    Knowledge SharingKnowledge SharingSession OnSession On

    Connecting ElectricalConnecting Electrical

    DevicesDevices

    DEEPTHI P

  • 8/6/2019 DEEPTHI NAIR

    2/17

  • 8/6/2019 DEEPTHI NAIR

    3/17

    y Straight andAngled StrainReliefs

    y Light, Medium andHeavy-DutySaddle Bars

    y Conical Ring Style Backshells

    y Water-Tight Backshells

  • 8/6/2019 DEEPTHI NAIR

    4/17

    y When connecting Backshells and connectors, the backshell mustbe selected first and then the connector to prevent the connector

    from moving in the design.Connecting Single Insert Connectors

    y Step

    1. To connect two devices, click Connect ElectricalDevices.

    Connect Electrical Devices Disconnect Electrical Devices

  • 8/6/2019 DEEPTHI NAIR

    5/17

    2. Select a bundle connector plug in the geometry as the first2. Select a bundle connector plug in the geometry as the firstdevice. In this example, the connection points of both thedevice. In this example, the connection points of both thebundle connector and the equipment connector are displayedbundle connector and the equipment connector are displayedin green, indicating that they can be connected.in green, indicating that they can be connected.

    BacP- Backshell connection point

  • 8/6/2019 DEEPTHI NAIR

    6/17

    3. Select an equipment connector as the second device.

    If the equipment connector had already been usedor if no connection

    point had been definedthe connection points would be displayed as red.

    4. The harness connector is now aligned properly to theequipment connector.

    This is the same process used to place connectors into equipment ordisconnect panels.

  • 8/6/2019 DEEPTHI NAIR

    7/17

    Connecting Rectangular ConnectorsConnecting Rectangular Connectors

    Rectangular backshell or Strain Relief : Designed toallow the cables to move without cracking and/orbreaking away from the plug or connector thatconnects to an electrical outlet or a hardwaredevice.

    A rectangular connector or receptacleconsists of the following parts:

    y A connector shell,

    y One or many inserts,

  • 8/6/2019 DEEPTHI NAIR

    8/17

    Rectangular Connector

    Inserts

    Strain relief/ Back shell

    Shell

  • 8/6/2019 DEEPTHI NAIR

    9/17

    Dual Insert Rectangular ConnectorConnecting Dual Insert Connectors

    y Switch to Electrical Assembly Design .y ClickConnect Electrical Devices

    y Connect the first insert. Select the insertand then select the connector shell (select

    the CAV electrification).

    Cav-- Cavity

  • 8/6/2019 DEEPTHI NAIR

    10/17

    y Connect the second insert. Select the insert andthen select the connector shell (select the CAV

    electrification).

    y Select the backshell, and then select the

    connector.

    Back shell

    Insert

    Shell

  • 8/6/2019 DEEPTHI NAIR

    11/17

    y The dual insert rectangular connector andbackshell are now electrically connected

    y Shell DA6235PT

    y Backshell / Strainrelief DA6235PU

    Electrically Linked

  • 8/6/2019 DEEPTHI NAIR

    12/17

    1. To disconnect electrical devices, click DisconnectElectrical Devices .

    2.Select the first device to be disconnected.

    3. Select the second deviceor more specifically, the deviceyou wish to disconnect from the first device.

    4. The devices will disconnect, the electrical connection willbe deleted, and all assembly constraints will be eliminatedfrom the geometry and the specification tree.

    Disconnecting Electrical Devices

  • 8/6/2019 DEEPTHI NAIR

    13/17

    Apply Clocking Values toApply Clocking Values to BackshellsBackshells

    y The method of applying clocking to the backshells is by usingBOEBE5BSC(Backshell Clocker) to create angle constraints

    between the backshell and connector. This section describesusing Backshell clocker for creating the clocking anglesconstraints on the backshells

    y When electrically connecting the backshell to the connectorthe backshell must be selected first so that the Backshell

    Clocker tool will calculate the clocking angle correctly.y BSC-backshell Clocker (VER 2.4.0)

    y Every 1 hr is equal to 30 angle of clocking

  • 8/6/2019 DEEPTHI NAIR

    14/17

    UsingBackshellClocker

    BOEBE5BSC (Backshell Clocker) is an application that must be run in CATIA.

    BSC is used to record the clocking orientation of backshells to matingconnectors.

    y BSC creates angle constraints between the backshell and connector and records the clocking

    data into the in the properties windows description field of a backshell.

    Steps To Use Backshell Clocker1. Activate the GBN in the specification tree.

    2. Select the Backshell clocker function.

    3. Select a Back Shell to be clocked in BSC dialog.

  • 8/6/2019 DEEPTHI NAIR

    15/17

    y Select AllowableClocking Values forselectedbackshell

    ySelect the Apply button to clock the backshell

  • 8/6/2019 DEEPTHI NAIR

    16/17

    y Verify the values in the backshells properties window are set correctly

    y Update the model& verify the backshell is correctly clocked in the

    geometry

  • 8/6/2019 DEEPTHI NAIR

    17/17

    THANKYOU.