+ All Categories
Home > Documents > DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

Date post: 30-Mar-2016
Category:
Upload: delonghi-australia
View: 254 times
Download: 11 times
Share this document with a friend
Description:
The DeLonghi fixed air conditioning product range for 2012 - 2013
Popular Tags:
12
De’Longhi Reverse Cycle Inverter Air Conditioning
Transcript
Page 1: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

De’Longhi Reverse CycleInverter Air Conditioning

Page 2: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013
Page 3: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

DE’LONGHI FIXED AIR INVERTER TECHNOLOGY

www.delonghi.com.au 1

Inverter technology has been designed to allow electronic control of the air conditioner and automatically adjust the cooling and heating capacity according to the space.

Inverter air conditioners offer maximum energy ef�ciency. The hermetic twin rotary compressor with BLD motor (permanent magnet) changes operating speeds based on requirements and the

set temperature. Therefore, the air conditioner always operates at its optimum capacity, reaching the ideal temperature and then maintaining it over time without thermal swings:

in fact, once the desired temperature has been reached, capacity is automatically adjusted to keep the temperature within +/– .05°C of the set point.

Page 4: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

2 www.delonghi.com.au

By using DC inverter technology, De'Longhi air conditioners guarantee the best comfort at all times, keeping the room temperature and humidity constant. The precise electronics deliver real energy savings, as power consumption is limited to effective requirements, particularly in periods of average and low thermal load (morning or evening). During the hotter and more humid times (middle of the day), the inverter air conditioners are especially effective, as they are designed to rapidly reach the ideal temperature, with the cooling capacity exceeding the rated output of the appliance.

The above graph clearly shows the operation of the Inverter throughout the day: while remaining on, the air conditioner operates in different modes, adapting to the outside climate conditions and consequently only consuming the energy required to maintain the desired temperature.

TIME OF DAY THE PROCESS IN ACTION

13:008:00 18:00

TEMPERATURE MAINTENANCE OF INVERTER SYSTEMS

8:00 13:00 18:00

Page 5: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

BIOSILVER TECHNOLOGY

THE PROCESS IN ACTION

An advanced �ltration system that effectively removes impurities and odours from the air. It is made up of speci�cally designed composite �lters. Firstly the air passes through a dust �lter which traps larger dust particles and atmospheric dust, which are drawn in from the air in the room.

The second process in the �ltering system is the silver Ion �lter. This �lter has an ef�cient antibacterial action which greatly reduces concentrations of irritants such as pollen

IT FEATURES HIGH ANTIBACTERIAL POWER THANKS TO THE SILVER IONS

IT REMOVES UNPLEASANT ODOURS ANDKEEPS THE AIR FRESH

ITS ELECTROSTATIC CHARGE TRAPS SMALLER DUST PARTICLES

FIL

TE

RE

DA

IR

PO

LLU

TE

D A

IR

IT TRAPSATMOSPHERIC DUST

IT FEATURES HIGH ANTIBACTERIAL POWER THANKS TO THE SILVER IONS

IT REMOVES UNPLEASANT ODOURS ANDKEEPS THE AIR FRESH

ITS ELECTROSTATIC CHARGE TRAPS SMALLER DUST PARTICLES

FIL

TE

RE

DA

IR

PO

LLU

TE

D A

IR

IT TRAPSATMOSPHERIC DUST

IT FEATURES HIGH ANTIBACTERIAL POWER THANKS TO THE SILVER IONS

IT REMOVES UNPLEASANT ODOURS ANDKEEPS THE AIR FRESH

ITS ELECTROSTATIC CHARGE TRAPS SMALLER DUST PARTICLES

FIL

TE

RE

DA

IR

PO

LLU

TE

D A

IR

IT TRAPSATMOSPHERIC DUST

IT FEATURES HIGH ANTIBACTERIAL POWER THANKS TO THE SILVER IONS

IT REMOVES UNPLEASANT ODOURS ANDKEEPS THE AIR FRESH

ITS ELECTROSTATIC CHARGE TRAPS SMALLER DUST PARTICLES

FIL

TE

RE

DA

IR

PO

LLU

TE

D A

IR

IT TRAPSATMOSPHERIC DUST

IT FEATURES HIGH ANTIBACTERIAL POWER THANKS TO THE SILVER IONS

IT REMOVES UNPLEASANT ODOURS ANDKEEPS THE AIR FRESH

ITS ELECTROSTATIC CHARGE TRAPS SMALLER DUST PARTICLES

FIL

TE

RE

DA

IR

PO

LLU

TE

D A

IR

IT TRAPSATMOSPHERIC DUST

and spores. The �lter is treated with small particles of silver which are able to block the multiplication of and kill any nearby airborne bacteria. The process will also remove unpleasant odours which keeps the air fresh.

The 3M �lter is electrostatically charged and retains the �nest dust particles. Working together the system will deliver a high �ltration capacity and return fresh �ltered air to the room.

IT TRAPS ATMOSPHERIC DUST

PO

LLU

TE

D A

IR

FIL

TE

RE

D A

IR

ITS ELECTROSTATIC TRAPS SMALLER DUST PARTICLES

IT REMOVES UNPLEASANT ODOURS AND KEEPS THE AIR FRESH

IT FEATURES HIGH ANTIBACTERIAL POWER THANKS TO THE SILVER IONS

www.delonghi.com.au 3

Page 6: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

!

Smart Mode creates ideal comfort conditions in the room.

The appliance automatically establishes whether to operate in Cooling, Heating, Fan Only, or Standby Mode, depending on environmental conditions. Fan Speed and Temperature are also automatically set in this mode.

I-Comfort is used to set the desired temperature at the exact point where the remote is located.

The temperature is measured by the sensor in the remote control, bypassing the temperature sensor inside the air conditioner unit.

By locating the sensor at the remote control location, and by reading the temperature every 10 minutes, the ambient room temperature is always at the perfect comfort level.

SMARTMODE

I-COMFORTTECHNOLOGY

4 www.delonghi.com.au

Page 7: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

www.delonghi.com.au 5

ADDITIONAL FEATURES OF REVERSE CYCLE SPLIT SYSTEM AIR CONDITIONERS

WARRANTY 5 years

DEHUMIDIFIER MODEFan speed is automatically set and up to 72L of excess moisture is removed per day

SMART MODEAutomatically chooses mode, fan speed, and temperature

TEMPERATURE – Decrease set temperature

iCOMFORT Sets room temperature at the location of the remote

TEMPERATURE +Increase set temperature

HEAT MODEProvides effective heating during winter months

MODESSwitch between operating modes

24 HOUR TIMER ONProgram the unit to turn on at any designated time

24 HOUR TIMER OFFSet 24 hour timer off

AUTO FANAutomatically selects the most suitable fan speed

FAN MODEFan speed can be set and unit will operate without air conditioning or heating

AIR CONDITIONING MODESet desired temperature and fan speed

SLEEP MODEGently changes temperature while you sleep for optimum comfort

TURBO/ BOOSTIncreases the fan speed to reach comfort level faster

!

INTELLIGENT REMOTE CONTROL

ON

MODE

OFF

!

+-

88°C

!

Page 8: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

6 www.delonghi.com.au

Page 9: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

www.delonghi.com.au 7

DEINVRC8AUPENERGY GUIDE Max. Cooling Capacity 8.00 kW Max. Heating Capacity 8.40 kW Energy Ef�ciency Ratio 3.30 Star Rating (Cooling) 1.5 Star Rating (Heating) 1.5

DEINVRC7AUPENERGY GUIDE Max. Cooling Capacity 7.00 kW Max. Heating Capacity 7.50 kW Energy Ef�ciency Ratio 3.30 Star Rating (Cooling) 1.5 Star Rating (Heating) 1.5

DEINVRC5AUPENERGY GUIDE Max. Cooling Capacity 5.20 kW Max. Heating Capacity 5.85 kW Energy Ef�ciency Ratio 3.30 Star Rating (Cooling) 1.5 Star Rating (Heating) 1.5

DEINVRC3AUPENERGY GUIDE Max. Cooling Capacity 3.50 kW Max. Heating Capacity 3.85 kW Energy Ef�ciency Ratio 3.80 Star Rating (Cooling) 2.5 Star Rating (Heating) 2.5

DEINVRC2AUPENERGY GUIDE Max. Cooling Capacity 2.60 kW Max. Heating Capacity 2.80 kW Energy Ef�ciency Ratio 3.84 Star Rating (Cooling) 2.5 Star Rating (Heating) 2.5

FEATURES APPLICABLE TO ALL MODELS I-Comfort Dehumidi�er Biosilver technology Sleep mode Smart mode Turbo power/boost 24 hour timer Auto fan function

INVERTER REVERSE CYCLE SPLIT SYSTEMS

Page 10: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

TECHNICAL SPECIFICATIONS INVERTER REVERSE CYCLE SPLIT SYSTEM AIR CONDITIONER

* Tested at 83.3% Part Load

** Tested at 100% Capacity

8 www.delonghi.com.au

MODEL DEINVRC8AUP DEINVRC7AUP DEINVRC5AUP DEINVRC3AUP DEINVRC2AUP

Cooling Capacity (kW) 8.00 7.00 5.20 3.50 2.60

Heating Capacity (kW) 8.40 7.50 5.85 3.85 2.80

Power Supply (Volts) 220 - 240 220 - 240 220 - 240 220 - 240 220 - 240

Phase/ Frequency (Ph/Hz) Single / 50 Single / 50 Single / 50 Single / 50 Single / 50

Power To Outdoor Outdoor Outdoor Indoor Indoor

** Running Current – Cooling (Amps) 11.42 9.96 7.82 4.33 3.25

** Running Current – Heating (Amps) 11.99 10.55 8.51 4.64 3.42

*E.E.R. 3.3 3.3 3.3 3.8 3.84

*C.O.P. 3.347 3.346 3.358 3.839 3.856

*A.E.E.R. 3.308 3.3 3.305 3.801 3.821

*A.C.O.P. 3.32 3.316 3.32 3.824 3.835

Energy Stars – Cooling 1.5 1.5 1.5 2.5 2.5

Energy Stars – Heating 1.5 1.5 1.5 2.5 2.5

Power Input – Cooling (kW) 2.46 2.14 1.59 0.98 0.73

Power Input – Heating (kW) 2.55 2.3 1.79 1.07 0.78

Moisture Removal (Dehumidi�er Mode L/hr)

3.0 2.9 2.1 1.0 0.9

Refrigerant Gas R410A R410A R410A R410A R410A

Pre Charged Refrigerant for 7.5m (kg)

2.4 1.8 1.2 1.26 0.87

Quantity of Refrigerant per meter of pipe over 7.5m (g/m)

50 50 20 20 20

Maximum Height between Int & Ext Unit (m)

10 10 10 10 10

Maximum Pipe Length between Int & Ext Unit (m)

30 30 25 20 15

Minimum Pipe Length between Int & Ext Unit (m)

7.5 5 5 5 5

Page 11: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

MODEL DEINVRC8AUP DEINVRC7AUP DEINVRC5AUP DEINVRC3AUP DEINVRC2AUP

Pipe Connection Method Pipe Flaring Pipe Flaring Pipe Flaring Pipe Flaring Pipe Flaring

Liquid Line Size (Inches) 1/4 1/4 1/4 1/4 1/4

Suction Line Size (Inches) 5/8 5/8 1/2 3/8 3/8

Pipe Tightening Torque - Liquid (Nm) 20 20 20 20 20

Pipe Tightening Torque - Gas (Nm) 65 65 35 35 35

Circuit Breaker 20 20 16 10 10

Minimum Cable Section (mm) 2.5 2.5 2.5 1.0 1.0

INDOOR UNIT

Maximum Air Flow (m3/hr) 1200 1200 850 600 580

Maximum Noise Level (dB(A)) 48 47 44 39 37

Dimensions - L x W x H (mm) 326 x 253 x 1178 326 x 253 x 1178 298 x 200 x 940 275 x 180 x 845 275 x 180 x 845

Net Weight (KG) 17.5 17.5 13 11 11

Head Type Closed Closed Closed Closed Closed

OUTDOOR UNIT

Maximum Noise Level (dB(A)) 59 59 56 52 50

Dimensions - L x W x H (mm) 790 x 427 x 980 790 x 427 x 980 700 x 396 x 955 592 x 320 x 848 540 x 320 x 776

Net Weight (KG) 70 65 44 36 32

Operation Temperatures Cooling – Max/Min (ºC)

21/43 21/43 21/43 21/43 21/43

Operation Temperatures Heating – Max/Min (ºC)

-5/24 -5/24 -5/24 -5/24 -5/24

5 YEAR WARRANTY YES YES YES YES YES

Page 12: DeLonghi Fixed Air Conditioning Brochure 2012 - 2013

Distributed by De’Longhi Australia Pty Ltd ABN 49 104 012 857 P.O. BOX 4540CASULA MALL NSW 2170

For Customer Care and Sales Information contact: Phone: 1800 126 659 Fax: 1800 007 289

Optional accessories can be purchased either directly from the point of purchase or by using the online accessory shop at: www.delonghi.com.au

To enquire about the warranty information on the products featured in this brochure, please visit: www.delonghi.com.au

DISCLAIMERS: Not all models available at time of print. Innovations and features depicted in this brochure are on specific models only. The product dimensions and specifications in this brochure apply to the specific products and models at the time of issue. These dimensions and specifications may change at any time. The photographs in this brochure are for illustrative purposes only.

Scan the QR code to view the Inverter Cooling range online


Recommended