DR-010B MH-1 190 m³/h Dehumidifier Recusorb Built in humidistat Washable rotor No desiccant carry-over Self-regulating heater Easy to maintain Long lifetime With humidistat; only for installations where the unit is installed in the dehumidified room. Dehumidifying capacity at 20°C / 60%RH 0.5 kg/h Dry air flow Section of a dehumidifier rotor from Seibu Giken. The high number of channels means that moisture is adsorbed with extra efficiency!
Transcript
Page 1: Dehumidifier Recusorb DR-010B MH-1 · DR-010B MH-1 190 m³/h Dehumidifier Recusorb Built in humidistat Washable rotor ... Tolerance ISO 2768-1m t= D E F C 12 3 4 B A 1 2 3 5 C D 4

DR-010B MH-1

190 m³/h

Dehumidifier Recusorb

Built in humidistat

Washable rotor

No desiccant carry-over

Self-regulating heater

Easy to maintain

Long lifetime

With humidistat; only for installations where the unit is installed in the dehumidified room.

Dehumidifying capacity at 20°C / 60%RH 0.5 kg/hDry air flow

Section of a dehumidifier rotor from Seibu Giken. The high number of channels means that moisture is adsorbed with extra efficiency!

Page 2: Dehumidifier Recusorb DR-010B MH-1 · DR-010B MH-1 190 m³/h Dehumidifier Recusorb Built in humidistat Washable rotor ... Tolerance ISO 2768-1m t= D E F C 12 3 4 B A 1 2 3 5 C D 4

328

Thickness

Tolerance

ISO 2768-1m

t=

D

E

F

C

1 2 3 4

B

A

321 5

C

D

4 6 7

Dimension drawing

Format

Status

Construction

8

A

B

expr

essl

y pe

rmitt

ed b

y us

.

Title/Description

Drawn by

Approved by

Date

Date

2013-02-13

00+Rev

www.dst-sg.com

Dimensionsritning

Sheet/Sheet Weight (Kg)

Drawing no

DR-010B MH1

Scale

-

2013-02-13

Rev Part

2/2

Date

to a

ny o

ther

par

ty o

r use

d fo

r pur

pose

s no

t

A31:5DST04659

copi

ed, r

epro

duce

d, tr

ansm

itted

or c

omm

unic

ated

12

Designed by

Stefan O

Stefan O

00+

Material

This

doc

umen

t and

its

cont

ents

are

the

excl

usiv

epr

oper

ty o

f DST

Sei

bu G

iken

and

mus

t not

be

Seibu Giken DST AB+46 8 445 77 20

261,25

521

[mm]

Seibu Giken DST AB

Avestagatan 33 | SE-163 53 Spånga, Sweden

Tel +46 8 445 77 20 | Fax +46 8 445 77 39

www.dst-sg.com | [email protected]

16.

04

DR - 010B MH1

0,5

190

40

3 / 690

0,8

10

1252

1

261,25

328

COR

REC

TIO

N D

IAG

RAM

DIM

ENSI

ON

STE

CHN

ICAL

DAT

A

The dehumidifying capacity is estimated as the nominal capacity from above, multiplied by factor K from the correction diagram.

The temperature of the dry air at nominal air flows is calculated by:

tout = tin + ( K x 4) + 3

Subject to change without notice. Download installation drawing at www.dst-sg.com.

[mm]

Wet air out Ø80Dry air out Ø100

Process air in Ø100

Reg.airin Ø80

1 Valid for inlet conditions 20°C/60%RH. For other inlet conditions the capacity can be calculated by using the correction factor from the diagram shown below.2 Volume flow for density 1.20 kg/m3. Free blowing.3 The design of the PTC heater enables the power to be regulated by controlling the wet air flow.

Rotor

Process air

Fan

Heater

Dry air

Rotor motor

Wet air

GB

Dehumidifier model

Nominal capacity1 (kg/h)

Dry airflow2 (m3/h)

Wet air flow2 (m3/h)

Heater current3 (A/W)

Maximum electric consumption (kW)

Supply fuse 230V / 50Hz (A)

Weight (kg)

Moisture content (g/kg)

Enthalpy (kJ/kg)D

ry b

ulb


Recommended