL - 450W - 120VAC, 60HzMark 10® - 1000VA - 120VAC, 60Hz
IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the Common (Line or Load) in both the dimmer wall box and remote wall box.
For non-standard wiring applications, referto Wire Connector and Conductor Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #182 - #12 w/ 1 or 2 #16 or #181 - #14 w/ 1 to 4 #16 or #182 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.COMBINATION CHART
• Pull off pre-cut insulation from dimmer leads.• Make sure that the ends of the wires from the wall box are straight
(cut if necessary).• Remove insulation from each wire in the wall box as shown.• For Single-Pole Application, go to Step 4a.• For 3-Way Matching Remote (w/LEDs) Application, go to Step 4b.
Step 4b
TOOLS NEEDED TO INSTALL YOUR DIMMERSlotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
MULTI-DEVICE APPLICATIONIn multi-dimmer installations, the reduction of the dimmer’s capacity may be required. Refer to the chart for maximum load per dimmer. NOTE: No derating is required for LED or CFL bulb applications.
If installing the device in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows:
INSTALLING DIMMER BY ITSELF OR WITH OTHER DEVICES
Changing the color of your Dimmer:Your device may include color options. To change color of the face proceed as follows:
1
2
Insert top tabs and press in bottom tabs to attach
Push in sides at bottom tabs and pull outward to release
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
Step 1
Step 2 Identifying your wiring application (most common):NOTE: If the wiring in your wall box does not resemble any of these configurations, consult an electrician.
2
43
1
Single Pole
1. Line (Hot)2. Neutral3. Ground4. Load
3-Way
1. Line or Load(see important instruction)2. Neutral3. Ground4. First Traveler – note color5. Second Traveler – note color
2
4
1
5
3
Cut (if necessary)
5/8" (1.6 cm) Strip Gage
(measure bare wire here)
Preparing and connecting wires:Pull off pre-cut insulation from dimmer leads. Make sure that the ends of the wires from the wall box are straight (cut if necessary). Remove insulation from each wire in the wall box as shown:
Step 3
Dimmer
InsulatingLabel
Black
Load
Hot (Black)Black
Line120 VAC,
60Hz
Neutral (White)
Red
Yellow/Red
White
White
GreenGround
White
Red
Green
Black 1
4
2
3
Insulating label:This wire is used in 3-way installations only.For single pole installations, do not remove insulating label.
Yellow/Red
Single Pole Wiring Application: Step 4a
MAXIMUM BULB WATTAGELow-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency of the transformer in the low-voltage lighting system. Transformer efficiencies will vary from different manufacturers; consider 80% efficient as average. Use the chart to determine maximum bulb wattage for typical transformer efficiency ratings.
MAXIMUM BULB WATTAGEMark 10® Powerline dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency of the Mark 10® Powerline ballast. The following table shows the maximum number of ballasts that can be connected to a single dimmer for different Mark 10® Powerline ballasts. Also note that the table shows maximum ballasts for multi-gang installations.
Lutron Tu-Wire®:To determine total ballast load, add the line current found on the ballast label for all ballasts in the circuit. This will indicate the total load for the control.
Remove all inner side sections
Do not remove outer side sections
Bend back and forth to remove side section
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than 2 Devices
700W
700VA
Two Devices
800W
800VA
Single
1000W
1000VA
Load
Incand
Mag LV
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
More than 2 Gang
560W
Rating
1000VA
Single
800W
Two Gang
640W
INTRODUCTION
Leviton’s Decora SmartTM Z-Wave® Dimmers are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. In a Z-Wave® network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. This dimmer is compatible with any Z-Wave® enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave® logo.WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH, DO NOT USE the remote for the control of high power heating appliances such as portable heaters. There can be some unexpected consequences if not used with care. For example, an empty coffee pot can be remotely turned on. If that should happen, your coffee pot could be damaged from overheating. If an electric heater is turned on by remote control while clothing is draped over it, a fire could result. This device will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury-vapor, sodium vapor and metal halide lamps.Decora® Smart Devices are ideal for living rooms, bedrooms, kitchens, dining rooms, home offices, outdoor lighting or anywhere full control of lighting is desired.
• Z-Wave Plus™ Certification - Increased communication range - Network Wide Inclusion - Support for beaming and secure commands - Over The Air (OTA) updates• Compatible with Leviton Vizia RF+ systems• Soft fade ON/OFF• ON/OFF LED and Brightness level LED • Three way communication • Ease of installation - No new wiring
FEATURES
WIRING DIMMER:Connect wires per WIRING DIAGRAM as follows:WARNING: CONNECT A MAGNETIC LOW-VOLTAGE DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC LOW-VOLTAGE TRANSFORMER.NOTE: The DZ1KD dimmer requires a Neutral wire connection.• Green or bare copper wire in wall box to Green dimmer lead.• Line Hot wall box wire to Black dimmer lead.• Load wall box wire to Red dimmer lead.• Line Neutral wall box wire to White dimmer lead.• Yellow/Red dimmer lead should have Red insulation label affixed. NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, use
electrical tape to cover.• Proceed to Step 5.
Cat. No. DZ1KD, 120V, For use with Advance Transformer 120V Mark 10® Powerline Electronic Ballasts
Max. # Ballasts/Dimmer for Multi-gang
Advance Mark 10®
Powerline Part No.
LampSingle Gang
Two Ganged
More than 2 Gang
REZ-2Q18-M2-LD
REZ-1T32
REZ-2Q26
REZ-1T32
REZ-1T42
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-1T32
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-2Q18-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2T42-M3-BS CFTR32W/GX24Q 13 10 8
CFTR32W/GX24Q 26 20 16
CFTR32W/GX24Q 26 20 16
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 32 25 20
CFTR26W/GX24Q 32 25 20
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 46 37 30
CFTR18W/GX24Q 46 37 30
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ18W/G24Q 23 18 15
CFQ18W/G24Q 46 37 30
CFQ18W/G24Q 46 37 30
CFM42W/GX24Q 20 16 13
CFM32W/GX24Q 26 20 16
CFM26W/GX24Q 17 13 11
CFM26W/GX24Q 32 25 20
151823CFM18W/GX24Q
WARNINGS AND CAUTIONS• Dimmer may feel warm to the touch during normal operation.• When magnetic low voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible transformer failure due to over
current, use a transformer that incorporates thermal protection or a fuse at the primary windings.• Recommended minimum wall box depth is 2-3/4".• Use this device with copper or copper clad wire only.• Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen fixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.• DO NOT mix bulb types when multiple bulbs are used with one dimmer. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance dimmer performance.• Leviton recommends Z-Wave® technology in residential installations up to 7,500 sq/ft. Metal junction boxes may adversely affect network coverage. Communication is designed to pass
through interior materials, exterior materials are designed to reflect RF energy and may prevent communication to detached buildings.• Z-Wave® networking technology is designed for distributed communication. Large clustering of communicating devices in a centralized location (ie. a closet) is not recommended.
WIRING DIMMER (wall box with load connection):Connect wires per WIRING DIAGRAM as follows:NOTE: The DZ1KD dimmer must be installed in a wall box that has a Load connection and a Neutral connection.• Green or bare copper wire in wall box to Green dimmer lead.• Load wall box wire identified (tagged) when removing old switch to
Red dimmer lead.• First Traveler Line Hot to Black dimmer lead.• Remove Red insulating label from Yellow/Red dimmer lead.• Second Traveler wall box wire (note color as above) to
Yellow/Red dimmer lead. This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to White dimmer lead.
WIRING MATCHING REMOTE (wall box with line hot connection):Connect wires per WIRING DIAGRAM as follows:NOTE: The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown.NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).• Green or bare copper wire in wall box to Green terminal screw.• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to Remote terminal marked "BK".• Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote must go to Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked "WH".• Proceed to Step 5.
Hot (Black)
Neutral (White)
DimmerMatching Remote (w/LEDs)
YL/RD
Red
Yellow/Red
WH BKBlack
Black
White
Line120VAC, 60Hz
GreenGround
GreenGround
WhiteLoad
3-Way Wiring with DD00R Matching Remote (w/LEDs) Application:
Matching Remote DimmerAdditional Neutral Wire
White
Red
Green
Black
1
2
3
Yellow/Red
4
5
1
2
3
4
5
WARNINGS AND CAUTIONS• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!• TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor, or a transformer operated appliance. • To be installed and/or used in accordance with electrical codes and regulations.• If you are unsure about any part of these instructions, consult an electrician.• Use with magnetic low voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers.• Use ONLY with the appropriate Advance Transformer 120V Mark 10® Powerline or Lutron Tu-Wire® electronic ballasts for controlling the specific fluorescent lamps in Fluorescent Mode.• When retrofitting Mark 10® Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start sockets to allow proper
dimmer operation and prevent damage to the dimmer ballast. Refer to the instructions provided with the ballast.• The Decora® DZ1KD dimmer is not compatible with standard 3-way or 4-way switches. It must be used with up to 4 Decora® Digital DD00R-DL remotes for multi-location dimming.• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.• Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
• Reorient or relocate the receiving Antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.
RATINGS
Incandescent - 1000W - 120VAC, 60HzLED/CFL - 450W - 120VAC, 60HzMark 10® - 1000VA - 120VAC, 60Hz
Agency Standing and Compliance Complies with UL 1472 CSA Certified (File #003413) NOM-ANCE Certified Complies with FCC Part 15, Class B Z-Wave Plus Certified
3-Way Wiring with DD00R Matching Remote (with LED) Application:
TOOLS NEEDED TO INSTALL YOUR DIMMER
Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
MULTI-DEVICE APPLICATIONIn multi-dimmer installations, the reduction of the dimmer’s capacity may be required. Refer to the chart for maximum load per dimmer. NOTE: No derating is required for LED or CFL bulb applications.
If installing the device in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows:
INSTALLING DIMMER BY ITSELF OR WITH OTHER DEVICES
If installing the device in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows:
INSTALLING DIMMER BY ITSELF OR WITH OTHER DEVICES
Changing the color of your Dimmer:Your device may include color options. To change color of the face proceed as follows:
1
2
Insert top tabs and press in bottom tabs to attach
Push in sides at bottom tabs and pull outward to release
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than 2 Devices
500W
Two Devices
500W
Single
600W
Load
Incand
INTRODUCTION
Leviton’s Decora SmartTM Z-Wave® Dimmers are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. In a Z-Wave® network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. This dimmer is compatible with any Z-Wave® enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave® logo.WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH DO NOT USE the remote for the control of high power heating appliances such as portable heaters. There can be some unexpected consequences if not used with care. For example, an empty coffee pot can be remotely turned on. If that should happen, your coffee pot could be damaged from overheating. If an electric heater is turned on by remote control while clothing is draped over it, a fire could result. This device will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury-vapor, sodium vapor and metal halide lamps.Decora SmartTM Devices are ideal for living rooms, bedrooms, kitchens, dining rooms, home offices, outdoor lighting or anywhere full control of lighting is desired.
• Z-Wave Plus™ Certification • Increased communication range • Network Wide Inclusion • Support for beaming and secure commands • Over The Air (OTA) updates• Compatible with Leviton vizia rf+ systems• Soft fade ON/OFF• ON/OFF LED and Brightness level LED • Three way communication • Ease of installation – No new wiring
FEATURES
WARNINGS AND CAUTIONS• Dimmer may feel warm to the touch during normal operation.• Recommended minimum wall box depth is 2-3/4".• Use this device with copper or copper clad wire only.• Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen fixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.• DO NOT mix bulb types when multiple bulbs are used with one dimmer. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance dimmer performance.• Leviton recommends Z-Wave® technology in residential installations up to 7,500 sq/ft. Metal junction boxes may adversely affect network coverage. Communication is designed to pass through
interior materials, exterior materials are designed to reflect RF energy and may prevent communication to detached buildings.• Z-Wave® networking technology is designed for distributed communication. Large clustering of communicating devices in a centralized location (ie. a closet) is not recommended.
Cut (if necessary)
5/8" (1.6 cm) Strip Gage
(measure bare wire here)
Preparing and connecting wires:Pull off pre-cut insulation from dimmer leads. Make sure that the ends of the wires from the wall box are straight (cut if necessary). Remove insulation from each wire in the wall box as shown:
Step 3
Back Wire Connection Back wire openings accept #14-12 AWG solid copper wire only.
• Make sure that the ends of the wires from the wall box are straight (cut if necessary).
• Remove insulation from each wire in the wall box as shown.• For Single-Pole Application, go to Step 4a.• For 3-Way Matching Remote (with LEDs) Application, go to Step 4b.
Side Wire Connection Side wire terminals accept #14-12 AWG solid copper wire only.
For non-standard wiring applications, referto Wire Connector and Conductor Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #182 - #12 w/ 1 or 2 #16 or #181 - #14 w/ 1 to 4 #16 or #182 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.COMBINATION CHART
WIRING DIMMER:Connect wires per WIRING DIAGRAM as follows:NOTE: The DZ6HD dimmer requires a neutral connection.• Green or bare copper wire in wall box to Green dimmer
terminal screw.• Line Hot wall box wire to Black dimmer terminal screw.• Load wall box wire to Red dimmer terminal screw.• Neutral wall box wire to White dimmer terminal screw.• Yellow/Red dimmer terminal screw should have Red insulation
label affixed. NOTE: If insulating label is not afficed to Yellow/Red dimmer
terminal screw, use electrical tape to cover.• Proceed to step 5.
Dimmer
InsulatingLabel
Black
Load
Hot (Black)BK
Line120 VAC,
60Hz
Neutral (White)
RD
WH
YL/RD
White
GreenGround
TerminalScrew marked
Black (BK)
TerminalScrew marked
Red (RD)Terminal Label:Use terminal for 3-way or more applications only.For single-pole applications, DO NOT remove label.
TerminalScrew marked
Yellow/Red(YL/RD)
4
BKWH
RDYL/RD
1
3
2
Single Pole Wiring Application: Step 4a Step 4b
WIRING DIMMER(wall box with load connection):Connect wires per WIRING DIAGRAM as follows:NOTE: The DZ6HD dimmer must be installed in a wall box that has a Load connection. The dimmer also requires a neutral connection.• Green or bare copper wire in wall box to Green terminal screw.• Load wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked "RD".• First Traveler Line Hot to dimmer terminal screw marked "BK".• Remove Red insulating label from terminal screw marked "YL/RD".• Second Traveler wall box wire (note color as above) to dimmer terminal
screw marked "YL/RD". This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD".
• Neutral wall box wire to White dimmer terminal screw.
WIRING MATCHING REMOTE (wall box with Line Hot connection):Connect wires per WIRING DIAGRAM as follows:NOTE: The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult an electrician.NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90m).• Green or bare copper wire in wall box to Green terminal screw.• Line Hot (common) wall box wire identified (tagged) when removing old
switch and First Traveler to remote terminal screw marked "BK".• Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD".
• Line Neutral wall box to remote terminal screw marked "WH".
NOTE: To synchronize LEDs between a Decora® digital remote and the Decora® DZ6HD dimmer, a dim up or dim down command must be pressed on the remote.
• Proceed to Step 5.
Hot (Black)
Neutral (White)
DimmerMatching Remote (w/LEDs)
YL/RD
RD
YL/RD
WH BKBK
Black
White
Line120VAC, 60Hz
GreenGround
GreenGround
WH
Load
DimmerMatching Remote (with LED)
TerminalScrew
markedBlack
(BK)
TerminalScrew marked
Red (RD)
TerminalScrew marked
White (WH)
TerminalScrew
markedYellow/
Red(YL/RD)
TerminalScrew marked
Red (RD)
3
5
Neutral to TerminalScrew marked
White (WH)
2
3
5
WHBK
RDYL/RD
BK
RDYL/RD 1
44
1
TerminalScrew
markedBlack
(BK)
TerminalScrew
markedYellow/
Red(YL/RD)
WH 2
WARNINGS AND CAUTIONS• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!• TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor, or a transformer operated appliance. • To be installed and/or used in accordance with electrical codes and regulations.• If you are unsure about any part of these instructions, consult an electrician.• Use with incandescent, or 120V halogen fixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers.• The Decora® DZ6HD dimmer is not compatible with standard 3-way or 4-way switches. It must be used with up to 4 Decora® Digital DD00R-DL remotes for multi-location dimming.• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.• Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
Step 1
IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the Common (Line or Load) in both the dimmer wall box and remote wall box.
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Identifying your wiring application (most common):NOTE: If the wiring in your wall box does not resemble any of these configurations, consult an electrician.
Step 2
2
43
1
Single Pole
1. Line (Hot)2. Neutral3. Ground4. Load
3-Way
1. Line or Load(see important instruction)2. Neutral3. Ground4. First Traveler – note color5. Second Traveler – note color
2
4
1
5
3
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
• Reorient or relocate the receiving Antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.
RATINGS
Incandescent - 600W - 120VAC, 60HzLED/CFL - 300W - 120VAC, 60Hz
3-Way Wiring with DD00R Matching Remote (with LED) Application:
TOOLS NEEDED TO INSTALL YOUR DIMMER
Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
MULTI-DEVICE APPLICATIONIn multi-dimmer installations, the reduction of the dimmer’s capacity may be required. Refer to the chart for maximum load per dimmer. NOTE: No derating is required for LED or CFL bulb applications.
If installing the device in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows:
INSTALLING DIMMER BY ITSELF OR WITH OTHER DEVICES
If installing the device in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows:
INSTALLING DIMMER BY ITSELF OR WITH OTHER DEVICES
Changing the color of your Dimmer:Your device may include color options. To change color of the face proceed as follows:
1
2
Insert top tabs and press in bottom tabs to attach
Push in sides at bottom tabs and pull outward to release
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than 2 Devices
500W
Two Devices
500W
Single
600W
Load
Incand
INTRODUCTION
Leviton’s Decora SmartTM Z-Wave® Dimmers are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. In a Z-Wave® network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. This dimmer is compatible with any Z-Wave® enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave® logo.WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH DO NOT USE the remote for the control of high power heating appliances such as portable heaters. There can be some unexpected consequences if not used with care. For example, an empty coffee pot can be remotely turned on. If that should happen, your coffee pot could be damaged from overheating. If an electric heater is turned on by remote control while clothing is draped over it, a fire could result. This device will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury-vapor, sodium vapor and metal halide lamps.Decora SmartTM Devices are ideal for living rooms, bedrooms, kitchens, dining rooms, home offices, outdoor lighting or anywhere full control of lighting is desired.
• Z-Wave Plus™ Certification • Increased communication range • Network Wide Inclusion • Support for beaming and secure commands • Over The Air (OTA) updates• Compatible with Leviton vizia rf+ systems• Soft fade ON/OFF• ON/OFF LED and Brightness level LED • Three way communication • Ease of installation – No new wiring
FEATURES
WARNINGS AND CAUTIONS• Dimmer may feel warm to the touch during normal operation.• Recommended minimum wall box depth is 2-3/4".• Use this device with copper or copper clad wire only.• Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen fixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.• DO NOT mix bulb types when multiple bulbs are used with one dimmer. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance dimmer performance.• Leviton recommends Z-Wave® technology in residential installations up to 7,500 sq/ft. Metal junction boxes may adversely affect network coverage. Communication is designed to pass through
interior materials, exterior materials are designed to reflect RF energy and may prevent communication to detached buildings.• Z-Wave® networking technology is designed for distributed communication. Large clustering of communicating devices in a centralized location (ie. a closet) is not recommended.
Cut (if necessary)
5/8" (1.6 cm) Strip Gage
(measure bare wire here)
Preparing and connecting wires:Pull off pre-cut insulation from dimmer leads. Make sure that the ends of the wires from the wall box are straight (cut if necessary). Remove insulation from each wire in the wall box as shown:
Step 3
Back Wire Connection Back wire openings accept #14-12 AWG solid copper wire only.
• Make sure that the ends of the wires from the wall box are straight (cut if necessary).
• Remove insulation from each wire in the wall box as shown.• For Single-Pole Application, go to Step 4a.• For 3-Way Matching Remote (with LEDs) Application, go to Step 4b.
Side Wire Connection Side wire terminals accept #14-12 AWG solid copper wire only.
For non-standard wiring applications, referto Wire Connector and Conductor Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #182 - #12 w/ 1 or 2 #16 or #181 - #14 w/ 1 to 4 #16 or #182 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.COMBINATION CHART
WIRING DIMMER:Connect wires per WIRING DIAGRAM as follows:NOTE: The DZ6HD dimmer requires a neutral connection.• Green or bare copper wire in wall box to Green dimmer
terminal screw.• Line Hot wall box wire to Black dimmer terminal screw.• Load wall box wire to Red dimmer terminal screw.• Neutral wall box wire to White dimmer terminal screw.• Yellow/Red dimmer terminal screw should have Red insulation
label affixed. NOTE: If insulating label is not afficed to Yellow/Red dimmer
terminal screw, use electrical tape to cover.• Proceed to step 5.
Dimmer
InsulatingLabel
Black
Load
Hot (Black)BK
Line120 VAC,
60Hz
Neutral (White)
RD
WH
YL/RD
White
GreenGround
TerminalScrew marked
Black (BK)
TerminalScrew marked
Red (RD)Terminal Label:Use terminal for 3-way or more applications only.For single-pole applications, DO NOT remove label.
TerminalScrew marked
Yellow/Red(YL/RD)
4
BKWH
RDYL/RD
1
3
2
Single Pole Wiring Application: Step 4a Step 4b
WIRING DIMMER(wall box with load connection):Connect wires per WIRING DIAGRAM as follows:NOTE: The DZ6HD dimmer must be installed in a wall box that has a Load connection. The dimmer also requires a neutral connection.• Green or bare copper wire in wall box to Green terminal screw.• Load wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked "RD".• First Traveler Line Hot to dimmer terminal screw marked "BK".• Remove Red insulating label from terminal screw marked "YL/RD".• Second Traveler wall box wire (note color as above) to dimmer terminal
screw marked "YL/RD". This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD".
• Neutral wall box wire to White dimmer terminal screw.
WIRING MATCHING REMOTE (wall box with Line Hot connection):Connect wires per WIRING DIAGRAM as follows:NOTE: The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult an electrician.NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90m).• Green or bare copper wire in wall box to Green terminal screw.• Line Hot (common) wall box wire identified (tagged) when removing old
switch and First Traveler to remote terminal screw marked "BK".• Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD".
• Line Neutral wall box to remote terminal screw marked "WH".
NOTE: To synchronize LEDs between a Decora® digital remote and the Decora® DZ6HD dimmer, a dim up or dim down command must be pressed on the remote.
• Proceed to Step 5.
Hot (Black)
Neutral (White)
DimmerMatching Remote (w/LEDs)
YL/RD
RD
YL/RD
WH BKBK
Black
White
Line120VAC, 60Hz
GreenGround
GreenGround
WH
Load
DimmerMatching Remote (with LED)
TerminalScrew
markedBlack
(BK)
TerminalScrew marked
Red (RD)
TerminalScrew marked
White (WH)
TerminalScrew
markedYellow/
Red(YL/RD)
TerminalScrew marked
Red (RD)
3
5
Neutral to TerminalScrew marked
White (WH)
2
3
5
WHBK
RDYL/RD
BK
RDYL/RD 1
44
1
TerminalScrew
markedBlack
(BK)
TerminalScrew
markedYellow/
Red(YL/RD)
WH 2
WARNINGS AND CAUTIONS• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!• TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor, or a transformer operated appliance. • To be installed and/or used in accordance with electrical codes and regulations.• If you are unsure about any part of these instructions, consult an electrician.• Use with incandescent, or 120V halogen fixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers.• The Decora® DZ6HD dimmer is not compatible with standard 3-way or 4-way switches. It must be used with up to 4 Decora® Digital DD00R-DL remotes for multi-location dimming.• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.• Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
Step 1
IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the Common (Line or Load) in both the dimmer wall box and remote wall box.
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Identifying your wiring application (most common):NOTE: If the wiring in your wall box does not resemble any of these configurations, consult an electrician.
Step 2
2
43
1
Single Pole
1. Line (Hot)2. Neutral3. Ground4. Load
3-Way
1. Line or Load(see important instruction)2. Neutral3. Ground4. First Traveler – note color5. Second Traveler – note color
2
4
1
5
3
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
• Reorient or relocate the receiving Antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.
RATINGS
Incandescent - 600W - 120VAC, 60HzLED/CFL - 300W - 120VAC, 60Hz
SINGLE POLE WIRING DIAGRAM THREE-WAY WIRING DIAGRAM
DZ6HD 600W Dimmer with Z-Wave Technology
Agency Standing and Compliance Complies with UL 1472 CSA Certified (File #003413) NOM-ANCE Certified Complies with FCC Part 15, Class B Z-Wave Plus Certified
SINGLE POLE WIRING DIAGRAM THREE-WAY WIRING DIAGRAM
DZ15S Switch with Z-Wave Technology
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
• Reorient or relocate the receiving Antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.
WARNINGS AND CAUTIONS• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!• To be installed and/or used in accordance with electrical codes and regulations.• If you are unsure about any part of these instructions, consult an electrician.• The Decora® DZ15S is not compatible with standard 3-way or 4-way switches.• Use only (1) Decora® DZ15S switch in a multi-location circuit with up to 9 coordinating remote switches (DD0SR-10), or up to 4 matching remote switches (DD0SR-DL).• Maximum wire length from switch to all installed remotes cannot exceed 300 ft (90m).
WARNINGS AND CAUTIONS • Recommended minimum wall box depth is 2-3/4".• Use this device with copper or copper clad wire only.• Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.• Leviton recommends Z-Wave® technology in residential installations up to 7,500 sq ft. Metal junction boxes may adversely affect network coverage. Communication is designed to pass
through interior materials, exterior materials are designed to reflect RF energy and may prevent communication to detached buildings.• Z-Wave® networking technology is designed for distributed communication. Large clustering of communicating devices in a centralized location (ie. a closet) is not recommended.
3-Way Wiring with DD0SR-10 Coordinating Remote (no LED) Application:
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
Identifying your wiring application (most common):NOTE: If the wiring in your wall box does not resemble any of these configurations, consult an electrician.
INSTALLING YOUR SWITCH
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Step 1
2
43
1
Single Pole
1. Line (Hot)2. Neutral3. Ground4. Load
2
543
1
3-Way
1. Line or Load (see important instruction)
2. Neutral3. Ground4. First Traveler – note color5. Second Traveler – note color
Step 2
TerminalScrew marked
Black (BK)
TerminalScrew marked
Red (RD)Terminal Label:Use terminal for 3-way or more applications only.For single-pole applications, DO NOT remove label.
TerminalScrew marked
White (WH)
TerminalScrew marked
Yellow/Red(YL/RD)
2
4
WHBK
RDYL/RD
1
3
Single Pole Wiring Application: Step 4a
WIRING SWITCH:Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal
screw.• Line Hot wall box wire to terminal screw marked "BK".• Load wall box wire to terminal screw marked "RD".• Line Neutral wall box wire to terminal screw marked "WH".• Switch terminal screw marked "YL/RD" should have Red
insulation label affixed. NOTE: If insulating label is not affixed to terminal screw
marked "YL/RD", use electrical tape to cover.• Proceed to Step 5.
Leviton’s Decora SmartTM Z-Wave® Devices are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. In a Z-Wave® network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. This switch is compatible with any Z-Wave® enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave® logo.WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH DO NOT USE the remote for the control of high power heating appliances such as portable heaters. There can be some unexpected consequences if not used with care. For example, an empty coffee pot can be remotely turned on. If that should happen, your coffee pot could be damaged from overheating. If an electric heater is turned on by remote control while clothing is draped over it, a fire could result. This device will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury-vapor, sodium vapor and metal halide lamps.Decora SmartTM Devices are ideal for living rooms, bedrooms, kitchens, dining rooms, home offices, outdoor lighting or anywhere full control of lighting is desired.
• Z-Wave Plus™ Certification - Increased communication range - Network Wide Inclusion - Support for beaming and secure commands - Over The Air (OTA) updates• Compatible with Leviton Vizia RF+ systems• Three way communication • Ease of installation - No new wiring
FEATURES
INTRODUCTION
SwitchCoordinating Remote (no LED)
TerminalScrew
markedBlack (BK)
TerminalScrew marked
Red (RD)
TerminalScrew marked
White (WH)
TerminalScrew
markedYellow/Red
(YL/RD)
2
4
TerminalScrew marked
Yellow/Red (YL/RD)
2
4
1
WHBK
RDYL/RD
WHBK
RDYL/RD
1
Neutral to TerminalScrew marked
White (WH)
3 3
5 5
TerminalScrew
markedBlack
(BK)
TerminalScrew
markedYellow/Red
(YL/RD)
GreenGround
GreenGround
Hot (Black)
Neutral (White)
Coordinating Remote (no LED)
YL/RD YL/RDRD
WH
RD
BK
Black
BKWH
White
Line120/277VAC
60Hz
(unused)
(unused)
Load
Switch
Step 4b
NOTE: The switch must be installed in a wall box that has a Line Hot and Neutral connection. The coordinating remote must be installed in a wall box with a Load connection and a Neutral connection. A Neutral wire to the coordinating remote needs to be added as shown. If you are unsure about any part of these instructions, consult an electrician. NOTE: Maximum wire length from switch to all installed remotes cannot exceed 300 ft (90 m).
WIRING SWITCH (wall box with line hot connection):Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal screw.• Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked "BK".• First Traveler wall box wire to terminal screw marked "RD"
(note wire color).• Remove Red insulating label from terminal screw marked "YL/RD".• Second Traveler wall box wire to terminal screw marked "YL/RD"
(note wire color). This traveler from the switch must go to the terminal screw on the remote marked "YL/RD".
• Line Neutral wall box wire to terminal screw marked "WH".
WIRING COORDINATING REMOTE (wall box with load connection):Connect wires per WIRING DIAGRAM as follows:NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws.• Green or bare copper wire in wall box to Green terminal screw.• Load wall box wire identified (tagged) when removing old switch to
First Traveler (note color as above).• Second Traveler wall box wire (note color as above) to terminal screw
marked "YL/RD". This traveler from the remote must go to the terminal screw on the switch marked "YL/RD".
• Remove White insulating label from terminal screw marked "WH".• Line Neutral wall box wire to terminal screw marked "WH".• Proceed to Step 5.
TOOLS NEEDED TO INSTALL YOUR SWITCH
Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
Changing the color of your Switch:Your switch includes three color options. The switch ships with the White frame attached. To change color of frame, proceed as follows:
1
2
Insert top tabs and press in bottom tabs to attach
Push in sides at bottom tabs and pull outward to release
Preparing and connecting wires:This switch can be wired using side wire terminal screws or through backwire openings. Choose appropriate wire stripping specifications accordingly.
IMPORTANT : For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the switch wall box and remote wall box.
Step 3
• Make sure that the ends of the wires from the wall box are straight (cut if necessary).
• Remove insulation from each wire in the wall box as shown.• For Single-Pole Application, go to Step 4a.• For 3-Way Coordinating Remote (no LED) Application, go to Step 4b.• For 3-Way Matching Remote (with LED) Application, go to Step 4c.
5/8" (1.6 cm)Strip Gage
(measure bare wire here)Cut
(if necessary)
Side Wire Connection Side wire terminals accept #14-12 AWG solid copper wire only.
Back Wire Connection Back wire openings accept #14-12 AWG solid copper wire only.
Hot (Black)
Neutral (White)
Load
Switch
BK
Black
White
RD
GreenGround
YL/RD Line120/277VAC,
60Hz Use terminal for3-way or moreapplications only.For single-poleapplications,DO NOT remove label.
WH
3-Way Wiring with DD0SR-DL Matching Remote (with LED) Application:
Step 4c
SwitchMatching Remote (with LED)
TerminalScrew
markedBlack
(BK)
TerminalScrew marked
Red (RD)
TerminalScrew marked
White (WH)
TerminalScrew
markedYellow/
Red(YL/RD)
TerminalScrew marked
Red (RD)
2
3
5
Neutral to TerminalScrew marked
White (WH)
2
3
5
WHBK
RDYL/RD
WHBK
RDYL/RD 1
44
1
TerminalScrew
markedBlack
(BK)
TerminalScrew
markedYellow/
Red(YL/RD)
Hot (Black)
Neutral (White)
Load
YL/RD YL/RDRD
BKBlack
White
Line 120/277 VAC
60Hz
WH BK WH
Matching Remote (with LED) Switch
GreenGround
GreenGround
RD(unused)
NOTE: The switch must be installed in a wall box that has a Load and Neutral connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be connected as shown. If you are unsure about any part of these instructions, consult an electrician.NOTE: Maximum wire length from switch to all installed remotes cannot exceed 300 ft (90 m).
WIRING MATCHING REMOTE (wall box with line hot connection):Connect wires per WIRING DIAGRAM as follows:NOTE: "RD" terminal on matching remote is unused. Tighten screw.• Green or bare copper wire in wall box to Green terminal screw.• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to Remote terminal marked BK.• Second Traveler wall box wire from switch to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote must go to Yellow/Red switch terminal screw.
• Line Neutral wall box to remote terminal screw marked "WH".
WIRING SWITCH (wall box with load connection):Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal screw.• Load wall box wire identified (tagged) when removing old switch to
Red terminal screw.• First Traveler Line Hot to Black terminal screw.• Remove Red insulating label from Yellow/Red terminal screw.• Second Traveler wall box wire (note color as above) to Yellow/Red
terminal screw. This traveler from the switch must go to the terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to White terminal screw.• Proceed to Step 5.
RATINGS
Incandescent - 1800W - 120VAC, 60HzLED/CFL - 5A, 600W - 120VAC, 60HzFluorescent - 15A - 120VAC, 60Hz 8A - 277VAC, 60HzResistive - 15A - 120VAC, 60HzMotor - 1/2 HP - 120VAC, 60Hz
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
• Reorient or relocate the receiving Antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.
WARNINGS AND CAUTIONS• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!• To be installed and/or used in accordance with electrical codes and regulations.• If you are unsure about any part of these instructions, consult an electrician.• The Decora® DZ15S is not compatible with standard 3-way or 4-way switches.• Use only (1) Decora® DZ15S switch in a multi-location circuit with up to 9 coordinating remote switches (DD0SR-10), or up to 4 matching remote switches (DD0SR-DL).• Maximum wire length from switch to all installed remotes cannot exceed 300 ft (90m).
WARNINGS AND CAUTIONS • Recommended minimum wall box depth is 2-3/4".• Use this device with copper or copper clad wire only.• Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.• Leviton recommends Z-Wave® technology in residential installations up to 7,500 sq ft. Metal junction boxes may adversely affect network coverage. Communication is designed to pass
through interior materials, exterior materials are designed to reflect RF energy and may prevent communication to detached buildings.• Z-Wave® networking technology is designed for distributed communication. Large clustering of communicating devices in a centralized location (ie. a closet) is not recommended.
3-Way Wiring with DD0SR-10 Coordinating Remote (no LED) Application:
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
Identifying your wiring application (most common):NOTE: If the wiring in your wall box does not resemble any of these configurations, consult an electrician.
INSTALLING YOUR SWITCH
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Step 1
2
43
1
Single Pole
1. Line (Hot)2. Neutral3. Ground4. Load
2
543
1
3-Way
1. Line or Load (see important instruction)
2. Neutral3. Ground4. First Traveler – note color5. Second Traveler – note color
Step 2
TerminalScrew marked
Black (BK)
TerminalScrew marked
Red (RD)Terminal Label:Use terminal for 3-way or more applications only.For single-pole applications, DO NOT remove label.
TerminalScrew marked
White (WH)
TerminalScrew marked
Yellow/Red(YL/RD)
2
4
WHBK
RDYL/RD
1
3
Single Pole Wiring Application: Step 4a
WIRING SWITCH:Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal
screw.• Line Hot wall box wire to terminal screw marked "BK".• Load wall box wire to terminal screw marked "RD".• Line Neutral wall box wire to terminal screw marked "WH".• Switch terminal screw marked "YL/RD" should have Red
insulation label affixed. NOTE: If insulating label is not affixed to terminal screw
marked "YL/RD", use electrical tape to cover.• Proceed to Step 5.
Leviton’s Decora SmartTM Z-Wave® Devices are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. In a Z-Wave® network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. This switch is compatible with any Z-Wave® enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave® logo.WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH DO NOT USE the remote for the control of high power heating appliances such as portable heaters. There can be some unexpected consequences if not used with care. For example, an empty coffee pot can be remotely turned on. If that should happen, your coffee pot could be damaged from overheating. If an electric heater is turned on by remote control while clothing is draped over it, a fire could result. This device will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury-vapor, sodium vapor and metal halide lamps.Decora SmartTM Devices are ideal for living rooms, bedrooms, kitchens, dining rooms, home offices, outdoor lighting or anywhere full control of lighting is desired.
• Z-Wave Plus™ Certification - Increased communication range - Network Wide Inclusion - Support for beaming and secure commands - Over The Air (OTA) updates• Compatible with Leviton Vizia RF+ systems• Three way communication • Ease of installation - No new wiring
FEATURES
INTRODUCTION
SwitchCoordinating Remote (no LED)
TerminalScrew
markedBlack (BK)
TerminalScrew marked
Red (RD)
TerminalScrew marked
White (WH)
TerminalScrew
markedYellow/Red
(YL/RD)
2
4
TerminalScrew marked
Yellow/Red (YL/RD)
2
4
1
WHBK
RDYL/RD
WHBK
RDYL/RD
1
Neutral to TerminalScrew marked
White (WH)
3 3
5 5
TerminalScrew
markedBlack
(BK)
TerminalScrew
markedYellow/Red
(YL/RD)
GreenGround
GreenGround
Hot (Black)
Neutral (White)
Coordinating Remote (no LED)
YL/RD YL/RDRD
WH
RD
BK
Black
BKWH
White
Line120/277VAC
60Hz
(unused)
(unused)
Load
Switch
Step 4b
NOTE: The switch must be installed in a wall box that has a Line Hot and Neutral connection. The coordinating remote must be installed in a wall box with a Load connection and a Neutral connection. A Neutral wire to the coordinating remote needs to be added as shown. If you are unsure about any part of these instructions, consult an electrician. NOTE: Maximum wire length from switch to all installed remotes cannot exceed 300 ft (90 m).
WIRING SWITCH (wall box with line hot connection):Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal screw.• Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked "BK".• First Traveler wall box wire to terminal screw marked "RD"
(note wire color).• Remove Red insulating label from terminal screw marked "YL/RD".• Second Traveler wall box wire to terminal screw marked "YL/RD"
(note wire color). This traveler from the switch must go to the terminal screw on the remote marked "YL/RD".
• Line Neutral wall box wire to terminal screw marked "WH".
WIRING COORDINATING REMOTE (wall box with load connection):Connect wires per WIRING DIAGRAM as follows:NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws.• Green or bare copper wire in wall box to Green terminal screw.• Load wall box wire identified (tagged) when removing old switch to
First Traveler (note color as above).• Second Traveler wall box wire (note color as above) to terminal screw
marked "YL/RD". This traveler from the remote must go to the terminal screw on the switch marked "YL/RD".
• Remove White insulating label from terminal screw marked "WH".• Line Neutral wall box wire to terminal screw marked "WH".• Proceed to Step 5.
TOOLS NEEDED TO INSTALL YOUR SWITCH
Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
Changing the color of your Switch:Your switch includes three color options. The switch ships with the White frame attached. To change color of frame, proceed as follows:
1
2
Insert top tabs and press in bottom tabs to attach
Push in sides at bottom tabs and pull outward to release
Preparing and connecting wires:This switch can be wired using side wire terminal screws or through backwire openings. Choose appropriate wire stripping specifications accordingly.
IMPORTANT : For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the switch wall box and remote wall box.
Step 3
• Make sure that the ends of the wires from the wall box are straight (cut if necessary).
• Remove insulation from each wire in the wall box as shown.• For Single-Pole Application, go to Step 4a.• For 3-Way Coordinating Remote (no LED) Application, go to Step 4b.• For 3-Way Matching Remote (with LED) Application, go to Step 4c.
5/8" (1.6 cm)Strip Gage
(measure bare wire here)Cut
(if necessary)
Side Wire Connection Side wire terminals accept #14-12 AWG solid copper wire only.
Back Wire Connection Back wire openings accept #14-12 AWG solid copper wire only.
Hot (Black)
Neutral (White)
Load
Switch
BK
Black
White
RD
GreenGround
YL/RD Line120/277VAC,
60Hz Use terminal for3-way or moreapplications only.For single-poleapplications,DO NOT remove label.
WH
3-Way Wiring with DD0SR-DL Matching Remote (with LED) Application:
Step 4c
SwitchMatching Remote (with LED)
TerminalScrew
markedBlack
(BK)
TerminalScrew marked
Red (RD)
TerminalScrew marked
White (WH)
TerminalScrew
markedYellow/
Red(YL/RD)
TerminalScrew marked
Red (RD)
2
3
5
Neutral to TerminalScrew marked
White (WH)
2
3
5
WHBK
RDYL/RD
WHBK
RDYL/RD 1
44
1
TerminalScrew
markedBlack
(BK)
TerminalScrew
markedYellow/
Red(YL/RD)
Hot (Black)
Neutral (White)
Load
YL/RD YL/RDRD
BKBlack
White
Line 120/277 VAC
60Hz
WH BK WH
Matching Remote (with LED) Switch
GreenGround
GreenGround
RD(unused)
NOTE: The switch must be installed in a wall box that has a Load and Neutral connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be connected as shown. If you are unsure about any part of these instructions, consult an electrician.NOTE: Maximum wire length from switch to all installed remotes cannot exceed 300 ft (90 m).
WIRING MATCHING REMOTE (wall box with line hot connection):Connect wires per WIRING DIAGRAM as follows:NOTE: "RD" terminal on matching remote is unused. Tighten screw.• Green or bare copper wire in wall box to Green terminal screw.• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to Remote terminal marked BK.• Second Traveler wall box wire from switch to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote must go to Yellow/Red switch terminal screw.
• Line Neutral wall box to remote terminal screw marked "WH".
WIRING SWITCH (wall box with load connection):Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal screw.• Load wall box wire identified (tagged) when removing old switch to
Red terminal screw.• First Traveler Line Hot to Black terminal screw.• Remove Red insulating label from Yellow/Red terminal screw.• Second Traveler wall box wire (note color as above) to Yellow/Red
terminal screw. This traveler from the switch must go to the terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to White terminal screw.• Proceed to Step 5.
RATINGS
Incandescent - 1800W - 120VAC, 60HzLED/CFL - 5A, 600W - 120VAC, 60HzFluorescent - 15A - 120VAC, 60Hz 8A - 277VAC, 60HzResistive - 15A - 120VAC, 60HzMotor - 1/2 HP - 120VAC, 60Hz
Agency Standing and Compliance Complies with UL 917 CSA Certified (File #003413) NOM-ANCE Certified Complies with FCC Part 15, Class B Z-Wave Plus Certified
Dimensional Drawings
SAO_10028REV MAR 2017
Leviton Manufacturing Co., Inc. Global Headquarters201 North Service Road, Melville, NY 11747-3138Tel: 1-800-323-8920 Fax: 1-800-832-9538Tech Line: (8:30AM-7:00PM ET Monday-Friday): 1-800-824-3005
Leviton Manufacturing Co., Inc. Energy Management, Controls and Automation4330 Michoud Blvd., New Orleans, Louisiana, 70129Tel: 1-504-736-9810 Fax: 1-504-253-2954
Visit our website at: leviton.com/emca©2017 Leviton Manufacturing Co., Inc. All rights reserved.
Ordering Information
Description Cat. No.
1000W Dimmer with Z-Wave Technology DZ1KD-1RZ
600W Dimmer with Z-Wave Technology DZ6HD-1RZ
15A Switch with Z-Wave Technology DZ15S-1RZ
Plug-in Outlet with Z-Wave Technology DZPA1-2BW
Plug-in Dimmer with Z-Wave Technology DZPD3-2BW
DZPA1 Plug-in Outlet with Z-Wave Technology
DZPD3 Plug-in Dimmer with Z-Wave Technology
1.95 (44.5)
0.66 (16.8)
1.15 (29.2)
2.97
(75.3)
0.47
(12.0)
2.39 (60.6)
0.69 (17.5)
0.43
(10.8)
2.97
(75.3)
0.84 (21.3)
1.56 (39.5)
1.95 (44.5)
0.66 (16.8)
1.15 (29.2)
2.97
(75.3)
0.47
(12.0)
2.39 (60.6)
0.69 (17.5)
0.43
(10.8)
2.97
(75.3)
0.84 (21.3)
1.56 (39.5)
Agency Standing and Compliance Complies with UL 917 CSA Certified (File #003413) NOM-ANCE Certified Z-Wave Plus Certified Complies with FCC Part 15, Class B
Agency Standing and Compliance Complies with UL 1472 CSA Certified (File #003413) NOM-ANCE Certified Z-Wave Plus Certified Complies with FCC Part 15, Class B